Loading...
697 Marie Ct3830 PILOT KNOB ROAD I EAGAN, MN 55122-1810 (651) 675-5675 I TDD: (651) 454-8535 I FAX: (651) 675-5694 buildindinspectionsc citvofeagan.�gm Date: 2020 R (o ,22-20 el_ 165 3 7b ,- `1-73 76 fT(� /6537/ - /00.00 /LS37a �lf173."76 E AGA t OCT z [(12(1 r For Office use a„p•) Permit #: Permit Fee: gi o 73 76 Date Received: I (2f 22__ Staff: 3, C./ c -CO /453 73 IDENTIAL BUILDING PERMIT APPLICATION Site Address: 611-7 MArne Cow - Unit #: Resident/ Owner Name: "II) aflot ( c Phone: 612--S1°-3iq-7 L.tt66 W _ Q o IQq,cw SS123 Address /city /Zip: c� �l rl h ` ' ^ Applicant is: x Owner X Contractor S , 4 leLi m N t,e o 4o S ( I Type of Work LATEi gtO i� Description of work: IVev4 (t �4r� ConstructionCost: Multi -Family Building: (Yes / No > ) Contractor Company: I 0.- (J6+Netrl tHc Contact: 6 Address: "6"I6() ("Jahn hod ditvw City: 5 tcdr' State: NW Zip: 55.1v Phone: 612-710 • 3SR-7 Email: h ila.'1. A 04614 ' I/t6'1"rf. Coal License #: *it) C7 Lead Certificate #: If the project is exempt from lead certification, please explain why: In the last 12 months, Yes X No COMPLETE THIS AREA ONLY IF CONSTRUCTING A NEW BUILDING has the City of Eagan issued a permit for a similar plan based on a master plan? If yes, date and address of master plan: Licensed Plumber: Mechanical Contractor: Sewer & Water Contractor: Fire Suppression Contractor: / 1114. 1-ill 04t I /Phone: b S "' 9 5 21 37 -1 C-crr! 1-1 <<61irt Phone: 63 '' S k'2 — l 16 6 13S(-t? eDicAI/ r 1 Phone: 6/ 2- 3 6ct - Li / q7 Phone: NOTE: Plans and supporting documents that you submit are considered to be public information. Portions of the information may be classified as non-public if you provide specific reasons that would permit the City to conclude that they are trade secrets. You may subscribe to receive an electronic notification from the City of proposed ordinances by signing up for an email update on the City's website at www.citvofeaqan.com/subscribe. Exterior work authorized by a building permit issued in accordance with the Minnesota State Building Code must be completed within 180 days of permit issuance. CALL BEFORE YOU DIG. Call Gopher State One Call at (651) 454-0002 for protection against underground utility damage. Call 48 hours before you intend to dig to receive locates of underground utilities. www.aopherstateonecall.orq I hereby acknowledge that this information is complete and accurate; that the work will be in conformance with the ordinances and codes of the City of Eagan; that I understand this is not a permit, but only an application for a permit, and work is not to start without a permit; that the work will be in accordance with the approved plan in the case of work which requires a review and approva of plans. �ffa- Applicant's Printed Name x Applicant's Signature DO NOT WRITE BELOW THIS LINE 19Ri� SUB TYPES Foundation Single Family 7� Multi Fireplace Garage Deck 01 of _ Plex Lower Level WORK TYPES New 1 Addition Alteration Replace _ Retaining Wall DESCRIPTION Valuation Plan Review Interior Improvement Move Building Fire Repair _ Repair (25%_ 100%4) Census Code #of Units # of Buildings Type of Construction REQUIRED INSPECTIONS Footings (New Building) Footings (Deck) Footings (Addition) Foundation / Foundation Before Backfill Roof: _Ice & Water _Final Framing 30 Minutes )C 1 Hour Fireplace: y Rough In )(Air Test 46LFinal Insulation Sheathing Sheetrock 4 Porch (3-Season) Porch (4-Season) Porch (Screen/Gazebo/Pergola) Pool 11 ['Occupancy Code Edition Zoning Stories Square Feet Length Width Fire Walls Braced Walls Shower Pan R viewed By: Siding Reroof Windows Egress Window Exterior Alteration (Single Family) Exterior Alteration (Multi) Miscellaneous Accessory Building Demolish Building* Demolish Interior Demolish Foundation Water Damage *Demolition of entire building — give PCA handout to