IDENTIAL BUILDING PERMIT APPLICATION
Site Address: 611-7 MArne Cow -
Unit #:
Resident/
Owner
Name: "II) aflot ( c Phone: 612--S1°-3iq-7
L.tt66 W _ Q o IQq,cw SS123
Address /city /Zip: c� �l rl h
`
' ^
Applicant is: x Owner X Contractor S , 4 leLi m N t,e o 4o S ( I
Type of Work
LATEi gtO i�
Description of work: IVev4 (t �4r�
ConstructionCost: Multi -Family Building: (Yes / No > )
Contractor
Company: I 0.- (J6+Netrl tHc Contact: 6
Address: "6"I6() ("Jahn hod ditvw City: 5 tcdr'
State: NW Zip: 55.1v Phone: 612-710 • 3SR-7 Email: h ila.'1. A 04614 ' I/t6'1"rf. Coal
License #: *it) C7 Lead Certificate #:
If the project is exempt from lead certification, please explain why:
In the last 12 months,
Yes X No
COMPLETE THIS AREA ONLY IF CONSTRUCTING A NEW BUILDING
has the City of Eagan issued a permit for a similar plan based on a master plan?
If yes, date and address of master plan:
Licensed Plumber:
Mechanical Contractor:
Sewer & Water Contractor:
Fire Suppression Contractor:
/
1114. 1-ill 04t I /Phone: b S
"' 9 5 21 37
-1
C-crr! 1-1 <<61irt Phone: 63 '' S k'2 — l 16 6
13S(-t? eDicAI/ r 1 Phone: 6/ 2- 3 6ct - Li / q7
Phone:
NOTE: Plans and supporting documents that you submit are considered to be public information. Portions of the information may be
classified as non-public if you provide specific reasons that would permit the City to conclude that they are trade secrets.
You may subscribe to receive an electronic notification from the City of proposed ordinances by signing up for an email update on the City's
website at www.citvofeaqan.com/subscribe.
Exterior work authorized by a building permit issued in accordance with the Minnesota State Building Code must be completed within 180
days of permit issuance.
CALL BEFORE YOU DIG. Call Gopher State One Call at (651) 454-0002 for protection against underground utility damage. Call 48 hours before you
intend to dig to receive locates of underground utilities. www.aopherstateonecall.orq
I hereby acknowledge that this information is complete and accurate; that the work will be in conformance with the ordinances and codes of the City of
Eagan; that I understand this is not a permit, but only an application for a permit, and work is not to start without a permit; that the work will be in
accordance with the approved plan in the case of work which requires a review and approva of plans.
�ffa-
Applicant's Printed Name
x
Applicant's Signature
DO NOT WRITE BELOW THIS LINE
19Ri�
SUB TYPES
Foundation
Single Family
7� Multi
Fireplace
Garage
Deck
01 of _ Plex Lower Level
WORK TYPES
New
1 Addition
Alteration
Replace
_ Retaining Wall
DESCRIPTION
Valuation
Plan Review
Interior Improvement
Move Building
Fire Repair
_ Repair
(25%_ 100%4)
Census Code
#of Units
# of Buildings
Type of Construction
REQUIRED INSPECTIONS
Footings (New Building)
Footings (Deck)
Footings (Addition)
Foundation / Foundation Before Backfill
Roof: _Ice & Water _Final
Framing 30 Minutes )C 1 Hour
Fireplace: y Rough In )(Air Test 46LFinal
Insulation
Sheathing
Sheetrock
4
Porch (3-Season)
Porch (4-Season)
Porch (Screen/Gazebo/Pergola)
Pool
11 ['Occupancy
Code Edition
Zoning
Stories
Square Feet
Length
Width
Fire Walls
Braced Walls
Shower Pan
R viewed By:
Siding
Reroof
Windows
Egress Window
Exterior Alteration (Single Family)
Exterior Alteration (Multi)
Miscellaneous
Accessory Building
Demolish Building*
Demolish Interior
Demolish Foundation
Water Damage
*Demolition of entire building — give PCA handout to applicant
MCES System
TO SAC Units
City Water
Booster Pump
02, PRV
Fire Suppression Required
Meter Size:
Final / C.O. Required
Final / No C.O. Required
HVAC Service Test Gas Line Air Test _ Hood
Pool: _Footings _Air/Gas Tests _Final
Drain Tile - ..
