Loading...
690 Marie Ct6 L 56, in&46.se x0-00 EAGAN' 4o/' S ' 3830 PILOT KNOB ROAD I EAGAN, MN 55122-1810 JAN 1 1 2021 (651) 675-5675 I TDD: (651) 454-8535 I FAX: (651) 675-5694 buildinginspectionsacityofeagan.com tO /106 5-qv 2021 RESIDENTIAL BUILDING PERMIT APPLICATION &' o ill y Date: For Office Use i i Permit#: Permit Fee: /o Site Address: Date Received: / //' Staff: Unit #: Res a t! Qyy er Name: l t^ o ff.. OdvA►es Trrc Phone: 4(i- fSe_ o W Address / City / Zip: 4 K 6 b (,J e 4e -•41 ant y t 4*. /V14,►- SSI Z3 Applicant is: Id Owner 'r Contractor /,7/ 3 I/o GK / SC//,/2aw L Type of Work ' Description of work: t4 ew Colt-,VAi1f(j , ! I Construction Cost: Multi -Family Building: (Yes / No ) COnt AC Company: l Nves/h 41•''r►L) Z7e Contact: 11�4." t qq‘i Address: Weivit i+i rtiY./ City: tatty) State: MU Zip: Silo Phone:6141°'35 !7 Email: 17e10►00416441).4 License #: I 3 17 Lead Certificate #: If the project is exempt from lead certification, please explain why: In the last 12 months, Yes ' No COMPLETE THIS AREA ONLY IF CONSTRUCTING A NEW BUILDING has the City of Eagan issued a permit for a similar plan based on a master plan? If yes, date and address of master plan: Licensed Plumber: Mechanical Contractor: Sewer & Water Contractor: Fire Suppression Contractor: 57lIV[— tme' `l 11 Phone: Eft - Q t$ - 2'117 I' 7 ��eY grtn•�j Phone: 76 > • scli- I1 It t 0 plolvt,aceCO1 vbeiti Phone: 6L2-3 is9 - ger? Phone: NOTE: Plans and supporting documents that you submit are considered to be public information Portions of the Information,may be classified as non-public if you provide specific reasons that would permit the City to conclude that they are trade secrets.. You may subscribe to receive an electronic notification from the City of proposed ordinances by signing up for an email update on the City's website at www.citvofeaoan.com/subscribe. Exterior work authorized by a building permit issued in accordance with the Minnesota State Building Code must be completed within 180 days of permit issuance. CALL BEFORE YOU DIG. Call Gopher State One Call at (651) 454-0002 for protection against underground utility damage. Call 48 hours before you intend to dig to receive locates of underground utilities. www.gopherstateonecall.orq I hereby acknowledge that this information is complete and accurate; that the work will be in conformance with the ordinances and codes of the City Eagan; that I understand this is not a permit, but only an application for a permit, and work is not to start without a permit; that the work will accordance with the approved plan in the case of work which requires a review and approval of plans. X LZ , k Applicant's Printed Name Applicant's Signature SUB TYPES Foundation ASingle Family Multi 01 of _ Plex WORK TYPES Ni New ✓✓' Addition Alteration Replace DESCRIPTION Calculated Valuation Plan Review (25%_ 100°0 Census de # of Units # of Buildings Type of Construction FOR OFF CE USE ONLY Site Address: (QQ0 / l 6iz i E �r Fireplace Garage Deck Lower Level Repair Fire Repair Water Damage Egress Window REQUIRED INSPECTIONS /5 Footings (New Building) Footings (Deck) Footings (Addition) Foundation Foundation Before Backfill Roof: Ice Slater _Final Framing 30 Minutes N,4, 1 Hour Fireplace: y Rough In `/ir Test Final Insulation !