applicant MCES System TO SAC Units City Water Booster Pump 02, PRV Fire Suppression Required Meter Size: Final / C.O. Required Final / No C.O. Required HVAC Service Test Gas Line Air Test _ Hood Pool: _Footings _Air/Gas Tests _Final Drain Tile - .. Siding: _Stucco Lath ► Stone Lat_Brick _ EFIS Windows Retaining Wall: _ Footings _ Backfill _ Final Radon Control Fire Suppression: _Rough In _Final Erosion Control Other: , Building Inspector RESIDENTIAL FEES Base Fee Surcharge Plan Review MCES SAC City SAC Utility Connection Charge S&W Permit & Surcharge Treatment Plant Radio Meter Read Copies TOTAL n FtA /-0X/4, 0 ., fp) y q;;73 r 57 7 0 2.10y (`7 q New Construction Energy Code Compliance Certificate Per R401.3 Certificate. A building certificate shall be posted on or in the electrical distribution panel.4 Date Certificate Posted Mailing Address of the Dwelling or Dwelling Unit 697 Marie Ct City Eagan ^� e �r I;,� HEATING A AIR CONDITIONING Name of Residential Contractor Thorson Homes MN License Number {i• LB l7 THERMAL ENVELOPE RADON CONTROL SYSTEM Insulation Location (Total R-Value of all Types of Insulation Type. Check All That App y X Passive (No Fan) Non or Not Applicable Fiberglass, Blown N c0 N m N f5 o, m a LE Foam, Closed Cell Foam Open Cell Mineral Fiberboard Rigid, Extruded Polystyrene Rigid, Isocynurate Active (With tan and rweon fer or other system monitoring device) Location (or future location) of Fan: Other Please Describe Here Below Entire Slab Foundation Wall t 0 x Perimeter of Slab on Grade Rim Joist (1st Floor) Z 0,q x Rim Joist (2nd Floor+) 2-n 1.1 x Wall 20 x Ceiling, flat � 5C Ceiling, vaulted L{1 X Bay Windows or cantilevered areas X Floors over unconditioned area Describe other insulated areas Building envelope air tightness: Duct system air tightness: Windows 8 Doors Heating or Cooling Ducts Outside Conditioned Spaces Average U-Factor (excludes skylights and one door) U: al X Not applicable, all ducts located in conditioned space Solar Heat Gain Coefficient (SHGC): Nu R-value I MECHANICAL SYSTEMS Make up Air Select a Type Appliances Heating System Domestic Water Heater Cooling System X Not required per mech. code Fuel Type NATURAL GAS pm- GAS R410A Passive Manufacturer Carrier A(J0. Carrier Powered Model 59SC5B080 ,,11 n cW N Mc CA13NA036 Interlocked with exhaust device. Describe: Rating or Size Input in BTUS: 80,000 Capacity in Gallons: 50 Output in Tons: 3 Other, describe: Efficiency AFUE or HSPF% 95% SEER /EER 13 Location of duct or system: Residential Load Calculatii Heating Loss Heating Gain Cooling Load 60,527 32,075 2.67 Cfm's " round duct OR MECHANICAL VENTILATION SYSTEM " metal duct Describe any additional or combined heating or cooling systems if installed: (e.g. two furnaces or air source heat pump with gas back-up furnace): Select Type Combustion Air Select a Type Not required per mech. code X Passive Heat Recover Ventilator (HRV) Capacity in cfms: Low: High: Other, describe: X Energy Recover Ventilator (ERV) Capacity in cfms: Low: 78 High: 155 Location of duct or system: MECHANICAL ROOM Balanced Ventilation capacity in cfms: Location of fan(s), describe: I Cfm's Capacity continuous ventilation rate in cfms: 5 " round duct OR Total ventilation (intermittent + continuous) rate in cfms: 4 " metal duct Builders Associaton of Minnesota version 101014 Thorson Homes, 697 Marie Ct, Eagan 2015 Mechanical & Energy Code — Ventilation, Makeup, and Combustion Air Calculations Ventilation Quantity (Determine quantity by using Table R403.5.2 or Equation R403.5..2, 2015 Minnesota Energy Code) Square feet (Conditioned area including Basement — finished or unfinished) 3882 Total required ventilation 155 Number of bedrooms 4 Continuous ventilation 78 Directions - Determine the total and continuous ventilation rate by either using Table N1104.2 or