2021 RESIDENTIAL BUILDING PERMIT APPLICATION
&' o ill y
Date:
For Office Use
i
i
Permit#:
Permit Fee: /o
Site Address:
Date Received: / //'
Staff:
Unit #:
Res a t!
Qyy er
Name: l t^ o ff.. OdvA►es Trrc Phone: 4(i- fSe_ o W
Address / City / Zip: 4 K 6 b (,J e 4e -•41 ant y t 4*. /V14,►- SSI Z3
Applicant is: Id Owner 'r Contractor /,7/ 3 I/o GK / SC//,/2aw L
Type of Work '
Description of work: t4 ew Colt-,VAi1f(j , ! I
Construction Cost: Multi -Family Building: (Yes / No )
COnt AC
Company: l Nves/h 41•''r►L) Z7e Contact: 11�4."
t
qq‘i
Address: Weivit i+i rtiY./ City: tatty)
State: MU Zip: Silo Phone:6141°'35 !7 Email: 17e10►00416441).4
License #: I 3 17 Lead Certificate #:
If the project is exempt
from lead certification, please explain why:
In the last 12 months,
Yes ' No
COMPLETE THIS AREA ONLY IF CONSTRUCTING A NEW BUILDING
has the City of Eagan issued a permit for a similar plan based on a master plan?
If yes, date and address of master plan:
Licensed Plumber:
Mechanical Contractor:
Sewer & Water Contractor:
Fire Suppression Contractor:
57lIV[— tme' `l 11 Phone: Eft - Q t$ - 2'117
I' 7
��eY grtn•�j Phone: 76 > • scli- I1 It t
0 plolvt,aceCO1 vbeiti Phone: 6L2-3 is9 - ger?
Phone:
NOTE: Plans and supporting documents that you submit are considered to be public information Portions of the Information,may be
classified as non-public if you provide specific reasons that would permit the City to conclude that they are trade secrets..
You may subscribe to receive an electronic notification from the City of proposed ordinances by signing up for an email update on the City's
website at www.citvofeaoan.com/subscribe.
Exterior work authorized by a building permit issued in accordance with the Minnesota State Building Code must be completed within 180
days of permit issuance.
CALL BEFORE YOU DIG. Call Gopher State One Call at (651) 454-0002 for protection against underground utility damage. Call 48 hours before you
intend to dig to receive locates of underground utilities. www.gopherstateonecall.orq
I hereby acknowledge that this information is complete and accurate; that the work will be in conformance with the ordinances and codes of the City
Eagan; that I understand this is not a permit, but only an application for a permit, and work is not to start without a permit; that the work will
accordance with the approved plan in the case of work which requires a review and approval of plans.
X LZ , k
Applicant's Printed Name
Applicant's Signature
SUB TYPES
Foundation
ASingle Family
Multi
01 of _ Plex
WORK TYPES
Ni New
✓✓' Addition
Alteration
Replace
DESCRIPTION
Calculated Valuation
Plan Review
(25%_ 100°0
Census de
# of Units
# of Buildings
Type of Construction
FOR OFF
CE USE ONLY
Site Address: (QQ0 / l 6iz i E �r
Fireplace
Garage
Deck
Lower Level
Repair
Fire Repair
Water Damage
Egress Window
REQUIRED INSPECTIONS
/5
Footings (New Building)
Footings (Deck)
Footings (Addition)
Foundation Foundation Before Backfill
Roof: Ice Slater _Final
Framing 30 Minutes N,4, 1 Hour
Fireplace: y Rough In `/ir Test Final
Insulation !`
Sheathing
Sheetrock
Fire Walls
y\ Braced Walls
Shower Pan
Reviewed By:
RESIDENTIAL FEES
Calculated Valuation
Base Fee
Plan Review
State Surcharge
MCES SAC
City SAC
Utility Connection Charge
S&W Permit & Surcharge
Treatment Plant
Radio Read
Other:
opies:
Porch (3-Season)
Porch (4-Season)
Porch (Screen/Gazebo/Pergola)
Pool
— Siding
Reroof
Windows
— Solar
Occupancy
Code Edition
Zoning
Stories
Square Feet
Length
Width
Permit #:
Miscellaneous
Accessory Building
Retaining Wall
Move Building
Demolish Building*
*Demolition of entire building — give PCA handout to
applicant
MCES System
SAC Units
City Water
Booster Pump
PRV
Fire Suppression Required
Meter Size:
Final / C.O. Required
Final / No C.O. Required
HVAC _ Service Test Gas Line Air Test _ Hood
Pool: _Footings _Air/Gas Tests _Final
Drain Tile
Siding: _Stucco Lath Lath�Brick _ EFIS
Windows
Retaining Wall: _ Footings _ Backfill _ Final
Radon Control
Fire Suppression: _Rough In _Final
Erosion Control
Other:
, Building Inspector
Fes' ) /2S93,d,h!