` Sheathing Sheetrock Fire Walls y\ Braced Walls Shower Pan Reviewed By: RESIDENTIAL FEES Calculated Valuation Base Fee Plan Review State Surcharge MCES SAC City SAC Utility Connection Charge S&W Permit & Surcharge Treatment Plant Radio Read Other: opies: Porch (3-Season) Porch (4-Season) Porch (Screen/Gazebo/Pergola) Pool — Siding Reroof Windows — Solar Occupancy Code Edition Zoning Stories Square Feet Length Width Permit #: Miscellaneous Accessory Building Retaining Wall Move Building Demolish Building* *Demolition of entire building — give PCA handout to applicant MCES System SAC Units City Water Booster Pump PRV Fire Suppression Required Meter Size: Final / C.O. Required Final / No C.O. Required HVAC _ Service Test Gas Line Air Test _ Hood Pool: _Footings _Air/Gas Tests _Final Drain Tile Siding: _Stucco Lath Lath�Brick _ EFIS Windows Retaining Wall: _ Footings _ Backfill _ Final Radon Control Fire Suppression: _Rough In _Final Erosion Control Other: , Building Inspector Fes' ) /2S93,d,h! 61filfi lipl-Ps)`55)? V I (4 cic iifr-' 1970 k 9r,73' (ytoT31l9t' r.q 3 X � �, t� (g Sb 6-Ptj )77V/151 106/te-- /5".7 L-115/A9 Sri, �I �2 �►� TOTAL $ 0.00 New Construction Energy Code Compliance Certificate Per R401.3 Certificate. A building certificate shall be posted on or in the electrical distribution panel. Date Certificate Posted Address of the Dwelling or Dwelling Unit 690 Marie Ct City�7 .al arTf7Mailing [� 'L� Eagan Name of Residential Contractor Thorson Homes MN License Number 1317 HEATING A AIR CONDITONING THERMAL ENVELOPE RADON CONTROL,SYSTEM Total R-Value of all Types of Insulation Type: Check All That Apply X Passive (No Fan) c a) Active (With fan and mono meter or other system monitoring device) m N Location (or future location) of Fan: Non or Not Applicat Fiberglass, Blown Fiberglass, Batts Foam, Closed Cell Foam Open Cell Mineral Fiberboard Rigid, Extruded Poly Rigid, isocynurate Insulation Location Other Please Describe Here Below Entire Slab Foundation Wall 1O x Perimeter of Slab on Grade Rim Joist (1st Floor) TO f) x Rim Joist (2nd Floor+) 1004 X Wall to Ceiling, flat 49 X Ceiling, vaulted 1 qCI X Bay Windows or cantilevered areas x Floors over unconditioned area Describe other insulated areas Building envelope air tightness: Duct system air tightness: Windows & Doors Heating or Cooling Ducts Outside Conditioned Spaces Average U-Factor (excludes skylights and one door) U: L. 21 X Not applicable, all ducts located in conditioned space Solar Heat Gain Coefficient (SHGC): R-value MECHANICAL SYSTEMS Make up Air Select a Type Appliances HeatingSystem y Domestic Water Heater Cooling System X Not required per mech. code Fuel Type NATURAL GAS PA Cy , R410A Passive Manufacturer Carrier ACQ riki4 Carrier Powered Model 59SC5B080 CA13NA030 Interlocked with exhaust device. Describe: Rating or Size Input in STUS: 80,000 Capacity in Gallons: 7� Output n Tons: 2.5 Other, describe: Efficiency AFUE or HSPF% 95% SEER /EER 13 Location of duct or system: Residential Load Calculate Heating Loss Heating Gain Cooling Load 54,028 28,818 2.4 Cfm's " round duct OR MECHANICAL VENTILATION SYSTEM " metal duct Describe any additional or combined heating or cooling systems if installed: (e.g. two furnaces or air Combustion Air Select a Type source heat pump with gas back-up furnace): Not required per mech. code Select Type X Passive Heat Recover Ventilator (HRV) Capacity in cfms: Low: High: Other, describe: X Energy Recover Ventilator (ERV) Capacity in cfms: Low: 78 High: 155 Location of duct or system: Balanced Ventilation