Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
787 Summerbrooke Ct
pu.j to "� (c �- 1 / o U .. MC I o F((1V)Z — )o. o EAGAN '°"8 g +,.� - I (P: 3 3830 PILOT KNOB ROAD I EAGAN, MN 55122-1810 (651) 675-5675 I FAX: (651) 675-5694 buildindinspections uC�.citvofeadan.com R.EG EI ' '` L) FEB 22 2021 r For Office Use Permit #: (F'-'/ C _ -") Permit Fee (0 t toy K . 03 Date Received: Staff: 2021 RESIDENTIAL BUILDING PERMIT APPLICATION ke Ct • J Date: "—' --' — ' site Address: Resident/ Owner Name: Eternity Homes LLC ,P(D Phone: 651-460-3043 425 3rd St, Farmington / - /CM Address / City / Zip: I. ©7� `,�/ ��DL/ / ��r,l� Applicant is: Owner ✓ Contractor Owner Email: Type of Work Description of work: New Residential Single Family Home Construction Cost: $150,000 Multi -Family Building: (Yes / No X ) Contractor Eternity Homes LLC Contact: Ann Hamman Company: Address: 425 3rd St City: Farmington State: MN Zip: 55024 Phone: 651-460-3043 Email: drafting@eternityhomesllc.com License #: BC638704 Lead Certificate #: If the project is exempt from lead certification, please explain why: In the last 12 mfnths, Yes No COMPLETE THIS AREA ONLY IF CONSTRUCTING A NEW BUILDING has the City of Eagan issued a permit for a similar plan based on a master plan? If yes, date and address of master plan: 2111 Kings Rd, Eagan Licensed Plumber: Mechanical Contractor: Sewer & Water Contractor: Fire Suppression Contractor: Stewart Plumbing Inc Phone: 763-428-4833 Burnsville Heating & Air Phone: 952-894-0015 DSM Excavation Company Phone: 651-480-1355 Phone: NOTE Plans and supporting documents that you submit are considered to be public information. Portions of the information may be classified as non-public if you provide specific reasons that would permit the City to conclude that they are trade secrets. You may subscribe to receive an electronic notification from the City of proposed ordinances by signing up for an email update on the City's website at www.citvofeaaan.com/subscribe. CALL BEFORE YOU DIG. Contact Gopher State One Call at (651) 454-0002 or www.000herstateonecall.orq for protection against underground utility damage. Contact Gopher State One Call 48 hours before you intend to dig to receive locates of underground utilities. I hereby acknowledge that this information is complete and accurate; that the work will be in conformance with the ordinances and codes of the City of Eagan; that I understand this is not a permit, but only an application for a permit, and work is not to start without a permit; that the work will be in accordance with the approved plan in the case of work which requires a review and approval of plans. xCoral Ozmun Applicant's Printed Name Applicant's Signature L SUB TYPES Foundation Single Family Multi 01 of _ Plex ORK TYPES New Addition Alteration Replace DESCRIPTION Calculated Valuation Plan Review (25% 100% 1. ) Census Codel� #of Units # of Buildings Type of Construction FOR OFFICE USE ONLY Site Address: 1. Siti-0,1 C Fireplace Garage Deck Lower Level Repair Fire Repair Water Damage Egress Window REQUIRED INSPECTIONS Porch (3-Season) Porch (4-Season) Porch (Screen/Gazebo/Pergola) Pool Footings (New Building) Footings (Deck) Footings (Addition) Foundation x, Foundation Before Backfill Roof: _Ice & Water _Final Framing 30 Minutes 1 Hour Fireplace: )4 Rough In Air Test 44i Final Insulation Sheathing Sheetrock Fire Walls Braced Walls Shower Pan Reviewed By: Occupancy Code Edition Zoning Stories Square Feet Length Width Siding Reroof Windows Solar Permit #:) -t i0 59 Miscellaneous Accessory Building Retaining Wall Move Building Demolish Building* *Demolition of entire building — give PCA handout to applicant MCES System SAC Units City Water Booster Pump PRV Fire Suppression Required Meter Size: Final / C.O. Required Final / No C.O. Required HVAC Service Test Gas Line Air Test Hood Pool: _Footings _Air/Gas Tests Final Drain Tile Siding: Stucco Lath XStone Lath Brick EFIS Windows Retaining Wall: Footings Backfill Final Radon Control Fire Suppression: Rough In Final Erosion Control Other: , Building Inspector RESIDENTIAL FEES Calculated Valuation Base Fee Plan Review State Surcharge MCES SAC City SAC Utility Connection Charge S&W Permit & Surcharge Treatment Plant Radio Read Other: Copies: 6itsktuvrpe‘i I CA 6A5fiL ave ?C' 1 1 q `1 01 k" ?, t ,C{ F y/01 0 y9i,73 Y TOTAL $ 0.00 1 New Construction Energy Code Compliance Certificate Per R401.3 Certificate. A building certificate shall be posted on or in the electrical distribution panel. Date Certificate Posted 2/19/2021 Place your logo here Mailing Address of the Dwelling or Dwelling Unit 787 Summerbrooke City Eagan Name of Residential Contractor Eternity Homes LLC MN License Number BC638704 THERMAL ENVELOPE RADON CONTROL SYSTEM Insulation Location 'Total R-Value of all Types of Insulation Type. Check All That Apply X Passive (No Fan) Non or Not Applicable Fiberglass, Blown Fiberglass, Batts Foam, Closed Cell Foam Open Cell Mineral Fiberboard Rigid, Extruded Polystyrene Rigid, Isocynurate Active (With ran and monometer or other system monitoring device) Location (or future location) of Fan: Other Please Describe Here Below Entire Slab Foundation Wall 10 x Perimeter of Slab on Grade 15 X Rim Joist (1st Floor) 21 X Rim Joist (2nd Floor+) 21 x Wall 2A ale X_ Ceiling, flat 49 X Ceiling, vaulted 49 X X Bay Windows or cantilevered areas 30 X Floors over unconditioned area 30 X Describe other insulated areas Building envelope air tightness: Duct system air tightness: Windows & Doors Heating or Cooling Ducts Outside Conditioned Spaces Average U-Factor (excludes skylights and one door) U: 0.28 X Not applicable, all ducts located in conditioned space Solar Heat Gain Coefficient (SHGC): 0.22 R-value R-8 in garage area MECHANICAL SYSTEMS Make up Air Select a Type Appliances Heating System Domestic Water Heater Cooling System X Not required per mech. code Fuel