Siding: _Stucco Lath ► Stone Lat_Brick _ EFIS
Windows
Retaining Wall: _ Footings _ Backfill _ Final
Radon Control
Fire Suppression: _Rough In _Final
Erosion Control
Other:
, Building Inspector
RESIDENTIAL FEES
Base Fee
Surcharge
Plan Review
MCES SAC
City SAC
Utility Connection Charge
S&W Permit & Surcharge
Treatment Plant
Radio Meter Read
Copies
TOTAL
n
FtA
/-0X/4, 0
., fp)
y q;;73
r 57
7 0
2.10y (`7
q
New Construction Energy Code Compliance Certificate
Per R401.3 Certificate. A building certificate shall be posted on or in the electrical distribution
panel.4
Date Certificate Posted
Mailing Address of the Dwelling or Dwelling Unit
697 Marie Ct
City
Eagan
^� e �r
I;,�
HEATING A AIR CONDITIONING
Name of Residential Contractor
Thorson Homes
MN License Number
{i• LB l7
THERMAL ENVELOPE
RADON CONTROL SYSTEM
Insulation Location
(Total R-Value of all Types of
Insulation
Type. Check All That App y
X
Passive (No Fan)
Non or Not Applicable
Fiberglass, Blown
N
c0
N
m
N
f5
o,
m
a
LE
Foam, Closed Cell
Foam Open Cell
Mineral Fiberboard
Rigid, Extruded Polystyrene
Rigid, Isocynurate
Active (With tan and rweon fer or other
system monitoring device)
Location (or future location) of Fan:
Other Please Describe Here
Below Entire Slab
Foundation Wall
t 0
x
Perimeter of Slab on Grade
Rim Joist (1st Floor)
Z 0,q
x
Rim Joist (2nd Floor+)
2-n 1.1
x
Wall
20
x
Ceiling, flat
�
5C
Ceiling, vaulted
L{1
X
Bay Windows or cantilevered areas
X
Floors over unconditioned area
Describe other insulated areas
Building envelope air tightness:
Duct system air tightness:
Windows 8 Doors
Heating or Cooling Ducts Outside Conditioned Spaces
Average U-Factor (excludes skylights and one door) U:
al
X
Not applicable, all ducts located in conditioned space
Solar Heat Gain Coefficient (SHGC):
Nu
R-value
I MECHANICAL SYSTEMS
Make up Air Select a Type
Appliances
Heating System
Domestic Water
Heater
Cooling System
X
Not required per mech. code
Fuel Type
NATURAL GAS
pm- GAS
R410A
Passive
Manufacturer
Carrier
A(J0.
Carrier
Powered
Model
59SC5B080
,,11 n
cW N Mc
CA13NA036
Interlocked with exhaust device.
Describe:
Rating or Size
Input in
BTUS:
80,000
Capacity
in Gallons:
50
Output
in Tons:
3
Other, describe:
Efficiency
AFUE or
HSPF%
95%
SEER
/EER
13
Location of duct or system:
Residential Load Calculatii
Heating Loss
Heating Gain
Cooling Load
60,527
32,075
2.67
Cfm's
" round duct OR
MECHANICAL VENTILATION SYSTEM
" metal duct
Describe any additional or combined heating or cooling systems if installed: (e.g. two furnaces or air
source heat pump with gas back-up furnace):
Select Type
Combustion Air Select a Type
Not required per mech. code
X
Passive
Heat Recover Ventilator (HRV) Capacity in cfms:
Low:
High:
Other, describe:
X
Energy Recover Ventilator (ERV) Capacity in cfms:
Low:
78
High:
155
Location of duct or system:
MECHANICAL ROOM
Balanced Ventilation capacity in cfms:
Location of fan(s), describe: I
Cfm's
Capacity continuous ventilation rate in cfms:
5
" round duct OR
Total ventilation (intermittent + continuous) rate in cfms:
4
" metal duct
Builders Associaton of Minnesota version 101014
Thorson Homes, 697 Marie Ct, Eagan
2015 Mechanical & Energy Code — Ventilation, Makeup, and Combustion Air
Calculations
Ventilation Quantity
(Determine quantity by using Table R403.5.2 or Equation R403.5..2, 2015 Minnesota Energy Code)
Square feet (Conditioned area including
Basement — finished or unfinished)
3882
Total required ventilation
155
Number of bedrooms
4
Continuous ventilation
78
Directions - Determine the total and continuous ventilation rate by either using Table N1104.2 or equation 11-1.
Insert the square footage, total required ventilation and continuous ventilation in the Mechanical Submittal form.
The table and equation are below.
Table R403.5.2 2015 Minnesota Energy Code
Total and Continuous Ventilation Rates ('n cfm)
Number of Bedrooms
1
2
3
4
5
6
Conditioned space (in
sq. ft.)
