Loading...
1446 Dolores Lane - Energy Code Compliance Certificate 2021-03-31 New Construction Energy Code Compliance Certificate Per N1101.8 Building Certificate. A building certificate shall be posted in a permanently visible location inside Date Certificate Posted the building. The certificate shall be completed by the builder and shall list information and values of components listed in Table N1101.8. Mailing Address of the Dwelling or Dwelling UnitCity 1446 Dolores LaneEagan Name of Residential Contractor MN License Number Caritas Builders, Inc. BC692398 THERMAL ENVELOPERADON SYSTEM Type: Check All That Apply Passive (No Fan) Active (With fan and monometer or other system monitoring device) Insulation Location Other Please Describe Here Total R-Value of all Types of InsulationNon or Not ApplicableFiberglass, BlownFiberglass, BattsFoam, Closed CellFoam Open CellMineral FiberboardRigid, Extruded PolystyreneRigid, Isocynurate 10x Below Entire Slab Foundation Wall 10x Perimeter of Slab on Grade interior R10 20x Rim Joist (Foundation) interior st 20x Rim Joist (1 Floor+) interior 20x Wall 49x Ceiling, flat 49x Ceiling, vaulted n/a Bay Windows or cantilevered areas n/a Bonus room over garage Describe other insulated areas Windows & Doors Room by Room U factor & SHGC for Windows Heating or Cooling Ducts Outside Conditioned Spaces Unigue to Room Average U-Factor (excludes skylights and one door) U: Not applicable, all ducts located in conditioned space Solar Heat Gain Coefficient (SHGC):Unigue to RoomR-value Select a Type MECHANICAL SYSTEMS Slab on Grade: Furnace & AC heat & cool 1st & 2nd Levels Make-up Air Heating System Domestic Water Heater Cooling SystemXNot required per mech. code Appliances Natural GasNatural GasElectric Fuel Type Passive LennoxNavienLennox Manufacturer Powered Interlocked with exhaust device. NCB-240-130H13ACXN-030 Model ML193UH070XE36B Describe: Input in Capacity in On Demand Output in 660002.5Other, describe: BTUS:Gallons:Tons: Rating or Size Heat Loss: Heat 4327224161 Location of duct or system: Gain: Structure's Calculated AFUE or SEER: 9313 HSPF% Calculated 28717 Cfm's Efficiency cooling load: " round duct OR " metal duct Mechanical Ventilation System Select a Type Combustion Air Describe any additional or combined heating or cooling systems if installed: (e.g. two furnaces or air XNot required per mech. code source heat pump with gas back-up furnace): Navien Combi-boiler for domestic & In-Floor (toe warmer) Passive Select Type Other, describe: Heat Recover Ventilator (HRV) Capacity in cfms:Low: 68High:135 Location of duct or system: Energy Recover Ventilator (ERV) Capacity in cfms:Low: High: Continuous exhausting fan(s) rated capacity in cfms: Cfm's Location of fan(s), describe: IN HRV & BATHROOMS 68 " round duct OR Capacity continuous ventilation rate in cfms: " metal duct Total ventilation (intermittent + continuous) rate in cfms:548 Created by BAM version 052009