Type Gas Electric R-410A Passive Manufacturer Daikin A.O Smith Daikin Powered Model DM92SE0603B PNT-50 DX13SNO24 Interlocked with exhaust device. Describe: Rating or Size Input in BTUS: 60,000 Capacity in Gallons: 50 Output in Tons: 2 Other, describe: Efficiency AFUE or HSPF% 92% SEER /EER 13 Location of duct or system: Residential Load Calculation Heating Loss Heating Gain Cooling Load 45,399 13,276 18,881 Cfm's " round duct OR MECHANICAL VENTILATION SYSTEM " metal duct Describe any additional or combined heating or cooling systems if installed: (e.g. two furnaces or air source heat pump with gas back-up furnace): Select Type Combustion Air Select a Type Not required per mech. code 6" Passive X Heat Recover Ventilator (HRV) Capacity in cfms: Low: 82 High: 190 Other, describe: Energy Recover Ventilator (ERV) Capacity in cfms: Low: High: Location of duct or system: Balanced Ventilation capacity in cfms: Location of fan(s), describe: Cfm's Capacity continuous ventilation rate in cfms: " round duct OR Total ventilation (intermittent + continuous) rate in cfms: " metal duct Builders Associaton of Minnesota version 101014 Rh rae 1i iderglar&t1 lit Cotn#.1.? 1$urn�v�lie �eafC�g 8�c �c. F � � [System 1, Zone 1 Summary Loads (Peak Load Procedure for Rooms) @` _ ..G..4�....�c ,< {` b�'i`.S �+'1n ia . 0 '. .."Y; '5. � �i' n. 'rL' .. bah: G azing-bah, ground reflectance = 0.23, u-value 20 487 0 150 150 0.28, SHGC 0.2 bah: Glazing -bah, ground reflectance = 0.23, u-value 48 1,170 0 632 632 0.28, SHGC 0.22 bah: Glazing -bah, ground reflectance = 0.23, u-value 25 587 0 201 201 0.27, SHGC 0.24 bah: Glazing -bah, ground reflectance = 0.23, u-value 42 987 0 330 330 0.27, SHGC 0.23 hbt: Door-hbt 20.4 266 0 73 73 hbt: Door-hbt 19 232 0 64 64 12F-0sw: Wall -Frame, R-21 insulation in 2 x 6 stud 1334.4 7,546 0 1,153 1,153 cavity, no board insulation, siding finish, wood studs Subtotals for structure: 11,275 0 3,298 3,298 People: 0 0 0 0 Equipment 0 1,200 1,200 Lighting: 0 0 0 Ductwork: 1,633 0 852 852 Infiltration: Winter CFM: 9, Summer CFM: 0 828 0 0 0 System 1, Zone 1 Load Totals: 13,736 0 5,452 5,452 Supply Square Volume CFM: 255 CFM Per Square ft.: 0.221 ft. of Room Area: 1,157 Square ft. Per Ton: 2,546 (ft3) of Cond. Space: 12,149 ,}y ,r^+fp l� a+,-N 1....�e?L �H:' �r %.eH � ,...�..£ Z -- .'.���' .xC` . i ..5v� -'k'Y"b�+'^ #IYxjeN.0 V" �4i3y Y '+5."eYe'vK Wu v+i=A"""` s3' xkn' '5�-- aSX +5� Sy +J^ h�.°G��'y-:� +!. � �.�9'S��� v�...�7N7�.i � `Fg3'+Y � �2�' h:Tu4 CSY Y Fi' � �d ���.t¢b, .�r��n'�``� , Total Heating Required: 13,736 Btuh 13.736 MBH Total Sensible Gain: 5,452 Btuh 100 % Total Latent Gain: 0 Btuh 0 % Total Cooling Required: 5,452 Btuh 0.45 Tons (Based On Sensible + Latent) ,`6i.i'e. 144x ..,3.-` - IX. `=¢#Y `-+£. s&Xi_ .. .. n..h ._ Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. \\badata\RedirectedFolders ...\NJJ The San Fran 2021 SW.rhv Friday, February 19, 2021, 3:27 PM rribm System 1, Zone 2 Summary Loads (Peak Load Procedure for Rooms) bah: Glazing -bah, ground reflectance = 0.23, u-value 47.5 0.28, SHGC 0.2 bah: Glazing -bah, ground reflectance = 0.23, u-value 45.5 0.28, SHGC 0.22 bah: Glazing -bah, ground reflectance = 0.23, u-value 11.6 0.26, SHGC 0.24 12F-Osw: Wall -Frame, R-21 insulation in 2 x 6 stud 1108.2 cavity, no board insulation, siding finish, wood studs R-49-ad: Roof/Ceiling-Under Attic with Insulation on Attic 1263.4 Floor (also use for Knee Walls and Partition Ceilings), Custom, R-49, dark asphalt Subtotals for structure: People: Equipment: Lighting: Ductwork: Infiltration: Winter CFM: 7, Summer CFM: 0 System 1, Zone 2 Load Totals: 5 0 1,156 0 851 851 1,108 0 403 403 263 0 221 221 6,265 0 959 959 2,199 0 1,213 1,213 10,991 0 4,324 4,324 1,150 1,500 2,650 400 0 400 0 0 1,572 0 1,103 1,103 665 0 0 0 13,229 1,550 7,060 8,610 Supply CFM: Square ft. of Room Area: Volume (ft3) of Cond. Space: Total Heating Required: Total Sensible Gain: Total Latent Gain: Total Cooling Required: 331 CFM Per Square ft.: 1,263 Square ft. Per Ton: 10,107 13,229 Btuh 13.229 MBH 7,060 Btuh 82 % 1,550 Btuh 18 % 8,610 Btuh 0.72 Tons (Based On Sensible + Latent) awa 0.262 1,760 Nc ISM Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. \\bhdata\RedirectedFolders ...\NJJ The San Fran 2021 SW.rhv Friday, February 19, 2021, 3:27 PM Ridt{etr,yx,.l�fnhJctCgr Iy$01014. a�pt11 Bum• YF ( p1l/ { System 1, Zone 3 Summary Loads (Peak Load Procedure for Rooms) ynj©R rs� V ., � �" Spa�z-`n,Pt4�`£' $ ,..v 4'TT.,u,� g bah: Glazing -bah, ground reflectance = 0.23, u-value 35 852 0 274 274 0.28, SHGC 0.22 bah: Glazing -bah, ground reflectance = 0.23, u-value 42 987 0 330 330 0.27, SHGC 0.23 12F-Osw: Wall -Frame, R-21 insulation in 2 x 6 stud 453 2,560 0 392 392 cavity, no board insulation, siding finish, wood studs 1580-15sf-8: Wall -Basement, , R-15 board insulation to 800 2,923 0 0 0 floor, no interior finish, 8' floor depth 21A-20-v: Floor -Basement, Concrete slab, any thickness, 1200 2,819 0 0 0 2 or more feet below grade, no insulation below floor, vinyl covering, shortest side of floor slab is 20' wide Subtotals for structure: 10,141 0 1,228 1,228 People: 0 0 0 0 Equipment: 0 0 0 Lighting: 0 0 0 Ductwork: 1,407 0 232 232 Infiltration: Winter CFM: 3, Summer CFM: 0 290 0 0 0 System 1, Zone 3 Load Totals: 11,838 0 1,489 1,489 Supply CFM: 70 CFM Per Square ft.: 0.058 Square ft. of Room Area: 1,200 Square ft. Per Ton: 9,674 Volume (ft3) of Cond. Space: 11,400 k }. k £WM l ^v+,S,,.., "-5��`� i` f. „'S"SI ' 'I�-+ yy2wt'- '4 a '". � Y'i "S 7 L "T},,��' }y>'" -" 'w^'$°, y s°,S By ¢ `, ...T-'x5'"��w�$��'-+�t sF��`d,.-.°, �" ' a-'�b'r ..,.:` n-�rdt?i.'c'i S Yi.f•`a' %yin f�^ - k'�'�.: 4 .� -.. ` �.... ..: v 3, i��'3'vT.-C Total Heating Required: 11,838 Btuh 11.838 MBH Total Sensible Gain: 1,489 Btuh 100 % Total Latent Gain: 0 Btuh 0 % Total Cooling Required: 1,489 Btuh 0.12 Tons (Based On Sensible + Latent) Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. \\bhdata\RedirectedFolders ...