capacity in cfms: MECHANICAL ROOM Location of fan(s), describe: Cfm's Capacity continuous ventilation rate in cfms: 7 " round duct OR Total ventilation (intermittent + continuous) rate in cfms: 6 " metal duct Builders Associaton of Minnesota version 101014 Thorson Homes, 690 Marie Ct, Eagan 2015 Mechanical & Energy Code — Ventilation, Makeup, and Combustion Air Calculations Ventilation Quantity (Determine quantity by using Table R403.5.2 or Equation R403.5..2, 2015 Minnesota Energy Code) Square feet (Conditioned area including Basement — finished or unfinished) Number of bedrooms 3775 4 Total required ventilation Continuous ventilation 155 78 Directions - Determine the total and continuous ventilation rate by either using Table N1104.2 or equation 11-1. Insert the square footage, total required ventilation and continuous ventilation in the Mechanical Submittal form. The table and equation are below. Table R403.5.2 2015 Minnesota Energy Code Total and Continuous Ventilation Rates (in cfm) N Number of Bedrooms 1 2 3 4 5 6 Conditioned space (in sq. ft.) Total/ continuous Total/ continuous Total/ continuous Total/ continuous Total/ continuous Total/ continuous 1000-1500 60/40 75/40 90/45 105/53 120/60 135/68 1501-2000 70/40 85/43 100/50 115/58 130/65 145/73 2001-2500 80/40 95/48 110/55 125/63 140/70 155/78 2501-3000 90/45 105/53 120/60 135/68 150/75 165/83 3001-3500 100/50 115/58 130/65 145/73 160/80 175/88 3501-4000 110/55 125/63 140/70 155/78 170/85 185/93 4001-4500 120/60 135/68 150/75 165/83 180/90 195/98 4501-5000 130/65 145/73 160/80 175/88 190/95 205/103 5001-5500 140/70 155/78 170/85 185/93 200/100 215/108 5501-6000 150/75 165/;83 180/90 195/98 210/105 225/113 Enuatinn RAM g 9 9Mg nn: a .,_ . (0.02 x square feet of conditioned space) + [15 x (number of bedrooms + 1)] = Total ventilation rate (cfm) Example: (0.02 x 3000) +[15 x (3 + 1)] = Total ventilation rate = 120 cfm Total ventilation — The mechanical ventilation system shall provide sufficient outdoor air to equal the total ventilation rate average for each one -hour period according to the above table or equation. For heat recovery ventilators (HRV) and energy recovery ventilators (ERV) the average hourly ventilation capacity must be determined in consideration of any reduction of exhaust or outdoor air intake, or both, for defrost or other equipment cycling. Continuous ventilation - A minimum of 50 percent of the total ventilation rate, but not less than 40 cfm, shall be provided, on a continuous rate average for each one -hour period. The portion of the mechanical ventilation system intended to be continuously may have automatic cycling controls providing the average flow rate for each hour is met. 1 Thorson Homes, 690 Marie Ct, Eagan Directions - In order to determine the makeup air for ventilation, Table 501.4.1 must be filled out (see below). For most new installations, column A will be appropriate, however, if kitchen hoods exceed 300 cfm, atmospherically vented appliances or solid fuel appliances are installed, use the appropriate column. Please note, if the makeup air quantity is negative, no additional makeup air will be required for ventilation, if the value is positive refer to Table 501.4.2 and size the opening. Transfer the cfm, size of opening and type (round, rectangular, flex or rigid) to the last line of section D. The ventilation make-up air supply must communicate with the exhaust