693 Marie CtEAGA
3830 PILOT KNOB ROAD I EAGAN, MN 55122-1810
(651) 675-5675 I TDD: (651) 454-8535 I FAX: (651) 675-5694
buildinginspections ancitvofeagan.com
SSW /I --
2021 RESIDENTIAL BUILDING PERMIT APPLICATION
Date: 7 ' 2l'i.- �- I Site Address: 6a 3 Mettle Cocc..-t Unit #:
&/G7�7�-,
L /7.7.00/60 ,0 r For Office Use
Permit #: / ---70/ 4IL
Permit Fee. / Q7
Date Received:
Staff:
-57.'./
r< s is 13
FEB 2 4 zU21
ROwnert%
WCt���� �
Name: 1 111-'1'►.. 14.1‘m f 44, Phone: p f 1- 11514- 06Yi/
14(466 [A.4'i1 O-Z LAg� MA- mg
Address /City /Zip: 9tu�ai �s
Applicant is: ' Owner X Contractor S c.1/1 t2 Ft.l'1'1 IT M P et J (A) S
Type of Work
Description of work: tact., Ck+ t 4}to.
Construction Cost: Multi -Family Building: (Yes / No
)
Contractor
Company: ltA0•-f•,- bia,Mts 2 Contact: aelAn
Address: LW 6 4 (.JeJ. e.to of I2-1,lt City: titfdt'1
State: MAI Zip: 55.LtS Phone: f;it-VOM Email: l/7it+'+ 4w1'1"ef.tais,
License #: 11 tic Lead Certificate #:
If the project is exempt
from lead certification, please explain why:
In the last 12 months,
Yes Y No
COMPLETE THIS AREA ONLY IF CONSTRUCTING A NEW BUILDING
has the City of Eagan issued a permit for a similar plan based on a master plan?
If yes, date andTaddress of master plan:
Licensed Plumber:
Mechanical Contractor:
Sewer & Water Contractor:
Fire Suppression Contractor:
f �[a-+1-.`l4 Phone: 6s/' 9rs - Zq 77
S I'(vt' L✓e1
Fict•Y Pearit..9 Phone: 761 "5'IZ - 1 166
!Lilt., fate k tttPv4 A. Phone: "612 ' 3II - 141 a 7
Phone:
NOTE: Plans and supporting documents that you submit are considered to be public information. Portions of the information maybe
classified as.non public If you provide specific reasons that would permit the City to conclude that they are trade secrets.
You may subscribe to receive an electronic notification from the City of proposed ordinances by signing up for an email update on the City's
website at www.citvofeaoan.com/subscribe.
Exterior work authorized by a building permit issued in accordance with the Minnesota State Building Code must be completed within 180
days of permit issuance.
CALL BEFORE YOU DIG. CaII Gopher State One Call at (651) 454-0002 for protection against underground utility damage. Call 48 hours before you
intend to dig to receive locates of underground utilities. www.qopherstateonecall.orq
I hereby acknowledge that this information is complete and accurate; that the work will be in conformance with the ordinances and codes of the City of
Eagan; that I understand this is not a permit, but only an application for a permit, and work is not to start without a permit; that the work will be in
accordance with the approved plan in the case of work which requires a review and approval of plans.
x C L-s•--
x RA
Applicant's Printed Name
Applicant's Signature
FOR OFFICE USE ONLY
Site Address: �o � 11'1‹ t &
SUB TYPES
Foundation Fireplace
Single Family
Multi
01 of Plex
WORK TYPES
New Repair
Fire Repair
Water Damage
Egress Window
Garage
Deck
Lower Level
Addition
Alteration
Replace
DESCRIPTION
Calculated Valuation
Plan Review
(25%_ 100% )
Census Cokie
# of Units
# of Buildings
Type of Construction
‘arg
REQUIRED INSPECTIONS
Footings (New Building)
Permit #:
Porch (3-Season) _ Miscellaneous
Porch (4-Season) _ Accessory Building
Porch (Screen/Gazebo/Pergola)
Pool
Footings (Deck)
Footings (Addition)
Foundation, Foundation Before Backfill
Roof: _Ice & Water _Final
Framing 30 Minutes '1._ 1 Hour
Fireplace: Rough In \j Air Test \J, Final
Insulation d�
Sheathing
Sheetrock
Fire Walls
Braced Walls
Shower Pan
Reviewed By:
Siding
Reroof
Windows
— Solar
Occupancy
Code Edition
Zoning
Stories
Square Feet
Length
Width
Retaining Wall
Move Building
Demolish Building*
*Demolition of entire building — give PCA handout to
applicant
MCES System
T% SAC Units
City Water
Booster Pump
PRV
Fire Suppression Required
Meter Size:
Final / C.O. Required
Final / No C.O. Required
HVAC _ Service Test Gas Line Air Test Hood
Pool: _Footings _Air/Gas Tests _Final
Drain Tile
Siding: _Stucco Lath (Stone Latli/Brick EFIS
Windows
Retaining Wall: _ Footings _ Backfill Final
Radon Control
Fire Suppression: _Rough In _Final
Erosion Control
Other:
, Building Inspector
RESIDENTIAL FEES
Calculated Valuation
Base Fee
Plan Review
State Surcharge
MCES SAC
City SAC
Utility Connection Charge
S&W Permit & Surcharge
Treatment Plant
Radio Read
Other:
Copies:
/4-7e9Z' Rifvfkkiffq‘ y /4,07 /0/ 59)
(1)-(= r-Pv, 13,gyir;75=1;711191qii
)0/0 yi75 � /9,, 07,
Y 110, yl=)Vd()1
rstg;vife
32- )(0--- (7071?