\NJJ The San Fran 2021 SW.rhv Friday, February 19, 2021, 3:27 PM Rhvac V_Burrsrnl i Btimsv l j Detailed Room Loads - Room 17 - Basement (Peak Fenestration Gain Procedure) Room is in zone 3, which peaks at 3 pm Calculation Mode: Htg. & clg. Room Length: 30.0 Room Width: 40.0 Area: Ceiling Height: Volume: Number of Registers: Runout Air: Runout Duct Size: Runout Air Velocity: Runout Air Velocity: Actual Loss: -Wall-12F-0sw 40 X 8 S -Wall-15B0-15sf-8 40 X 8 E -Wall-15B0-15sf-8 30 X 8 W -Wall-15B0-15sf-8 30 X 8 N -Wall-12F-0sw 40 X 1.5 S -Wall-12F-0sw 40 X 1.5 E -Wall-12F-0sw 30 X 1.5 W -Wall-12F-0sw 30 X 1.5 N -GIs-bah shgc-0.22 0%S (2) N -GIs-bah shgc-0.23 0%S Floor-21A-20 40 X 30 Subtotals for Structure: Infil.: Win.: 3.1, Sum.: 0.0 Ductwork: AED Excursion: Room Totals: 1,200.0 9.5 11,400.0 1 70 5 511 511 0.210 ft. ft sq.ft. ft. cu.ft. CFM in. ft./min. ft./min. in.wg./100 ft. Occurrences: System Number: Zone Number: Supply Air. Supply Air Changes: Req. Vent. Clg: Actual Winter Vent.: Percent of Supply.: Actual Summer Vent.: Percent of Supply: Actual Winter Infil.: Actual Summer Infil.: 243 0.065 5.7 1,374 0.9 320 0.042 3.7 1,169 0.0 240 0.042 3.7 877 0.0 240 0.042 3.7 877 0.0 60 0.065 5.7 339 0.9 60 0.065 5.7 339 0.9 45 0.065 5.7 254 0.9 45 0.065 5.7 254 0.9 35 0.280 24.4 852 10.7 42 0.270 23.5 987 11.0 1200 0.027 2.3 2,819 0.0 10,141 530 0.547 290 0.000 1,407 11,838 1 1 3 70 CFM 0.4 AC/hr 0 CFM 59 CFM 84 % 20 CFM 29 % 3 CFM 0 CFM 0 0 0 0 0 0 0 52 0 52 0 39 0 39 0 376 0 460 0 0 0 1,228 0 0 232 28 0 1,489 1\badata\RedirectedFolders ...\NJJ The San Fran 2021 SW.rhv Friday, February 19, 2021, 3:27 PM Rhvac Residential & Light Commercial ►AC Loads Elite Software Development, Inc` Buts`v�vl a Heating�l�8�AXC Inc k "F1fe 5a Fran i-Bumsville, MN 5533Li t 5. e System 9 Room Load Summary S � � $4 6.. '''°...� , ny _ X• � 3 fi ® r.\�� J+� .��. xb !Y }- tiry a+ yy.. e ., ?:S::.uy. .tSaPra?...w. "xh(' ')_a.`.a :...--,:a.; --Zone 1- -Zone 1 Foyer 149 1,379 18 1-3 349 366 0 17 17 2 Study 120 1,945 26 1-4 333 619 0 29 29 3 Great Room 320 3,592 48 1-5 309 898 0 42 42 4 Dining 160 1,590 21 1-3 547 573 0 27 27 5 Kitchen 192 1,775 24 1-5 628 1,827 0 86 86 6 Mud Room 108 2,657 36 1-4 564 1,050 0 49 49 7 Powder Room 108 798 11 1-2 255 119 0 6 6 Zone 1 subtotal 1,157 13,736 184 5,452 0 255 255 --Zone 2-- 8 Bedroom 2 158 2,103 28 1-5 545 1,587 230 74 74 9 Wic 36 747 10 1-2 305 142 0 7 7 10 Bedroom 3 192 1,988 27 1-4 515 960 230 45 45 11 Bath 1 78 470 6 1-2 297 138 0 6 6 12 Stairs 112 724 10 1-2 731 341 0 16 16 13 Laundry 93 813 11 1-3 413 433 400 20 20 14 Master Bedroom 230 2,803 38 1-6 478 2,005 460 94 94 15 Master Bath 190 2,056 28 1-3 552 578 0 27 27 16 Bedroom 4 174 1,524 20 1-4 471 876 230 41 41 Zone 2 subtotal 1,263 13,229 177 7,060 1,550 331 331 ---Zone 3- 17 Basement 1,200 11,838 158 1-5 511 1,489 0 70 70 Zone 3 subtotal 1,200 11,838 158 1,489 0 70 70 Ventilation 6,596 879 3,708 Duct Latent 348 System 1 total 3,620 45,399 519 13,276 5,606 581 581 System 1 Main Trunk Size: 9x13 in. Velocity: 715 ft./min Loss per 100 ft.: 0.103 in.wg Note: Since the system is multizone, the Peak Fenestration Gain Procedure was used to determine glass sensible gains at the room and zone levels, so the sums of the zone sensible gains and airflows for cooling shown above are not intended to equal the totals at the system level. Room and zone sensible gains and cooling CFM values are for the hour in which the glass sensible gain for the zone is at its peak. Sensible gains at the system level are based on the "Average Load Procedure + Excursion" method. '"/ U- p �e��a� 1 y �!'3�.Y 'y %` � e ._y,. Y".+^` Net Required: 1.57 70% / 30% 13,276 5,606 18,881 \\badata1RedirectedFolders ...\NJJ The San Fran 2021 SW.rhv Friday, February 19, 2021, 3:27 PM Burnsville Heating & Air Conditioning, Inc. 3451 W. Burnsville Pkwy, Suite 120, Burnsville, MN 55337 Phone 952-894-0005 — Fax 952-894-0925 — Web www.burnsvilleheating.com Ventilation, Makeup and Combustion Air Calculations Submittal Form for New Dwellings Site address 787 Summerbrooke Ct Date 2/19/2021 Contractor Burnsville Heating & Air Conditioning, Inc Completed By Alan Dobson VENTILATION REQUIREMENTS TABLE R403.5.2 NUMBER OF BEDROOMS 1 2 3 4 5 62 Conditioned spacel (in sq. ft.) Total/ Continuous Total/ Continuous Total/ Continuous Total/ Continuous Total/ Continuous Total/ Continuous 1000-1500 60/40 75/40 90/45 105/53 120/60 135/68 1501-2000 70/40 85/43 100/50 115/58 130/65 145/73 2001-2500 80/40 95/48 110/55 125/63 140/70 155/78 2501-3000 90/40 105/53 120/60 135/68 150/75 165/83 3001-3500 100/50 115/58 130/65 145/73 160/80 175/88 3501-4000 110/55 125/63 140/70 155/78 170/85 185/93 4001-4500 120/60 135/68 150/75 165/83 180/90 195/98 4501-5000 130/65 145/73 160/80 175/88 190/95 205/103 5001-5500 140/70 155/78 170/85 185/93 200/100 215/108 5501-6000 2 150/75 165/83 180/90 195/98 210/105 225/113 1. Conditioned space includes the basement and conditioned crawl spaces. 2. If conditioned space exceeds 6000sp. Ft. or there are more than 6 bedrooms, use Equation R403.5.2 R403.5.2 Total Ventilation rate. The mechanical ventilation system shall provide sufficient outdoor air to equal the total ventilation rate average for each 1- hour period in accordance with Table R403.5.2, or Equation 403.5.2, based on the number of bedrooms and square footage of conditioned space, including the basement and conditioned crawl spaces. For the purposes of Table R403.5.2 and Section R403.5.3, the following applies" a. Equation R403.5.2 Total ventilation rate: Total ventilation rate (cfm) = (0.02 x square feet of conditioned space) + (15 x (number of bedrooms =1)) b. Equation R403.5.2.1 Continuous ventilation rate: Continuous ventilation rate (cfm) = Total ventilation rate/2 Amount Total 155 Amount Continuous 78 BURNSVILLE Heating & Air Conditioning, Inc. TABLE 304.1 COMBUSTION AIR REQUIREMENTS FOR GAS -FIRED APPLIANCES WHEN THE COMBINED INPUT IS UP TO AND INCLUDING 400,000 Btu/hr TOTAL INPUT OF APPLIANCESi, THOUSANDS OF Btu/hr (kW) REQUIRED FREE AREA OF AIR- SUPPLY OPENING OR DUCT, SQUARE INCHES (sq mm) ACCEPTABLE APPROXIMATE ROUND DUCT EQUIVALENT DIAMETERz, INCH (mm) 25 (8) 7 (4,500) 3 (75) 50 (15) 7 (4,500) 3 (75) 75 (23) 11 (7,000) 4 (100) 100 (30) 14 (9,000) 4 (100) 125 (37) 18 (12,000) 5 (125) 150 (45) 22 (14,000) 5 (125) 175 (53) 25 (16,000) 6 (150) 200 (60) 29 (19,000) 6 (150) 225 (68) 32 (21,000) 6 (150) 250 (75) 36 (23,000) 7 (175) 275 (83) 40 (26,000) 7 (175) 300 (90) 43 (28,000) 7 (175) 325 (98) 47 (30,000) 8 (200) 350 (105) 50 (32,000) 8 (200) 375 (113) 54 (35,000) 8 (200) 400 (120) 58 (37,000) 9 (225) 1. For total inputs falling between listed capacities, use next largest listed input. 