appliances. Table 501.4.1, 2015 Minnesota Mechanical Code PROCEDURE TO DETERM NE MAKEUP AIR QUANITY FOR EXHAUST APPLIANCES IN DWELLING UNITS (Additional makeup air will be required for combustion appliances, One or multiple power vent or direct vent appliances or no combustion appliances Column A see One or multiple fan- assisted appliances and power vent or direct vent appliances Column B KAIR method for calculations) One atmospherically vented gas or oil appliance or one solid fuel appliance Column C Multiple atmospherically vented gas or oil appliances or solid fuel appliances Column D 1.Enter the Appropriate Column to Estimate House Infiltration a) pressure factor (cfm/sf) 0.15 0.09 0.06 0.03 b) conditioned floor area (sf) (including unfinished basements) Estimated 3775 House Infiltration (cfm): Ma x 1bJ 566 2. Exhaust Capacity a) clothes dryer (cfm) 135 135 135 135 b) 80% of largest exhaust rating (cfm); 300 (not applicable if recirculating system or if powered makeup air is electrically interlocked and match to exhaust) 240 c) 80% of next largest exhaust rating (cfm); 80 (not applicable if recirculating system or if powered makeup air is electrically interlocked and matched to exhaust) Total 64 Exhaust Capacity (cfm); [2a + 2b +2c] 439 3. Makeup Air Quantity (cfm) a) total exhaust capacity (from above) b) 439 estimated house infiltration (from above) 566 Makeup Air Quantity (cfm); [3a — 3b] (if value is negative, no makeup air is needed) 4. -127 For makeup Air Opening Sizing, refer to Table 501.4.2 NSA A. Use this column if there are other than appliances. (Power vent and direct ves B. Use this column if there is one fan-assi may also be included.) C. Use this column if there is one atmospf fuel appliance. D. Use this column if there are multiple atr atmospherically vented gas or oil appli� fan -assisted or atmospherically vented gas or oil appliance or if there are no combustion y be used.) >ted appliance per venting system. (Appliances other than atmospherically vented appliances erically vented (other than fan -assisted) gas or oil appliance per venting system or one solid iospherically vented gas or oil appliances using a common vent or if there are nces and solid fuel appliances. t aooli Be advised: 2015 Minnesota Mechanical Code, Section 505.2, Installation of exhaust hood systems capable of exhausting in excess of 400 cfm shall be provide with makeup air at a rate approximately equal to the exhaust air rate. Such makeup air systems shall be equipped with a means of closure and shall be automatically controlled to start and operate simultaneously with the exhaust system. 3 Thorson Homes, 690 Marie Ct, Eagan IFGC Appendix E, Worksheet E-1 Residential Combustion Air Calculation Method (for Furnace, Boiler, and/or Water Heater in the Same Space) Step 1: Complete vented combustion appliance information. Furnace/Boiler: _ Draft Hood Fan Assisted X Direct Vent Input: 80,000 Btu/hr (not fan -assisted & Power Vent Water Heater: _ Draft Hood _X Fan Assisted Direct Vent Input: 75,000 Btu/hr (not fan -assisted) & Power Vent Step 2: Calculate the volume of the Combustion Appliance Space (CAS) containing combustion appliances. The CAS includes all spaces connected to one another by code compliant openings. CAS volume: 693 ft3 Step 3: Determine Air Changes per Hour (ACH)1 Default ACH values have been incorporated into Table E-1 for use with Method 4b (KAIR Method). If the year of construction or ACH is not known, use method 4a (Standard Method). Step 4: Determine Required Volume for Combustion Air. 4a. Standard Method Total Btu/hr input of all combustion appliances (DO NOT COUNT Input: 75,000 Btu/hr DIRECT VENT APPLIANCES) Use Standard Method column in Table E-1 to find Total Required TRV: 3750 ft3 Volume (TRV) If CAS Volume (from Step 2) is greater than TRV then no outdoor openings are needed. If CAS Volume (from Step 2) is less than TRV then go to STEP 5. 