4002 Havens Wood Ct61,- I--o0 I o —4j2, Ioc,510
o I � , � 0 0, 0 r For Office UseEAGAN 1
1
0d2C — 1 o o , Od Permit #: 7 0 0 f
12,30`."
3830 PILOT KNOB ROAD I EAGAN, MN 55122-1810
(651) 675-5675 I TDD: (651) 454-8535 i FAX: (651) 675-5694 APR 2 2 2021
buildinginspectionsCo?citvofeagan.com S zIA) I qo 02]
2020 RESIDENTIAL BUILDING PERMIT APPLICATION
Date: 4-20-2021 Site Address: 4002 Haven Woods Court unit #:
SD Companies LLC Phone: 651-994-3997
Permit Fe7e: 12'1 3 t ' ,S b
Date Received:
Type of Work.
Name:
Address / City / zip: 750 Main Street Suite 223, Mendota Hghts MN 55118
Applicant is: � Owner Contractor
Description of work: N e W Home
Construction Cost: 750,000'00 Multi -Family Building: (Yes / No )
Company:
SD Custom Homes contact: Sean Doyle
Address:
750 Main Street Suite 223 City: Mendota Heights
State: MN Zip: 55118 Phone: 651-994-3997 Email: sean@sd-customhomes.com
Staff
J
License #: BC637953 Lead Certificate #:
If the project is exempt from lead certification, please explain why:
COMPLETE THIS AREA ONLY IF CONSTRUCTING A NEW BUILDING
In the last 12 months, has the City of Eagan issued a permit for a similar plan based on a master plan?
Yes No If yes, date and address of master plan:
Licensed Plumber: Servin Plumbing Phone:
Mechanical Contractor: Lofgren Heating and Air Conditioning Phone:
Sewer &water contractor:
Jerry Voehl Phone: 612-819-8267
Fire Suppression Contractor: N/A Phone: �w
NOTE: Plansandsupporting documents that you submit are considered to be public information. Portions of the information may be
classified as non • ubhc if ou rovide s • ecific reasons that would • ermit the Cit to conclude that they are trade secrets.
You may subscribe to receive an electronic notification from the City of proposed ordinances by signing up for an email update on the City's
website at www.citvofeaaan.com/subscribe.
Exterior work authorized by a building permit issued in accordance with the Minnesota State Building Code must be completed within 180
days of permit issuance.
CALL BEFORE YOU DIG. Call Gopher State One Call at (651) 454-0002 for protection against underground utility damage. Call 48 hours before you
intend to dig to receive locates of underground utilities. www.gopherstateonecall.orq
hereby acknowledge that this information is complete and accurate; that the work will be in conformance with the ordinances and codes of the City of
Eagan; that I understand this is not a permit, but only an application for a permit, and work is not to start without a permit; that the work will be in
accordance with the approved plan in the case of work which requires a review and approval of plans. Digitally signed by Sean Doyle
X Sean Doyle XSe� QDate 2021.04.20131151 -05'00,
Applicant's Printed Name Applicant's Signatu
DO NOT WRITE BELOW THIS LINE
SUB TYPES
Foundation
Single Family
Multi
01 of _ Plex
WORK TYPES
New
Addition
Alteration
Replace
Retaining Wall
DESCRIPTION
Valuation
Plan Review
(25%_ 100% \)
Census Code
# of Units
# of Buildings
Type of Construction
Fireplace
Garage
Deck
Lower Level
Interior Improvement
Move Building
Fire Repair
Repair
REQUIRED INSPECTIONS
A, Footings (New Building)
x Footings (Deck)
Footings (Addition)
Foundation y Foundation Before Backfill
Roof: Ice & Water Final
Framing 30 Minutes 1 Hour
Fireplace: "Rough In Air Test Fin<
Insulation
Sheathing
Sheetrock
Fire Walls
Braced Walls
Shower Pan
Porch (3-Season)
Porch (4-Season)
Porch (Screen/Gazebo/pergola) _
Pool
Occupancy
Code Edition
Zoning
Stories
Square Feet
Length
Width
Siding
Reroof
Windows
Exterior Alteration (Single Family)
Exterior Alteration (Multi)
Miscellaneous
Accessory Building
Demolish Building*
Demolish Interior
Demolish Foundation
Egress Window Water Damage
*Demolition of entire building — give PCA handout to applicant
MCES System
G2 SAC Units
City Water
Booster Pump
PRV
Fire Suppression Required
Meter Size:
Final / C.O. Required
Final / No C.O. Required
HVAC Service Test
Pool: __Footings Air/Gas Tests Final
Drain Tile
Siding: _Stucco Lath
Windows
Retaining Wall:
Radon Control
Fire Suppression: _Rough In Final
Erosion Control
Other:
Gas Line Air Test Hood
_ Brick EFIS
Footings Backfill Final
Reviewed By: , Building Inspector
RESIDENTIAL FEES
Base Fee
Surcharge
Plan Review
MCES SAC
City SAC
Utility Connection Charge
S&W Permit & Surcharge
Treatment Plant
Radio Meter Read
Copies
TOTAL
31 q79,1,41/14131
7�
�.l
r1hrRo ' - V'V y/- 3&', /7+1,3�.
�y " t0 n�
5 Atw vZ '511: (),/
floniAk
Si'2i �g�)
,l'Jof V�
1/9t h 2--1 ,/ y 10
i //3 ytir.23._.
EAGAN
STORMWATER MANAGEMENT PLAN
REQUIREMENTS
1. Land Disturbance (grading) Plan ($4.34.E.a)
• Delineation of subject property and all public and private easements,
• Delineation of area(s) to be graded or excavated,
• Annotate location of existing and proposed buildings and impervious surfaces including quantities (sqft).
• Identification of all significant natural features including wetland buffer zones, buffer setbacks, significant trees, steep
slopes (3:1 slope or greater) within the property and waterbodies, stormwater conveyance or treatment features, or any
other unique or sensitive natural features within 100ft of the property's boundaries.
• Identification of onsite drainage patterns using drainage arrows.
• Identification of existing and proposed grading using a maximum of 2ft intervals within the property,
• The location and size of all existing and proposed sanitary sewer, storm sewer, or other utility services.
2. Storm Water Pollution Prevention Plan (SWPPP) ($4.34.E.b)
• Delineation of limits of land -disturbing activities and construction.
• Location and types of temporary erosion and sediment control devices including but not limited to sediment control
perimeter devices, erosion control devices, storm drain inlet protection, rock construction entrances, dust control, tree
protective fencing and other pollution prevention requirements set forth in city code §4.34 and MPCA's Construction
Stormwater Permit if the project has an acre or greater of land disturbance.
• Location and types of permanent erosion control devices, including plant & seed list.
• Location of dirt or soil storage and other building material stockpile areas.
• Provide name and contact information of individuals(s) responsible to manage pollution prevention practices.
• Description of inspection schedule to be completed by the responsible party:
o Every 7-days of exposed soil areas,
o Within 24-hours of a'/2 inch rain event,
o Every 30-days of areas that are stabilized but construction activity continues
o Prior to resuming construction following an extended pause in activity
• Description of an erosion and sediment control maintenance schedule by the responsible party:
o Within 24-hours, remove any sediment build-up on perimeter control devices exceeding 1/3 of the device height
or storage capacity.
o Within 24-hours maintain or replace any non-functioning pollution prevention devices or practices.
o Within 24-hours remove any deposited sediment, debris, or trash from adjacent properties, streets, or sidewalks
following discovery.
o Within 14-days after land disturbing activities have ceased, temporarily or permanently stabilize exposed soils.
Permit Termination Conditions
• If land disturbance is an acre or greater, the permittee must establish permanent vegetative coverage of all impacted
area excluding paved areas or areas covered by permanent structures. Vegetative coverage must consist of a uniform
perennial vegetation with a density of 80% of the expected final growth. In addition, all temporary pollution prevention
devices must be removed, and any remediation or restoration efforts must be completed prior to final inspection and
release of financial securities.
• If land disturbance is Tess than an acre, the permittee must establish temporary erosion control coverage of all
impacted area excluding paved areas or areas covered by permanent structures. MPCA and MnDOT specifications
must be met dependent of the erosion control product used including application of temporary grass seed at an
approved rate. In addition, adequate perimeter control devices must be installed downstream and any remediation or
restoration efforts must be completed prior to a final inspection and release of financial securities.
• All projects, If a permanent stormwater treatment/ volume retention facility was required, the facilities must be
inspected by Water Resource staff and must be determined to be in compliance with proposed specifications and all
requirements identified in §4.34.F through §4.34.l are met prior to final inspection and the release of stormwater
performance securities.
3830 PILOT KNOB ROAD EAGAN, MN 55122
(651) 675-5300 I waterres@cityofeagan.com
If you have a hearing or speech disability, contact us through your preferred telecommunications relay service.
1).7 j J (Op 7
j A E ?= A m A
��ooQ0(Do
6 N n N?
% N m N P,2 m
3 o m
N
X N N . 'a
O 7cp
(O/) O. N 7 ° O
(U 0. N
N p N "00
4.s a0 m .0
N (7 N (n. N N B
oda om�7
�(0
c'
C
W *. o O O
7 C N 0
< r
N(p a O (O R
n O. (D 'p
D N Q = D N
N (O
w
O g§4o
3 N
j
d o 0
3
O
•
z
0
m
2
1l
m
m
H
D r
00
Z N
co
z r
Z O
rt 0
7
0
0
O
0
O
S400M N3,WH
a
m
O F
0
5
N
v
m 3
z
m
z
z
m
0
0
C
r
z
T�
0
m
z
^ci)
l J
2
m
C
r
m
m
0
z
D
z
0
m
0
m
z
O
z
H
0
m
0
z
z
//0
VJ
m
0
m
z
0
0
O
I
z
0
4(9
1N3QIS32I 0
oos`1—InN3W3S ��1�bM
b8 .t
�.868 th
SOS ad,......,._&�_,
i
3ON33 11IS
03SOdO221d
3ONV211N3 XO021
0Vd ONI01If18
0
0
m
0
P1
D
m
CT.
S2JflO1N00 03SOd02ld
NVId 2J3d NOI1VA313
m
r
7J
A
0
0
X
y
X08 3NOHd3131
0
0
0
C
A
0
0
P1
ri
N
0
cn
m
0
0
TI /
M01.d2J3A0 AON30d3W3
0
C
co
0
0
0
t3
0
Z
13S 1N3Wf1NOW
N01103L110
0
0
>
z
D
0
m
03NOISSV ION
>0
ors)
no
00
00
C-
Z
K
Z Z
w 0
ov
w
0
0
U)
:NOIldILIOS341V031
0
V) III
0
I -9
n (3
C D
C/) ni
—I O
O
()
= C
O m
rn -n
(/) O
w
O
NOIIVA313 03SOd02id
:aN3931 3dVDSONV1
X
w
0
o m
z
0
NOIIVA313 ONIISIX3
Z
m
m
0
0
0
0
Sd00M N3AVH
• • •
0 0'
0
D
0
m
z
z
/m^
VJ
m
0
r
m
:31f1a3HOS N0103dSNI
m
Q
z
z
/0
VJ
m
0
m
z
0
z
0
301i1NOO 1N3WIa3S ONV NOISOI:13
O
I
z
0
rn
f-`
l N301S
3a Z#
oos 1N3w3S ��1lbM
Sop H�
`~9Rn
ti
30N3d l�IS
30NV81N3 Ai008 03SOd08d
DS CT.