2. If flexible duct is used, increase the duct diameter by one inch. * *Flexible duct shall be stretched with minimal sags. BTU Amount for Non -direct vent appliances BtJRNSVILLE Heating & Air Conditioning, Inc. IFGC Appendix E, Worksheet E-1 Residential Combustion Air Calculation Method (for Furnace, Boiler, and/or Water Heater in the Same Space) Step 1: Complete vented combustion appliance information. Furnace/Boiler: `,4 / -,� _Draft Hood _Fan Assisted Direct Vent Input Lk//Yti-/1 (Not fan assisted) & Power Vent Btu/hr Water Heater: / ,/yyl/\Y�, Draft Hood _Fan Assisted _Direct Vent Input: L V', 1��J (Not fan assisted) &Power Vent _Electric _Btu/hr Step 2: Calculate the volume of the Combustion Appliance Space (CAS) containing combustion appliances. The CAS includes all spaces connected to one another by code compliant openings. CAS volume: ft3 Step 3: Determine Air Changes per Hours (ACH)1 Default ACH values have been incorporated into Table E-1 for use with Method 4b (KAIR Method). If the year of construction or ACH is not known, use method 4a (Standard Method). Step 4: Determine Required Volume for Combustion Air. 4a. Standard Method Total Btu/hr input of all combustion appliances Input: Btu/hr (DO NOT COUNT DIRECT VENT APPLIANCES) Use Standard Method column in Table E-1 to find Total Required Volume (TRV) TRV: ft3 If CAS Volume (from Step 2) is greater than TRV then no outdoor openings are needed. If CAS Volume (from Step 2) is less than TRV then go to STEP 5. 4b. Known Air Infiltration Rate (KAIR) Method Total Btu/hr input of all fan -assisted and power vent appliances Input: Btu/hr (DO NOT COUNT DIRECT VENT APPLIANCES) Use Fan -Assisted Appliances column in Table E-1 to find Required Volume Fan Assisted (RVFA) RFVA: ft3 Total Btu/hr input of all non -fan -assisted appliances Input: Btu/hr Use Non -Fan -Assisted Appliances column in Table E-1 to find Required Volume Non -Fan -Assisted (RVNFA) RVNFA: ft3 Total Required Volume (TRV) = RVFA + RVNFA RV= + = ft3 If CAS Volume (from Step 2) is greater than TRV then no outdoor openings are needed. If CAS Volume (from Step 2) is less than TRV then go to STEP 5. Step 5: Calculate the ratio of available interior volume to the total required volume. Ratio = CAS Volume (from Step 2) divided by TRV (from Step 4a or Step 4b) Ratio = / = Step 6: Calculate Reduction Factor (RF). RF - 1 minus Ratio RF = 1 - = Step 7: Calculate single outdoor opening as if all combustion air is from outside. Total Btu/hr input of all Combustion Appliances in the same CAS (EXCEPT DIRECT VENT) Input: Btu/hr Combustion Air Opening Area (CAOA): Total Btu/hr divided by 3000 Btu/hr per in' CAOA = /3000 Btu/hr per in2= in' Step 8: Calculate Minimum CAOA. Minimum CAOA = CAOA multiplied by RF Minimum CAOA = x in2 Step 9: Calculate Combustion Air Opening Diameter (CAOD) CAOD = 1.13 multiplied by the square root of Minimum CAOA CAOD = 1.13 d Minimum CAOA = in. 1 If desired, ACH can be determined using ASHRAE calculation or blower door test. Follow procedures in Section G304. BURNSVILLE Heating & Air Conditioning, Inc. IFGC Appendix E, Table E-1 Residential Combustion air (Required Interior Volume Based on Input Rating of Appliance) Input Rating (Btu/hr) Standard Method (ft3) Known Fan Assisted 19941 to present Air Infiltration Rate Pre-1994 (KAIR) Method (ft3) I Non -Fan 1994 to present -Assisted Pre-1994 5,000 250 375 188 525 263 10,000 500 750 375 1,050 525 15,000 750 1,125 563 1,575 788 20,000 1,000 1,500 750 2,100 1,050 25,000 1,250 1,875 938 2,625 1,313 30,000 1,500 2,250 1,125 3,150 1,575 35,000 1,750 2,625 1,313 3,675 1,838 40,000 2,000 3,000 1,500 4,200 2,100 45,000 2,250 3,375 1,688 4,725 2,363 50,000 2,500 3,750 1,675 5,250 2,625 55,000 2,750 4,125 2,063 5,775 2,888 60,000 3,000 4,500 2,250 6,300 3,150 65,000 3,250 4,875 2,438 6,825 3,413 70,000 3,500 5,250 2,625 7,350 3,675 75,000 3,750 5,625 2,813 7,875 3,938 80,000 4,000 6,000 3,000 8,400 4,200 85,000 4,250 6,375 3,188 8,925 4,463 90,000 4,500 6,750 3,375 9,450 4,725 95,000 4,750 7,125 3,563 9,975 4,988 100,000 5,000 7,500 3,750 10,500 5,250 105,000 5,250 7,875 3,938 11,025 5,513 110,000 5,500 8,250 4,125 11,550 5,775 115,000 5,750 8,625 4,313 12,075 6,038 120,000 6,000 9,000 4,500 12,600 6,300 125,000 6,250 9,375 4,688 13,125 6,563 130,000 6,500 9,750 4,875 13,650 6,825 135,000 6,750 10,125 5,063 14,175 7,088 140,000 7,000 10,500 5,250 14,700 7,350 145,000 7,250 10,875 5,438 15,225 7,613 150,000 7,500 11,250 5,625 15,750 7,875 155,000 7,750 11,625 5,813 16,275 8,138 160,000 8,000 12,000 6,000 16,800 8,400 165,000 8,250 12,375 6,188 17,325 8,663 170,000 8,500 12,750 6,375 17,850 8,925 175,000 8,750 13,125 6,563 18,375 9,188 180,000 9,000 13,500 6,750 18,900 9,450 185,000 9,250 13,875 6,938 19,425 9,713 190,000 9,500 14,250 7,125 19,950 9,975 195,000 9,750 14,625 7,313 20,475 10,238 200,000 10,000 15,000 7,500 21,000 10,500 205,000 10,250 15,375 7,688 22,525 10,783 210,000 10,500 15,750 7,875 22,050 11,025 215,000 10,750 16,125 8,063 22,575 11,288 220,000 11,000 16,500 8,250 