61filfi lipl-Ps)`55)? V I (4 cic
iifr-' 1970 k 9r,73'
(ytoT31l9t' r.q 3 X � �, t� (g Sb
6-Ptj )77V/151
106/te-- /5".7 L-115/A9
Sri, �I �2 �►�
TOTAL $ 0.00
New Construction Energy Code Compliance Certificate
Per R401.3 Certificate. A building certificate shall be posted on or in the electrical distribution
panel.
Date Certificate Posted
Address of the Dwelling or Dwelling Unit
690 Marie Ct
City�7
.al
arTf7Mailing
[�
'L�
Eagan
Name of Residential Contractor
Thorson Homes
MN License Number
1317
HEATING A AIR CONDITONING
THERMAL ENVELOPE
RADON CONTROL,SYSTEM
Total R-Value of all Types of
Insulation
Type: Check All That Apply
X
Passive (No Fan)
c
a)
Active (With fan and mono meter or other
system monitoring device)
m
N
Location (or future location) of Fan:
Non or Not Applicat
Fiberglass, Blown
Fiberglass, Batts
Foam, Closed Cell
Foam Open Cell
Mineral Fiberboard
Rigid, Extruded Poly
Rigid, isocynurate
Insulation Location
Other Please Describe Here
Below Entire Slab
Foundation Wall
1O
x
Perimeter of Slab on Grade
Rim Joist (1st Floor)
TO f)
x
Rim Joist (2nd Floor+)
1004
X
Wall
to
Ceiling, flat
49
X
Ceiling, vaulted
1
qCI
X
Bay Windows or cantilevered areas
x
Floors over unconditioned area
Describe other insulated areas
Building envelope air tightness:
Duct system air tightness:
Windows & Doors
Heating or Cooling Ducts Outside Conditioned Spaces
Average U-Factor (excludes skylights and one door) U:
L.
21
X
Not applicable, all ducts located in conditioned space
Solar Heat Gain Coefficient (SHGC):
R-value
MECHANICAL SYSTEMS
Make up Air Select a Type
Appliances
HeatingSystem
y
Domestic Water
Heater
Cooling System
X
Not required per mech. code
Fuel Type
NATURAL GAS
PA Cy ,
R410A
Passive
Manufacturer
Carrier
ACQ riki4
Carrier
Powered
Model
59SC5B080
CA13NA030
Interlocked with exhaust device.
Describe:
Rating or Size
Input in
STUS:
80,000
Capacity
in Gallons:
7�
Output
n Tons:
2.5
Other, describe:
Efficiency
AFUE or
HSPF%
95%
SEER
/EER
13
Location
of duct or system:
Residential Load Calculate
Heating Loss
Heating Gain
Cooling Load
54,028
28,818
2.4
Cfm's
" round duct OR
MECHANICAL VENTILATION SYSTEM
" metal duct
Describe any additional or combined heating or cooling systems if installed: (e.g. two furnaces or air
Combustion
Air Select a Type
source heat pump with gas back-up furnace):
Not required per mech. code
Select Type
X
Passive
Heat Recover Ventilator (HRV) Capacity in cfms:
Low:
High:
Other, describe:
X
Energy Recover Ventilator (ERV) Capacity in cfms:
Low:
78
High:
155
Location of duct or system:
Balanced Ventilation capacity in cfms:
MECHANICAL ROOM
Location of fan(s), describe:
Cfm's
Capacity continuous ventilation rate in cfms:
7
" round duct OR
Total ventilation (intermittent + continuous) rate in cfms:
6
" metal duct
Builders Associaton of Minnesota version 101014
Thorson Homes, 690 Marie Ct, Eagan
2015 Mechanical & Energy Code — Ventilation, Makeup, and Combustion Air
Calculations
Ventilation Quantity
(Determine quantity by using Table R403.5.2 or Equation R403.5..2, 2015 Minnesota Energy Code)
Square feet (Conditioned area including
Basement — finished or unfinished)
Number of bedrooms
3775
4
Total required ventilation
Continuous ventilation
155
78
Directions - Determine the total and continuous ventilation rate by either using Table N1104.2 or equation 11-1.