n606
36�/,�N1,92
TOTAL $ 0.00
New Construction Energy Code Compliance Certificate
Per R401.3 Certificate. A building certificate shall be posted on or in the electrical distribution
panel.
Date Certificate Posted
amyl
1�,�
Mailing Address of the Dwelling or Dwelling Unit
693 Marie Ct
City
Eagan
;
HEATING
AT-
& AIR CONDITIONING
` 1r
Name of Residential Contractor
Thorson Homes
MN License Number
Tt. l' 11
THERMAL ENVELOPE
RADON CONTROL SYSTEM
Insulation Location
Total R-Value of all Types of
Insulation
Type. Check All That Apply
)!
Passive (No Fan)
Non or Not Applicable
Fiberglass, Blown
Fiberglass, Batts
a-
o
v
m
m
0
U
E
m
uo.
Foam Open Cell
Mineral Fiberboard
Rigid, Extruded Polystyrene
Rigid, Isocynurate
Active (With fan and monometer or other
system monitoring device)
Location (or future location) of Fan:
Other Please Describe Here
Below Entire Slab
Foundation Wall
10
X
Perimeter of Slab on Grade
Rim Joist (1st Floor)
ZO q
K
Rim Joist (2nd Floor+)
10.4
)C
Wall
1,0
)[
Ceiling, flat
4Cj
?(
Ceiling, vaulted
k
Bay Windows or cantilevered areas
K
Floors over unconditioned area
)(
Describe other insulated areas
_
Building envelope air tightness:
Duct system air tightness:
Windows & Doors
Heating or Cooling Ducts Outside Conditioned Spaces
Average U-Factor (excludes skylights and one door) U:
aci
X
Not applicable, all ducts located in conditioned space
Solar Heat Gain Coefficient (SHGC):
• 21-
R-value
MECHANICAL SYSTEMS
Make up Air Select a Type
Appliances
Heating System
Domestic Water
Heater
Cooling System
X
Not required per mech. code
Fuel Tye
pe
NATURAL GAS
�'[ G s
v P
R410A
Passive
Manufacturer
Carrier
Ato Cm-,.4,
Carrier
Powered
Model
59SC5B060
Pt tNdR
CA13NA030
Interlocked with exhaust device.
Describe:
Rating or Size
Input in
BTUS:
60,000
Capacity
in Gallons:
50
Output
in Tons:
2.5
Other, describe:
Efficiency
AFUE or
HSPF%
95°/0
SEER
/EER
13
Location of duct or system:
Residential Load Calculati(
Heating Loss
Heating Gain
Cooling Load
56,084
29,463
2.46
Cfm's
" round duct OR
MECHANICAL VENTILATION SYSTEM
" metal duct
Describe any additional or combined heating or cooling systems if installed: (e.g. two furnaces or air
source heat pump with gas back-up furnace):
Select Type
Combustion Air Select a Type
Not required per mech. code
X
Passive
Heat Recover Ventilator (HRV) Capacity in cfms:
Low:
High:
Other, describe:
X
Energy Recover Ventilator (ERV) Capacity in cfms:
Low:
78
High:
155
Location of duct or system:
MECHANICAL ROOM
Balanced Ventilation capacity in cfms:
Location of fan(s), describe:
Cfm's
Capacity continuous ventilation rate in cfms:
6
" round duct OR
Total ventilation (intermittent + continuous) rate in cfms:
5
" metal duct
Builders Associaton of Minnesota version 101014
Thorson Homes, 693 Marie Ct, Eagan
2015 Mechanical & Energy Code — Ventilation, Makeup, and Combustion Air
Calculations
Ventilation Quantity
(Determine quantity by using Table R403.5.2 or Equation R403.5..2, 2015 Minnesota Energy Code)
Square feet (Conditioned area including
Basement — finished or unfinished)
3984
Total required ventilation
155
Number of bedrooms
4
Continuous ventilation
78
Directions - Determine the total and continuous ventilation rate by either using Table N1104.2 or equation 11-1.
Insert the square footage, total required ventilation and continuous ventilation in the Mechanical Submittal form.
The table and equation are below.
Table R403.5.2 2015 Minnesota Energy Code
Total and Continuous Ventilation Rates (in cfm)
Number of Bedrooms
1
2
3
4
5
6
Conditioned space (in
sq. ft.)