23,100 11,550 225,000 11,250 16,875 8,438 23,625 11,813 230,000 11,500 17,250 8,625 24,150 12,075 t The 1994 date refers to dwellings constructed under the 1994 Minnesota Energy Code. The default KAIR used in this section of the table is 0.20 ACH. 2 This section of the table is to be used for dwellings constructed prior to 1994. The default KAIR used in this section of the table is 0.40 ACH. BURNSVILLE Heating & Air Conditioning, Inc. Table 501.4.1 Procedure to Determine Makeup Air Quantity for Exhaust Appliances in Dwelling Units ONE OR MULTIPLE POWER VENT OR DIRECT VENT APPLIANCES OR NO COMBUSTION APPLIANCESA ONE OR MULTIPLE FAN -ASSISTED APPLIANCES AND POWER VENT OR DIRECT VENT APPLIANCESB ONE ATMOSPHERICALLY VENTED GAS OR OIL APPLIANCE OR ONE SOLID FUEL APPLIANCEc MULTIPLE APPLIANCES THAT ARE ATMOSPHERICALLY VENTED GAS OR OIL APPLIANCES OR SOLID FUEL APPLIANCES!, 1. Use Appropriate Column to Estimate House Infiltration a) pressure factor (cfm/sf) 0.15 0.09 0.06 0.03 b) conditioned floor area (sf) 3620 (including unfinished basements) Estimated House 543 Infiltration (cfm): [lax 1b] 2. Exhaust Capacity a) Clothes dryer 135 135 135 135 b) 80% of largest exhaust rating (cfm) 64 (not applicable if recirculating system or if powered makeup air is electrica ly interlocked and matched to exhaust c) 80% of next largest exhaust rating (cfm): 64 (not applicable if recirculating system or if powered makeup air is electrica ly interlocked and matched to exhaust Total Exhaust Capacity (cfm): 263 [2a+2b+2c] 3. Makeup Air Requirement 547) Total Exhaust 263 Capacity (from above) b) Estimated 543 House Infiltration (from above) Makeup Air -280 Quality (cfm): [3a-3b] (if value is negative, no makeup air is needed 4. For Makeup Air opening Sizing, refer to Table 501.4.2 A. Use this column if there are other than fan -assisted or atmospherically venter gas or oil appliances or if there are no combustion appliances. B. Use this column if there is one fan -assisted appliance per venting system. Other atmospherically vented appliances may also be included. C. Use this column if there is one atmospherically vented (other than fan -assisted) gas or oil appliance per venting system or one solid fuel appliance. D. Use this column if there are multiple atmospherically vented gas or oil appliances using a common vent or if there are atmospherically vented gas or oil BURNSVILLE Heating & Air Conditioning, Inc. Table 501.4.2 Makeup Air Opening Sizing Table for New and Existing Dwelling Units TYPE OF OPENING OR SYSTEM ONE OR MULTIPLE POWER VENT OR DIRECT VENT APPLIANCES OR NO COMBUSTION APPLIANCESA ONE OR MULTIPLE FAN -ASSISTED APPLIANCES AND POWER VENT OR DIRECT VENT APPLIANCESB ONE ATMOSPHERICALLY VENTED GAS OR OIL APPLIANES OR ONE SOLID FUEL APPLIANCEc MULTIPLE APPLIANCES THAT ARE ATMOSPHERICALLY VENTED GAS OR OIL APPLIANCES OR SOLID FUEL APPLIANCESD PASSIVE MAKEUP AIR OPENING DUCT DIAMETERe,F,G (cfm) (cfm) (cfm) (cfm) (inches) Passive opening 1— 36 1— 22 1-15 1— 9 3 Passive opening 37 — 66 23 — 41 16 — 28 10 —17 4 Passive opening 67 —109 42 — 66 29 — 46 18 — 28 5 Passive opening 110 -163 67 —100 47 — 69 29 — 42 6 Passive opening 164 — 232 101-143 70 — 99 43 — 61 7 Passive opening 233 — 317 144 —195 100 —135 62 — 83 8 Passive opening w/motorized damper 318 — 419 196 — 258 136 —179 84 —110 9 Passive opening w/motorized damper 420 — 539 259 — 332 180 — 230 111-142 10 Passive opening w/motorized damper 540 — 679 333 — 419 231— 290 143 —179 11 Powered makeup airH >679 >419 >290 >179 NA A. Use this column if there are other than fan -assisted or atmospherically vented gas or oil appliances or if there are no combustion appliances. B. Use this column if there is one fan -assisted appliance per venting system. Other than atmospherically vented appliances may also be included. C. Use this column if there is on atmospherically vented (other than fan -assisted) gas or oil appliance per venting system or one solid fuel appliance. D. Use this column if there is multiple atmospherically vented gas or oil appliances using a common vent or I there are atmospherically vented gas or oil appliances and solid fuel appliances. E. An equivalent length of 100 feet of round smooth metal duct is assumed. Subtract 40 feet for the exterior hood and ten feet for each 90-degree elbow to determine the remaining length of straight duct allowable. F. If flexible duct is used, increase the duct diameter b one inch. Flexible duct shall be stretched with minimal sags. G. Barometric dampers are prohibited in passive makeup air openings when any atmospherically vented appliance is installed. H. Powered makeup air shall be electrically interlocked with the largest exhaust system. I , l'est 10„Heting C:: :'' '' ' — ,.7 TheaftSij, rib ' '' '445337•W;A-1-:;.. , _,..: , Trt - '`,y 1 Project Report Project Title: The San Fran Designed By: Alan Dobson Project Date: Friday, February 19, 2021 Project Comment: Client Name: Eternity Homes Company Name: Burnsville Heating & A/C Inc. Company Representative: Alan Dobson Company Address: 3451w Burnsville Pkwy, Suite 120 Company City: Burnsville,MN 55337 Company Phone: 952-894-0005 Company Fax: 952-894-0925 Company Comment: Reference City: Minneapolis, Minnesota Building Orientation: Front door faces South Daily Temperature Range: Medium Latitude: 44 Degrees Elevation: 834 ft. Altitude Factor: 0.970 Elevation Sensible Adj. Factor: 1.000 Elevation Total Adj. Factor: 1.000 Elevation Heating Adj. Factor: 1.000 Elevation Heating Adj. Factor: 1.000 Outdoor Outdoor Outdoor Indoor Indoor Grains Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference Winter: -15 -15.33 80% n/a 72 n/a Summer: 88 72 47% 50% 75 29 Total Building Supply CFM: 581 CFM Per Square ft.: 0.160 Square ft. of Room Area: 3,620 Square ft. Per Ton: 2,301 Volume (ifP) of Cond. Space: 33,656 Total Heating Required Including Ventilation Air: 45,399 Btuh 45.399 MBH Total Sensible Gain: 13,276 Btuh 70 % Total Latent Gain: 5,606 Btuh 30 % Total Cooling Required Including Ventilation Air: 18,881 Btuh 1.57 Tons (Based On Sensible + Latent) N:7010...;.