J
0Vd ONIOhll8
m
0
m
0
D
m
Sbl01N00 03SOd08d
NOIIVA313
NV1d ?J3d
0
-1
o o c f 0 O
X08
m N
v
0
N
(n
0
m
TI
r
0
0
MO1d83A0 AON3083W3
dO1S 8bl0
0
Z
13S 1N31/IfNOW
AO N01103810
0
D
z
D
0
m
03NOISSV ION
>0
0 N
D W
00
0
C
Z
� G
zz
m c�
oa
co
0)
0
NOI1VA313 03SOd08d
0
0
77
m
:NOIldIHOS3G 1V031
:aN30313dVOSONV1
X
w m
m
z
0
NOIIVA313 ONIISIX3
New Construction Energy Code Compliance Certificate
Per R401.3 Certificate. A building certificate shall be posted on or in the electrical distribution
panel.
Date Cert. Posted
Mailing Address of the Dwelling or Dwelling Unit
4002 Haven Woods Ct
City
Eagan
Name of Residential Contractor
SD Custom Homes
MN License
BC637953
Number
THERMAL ENVELOPE
RADON
CONTROL SYSTEM
Insulation Location
Total R-Value of all Types of
Insulation
Type:
Check
All That Apply
✓
Passive (No Fan)
Non or Not Applicable
Fiberglass, Blown
Fiberglass, Batts
Foam, Closed Cell
Foam Open Cell
Mineral Fiberboard
Rigid, Extruded Polystyrene
Rigid, Isocynurate
Active fan
(With and monitoring
device)
Location
(or future location) of Fan:
Attic
Other
Please Describe Here
Below Entire Slab
X
Foundation Wall
R-10
X
Perimeter of Slab on Grade
X
Rim Joist (1st Floor)
R-20
X
Rim Joist (2nd Floor+)
R-20
X'
Wall
R-20
X
Ceiling, flat
R-50
X
Ceiling, vaulted
R-50
X
X-
Bay Windows or cantilevered areas
R-30
X
Floors over unconditioned area
R-30
X
Describe other insulated areas
Building envelope air tightness:
Duct
system
air tightness:
Windows & Doors
Heating
or
Cooling Ducts Outside
Conditioned Spaces
Average U-Factor (excludes skylights and one door) U:
.30
./
Not
applicable, all ducts
located in conditioned space
Solar Heat Gain Coefficient (SHGC):
.28
R-value
MECHANICAL SYSTEMS
Make
up Air Selecta Type
Appliances
Heating System
Domestic Water
Heater
Cooling
System
X
Not required per mech. code
Fuel Type
Natural Gas
Natural Gas
Electric
Passive
Manufacturer
Carrier
Carrier
Powered
Model
Interlocked with exhaust device.
Describe:
Rating or Size
Input in
BTUS:
80,000
Capacity in
Gallons:
Output
in Tons:
3 1/2
Other, describe:
Efficiency
AFUE or
HSPF%
95
SEER
/EER
13
Location
of duct or system:
Residential Load
Calculation
Heating Loss
Heating Gain
Cooling Load
69.322
34.781
3.46
Cfm's
" round duct OR
MECHANICAL VENTILATION SYSTEM
" metal duct
Describe any additional or combined heating or cooling systems if installed: (e.g. two furnaces or air
source heat pump with gas back-up furnace): ERV RUN ON TIMER AT 50%
Select Type
Combustion
Air Select a Type
Not required per mech. code
x
Passive
Heat Recover Ventilator (HRV) Capacity in cfms:
Low:
High:
Other, describe:
Energy Recover Ventilator (ERV) Capacity in cfms:
Low:
High:
240
Location of duct or system:
MECH ROOM
Balanced Ventilation capacity in cfms:
Location of fan(s), describe: Bathroom, Hood Fan, Kitchen, Laundry Room
Cfm's
Capacity continuous ventilation rate in cfms:
108
6
" round duct OR
Total ventilation (intermittent + continuous) rate in cfms:
215
" metal duct
Builders Associaton of Minnesota version 101014
City Inspection Dept. Copy
City Forester Copy
Applicant/Builder Copy
EAGAN
INDIVIDUAL RESIDENTIAL LOT
TREE PRESERVATION PLAN SUMMARY
CITY OF EAGAN FORESTRY DIVISION
651-675-5300
(BUILDER, PLEASE READ ATTACHMENTS)
Development Haven Woods
Lot Number
Address
Builder
2
Block Number 1
4002 Haven Woods Ct
SD Custom Homes
Phone Number: (651) 994-3997
Contact: Sean Doyle
Tree Protection Requirements:
Replacement Trees:
Attachments:
Additional Notes:
Tree Protection Fencing Needs to be installed and inspected around
back yard mitigation trees. No storage of materials or disturbance
allowed in critical root zone areas of newly planted trees. Call 651-
675-5300 to schedule an inspection
Oak Tree Pruning (Immediately seal wounds during April 1 to July 31)
Therapeutic Pruning Required
Retaining Wall To Be Installed
Other:
Not Required
As Follows: Per approved Tree Mitigation Plan, One (1) Category
"B" Greenspire Linden tree (>_ z.5-' caliper declduuus) tcrtre
installed after construct °EAGAN FORESTRY DIVISION
REVIEWED
Yes (Refer to attached BY
No
DATE 6/1 /2,0 -7/
z
C)
D
m
I
m
:NVld S3INOH I1O1Sf10-OS
II
:SNOIlb'n313 03SOdOlJd
0
D
0
0
0
0
2
m
z
0
0
0
0
m
O
m
:ss3aaav
:NOIld11:10S301VO31
:ON39313dVOSONH1
m
G)
m
z
0
rK
SOD
LIMITS
Required Mitigation Planting
4002 Haven Woods Ct
-(1) Greenspire Linden
J
\v\t kS1�
\` + + + + + + + `,\\ ,\�Y
+ +
�\1+++++++++ � ++"\``,•\\``\�\
\ "%
4 + + 4 + + + \\ \\`�.\
\." +
1,\\� + + +
;t``\,g ++++++���`\\i,
�,\\`r + + + t`,\ �`,�s-
,\\` I + + �i,\� ,,\\-
9— B:
—RM
LANDSCAPE SCHEDULE
MATURE
or'. KEY COMMON NAME BOTANICAL NAME SIZE H X W
REMARKS
DECIDUOUS TREE$
6
CH
COMMON HACKBERRY
Celtis occidentailis
2.5" CAL. 8&B
50' X SO'
STRacNr TRUNK. NO V-CROTCH
7
RM
AUTUMN BLAZE MAPLE
Acer x freemanii 'Jeffersred'
2.5" CAL. B&B
50' X 40'
SIRNCHT TRUNK. NO V-CROTCH
7
GL
GREENSPIRE LINDEN
Tilia Cordata 'Greenspire'
2.5" CAL. B&B
50' X 20'
S1RUCNT TRUNK. NO V-CROTCH
CONIFEROUS TREE$
31
BS
BLACKHILLS SPRUCE
Picea glauca densata
6' HT B&8
30' X 20'
rvu. FORM
1 1
NP
NORWAY PINE
Pinus resinoso
6' HT B&8
50' X 30'
FULL FORM
8
8F
BALSAM FIR
Abies balsamea
6' HT B&B
40' X 30'
ruu FORM
NOTE:
DECIDUOUS TREE: DIAMETER OF THE TREE MEASURED ONE FOOT ABOVE THE GROUND LEVEL IN CALIPER INCH.
CONIFEROUS TREE —IS MEASURED IN HEIGHT.
NVId S31NOH 110±S110-OS
SOOOM N3AVH
:SNOI1VA313 O3SOdOtid
:SS3jOOV
:NOIldI1:10S3O 1VO31
:ON39313dVOSONV1
4002 Haven Woods Court
EAGAN
Lakes
Storm Basin
Wetlands
Sections Numbers
Aerial Street Names
1 in=94ft
ti
City of Eagan, IS
April 23, 2021
Map Powered by DataLink
LOT SURVEY CHECKLIST FOR RESIDENTIAL
BUILDING PERMIT APPLICATION
Y Q
O z
❑✓ ❑
❑
0/❑✓
0 ❑
O ❑
O ❑
0 ❑
0 ❑
El El
O ❑
0 ❑
❑❑❑❑❑❑❑❑EI❑❑❑ Add/Change
❑ ❑
❑
❑ 0 ❑
O ❑ ❑
O ❑ ❑
0 ❑ ❑
O ❑ ❑
❑ ❑
❑ ❑
▪ ❑
No
O ❑ ❑
• El El
O ❑ ❑
0 ❑ ❑
❑ 0 ❑
0 ❑ ❑
No
No
0 ❑ Eli I❑ 0
D El
0 ❑ ❑
PROPERTY LEGAL:
Lot 2, Block 1, Haven Woods
DATE OF SURVEY: 4/15/21
LATEST REVISION: 57.7/
DOCUMENT STANDARDS
• Registered Land Surveyor signature and company
• Building Permit Applicant
• Legal description
• Address
• North arrow an scale
• House type (rambler, walkout, split w/o, split entry, lookout, etc.)
• Directional drainage arrows with slope/gradient %
• Proposed/existing sewer and water services & invert elevation
• Street name
• Driveway (grade & width - in R/W and back of curb, 22' max.)
• Lot Square Footage
• Lot Coverage
ELEVATIONS
Existing
• Property corners
• Top of curb at the driveway and property line extensions
• Elevations of any existing adjacent homes
• Adequate footing depth of structures due to adjacent utility trenches
• Waterways (pond, stream, etc.)
Proposed
• Garage floor
• Basement floor
• Lowest exposed elevation (walkout/window)
• Property corners
• Front and rear of home at the foundation
• PRV Required
PONDING AREA (if applicable
• Easement line
• NWL
• HWL
• Pond # designation
• Emergency Overflow Elevation
• Pond/Wetland buffer delineation
• Shoreland Zoning Overlay District
• Conservation Easements
DIMENSIONS
• Lot lines/Bearings & dimensions
• Right-of-way and street width (to back of curb)
• Proposed home dimensions including any proposed decks, overhangs greater than 2'
(i.e. all structures requiring permanent footings)
• Show all easements of record and any City utilities within those easements
• Setbacks of proposed structure and sideyard setback of adjacent existing structures
• Retaining wall requirements:
Reviewed By: Dave Westermayer
Date 5/8/21
sip/Zl
G:/1 Engineering/Forms/Cert. of Survey Checklist Fillable 03-16-2021
z
D
Z
z -1
x
m
rzr co
w
m m
? m m
A Z Z
N C �
N
r
0
C
71
z
0
0
N
O
O
:NV -Id S3WOH WO1Sf10OS
m D 03 O O
D7 mD0
G)O
mmm
-r0
O
0 3]
0
Z
73m>0c
0 < r F
xmO(np
m�0z
m G7
0mzm
-10(p JJ�
Z m
r-1(7ZZ
(/
)
O
Z T 0 m0 Z
71 w
`nrrTI r53
0�o 0x
DWO
2 0 r Z
=(/)0ZI
m DJ m
m[�
�O
O?