4b. Known Air Infiltration Rate (KAIR) Method Total Btu/hr input of all fan -assisted and power vent appliances Input: Btu/hr (DO NOT COUNT DIRECT VENT APPLIANCES) Use Fan -Assisted Appliances column in Table E-1 to find RVFA: ft3 Required Volume Fan Assisted (RVFA) Total Btu/hr input of all non -fan -assisted appliances Input: Btu/hr Use Non -Fan -Assisted Appliances column in Table E-1 to find RVNFA: ft3 Required Volume Non -Fan -Assisted (RVNFA) Total Required Volume (TRV) = RVFA + RVNFA TRV = + = ft3 If CAS Volume (from Step 2) is greater than TRV then no outdoor openings are needed. If CAS Volume (from Step 2) is less than TRV then go to STEP 5. Step 5: Calculate the ratio of available interior volume to the total required volume. Ratio = CAS Volume (from Step 2) divided by TRV (from Step 4a or Step 4b) Ratio = 693 / 3750 = .18 Step 6: Calculate Reduction Factor (RF). RF = 1 minus Ratio Ratio RF = 1 - .18 = .82 Step 7: Calculate single outdoor opening as if all combustion air is from outside. Total Btu/hr input of all Combustion Appliances in the same CAS Input: 75,000 Btu/hr (EXCEPT DIRECT VENT) Combustion Air Opening Area (CAOA): Total Btu/hr divided by 3000 Btu/hr per in2 CAOA = 75,000 / 3000 Btu/hr per in2 = 25 in2 Step 8: Calculate Minimum CAOA. Minimum CAOA = CAOA multiplied by RF Minimum CAOA = 25 x .82 = 20.5 in2 Step 9: Calculate Combustion Air Opening Diameter (CAOD) CAOD = 1.13 multiplied by the square root of Minimum CAOA CAOD = 1.13 q Minimum CAOA = 5.16 in 1 If desired, ACH can be determined using ASHRAE calculation or blower door test. Follow procedures in Section G304. Although this worksheet, IFGC Appendix E, Worksheet E-1 and the following worksheet, IFGC Appendix E, Table E-1, is referenced in the 2015 Minnesota Fuel Gas Code, these worksheets were not included in the published copy. 6" Hard Pipe 7" Flex Pipe 5 Robertson Residence HVAC Load Calculations for Thorson Homes Prepared By: Josh Schindele Flare Heating & Air Conditioning 9303 Plymouth Ave N Golden Valley, MN 55427 763-542-1166 Monday, January 4, 2021 Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Flare Heating & A/C Inc. Robertson Residence Golden Valley, MN 55427-3700 Page 2 Project Report General Project Information Project Title: Robertson Residence Designed By: Josh Project Date: Monday, November 16, 2020 Client Name: Thorson Homes Company Name: Flare Heating & Air Conditioning Company Representative: Josh Schindele Company Address: 9303 Plymouth Ave N Company City: Golden Valley, MN 55427 Company Phone: 763-542-1166 Company Fax: 763-542-3101 Company E-Mail Address: jschindele@flareheating.com Company Website: www.flareheating.com Design Data Reference City: Minneapolis/St. Paul AP, Minnesota Building Orientation: Front door faces East Daily Temperature Range: Medium Latitude: 44 Degrees Elevation: 834 ft. Altitude Factor: 0.970 Outdoor Outdoor Outdoor Indoor Indoor