Total!
continuous
Total/
continuous
Total/
continuous
Total/
continuous
Total/
continuous
Total/
continuous
1000-1500
60/40
75/40
90/45
105/53
120/60
135/68
1501-2000
70/40
85/43
100/50
115/58
130/65
145/73
2001-2500
80/40
95/48
110/55
125/63
140/70
155/78
2501-3000
90/45
105/53
120/60
135/68
150/75
165/83
3001-3500
100/50
115/58
130/65
145/73
160/80
175/88
3501-4000
110/55
125/63
140/70
155/78
170/85
185/93
4001-4500
120/60
135/68
150/75
165/83
180/90
195/98
4501-5000
130/65
145/73
160/80
175/88
190/95
205/103
5001-5500
140/70
155/78
170/85
185/93
200/100
215/108
5501-6000
150/75
165/;83
180/90
195/98
210/105
225/113
Equation R403.5.2 2015 Minnesota Energy Code
(0.02 x square feet of conditioned space) + [15 x (number of bedrooms + 1)] = Total ventilation rate (cfm)
Example: (0.02 x 3000) +[15 x (3 + 1)] = Total ventilation rate = 120 cfm
Total ventilation — The mechanical ventilation system shall provide sufficient outdoor air to equal the total
ventilation rate average for each one -hour period according to the above table or equation. For heat recovery
ventilators (HRV) and energy recovery ventilators (ERV) the average hourly ventilation capacity must be
determined in consideration of any reduction of exhaust or outdoor air intake, or both, for defrost or other
equipment cycling.
Continuous ventilation - A minimum of 50 percent of the total ventilation rate, but not Tess than 40 cfm, shall be
provided, on a continuous rate average for each one -hour period. The portion of the mechanical ventilation
system intended to be continuously may have automatic cycling controls providing the average flow rate for each
hour is met.
1
Thorson Homes, 693 Marie Ct, Eagan
Directions - In order to determine the makeup air for ventilation, Table 501.4.1 must be filled out (see below). For
most new installations, column A will be appropriate, however, if kitchen hoods exceed 300 cfm, atmospherically
vented appliances or solid fuel appliances are installed, use the appropriate column. Please note, if the makeup
air quantity is negative, no additional makeup air will be required for ventilation, if the value is positive refer to
Table 501.4.2 and size the opening. Transfer the cfm, size of opening and type (round, rectangular, flex or rigid)
to the last line of section D. The ventilation make-up air supply must communicate with the exhaust appliances.
Table 501.4.1, 2015 Minnesota Mechanical Code
PROCEDURE TO DETERM NE MAKEUP AIR QUANITY FOR EXHAUST APPLIANCES IN DWELLING UNITS
(Additional makeup air will be required for combustion appliances, see KAIR method for calculations)
One or multiple power
vent or direct vent
appliances or no
combustion appliances
Column A
One or multiple fan-
assisted appliances
and power vent or
direct vent appliances
Column B
One atmospherically
vented gas or oil
appliance or one solid
fuel appliance
Column C
Multiple
atmospherically
vented gas or oil
appliances or solid
fuel appliances
Column D
1.Enter the Appropriate Column to Estimate House Infiltration
a) pressure factor
(cfm/sf)
0.15
0.09
0.06
0.03
b) conditioned floor area (sf)
(including unfinished basements)
3984
Estimated House Infiltration (cfm):
[1a x 1b]
597
2. Exhaust Capacity
a) clothes dryer (cfm)
135
135
135
135
b) 80% of largest exhaust rating
(cfm); 300
(not applicable if recirculating
system or if powered makeup air is
electrically interlocked and match to
exhaust)
240
c) 80% of next largest exhaust
rating (cfm); 80
(not applicable if recirculating
system or if powered makeup air is
electrically interlocked and matched
to exhaust)
64
Total Exhaust Capacity (cfm);
[2a + 2b +2c]
439
3. Makeup Air Quantity (cfm)
a) total exhaust capacity (from
above)
439
b) estimated house infiltration (from
above)
597
Makeup Air Quantity (cfm);
[3a — 3b]
(if value is negative, no makeup air
is needed)
-158
4. For makeup Air Opening Sizing.
refer to Table 501.4.2
N/A
A. Use this column if there are other than fan -assisted or atmospherically vented gas or oil appliance or if there are no combustion
appliances. (Power vent and direct vent appliances may be used.)
B. Use this column if there is one fan -assisted appliance per venting system. (Appliances other than atmospherically vented appliances
may also be included.)
C. Use this column if there is one atmospherically vented (other than fan -assisted) gas or oil appliance per venting system or one solid
fuel appliance.
D. Use this column if there are multiple atmospherically vented gas or oil appliances using a common vent or if there are
atmospherically vented gas or oil appliances and solid fuel appliances.
Be advised: 2015 Minnesota Mechanical Code, Section 505.2, Installation of exhaust hood systems capable of
exhausting in excess of 400 cfm shall be provide with makeup air at a rate approximately equal to the exhaust air
rate. Such makeup air systems shall be equipped with a means of closure and shall be automatically controlled
to start and operate simultaneously with the exhaust system.
3
Thorson Homes, 693 Marie Ct, Eagan
IFGC Appendix E, Worksheet E-1
Residential Combustion Air Calculation Method
(for Fumace, Boiler, and/or Water Heater in the Same Space)
Step 1: Complete vented combustion appliance information.