SGOOM N3AVH
7
0
o
0
v
3
0
a
v m
0
a
n
ti
D
0
O
0
0
3
A
0
2
3
elsay :IZOZ/Zl/SO
S
3
BEARINGS ARE ASSUMED PER PLAT
:SNOT±VA313 O3SOdO}id
0 m (n
0 z C
-IG)Jo
w m
m
x 33 m
Nzm
0-0
N' D
0 Z 37
�p0
G) m
D 0
0
z
rm
-o F.
Z -1
0
0)
m
0
c-
oo
m�
0 X 5D
<_
0 0 D
m II
x o
moD00
w p
N
D
II p X
N m
0)) m
m
N D
O 0
m o m
m
N
Z
0
m
CD
:V31:Ib' 101
1
x /
p /
w I /
p E /
J / Jn 1
X �f t 1 ' ,r� `° 1
HA VEN w �X
OQ 1
DS
03n iv
` N 1
> J I
s 70o48,59
„ ' X IL
8500
1N3Wf1NOW a333f18 ONV113M
0Vd ONIO1If18
31VM JO 3003
Sal01NOO 03SOd0ad
NVId 213d NOI1VA313
X08 OIb10313
X08 3NOHd3131
A
co
mn
-Cre
Art
rn
es
0
roi
8af3 JO d0l
318ISSOd IS3M01
D Ao
'0 N
>
Z
Z Z
z
00
D 0
H
o� c» 0.0
zo z0 ^Tio
0 0lo
o
2V) oo �O
-I rri
n
ril rn C3
m m 0
MO1d83A0 AON3O2J3W3
dO1S Baf1O
138 1N3Wf1NOW NOaI
JO NOIlo3810
0
A
D
2
D
m
NOI1VA313 03SOd0ad
r
:NOIldI1:loSO 1V931
X
0
N0I1VA313 ONI1SIX3
:aN3931 3dVOSONV1
m
0
Z
❑
Sd Custom Homes
HVAC Load Calculations
for
Sd Custom Homes
4002 Haven Doods Ct
Eagan,mn
R HV HvlipEC LoLN01 AL
HVAADs
Prepared By:
Sean
Sean Doyle
750 Main St
Mendota Heights, MN 55118
Tuesday, April 20, 2021
Rhva:'Residential aLight Commercial nvxoLoads
LofgrenHtg.8*C
Farmington, MN 55024
Elite Software Development, Inc.
�
8UCustom Homes
Page 2
�
''~x~~^Report
General Project Information
Project Tide:
Project Date:
Client Name:
Client Address:
Client City:
Company Name:
Company Representative:
Company Address:
�Company City:
SdCustom Homes
Tuesday, April 2O.2021
SdCustom Homes
40O2Haven DoodsCX
Eogan.mn
Sean Doyle
Sean
750 Main St
Mendota Hoighta, MN 55118
Dcsi-qn[]oto
Reference City: Minneapolis, Minnesota
Building Orientation: Front door faces West
Daily Temperature Range: Medium
Latitude: 44 Degrees
Elevation: 834 ft.
Altitude Factor: 0.870
Elevation Sensible Adj. Factor: 1.000
Elevation Total Adj. Factor: 1.000
Elevation Heating Adj. Factor: 1.000
Elevation Heating Adj. Factor: 1.000
Winter:
Summer
Outdoor
Dry Bulb
-15
88
Outdoor Outdoor Indoor Indoor Grains
Wet Bulb ReiHum ReiHum Dry Bulb Difference
'15.33 80% n/a 72 n/o
72 47% 50Y6 75 29
I �Check Fkpurem
Total Building Supply CFK8: 1.614 CF[NPer Square fL: 0.322
Square ft. ofRoom Area: 5.018 Square ft. Per Ton: 1,449
Volume (ft3)ofCond. Space: 43.O4Q
�
Building Loads
Total Heating Required Including Ventilation Air: 69.322 Btuh 60.322 K8BH
Total Sensible Gain: 34.781 Btuh 84 Y6
Total Latent Gain: 8.788 Btuh 10 96
Total Cooling Required Including Ventilation Air: 41,569 Btuh 3.46 Tons (Based On Sensible + Latent)
� Notes
Calculations are based on8th edition ofACCAManual J.
All computed results are estimates aobuilding use and weather may vary.
Rhvac - Residential & Light Commercial HVAC Loads
Lofgren Htg. & NC
Farmington, MN 55024
Elite Software Development, Inc.,
Sd Custom Homes
Page 3'
Miscellaneous Report
System 1 Whole House
Input Data
Outdoor Outdoor Outdoor Indoor Indoor Grains
Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference
Winter:
Summer:
Duct Sizing Inputs
-15
88
-15.33
72
80%
47%
n/a
50%
72
75
n/a
29.27
li
Main Trunk
Calculate: Yes
Use Schedule: No
Roughness Factor: 0.00300
Pressure Drop: 0.1000 in.wg./100 ft.
Minimum Velocity: 650 ft./min
Maximum Velocity: 900 ft./min
Minimum Height: 8 in.
Maximum Height: 10 in.
Outside Air Data
Runouts
Yes
No
0.01000
0.1000 in.wg./100 ft.
450 ft./min
750 ft./min
6 in.
6 in.
Infiltration Specified:
Infiltration Actual:
Above Grade Volume:
Total Building Infiltration:
Total Building Ventilation:
Winter Summer
0.250 AC/hr 0.130 AC/hr
153 CFM 80 CFM
0.250 AC/hr
X 36,704 Cu.ft.
9,176 Cu.ft./hr
X 0.0167
153 CFM
140 CFM
0.130 AC/hr
X 36 704 Cu.ft.
4,772 Cu.ft./hr
X 0.0167
80 CFM
70 CFM
---System 1---
Infiltration & Ventilation Sensible Gain Multiplier: 13.87 = (1.10 X 0.970 X 13.00 Summer Temp. Difference)
Infiltration & Ventilation Latent Gain Multiplier: 19.31 = (0.68 X 0.970 X 29.27 Grains Difference)
Infiltration & Ventilation Sensible Loss Multiplier: 92.85 = (1.10 X 0.970 X 87.00 Winter Temp. Difference)
Winter Infiltration Specified: 0.250 AC/hr (153 CFM), Construction: Unknown
Summer Infiltration Specified: 0.130 AC/hr (80 CFM), Construction: Unknown
C:\ ...\4002 HAVEN WOODS EAGAN 04202021.rhv Tuesday, April 20, 2021, 11:40 AM
Rhvac - Residential & Light Commercial HVAC Loads
Lofgren Htg. & A/C
Farmington, MN 5502.4
Elite Software Development, Inc.
Sd Custom Homes
Page 4
Load Preview Report
Scope
Has
AED
Net ft.'
Ton /Tor
Sen
Area Gain
Lat
Gain
Net
Gain
Sen
Loss
Sys
Htg
CFM
Sys
CIg
CFM
Sys
Act
CFM
Duct
Size
Building 3.46 1,449 5,018 34,781 6,788 41,569 69,322 1,349 1,614 1,614
System 1 Yes 3.46 1,449 5,018 34,781 6,788 41,569 69,322 1,349 1,614 1,614 28x1C
Ventilation 340 1,352 1,692 4,550
Zone 1 5,018 34,441 5,436 39,877 64,772 1,349 1,614 1,614 28x1C
1-Main Level 1,495 13,463 2,054 15,517 23,833 496 631 631 7--6
2-Upper Level 2,113 16,583 2,593 19,176 25,357 528 777 777 9--6
3-Lower Level 1,410 4,395 789 5,184 15,582 324 206 206 2--6
C:\ ...\4002 HAVEN WOODS EAGAN 04202021.rhv Tuesday, April 20, 2021, 11:40 AM
Rhvac - Residential & Light Commercial HVAC Loads
Lofgren Htg. & A/C
Farmington, MN 55024
Elite Software Development, Inc.
Sd Custom Homes
Page 5_1
Duct Size Preview
Room or
Duct Name
Minimum Maximum Rough Design Actua SP
Velocity Velocity Factor L/10C U10 Loss
Duct Duct
Velocity Lengtr
Htg
Flow
Clg
Flow
Act.
Flow
Duct
Size
System 1
Supply Runouts
Zone 1
1-Main Level
2-Upper Level
3-Lower Level
Other Ducts
Supply Main Trunk
450 750 0 0.1 0.1
450 750 0 0.1 0.1
450 750 0 0.1 0.2
650 900 0 0.1 0.1
458.9
439.6
524.3
829.8
496 El
528
324
1,349
631 7--6
777 9--6
206 2--6
1,614 28x1C
Summary
System 1
Heating Flow: 1349
Cooling Flow: 1614
C:\ ...\4002 HAVEN WOODS EAGAN 04202021.rhv Tuesday, April 20, 2021, 11:40 AM
Rhvac - Residential & Light Commercial HVAC Loads
Lofgren Htg. & A/C
Farmington, MN 55024
Elite Software Development, Inc.''
Sd Custom Homes
Page 6
System 1 - Whole House - Adequate Exposure Diversity Test
Heat Gain, Btuh
50,000
40,000-
30,000
20,000
10,000
0
8 am
Test For Adequate Exposure Diversity
9 am
13.0% Diff. from Avg.
10 am 11 am 12 pm 1 pm 2 pm 3 pm 4 pm 5 pm
/ Average Glass 1.3 x Average I Hourly Glass Gain I Hourly Total Net
Sensible Gain Glass Gain Gain
Over 12 Hours
6 pm
7 pm
AED Calculation Summary
--- SYSTEM HAS ADEQUATE EXPOSURE DIVERSITY. ---
System is on N, E, S, W rosette.
Peak load exceeds 12-hour average load by 13.0%.
AED Excursion (amount by which peak exceeds 1.3 x average): 0 Btuh
Definition: A system has adequate exposure diversity if the peak -hour glass load for the entire conditioned space does not
exceed the average glass load for the entire conditioned space by more than 30 percent.
C:\ ...\4002 HAVEN WOODS EAGAN 04202021.rhv Tuesday, April 20, 2021, 11:40 AM
Rhvac - Residential & Light Commercial HVAC Loads
Lofgren Htg. & A/C
Farmington, MN 55024
Elite Software Development, Inc.