equation 11-1. Insert the square footage, total required ventilation and continuous ventilation in the Mechanical Submittal form. The table and equation are below. Table R403.5.2 2015 Minnesota Energy Code Total and Continuous Ventilation Rates ('n cfm) Number of Bedrooms 1 2 3 4 5 6 Conditioned space (in sq. ft.) Total/ continuous Total/ continuous Total/ continuous Total/ continuous Total/ continuous Total/ continuous 1000-1500 60/40 75/40 90/45 105/53 120/60 135/68 1501-2000 70/40 85/43 100/50 115/58 130/65 145/73 2001-2500 80/40 95/48 110/55 125/63 140/70 155/78 2501-3000 90/45 105/53 120/60 135/68 150/75 165/83 3001-3500 100/50 115/58 130/65 145/73 160/80 175/88 3501-4000 110/55 125/63 140/70 155/78 170/85 185/93 4001-4500 120/60 135/68 150/75 165/83 180/90 195/98 4501-5000 130/65 145/73 160/80 175/88 190/95 205/103 5001-5500 140/70 155/78 170/85 185/93 200/100 215/108 5501-6000 150/75 165/;83 180/90 195/98 210/105 225/113 Equation R403.5.2 2015 Minnesota Energy Code (0.02 x square feet of conditioned space) + [15 x (number of bedrooms + 1)] = Total ventilation rate (cfm) Example: (0.02 x 3000) +[15 x (3 + 1)] = Total ventilation rate = 120 cfm Total ventilation — The mechanical ventilation system shall provide sufficient outdoor air to equal the total ventilation rate average for each one -hour period according to the above table or equation. For heat recovery ventilators (HRV) and energy recovery ventilators (ERV) the average hourly ventilation capacity must be determined in consideration of any reduction of exhaust or outdoor air intake, or both, for defrost or other equipment cycling. Continuous ventilation - A minimum of 50 percent of the total ventilation rate, but not less than 40 cfm, shall be provided, on a continuous rate average for each one -hour period. The portion of the mechanical ventilation system intended to be continuously may have automatic cycling controls providing the average flow rate for each hour is met. 1 Thorson Homes, 697 Marie Ct, Eagan Directions - In order to determine the makeup air for ventilation, Table 501.4.1 must be filled out (see below). For most new installations, column A will be appropriate, however, if kitchen hoods exceed 300 cfm, atmospherically vented appliances or solid fuel appliances are installed, use the appropriate column. Please note, if the makeup air quantity is negative, no additional makeup air will be required for ventilation, if the value is positive refer to Table 501.4.2 and size the opening. Transfer the cfm, size of opening and type (round, rectangular, flex or rigid) to the last line of section D. The ventilation make-up air supply must communicate with the exhaust appliances. Table 501.4.1, 2015 Minnesota Mechanical Code PROCEDURE TO DETERM NE MAKEUP AIR QUANITY FOR EXHAUST APPLIANCES IN DWELLING UNITS (Additional makeup air will be required for combustion appliances, see KAIR method for calculations) One or multiple power vent or direct vent appliances or no combustion appliances Column A One or multiple fan- assisted appliances and power vent or direct vent appliances Column B One atmospherically vented gas or oil appliance or one solid fuel appliance Column C Multiple atmospherically vented gas or oil appliances or solid fuel appliances Column D 1.Enter the Appropriate Column to Estimate House Infiltration a) pressure factor (cfm/sf) 0.15 0.09 0.06 0.03 b) conditioned floor area (sf) (including unfinished basements) 3882 Estimated House Infiltration (cfm): [1ax1bi 582 2. Exhaust Capacity a) clothes dryer (cfm) 135 135 135 135 b) 80% of largest exhaust rating (cfm); 100 (not applicable if recirculating system or if powered makeup air is electrically interlocked and match to exhaust) 80 _ c) 80% of next largest exhaust rating (cfm); 50 (not applicable if recirculating system or if powered makeup air Is