Furnace/Boiler:
Draft Hood Fan Assisted X Direct Vent Input: 60,000 Btu/hr
_ _
(not fan -assisted & Power Vent
Water Heater:
Draft Hood X Fan Assisted Direct Vent Input: 75,000 Btu/hr
_
(not fan -assisted) & Power Vent
Step 2: Calculate the volume of the Combustion Appliance Space (CAS) containing combustion appliances.
The CAS includes all spaces connected to one another by code compliant openings. CAS volume: 972
ft3
Step 3: Determine Air Changes per Hour (ACH)1
Default ACH values have been incorporated into Table E-1 for use with Method 4b (KAIR Method). If the year
of construction or ACH is not known, use method 4a (Standard Method).
Step 4: Determine Required Volume for Combustion Air.
4a. Standard Method
Total Btu/hr input of all combustion appliances (DO NOT COUNT Input: 75,000 Btu/hr
DIRECT VENT APPLIANCES)
Use Standard Method column in Table E-1 to find Total Required TRV: 3750 ft3
Volume (TRV)
If CAS Volume (from Step 2) is greater than TRV then no outdoor openings are needed.
If CAS Volume (from Step 2) is less than TRV then go to STEP 5.
4b. Known Air Infiltration Rate (KAIR) Method
Total Btu/hr input of all fan -assisted and power vent appliances Input: Btu/hr
(DO NOT COUNT DIRECT VENT APPLIANCES)
Use Fan -Assisted Appliances column in Table E-1 to find RVFA: ft3
Required Volume Fan Assisted (RVFA)
Total Btu/hr input of all non -fan -assisted appliances Input: Btu/hr
Use Non -Fan -Assisted Appliances column in Table E-1 to find RVNFA: ft3
Required Volume Non -Fan -Assisted (RVNFA)
Total Required Volume (TRV) = RVFA + RVNFA TRV = + _ ft3
_
If CAS Volume (from Step 2) is greater than TRV then no outdoor openings are needed.
If CAS Volume (from Step 2) is less than TRV then go to STEP 5.
Step 5: Calculate the ratio of available interior volume to the total required volume. Ratio = CAS Volume (from
Step 2) divided by TRV (from Step 4a or Step 4b)
Ratio = 972 / 3750 = .26
Step 6: Calculate Reduction Factor (RF).
RF = 1 minus Ratio Ratio RF = 1 - .26 = .74
Step 7: Calculate single outdoor opening as if all combustion air is from outside.
Total Btu/hr input of all Combustion Appliances in the same CAS Input: 75,000 Btu/hr
(EXCEPT DIRECT VENT)
Combustion Air Opening Area (CAOA): Total Btu/hr divided
by 3000 Btu/hr per in2 CAOA = 75,000 / 3000 Btu/hr per in2 = 25 in2
Step 8: Calculate Minimum CAOA.
Minimum CAOA = CAOA multiplied by RF Minimum CAOA = 25 x .74 = 18.5
in2
Step 9: Calculate Combustion Air Opening Diameter (CAOD)
CAOD = 1.13 multiplied by the square root of Minimum CAOA CAOD = 1.13 d Minimum CAOA = 4.86
in
1 If desired, ACH can be determined using ASHRAE calculation or blower door test. Follow procedures in Section
G304.
Although this worksheet, IFGC Appendix E, Worksheet E-1 and the following worksheet, 1FGC Appendix E, Table
E-1, is referenced in the 2015 Minnesota Fuel Gas Code, these worksheets were not included in the published
copy.
5" Hard Pipe
6" Flex Pipe
5
693 Marie Ct
HVAC Load Calculations
for
Thorson Homes
Prepared By:
Josh Schindele
Flare Heating & Air Conditioning
9303 Plymouth Ave N
Golden Valley, MN 55427
763-542-1166
Monday, February 15, 2021
Rhvac is an ACCA approved Manual J, D and S computer program.
Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D.
Rhvac - Residential & Light Commercial HVAC Loads
Flare Heating & A/C Inc.
Golden Valley, MN 55427-3700
Elite Software Development, Inc.
693 Marie Ct
Page 2
Project Report
General Project Information
Project Title:
Designed By:
Project Date:
Client Name:
Company Name:
Company Representative:
Company Address:
Company City:
Company Phone:
Company Fax:
Company E-Mail Address:
Company Website:
693 Marie Ct
Josh
Monday, February 15, 2021
Thorson Homes
Flare Heating & Air Conditioning
Josh Schindele
9303 Plymouth Ave N
Golden Valley, MN 55427
763-542-1166
763-542-3101
jschindele@flareheating.com
www.flareheating.com
Design Data
Reference City:
Building Orientation:
Daily Temperature Range:
Latitude:
Elevation:
Altitude Factor:
Winter:
Summer:
44
834
0.970
Minneapolis/St. Paul AP, Minnesota
Front door faces East
Medium
Degrees
ft.