Sd Custom Homes
Page 7
System 1 - Whole House - Psychrometric Chart
ZC Zone (Room) Condition
LC Leaving Coil Condition
SD Supply Duct Temperature Rise
HRV Heat Recovery Ventilator
OC Outdoor Condition
EC Entering Coil Condition
DTF Draw Through Fan Sensible Gain
F sr�
/rf / HRV:'.
f V
L^J
•
><'-'1/4
CO 0
107 grflb
70
56
42
28
14
go
li
C:\ ...\4002 HAVEN WOODS EAGAN 04202021.rhv Tuesday, April 20, 2021, 11:40 AM
Rhvac - Residential & Light Commercial HVAC Loads
Lofgren Htg. & A/C
Farmington, MN 55024
Elite Software Development, Inc.
Sd Custom Homes
Page 8
Total Building Summary Loads
Component Area Sen Lat Sen Total
Description Quan Loss Gain Gain Gain
4A-la-o: Glazing -Double pane low-e (e = 0.20 or less), 357 9,318 0 9,381 9,381
operable window, e=0.20 on surface 2, wood with
metal clad frame, u-value 0.3, SHGC 0.28
4A-la-o: Glazing -Double pane low-e (e = 0.20 or less), 114 2,976 0 3,268 3,268
operable window, e=0.20 on surface 2, wood with
metal clad frame, u-value 0.3, SHGC 0.28
4A-la-o: Glazing -Double pane low-e (e = 0.20 or less), 164 4,565 0 4,208 4,208
operable window, e=0.20 on surface 2, wood with
metal clad frame, u-value 0.32, SHGC 0.23
4A-la-o: Glazing -Double pane low-e (e = 0.20 or less), 56 1,364 0 920 920
operable window, e=0.20 on surface 2, wood with
metal clad frame, u-value 0.28, SHGC 0.25
4A-la-o: Glazing -Double pane low-e (e = 0.20 or less), 62 1,672 0 1,583 1,583
operable window, e=0.20 on surface 2, wood with
metal clad frame, u-value 0.31, SHGC 0.23
11 N: Door -Metal - Polystyrene Core 42 1,096 0 302 302
12F-0sw: Wall -Frame, R-21 insulation in 2 x 6 stud 3515 19,878 0 3,038 3,038
cavity, no board insulation, siding finish, wood studs
15B0-15sf-10: Wall -Basement, , R-15 board insulation to 810 2,959 0 0 0
floor, no interior finish, 10' floor depth
16B-50: Roof/Ceiling-Under Attic with Insulation on Attic 2113 3,677 0 2,028 2,028
Floor (also use for Knee Walls and Partition
Ceilings), Vented Attic, No Radiant Barrier, Dark
Asphalt Shingles or Dark Metal, Tar and Gravel or
Membrane, R-50 insulation
21A-24: Floor -Basement, Concrete slab, any thickness, 2 1410 3,067 0 0 0
or more feet below grade, no insulation below floor,
any floor cover, shortest side of floor slab is 24' wide
Subtotals for structure: 50,572 0 24,728 24,728
People: 7 1,400 1,610 3,010
Equipment: 2,500 7,000 9,500
Lighting: 0 0 0
Ductwork: 0 0 0 0
Infiltration: Winter CFM: 153, Summer CFM: 80 14,200 1,536 1,103 2,639
Ventilation: Winter CFM: 140, Summer CFM: 70 4,550 1,352 340 1,692
Total Building Load Totals: 69,322 6,788 34,781 41,569
Check Figures
Total Building Supply CFM:
Square ft. of Room Area:
Volume (ft3) of Cond. Space:
Building Loads
1,614
5,018
43,049
CFM Per Square ft.: 0.322
Square ft. Per Ton: 1,449
Total Heating Required Including Ventilation Air: 69,322 Btuh
Total Sensible Gain: 34,781 Btuh
Total Latent Gain: 6,788 Btuh
Total Cooling Required Including Ventilation Air: 41,569 Btuh
Notes
Calculations are based on 8th edition of ACCA Manual J.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads.
69.322 MBH
84 %
16 %
3.46 Tons (Based On Sensible + Latent)
C:\ ...\4002 HAVEN WOODS EAGAN 04202021.rhv Tuesday, April 20, 2021, 11:40 AM
Rhvac - Residential & Light Commercial HVAC Loads
Lofgren Htg. & A/C
Farmington, MN_ 55024
Elite Software Development, Inc.
Sd Custom Homes
Page 9
Building Pie Chart
Building
Loss
69,322
Btuh
Building
Gain
41,569
Btuh
Wall 33%
Floor 4%
Roof 5%
Roof 5%
Wall 7%
Glass 47%
Ventilation 7%
Infiltration 20%
Door 2%
Glass 29%
Ventilation 4%
Infiltration 6%
Equipment 23%
People 7%
Door 1
C:\ ...\4002 HAVEN WOODS EAGAN 04202021.rhv
Tuesday, April 20, 2021, 11:40 AM
Rhvac - Residential & Light Commercial HVAC Loads
Lofgren Htg. & A/C
Farmington, MN 55024
Elite Software Development, Inc.
Sd Custom Homes
Page 10_.
Building Bar Graph
25,000
20,000
15,000
Building
Loss
69,322 10,000
Btuh
5,000
Building
Gain
41,569
Btuh
0
20,000
15,000
10,000
5,000
0
Roof 5% Glass 47% People 7% Infiltration 6%
Wall 7% Door 1 % Equipment 23% Ventilation 4%
Floor 4% Wall 33% Door 2% Ventilation 7%
Roof 5% Glass 29% Infiltration 20%
C:\ ...\4002 HAVEN WOODS EAGAN 04202021.rhv
Tuesday, April 20, 2021, 11:40 AM
Rhvac - Residential & Light Commercial HVAC Loads
Lofgren Htg. & A/C
Farmington, MN 55024
Elite Software Development, Inc.,
Sd Custom Homes',
Page 11
System 1 Whole House Summary Loads
Component
Description
4A-la-o: Glazing -Double pane low-e (e = 0.20 or less),
operable window, e=0.20 on surface 2, wood with
metal clad frame, u-value 0.3, SHGC 0.28
4A-la-o: Glazing -Double pane low-e (e = 0.20 or less),
operable window, e=0.20 on surface 2, wood with
metal clad frame, u-value 0.3, SHGC 0.28
4A-la-o: Glazing -Double pane low-e (e = 0.20 or less), 164 4,565
operable window, e=0.20 on surface 2, wood with
metal clad frame, u-value 0.32, SHGC 0.23
4A-la-o: Glazing -Double pane low-e (e = 0.20 or less), 56 1,364
operable window, e=0.20 on surface 2, wood with
metal clad frame, u-value 0.28, SHGC 0.25
4A-la-o: Glazing -Double pane low-e (e = 0.20 or less), 62 1,672
operable window, e=0.20 on surface 2, wood with
metal clad frame, u-value 0.31, SHGC 0.23
11 N: Door -Metal - Polystyrene Core 42 1,096
12F-0sw: Wall -Frame, R-21 insulation in 2 x 6 stud 3515 19,878
cavity, no board insulation, siding finish, wood studs
15B0-15sf-10: Wall -Basement, , R-15 board insulation to 810 2,959
floor, no interior finish, 10' floor depth
16B-50: Roof/Ceiling-Under Attic with Insulation on Attic 2113 3,677
Floor (also use for Knee Walls and Partition
Ceilings), Vented Attic, No Radiant Barrier, Dark
Asphalt Shingles or Dark Metal, Tar and Gravel or
Membrane, R-50 insulation
21A-24: Floor -Basement, Concrete slab, any thickness, 2 1410 3,067 0 0 0
or more feet below grade, no insulation below floor,
any floor cover, shortest side of floor slab is 24' wide
Subtotals for structure: 50,572 0 24,728 24,728
People: 7 1,400 1,610 3,010
Equipment: 2,500 7,000 9,500
Lighting: 0 0 0
Ductwork: 0 0 0 0
Infiltration: Winter CFM: 153, Summer CFM: 80 14,200 1,536 1,103 2,639
Ventilation: Winter CFM: 140, Summer CFM: 70 4,550 1,352 340 1,692
Area Sen
Quan Loss
357 9,318
114 2,976
System 1 Whole House Load Totals: 69,322
Lat Sen Total
Gain Gain Gain'.
0 9,381 9,381
0 3,268 3,268
0 4,208 4,208
0 920 920
0 1,583 1,583
0 302 302
0 3,038 3,038
0 0 0
0 2,028 2,028
6,788 34,781 41,569
Check Figures
Supply CFM:
Square ft. of Room Area:
Volume (ft') of Cond. Space:
System Loads
1,614
5,018
43,049
CFM Per Square ft.: 0.322
Square ft. Per Ton: 1,449
Total Heating Required Including Ventilation Air: 69,322 Btuh
Total Sensible Gain: 34,781 Btuh
Total Latent Gain: 6,788 Btuh
Total Cooling Required Including Ventilation Air: 41,569 Btuh
Notes
Calculations are based on 8th edition of ACCA Manual J.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads.
69.322 MBH
84 %
16 %
3.46 Tons (Based On Sensible + Latent)
C:\ ...\4002 HAVEN WOODS EAGAN 04202021.rhv Tuesday, April 20, 2021, 11:40 AM
Rhvac - Residential & Light Commercial HVAC Loads
Lofgren Htg. & A/C
Farmington, MN 55024
Elite Software Development, Inc.',
Sd Custom Homes
Page 12
System 1 Whole House Pie Chart
System
1 Whole
House
Loss
69,322
Btuh
System
1 Whole
House
Gain
41,569
Btu h
Wall 33%
Wall 7%
Glass 47%
Floor 4%
Roof 5%
Ventilation 7%
Infiltration 20%
Door 2%
Glass 29%
Roof 5% Ventilation 4%
Infiltration 6%
Equipment 23%
People 7%
Door 1%
C:\ ...\4002 HAVEN WOODS EAGAN 04202021.rhv
Tuesday, April 20, 2021, 11:40 AM
Rhvac - Residential & Light Commercial HVAC Loads
Lofgren Htg. & NC
Farmington, MN 55024
Elite Software Development, Inc.'
Sd Custom Homes
Page 13
System 1 Whole House Bar Graph
25,000
20,000
System 15,000
1 Whole
House
Loss 10,000
69,322
Btuh
5,000
System
1 Whole
House
Gain
41,569
Btuh
A
0 1 1
Floor 4% Wall 33% Door 2% Ventilation 7%
Roof 5% Glass 29% Infiltration 20%
20,000
15,000
10,000
5,000
0
Roof 5% Glass 47%
People 7% Infiltration 6%
Wall 7% Door 1% Equipment 23% Ventilation 4%
C:\ ...\4002 HAVEN WOODS EAGAN 04202021.rhv
Tuesday, April 20, 2021, 11:40 AM
Rhvac - Residential & Light Commercial HVAC Loads
Lofgren Htg. & NC
Farmington, MN 55024
Elite Software Development, Inc.