(''. '''''' - V.,.,..,.- Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturees performance data at your design conditions. \\bhdata\RedirectedFolders ...\NJJ The San Fran 2021 SW.rhv Friday, February 19, 2021, 3:26 PM IF Rhvac r Re8. OP 18,139ht Commerciai HVAC Loads Elite SoftrvarR bevaiopmEIA It►� I Burr �ar�Ue Hating 8 JC inc r� t1ifShn Fran. r Bu%risvtlle; M1 55337 . Total Building Summary Loads y ^S i'-' "�" L;y� .+.„3'e^:r1 •4_ P$3w5 tr..-•1 $`u44I: iY"„t'. .a- a^ {"•'pu,'F -eJl�" ¢'L t`•41��- •• �}�+�'�'�'.-'Y"V'$ ' ,ek y�5\ "�.u✓.'+` '`wY,. �� "% 1. �: •5.... � WI .. ..f,�5::.'`.'s�b Wa .: T?Gs ..e,%� .�v i... 23, u-value 102.5 ,495 0 1,275 1,275 bah: Glazing -bah, ground reflectance = 0.2 0.28, SHGC 0.22 bah: Glazing -bah, ground reflectance = 0.23, u-value 93.5 2,278 0 1,035 1,035 0.28, SHGC 0.22 bah: Glazing -bah, ground reflectance = 0.23, u-value 25 587 0 201 201 0.27, SHGC 0.24 bah: Glazing -bah, ground reflectance = 0.23, u-value 42 987 0 330 330 0.27, SHGC 0.23 bah: Glazing -bah, ground reflectance = 0.23, u-value 11.6 263 0 221 221 0.26, SHGC 0.24 bah: Glazing -bah, ground reflectance = 0.23, u-value 42 987 0 330 330 0.27, SHGC 0.23 hbt: Door-hbt 20.4 266 0 73 73 hbt: Door-hbt 19 232 0 64 64 12F-0sw: Wall -Frame, R-21 insulation in 2 x 6 stud 2895.6 16,371 0 2,504 2,504 cavity, no board insulation, siding finish, wood studs 15B0-15sf-8: Wall -Basement, , R-15 board insulation to 800 2,923 0 0 0 floor, no interior finish, 8' floor depth R-49-ad: Roof/Ceiling-Under Attic with Insulation on Attic 1263.4 2,199 0 1,213 1,213 Floor (also use for Knee Walls and Partition Ceilings), Custom, R-49, dark asphalt 21A-20-v: Floor -Basement, Concrete slab, any thickness, 1200 2,819 0 0 0 2 or more feet below grade, no insulation below floor, vinyl covering, shortest side of floor slab is 20' wide Subtotals for structure: 32,407 0 7,246 7,246 People: 5 1,150 1,500 2,650 Equipment: 400 1,200 1,600 Lighting: 0 0 0 Ductwork: 4,613 348 2,187 2,535 Infiltration: Winter CFM: 19, Summer CFM: 0 1,783 0 0 0 Ventilation: Winter CFM: 192, Summer CFM: 192 6,596 3,708 879 4,587 AED Excursion: 0 0 264 264 Total Building Load Totals: 45,399 5,606 13,276 18,881 ,+ "z. Y, fit'„ u .c 's ki3 {(• 4 - w� `?"'r ..i.•9x{q: e 4, .-, t. s3. '-,: 'p�v5it {-+ Total Building Supply CFM: 581 CFM Per Square ft.: 0.160 Square ft. of Room Area: 3,620 Square ft. Per Ton: 2,301 Volume (ft3) of Cond. Space: 33,656 1000 gre-�ss�'.ex, snM.,r nx'�':xati... � ✓se- IT%3:�zk-'�':.,, �'.�;.;v,'i;as���.w::.'�.kv�, e. ,: a .r ...-v,.a"t' ..., ,: fit^`. .�:. �... Total Heating Required Including Ventilation Air: 45,399 Btuh 45.399 MBH Total Sensible Gain: 13,276 Btuh 70 % Total Latent Gain: 5,606 Btuh 30 % Total Cooling Required Including Ventilation Air. 18,881 Btuh 1.57 Tons (Based On Sensible + Latent) fi '-alMili»tT.t ;£ .A 4 ^'tieY i� �.F . A..:{ a.t? a:ve _m,� •F ,Ita:' .1'4�..�;f { •;`$'�'fl. _ ,'iti E.fG, y'xtF�'n `i -OWW Y,rty A '* Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. \\badata\RedirectedFolders ...\NJJ The San Fran 2021 SW.rhv Friday, February 19, 2021, 3:27 PM �f�vya�c���RasW{er�ttal,ght C�a�is(t3r/AC Loads Elite Saftwai�'Dpr�pr�` r Yl:;!oY�p��y!#"i7ryy�V /^ Burrs Ire;.liiNl�7 li <. ,.` s.s : ..s .... _ . z ; ....:.� . .. 'ft .. - ;.. _... .. .c� - .. , r -� ...Ya .X. r'+. 14- `System 1 Main Floor Summary Loads ��aeia�t`".� ' 3'' `3.. a d*P...., _ � ... .. � i����.Sr�+.rx bah: Glazing -bah, ground reflectance = 0.23, u-value 102.5 2,495 0 1,275 1,275 0.28, SHGC 0.22 bah: Glazing -bah, ground reflectance = 0.23, u-value 93.5 2,278 0 1,035 1,035 0.28, SHGC 0.22 bah: Glazing -bah, ground reflectance = 0.23, u-value 25 587 0 201 201 0.27, SHGC 0.24 bah: Glazing -bah, ground reflectance = 0.23, u-value 42 987 0 330 330 0.27, SHGC 0.23 bah: Glazing -bah, ground reflectance = 0.23, u-value 11.6 263 0 221 221 0.26, SHGC 0.24 bah: Glazing -bah, ground reflectance = 0.23, u-value 42 987 0 330 330 0.27, SHGC 0.23 hbt: Door-hbt 20.4 266 0 73 73 hbt: Door-hbt 19 232 0 64 64 12F-0sw: Wall -Frame, R-21 insulation in 2 x 6 stud 2895.6 16,371 0 2,504 2,504 cavity, no board insulation, siding finish, wood studs 15B0-15sf-8: Wall -Basement, , R-15 board insulation to 800 2,923 0 0 0 floor, no interior finish, 8' floor depth R-49-ad: Roof/Ceiling-Under Attic with Insulation on Attic 1263.4 2,199 0 1,213 1,213 Floor (also use for Knee Walls and Partition Ceilings), Custom, R-49, dark asphalt 21A-20-v: Floor -Basement, Concrete slab, any thickness, 1200 2,819 0 0 0 2 or more feet below grade, no insulation below floor, vinyl covering, shortest side of floor slab is 20' wide Subtotals for structure: 32,407 0 7,246 7,246 People: 5 1,150 1,500 2,650 Equipment: 400 1,200 1,600 Lighting: 0 0 0 Ductwork: 4,613 348 2,187 2,535 Infiltration: Winter CFM: 19, Summer CFM: 0 1,783 0 0 0 Ventilation: Winter CFM: 192, Summer CFM: 192 6,596 3,708 879 4,587 AED Excursion: 0 0 264 264 System 1 Main�yFloor Load Totals: 45,399 5,606 13,276 18,881 m :i: V ` ri''a` � y `e}`" 5-? �' 3�Cfi `P3' :'fi4Sf + .*✓' 2e Is YA` .f'. +u„ � �'' 34v1n. � '�`l6 '➢Y'`x^ °-P`,, 5 b .r . .. _ f. _.n.«.. .a,..'°',+r,.. ,-u .Si�`'?';.r>.d : � n°s:"aw'7�. t'.U.A. ? ^#,`y ','+�. •. fib`?��k' +.,sc, .'P., Y. ' � _ . ._ .'..a Supply CFM: 581 CFM Per Square ft.: 0.160 Square ft. of Room Area: 3,620 Square ft. Per Ton: 2,301 Volume (ft') of Cond. Space: 33,656 'e,}}�� Y✓.�',"§t' -�'3 z. 'x'4 .s< jFv,, .u+5:. Total Heating Required Including Ventilation Air: 45,399 Btuh 45.399 MBH Total Sensible Gain: 13,276 Btuh 70 % Total Latent Gain: 5,606 Btuh 30 % Total Cooling Required Including Ventilation Air: 18,881 Btuh 1.57 Tons (Based On Sensible + Latent) Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. \\badata\RedirectedFolders ...