Total/
continuous
Total/
continuous
Total/
continuous
Total/
continuous
Total/
continuous
Total/
continuous
1000-1500
60/40
75/40
90/45
105/53
120/60
135/68
1501-2000
70/40
85/43
100/50
115/58
130/65
145/73
2001-2500
80/40
95/48
110/55
125/63
140/70
155/78
2501-3000
90/45
105/53
120/60
135/68
150/75
165/83
3001-3500
100/50
115/58
130/65
145/73
160/80
175/88
3501-4000
110/55
125/63
140/70
155/78
170/85
185/93
4001-4500
120/60
135/68
150/75
165/83
180/90
195/98
4501-5000
130/65
145/73
160/80
175/88
190/95
205/103
5001-5500
140/70
155/78
170/85
185/93
200/100
215/108
5501-6000
150/75
165/;83
180/90
195/98
210/105
225/113
Equation R403.5.2 2015 Minnesota Energy Code
(0.02 x square feet of conditioned space) + [15 x (number of bedrooms + 1)] = Total ventilation rate (cfm)
Example: (0.02 x 3000) +[15 x (3 + 1)] = Total ventilation rate = 120 cfm
Total ventilation — The mechanical ventilation system shall provide sufficient outdoor air to equal the total
ventilation rate average for each one -hour period according to the above table or equation. For heat recovery
ventilators (HRV) and energy recovery ventilators (ERV) the average hourly ventilation capacity must be
determined in consideration of any reduction of exhaust or outdoor air intake, or both, for defrost or other
equipment cycling.
Continuous ventilation - A minimum of 50 percent of the total ventilation rate, but not less than 40 cfm, shall be
provided, on a continuous rate average for each one -hour period. The portion of the mechanical ventilation
system intended to be continuously may have automatic cycling controls providing the average flow rate for each
hour is met.
1
Thorson Homes, 697 Marie Ct, Eagan
Directions - In order to determine the makeup air for ventilation, Table 501.4.1 must be filled out (see below). For
most new installations, column A will be appropriate, however, if kitchen hoods exceed 300 cfm, atmospherically
vented appliances or solid fuel appliances are installed, use the appropriate column. Please note, if the makeup
air quantity is negative, no additional makeup air will be required for ventilation, if the value is positive refer to
Table 501.4.2 and size the opening. Transfer the cfm, size of opening and type (round, rectangular, flex or rigid)
to the last line of section D. The ventilation make-up air supply must communicate with the exhaust appliances.
Table 501.4.1, 2015 Minnesota Mechanical Code
PROCEDURE TO DETERM NE MAKEUP AIR QUANITY FOR EXHAUST APPLIANCES IN DWELLING UNITS
(Additional makeup air will be required for combustion appliances, see KAIR method for calculations)
One or multiple power
vent or direct vent
appliances or no
combustion appliances
Column A
One or multiple fan-
assisted appliances
and power vent or
direct vent appliances
Column B
One atmospherically
vented gas or oil
appliance or one solid
fuel appliance
Column C
Multiple
atmospherically
vented gas or oil
appliances or solid
fuel appliances
Column D
1.Enter the Appropriate Column to Estimate House Infiltration
a) pressure factor
(cfm/sf)
0.15
0.09
0.06
0.03
b) conditioned floor area (sf)
(including unfinished basements)
3882
Estimated House Infiltration (cfm):
[1ax1bi
582
2. Exhaust Capacity
a) clothes dryer (cfm)
135
135
135
135
b) 80% of largest exhaust rating
(cfm); 100
(not applicable if recirculating
system or if powered makeup air is
electrically interlocked and match to
exhaust)
80
_
c) 80% of next largest exhaust
rating (cfm); 50
(not applicable if recirculating
system or if powered makeup air Is
electrically interlocked and matched
to exhaust)
40
Total Exhaust Capacity (cfm);
[2a + 2b +20
255
3. Makeup Air Quantity (cfm)
a) total exhaust capacity (from
above)
255
b) estimated house infiltration (from
above)
582
Makeup Air Quantity (cfm);
[3a — 3b[
(if value is negative, no makeup air
is needed)
-327
4. For makeup Air Opening Sizing,
refer to Table 501.4.2
N/A
A.
B.
C.
D.
Use this column if there are other than fan -assisted or atmospherically vented gas or oil appliance or if there are no combustion
appliances. (Power vent and direct vent appliances may be used.)
Use this column if there is one fan -assisted appliance per venting system. (Appliances other than atmospherically vented appliances
may also be included.)
Use this column if there is one atmospherically vented (other than fan -assisted) gas or oil appliance per venting system or one solid
fuel appliance.
Use this column If there are multiple atmospherically vented gas or oil appliances using a common vent or if there are
atmospherically vented gas or oil appliances and solid fuel appliances.
Be advised: 2015 Minnesota Mechanical Code, Section 505.2, Installation of exhaust hood systems capable of
exhausting in excess of 400 cfm shall be provide with makeup air at a rate approximately equal to the exhaust air
rate. Such makeup air systems shall be equipped with a means of closure and shall be automatically controlled
to start and operate simultaneously with the exhaust system.
3
Thorson Homes, 697 Marie Ct, Eagan
IFGC Appendix E, Worksheet E-1
Residential Combustion Air Calculation Method
(for Furnace, Boiler, and/or Water Heater in the Same Space)
Step 1: Complete vented combustion appliance information.