Sd Custom Homes
Page 14,
System 1, Zone 1 Summary Loads (Average Load Procedure for Rooms)
Component Area Sen Lat Sen Total
Description Quan Loss Gain Gain Gain
4A-la-o: Glazing -Double pane low-e (e = 0.20 or less), 357 9,318 0 9,381 9,381
operable window, e=0.20 on surface 2, wood with
metal clad frame, u-value 0.3, SHGC 0.28
4A-la-o: Glazing -Double pane low-e (e = 0.20 or less), 114 2,976 0 3,268 3,268
operable window, e=0.20 on surface 2, wood with
metal clad frame, u-value 0.3, SHGC 0.28
4A-la-o: Glazing -Double pane low-e (e = 0.20 or less), 164 4,565 0 4,208 4,208
operable window, e=0.20 on surface 2, wood with
metal clad frame, u-value 0.32, SHGC 0.23
4A-la-o: Glazing -Double pane low-e (e = 0.20 or less), 56 1,364 0 920 920
operable window, e=0.20 on surface 2, wood with
metal clad frame, u-value 0.28, SHGC 0.25
4A-la-o: Glazing -Double pane low-e (e = 0.20 or less), 62 1,672 0 1,583 1,583
operable window, e=0.20 on surface 2, wood with
metal clad frame, u-value 0.31, SHGC 0.23
11 N: Door -Metal - Polystyrene Core 42 1,096 0 302 302
12F-0sw: Wall -Frame, R-21 insulation in 2 x 6 stud 3515 19,878 0 3,038 3,038
cavity, no board insulation, siding finish, wood studs
15B0-15sf-10: Wall -Basement, , R-15 board insulation to 810 2,959 0 0 0
floor, no interior finish, 10' floor depth
16B-50: Roof/Ceiling-Under Attic with Insulation on Attic 2113 3,677 0 2,028 2,028
Floor (also use for Knee Walls and Partition
Ceilings), Vented Attic, No Radiant Barrier, Dark
Asphalt Shingles or Dark Metal, Tar and Gravel or
Membrane, R-50 insulation
21A-24: Floor -Basement, Concrete slab, any thickness, 2 1410 3,067 0 0 0
or more feet below grade, no insulation below floor,
any floor cover, shortest side of floor slab is 24' wide
Subtotals for structure: 50,572 0 24,728 24,728
People: 7 1,400 1,610 3,010
Equipment: 2,500 7,000 9,500
Lighting: 0 0 0
Ductwork: 0 0 0 0
Infiltration: Winter CFM: 153, Summer CFM: 80 14,200 1,536 1,103 2,639
System 1, Zone 1 Load Totals: 64,772 5,436 34,441 39,877
Check Figures
Supply CFM: 1,614
Square ft. of Room Area: 5,018
Volume (ft3) of Cond. Space: 43,049
Zone Loads
CFM Per Square ft.: 0.322
Square ft. Per Ton: 1,510
Total Heating Required:
Total Sensible Gain:
Total Latent Gain:
Total Cooling Required:
Notes
64,772 Btuh
34,441 Btuh
5,436 Btuh
39,877 Btuh
64.772 MBH
86 %
14 %
3.32 Tons (Based On Sensible + Latent)
Calculations are based on 8th edition of ACCA Manual J.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads.
C:\ ...\4002 HAVEN WOODS EAGAN 04202021.rhv Tuesday, April 20, 2021, 11:40 AM
Rhvac - Residential & Light Commercial HVAC Loads
Lofgren Htg. & NC
Farmington, MN 55024
Elite Software Development, Inc.
Sd Custom Homes
Page 15
System 1, Zone 1 Pie Chart
System
1, Zone
1
Loss
64,772 Wall35%
Btuh
System
1, Zone
1
Gain
39,877
Btuh
Floor 5%
Roof 6%
Roof 5%
Wall 8%
Glass 49%
Infiltration 22%
Door 2%
Glass 31
Infiltration 7%
Equipment 24%
People 8%
Door 1 %
C:\ ...\4002 HAVEN WOODS EAGAN 04202021.rhv
Tuesday, April 20, 2021, 11:40 AM
Rhvac - Residential & Light Commercial HVAC Loads
Lofgren Htg. & A/C
Farmington, MN 55024
Elite Software Development, Inc.'.
Sd Custom Homes
Page 16
System 1, Zone 1 Bar Graph
25,000
20,000
System 15,000
1, Zone
1
Loss 10,000
64,772
Btuh
5,000
System
1, Zone
1
Gain
39,877
Btuh
0
Floor 5% Wall 35% Door 2%
Roof 6% Glass 31% Infiltration 22%
20,000
15,000
10,000
5,000
0
Roof 5% Glass 49% People 8% Infiltration 7%
Wall 8% Door 1% Equipment 24%
C:\ ...\4002 HAVEN WOODS EAGAN 04202021.rhv
Tuesday, April 20, 2021, 11:40 AM
Rhvac - Residential & Light Commercial HVAC Loads
Lofgren Htg. & A/C
Farmington, MN 55024
Elite Software Development, Inc.
Sd Custom Homes
Page 17
Detailed Room Loads - Room 1 - Main Level (Average Load Procedure
General
Calculation Mode:
Room Length:
Room Width:
Area:
Ceiling Height:
Volume:
Number of Registers:
Runout Air:
Runout Duct Size:
Runout Air Velocity:
Runout Air Velocity:
Actual Loss:
Item Area
Description Quantity
N -Wall-12F-0sw 40 X 9 360
S -Wall-12F-0sw 40 X 9 320
E -Wall-12F-0sw 62 X 9 364
W -Wall-12F-0sw 62 X 9 444
W-Door-11 N 3 X 7 21
W-Door-11 N 3 X 7 21
S -GIs-4A-1 a-o shgc-0.28 0%S 7
S -GIs-4A-1 a-o shgc-0.28 0%S 7
S -GIs-4A-1 a-o shgc-0.28 0%S 7
S -GIs-4A-1 a-o shgc-0.28 0%S 7
S -GIs-4A-1 a-o shgc-0.28 0%S 12
E -GIs-4A-1 a-o shgc-0.28 0%S 10
E -GIs-4A-1 a-o shgc-0.28 0%S 20
E -GIs-4A-1 a-o shgc-0.23 0%S 72
E -GIs-4A-1 a-o shgc-0.23 0%S 92
W -GIs-4A-1 a-o shgc-0.28 0%S 36
W -GIs-4A-1 a-o shgc-0.28 0%S 36
Subtotals for Structure:
Infil.: Win.: 65.1, Sum.: 33.9 1,836
People: 200 lat/per, 230 sen/per: 2
Equipment:
Room Totals:
Htg. & clg.
1,495.0
1.0
1,495.0
9.0
13,455.0
7
90
6
459
459
0.132
ft.
ft.
sq.ft.
ft.
cu.ft.
CFM
in.
ft./min.
ft./min.
in.wg./100 ft.
-U-
Value
0.065
0.065
0.065
0.065
0.300
0.300
0.300
0.300
0.300
0.300
0.300
0.300
0.300
0.320
0.320
0.300
0.300
Occurrences:
System Number:
Zone Number:
Supply Air:
Supply Air Changes:
Req. Vent. Clg:
Actual Winter Vent.:
Percent of Supply.:
Actual Summer Vent.:
Percent of Supply:
Actual Winter Infil.:
Actual Summer Infil.:
Htg Sen Clg
HTM Loss HTM
5.7
5.7
5.7
5.7
26.1
26.1
26.1
26.1
26.1
26.1
26.1
26.1
26.1
27.8
27.8
26.1
26.1
2,036 0.9
1,810 0.9
2,058 0.9
2,511 0.9
548 7.2
548 7.2
183 16.7
183 16.7
183 16.7
183 16.7
313 16.7
261 30.1
522 30.1
2,004 25.7
2,561 25.7
940 30.1
940 30.1
17,784
3.295 6,049
23,833
0.256 654
400
1,000
1
1
631 CFM
2.8 AC/hr
0 CFM
52 CFM
8 %
27 CFM
4 %
65 CFM
34 CFM
Lat
Gain
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Sen
Gain
311
277
315
384
151
151
117
117
117
117
200
301
601
1,847
2,361
1,083
1,083
0 9,533
470
460
3,000
2,054 13,463
C:\ ...\4002 HAVEN WOODS EAGAN 04202021.rhv Tuesday, April 20, 2021, 11:40 AM
Rhvac - Residential & Light Commercial HVAC Loads
Lofgren Htg. & A/C
Farmington MN 55024
Elite Software Development, Inc.
Sd Custom Homes
Page 18
Detailed Room Loads - Room 2 -
General
Calculation Mode:
Room Length:
Room Width:
Area:
Ceiling Height:
Volume:
Number of Registers:
Runout Air:
Runout Duct Size:
Runout Air Velocity:
Runout Air Velocity:
Actual Loss:
Item
Description
N -Wall-12F-0sw 40 X 8
S -Wall-12F-0sw 40 X 8
E -Wall-12F-0sw 64 X 8
W -Wall-12F-0sw 64 X 8
N -GIs-4A-la-o shgc-0.28 100%S
N -GIs-4A-la-o shgc-0.28 100%S
N -GIs-4A-1 a-o shgc-0.25 100%S
S -GIs-4A-1 a-o shgc-0.28 0%S
S -GIs-4A-1 a-o shgc-0.25 0%S
S -GIs-4A-1 a-o shgc-0.25 0%S
E -GIs-4A-1 a-o shgc-0.28 0%S
E -GIs-4A-1 a-o shgc-0.28 0%S
E -GIs-4A-1 a-o shgc-0.28 0%S
E -GIs-4A-1 a-o shgc-0.28 0%S
W -GIs-4A-1 a-o shgc-0.28 0%S
W -GIs-4A-1 a-o shgc-0.28 0%S
W -GIs-4A-1 a-o shgc-0.28 0°/oS
W -GIs-4A-1 a-o shgc-0.25 0%S
W -GIs-4A-1 a-o shgc-0.28 0%S
UP-Ceil-16B-50 2113 X 1
Subtotals for Structure:
Infil.: Win.: 59.0, Sum.: 30.7
People: 200 lat/per, 230 sen/per:
Equipment:
Room Totals:
Upper Level [Average Load Procedure)
Htg. & clg.
2,113.0 ft.
1.0 ft.
2,113.0 sq.ft.
8.0 ft.
16,904.0 cu.ft.