electrically interlocked and matched to exhaust) 40 Total Exhaust Capacity (cfm); [2a + 2b +20 255 3. Makeup Air Quantity (cfm) a) total exhaust capacity (from above) 255 b) estimated house infiltration (from above) 582 Makeup Air Quantity (cfm); [3a — 3b[ (if value is negative, no makeup air is needed) -327 4. For makeup Air Opening Sizing, refer to Table 501.4.2 N/A A. B. C. D. Use this column if there are other than fan -assisted or atmospherically vented gas or oil appliance or if there are no combustion appliances. (Power vent and direct vent appliances may be used.) Use this column if there is one fan -assisted appliance per venting system. (Appliances other than atmospherically vented appliances may also be included.) Use this column if there is one atmospherically vented (other than fan -assisted) gas or oil appliance per venting system or one solid fuel appliance. Use this column If there are multiple atmospherically vented gas or oil appliances using a common vent or if there are atmospherically vented gas or oil appliances and solid fuel appliances. Be advised: 2015 Minnesota Mechanical Code, Section 505.2, Installation of exhaust hood systems capable of exhausting in excess of 400 cfm shall be provide with makeup air at a rate approximately equal to the exhaust air rate. Such makeup air systems shall be equipped with a means of closure and shall be automatically controlled to start and operate simultaneously with the exhaust system. 3 Thorson Homes, 697 Marie Ct, Eagan IFGC Appendix E, Worksheet E-1 Residential Combustion Air Calculation Method (for Furnace, Boiler, and/or Water Heater in the Same Space) Step 1: Complete vented combustion appliance information. Furnace/Boiler: Draft Hood Fan Assisted X Direct Vent Input: 80,000 Btu/hr _ (not fan -assisted & Power Vent Water Heater: _ Draft Hood _X Fan Assisted _ Direct Vent Input: 75,000 Btu/hr (not fan -assisted) & Power Vent Step 2: Calculate the volume of the Combustion Appliance Space (CAS) containing combustion appliances. The CAS includes all spaces connected to one another by code compliant openings. CAS volume: 1920 ft3 Step 3: Determine Air Changes per Hour (ACH)1 Default ACH values have been incorporated into Table E-1 for use with Method 4b (KAIR Method). If the year of construction or ACH is not known, use method 4a (Standard Method). Step 4: Determine Required Volume for Combustion Air. 4a. Standard Method Total Btu/hr input of all combustion appliances (DO NOT COUNT Input: 75,000 Btu/hr DIRECT VENT APPLIANCES) Use Standard Method column in Table E-1 to find Total Required TRV: 3750 ft3 Volume (TRV) If CAS Volume (from Step 2) is greater than TRV then no outdoor openings are needed. If CAS Volume (from Step 2) is less than TRV then go to STEP 5. 4b. Known Air Infiltration Rate (KAIR) Method Total Btu/hr input of all fan -assisted and power vent appliances Input: Btu/hr (DO NOT COUNT DIRECT VENT APPLIANCES) Use Fan -Assisted Appliances column in Table E-1 to find RVFA: ft3 Required Volume Fan Assisted (RVFA) Total Btu/hr input of all non -fan -assisted appliances Input: Btu/hr Use Non -Fan -Assisted Appliances column in Table E-1 to find RVNFA: ft3 Required Volume Non -Fan -Assisted (RVNFA) Total Required Volume (TRV) = RVFA + RVNFA TRV = + = ft3 If CAS Volume (from Step 2) is greater than TRV then no outdoor openings are needed. If CAS Volume (from Step 2) Is less than TRV then go to STEP 5. Step 5: Calculate the ratio of available interior volume to the total required volume. Ratio = CAS Volume (from Step 2) divided by TRV (from Step 4a or Step 4b) Ratio = 192Q / 3750 = .51 Step 6: Calculate Reduction Factor (RF). RF = 1 minus Ratio Ratio RF = 1 - .51 = .49 Step 7: Calculate single outdoor opening as if all combustion air is from outside. Total Btu/hr input of all Combustion Appliances in the