Outdoor Outdoor Outdoor Indoor Indoor Grains
Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference
-16 -16.32 n/a n/a 72 n/a
93 71 34% 50% 72 22
Check Figures
Total Building Supply CFM:
Square ft. of Room Area:
Volume (ft3):
1,144
3,984
30,952
CFM Per Square ft.:
Square ft. Per Ton:
0.287
1,623
Building Loads
Total Heating Required Including Ventilation Air:
Total Sensible Gain:
Total Latent Gain:
Total Cooling Required Including Ventilation Air:
56,084 Btuh
24,782 Btuh
4,681 Btuh
29,463 Btuh
56.084 MBH
84 %
16 %
2.46 Tons (Based On Sensible + Latent)
Notes
Rhvac is an ACCA approved Manual J, D and S computer program.
Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at
your design conditions.
S:\FHDATA\PROJECTS\JOSH\Version6\Thorson Homes, 693 Marie Ct, Eagan.rh9 Monday, February 15, 2021, 8:13 AM
Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc.
Flare Heating & A/C Inc. 693 Marie Ct
Golden Valley, MN 55427-3700 Page 3
Total Building Summary Loads
Component Area Sen Lat Sen Total
Description Quan Loss Gain Gain Gain
2A-v-o: Glazing -Double pane low-e (e = 0.60), operable 357 9,111 0 7,945 7,945
window, vinyl frame, outdoor insect screen with 50%
coverage, U-value 0.29, SHGC 0.22
11 N: Door -Metal - Polystyrene Core, U-value 0.35 38 1,170 0 426 426
12F-0sw: Wall -Frame, R-21 insulation in 2 x 6 stud 2490 14,242 0 3,447 3,447
cavity, no board insulation, siding finish, wood studs,
U-value 0.065
15B0-10sf-4: Wall -Basement, , R-10 board insulation to 250 1,533 0 195 195
floor, no interior finish, 4' floor depth, U-value 0.054,
above grade U-value 0.083
15B0-10sf-8: Wall -Basement, , R-10 board insulation to 1071 5,055 0 170 170
floor, no interior finish, 8' floor depth, U-value 0.05,
above grade U-value 0.083
12F1-0sw: Wall -Frame, R-21 open cell 1/2 Ib. spray foam 214 1,224 0 296 296
insulation in 2 x 6 stud cavity, no board insulation,
siding finish, wood studs, U-value 0.065
16B-50: Roof/Ceiling-Under Attic with Insulation on Attic 2010 3,538 0 2,251 2,251
Floor (also use for Knee Walls and Partition
Ceilings), Vented Attic, No Radiant Barrier, Dark
Asphalt Shingles or Dark Metal, Tar and Gravel or
Membrane, R-50 insulation, U-value 0.02
21A-20: Floor -Basement, Concrete slab, any thickness, 2 1974 4,690 0 0 0
or more feet below grade, no insulation below floor,
any floor cover, shortest side of floor slab is 20' wide,
U-value 0.027
20P-30: Floor -Over open crawl space or garage, Passive, 36 111 0 20 20
R-30 blanket insulation, any cover, U-value 0.035
Subtotals for structure: 40,674 0 14,750 14,750
People: 5 1,000 1,150 2,150
Equipment: 1,131 4,262 5,393
Lighting: 0 0 0
Ductwork: 0 0 0 0
Infiltration: Winter CFM: 148, Summer CFM: 98 13,872 1,422 2,205 3,627
Ventilation: Winter CFM: 78, Summer CFM: 78 1,538 1,128 367 1,495
Exhaust: Winter CFM: 150, Summer CFM: 150
AED Excursion: 0 0 2,048 2,048
Total Building Load Totals: 56,084 4,681 24,782 29,463
Check Figures
Total Building Supply CFM: 1,144 CFM Per Square ft.: 0.287
Square ft. of Room Area: 3,984 Square ft. Per Ton: 1,623
Volume (ft3): 30,952
Building Loads
Total Heating Required Including Ventilation Air: 56,084 Btuh 56.084 MBH
Total Sensible Gain: 24,782 Btuh 84 %
Total Latent Gain: 4,681 Btuh 16
Total Cooling Required Including Ventilation Air: 29,463 Btuh 2.46 Tons (Based On Sensible + Latent)
Notes
Rhvac is an ACCA approved Manual J, D and S computer program.
Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at
your design conditions.
S:\FHDATA\PROJECTS\JOSH\Version6\Thorson Homes, 693 Marie Ct, Eagan.rh9 Monday, February 15, 2021, 8:13 AM
Rhvac - Residential & Light Commercial HVAC Loads
Flare Heating & A/C Inc.
Golden Valley, MN 55427-3700
Elite Software Development, Inc.