\NJJ The San Fran 2021 SW.rhv Friday, February 19, 2021, 3:27 PM City Inspection Dept. Copy City Forester Copy Applicant/Builder Copy ?6,c-g INDIVIDUAL RESIDENTIAL LOT TREE PRESERVATION PLAN SUMMARY CITY OF EAGAN FORESTRY DIVISION 651-675-5300 (BUILDER, PLEASE READ ATTACHMENTS) Development Summerbrooke Lot Number 9 Block Number 1 Address 787 Summerbrooke Court Builder Eternity Homes Phone Number: 651-460-3043 Contact: Ann Hamman Tree Protection Requirements: Replacement Trees: Attachments: Tree Protection Fencing to be Installed on Site (Orange Poly Fence) Oak Tree Pruning (Immediately seal wounds during April 1 to July 31) Therapeutic Pruning Required Retaining Wall To Be Installed Other: Not Required: As Follows: X Yes (Refer to attached docwmonts for detail No Additional Notes: EAGAN FORESTRY DIVISION REVIEWED BY 14-cr►)._thei_c- (liAr DATE V7-4 4-1 ADDRESS: 787 SUMMERBROOKE COURT 0 932.255 x 933.0 932.455 9323 .9 r 933.E } 71.415 PvT .5 -1 L_V I I I N87°39'58' W 68.28 CERTIFICATE OF SURVEY FOR ETERNITY HOMES POND T0876 Ate IIWL-909.5 RIM.914.51 915.3 '!1915.b DRMNAGC 4 UTIIMf o x1915.1 - cA3D83 T SI:iBRCKTTNe x 923.3 allg x 923.6 EOSOING RETAINING WALL LOT 9 BLOCK 1 z 925.3 } x 9253 926. ex•R, YY0T21111- 'lira .7 927.1 931.4 200 926.2 12.3 x 927.9 PROPOSED 2-STORY FB/WO z93j2 } I 32.78 3I O PORCH 20.0 CARE 932.9 TOP 931./ 611.9 932.2 931.9 .0 �Ih SS } 4i1"‘ 19.50 I} } 927.6 j 6.0 931.8 9271 9 f z 932.1 GARAGE 14.0 933.0x PROPOSED DRIVEWAY 4.1% 4.0 932.4 1 9223 N co 932.4 6Ax } 31 x9319 311 99 x 93]1 931.E 93h N89°41 9313 x 9313 40' W 73.36 9313 911.2 } } } MTD r gS CONCRETE CURE 4 GUTTER 9323 SUMMERBROOKE COURT DENOTES MAILBOX DENOTES IRON PIPE MONUMENT SET • DENOTES FOUND IRON PIPE MONUMENT �-- DENOTES PROPOSED DRAINAGE DIRECTION ▪ DENOTES SERVICE LOCATION A7 DENOTES WOOD HUB 000.0 DENOTES EXISTING ELEVATION ® DENOTES PROPOSED ELEVATION DENOTES EXISTING CONTOUR DENOTES DECIDUOUS TREE 411* DENOTES EVERGREEN TREE DENOTES BITUMINOUS SURFACE DENOTES CONCRETE SURFACE DENOTES GRAVEL SURFACE CD7TERUNE SETBACKS FRONT-30' SIDE ALONG RIGHT OF WAY = 30' SIDE INTERIOR - 10' ON R-1 (R-1 Is lots over 12,000 so SIDE INTERIOR ON R1-S = 6' SIDE ON GARAGE = 5' REAR - 15' NOTE: ANY LIVING SPACE IS CONSIDERED THE HOUSE SETBACK, NOT THE GARAGE SETBACK Bohlen Surveying & Associates 31432 Fano Avenue NONMIe16, MN 66067 Phone:(507) 845.7788 ta7wn4)0°h1wurwong.c°m B A 1682 CM R°ed BumMM, MN 65337 Phone:(952) 8964212 Fox. (962) 6954259 NOTE' ALL BUILDING DIMENSIONS ARE SHOWN TO OUTSIDE OF FOUNDATION WALL BENCH -MARK FIRE HYDRANT AT END OP SUMMERBROOKE CIRCLE, TNH ELEV. = 915.99 LOT AREA - 10,175 SO. FT. HOUSE AREA - 1,917 SO. FT. PORCH AREA = 120 So. FT SIDEWALK - 155 SO. FT. DRIVEWAY = 814 SO. FT IMPERVIOUS = 3,006 S0. FT = 29.5X 1"=20' PROPOSED TOP OF WALL ELEV. - 934.2 PROPOSED GARAGE FLOOR ELEV.. - 933.9 PROPOSED BASEMENT FLOOR ELEV. - 926.5 PROPERTY DESCRIPTION LOT 9, BLOCK 1, SUMMERBROOKE, CITY OF EAGAN, DAKOTA COUNTY, MINNESOTA. I HEREBY CERTIFY THAT THIS SURVEY WAS PREPARED BY ME OR UNDER MY DIRECT SUPERVISION AND THAT I AM A DULY LICENSED LAND SURVEYOR UNDER THE LAWS OF THE STATE OF MINNESOTA. DATE: 1-26-2021 1 IIOI'Wd a 'Ltdld THOMAS J. O'MEARA, LAND SURVEYOR MINNESOTA LICENSE NO. 48187 S:1Projects\Eo on oummerbxooke\dwgl5o29blk1-CERT.dwg 1/25/2021 10:14:07 AM CST TREE PRESERVATION PLAN REVIEW — INDIVIDUAL LOT EAGAN Date Building Permit Application Received Development Summerbrooke Site Address 787 Summerbrooke Ct 2/24/2021 Lot 9 Block 1 Builder Eternity Homes Telephone (651)-460-3043 Property/Lot Owner Name - Telephone - Contact Ann Hamman E-mail drafting@eternityhomesllc.com E-mail - Office Plan Review — Date 2/26/2021 Notes Mitigation in lieu of planting has been accepted by the city. Therefore, no additional mitigation is required. Planting of front yard trees is optional and encouraged but, not required. Tree Preservation Data Original Plan Revised Plan Total Significant Woodland Area sq. ft sq. ft Total Significant Trees Woodland To Be Removed sq. ft sq. ft Trees To Be Removed Allowable Woodland Removal (20%) sq. ft sq. ft Allowable Tree Removal (20%) Required Mitigation YES (or) NO Calculated Mitigation Amounts Original Plan - Category A Category B Category C Revised Plan - Category A Category B Category C Site Inspection — Date 2/26/2021 Notes Four (4) Black Hills Spruce were installed in BY area, summer of 2018. No other trees present. Home Location staked. Previously planted trees must be protected through the installation of tree protection fencing prior to construction. Contact City Forester to schedule an inspection. G:\Forestry\TreePreservation\Tree Preservation Plan Review - Individual Lot.docx Original Tree Preservation Plan Approved — Date 11/21/2018 By Forwarded to Inspections — Date 2/26/2021 By Discussion/Meetings with Builder/Owner - Notes Revised Tree Preservation Plan Approved — Date By Forwarded to Inspections — Date By Additional Field Inspections Date Notes Date Notes Date Notes Date Notes G:\Forestry\TreePreservation\Tree Preservation Plan Review - Individual Lot.docx 787 Summerbrooke Ct z� "la ° \ {\ C ;f \ eL _ £ Address Labels Aerial Street Names Four (4) Spruce Installed 2018 _RegtUired PLANTING SCHEDU KEY COMMON NAME/SCIENTIFIC NAME ROOT OVERSTORY TREES 0. AUTUMN BLAZE MAPLE/ACER X FREEMANII 4" B&B 0 HACKBERRY/CELT1S OCCIDENTAUS 4" B&B vL ' SENTRY LINDEN/11LIA AMERICANA 'SENTRY 4" B&B 11'" RED OAK/QUERCUS RUBRA 4" B&B ✓ ���, RIVER BIRCH/BETULA NIGRA 12' B&B `} SWAMP WHITE OAK/QUERCUS BICOLOR 4' B&8 EVERGREEN TREES a WHITE PINE/PINUS STROBUS 12' B&B BLACK HILLS SPRUCE/PICEA GLAUCA DENSATA 12' B&B O z ❑✓ ❑ ❑✓ ❑ ❑✓ ❑ ❑ El ❑✓ ❑ ❑✓ ❑ ✓❑ ❑ ✓❑ ❑ ❑✓ ❑ ❑� ❑ ❑✓ ❑ 0 ❑ ❑❑❑❑❑❑❑❑❑❑❑❑ Add/Change PROPERTY LEGAL: /7C LOT SURVEY CHECKLIST FOR RESIDENTIAL BUILDING PERMIT APPLICATION Lot 9, Block 1, Summerbrooke DATE OF SURVEY: 1/26/21 ' LATEST