Insert the square footage, total required ventilation and continuous ventilation in the Mechanical Submittal form.
The table and equation are below.
Table R403.5.2 2015 Minnesota Energy Code
Total and Continuous Ventilation Rates (in cfm)
N
Number of Bedrooms
1
2
3
4
5
6
Conditioned space (in
sq. ft.)
Total/
continuous
Total/
continuous
Total/
continuous
Total/
continuous
Total/
continuous
Total/
continuous
1000-1500
60/40
75/40
90/45
105/53
120/60
135/68
1501-2000
70/40
85/43
100/50
115/58
130/65
145/73
2001-2500
80/40
95/48
110/55
125/63
140/70
155/78
2501-3000
90/45
105/53
120/60
135/68
150/75
165/83
3001-3500
100/50
115/58
130/65
145/73
160/80
175/88
3501-4000
110/55
125/63
140/70
155/78
170/85
185/93
4001-4500
120/60
135/68
150/75
165/83
180/90
195/98
4501-5000
130/65
145/73
160/80
175/88
190/95
205/103
5001-5500
140/70
155/78
170/85
185/93
200/100
215/108
5501-6000
150/75
165/;83
180/90
195/98
210/105
225/113
Enuatinn RAM g 9 9Mg nn: a .,_ .
(0.02 x square feet of conditioned space) + [15 x (number of bedrooms + 1)] = Total ventilation rate (cfm)
Example: (0.02 x 3000) +[15 x (3 + 1)] = Total ventilation rate = 120 cfm
Total ventilation — The mechanical ventilation system shall provide sufficient outdoor air to equal the total
ventilation rate average for each one -hour period according to the above table or equation. For heat recovery
ventilators (HRV) and energy recovery ventilators (ERV) the average hourly ventilation capacity must be
determined in consideration of any reduction of exhaust or outdoor air intake, or both, for defrost or other
equipment cycling.
Continuous ventilation - A minimum of 50 percent of the total ventilation rate, but not less than 40 cfm, shall be
provided, on a continuous rate average for each one -hour period. The portion of the mechanical ventilation
system intended to be continuously may have automatic cycling controls providing the average flow rate for each
hour is met.
1
Thorson Homes, 690 Marie Ct, Eagan
Directions - In order to determine the makeup air for ventilation, Table 501.4.1 must be filled out (see below). For
most new installations, column A will be appropriate, however, if kitchen hoods exceed 300 cfm, atmospherically
vented appliances or solid fuel appliances are installed, use the appropriate column. Please note, if the makeup
air quantity is negative, no additional makeup air will be required for ventilation, if the value is positive refer to
Table 501.4.2 and size the opening. Transfer the cfm, size of opening and type (round, rectangular, flex or rigid)
to the last line of section D. The ventilation make-up air supply must communicate with the exhaust appliances.