693 Marie Ct
Page 4
Building Pie Chart
Building
Loss
56,084
Btu h
Building
Gain
29,463
Btuh
Roof 6%
Wall 39%
Wall 14%
Glass 27%
Floor 9%
Floor 0%
Roof 8%
Door 1
Ventilation 3%
/Infiltration 25%
Door 2%
Glass 16%
AED Excursion 7%
Ventilation 5%
People 7%
,Infiltration 12%
Equipment 18%
S:\FHDATA\PROJECTS\JOSH\Version6\Thorson Homes, 693 Marie Ct, Eagan.rh9 Monday, February 15, 2021, 8:13 AM
/‘ -77 71K
EAGAN
City Inspection Dept. Copy
City Forester Copy
Applicant/Builder Copy
INDIVIDUAL RESIDENTIAL LOT
TREE PRESERVATION PLAN SUMMARY
CITY OF EAGAN FORESTRY DIVISION
651-675-5300
(BUILDER, PLEASE READ ATTACHMENTS)
Development Schramm Meadows
Lot Number 5 Block Number 1
Address 693 Marie Ct
Builder Thorson Homes Inc
Phone Number: (612) 810-3597
Contact: Brian Thorson
Tree Protection Requirements:
Replacement Trees:
Tree Protection Fencing Installed on Site
Oak Tree Pruning (Immediately seal wounds during April 1 to July 31)
Therapeutic Pruning Required
Retaining Wall To Be Installed
Other:
X Not Required: No Mitigation is Required for this Application
As Follows:
Attachments:
X Yes (Refer to attach
No
Additional Notes:
d A' AKId C`5RESTRY DIVISION
REVIEWED
BY i%
DATE t/v / .ei
ADDRESS: 693 MARIE COURT
CERTIFICATE OF SURVEY
_. 9413
939—�
x 937
C�\
-- 9312
7
919.0
1T944a \ \ \ \
o DENOTES MAILBOX
O DENOTES IRON PIPE MONUMENT SET
• DENOTES FOUND IRON PIPE MONUMENT
— X DENOTES PROPOSED DRAINAGE DIRECTION
• DENOTES SERVICE LOCATION
O DENOTES WOOD BUB
060.0 DENOTES EXISTING ELEVATION
® DENOTES PROPOSED ELEVATION
DENOTES EXISTING CONTOUR
`alit
DENOTES DECIDUOUS TREE
DENOTES EVERGREEN TREE
DENOTES BITUMINOUS SURFACE
DENOTES CONCRETE SURFACE
DENOTES GRAVEL SURFACE
SETBACK INFORMATION:
FRONT = 30'
SIDE YARD = 10' (HOUSE)
SIDE YARD = 5' (GARAGE)
REAR YARD = 15'
Bohlen
Surveying & Associates
31432 F94g6 Avenn 1692 C6,Wad E.
Northfield. MN 56057
Remit MN 55137
Phone: (507) 6457768 A Phm64: (952)9966212
tomers
abohleneuiveylrmaam Fex: (962)BB86256
S\PmjecM\Fagen'echmmm meadow6Wwg(LSB1eatdwg 2/15/2021 4:49:16 PM CST
FOR
THORSON HOMES
123.26.S \
x 932.6
— x91
n 43151 --- 9
--
" y
+
x 937.3
CL \\\x 93 / x939.•
x 939.6
1"=20'
BENCHMARK:
FIRE HYDRANT AT END OF
MARE COURT, TNH — 949.96
NOTE: ALL BUILDING
D/MENSIONS ARE SHOWN TO
OUTSIDE OF FOUNDATION
WALL
LOT AREA = 13,476 SO. FT.
HOUSE AREA = 2,677 SO. FT.
PORCH AREA = 29 SO. FT.
SIDEWALK = 54 SO. FT.
DRNEW 4Y = 829 SO. FT.
IMPERVIOUS = 3,589 S0. FT.
= 26.6X
PROPOSED TOP OF WALL ELEV. = 948.7
PROPOSED GARAGE FLOOR ELEV. = 947.9
PROPOSED B4SE04ENT FLOOR ELEV. = 940.0
PROPERTY DESCRIPTION
LOT 5, BLOCK 1, SCRRAMM MEADOWS, CITY OF
EAGAN, DAKOTA COUNTY, MINNESOTA.
I HEREBY CERTIFY THAT THIS SURVEY WAS PREPARED BY ME OR
UNDER MY DIRECT SUPERVISION AND THAT I AM A DULY LICENSED
LAND SURVEYOR UNDER THE LAWS OF THE STATE OF MINNESOTA
DATE 2-19-2021
Tho1'w..1 c l3'lw &
THOMAS J. O'MEARA , LAND SURVEYOR
MINNESOTA LICENSE NO. 48187
TREE PRESERVATION PLAN REVIEW — INDIVIDUAL LOT
EAGAN
Date Building Permit Application Received
Development Schramm Meadows
Site Address 693 Marie Court
Builder Thorson Homes
Telephone (612) -810-3597
Property/Lot Owner Name -
Telephone -
Office Plan Review — Date 2/24/2021
2/26/2021
Lot 5
Contact Brian Thorson
Block 1
E-mail brian@thorsonhomes.com
E-mail -
Notes No Mitigation is required for this application
Tree planting is encouraged but planting location must remain outside of the right-of-way setback.
Tree protection should remain in place until construction completion.