Furnace/Boiler:
Draft Hood Fan Assisted X Direct Vent Input: 80,000 Btu/hr
_
(not fan -assisted & Power Vent
Water Heater:
_ Draft Hood _X Fan Assisted _ Direct Vent Input: 75,000 Btu/hr
(not fan -assisted) & Power Vent
Step 2: Calculate the volume of the Combustion Appliance Space (CAS) containing combustion appliances.
The CAS includes all spaces connected to one another by code compliant openings. CAS volume: 1920
ft3
Step 3: Determine Air Changes per Hour (ACH)1
Default ACH values have been incorporated into Table E-1 for use with Method 4b (KAIR Method). If the year
of construction or ACH is not known, use method 4a (Standard Method).
Step 4: Determine Required Volume for Combustion Air.
4a. Standard Method
Total Btu/hr input of all combustion appliances (DO NOT COUNT Input: 75,000 Btu/hr
DIRECT VENT APPLIANCES)
Use Standard Method column in Table E-1 to find Total Required TRV: 3750 ft3
Volume (TRV)
If CAS Volume (from Step 2) is greater than TRV then no outdoor openings are needed.
If CAS Volume (from Step 2) is less than TRV then go to STEP 5.
4b. Known Air Infiltration Rate (KAIR) Method
Total Btu/hr input of all fan -assisted and power vent appliances Input: Btu/hr
(DO NOT COUNT DIRECT VENT APPLIANCES)
Use Fan -Assisted Appliances column in Table E-1 to find RVFA: ft3
Required Volume Fan Assisted (RVFA)
Total Btu/hr input of all non -fan -assisted appliances Input: Btu/hr
Use Non -Fan -Assisted Appliances column in Table E-1 to find RVNFA: ft3
Required Volume Non -Fan -Assisted (RVNFA)
Total Required Volume (TRV) = RVFA + RVNFA TRV = + = ft3
If CAS Volume (from Step 2) is greater than TRV then no outdoor openings are needed.
If CAS Volume (from Step 2) Is less than TRV then go to STEP 5.
Step 5: Calculate the ratio of available interior volume to the total required volume. Ratio = CAS Volume (from
Step 2) divided by TRV (from Step 4a or Step 4b)
Ratio = 192Q / 3750 = .51
Step 6: Calculate Reduction Factor (RF).
RF = 1 minus Ratio Ratio RF = 1 - .51 = .49
Step 7: Calculate single outdoor opening as if all combustion air is from outside.
Total Btu/hr input of all Combustion Appliances in the same CAS Input: 75.000 Btu/hr
(EXCEPT DIRECT VENT)
Combustion Air Opening Area (CAOA): Total Btu/hr divided
by 3000 Btu/hr per in2 CAOA = 75,000 / 3000 Btu/hr per inz = 25 in'
Step 8: Calculate Minimum CAOA.
Minimum CAOA = CAOA multiplied by RF Minimum CAOA = 25 x .49 = 12.25
in'
Step 9: Calculate Combustion Air Opening Diameter (CAOD)
CAOD = 1.13 multiplied by the square root of Minimum CAOA CAOD = 1.13 J Minimum CAOA = 3.96
in
1 If desired, ACH can be determined using ASHRAE calculation or blower door test. Follow procedures in Section
G304.
Although this worksheet, IFGC Appendix E, Worksheet E-1 and the following worksheet, IFGC Appendix E, Table
E-1, is referenced in the 2015 Minnesota Fuel Gas Code, these worksheets were not included in the published
copy.
4" Hard Pipe
5" Flex Pipe
5
Aspen Plan
HVAC Load Calculations
for
Thorson Homes
ipAsevart
,HVACRESIDENTIAL,
HVAC LOADS
Prepared By:
Josh Schindele
Flare Heating & Air Conditioning
9303 Plymouth Ave N
Golden Valley, MN 55427
763-542-1166
Tuesday, October 13, 2020
Rhvac is an ACCA approved Manual J, D and S computer program.
Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D.
Rhvac - Resi
ht Inc. I
Flare Heating& A/C Inc.
Golden Valle d MNIa9 55427-3700 ommercial HVAC Loads Elite SoftwarebeveloAspen1Pl n ,
YPa e2I
Project Report
General Project Information
Project Title: Aspen Plan
Designed By: Josh
Project Date: Tuesday, October 13, 2020
Client Name: Thorson Homes
Company Name: Flare Heating & Air Conditioning
Company Representative: Josh Schindele
Company Address: 9303 Plymouth Ave N
Company City: Golden Valley, MN 55427
Company Phone: 763-542-1166
Company Fax: 763-542-3101
Company E-Mail Address: jschindele@flareheating.com
Company Website: www.flareheating.com
Design Data
Reference City: Minneapolis/St. Paul AP, Minnesota
Building Orientation: Front door faces East
Daily Temperature Range: Medium
Latitude: 44 Degrees
Elevation: 834 ft.