REVISION: DOCUMENT STANDARDS • Registered Land Surveyor signature and company • Building Permit Applicant • Legal description • Address • North arrow and scale • House type (rambler, walkout, split w/o, split entry, lookout, etc.) • Directional drainage arrows with slope/gradient % • Proposed/existing sewer and water services & invert elevation • Street name • Driveway (grade & width - in R/W and back of curb, 22' max.) • Lot Square Footage • Lot Coverage ELEVATIONS Existing ❑✓ ❑ ❑ • Property corners ❑✓ ❑ El • Top of curb at the driveway and property line extensions ❑✓ ❑ ❑ • Elevations of any existing adjacent homes ❑✓ ❑ ❑ • Adequate footing depth of structures due to adjacent utility trenches ❑✓ 0 0 • Waterways (pond, stream, etc.) • Proposed El El ❑ • Garage floor El 0 0 • Basement floor El 0 ❑ • Lowest exposed elevation (walkout/window) ❑✓ 0 ❑ • Property corners El 0 ❑ • Front and rear of home at the foundation iQ • PRV Required ❑ El ❑ a❑❑ a❑❑ ❑ o❑ ❑ 0 ❑ ❑ El ❑ No Q INTITM PONDING AREA (if applicable) • Easement line • NWL • HWL • Pond # designation • Emergency Overflow Elevation • Pond/Wetland buffer delineation • Shoreland Zoning Overlay District • Conservation Easements DIMENSIONS ❑✓ ❑ ❑ • Lot lines/Bearings & dimensions ✓❑ ❑ El • Right-of-way and street width (to back of curb) ❑✓ ❑ 0 • Proposed home dimensions including any proposed decks, overhangs greater than 2', porches, etc. (i.e. all structures requiring permanent footings) ❑✓ ❑ ❑ • Show all easements of record and any City utilities within those easements ❑✓ ❑ ❑ • Setbacks of proposed structure and sideyard setback of adjacent existing structures ,r❑ ❑ ❑ • Retaining wall requirements: Reviewed By: Dave Westermayer Date 2/24/21 G:/1 Engineering/Forms/Cert. of Survey Checklist Fillable 6-28-19 ADDRESS: 787 SUMMERBROOKE COURT 3:1 M" imurn Slcpe3 cr Wait Will INSTALL PERIMETER 922.8 L J r - I-- C) - J 932.2 917.6 922.6 x 924.3 0) x 933.0 II 932.4x 932.5x I x 921.3 5 f I x 93-.2 f 11 x 932.5 931.9 x x 932.2 931.8 I 0 • 917.1 /7� CERTIFICATE OF SURVEY FOR ETERNITY HOMES I C11- 4 .I L-L/ I I I N87°39'58"W 68.28 0 x 916.5 x 915.8 DRAINAGE 4 UTILITY 918.5 ,,,6.9 EASEMENT 916.5 92a.4 0 921.9 923.E 922.0 922.0 ;" SETBACK LINE ! 92d 1 x 923.5 J EXISTING RETAINING WALL x 923.6 LOT 9 BLOCK 1 x 925.3 x 925.5 926.42'-CANTILEVER gryb. O 12.0 O ( b? '� v 2' CANTILEMER(q`\' 5.7 927.1 926.2 12.3 931.4 20.0 x 927.9 PROPOSED 927.6 ^ G.0 2-STORY a FB/WO R PORCH D 20.0 ( 'n r .-..981.9 0 GARAGE I � N I i 0 32.78 CEO) x 932.9 CURB 932.9„ STOP x 932.5 N89°41 932.3 932.2 30.0 (.0 I 933.0x PROPOSED DRIVEWAY m 4. 1 % Om x 932.3 40"W 73.36 - 22.0 } 931,_8 x 932.1 O 923.5 wE ,z' <I tr), 19.50 927.2 931.6 4.0 v N 932.4 /j 916 STORM MANHOLE RIM=9 14.5 I 07. ls.o x 915.4 6 w• 921.9 Nx ass t 922.5 POND h WL= 909.5 () 1■II N � 1 x x923.8 N ° f q26 6 9.50 03 N V CV x 6 • W O CV Co 0 Z x 932.4 x 932.8 932.3 932.2 CONCRETE CURB d GUTTER 932.3 SUMMERBROOKE COURT CENTERLINE ® DENOTES MAILBOX O DENOTES IRON PIPE MONUMENT SET • DENOTES FOUND IRON PIPE MONUMENT DENOTES PROPOSED DRAINAGE DIRECTION 0 000.0 (000.o) '0oo_ DENOTES SERVICE LOCATION DENOTES WOOD HUB DENOTES EXISTING ELEVATION DENOTES PROPOSED ELEVATION DENOTES EXISTING CONTOUR DENOTES DECIDUOUS TREE DENOTES EVERGREEN TREE DENOTES BITUMINOUS SURFACE DENOTES CONCRETE SURFACE DENOTES GRAVEL SURFACE 93x1.8 EXISTING DOUSE (933.4) - 22.0 SETBACKS FRONT-30' SIDE -ALONG RIGHT OF WAY = 30' SIDE INTERIOR = 10' ON R-1 (R-1 is lots over 12,000 sf) SIDE INTERIOR ON R 1-S = 6' SIDE ON GARAGE = 5' REAR = 15' NOTE: ANY LIVING SPACE IS CONSIDERED THE HOUSE SETBACK, NOT THE GARAGE SETBACK Bohlen Surveying & Associates 31432 Foliage Avenue Northfield, MN 55057 Phone: (507) 645-7768 tomeara@bohlensurveying.com B A NOTE: ALL BUILDING DIMENSIONS ARE SHOWN TO OUTSIDE OF FOUNDATION WALL BENCH -MARK FIRE HYDRANT AT END OF SUMMERBROOKE CIRCLE, TNH ELEV. = 915.99 LOT AREA = HOUSE AREA = PORCH AREA = SIDEWALK = DRIVEWAY = IMPERVIOUS = 10,175 SQ. FT. 1,917 SQ. FT. 120 SQ. FT. 155 SQ. FT. 814 SQ. FT 3,006 SQ. FT = 29.5% 1"=20' LAUAN t,NCaOIL cll\ia L;sa fi I. PROPOSED TOP OF WALL ELEV. = 934.2 PROPOSED GARAGE FLOOR ELEV. = 933.9 PROPOSED BASEMENT FLOOR ELEV. = 926.5 PROPERTY DESCRIPTION LOT 9, BLOCK 1, SUMMERBROOKE, CITY OF EAGAN, DAKOTA COUNTY, MINNESOTA. I HEREBY CERTIFY THAT THIS SURVEY WAS PREPARED BY ME OR UNDER MY DIRECT SUPERVISION AND THAT I AM A DULY LICENSED LAND SURVEYOR UNDER THE LAWS OF THE STATE OF MINNESOTA. 1682 Cliff Road E. Burnsville, MN 55337 DATE: 1-26-2021 Phone: (952) 895-9212 Fax: (952) 895-9259 Thor/ I Clean& THOMAS J. O'MEARA, LAND SURVEYOR MINNESOTA LICENSE NO. 46167 S:\Projects\Eagan\summerbrooke\dwg\1ot9b1k1-CERT.dwg 1/25/2021 10:14:07 AM CST PERMIT City of Eagan Permit Type:Building Permit Number:EA171276 Date Issued:08/09/2021 Permit Category:ePermit Site Address: 787 Summerbrooke Ct Lot:9 Block: 1 Addition: Summerbrooke PID:10-72950-01-090 Use: Description: Sub Type:Fireplace Work Type:Gas Fireplace (new) Description: Census Code:434 - Residential Additions, Alterations Zoning: Square Feet:0 Occupancy: Construction Type: Comments:Improvements to the home may require smoke detectors in all bedrooms. Chimney / flue must be inspected prior to concealing. Carbon monoxide detectors are required within 10 feet of all sleeping room openings in residential homes (Minnesota State Valuation: 3,000.00 Fee Summary:BL - Base Fee $3K $88.50 0801.4085 Surcharge - Based on Valuation $3K $1.50 9001.2195 $90.00 Total: I hereby acknowledge that I have read this application and state that the information is correct and agree to comply with all applicable State of Minnesota Statutes and City of Eagan Ordinances. Contractor:Owner:- Applicant - Hans D & Danielle Kaardal Meyer 5200 46th Ave S Minneapolis MN 55417 Glowing Hearth And Home Llc 100 Eldorado Dr. Jordan MN 55352 (952) 492-9276 Applicant/Permitee: Signature Issued By: Signature