same CAS Input: 75.000 Btu/hr (EXCEPT DIRECT VENT) Combustion Air Opening Area (CAOA): Total Btu/hr divided by 3000 Btu/hr per in2 CAOA = 75,000 / 3000 Btu/hr per inz = 25 in' Step 8: Calculate Minimum CAOA. Minimum CAOA = CAOA multiplied by RF Minimum CAOA = 25 x .49 = 12.25 in' Step 9: Calculate Combustion Air Opening Diameter (CAOD) CAOD = 1.13 multiplied by the square root of Minimum CAOA CAOD = 1.13 J Minimum CAOA = 3.96 in 1 If desired, ACH can be determined using ASHRAE calculation or blower door test. Follow procedures in Section G304. Although this worksheet, IFGC Appendix E, Worksheet E-1 and the following worksheet, IFGC Appendix E, Table E-1, is referenced in the 2015 Minnesota Fuel Gas Code, these worksheets were not included in the published copy. 4" Hard Pipe 5" Flex Pipe 5 Aspen Plan HVAC Load Calculations for Thorson Homes ipAsevart ,HVACRESIDENTIAL, HVAC LOADS Prepared By: Josh Schindele Flare Heating & Air Conditioning 9303 Plymouth Ave N Golden Valley, MN 55427 763-542-1166 Tuesday, October 13, 2020 Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. Rhvac - Resi ht Inc. I Flare Heating& A/C Inc. Golden Valle d MNIa9 55427-3700 ommercial HVAC Loads Elite SoftwarebeveloAspen1Pl n , YPa e2I Project Report General Project Information Project Title: Aspen Plan Designed By: Josh Project Date: Tuesday, October 13, 2020 Client Name: Thorson Homes Company Name: Flare Heating & Air Conditioning Company Representative: Josh Schindele Company Address: 9303 Plymouth Ave N Company City: Golden Valley, MN 55427 Company Phone: 763-542-1166 Company Fax: 763-542-3101 Company E-Mail Address: jschindele@flareheating.com Company Website: www.flareheating.com Design Data Reference City: Minneapolis/St. Paul AP, Minnesota Building Orientation: Front door faces East Daily Temperature Range: Medium Latitude: 44 Degrees Elevation: 834 ft. Altitude Factor: 0.970 Outdoor Outdoor Outdoor Indoor Indoor Grains Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference Winter: -16 -16.32 n/a n/a 72 n/a Summer: 93 71 34% 50% 72 22 Check Figures Total Building Supply CFM: 1,242 CFM Per Square ft.: 0.320 Square ft. of Room Area: 3,882 Square ft. Per Ton: 1,452 Volume (ft3): 30,293 Building Loads Total Heating Required Including Ventilation Air: 60,527 Btuh 60.527 MBH Total Sensible Gain: 26,871 Btuh 84 Total Latent Gain: 5,205 Btuh 16 3/0 Total Cooling Required Including Ventilation Air: 32,075 Btuh 2.67 Tons (Based On Sensible + Latent) 1 Notes Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. S:\FHDATA\PROJECTS\JOSH\Version6\Thorson Homes, Aspen Plan.rh9 Tuesday, October 13, 2020, 6:53 AM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Flare Heating & A/C Inc. Aspen Plan Golden Valley, MN 55427-3700 Page 3 Total Building Summary Loads f Component Area Sen Lat Sen Total Description Quan Loss Gain Gain Gain 2A-v-o: Glazing -Double pane low-e (e = 0.60), operable 441 11,254 0 9,793 9,793 window, vinyl frame, outdoor insect screen with 50% coverage, U-value 0.29, SHGC 0.22 11N: Door -Metal - Polystyrene Core, U-value 0.35 38 1,170 0 426 426 12F-0sw: Wall -Frame, R-21 insulation in 2 x 6 stud 2863 16,376 0 3,965 3,965 cavity, no board insulation, siding finish, wood studs, U-value 0.065 15B0-10sf-4: Wall -Basement, , R-10 board insulation to 330 2,006 0 248 248 floor, no interior finish, 4' floor depth, U-value 0.054, above grade U-value 0.083 15B0-10sf-8: Wall -Basement, , R-10 board insulation to 648 3,059 0 104 104 floor, no interior finish, 8' floor depth, U-value 0.05, above grade U-value 0.083 12D1-0sw: Wall -Frame, R-21 closed cell 2 lb. spray foam 160 1,070 0 310 310 insulation in 2 x 4 stud cavity, no board insulation, siding finish, wood studs, U-value 0.076 168-50: Roof/Ceiling-Under Attic with Insulation on Attic 1322 2,327 0 1,481 1,481 Floor (also use for Knee