Table 501.4.1, 2015 Minnesota Mechanical Code
PROCEDURE TO DETERM NE MAKEUP AIR QUANITY FOR EXHAUST APPLIANCES IN DWELLING UNITS
(Additional makeup air will be required for combustion appliances,
One or multiple power
vent or direct vent
appliances or no
combustion appliances
Column A
see
One or multiple fan-
assisted appliances
and power vent or
direct vent appliances
Column B
KAIR method for calculations)
One atmospherically
vented gas or oil
appliance or one solid
fuel appliance
Column C
Multiple
atmospherically
vented gas or oil
appliances or solid
fuel appliances
Column D
1.Enter the Appropriate Column to Estimate House Infiltration
a) pressure factor
(cfm/sf)
0.15
0.09
0.06
0.03
b) conditioned floor area (sf)
(including unfinished basements)
Estimated
3775
House Infiltration (cfm):
Ma x 1bJ
566
2. Exhaust Capacity
a) clothes dryer (cfm)
135
135
135
135
b) 80% of largest exhaust rating
(cfm); 300
(not applicable if recirculating
system or if powered makeup air is
electrically interlocked and match to
exhaust)
240
c) 80% of next largest exhaust
rating (cfm); 80
(not applicable if recirculating
system or if powered makeup air is
electrically interlocked and matched
to exhaust)
Total
64
Exhaust Capacity (cfm);
[2a + 2b +2c]
439
3. Makeup Air Quantity (cfm)
a) total exhaust capacity (from
above)
b)
439
estimated house infiltration (from
above)
566
Makeup Air Quantity (cfm);
[3a — 3b]
(if value is negative, no makeup air
is needed)
4.
-127
For makeup Air Opening Sizing,
refer to Table 501.4.2
NSA
A.
Use this column if there are other than
appliances. (Power vent and direct ves
B. Use this column if there is one fan-assi
may also be included.)
C. Use this column if there is one atmospf
fuel appliance.
D. Use this column if there are multiple atr
atmospherically vented gas or oil appli�
fan -assisted or atmospherically vented gas or oil appliance or if there are no combustion
y be used.)
>ted appliance per venting system. (Appliances other than atmospherically vented appliances
erically vented (other than fan -assisted) gas or oil appliance per venting system or one solid
iospherically vented gas or oil appliances using a common vent or if there are
nces and solid fuel appliances.
t aooli
Be advised: 2015 Minnesota Mechanical Code, Section 505.2, Installation of exhaust hood systems capable of
exhausting in excess of 400 cfm shall be provide with makeup air at a rate approximately equal to the exhaust air
rate. Such makeup air systems shall be equipped with a means of closure and shall be automatically controlled
to start and operate simultaneously with the exhaust system.
3
Thorson Homes, 690 Marie Ct, Eagan
IFGC Appendix E, Worksheet E-1
Residential Combustion Air Calculation Method
(for Furnace, Boiler, and/or Water Heater in the Same Space)
Step 1: Complete vented combustion appliance information.
Furnace/Boiler:
_ Draft Hood Fan Assisted X Direct Vent Input: 80,000 Btu/hr
(not fan -assisted & Power Vent
Water Heater:
_ Draft Hood _X Fan Assisted Direct Vent Input: 75,000 Btu/hr
(not fan -assisted) & Power Vent
Step 2: Calculate the volume of the Combustion Appliance Space (CAS) containing combustion appliances.
The CAS includes all spaces connected to one another by code compliant openings. CAS volume: 693
ft3
Step 3: Determine Air Changes per Hour (ACH)1
Default ACH values have been incorporated into Table E-1 for use with Method 4b (KAIR Method). If the year
of construction or ACH is not known, use method 4a (Standard Method).
Step 4: Determine Required Volume for Combustion Air.
4a. Standard Method
Total Btu/hr input of all combustion appliances (DO NOT COUNT Input: 75,000 Btu/hr
DIRECT VENT APPLIANCES)
Use Standard Method column in Table E-1 to find Total Required TRV: 3750 ft3
Volume (TRV)
If CAS Volume (from Step 2) is greater than TRV then no outdoor openings are needed.
If CAS Volume (from Step 2) is less than TRV then go to STEP 5.
4b. Known Air Infiltration Rate (KAIR) Method
Total Btu/hr input of all fan -assisted and power vent appliances Input: Btu/hr
(DO NOT COUNT DIRECT VENT APPLIANCES)
Use Fan -Assisted Appliances column in Table E-1 to find RVFA: ft3
Required Volume Fan Assisted (RVFA)
Total Btu/hr input of all non -fan -assisted appliances Input: Btu/hr
Use Non -Fan -Assisted Appliances column in Table E-1 to find RVNFA: ft3
Required Volume Non -Fan -Assisted (RVNFA)
Total Required Volume (TRV) = RVFA + RVNFA TRV = + = ft3
If CAS Volume (from Step 2) is greater than TRV then no outdoor openings are needed.