Grains Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference Winter: -16 -16.32 n/a n/a 72 n/a Summer: 93 71 34% 50% 72 22 Check Figures Total Building Supply CFM: 1,120 CFM Per Square ft.: 0.297 Square ft. of Room Area: 3,775 Square ft. Per Ton: 1,572 Volume (ft3): 30,897 Building Loads Total Heating Required Including Ventilation Air: 54,028 Btuh 54.028 MBH Total Sensible Gain: 24,279 Btuh 84 % Total Latent Gain: 4,539 Btuh 16 % Total Cooling Required Including Ventilation Air: 28,818 Btuh 2.40 Tons (Based On Sensible + Latent) Notes Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. S:\FHDATA\PROJECTS\JOSH\Version6\Thorson Homes, 690 Marie Ct, Eagan.rh9 Monday, January 4, 2021, 6:55 AM 16B-50: 21A-20: 20P-30: Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Flare Heating & A/C Inc. Robertson Residence Golden Valley, MN 55427-3700 Page 3, Total Building Summary Loads Component Area Sen Lat Sen Total Description Quan Loss Gain Gain Gain 2A-v-o: Glazing -Double pane low-e (e = 0.60), operable 393 10,030 0 8,421 8,421 window, vinyl frame, outdoor insect screen with 50% coverage, U-value 0.29, SHGC 0.22 11 N: Door -Metal - Polystyrene Core, U-value 0.35 38 1,170 0 426 426 15B0-10sf-4: Wall -Basement, , R-10 board insulation to 430 2,429 0 219 219 floor, no interior finish, 4' floor depth, U-value 0.054, above grade U-value 0.083 12F-0sw: Wall -Frame, R-21 insulation in 2 x 6 stud 2534 14,494 0 3,507 3,507 cavity, no board insulation, siding finish, wood studs, U-value 0.065 15B0-10sf-8: Wall -Basement, , R-10 board insulation to 675 3,185 0 107 107 floor, no interior finish, 8' floor depth, U-value 0.05, above grade U-value 0.083 12F1-0sw: Wall -Frame, R-21 open cell 1/2 lb. spray foam 315 1,802 0 436 436 insulation in 2 x 6 stud cavity, no board insulation, siding finish, wood studs, U-value 0.065 Roof/Ceiling-Under Attic with Insulation on Attic 1917 3,374 0 2,147 2,147 Floor (also use for Knee Walls and Partition Ceilings), Vented Attic, No Radiant Barrier, Dark Asphalt Shingles or Dark Metal, Tar and Gravel or Membrane, R-50 insulation, U-value 0.02 Floor -Basement, Concrete slab, any thickness, 2 1858 4,415 0 0 0 or more feet below grade, no insulation below floor, any floor cover, shortest side of floor slab is 20' wide, U-value 0.027 Floor -Over open crawl space or garage, Passive, 59 182 0 33 33 R-30 blanket insulation, any cover, U-value 0.035 Subtotals for structure: 41,081 0 15,296 15,296 People: 5 1,000 1,150 2,150 Equipment: 1,131 4,262 5,393 Lighting: 0 0 0 Ductwork: 0 0 0 0 Infiltration: Winter CFM: 121, Summer CFM: 89 11,409 1,280 1,984 3,264 Ventilation: Winter CFM: 78, Summer CFM: 78 1,538 1,128 367 1,495 Exhaust: Winter CFM: 150, Summer CFM: 150 AED Excursion: 0 0 1,220 1,220 Total Building Load Totals: 54,028 4,539 24,279 28,818 Check Figures Total Building Supply CFM: 1,120 CFM Per Square ft.: 0.297 Square ft. of Room Area: 3,775 Square ft. Per Ton: 1,572 Volume (ft3): 30,897 Building Loads Total Heating Required Including Ventilation Air: 54,028 Btuh 54.028 MBH Total Sensible Gain: 24,279 Btuh 84 Total Latent Gain: 4,539 Btuh 16 % Total Cooling Required Including Ventilation Air: 28,818 Btuh 2.40 Tons (Based On Sensible + Latent) Notes Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. S:\FHDATA\PROJECTS\JOSH\Version6\Thorson Homes, 690 Marie Ct, Eagan.rh9 Monday, January 4, 2021, 6:55 AM Rhvac - Residential & Light Commercial HVAC Loads