Walls and Partition Ceilings), Vented Attic, No Radiant Barrier, Dark Asphalt Shingles or Dark Metal, Tar and Gravel or Membrane, R-50 insulation, U-value 0.02 21A-20: Floor -Basement, Concrete slab, any thickness, 2 1280 3,041 0 0 0 or more feet below grade, no insulation below floor, any floor cover, shortest side of floor slab is 20' wide, U-value 0.027 20P-30: Floor -Over open crawl space or garage, Passive, 42 129 0 24 24 R-30 blanket insulation, any cover, U-value 0.035 Subtotals for structure: 40,432 0 16,351 16,351 People: 5 1,000 1,150 2,150 Equipment: 683 3,430 4,113 Lighting: 0 0 0 Ductwork: 0 0 0 0 Infiltration: Winter CFM: 198, Summer CFM: 166 18,557 2,394 3,711 6,105 Ventilation: Winter CFM: 78, Summer CFM: 78 1,538 1,128 367 1,495 Exhaust: Winter CFM: 230, Summer CFM: 230 AED Excursion: 0 0 1,861 1,861 Total Building Load Totals: 60,527 5,205 26,871 32,075 Check Figures 1 Total Building Supply CFM: 1,242 CFM Per Square ft.: 0.320 Square ft. of Room Area: 3,882 Square ft. Per Ton: 1,452 Volume (ft3): 30,293 wBuld►ng Loads.:., Total Heating Required Including Ventilation Air: 60,527 Btuh 60.527 MBH Total Sensible Gain: 26,871 Btuh 84 % Total Latent Gain: 5,205 Btuh 16 % Total Cooling Required Including Ventilation Air: 32,075 Btuh 2.67 Tons (Based On Sensible + Latent) Notes Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. S:\FHDATA\PROJECTS\JOSH\Version6\Thorson Homes, Aspen Plan.rh9 Tuesday, October 13, 2020, 6:53 AM Rhvac - Residential & Light Commercial HVAC Loads Flare Heating & A/C Inc. Golden Valley, MN 55427-3700 Building Pie Chart Building Loss 60,527 Btuh Building Gain 32,075 Btuh Wall 37%_- Elite Software Development, Inc. Aspen Plan Page 4 Floor 5% Ventilation 3% Roof 4% Wall 14% Glass 31% Floor 0% Roof 5% Infiltration 31% Door 2% Glass 19% AED Excursion 6% Ventilation 5% People 7% Door 1 _Infiltration 19% Equipment 13% S:\FHDATA\PROJECTS\JOSH\Version6\Thorson Homes, Aspen Plan.rh9 Tuesday, October 13, 2020, 6:53 AM City Inspection Dept. Copy City Forester Copy Applicant/Builder Copy /loS-376 EAGAN INDIVIDUAL RESIDENTIAL LOT TREE PRESERVATION PLAN SUMMARY CITY OF EAGAN FORESTRY DIVISION 651-675-5300 (BUILDER, PLEASE READ ATTACHMENTS) Development Schramm Meadows Lot Number Address Builder 6 697 Marie Ct Block Number 1 Thorson Homes Inc Phone Number: (612) 810-3597 Contact: Brian Thorson Tree Protection Requirements: Replacement Trees: Tree Protection Fencing Installed on Site Oak Tree Pruning (Immediately seal wounds during April 1 to July 31) Therapeutic Pruning Required Retaining Wall To Be Installed Other: X Not Required: No Mitigation is Required for this Application Attachments: Additional Notes: As Follows: Yes No (Refer to attached docrtrr ntgfjgt f�taORESTRY DIVISION R'VIEWED DATE (0-23 - 20zo HE-000.0 ADDRESS: 0.4\ `1' —" — N --��, -xV" � � —r � � � , xxu. 6 D -.9 9 938— \ \ \ 3 4 x 939.6 RIVE 0 • x941.2 x9413 DENOTES SET IRON PIPE MONUMENT DENOTES FOUND IRON PIPE MONUMENT DENOTES PROPOSED DRAINAGE DIRECTION • DENOTES SERVICE LOCATION O DENOTES WOOD HUB 000.0 DENOTES EXISTING ELEVATION ® DENOTES PROPOSED ELEVATION DENOTES HUB ELEVATION Bohlen Surveying & Associates 31432 Foliage Avenue Northfield, MN 55057 Phone: (507) 645.7768 ,meara bohlensurveyin9.com 1662 Cliff Road E Burnsville, MN 55337 A Phone: (952) 895-9212 Fax: (952) 895-9259 9444 7.R941.J\ \ x940.3�1. —93 --5 ti4 x9466 L CERTIFICATE OF SURVEY FOR THORSON HOMES 1"=20' LOT AREA = 13,080 SF HOUSE AREA = 1,911 SF NOTE.• ALL BUILDING DIMENSIONS ARE SHOWN TO OUTS/DE OF FOUNL477ON WALL DENOTES EXISTING CONTOUR DENOTES PROPOSED CONTOUR DENOTES BITUMINOUS SURFACE DENOTES CONCRETE SURFACE PROPOSED TOP OF WALL ELEV. = 948.2 PROPOSED GARAGE FLOOR ELEV. = 947.4 PROPOSED BASEMENT FLOOR ELEV. = 939.5 PROPERTY DESCRIPTION LOT 6, BLOCK7 SCHRAMMMEADOW9 CITYOF EAGAN, DAKOTA COUNTY, MINNESOTA. I HEREBY CERTIFY THAT THIS SURVEY WAS PREPARED BY ME OR UNDER MY DIRECT SUPERVISION AND THAT I AM A DULY LICENSED LAND SURVEYOR UNDER THE LAWS OF THE STATE OF MINNESOTA. DATE: 10-5-20 S.