If CAS Volume (from Step 2) is less than TRV then go to STEP 5.
Step 5: Calculate the ratio of available interior volume to the total required volume. Ratio = CAS Volume (from
Step 2) divided by TRV (from Step 4a or Step 4b)
Ratio = 693 / 3750 = .18
Step 6: Calculate Reduction Factor (RF).
RF = 1 minus Ratio Ratio RF = 1 - .18 = .82
Step 7: Calculate single outdoor opening as if all combustion air is from outside.
Total Btu/hr input of all Combustion Appliances in the same CAS Input: 75,000 Btu/hr
(EXCEPT DIRECT VENT)
Combustion Air Opening Area (CAOA): Total Btu/hr divided
by 3000 Btu/hr per in2 CAOA = 75,000 / 3000 Btu/hr per in2 = 25 in2
Step 8: Calculate Minimum CAOA.
Minimum CAOA = CAOA multiplied by RF Minimum CAOA = 25 x .82 = 20.5
in2
Step 9: Calculate Combustion Air Opening Diameter (CAOD)
CAOD = 1.13 multiplied by the square root of Minimum CAOA CAOD = 1.13 q Minimum CAOA = 5.16
in
1 If desired, ACH can be determined using ASHRAE calculation or blower door test. Follow procedures in Section
G304.
Although this worksheet, IFGC Appendix E, Worksheet E-1 and the following worksheet, IFGC Appendix E, Table
E-1, is referenced in the 2015 Minnesota Fuel Gas Code, these worksheets were not included in the published
copy.
6" Hard Pipe
7" Flex Pipe
5
Robertson Residence
HVAC Load Calculations
for
Thorson Homes
Prepared By:
Josh Schindele
Flare Heating & Air Conditioning
9303 Plymouth Ave N
Golden Valley, MN 55427
763-542-1166
Monday, January 4, 2021
Rhvac is an ACCA approved Manual J, D and S computer program.
Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D.
Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc.
Flare Heating & A/C Inc. Robertson Residence
Golden Valley, MN 55427-3700 Page 2
Project Report
General Project Information
Project Title: Robertson Residence
Designed By: Josh
Project Date: Monday, November 16, 2020
Client Name: Thorson Homes
Company Name: Flare Heating & Air Conditioning
Company Representative: Josh Schindele
Company Address: 9303 Plymouth Ave N
Company City: Golden Valley, MN 55427
Company Phone: 763-542-1166
Company Fax: 763-542-3101
Company E-Mail Address: jschindele@flareheating.com
Company Website: www.flareheating.com
Design Data
Reference City: Minneapolis/St. Paul AP, Minnesota
Building Orientation: Front door faces East
Daily Temperature Range: Medium
Latitude: 44 Degrees
Elevation: 834 ft.
Altitude Factor: 0.970
Outdoor Outdoor Outdoor Indoor Indoor Grains
Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference
Winter: -16 -16.32 n/a n/a 72 n/a
Summer: 93 71 34% 50% 72 22
Check Figures
Total Building Supply CFM: 1,120 CFM Per Square ft.: 0.297
Square ft. of Room Area: 3,775 Square ft. Per Ton: 1,572
Volume (ft3): 30,897
Building Loads
Total Heating Required Including Ventilation Air: 54,028 Btuh 54.028 MBH
Total Sensible Gain: 24,279 Btuh 84 %
Total Latent Gain: 4,539 Btuh 16 %
Total Cooling Required Including Ventilation Air: 28,818 Btuh 2.40 Tons (Based On Sensible + Latent)
Notes
Rhvac is an ACCA approved Manual J, D and S computer program.
Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at
your design conditions.
S:\FHDATA\PROJECTS\JOSH\Version6\Thorson Homes, 690 Marie Ct, Eagan.rh9
Monday, January 4, 2021, 6:55 AM
16B-50:
21A-20:
20P-30:
Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc.