Altitude Factor: 0.970
Outdoor Outdoor Outdoor Indoor Indoor Grains
Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference
Winter: -16 -16.32 n/a n/a 72 n/a
Summer: 93 71 34% 50% 72 22
Check Figures
Total Building Supply CFM: 1,242 CFM Per Square ft.: 0.320
Square ft. of Room Area: 3,882 Square ft. Per Ton: 1,452
Volume (ft3): 30,293
Building Loads
Total Heating Required Including Ventilation Air: 60,527 Btuh 60.527 MBH
Total Sensible Gain: 26,871 Btuh 84
Total Latent Gain: 5,205 Btuh 16 3/0
Total Cooling Required Including Ventilation Air: 32,075 Btuh 2.67 Tons (Based On Sensible + Latent)
1 Notes
Rhvac is an ACCA approved Manual J, D and S computer program.
Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at
your design conditions.
S:\FHDATA\PROJECTS\JOSH\Version6\Thorson Homes, Aspen Plan.rh9
Tuesday, October 13, 2020, 6:53 AM
Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc.
Flare Heating & A/C Inc. Aspen Plan
Golden Valley, MN 55427-3700 Page 3
Total Building Summary Loads f
Component Area Sen Lat Sen Total
Description Quan Loss Gain Gain Gain
2A-v-o: Glazing -Double pane low-e (e = 0.60), operable 441 11,254 0 9,793 9,793
window, vinyl frame, outdoor insect screen with 50%
coverage, U-value 0.29, SHGC 0.22
11N: Door -Metal - Polystyrene Core, U-value 0.35 38 1,170 0 426 426
12F-0sw: Wall -Frame, R-21 insulation in 2 x 6 stud 2863 16,376 0 3,965 3,965
cavity, no board insulation, siding finish, wood studs,
U-value 0.065
15B0-10sf-4: Wall -Basement, , R-10 board insulation to 330 2,006 0 248 248
floor, no interior finish, 4' floor depth, U-value 0.054,
above grade U-value 0.083
15B0-10sf-8: Wall -Basement, , R-10 board insulation to 648 3,059 0 104 104
floor, no interior finish, 8' floor depth, U-value 0.05,
above grade U-value 0.083
12D1-0sw: Wall -Frame, R-21 closed cell 2 lb. spray foam 160 1,070 0 310 310
insulation in 2 x 4 stud cavity, no board insulation,
siding finish, wood studs, U-value 0.076
168-50: Roof/Ceiling-Under Attic with Insulation on Attic 1322 2,327 0 1,481 1,481
Floor (also use for Knee Walls and Partition
Ceilings), Vented Attic, No Radiant Barrier, Dark
Asphalt Shingles or Dark Metal, Tar and Gravel or
Membrane, R-50 insulation, U-value 0.02
21A-20: Floor -Basement, Concrete slab, any thickness, 2 1280 3,041 0 0 0
or more feet below grade, no insulation below floor,
any floor cover, shortest side of floor slab is 20' wide,
U-value 0.027
20P-30: Floor -Over open crawl space or garage, Passive, 42 129 0 24 24
R-30 blanket insulation, any cover, U-value 0.035
Subtotals for structure: 40,432 0 16,351 16,351
People: 5 1,000 1,150 2,150
Equipment: 683 3,430 4,113
Lighting: 0 0 0
Ductwork: 0 0 0 0
Infiltration: Winter CFM: 198, Summer CFM: 166 18,557 2,394 3,711 6,105
Ventilation: Winter CFM: 78, Summer CFM: 78 1,538 1,128 367 1,495
Exhaust: Winter CFM: 230, Summer CFM: 230
AED Excursion: 0 0 1,861 1,861
Total Building Load Totals: 60,527 5,205 26,871 32,075
Check Figures 1
Total Building Supply CFM: 1,242 CFM Per Square ft.: 0.320
Square ft. of Room Area: 3,882 Square ft. Per Ton: 1,452
Volume (ft3): 30,293
wBuld►ng Loads.:.,
Total Heating Required Including Ventilation Air: 60,527 Btuh 60.527 MBH
Total Sensible Gain: 26,871 Btuh 84 %
Total Latent Gain: 5,205 Btuh 16 %
Total Cooling Required Including Ventilation Air: 32,075 Btuh 2.67 Tons (Based On Sensible + Latent)
Notes
Rhvac is an ACCA approved Manual J, D and S computer program.
Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at
your design conditions.
S:\FHDATA\PROJECTS\JOSH\Version6\Thorson Homes, Aspen Plan.rh9
Tuesday, October 13, 2020, 6:53 AM
Rhvac - Residential & Light Commercial HVAC Loads
Flare Heating & A/C Inc.