\Prniects\Fnnnn\soh rnmm mendnwa\dwn\'nth hlk1-7frt (-Iwo 10/5/2020 10- c1•00 AM CDT THOMAS J. O'MEARA, LAND SURVEYOR MINNESOTA LICENSE NO. 46167 697 Marie Ct Aerial Street Names en m f6 J Storm Basin en D c9 Sections Numbers TREE PRESERVATION PLAN REVIEW - INDIVIDUAL LOT EAGAN Date Building Permit Application Received 10/22/2020 Development Schramm Meadows Site Address 697 Marie Court Lot 6 Block 1 Builder Thorson Homes Contact Brian Thorson Telephone (612) -810-3597 E-mail brian@thorsonhomes.com Property/Lot Owner Name - Telephone - E-mail - Office Plan Review — Date 110/23/2020 Notes No Mitigation is required for this application Tree planting is encouraged and plantings must remain outside righ-of-way setback. Tree protection must remain in place until construction completion. Tree Preservation Data Original Plan Revised Plan Total Significant Woodland Area sq. ft sq. ft Total Significant Trees Woodland To Be Removed sq. ft sq. ft Trees To Be Removed Allowable Woodland Removal (20%) sq. ft sq. ft Allowable Tree Removal (20%) Required Mitigation YES (or) NO Calculated Mitigation Amounts Original Plan - Category A Category B Category C Revised Plan - Category A Category B Category C Site Inspection — Date 12/23/2020 Notes Site grading complete and House location staked Pe pre -i - -e4 -f-re •S p - = I o 441'L f - -s t p -o %c c -t —.. ►. -41 :3,4..-eit . G:\Forestry\TreePreservation\Tree Preservation Plan Review - Individual Lot.docx Original Tree Preservation Plan Approved — Date 5/18/20 Forwarded to Inspections — Date 10/23/2020 By By Discussion/Meetings with Builder/Owner - Notes Revised Tree Preservation Plan Approved — Date By Forwarded to Inspections — Date By Additional Field Inspections Date Notes Date Notes Date Notes Date Notes G:\Forestry\TreePreservation\Tree Preservation Plan Review - Individual Lot.docx Was the approved Tree Preservation Plan followed? YES (or) NO If no, was additional mitigation required? YES (or) NO (If yes, describe additional mitigation below) Final Site Inspection — Date Notes Additional Notes and/or aerial photo image (insert aerial image or draw map of site) G:\Forestry\TreePreservation\Tree Preservation Plan Review - Individual Lot.docx O z O ❑ O ❑ O ❑ O ❑ 0 ❑ O ❑ O ❑ O ❑ O ❑ O ❑ O ❑ O ❑ ❑❑❑❑❑❑❑❑❑❑❑❑ Add/Change PROPERTY LEGAL: LOT SURVEY CHECKLIST FOR RESIDENTIAL BUILDING PERMIT APPLICATION Lot 6, Block 1, Schramm Meadows DATE OF SURVEY: 10/5/2020 LATEST REVISION: DOCUMENT STANDARDS • Registered Land Surveyor signature and company • Building Permit Applicant • Legal description • Address • North arrow and scale • House type (rambler, walkout, split w/o, split entry, lookout, etc.) • Directional drainage arrows with slope/gradient % • Proposed/existing sewer and water services & invert elevation • Street name • Driveway (grade & width - in RNV and back of curb, 22' max.) • Lot Square Footage • Lot Coverage ELEVATIONS Existing 0 0 0 • Property corners O 0 0 • Top of curb at the driveway and property line extensions ❑ 0 0 • Elevations of any existing adjacent homes ❑❑ 0 ❑❑ • Adequate footing depth of structures due to adjacent utility trenches • Waterways (pond, stream, etc.) ❑ ❑ ❑ O ❑ ❑ O ❑ ❑ O ❑ ❑ O ❑ ❑ Yes ❑ 0 ❑ ❑ 0❑ ❑ 0❑ ❑ 0 ❑ ❑ 0❑ ❑ 0❑ No I — O ❑ ❑ O ❑❑ O ❑❑ O ❑❑ O ❑❑ O ❑❑ Proposed • Garage floor • Basement floor • Lowest exposed elevation (walkout/window) • Property corners • Front and rear of home at the foundation • PRV Required PONDING AREA (if applicable) • Easement line • NWL • HWL • Pond # designation • Emergency Overflow Elevation • Pond/Wetland buffer delineation • Shoreland Zoning Overlay District • Conservation Easements DIMENSIONS • Lot lines/Bearings & dimensions • Right-of-way and street width (to back of curb) • Proposed home dimensions including any proposed decks, overhangs greater than 2', porches, etc. (i.e. all structures requiring permanent footings) • Show all easements of record and any City utilities within those easements • Setbacks of proposed structure and sideyard setback of adjacent existing structures • Retaining wall requirements: Reviewed By: Dave Westermayer Date 10/26/2020 G:/1 Engineering/Forms/Cert. of Survey Checklist Fillable 6-28-19 .