Flare Heating & A/C Inc. Robertson Residence
Golden Valley, MN 55427-3700 Page 3,
Total Building Summary Loads
Component Area Sen Lat Sen Total
Description Quan Loss Gain Gain Gain
2A-v-o: Glazing -Double pane low-e (e = 0.60), operable 393 10,030 0 8,421 8,421
window, vinyl frame, outdoor insect screen with 50%
coverage, U-value 0.29, SHGC 0.22
11 N: Door -Metal - Polystyrene Core, U-value 0.35 38 1,170 0 426 426
15B0-10sf-4: Wall -Basement, , R-10 board insulation to 430 2,429 0 219 219
floor, no interior finish, 4' floor depth, U-value 0.054,
above grade U-value 0.083
12F-0sw: Wall -Frame, R-21 insulation in 2 x 6 stud 2534 14,494 0 3,507 3,507
cavity, no board insulation, siding finish, wood studs,
U-value 0.065
15B0-10sf-8: Wall -Basement, , R-10 board insulation to 675 3,185 0 107 107
floor, no interior finish, 8' floor depth, U-value 0.05,
above grade U-value 0.083
12F1-0sw: Wall -Frame, R-21 open cell 1/2 lb. spray foam 315 1,802 0 436 436
insulation in 2 x 6 stud cavity, no board insulation,
siding finish, wood studs, U-value 0.065
Roof/Ceiling-Under Attic with Insulation on Attic 1917 3,374 0 2,147 2,147
Floor (also use for Knee Walls and Partition
Ceilings), Vented Attic, No Radiant Barrier, Dark
Asphalt Shingles or Dark Metal, Tar and Gravel or
Membrane, R-50 insulation, U-value 0.02
Floor -Basement, Concrete slab, any thickness, 2 1858 4,415 0 0 0
or more feet below grade, no insulation below floor,
any floor cover, shortest side of floor slab is 20' wide,
U-value 0.027
Floor -Over open crawl space or garage, Passive, 59 182 0 33 33
R-30 blanket insulation, any cover, U-value 0.035
Subtotals for structure: 41,081 0 15,296 15,296
People: 5 1,000 1,150 2,150
Equipment: 1,131 4,262 5,393
Lighting: 0 0 0
Ductwork: 0 0 0 0
Infiltration: Winter CFM: 121, Summer CFM: 89 11,409 1,280 1,984 3,264
Ventilation: Winter CFM: 78, Summer CFM: 78 1,538 1,128 367 1,495
Exhaust: Winter CFM: 150, Summer CFM: 150
AED Excursion: 0 0 1,220 1,220
Total Building Load Totals: 54,028 4,539 24,279 28,818
Check Figures
Total Building Supply CFM: 1,120 CFM Per Square ft.: 0.297
Square ft. of Room Area: 3,775 Square ft. Per Ton: 1,572
Volume (ft3): 30,897
Building Loads
Total Heating Required Including Ventilation Air: 54,028 Btuh 54.028 MBH
Total Sensible Gain: 24,279 Btuh 84
Total Latent Gain: 4,539 Btuh 16 %
Total Cooling Required Including Ventilation Air: 28,818 Btuh 2.40 Tons (Based On Sensible + Latent)
Notes
Rhvac is an ACCA approved Manual J, D and S computer program.
Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at
your design conditions.
S:\FHDATA\PROJECTS\JOSH\Version6\Thorson Homes, 690 Marie Ct, Eagan.rh9
Monday, January 4, 2021, 6:55 AM
Rhvac - Residential & Light Commercial HVAC Loads
Flare Heating & A/C Inc.
Golden Valley, MN 55427-3700
s
Building Pie Chart
Building
Loss
54,028
Btuh
Building
Gain
28,818
Btuh
Floor 9%
Roof 6%\
Wall 41% Glass 19%
Ventilation 3%
Elite Software Development, Inc.