9
86
6
440
440
0.121
1
System Number: 1
Zone Number: 1
Supply Air: 777 CFM
Supply Air Changes: 2.8 AC/hr
Req. Vent. Clg: 0 CFM
Actual Winter Vent.: 55 CFM
CFM Percent of Supply.: 7 %
in. Actual Summer Vent.: 34 CFM
ft./min. Percent of Supply: 4 %
ft./min. Actual Winter Infil.: 59 CFM
in.wg./100 ft. Actual Summer Infil.: 31 CFM
Occurrences:
Area -U- Htg Sen Clg Lat Sen
Quantity Value HTM Loss HTM Gain Gain
294 0.065 5.7 1,663 0.9 0 254
272 0.065 5.7 1,538 0.9 0 235
396 0.065 5.7 2,239 0.9 0 342
366 0.065 5.7 2,070 0.9 0 316
10 0.300 26.1 261 9.2 0 92
10 0.300 26.1 261 9.2 0 92
6 0.280 24.4 146 8.3 0 50
18 0.300 26.1 470 16.7 0 300
18 0.280 24.4 438 15.0 0 270
12 0.280 24.4 292 15.0 0 180
42 0.300 26.1 1,096 30.1 0 1,263
10 0.300 26.1 261 30.1 0 301
20 0.300 26.1 522 30.1 0 601
44 0.300 26.1 1,148 30.1 0 1,323
42 0.300 26.1 1,096 30.1 0 1,263
10 0.300 26.1 261 30.1 0 301
42 0.300 26.1 1,096 30.1 0 1,263
10 0.280 24.4 244 27.0 0 270
42 0.300 26.1 1,096 30.1 0 1,263
2113 0.020 1.7 3,677 1.0 0 2,028
19,875 0 12,007
1,664 3.294 5,482 0.256 593 426
5 1,000 1,150
1,000 3,000
25,357 2,593 16,583
C:\ ...\4002 HAVEN WOODS EAGAN 04202021.rhv Tuesday, April 20, 2021, 11:40 AM
Rhvac - Residential & Light Commercial HVAC Loads
Lofgren Htg. & A/C
Farmington, MN 55024
Elite Software Development, Inc.'
Sd Custom Homes
Page 19_
Detailed Room Loads - Room 3 -
General
Calculation Mode:
Room Length:
Room Width:
Area:
Ceiling Height:
Volume:
Number of Registers:
Runout Air:
Runout Duct Size:
Runout Air Velocity:
Runout Air Velocity:
Actual Loss:
Htg. & clg.
1,410.0
1.0
1,410.0
9.0
12,690.0
2
103
6
524
524
0.171
Lower Level (Average Load Procedure)
ft.
ft.
sq.ft.
ft.
cu.ft.
CFM
in.
ft./min.
ft./min.
in.wg./100 ft.
Occurrences:
System Number:
Zone Number:
Supply Air:
Supply Air Changes:
Req. Vent. Clg:
Actual Winter Vent.:
Percent of Supply.:
Actual Summer Vent.:
Percent of Supply:
Actual Winter Infil.:
Actual Summer Infil.:
1
1
206 CFM
1.0 AC/hr
0 CFM
34 CFM
16 %
9 CFM
4 %
29 CFM
15 CFM
Item
Description
Area
Quantity
-U-
Value
Htg
HTM
Sen
Loss
Clg
HTM
Lat
Gain
Sen
Gain
E -Wall-12F-Osw 50 X 9
S -Wall-12F-0sw 40 X 9
N -Wall-15B0-15sf-10 40 X 9
W -Wall-15B0-15sf-10 50 X 9
E -GIs-4A-1 a-o shgc-0.28 0%S
E -GIs-4A-1 a-o shgc-0.23 0%S
S -GIs-4A-1 a-o shgc-0.28 0%S
S -GIs-4A-1 a-o shgc-0.28 0%S
S -GIs-4A-1 a-o shgc-0.25 0%S
Floor-21A-24 1 X 1410
Subtotals for Structure:
Infil.: Win.: 28.7, Sum.: 14.9
Equipment:
Room Totals:
373
326
360
450
15
62
12
12
10
1410
810
0.065
0.065
0.042
0.042
0.300
0.310
0.300
0.300
0.280
0.025
5.7 2,109
5.7 1,844
3.7 1,315
3.7 1,644
26.1 392
27.0 1,672
26.1 313
26.1 313
24.4 244
2.2 3,067
12,913
3.295 2,669
15,582
0.9
0.9
0.0
0.0
30.1
25.5
16.7
16.7
15.0
0.0
0 322
0 282
0 0
0 0
0 451
0 1,583
0 200
0 200
0 150
0 0
0
0.256 289
500
3,188
207
1,000
789 4,395
C:\ ...\4002 HAVEN WOODS EAGAN 04202021.rhv Tuesday, April 20, 2021, 11:40 AM
Rhvac - Residential & Light Commercial HVAC Loads
Lofgren Htg. & A/C
Farmington, MN 55024
Elite Software Development, Inc.
Sd Custom Homes
Page 20
Room Cooling and Heating Loads Bar Graphs
Main Level
Upper Level
Lower Level
0 5,000 10,000 15,000 20,000 25,000 30,000
Btuh
Cooling
1 Heating
C:\ ...\4002 HAVEN WOODS EAGAN 04202021.rhv Tuesday, April 20, 2021, 11:40 AM
Rhvac - Residential & Light Commercial HVAC Loads
Lofgren Htg. & A/C
Farmington, MN5502_4
Elite Software Development, Inc.
Sd Custom Homes
Page 21
Room Cooling Loads Bar Graphs
Main Level
Upper Level
Lower Level
0
5,000 10,000 15,000 20,000
Btuh
Sensible
Latent
C:\ ...\4002 HAVEN WOODS EAGAN 04202021.rhv Tuesday, April 20, 2021, 11:40 AM
Rhvac - Residential & Light Commercial HVAC Loads
Lofgren Htg. & A/C
Farm n_ loon _MN_55024
Elite Software Development, Inc.',
Sd Custom Homes
Page 22
System 1 Room Load Summary
Room
No Name
Area
SF
Htg
Sens
Btuh
Min
Htg
CFM
Run Run
Duct Duct
Size Vel
Clg
Sens
Btuh
Clg
Lat
Btuh
Min Act
Clg Sys
CFM CFM
---Zone 1---
1 Main Level 1,495
2 Upper Level 2,113
3 Lower Level 1,410
Ventilation
System 1 total 5,018
System 1 Main Trunk Size:
Velocity:
Loss per 100 ft.:
Cooling System Summary
23,833 496
25,357 528
15,582 324
4,550
69,322 1,349
28x10 in.
830 ft./min
0.091 in.wg
7-6
9-6
2-6
459
440
524
13,463
16,583
4,395
2,054
2,593
789
340 1,352
631
777
206
631
777
206
34,781 6,788 1,614 1,614
Cooling
Tons
Sensible/Latent
Split
Sensible
Btuh
Latent
Btuh
Total
Btuh
Net Required:
Actual:
Equipment Data
Type:
Model:
Indoor Model:
Brand:
Description:
Efficiency:
Sound:
Capacity:
Sensible Capacity:
Latent Capacity:
3.46
1.00
84% / 16%
77% / 23%
Heating System
Natural Gas Furnace
QC-F38-E78-G
Quikcool FE Series
Hi Efficiency Furnace
78.3 AFUE
38,000 Btuh
n/a
n/a
34,781
9,240
6,788
2,760
Cooling System
Standard Air Conditioner
QC-C12
S12
Quikcool AS Series
Standard Efficiency Air Condit
12.4 SEER
8.1 bels
12,000 Btuh
9,240 Btuh
2,760 Btuh
41,569
12,000
C:\ ...\4002 HAVEN WOODS EAGAN 04202021.rhv Tuesday, April 20, 2021, 11:40 AM
Ventilation, Makeup and Combustion Air Calculations
Submittal Form for New Dwellings
These blank submittal forms and Instructions are evadable at the City of 11111111website and at Oty Hail. The completed Farm mid be
submitted In duplicate at the tittle of application for a meeltanncaI permit for nsw construction. Additional fortes maybe downloaded and
printed et: fittp://cityaredina.comidepartrnents/L3•09_huikling.htm
a..mar,. ' 4/c f4 avev t4'c1-3d5- C +
�oP v ' Ai t,...ziticitA Act rec./ 5'
ketion A
mairip7i
�af
Ventilation Quantity /
(Determent quantity by using N1104.2 or Equation L1.1)Squarefeet
(Conditioned area
Basement— or unfinished) including
s
Humber of bedrooms _
. a / U
Total regWradventlatl %
Continuous vent n .
1
o' 5
6
r d/3
Directions- Determine the total and continuous ventilation rate by either using Table Pi110t.2 or equation 11-1.
The table and equation are below.
Table N1104.2
Total end Continuous Verdrlation Rates ( n cfm)
Number of Bedrooms
1
2
3 -4
5
6
Conditioned space {il!
sq. ft.)
Total/
continuous
Total/
continuous
Total/
continuous
Total/
continuous
Total/
continuous
Total/
continuous
1000-1500
60/40
75/40
90/45
105/53
120/60
135/68
1501-2000
70/40
85/43
100/50
115/58
130/55
145/73
2001-2500
80/40
95/48
110/55
125/63
140/70
155/78
2501-3000
90/45
105/53
120/60
135/68
150/75
165/83
3001-3500
100/50
115/58
130/65
145/79
160/80
175/88
3501-4000
L10/55
. 125/63
140/70
155/78
170/85
185/93
4001-4500
�120/60
135/68
150/75
165/83
180/90
195/98
4501-5000
130/&5
145/73
160/80
175/88
190/95
205/103
5001-5500
140/70
155/78
170/85
185/93
200/100
215/108
5501-6000
150/75
165/83
180/90
195/98
210/105
225/113
Equation 11-1
(0.02 x square feet of conditioned space) 4 [15 x (number of bedrooms + 111 • Total ventilation rate (cfm)
Total ventilation — The mechanical ventilation system shell provide auffldent outdoor air to equal the total ventilation rate
average, for each one -hour period according to the above table or equation. For heat recovery ventilators (NW) and energy
recovery ventilators (ERV) the average hourly ventilation capacity must be determined in consideration of any reduction of
exhaust or out outdoor air intake, or both, for deftest or other equipment Cycling.
Contirntove ventilation -A minimum of 50 percent of the total ventilation rate, but not less than 4¢Sfm, shall be provided,
on s continuous rate average for each one -hour period. The portion of the mechanical ventilation system Intended to be
continuous may have automatic cycling controls providing the average flow rate for each hour Is mei
SKIM •
Vttntilat)on Mathad
pow lr►hdmesl $r+r! tt,t only]
Mao only
aorrad tnr►taataa Corinna=flan ming In do
adieneset,ttlel{]lestilem1uowryttutor)sNW
%Maw) -*aelude w Low most not
oestiaeaen,lRhnftry pane thin Stash
taw dip Nlthof
Combings hpWhy Inrlrrkeoo*/mow POI wood
COrrSgteelrt Vt010aon thin
ins - 17,00sr for method of eleretiaelae. beloved orexhauster*. 8drnaod vetdfletbee esteem are twice* WV or
ERWs. tamer the low and h*l m emregthe, Leman afiltor must be rquol to or sib Man the ragtthed
SIMilidat +OW sad hose that SQOhif MOW than the Metlnuaw rate. (Far Instance. Mahe lour rim is 40 efm, the ventNrNan fen
Mart net extend 00 a ny Manta* controls may trim the use ela larger fen oat Is operated a percentage a/firodr how,
Safi C
Van lister% Fan Schedule
Nuristan
tarn
Contkiwnis
1
Intermittent
c1 (l ey 1`
f Q.LfJ¢r. ire
,
loCK,,s(
Utz Vex,*
„ . 4o 'A jeue1
_
CA*.G
a I-1, Pew +
er- e v,e I X ?