Tree Preservation Data Original Plan Revised Plan
Total Significant Woodland Area sq. ft sq. ft
Total Significant Trees
Woodland To Be Removed sq. ft sq. ft
Trees To Be Removed
Allowable Woodland Removal (20%) sq. ft sq. ft
Allowable Tree Removal (20%)
Required Mitigation YES (or) NO
Calculated Mitigation Amounts
Original Plan - Category A Category B Category C
Revised Plan - Category A Category B Category C
Site Inspection — Date 2/26/2021 Notes Site grading complete and House location staked
G:\Forestry\TreePreservation\Tree Preservation Plan Review - Individual Lot.docx
Original Tree Preservation Plan Approved — Date 5/18/2020 By
a.°)1.
Forwarded to Inspections — Date 2/26/2021 By
Discussion/Meetings with Builder/Owner - Notes
Revised Tree Preservation Plan Approved — Date By
Forwarded to Inspections — Date By
Additional Field Inspections
Date Notes
Date Notes
Date Notes
Date Notes
G:\Forestry\TreePreservation\Tree Preservation Plan Review - Individual Lot.docx
Was the approved Tree Preservation Plan followed? YES (or) NO
If no, was additional mitigation required? YES (or) NO (If yes, describe additional mitigation below)
Final Site Inspection — Date Notes
Additional Notes and/or aerial photo image
(insert aerial image or draw map of site)
G:\Forestry\TreePreservation\Tree Preservation Plan Review - Individual Lot.docx
693 Marie Ct.
Aerial Street Names
Storm Basin
(0
w
Sections Numbers
CO
CO
U
a
O Z Q
0 ❑ ❑
0 ❑ ❑
0 ❑ ❑
O ❑❑
0 ❑ ❑
❑✓ ❑ ❑
0 ❑ ❑
0 ❑ ❑
0❑❑
O 00
O ❑❑
PROPERTY LEGAL:
LOT SURVEY CHECKLIST FOR RESIDENTIAL
BUILDING PERMIT APPLICATION
Lot 5, Block 1, Schramm Meadows
/‘ 72 7V
(093 141AQrE
DATE OF SURVEY: 2/19/21
LATEST REVISION:
DOCUMENT STANDARDS
• Registered Land Surveyor signature and company
• Building Permit Applicant
• Legal description
• Address
• North arrow and scale
• House type (rambler, walkout, split w/o, split entry, lookout, etc.)
• Directional drainage arrows with slope/gradient %
• Proposed/existing sewer and water services & invert elevation
• Street name
• Driveway (grade & width - in R/W and back of curb, 22' max.)
• Lot Square Footage
• Lot Coverage
ELEVATIONS
Existing
O ❑ ❑ • Property corners
✓❑ 0 ❑ • Top of curb at the driveway and property line extensions
,r❑ 0 0 • Elevations of any existing adjacent homes
O 0 0 • Adequate footing depth of structures due to adjacent utility trenches
0 0 0 • Waterways (pond, stream, etc.)
0❑❑
O ❑ ❑
O ❑❑
O ❑❑
O ❑❑
❑ 0 ❑
❑ 0 ❑
❑ 0❑
❑ 0 ❑
❑ 0❑
❑ 0❑
No
Proposed
• Garage floor
• Basement floor
• Lowest exposed elevation (walkout/window)
• Property corners
• Front and rear of home at the foundation
• PRV Required
PONDING AREA (if applicable)
• Easement line
• NWL
• HWL
• Pond # designation
• Emergency Overflow Elevation
• Pond/Wetland buffer delineation
• Shoreland Zoning Overlay District
• Conservation Easements
DIMENSIONS
O ❑ 0 • Lot lines/Bearings & dimensions
O 0 0 • Right-of-way and street width (to back of curb)
O 0 0 • Proposed home dimensions including any proposed decks, overhangs greater than 2', porches, etc.
(i.e. all structures requiring permanent footings)
0 0 0 • Show all easements of record and any City utilities within those easements
O 0 0 • Setbacks of proposed structure and sideyard setback of adjacent existing structures
O 0 0 • Retaining wall requirements:
Reviewed By: Dave Westermayer
Date 2/24/21
G:/1 Engineering/Forms/Cert. of Survey Checklist Fillable 6-28-19
ADDRESS: 693 MARIE COURT %qv
3:1 Maximum S
0,..
-edl -4
x 941.2
II1A%ERTRH cON !
1.7
945.3
0
0
•
x 937.2
383
939.0
x
943.7
ti
N
6
f.0
�—
—
CONCRETE CURB
ER
MARIE COURT
CENTER LINE
DENOTES MAILBOX
DENOTES IRON PIPE MONUMENT SET
DENOTES FOUND IRON PIPE MONUMENT
DENOTES PROPOSED DRAINAGE DIRECTION
DENOTES SERVICE LOCATION
DENOTES WOOD HUB
DENOTES EXISTING ELEVATION
DENOTES PROPOSED ELEVATION
DENOTES EXISTING CONTOUR
DENOTES DECIDUOUS TREE
DENOTES EVERGREEN TREE
DENOTES BITUMINOUS SURFACE
DENOTES CONCRETE SURFACE
DENOTES GRAVEL SURFACE
By
Date
x 939.1
PROPOSED
HOUSE x 939.9
FB/WO
946.3 x
CERTIFICATE OF SURVEY
FOR
THORSON HOMES
78°0948„w 123.