- A /05. y L/-) 8 ADDRESS: 447 Mole- at. 0.4 R R Ffp, INF* - 4 rUNAT 44.• Tx -- 941.2 T8.5X 938.0 x 937:9 • x 939.6 RIVE 7 144.2 - - 941.6 5 \ 'Z. 3:1 Maximum Slopes or i7 !aning Wall Will Be 1,;iequired _44 x -1/4.9446, x 941.2 x 937 9 co CY) 946.2 144.6 938 N78. IL., \ 41.6 eAszi7e447(_____ Se7Z?4Cir Z/Ne x94/.2 x941.3 LOT 6 x"zBLOCK 1 X 9382 x 9.39.2 Ito ol o'71:9f?c,y 19,5 41. CERTIFICATE OF SURVEY FOR THORSON HOMES N ISTALL PERIMETER CONTROL tr) x 941.2 x 940.1 x 93Z2 X 938.3 12.8 x 939.7 Dear /7.3 te) ezzo PROPOSED HOUSE FB/WO x 939*° x 943.9 ci 8.5 943. 946.6x CURB STOP 945.4 - x s,,945.0 ! 945.0 CONCRETE CURB & GU1TER GARAGE 1.98 x 939.4 x 941.3 OZs 5 1 x 93 .9 1 c27, 13) .0 CC) 11, 94.3.7 943.8 X 22 944.0x 11. o c‘i PROPOSED DRIVEWAY 5.3% 0 945..3 oll4r4 x 940.3 10 x941. ..cr) CO azz 944.1c 44.4 945.4 946. t 945.7 x 946.6 462 e5.7 70.27 MARIE COURT 58725 '28 nE CENTER UNE 0 DENOTES SET IRON PIPE MONUMENT • DENOTES FOUND IRON PIPE MONUMENT DENOTES PROPOSED DRAINAGE DIRECTION ---(000) 000.0 E = 000.0 DENOTES SERVICE LOCATION DENOTES WOOD HUB DENOTES EXISTING ELEVATION DENOTES PROPOSED ELEVATION DENOTES HUB ELEVATION Bohlen Surveying & Associates By 31432 Foliage Avenue Northfield, MN 55057 Phone: (507)645-7768 meara@bohlensurveying.com 3 A 1682 Cliff Road E. Date Burnsville, MN 55337 Phone: (952) 895-9212 Fax: (952) 895-9259 IENNED EAGAN ENGINEERING DEPT, x 93 X 3. 1" = 20' LOT AREA = 13,080 SF HOUSE AREA = 1,911 SF NOTE: ALL BUILDING DIMENSIONS ARE SHOWN TO OUTS/DE OF FOUNDATION WALL DENOTES EXISTING CONTOUR DENOTES PROPOSED CONTOUR DENOTES BITUMINOUS SURFACE DENOTES CONCRETE SURFACE PROPOSED TOP OF WALL ELEV. = 948.2 PROPOSED GARAGE FLOOR ELEV. = 947.4 PROPOSED BASEMENT FLOOR ELEV. = 939.5 PROPERTY DESCRIPTION LOT 6; BLOCK 1, SCHRAMM MEADOWS, CITY OF EAGAN, DAKOTA COUNTY, MINNESOTA. I HEREBY CERTIFY THAT THIS SURVEY WAS PREPARED BY ME OR UNDER MY DIRECT SUPERVISION AND THAT I AM A DULY LICENSED LAND SURVEYOR UNDER THE LAWS OF THE STATE OF MINNESOTA. DATE: 10-5-20 Thy (3Pluvta, c•\ Prniporfq\ Faaan\ THOMAS J. O'MEARA, LAND SURVEYOR MINNESOTA LICENSE NO. 46167 schramm meadows\ dwa \ lot6bIk1 cerLdwa 10/5/2020 10:59:00 AtimirpT PERMIT City of Eagan Permit Type:Plumbing Permit Number:EA169054 Date Issued:05/13/2021 Permit Category:ePermit Site Address: 697 Marie Ct Lot:6 Block: 1 Addition: Schramm Meadows PID:10-67620-01-060 Use: Description: Sub Type:Residential Work Type:Replace Description:Water Softener Meter Size Meter Type Manufacturer Serial Number Remote Number Line Size Comments:Carbon monoxide detectors are required within 10 feet of all sleeping room openings in residential homes (Minnesota State Building Code). Please call Building Inspections at (651) 675-5675 to schedule a final inspection. Fee Summary:PL - Permit Fee (WS &/or WH)$59.00 0801.4087 Surcharge-Fixed $1.00 9001.2195 $60.00 Total: I hereby acknowledge that I have read this application and state that the information is correct and agree to comply with all applicable State of Minnesota Statutes and City of Eagan Ordinances. Contractor:Owner:- Applicant - Daniel C & Megan J Bissell 697 Marie Ct Eagan MN 55123 (763) 234-0606 Milbert Company (culligan) 1801 50th St E Inver Grove Heights MN 55077 (651) 451-2241 Applicant/Permitee: Signature Issued By: Signature