S-e^.) G. 0:,e.,_
Directions - The YIMi1ugbn foe sc a Ns dW ale despite rMat the fan Is fon the location, (fin and whether It is used for
caMMuatet s Mtxnniteet siatfirelon. Thelon that is chars for continuous v taadan must be aqua! ba Ar peter that the
loam arrMM. and less then JOfltligreeter teen the senenae3utrote Per instance, (fthe law Osb40stow the coitbir ti
vrndlat askran+wast MKox toot 00 cfrn,) Aetonmeek camper ~yellow aurae use of lamer.fen that t, award a psrorMgee of
each ]low.
Medea 0
Ve tNatton Cantrell
Ibaerjkapreronend antral of the wound. awl rrrternnow et watllstleq
t/• ftr.w n � .,ra+.v� -�: Ai. .1Nrrrlocked W. Lt five
owe,- Aura. dte►r
0kt arm -Drenthe Oho ape/uetoe1 of On yendsttere spawn. Than shawl* ite aebeuetr.re *% jet plen reel ny.n vet ihtettiers to elegy
*PP elldiseee.tmnaarepareat. Retried freaks oho nrtaadrpwteaktaltiry w4crMt►OtsaadproperODamlimWeebriltes4
wsptlMtfen& gets rru t Jule ore medlar toddlep yeraf.tkw deerlbo tee *mean ant emean of any mead, trahmNra mod Itpen&
en EMfor Wig b to be Installed etane emit self be I wind rat NMIMromreclyd oedietwieetedwfes tM elrsenates euulrnnert,
eteeeeettaoMM mei ooraertke ses detelisdit the msnt beYwerbetatlsaen AMNItkrrs rem fretolliew lasetneem rrlrrk'r or
r maineed Me oymbolohltobelntelo edrdslltheeirIrendinp esurptreetferreaper oforotelt4 Steb biteralImeakilefmtleeMadeend
eknt►tbed.
Mahan E
' Make-up sir
Amin n td.L lnwl from wlele'ee"w"ra tom YaMal03,I.1I
'
ereesra11{dMmnUmeteeee s7myelape from Min sew'
'
'
ttllreldslotra edmeldram paimrmeed born Imps male 6a1.t
bllerr ehealbe
latatIOn ofdud or system vsntdrtlan telska-up An oe■seerr,d eraw ails-op.ir aping dale _ �r
j on i t seer sed pot pound. t,c*inp r, trait iPil4
CNR ere not retsrlbrtdi
IlLidennelbseMpbrptombelWallarISILdoot
!age 2 of 6
Directions - in order to determine the makeup air, table 501.3.1 must be filled out (see below). For most new installation$ column
A will be appropriate, however, if atmospherically vented appliances of solid fuel appliances are installed, use the appropriate
column. For exhdng dwellings, see WC 501.3.3. Please ante, if the makeup air quantity is negative, no additional makeup ow will
be required far ventilation, if the value is positive refer to Table 501.3,2 and sire the opening. Transfer the cfm, site of opening and
type (round rectangular, flex or ripld) to the last line of section 0. The make-up air supply must be installed per MC 501.3.23.
Ta b)e 501.3.1
PROCEDURE TO DETERMINE MAKEUP MR QUANITY FOR EXHAUST EQUIPMENT IN DWELLINGS
(Additional combustion air will be rre9oired for combustion appSanas, see KAM method for cakubtlons)
One or multiple power
vent or direct vent
appliances or no
combustionappilarces
Column A
One at multiple fan-
assisted appliances and
power vent or direct vent
appliences
Column a
One atmospherically vent
gas or oil appliance or
one solid fuel appliance
Column C
Multiple atmoaphemcalla
vented gas or oil
appliances or solid fuel
appiacces
Column O
a) pressure factor
ldm/alj
0.15
0.09
0.06
OM
b) conditioned floor area le l Gncludln4
unPnished basements))
5'cii 8
Estimated Mouse Inlgtration tcrink i1a
alb)
L Eafawt t apadty
a) continuous wham -only ventilation
system Imtrl, (not applicable to
balanced van taatlen systems such as
HR/
b) dachas dryer kind
135
135
135
135
c) Io%dialect ealuuaming (dm);
Kitchen hood twitally
trial applkabie N recirculating system
or if powered meke►p air is electrically
inewtocied and match to exhaust)
6)
d) ID% of nest Wiest exharast rating
(efm), bath fan typically
(not applicable If recirculating system
or It powered malowe air Is eletlrfWly
rnt®Iaekad and matched towhee/II
Not
Applicable
Total Et hauet Capacity (dm);3
(Za+2b �2c+24I
7 r
S
3. Makeup Alt Quantity (cfm)
a) total exhaust capacity (from above)
3 S,
b) estimated Musa rrr(Itredon (froin
above'
c
41
Makeup au ONantlty lank
13a-3b)
(if value It negative, no maim* ur Is
needed)
4. For makeup Aar Opening Inky, refer
to Table S01,4.2
A. use this column if there we other than fan•aaaistad or atmospherically vented gas or ell appiance a If there We no combustion eppliancas (Power vent and
direct vent appliances may be used.)
S. Use this column Weave is one tan -assisted appliance per venting system_ (Appliances ether than atmospherically vented appliances may also be included.)
C. Use this column If there b one atmospberraly vented (other than fan -assisted) gas or oil appliance per venting system or one solid fuel appliance.
fs Use this column, Other* are muAtipre vtmaspherlaleyvenom gas et on, apoRances using a common vent our if there are atmosphareehyvented gas or all
applenss and solid fuel appliances.
S:\FormaWentMakupCnrnbAl rCals041S11.docs
Page 3of6
Makeup Air Opening Table for New and Existing Ovrellina
Table S013.2
On: or multiple power
rent. direct rent
appliances, or no
combustion appliances
Column A
One or muldpk fan-
assisted appliances and
pwrerwnt or direct
vent appliances
Column b
One atmoaphenrally
vented ps or oil
appliance or one solid
fuel appliance
Column C
Muidpie rtmotphertcaiy
vented gas of oil
appliances or solid fuel
0ppliaKea
Column 0
Oust diameter
Passive opening
1-36
I-22
1-15
1-9
3
Passive opening
37-56
23-41
16-28
10-17
4
Paseiva opening
57 - 309
41-66
29-46
18 - 251
3
Passive opening
110.163
67-100
47-69
29-42
6
Passive opening
164-232
101-143
70-99
43-61
7
Missive opening
233-317
144-195
100-135
62-33
r a
Pensive openhe
we/motorized damper
318-419
196-258
136-179
84-110
9
Passive opening
wfmotorized damper
420- 539
259- 332
leD-230
t11-141
10
Passive opening
es/motorized damper
540-679
333-419
231-390
143-179
11
Powered inikeup ale
, >679
1/419
a290
1.379
NA
Nobel:
A. An equivalent length of 100 feat of round smooth metal duct is assumed. subtract 40 feet for the exterior hood and ten feet for each 90- degree elbow to
determine the remaining $enstb of straight duct allowable.
8. ff flexible duct Is used. Increase the duct diameter by one inch. Flexible duct shall be stretched with minimal sass. Compressed duct shalt not be accepted.
C. Barometric dampers are prohibited In passive makeup air openplgs when any atmospherically vented appliance isinstased.
D. Powered makeup sir than be electrindly interbcked with the tartest exhaust system.
Section F
Combustion air
Not required per mechanical code ftio atmospheric or power vented appliances)
>.).
Passive lime EGC Appendix E, Worksheet E•1) slza and time 1
b
a f
r! ex
Other, describe:
Explanotiian - If no otrnospheric orPower vented oppHances are installed, check the appropriate bold, nut required ►f apower
vented or atmospherically vented appliance installed, use IFGC Appendix E, Worksheet E-.1 (see below). Please enter sire and type.
Combustion air vent supplies must cprnmunkatr with the opplrmme or appliances that require the combustion air.
Section F calculations follow an the next 2 pages.
G:irons\YentMakuKeenbAtrCats041511docx
Pagt4ofb
Directions - The Minnesota Fuel Gas Code method to cakulote to sire of a required combustion air opening, it called the Known Air
Inf Itration Rote Method. For new contraction, 4b of step 4 Is required to be Need out
WGC Apperadb E. WorksheetE-1
ResIdentlal Combustion Ale calculation Method
Or Furnace, Bailer. and/or Water Reuter In the Sane Space)
)
Soap 1: Complete Vented coot don appliance Information.
Fwrace/Boder:
_Draft Hood _FanAssisted lhout: /000 9twihr
,)eDirettVent
a Power Vent
Water Heater.
Draft Mood X Fan Assisted _ Direct Vent Input: 73 etii/hr
or Power Vent
Slip 2: Calculate the volume of tree Combustion Appliance Space (CAS) containing combustion appMances.
The CAS includes all spaces connected to one another by code compliant openings. CAS volume: / A 38
Its
LaWxK 1. W H
Step 3: Determine Air Changes per Hoot (AC301
Default ACM values have been incorporated into Table E•1 for use with Method alb (KAIR Method).
If the year of construction or ACH Is not known, use method 4a Iienderd Method).
Slap 4: Determine Requited Volume he Combustion Air. 100 NOT COUNT DIRECTVENT APPLIANCES)
Is. Stendard Method
Total Btu/hrinput of all combustion appIances Input: Btu/hr
Use Standard Method Column le Table E-1 to Find Total Rewired TRV: h°
Volume (TRY)
If CAS Volume (from Step 2) fs greater IMiu TRV then no outdoor openings art needed.
If CAS Volume (from Step 2) b bras than TRY then go to STEP S.
ice. Knower Air MMdtratian Rate (KAIRI Method (DO NOT COUNT DIRECT VENT APPLI NCE
Total BtuAir Input of all f iuWad and power went appliances Input�% 0 Btu%Ihr
/
Use fan•Aaistad Appliances column in Table E-1 to find RVFA: 56 S^ fta
Required Volume Fan Alamo (tl1IFA1
Total 8tu/hr input of all Natural draft appllsncen Input: Btu/hr
Use Natural draft Ayfilancescolumn in Table E-1 to Ind RVNFA: ft`
tlequired Volum. Maturd draftappgances (RVNDAI /
Total Required Volume (TRY) = RVFA - RVNOA UV* ,"5 P d r J S 6 0 S TRY ft'
If GAS Volume (from Step 2) is ereate:Ibis TRV then no outdoor openings are needed.
it CAS Volume (from Step Vs Ira Nan TRV then to to STEPS.
Step Si Calculate the redo of ern table Interior volume to the total required volume.
Ratio = CAS Valunw tfrhan Stap 2) hlikte / iyTRV (from Step 4a or Step ab) Ratio ; 16 38 S'Ga S' . a
!Mp e: Caieulata R.ductiion Factor (RP).
IF■linker Rade RF=1-''if? / 7 /
Shp 7; Calculate single outdoor opening as if al combustion air is from outside.