=asEME
938.0 x 937.1 �y
x 936.1
'x 946.6
SETBACK INFORMATION:
FRONT = 30'
SIDE YARD = 10' (HOUSE)
SIDE YARD = 5' (GARAGE)
REAR YARD = 15'
REVEWED
EAGAN ENGINEERING DEPT,
Bohlen
Surveying & Associates
31432 Foliage Avenue
Northfield, MN 55057
1682 Cliff Road E.
Burnsville, MN 55337
Phone: (507) 645-7768 Phone: (952) 895-9212
tomeara@bohlensurveying.com 71 Fax: (952) 895-9259
x 946.4
A
•
x 939.6
x 932.6
x 933.0 x 9:
x 933.1
x 934.9
x 939.
1"=20'
BENCHMARK:
FIRE HYDRANT AT END OF
MARIE COURT, TNH = 949.96
NOTE: ALL BUILDING
DIMENSIONS ARE SHOWN TO
OUTSIDE OF FOUNDATION
WALL
LOT AREA = 13,476 SQ. FT.
HOUSE AREA = 2,677 SQ. FT.
PORCH AREA = 29 SQ. FT.
SIDEWALK = 54 SQ. FT.
DRIVEWAY = 829 SQ. FT.
IMPERVIOUS = 3,589 SQ. FT.
= 26.6%
PROPOSED TOP OF WALL ELEV. = 948.7
PROPOSED GARAGE FLOOR ELEV. = 947.9
PROPOSED BASEMENT FLOOR ELEV. = 940.0
PROPERTY DESCRIPTION
LOT 5, BLOCK 1, SCHRAMM MEADOWS, CITY OF
EAGAN, DAKOTA COUNTY, MINNESOTA.
I HEREBY CERTIFY THAT THIS SURVEY WAS PREPARED BY ME OR
UNDER MY DIRECT SUPERVISION AND THAT I AM A DULY LICENSED
LAND SURVEYOR UNDER THE LAWS OF THE STATE OF MINNESOTA.
DATE: 2-19-2021 I f 10Tlad J. O e-CI LL
THOMAS J. O'MEARA, LAND SURVEYOR
MINNESOTA LICENSE NO. 46167
S:\Projects\Eagan\schramm meadows \dwg\L5B1-cert.dwg 2/15/2021 4:49:16 PM CST
PERMIT
City of Eagan Permit Type:Building
Permit Number:EA171545
Date Issued:08/20/2021
Permit Category:ePermit
Site Address: 693 Marie Ct
Lot:5 Block: 1 Addition: Schramm Meadows
PID:10-67620-01-050
Use:
Description:
Sub Type:Fireplace
Work Type:Gas Fireplace (new)
Description:
Census Code:434 - Residential Additions, Alterations
Zoning:
Square Feet:0
Occupancy:
Construction Type:
Comments:Improvements to the home may require smoke detectors in all bedrooms. Chimney / flue must be inspected prior to
concealing.
Carbon monoxide detectors are required within 10 feet of all sleeping room openings in residential homes (Minnesota State
Valuation: 3,000.00
Fee Summary:BL - Base Fee $3K $88.50 0801.4085
Surcharge - Based on Valuation $3K $1.50 9001.2195
$90.00 Total:
I hereby acknowledge that I have read this application and state that the information is correct and agree to comply with all applicable State
of Minnesota Statutes and City of Eagan Ordinances.
Contractor:Owner:- Applicant -
Janessa Collins
1416 Osceola Ave
Saint Paul MN 55105
Glowing Hearth And Home Llc
100 Eldorado Dr.
Jordan MN 55352
(952) 492-9276
Applicant/Permitee: Signature Issued By: Signature
PERMIT
City of Eagan Permit Type:Plumbing
Permit Number:EA174113
Date Issued:12/27/2021
Permit Category:ePermit
Site Address: 693 Marie Ct
Lot:5 Block: 1 Addition: Schramm Meadows
PID:10-67620-01-050
Use:
Description:
Sub Type:Residential
Work Type:Replace
Description:Water Softener
Meter Size Meter Type Manufacturer Serial Number Remote Number Line Size
Comments:Carbon monoxide detectors are required within 10 feet of all sleeping room openings in residential homes (Minnesota State
Building Code).
Please call Building Inspections at (651) 675-5675 to schedule a final inspection.
Fee Summary:PL - Permit Fee (WS &/or WH)$59.00 0801.4087
Surcharge-Fixed $1.00 9001.2195
$60.00 Total:
I hereby acknowledge that I have read this application and state that the information is correct and agree to comply with all applicable State
of Minnesota Statutes and City of Eagan Ordinances.
Contractor:Owner:- Applicant -
Janessa Collins
1416 Osceola Ave
Saint Paul MN 55105
Haferman Water Conditioning
12142 12th Ave.
Burnsville MN 55337
(952) 894-4040
Applicant/Permitee: Signature Issued By: Signature