Flare Heating & A/C Inc. Golden Valley, MN 55427-3700 s Building Pie Chart Building Loss 54,028 Btuh Building Gain 28,818 Btuh Floor 9% Roof 6%\ Wall 41% Glass 19% Ventilation 3% Elite Software Development, Inc. Robertson Residence Page 4 iInfiltration 21 Door 2% Wall 15%� Glass 29% Floor 0% Roof 7% ED Excursion 4% Ventilation 5% ,Infiltration 11 % People 7% Door 1 Equipment 19% S:\FHDATA\PROJECTS\JOSH\Version6\Thorson Homes, 690 Marie Ct, Eagan.rh9 Monday, January 4, 2021, 6:55 AM City Inspection Dept. Copy City Forester Copy Applicant/Builder Copy EAGAN INDIVIDUAL RESIDENTIAL LOT TREE PRESERVATION PLAN SUMMARY CITY OF EAGAN FORESTRY DIVISION 651-675-5300 (BUILDER, PLEASE READ ATTACHMENTS) Development Schramm Meadows Lot Number Address Builder 3 690 Marie Ct Block Number 1 Thorson Homes Inc Phone Number: (612) 810-3597 Contact: Brian Thorson Tree Protection Requirements: Replacement Trees: Tree Protection Fencing Installed on Site Oak Tree Pruning (Immediately seal wounds during April 1 to July 31) Therapeutic Pruning Required Retaining Wall To Be Installed Other: X Not Required: No Mitigation is Required for this Application Attachments: As Follows: X Yes (Refer to attache No Additional Notes: d eAGAN'eFORESTRY DIVISION REVIEWED BY oittit. - OA* DATE t -I -2o2,j 69 o Marie Ct Aerial Street Names Storm Basin Sections Numbers TREE PRESERVATION PLAN REVIEW — INDIVIDUAL LOT EAGAN Date Building Permit Application Received 1/12/2021 Development Schramm Meadows Site Address 690 Marie Court Builder Thorson Homes Telephone (612) -810-3597 Property/Lot Owner Name - Telephone - Lot 3 Block 1 Contact Brian Thorson E-mail brianathorsonhomes.corn E-mail - Office Plan Review — Date 1/12/2021 Notes No mitigation is required for this application Tree planting is encouraged and plantings must remain outside right-of-way setback. Tree protection must remain in place until construction completion. Tree Preservation Data Original Plan Revised Plan Total Significant Woodland Area sq. ft sq. ft Total Significant Trees Woodland To Be Removed sq. ft sq. ft Trees To Be Removed Allowable Woodland Removal (20%) sq. ft sq. ft Allowable Tree Removal (20%) Required Mitigation YES (or) NO Calculated Mitigation Amounts Original Plan - Category A g Y Category B Category C Revised Plan - Category A g Y Category B Category C Site Inspection — Date 1/12/2021 Notes Site grading complete, House location not staked. G:\Forestry\ TreePreservation\Tree Preservation Plan Review - Individual lot.docx Original Tree Preservation Plan Approved — Date 5/18/2020 Forwarded to Inspections — Date 1/14/2021 By BY Discussion/Meetings with Builder/Owner - Notes Revised Tree Preservation Plan Approved — Date By Forwarded to Inspections — Date By Additional Field Inspections Date Notes Date Notes Date Notes Date Notes G:\Forestry\ TreePreservation\Tree Preservation Plan Review - Individual Lot.docv No IZIME PROPERTY LEGAL: LOT SURVEY CHECKLIST FOR RESIDENTIAL BUILDING PERMIT APPLICATION Lot 3, Block 1, Schramm Meadows /66 sus DATE OF SURVEY: 1/4/21 LATEST REVISION: 1/13/21 ClD DOCUMENT STANDARDS • Registered Land Surveyor signature and company • Building Permit Applicant • Legal description • Address • North arrow and scale • House type (rambler, walkout, split w/o, split entry, lookout, etc.) • Directional drainage arrows with slope/gradient % • Proposed/existing sewer and water services & invert elevation • Street