Golden Valley, MN 55427-3700
Building Pie Chart
Building
Loss
60,527
Btuh
Building
Gain
32,075
Btuh
Wall 37%_-
Elite Software Development, Inc.
Aspen Plan
Page 4
Floor 5% Ventilation 3%
Roof 4%
Wall 14%
Glass 31%
Floor 0%
Roof 5%
Infiltration 31%
Door 2%
Glass 19%
AED Excursion 6%
Ventilation 5%
People 7%
Door 1
_Infiltration 19%
Equipment 13%
S:\FHDATA\PROJECTS\JOSH\Version6\Thorson Homes, Aspen Plan.rh9 Tuesday, October 13, 2020, 6:53 AM
City Inspection Dept. Copy
City Forester Copy
Applicant/Builder Copy
/loS-376
EAGAN
INDIVIDUAL RESIDENTIAL LOT
TREE PRESERVATION PLAN SUMMARY
CITY OF EAGAN FORESTRY DIVISION
651-675-5300
(BUILDER, PLEASE READ ATTACHMENTS)
Development Schramm Meadows
Lot Number
Address
Builder
6
697 Marie Ct
Block Number 1
Thorson Homes Inc
Phone Number: (612) 810-3597
Contact: Brian Thorson
Tree Protection Requirements:
Replacement Trees:
Tree Protection Fencing Installed on Site
Oak Tree Pruning (Immediately seal wounds during April 1 to July 31)
Therapeutic Pruning Required
Retaining Wall To Be Installed
Other:
X Not Required: No Mitigation is Required for this Application
Attachments:
Additional Notes:
As Follows:
Yes
No
(Refer to attached docrtrr ntgfjgt f�taORESTRY DIVISION
R'VIEWED
DATE (0-23 - 20zo
HE-000.0
ADDRESS:
0.4\ `1' —" —
N --��,
-xV" � � —r � � � , xxu.
6 D -.9 9 938— \ \ \
3 4 x 939.6
RIVE
0
•
x941.2 x9413
DENOTES SET IRON PIPE MONUMENT
DENOTES FOUND IRON PIPE MONUMENT
DENOTES PROPOSED DRAINAGE DIRECTION
• DENOTES SERVICE LOCATION
O DENOTES WOOD HUB
000.0 DENOTES EXISTING ELEVATION
® DENOTES PROPOSED ELEVATION
DENOTES HUB ELEVATION
Bohlen
Surveying & Associates
31432 Foliage Avenue
Northfield, MN 55057
Phone: (507) 645.7768
,meara bohlensurveyin9.com
1662 Cliff Road E
Burnsville, MN 55337
A Phone: (952) 895-9212
Fax: (952) 895-9259
9444
7.R941.J\ \
x940.3�1.
—93
--5
ti4
x9466 L
CERTIFICATE OF SURVEY
FOR
THORSON HOMES
1"=20'
LOT AREA = 13,080 SF
HOUSE AREA = 1,911 SF
NOTE.• ALL BUILDING
DIMENSIONS ARE SHOWN TO
OUTS/DE OF FOUNL477ON
WALL
DENOTES EXISTING CONTOUR
DENOTES PROPOSED CONTOUR
DENOTES BITUMINOUS SURFACE
DENOTES CONCRETE SURFACE
PROPOSED TOP OF WALL ELEV. = 948.2
PROPOSED GARAGE FLOOR ELEV. = 947.4
PROPOSED BASEMENT FLOOR ELEV. = 939.5
PROPERTY DESCRIPTION
LOT 6, BLOCK7 SCHRAMMMEADOW9 CITYOF
EAGAN, DAKOTA COUNTY, MINNESOTA.
I HEREBY CERTIFY THAT THIS SURVEY WAS PREPARED BY ME OR
UNDER MY DIRECT SUPERVISION AND THAT I AM A DULY LICENSED
LAND SURVEYOR UNDER THE LAWS OF THE STATE OF MINNESOTA.
DATE: 10-5-20
S.\Prniects\Fnnnn\soh rnmm mendnwa\dwn\'nth hlk1-7frt (-Iwo 10/5/2020 10- c1•00 AM CDT
THOMAS J. O'MEARA, LAND SURVEYOR
MINNESOTA LICENSE NO. 46167
697 Marie Ct
Aerial Street Names
en
m
f6
J
Storm Basin
en
D
c9
Sections Numbers
TREE PRESERVATION PLAN REVIEW - INDIVIDUAL LOT
EAGAN
Date Building Permit Application Received 10/22/2020
Development Schramm Meadows
Site Address 697 Marie Court
Lot 6
Block 1
Builder Thorson Homes
Contact Brian Thorson
Telephone (612) -810-3597 E-mail brian@thorsonhomes.com
Property/Lot Owner Name -
Telephone -
E-mail -
Office Plan Review — Date 110/23/2020 Notes No Mitigation is required for this application
Tree planting is encouraged and plantings must remain outside righ-of-way setback.
