2020 Silver Bell Rd - Blackstone Fitness Test & Balance Report 2021-10-25remier TEST & BALANCE INC 375 230th Ave, Somerset WI 54025 - Phone: (612) 834-0311 Fax: (414) 377-3349 www.Premierbalancing.com TESTING, ADJUSTING AND BALANCING BUREAU THE PROFESSIONAL'S CHOICE" Testing, Adjusting & Balancing Report TABB TECHNICIAN Technician: Tony Kompelien Cell Phone: 612-419-1425 Email Address: tony@premierbalancing.com PROJECT Blackstone Fitness Silver Bell Business Center 2020 Silver Bell Road, Suite 4 Eagan, MN 55122 CLIENT Kraft Contracting & Mechanical, LLC 2415 Ventura Drive, #100 Woodbury, MN 55125 ENGINEER NA Report Date October 25, 2021 TABB CERTIFICATION TABB certification of a Supervisor is TABB's statement that the Supervisor is able to supervise testing, adjusting and balancing of building environmental systems to produce the design objectives or optimum system performance. For TABB Certification purposes, a Supervisor is the person who, while employed by a TABB Certified Contractor, is responsible and accountable for overseeing, coordinating and ensuring that projects are performed by TABB Certified Technicians in accordance with TABB standards (including the ICB Code of Conduct and the TAB General Rules). Measurements recorded in this report are in accordance with the SMACNA I TABB HVAC Systems, Testing, Adjusting and Balancing manual. Anthony Kompelien TABB Technician 1E875224T December 31, 2022 eru,cmfor 27r2 0. Premier Test & Balance LLC Peter Korzenowski TB0458712C lIgt Valid Unless Sig Anthony Kompelien Premier Test & Balance LLC TARE Supervisor TH8752295 December 31, 2022 erzncea 10/27/2020 TABB Certified "The Professional's Choice" Page 2 TABS QUALITY ASSURANCE PROGRAM BACKGROUND TABB seeks to ensure the integrity of its certification program by: (a) setting eligibility criteria for TABB Certified Supervisors and TABB Certified Contractors, (b) establishing testing procedures for TABB Certified Supervisors, (c) requiring continuing education and continuous compliance with eligibility criteria for renewal of certification, and (d) periodically reviewing its recognition of technician certification. High quality work on the part of TABB Certified Technicians and TABB Certified Supervisors and TABB Certified Contractors (TABB Professionals) is essential to integrity of the TABB Certification Program. TABB offers this TABB Quality Assurance Program to help assure high quality work. By accepting TABB qualification or certification, every TABB Professional accepts the responsibilities or this Program. Quality Assurance Every customer of a TABB Certified Contractor shall be entitled to expect: (1) that testing, adjusting and balancing work by the contractor and its TABB Professionals will meet TABB standards; (2) that testing, adjusting and balancing reports provided to the customer will have been prepared by a TABB Certified Technician, and reviewed by a TABB Certified Supervisor; and (3) that the report(s) will include measurements taken accurately with the date and mode of operation of the systems. TABB 8403 Arlington Boulevard Fairfax, VA 22031 Phone - (703) 299-5646 Fax - (703) 683-7615 TABB Certified "The Professional's Choice" Page 3 INSTRUMENT CALIBRATION REPORT INSTRUMENT MODEL MANUFACTURER SERIAL NUMBER CALIBRATION DATES Current Expiration Rotating Measuring Instrument PLT-5000 Check -Line B15985012P 10/05/21 10/05/22 Temperature Measuring Instrument Temperature Measuring Probe HM70 HMP75 Vaisala Vaisala M4820017 M5040569 10/08/21 10/08/21 10/08/22 10/08/22 Electrical Measuring Instruments 117 322 Fluke Fluke 18561871 17830473 10/05/21 10/05/21 10/05/22 10/05/22 Air Pressure Measuring Instrument S-PVF-1 Evergreen Telemetry 1800207 09/02/21 09/02/22 Air Velocity Measuring Instrument S-PVF-1 Evergreen Telemetry 1800207 09/02/21 09/02/22 Hydronic Pressure Measuring Instrument 0 to 300 psi HM-675 Alnor 71514005 10/05/21 10/05/22 TABB Certified "The Professional's Choice" Page 4 Premier Test & Balance Index Project: Technician: Blackstone Fitness Tony Kompelien Premier Job Number: 4232 Report Date: 10/25/21 Page System I Equipment Description Completion Date 6-7 RTU-A (East) Constant Air Volume 10/25/21 8-9 RTU-B (West) Constant Air Volume 10/25/21 10 Existing Exhaust Constant Air Volume 10/25/21 TABB Certified "The Professional's Choice" Page 5 Premier Test & Balance Air Handling Unit Test Data Project: System: Technician: Blackstone Fitness RTU-A (East) Tony Kompelien Premier Job Number: 4232 Completion Date: 10/25/21 System Scheduled Data Model number: 581KPO5N110A2A0AAA Manufacturer: Bryant Total Design CFM: - Fan Static Pressure: - Serial number: 2121052834 Outlet Total CFM: 1,625 Min.Outside Air CFM: 439 Equipment Location: Roof Performance Data Description Motor HP: Motor RPM: Motor Hertz: Motor Service Factor: Motor Phase: Motor Voltage: Motor Amperage: Motor BHP: Fan RPM: Scheduled I Submittal Data 0.75 1750 60.0 1.15 1 208 7.1 - 1750 Actual Field Measurements 0.75 1750 60.0 1.15 1 213 5.7 0.62 Direct Drive Static Pressure Data Component Static Pressure inches of water) Pressure Rise 1 Drop Pressure Total (inches) In Out RTU ESP: -0.13 0.39 Rise 0.52 Airflow Measurements Supply Air Opening No. Area Served Size K Factor Design Final Reading Preliminary Reading Velocity CFM Velocity CFM % Velocity CFM 1 Various Flow Hood 1.00 1625 1625 1613 1613 99% 1631 1631 Total 1625 1613 99% 1631 Minimum Outside Air Size K Factor Design Final Reading Preliminary Reading Velocity CFM Velocity CFM % Velocity CFM Total 29x16 3.22 136 439 139 448 102% 43 139 Remarks: a) Fitness measured square footage: 1817 Sq. Ft. (.3 OA CFM per Sq. Ft.) = 545 OA CFM total required. (25.7% outside air needed to meet required CFM - Unit was set to 27% outside air). b) The sum of the outlets used for fan total CFM. TABB Certified "The Professional's Choice" Page 6 Premier Test & Balance Air Outlet Test Report Project: System: Technician: Blackstone Fitness RTU-A (East) Tony Kompelien Premier Job Number: 4232 Completion Date: 10/25/21 Airflow Measurements Opening Area Size K Design Final Reading Preliminary Reading No. Served Factor Velocity CFM Velocity CFM % Velocity CFM 1 Fitness Flow Hood 1.00 325 325 332 332 102% 396 396 2 Fitness Flow Hood 1.00 325 325 317 317 98% 265 265 3 Fitness Flow Hood 1.00 325 325 312 312 96% 493 493 4 Fitness Flow Hood 1.00 325 325 345 345 106% 179 179 5 Fitness Flow Hood 1.00 325 325 308 308 95% 298 298 Total 1625 1613 99% 1631 Remarks: a) b) c) d) e) TABB Certified "The Professional's Choice" Page 7 Premier Test & Balance Air Handling Unit Test Data Project: System: Technician: Blackstone Fitness RTU-B (West) Tony Kompelien Premier Job Number: 4232 Completion Date: 10/25/21 System Scheduled Data Model number: 580FPV036074ABGA Manufacturer: Bryant Total Design CFM: - Fan Static Pressure: - Serial number: 0407G20151 Outlet Total CFM: 1,145 Min.Outside Air CFM: 309 Equipment Location: Roof Performance Data Description Motor HP: Motor RPM: Motor Hertz: Motor Service Factor: Motor Phase: Motor Voltage: Motor Amperage: Motor BHP: Fan RPM: Scheduled I Submittal Data 0.50 1620 60.0 1.15 1 208 4.9 - - Actual Field Measurements 0.50 1620 60.0 1.15 1 213 4.2 0.44 836 Static Pressure Data Component Static Pressure inches of water) Pressure Rise 1 Drop Pressure Total (inches) In Out RTU ESP: -0.14 0.34 Rise 0.48 Airflow Measurements Supply Air Opening No. Area Served Size K Factor Design Final Reading Preliminary Reading Velocity CFM Velocity CFM % Velocity CFM 1 Various Flow Hood 1.00 1145 1145 1143 1143 100% 1058 1058 Total 1145 1143 100% 1058 Minimum Outside Air Size K Factor Design Final Reading Preliminary Reading Velocity CFM Velocity CFM % Velocity CFM Total 24x14 2.33 132 309 130 303 98% 54 126 Remarks: a) Fitness measured square footage: 1817 Sq. Ft. (.3 OA CFM per Sq. Ft.) = 545 OA CFM total required. (25.7% outside air needed to meet required CFM - Unit was set to 27% outside air). b) The sum of the outlets used for fan total CFM. TABB Certified "The Professional's Choice" Page 8 Premier Test & Balance Air Outlet Test Report Project: System: Technician: Blackstone Fitness RTU-B (West) Tony Kompelien Premier Job Number: 4232 Completion Date: 10/25/21 Airflow Measurements Opening Area Size K Design Final Reading Preliminary Reading No. Served Factor Velocity CFM Velocity CFM % Velocity CFM 1 Womens Bathroom Flow Hood 1.00 45 45 47 47 105% 44 44 2 Office Flow Hood 1.00 90 90 93 93 103% 86 86 3 Corner Office Flow Hood 1.00 110 110 100 100 91% 116 116 4 Corner Office Flow Hood 1.00 100 100 101 101 101% 98 98 5 Front Entry Area Flow Hood 1.00 100 100 92 92 92% 20 20 6 Front Entry Area Flow Hood 1.00 100 100 104 104 104% 99 99 7 Front Entry Area Flow Hood 1.00 100 100 95 95 95% 88 88 8 Fitness Flow Hood 1.00 200 200 219 219 110% 202 202 9 Fitness Flow Hood 1.00 300 300 292 292 97% 305 305 Total 1145 1143 100% 1058 Remarks: a) b) c) d) e) TABB Certified "The Professional's Choice" Page 9 Premier Test & Balance Air Outlet Test Report Project: System: Technician: Blackstone Fitness Existing Exhaust Tony Kompelien Premier Job Number: 4232 Completion Date: 10/25/21 Airflow Measurements Opening No. Area Served Size K Factor Design Final Reading Preliminary Reading Velocity CFM Velocity CFM % Velocity CFM 1 2 3 Shower Mens Bathroom Wormens Bathroom Flow Hood Flow Hood Flow Hood 1.00 1.00 1.00 150 100 100 150 100 100 156 98 95 156 98 95 104% 98% 95% 153 116 82 153 116 82 Total 350 349 100% 351 Remarks: a) b) c) d) e) TABB Certified "The Professional's Choice" Page 10