Total staler input of all CanixistIon Appaeeces Mn the same Cis Input ` Y. 000 ate/hr
(EXCEPT DIRECT VENT)
Combs ton Air Opening Asa (CAOA): ..., , 2 (—
Total BGi/hr ditnSlee ay 3000 Btu/hr par in' CAOA J "CC° / 3000 Muth, fief Ina OJ ire
Nap I: Calculate Mnimum(AOA. `
Mi'7 73�
nbrOA umCA=CAOAmuldpiadDerip Minimum c2 a�a / 7/ • l In'
Beep 9: Calculate Combustion Air Opening Diameter (care)
CA00 a 1.13 nwApged by the anon root of Minimum CAOA CA00 =1.13 >t Mlntmum CAOA = ' a2 in. ammeter
go up one inch In sloe if using flex dud
1 Waited, ACH Can be determined using ASHRAE calatstian or flower dour test. Fohw procedures in Sabin
DIM.
G;iformaWent MkupCombAirCeka4lSsi.deco
Page 5 ot'6
IF6C Appendix E, Table E-1
Residential Commbustlon air (Required Interior Volume Based on Input Rating of Appliance}
Input Rating
(8tu/hr)
Standard Method 1
Known Air Infiltration Rate jKAIRj Method (cu ft)
Fan Assisted or Power vent
Natural Draft
1994 to present
Pre-1994
1994 to present Pre-1994
5,000
250
375
188
525 263
10,000
500
750
375
1,050 525
15,000
750
1,125
563
1,575 788
212,000
1,000
1.500
750
2,100 1,050
25,000
1,250
1,875
938
2,625 1,313
30,000
1,500
2,250
1,125
3.150 1,575
35,00D
1,750
2,625
1,313
3,675 1,838
40,000
2,000
3,000
1,500 ,
4,200 2,100
45,000
2,250
3,375
1x6$8
4,725 2.363
50,000
2,500
3,750
1,675
5,250 2,625
55,000
2,750
4,125
2,061
5,775 2,888
60,000
-
5,000
4,500
2,250
6,300 3450
65,000
3,250
4,875
2,433
6,825 3,413
70,000
3,500
5,250
2,625
7,350 3,675
75,000
3,750
5,625
2,813
7,875
34.938
80,000
4,000
• 6,000
3,000
8,400
4,200
85,000
4,250
6,375
3,188
8,925
4,463
90,000
4,500
6,750
3,375
9.450
4,725
95,000
4,750
7125
3,563
9,975
4,988
100,000
5,000
7,500
3,750
10,500
5,250
105,000
5.250
7,875
3.938
11,025
5,513
110,000
5500
8,250
4,125
11,550
5,775
115,000
5,750
8.625
4,313
12,075
6,038
120,000
6,000
9,000
4,500
12,600
6,300
125,000
6,250
9,375
4,688
13,125
6,563
130.000
6,500
9,750
4,875
13,650
6,825
131,000
6,750
10,125
5,069
14,175
7,088
140,000
7,000
10,500
5,250
14,700
7,350
145,000
7,250
10,875
5,433
15,225
7,613
150000
7,500
�...4,50
5,625
15,750
7,875
155,000
7,750
11,625
5,813
16,275
8,191
160,000
8,000
12,000
6,000
16200
8,400
165,000
6.250
12,375
6,138
17,325
3,663
170,000
8,500
12,750
6,375
17,350
6,925
175,000
8,750
13,125
6563
18,375
9,188
140.000
9,000
13,500
6.750
18,900
9,450
185,000
9.250
13,875
19,425
9,713
190,000
9 500
14,250
_,938
7,125
19,950
9,975
195,000
5.750
14,625
7,313
20,475
10,238
200,000
10.000
15,000
7,500
21,000 '
10,500
205,000
10,250
15,375
7 688
21,525
10,783
210,000
10,500
15,750
7,875
22,050
11,025
215,000
10,750
16,125
8,063
22,575
11,2811
220, 000
11,000
16.500
8.250
23,100
11,550
225,000
11,250
16,875
8,431
23,625
11,813
2.10,000
11,500
17,250
8,625
24,150
12,075
1. The 1994 date refers to dwsifeyls constructed untie the 3994 Minnesota Fnerey Cade. The default KAIR used in the section of the table is
0.10 ACM.
2. This testier of the table is to ex used for dwellings constructed prior to 1994 lice default K,AIR used in chit mien of Oa table s0.40 ACFI
6:VotrnewlettMa&. tamhAtrCals042511-done
Page 6 of 6
EAGAN
3830 PILOT KNOB ROAD I EAGAN, MN 55122-1810
(651) 675-5300 1 waterresacityofeagan.com MAY 0 5 2021
For Office Use
Stormwater Management Permit #:
!1.O0z3
Building Permit #: 1 00 I b
Escrow Deposit: 3) 00 0
Staff:
L
STORMWATER MANAGEMENT PERMIT
Date: 5-5-2021 Site Address: 4002 Haven Woods Court
Description of Project: New Construction
Area of Land Being Disturbed: 1 0,282/sqft Start Date: 5-17-2021
Completion Date:
5-17-2022
❑ Please submit a Land Disturbance and Stormwater Pollution Prevention Plan with this application.
Property Owner
Contractor
Name: SD Companies Phone: 651-994-3997
Address / City / Zip:
Contact:
750 Main Street, Suite 223
Sean Doyle
Email:
Applicant is: Owner Contractor
sean@sd-customhomes.com
Name: SD Custom Homes License#: BC637953
Address: 750 Main Street City: Mendota Heights
State: MN
Contact:
Zip: 55118 Phone: 651-994-3997
Sean Doyle
Email: sean@sd-customhomes.com
Erosion and Sediment Control Performance Security
The City requires an escrow deposit to secure performance of erosion and sediment control (ESC) requirements, including proper
installation and maintenance. The security shall pay for any City costs or expenses to bring the site into compliance with the
stormwater management permit, including any engineering, legal, or administrative expenses; inspections; and necessary work by
City contractor(s). The City may extract from the security escrow. The escrow deposit will be released only upon inspection and
written notice of conformance by the City.
The following escrow deposits include two (2) required City inspections, initial and final.
Existing Single -Family Residential Lot (addition, demolition, pool, retaining wall, etc.)
New Single -Family Construction
Multi -Family or Commercial Construction (new, addition, demolition)
*Maximum of $12,000
Erosion and Sediment Control Reinspection Fee (for as needed City reinspections after the two (2) included) $85/trip
$1,000/lot
$3,000/lot
$5,000/acre*
Security Amount: $3,000.00
The applicant assumes all responsibilities for installation and maintenance of pollution prevention practices on this site
Any violations of City Code identified by the City shall be addressed within 48-hours of service of the notification.
The applicant understands that failure to maintain pollution prevention practices within the time allotted by the City
notification, will result in enforcement action to correct site deficiencies that are in violation of Sec. 4.34.
The issuance of this permit constitutes a right -of -entry of the City or its contractors to enter upon the construction site for
the purpose of completing ordinance enforcement and/or completing corrective work.
I hereby acknowledge that this information is complete and accurate; that the work will be in conformance with the
ordinances and codes of the City of Eagan; that I understand this is not a permit, but only an application for a permit, and
work is not to start without a permit; that the work will be in accordance with the approved plan in the case of work which
requires a review and approval of plans.
The undersigned accepts full responsibility for compliance with the Stormwater Management Ordinance of the City of
Eagan and agrees to comply with the Stormwater Pollution Prevention Plan or equivalent in full.
Sean Doyle
X
c.5eao. Z7
licant's Si ature
Applicant's Printed Name App
g
Performance Security Release
The following information will determine to whom the escrow deposit will be returned. Security will be returned in the form
of a check.
Name: SD Custom Homes
Address /city /zip: 750 Main Street Suite 223, Mendota Heights MN 55118
Phone: 651-994-3997 Email: sean@sd-customhomes.com
Amount:
Permit Number:
FOR OFFICE USE ONLY
SUB TYPE
X Stormwater Management Permit
DESCRIPTION
Addition
New
REQUIRED INSPECTIONS
_ Initial Inspection
Final Inspection
SECURITY
Demolition
Retaining Wall
WORK TYPE
Apartments Commercial/Industrial
Multi Family Public Facility
Single Family
- Pool
Other:
Erosion and Sediment Control Deposit °(6501 2257) $3"000
Other:
Total: $3,000
Reviewed By: Dnan Leyendecker Water Resources
Date: 51512021
PERMIT
City of Eagan Permit Type:Building
Permit Number:EA174293
Date Issued:01/14/2022
Permit Category:ePermit
Site Address: 4002 Haven Woods Ct
Lot:2 Block: 1 Addition: Haven Woods
PID:10-32090-01-020
Use:
Description:
Sub Type:Fireplace
Work Type:Gas Fireplace (new)
Description:
Census Code:434 - Residential Additions, Alterations
Zoning:
Square Feet:0
Occupancy:
Construction Type:
Comments:Improvements to the home may require smoke detectors in all bedrooms. Chimney / flue must be inspected prior to
concealing.
Carbon monoxide detectors are required within 10 feet of all sleeping room openings in residential homes (Minnesota State
Valuation: 3,000.00
Fee Summary:BL - Base Fee $3K $88.50 0801.4085
Surcharge - Based on Valuation $3K $1.50 9001.2195
$90.00 Total:
I hereby acknowledge that I have read this application and state that the information is correct and agree to comply with all applicable State
of Minnesota Statutes and City of Eagan Ordinances.
Contractor:Owner:- Applicant -
Sd Companies Llc
750 Main St Ste 223
Mendota Heights MN 55118
Glowing Hearth And Home Llc
100 Eldorado Dr.
Jordan MN 55352
(952) 492-9276
Applicant/Permitee: Signature Issued By: Signature
a � �
EAGAN
ESTABLISHED 1860
June 22, 2022
Site Meeting Minutes
Havenwoods Development
4002 Havenwoods
3998 HAvenwoods
Block 1 lots 1 & 2
A site meeting was conducted by myself, Nick Wilson, and Brain McMahon.
Block 1 lot 2 has been graded per the approved grading plan, Block 1 lot 1 will need to have fill brought
in to make it match the grade from lot 2. There is a EOF located on lot 1. A retaining wall will need to
be established on lot 1 to the South of the EOF. The retaining wall will need to be in between the house
and the EOF. Brian McMahon stated the retaining wall will be worked out between the builder, to be
determined, and Brian McMahon, per conversation with Brian McMahon.
Thanks,
Miles Johnson
Chief Building Official
MAYOR I MIKE MAGUIRE COUNCIL MEMBERS I PAUL BAKKEN, CYNDEE FIELDS, GARY HANSEN, MIKE SUPINA CITYOFEAGAN.COM
CITY ADMINISTRATOR I DAVID M. OSBERG MUNICIPAL CENTER 13830 PILOT KNOB ROAD, EAGAN, MN 55122-1810
MAIN: (651) 675-5000 MAINTENANCE: (651) 675-5300 UTILITIES: (651) 675-5200
IF YOU HAVE A HEARING OR SPEECH DISABILITY, CONTACT US AT `6S1) 675-5000 THROUGH YOUR PREFERRED TELECOMMUNICATIONS RELAY SERVICE.