Robertson Residence
Page 4
iInfiltration 21
Door 2%
Wall 15%�
Glass 29%
Floor 0%
Roof 7%
ED Excursion 4%
Ventilation 5%
,Infiltration 11 %
People 7%
Door 1
Equipment 19%
S:\FHDATA\PROJECTS\JOSH\Version6\Thorson Homes, 690 Marie Ct, Eagan.rh9 Monday, January 4, 2021, 6:55 AM
City Inspection Dept. Copy
City Forester Copy
Applicant/Builder Copy
EAGAN
INDIVIDUAL RESIDENTIAL LOT
TREE PRESERVATION PLAN SUMMARY
CITY OF EAGAN FORESTRY DIVISION
651-675-5300
(BUILDER, PLEASE READ ATTACHMENTS)
Development Schramm Meadows
Lot Number
Address
Builder
3
690 Marie Ct
Block Number 1
Thorson Homes Inc
Phone Number: (612) 810-3597
Contact: Brian Thorson
Tree Protection Requirements:
Replacement Trees:
Tree Protection Fencing Installed on Site
Oak Tree Pruning (Immediately seal wounds during April 1 to July 31)
Therapeutic Pruning Required
Retaining Wall To Be Installed
Other:
X Not Required: No Mitigation is Required for this Application
Attachments:
As Follows:
X Yes (Refer to attache
No
Additional Notes:
d eAGAN'eFORESTRY DIVISION
REVIEWED
BY oittit. - OA*
DATE t -I -2o2,j
69 o Marie Ct
Aerial Street Names
Storm Basin
Sections Numbers
TREE PRESERVATION PLAN REVIEW — INDIVIDUAL LOT
EAGAN
Date Building Permit Application Received 1/12/2021
Development Schramm Meadows
Site Address 690 Marie Court
Builder Thorson Homes
Telephone (612) -810-3597
Property/Lot Owner Name -
Telephone -
Lot 3 Block 1
Contact Brian Thorson
E-mail brianathorsonhomes.corn
E-mail -
Office Plan Review — Date 1/12/2021 Notes No mitigation is required for this application
Tree planting is encouraged and plantings must remain outside right-of-way setback. Tree protection
must remain in place until construction completion.
Tree Preservation Data Original Plan
Revised Plan
Total Significant Woodland Area sq. ft
sq. ft
Total Significant Trees
Woodland To Be Removed
sq. ft sq. ft
Trees To Be Removed
Allowable Woodland Removal (20%)
sq. ft sq. ft
Allowable Tree Removal (20%)
Required Mitigation YES (or) NO
Calculated Mitigation Amounts
Original Plan - Category A
g Y Category B Category C
Revised Plan - Category A
g Y Category B Category C
Site Inspection — Date 1/12/2021
Notes Site grading complete, House location not staked.
G:\Forestry\ TreePreservation\Tree Preservation Plan Review - Individual lot.docx
Original Tree Preservation Plan Approved — Date 5/18/2020
Forwarded to Inspections — Date 1/14/2021
By
BY
Discussion/Meetings with Builder/Owner - Notes
Revised Tree Preservation Plan Approved — Date By
Forwarded to Inspections — Date By
Additional Field Inspections
Date Notes
Date Notes
Date Notes
Date Notes
G:\Forestry\ TreePreservation\Tree Preservation Plan Review - Individual Lot.docv
No
IZIME
PROPERTY LEGAL:
LOT SURVEY CHECKLIST FOR RESIDENTIAL
BUILDING PERMIT APPLICATION
Lot 3, Block 1, Schramm Meadows
/66 sus
DATE OF SURVEY: 1/4/21
LATEST REVISION: 1/13/21
ClD
DOCUMENT STANDARDS
• Registered Land Surveyor signature and company
• Building Permit Applicant
• Legal description
• Address
• North arrow and scale
• House type (rambler, walkout, split w/o, split entry, lookout, etc.)
• Directional drainage arrows with slope/gradient %
• Proposed/existing sewer and water services & invert elevation
• Street name
• Driveway (grade & width - in R/W and back of curb, 22' max.)
• Lot Square Footage
• Lot Coverage
ELEVATIONS
Existing
• Property corners
• Top of curb at the driveway and property line extensions
• Elevations of any existing adjacent homes
• Adequate footing depth of structures due to adjacent utility trenches
• Waterways (pond, stream, etc.)