Tree protection must remain in place until construction completion.
Tree Preservation Data Original Plan Revised Plan
Total Significant Woodland Area sq. ft sq. ft
Total Significant Trees
Woodland To Be Removed sq. ft sq. ft
Trees To Be Removed
Allowable Woodland Removal (20%) sq. ft sq. ft
Allowable Tree Removal (20%)
Required Mitigation YES (or) NO
Calculated Mitigation Amounts
Original Plan - Category A Category B Category C
Revised Plan - Category A Category B Category C
Site Inspection — Date 12/23/2020
Notes Site grading complete and House location staked
Pe pre -i - -e4 -f-re •S p - = I o 441'L f - -s t p -o %c c -t —..
►. -41 :3,4..-eit .
G:\Forestry\TreePreservation\Tree Preservation Plan Review - Individual Lot.docx
Original Tree Preservation Plan Approved — Date 5/18/20
Forwarded to Inspections — Date 10/23/2020
By
By
Discussion/Meetings with Builder/Owner - Notes
Revised Tree Preservation Plan Approved — Date By
Forwarded to Inspections — Date By
Additional Field Inspections
Date Notes
Date Notes
Date Notes
Date Notes
G:\Forestry\TreePreservation\Tree Preservation Plan Review - Individual Lot.docx
Was the approved Tree Preservation Plan followed? YES (or) NO
If no, was additional mitigation required? YES (or) NO (If yes, describe additional mitigation below)
Final Site Inspection — Date Notes
Additional Notes and/or aerial photo image
(insert aerial image or draw map of site)
G:\Forestry\TreePreservation\Tree Preservation Plan Review - Individual Lot.docx
O z
O ❑
O ❑
O ❑
O ❑
0 ❑
O ❑
O ❑
O ❑
O ❑
O ❑
O ❑
O ❑
❑❑❑❑❑❑❑❑❑❑❑❑ Add/Change
PROPERTY LEGAL:
LOT SURVEY CHECKLIST FOR RESIDENTIAL
BUILDING PERMIT APPLICATION
Lot 6, Block 1, Schramm Meadows
DATE OF SURVEY: 10/5/2020
LATEST REVISION:
DOCUMENT STANDARDS
• Registered Land Surveyor signature and company
• Building Permit Applicant
• Legal description
• Address
• North arrow and scale
• House type (rambler, walkout, split w/o, split entry, lookout, etc.)
• Directional drainage arrows with slope/gradient %
• Proposed/existing sewer and water services & invert elevation
• Street name
• Driveway (grade & width - in RNV and back of curb, 22' max.)
• Lot Square Footage
• Lot Coverage
ELEVATIONS
Existing
0 0 0 • Property corners
O 0 0 • Top of curb at the driveway and property line extensions
❑ 0 0 • Elevations of any existing adjacent homes
❑❑ 0 ❑❑ • Adequate footing depth of structures due to adjacent utility trenches
• Waterways (pond, stream, etc.)
❑ ❑ ❑
O ❑ ❑
O ❑ ❑
O ❑ ❑
O ❑ ❑
Yes
❑ 0 ❑
❑ 0❑
❑ 0❑
❑ 0 ❑
❑ 0❑
❑ 0❑
No
I —
O ❑ ❑
O ❑❑
O ❑❑
O ❑❑
O ❑❑
O ❑❑
Proposed
• Garage floor
• Basement floor
• Lowest exposed elevation (walkout/window)
• Property corners
• Front and rear of home at the foundation
• PRV Required
PONDING AREA (if applicable)
• Easement line
• NWL
• HWL
• Pond # designation
• Emergency Overflow Elevation
• Pond/Wetland buffer delineation
• Shoreland Zoning Overlay District
• Conservation Easements
DIMENSIONS
• Lot lines/Bearings & dimensions
• Right-of-way and street width (to back of curb)
• Proposed home dimensions including any proposed decks, overhangs greater than 2', porches, etc.
(i.e. all structures requiring permanent footings)
• Show all easements of record and any City utilities within those easements
• Setbacks of proposed structure and sideyard setback of adjacent existing structures
• Retaining wall requirements:
Reviewed By: Dave Westermayer
Date 10/26/2020
G:/1 Engineering/Forms/Cert. of Survey Checklist Fillable 6-28-19
.- A
/05. y L/-)
8
ADDRESS: 447 Mole- at.
0.4 R R Ffp,
INF* - 4 rUNAT 44.•
Tx --
941.2
T8.5X 938.0
x 937:9
•
x 939.6
RIVE
7
144.2
- -
941.6
5 \
'Z.