name • Driveway (grade & width - in R/W and back of curb, 22' max.) • Lot Square Footage • Lot Coverage ELEVATIONS Existing • Property corners • Top of curb at the driveway and property line extensions • Elevations of any existing adjacent homes • Adequate footing depth of structures due to adjacent utility trenches • Waterways (pond, stream, etc.) Proposed • Garage floor • Basement floor • Lowest exposed elevation (walkout/window) • Property corners • Front and rear of home at the foundation • PRV Required PONDING AREA (if applicable) • Easement line • NWL • HWL • Pond # designation • Emergency Overflow Elevation • Pond/Wetland buffer delineation • Shoreland Zoning Overlay District • Conservation Easements DIMENSIONS • Lot lines/Bearings & dimensions • Right-of-way and street width (to back of curb) • Proposed home dimensions including any proposed decks, overhangs greater than 2', porches, etc. (i.e. all structures requiring permanent footings) • Show all easements of record and any City utilities within those easements • Setbacks of proposed structure and sideyard setback of adjacent existing structures • Retaining wall requirements: Reviewed By: Dave Westermayer Date 1 /13/21 G:/1 Engineering/Forms/Cert. of Survey Checklist Fillable 6-28-19 Wl`no z 0 0 1 aQ• 124, ,rT W v T� ID1 0 W H M---I H O O� i O tL j cc0 CI m20 e Q o err ADDRESS: 690 MARIE COURT DENOTES MAILBOX MENT SET DENOTES IRON PIPE M D IRON PIPE MONUMENT DENOTES FO c cn a IS DENOTES BITUMINOUS SURFACE DENOTES PROPOSED DRAINAGE DIRECTION SETBACK INFORMATION: DENOTES SERVICE LOCATION DENOTES WOOD HUB 0 FRONT - 30' DENOTES EXISTING ELEVATION 0 SIDE YARD - 10' (HOUSE) DENOTES PROPOSED ELEVATION 0 SIDE YARD - 5' (GARAGE) DENOTES EXISTING CONTOUR SIDE YARD - 40' (DODD RD) DENOTES PROPOSED CONTOUR REAR YARD - 15' DENOTES DECIDUOUS TREE DENOTES EVERGREEN TREE DENOTES CONCRETE SURFACE DENOTES GRAVEL SURFACE N8 PROPERTY DESCRIPTION LOT AREA = 35,031 I HEREBY CERTIFY THAT THIS SURVEY WAS PREPARED BY ME OR UNDER MY DIRECT SUPERVISION AND THAT I AM A DULY LICENSED LAND SURVEYOR UNDER THE LAWS OF THE STATE OF MINNESOTA. IMPERVIOUS = S:AProjects\Eagan\schramm mcadows\dwg\L3B1-cert.dwg 12/31/2020 3:02:33 PM CST N O) N C) p) CO C)) CO N rnU) N C) O X O ), a " PERMIT City of Eagan Permit Type:Building Permit Number:EA169420 Date Issued:05/26/2021 Permit Category:ePermit Site Address: 690 Marie Ct Lot:3 Block: 1 Addition: Schramm Meadows PID:10-67620-01-030 Use: Description: Sub Type:Fireplace Work Type:Gas Fireplace (new) Description: Census Code:434 - Residential Additions, Alterations Zoning: Square Feet:0 Occupancy: Construction Type: Comments:Improvements to the home may require smoke detectors in all bedrooms. Chimney / flue must be inspected prior to concealing. Carbon monoxide detectors are required within 10 feet of all sleeping room openings in residential homes (Minnesota State Valuation: 3,000.00 Fee Summary:BL - Base Fee $3K $88.50 0801.4085 Surcharge - Based on Valuation $3K $1.50 9001.2195 $90.00 Total: I hereby acknowledge that I have read this application and state that the information is correct and agree to comply with all applicable State of Minnesota Statutes and City of Eagan Ordinances. Contractor:Owner:- Applicant - Terin Elizabeth Robertson 690 Marie Ct Eagan MN 55123 Glowing Hearth And Home Llc 100 Eldorado Dr. Jordan MN 55352 (952) 492-9276 Applicant/Permitee: Signature Issued By: Signature