Proposed
• Garage floor
• Basement floor
• Lowest exposed elevation (walkout/window)
• Property corners
• Front and rear of home at the foundation
• PRV Required
PONDING AREA (if applicable)
• Easement line
• NWL
• HWL
• Pond # designation
• Emergency Overflow Elevation
• Pond/Wetland buffer delineation
• Shoreland Zoning Overlay District
• Conservation Easements
DIMENSIONS
• Lot lines/Bearings & dimensions
• Right-of-way and street width (to back of curb)
• Proposed home dimensions including any proposed decks, overhangs greater than 2', porches, etc.
(i.e. all structures requiring permanent footings)
• Show all easements of record and any City utilities within those easements
• Setbacks of proposed structure and sideyard setback of adjacent existing structures
• Retaining wall requirements:
Reviewed By: Dave Westermayer
Date 1 /13/21
G:/1 Engineering/Forms/Cert. of Survey Checklist Fillable 6-28-19
Wl`no
z
0
0 1
aQ•
124,
,rT
W v
T�
ID1
0
W
H
M---I
H
O
O�
i O
tL j
cc0
CI m20
e Q o
err
ADDRESS: 690 MARIE COURT
DENOTES MAILBOX
MENT SET
DENOTES IRON PIPE M
D IRON PIPE MONUMENT
DENOTES FO
c
cn
a IS
DENOTES BITUMINOUS SURFACE
DENOTES PROPOSED DRAINAGE DIRECTION
SETBACK INFORMATION:
DENOTES SERVICE LOCATION
DENOTES WOOD HUB
0
FRONT - 30'
DENOTES EXISTING ELEVATION
0
SIDE YARD - 10' (HOUSE)
DENOTES PROPOSED ELEVATION
0
SIDE YARD - 5' (GARAGE)
DENOTES EXISTING CONTOUR
SIDE YARD - 40' (DODD RD)
DENOTES PROPOSED CONTOUR
REAR YARD - 15'
DENOTES DECIDUOUS TREE
DENOTES EVERGREEN TREE
DENOTES CONCRETE SURFACE
DENOTES GRAVEL SURFACE
N8
PROPERTY DESCRIPTION
LOT AREA = 35,031
I HEREBY CERTIFY THAT THIS SURVEY WAS PREPARED BY ME OR
UNDER MY DIRECT SUPERVISION AND THAT I AM A DULY LICENSED
LAND SURVEYOR UNDER THE LAWS OF THE STATE OF MINNESOTA.
IMPERVIOUS =
S:AProjects\Eagan\schramm mcadows\dwg\L3B1-cert.dwg 12/31/2020 3:02:33 PM CST
N
O) N
C) p)
CO C))
CO
N
rnU)
N C)
O X
O ),
a "
PERMIT
City of Eagan Permit Type:Building
Permit Number:EA169420
Date Issued:05/26/2021
Permit Category:ePermit
Site Address: 690 Marie Ct
Lot:3 Block: 1 Addition: Schramm Meadows
PID:10-67620-01-030
Use:
Description:
Sub Type:Fireplace
Work Type:Gas Fireplace (new)
Description:
Census Code:434 - Residential Additions, Alterations
Zoning:
Square Feet:0
Occupancy:
Construction Type:
Comments:Improvements to the home may require smoke detectors in all bedrooms. Chimney / flue must be inspected prior to
concealing.
Carbon monoxide detectors are required within 10 feet of all sleeping room openings in residential homes (Minnesota State
Valuation: 3,000.00
Fee Summary:BL - Base Fee $3K $88.50 0801.4085
Surcharge - Based on Valuation $3K $1.50 9001.2195
$90.00 Total:
I hereby acknowledge that I have read this application and state that the information is correct and agree to comply with all applicable State
of Minnesota Statutes and City of Eagan Ordinances.
Contractor:Owner:- Applicant -
Terin Elizabeth Robertson
690 Marie Ct
Eagan MN 55123
Glowing Hearth And Home Llc
100 Eldorado Dr.
Jordan MN 55352
(952) 492-9276
Applicant/Permitee: Signature Issued By: Signature