3:1 Maximum Slopes
or i7 !aning Wall Will
Be 1,;iequired _44
x
-1/4.9446,
x 941.2
x 937 9
co
CY)
946.2
144.6
938
N78. IL., \
41.6
eAszi7e447(_____
Se7Z?4Cir Z/Ne
x94/.2
x941.3
LOT 6
x"zBLOCK 1
X 9382
x 9.39.2
Ito
ol o'71:9f?c,y
19,5
41.
CERTIFICATE OF SURVEY
FOR
THORSON HOMES
N ISTALL
PERIMETER CONTROL
tr)
x 941.2
x 940.1
x 93Z2
X 938.3
12.8
x 939.7
Dear
/7.3 te)
ezzo
PROPOSED
HOUSE
FB/WO x 939*°
x 943.9
ci 8.5
943.
946.6x
CURB
STOP 945.4
- x
s,,945.0
! 945.0
CONCRETE CURB & GU1TER
GARAGE
1.98
x 939.4
x 941.3
OZs
5
1
x 93 .9 1
c27,
13)
.0
CC)
11,
94.3.7
943.8 X
22
944.0x
11. o
c‘i
PROPOSED
DRIVEWAY
5.3%
0
945..3
oll4r4
x 940.3
10
x941.
..cr)
CO azz
944.1c
44.4
945.4
946. t
945.7
x 946.6
462
e5.7
70.27
MARIE COURT
58725 '28 nE
CENTER UNE
0 DENOTES SET IRON PIPE MONUMENT
• DENOTES FOUND IRON PIPE MONUMENT
DENOTES PROPOSED DRAINAGE DIRECTION ---(000)
000.0
E = 000.0
DENOTES SERVICE LOCATION
DENOTES WOOD HUB
DENOTES EXISTING ELEVATION
DENOTES PROPOSED ELEVATION
DENOTES HUB ELEVATION
Bohlen
Surveying & Associates By
31432 Foliage Avenue
Northfield, MN 55057
Phone: (507)645-7768
meara@bohlensurveying.com
3
A
1682 Cliff Road E. Date
Burnsville, MN 55337
Phone: (952) 895-9212
Fax: (952) 895-9259
IENNED
EAGAN ENGINEERING DEPT,
x 93
X 3.
1" = 20'
LOT AREA = 13,080 SF
HOUSE AREA = 1,911 SF
NOTE: ALL BUILDING
DIMENSIONS ARE SHOWN TO
OUTS/DE OF FOUNDATION
WALL
DENOTES EXISTING CONTOUR
DENOTES PROPOSED CONTOUR
DENOTES BITUMINOUS SURFACE
DENOTES CONCRETE SURFACE
PROPOSED TOP OF WALL ELEV. = 948.2
PROPOSED GARAGE FLOOR ELEV. = 947.4
PROPOSED BASEMENT FLOOR ELEV. = 939.5
PROPERTY DESCRIPTION
LOT 6; BLOCK 1, SCHRAMM MEADOWS, CITY OF
EAGAN, DAKOTA COUNTY, MINNESOTA.
I HEREBY CERTIFY THAT THIS SURVEY WAS PREPARED BY ME OR
UNDER MY DIRECT SUPERVISION AND THAT I AM A DULY LICENSED
LAND SURVEYOR UNDER THE LAWS OF THE STATE OF MINNESOTA.
DATE: 10-5-20
Thy (3Pluvta,
c•\ Prniporfq\ Faaan\
THOMAS J. O'MEARA, LAND SURVEYOR
MINNESOTA LICENSE NO. 46167
schramm meadows\ dwa \ lot6bIk1 cerLdwa 10/5/2020 10:59:00 AtimirpT
PERMIT
City of Eagan Permit Type:Plumbing
Permit Number:EA169054
Date Issued:05/13/2021
Permit Category:ePermit
Site Address: 697 Marie Ct
Lot:6 Block: 1 Addition: Schramm Meadows
PID:10-67620-01-060
Use:
Description:
Sub Type:Residential
Work Type:Replace
Description:Water Softener
Meter Size Meter Type Manufacturer Serial Number Remote Number Line Size
Comments:Carbon monoxide detectors are required within 10 feet of all sleeping room openings in residential homes (Minnesota State
Building Code).
Please call Building Inspections at (651) 675-5675 to schedule a final inspection.
Fee Summary:PL - Permit Fee (WS &/or WH)$59.00 0801.4087
Surcharge-Fixed $1.00 9001.2195
$60.00 Total:
I hereby acknowledge that I have read this application and state that the information is correct and agree to comply with all applicable State
of Minnesota Statutes and City of Eagan Ordinances.
Contractor:Owner:- Applicant -
Daniel C & Megan J Bissell
697 Marie Ct
Eagan MN 55123
(763) 234-0606
Milbert Company (culligan)
1801 50th St E
Inver Grove Heights MN 55077
(651) 451-2241
Applicant/Permitee: Signature Issued By: Signature