Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
4828 Avery Court
020 Aveml. Lot- 2, BIocP 1 l Y Q o z ❑✓ ❑ O ❑ ❑✓ ❑ ❑✓ ❑ O ❑ El �l�i'aa� C✓I ❑ O ❑ O ❑ ❑❑©❑©❑❑❑❑❑❑❑ Add/Change ❑ 0 ❑ ❑ 0 ❑ ❑ 0 ❑ O ❑ ❑ O ❑ ❑ 0 ❑ ❑ ❑ 0 ❑ go o ❑ 0. ❑ 0 Yes ❑ 0 ❑ ❑ 0 ❑ ❑ ❑✓ ❑ ❑ ❑✓ ❑ ❑ 00 No INo PROPERTY LEGAL: LOT SURVEY( CHECKLIST FOR RESIDENTIAL BUILDING PERMIT APPLICATION Lots 1, 2, 3, 4, & 5, Block 11, Avery Pines DATE OF SURVEY: 9/23/21 LATEST REVISION: ///// f DOCUMENT STANDARDS • Registered Land Surveyor signature and company • Building Permit Applicant • Legal description • Address • North arrow and scale • House type (rambler, walkout, split w/o, split entry, lookout, etc.) • Directional drainage arrows with slope/gradient % • Proposed/existing sewer and water services & invert elevation • Street name • Driveway (grade & width - in R/W and back of curb, 22' max.) • Lot Square Footage • Lot Coverage ELEVATIONS Existing • Property corners • Top of curb at the driveway and property line extensions • Elevations of any existing adjacent homes • Adequate footing depth of structures due to adjacent utility trenches • Waterways (pond, stream, etc.) Proposed • Garage floor • Basement floor • Lowest exposed elevation (walkout/window) • Property corners • Front and rear of home at the foundation • PRV Required PONDING AREA (if applicable) • Easement line • NWL • HWL • Pond # designation • Emergency Overflow Elevation • Pond/Wetland buffer delineation • Shoreland Zoning Overlay District • Conservation Easements DIMENSIONS • Lot lines/Bearings & dimensions • Right-of-way and street width (to back of curb) • Proposed home dimensions including any proposed decks, overhangs greater than 2', porches, etc. (i.e. all structures requiring permanent footings) • Show all easements of record and any City utilities within those easements • Setbacks of proposed structure and sideyard setback of adjacent existing structures • Retaining wall requirements: Reviewed By: Dave Westermayer Date 11/1/21 AN G:/1 Engineering/Forms/Cert. of Survey Checklist Fillable 03-16-2021 L.bt a dolt II 4sze -Avg Ct- 1-7.2 -7s$ Slope 3 Lot 1 Lot area = 2407 SF House area = 1330 SF Porch area = 22 SF Sidewalk area = 46 SF Driveway area = 91 SF Patio area = 82 SF Total Impervious Area = 1571 SF Impervious Coverage = 65.3% 3:1 Maximum � Al l all W �u,/ or ry*i nirzgCONTROL € mired ialtr‘rik II II _ I I / Lot 2 Lot area = 2004 SF House area = 1233 SF Porch area = 22 SF Sidewalk area = 46 SF Driveway area = 121 SF Patio area = 83 SF Total Impervious Area = 1505 SF Impervious Coverage = 75.1% Lot 3 Lot area = 2004 SF House area = 1232 SF Porch area = 22 SF Sidewalk area = 46 SF Driveway area = 91 SF Patio area = 83 SF Total Impervious Area = 1474 SF Impervious Coverage = 73.6% Lot 4 Lot area = 2004 SF L = _ - House area = 1337 SF \\ Porch area = 22 SF Sidewalk area = 46 SF Driveway area = 121 SF Patio area = 82 SF Total Impervious Area = 1608 SF Impervious Coverage = 80.2% // I I/ T II I I A I I 1 /II 1 BB B chmark t--r-24.0 ' i•43.182 / Ben¢hmar/C I II I I i;1 II I I Lot 5 Lot area = 2407 SF House area = 1226 SF Porch area = 22 SF Sidewalk area = 49 SF Driveway area = 152 SF Patio area = 83 SF Total Impervious Area = 1532 SF Impervious Coverage = 63.6% 943 74 Ben hmark I I II B nchmarl4 Construction Notes: 1. Install rock construction entrance. 2. Install silt fence as needed for erosion control. 3. Sidewalks shall drain away from house a minimum of 1.0%. 4. Contractor must verify driveway design. 5. Contractor must verify service elevation prior to construction. 6. Add or remove foundation ledge as required. 7. Retaining walls are conditional; Wall installed if the grade exceeds 3:1. Wall will not be installed if the grade is 3:1 or less. X 943.2 (945.0 944.0 X 943.7 I I I I I I I I I I1 II *SITE UNDER CONSTRUCTION* curb and utilities shown are proposed S87°04'10"E X 944.0 0 14.50 !_ (944.8) �a N87°0410"W • Denotes iron pipe service ▪ Denotes television box 111 Denotes electric box ❑� Denotes telephone box X 000.00 Denotes existing elevation ( 000.00 ) Denotes proposed elevation Denotes drainage flow direction • Denotes spike • Denotes proposed retaining wall designed and built by others. (944.3) x 943.9 ,*(s:p Denotes General Notes: 1. Grading plan by Pioneer last dated 7-7-21 was used to determine proposed elevations shown herein. 2. This survey does not purport to show improvements or encroachments, except as shown, as surveyed by me or under my direct supervision. 3. Proposed building dimensions shown are for horizontal location of structures on the lot only. Contact builder prior to construction for approved construction plans. 4. No specific soils investigation has been performed on this lot by the surveyor. The suitability of soils to support the specific house proposed is not the responsibility of the surveyor. 5. This certificate does not purport to show easements other than those shown on the recorded plat. 6. Bearings shown are based on an assumed datum. PIZNEERneenng, PA1 CIVIL ENGINEERS LAND PLANNERS LAND SURVEYORS LANDSCAPE ARCITTECTS 2422 Enterprise Drive Ph. : (651) 681-1914 Mendota Heights, MN 55120 Fax: (651) 681-9488 www.pioneereng.com Project # :121194000 (Folder #:85571Drawn by: CWIJ r Icy Daze 83.50 X 944.7 83.50 X 943.9 X 944.7 944.0 (942.5) X 942.8 I, O O M oo CO (NI 942.6X X 945.5 944.22 Benchmark X 944.5 944.05 Benchmark X 943.7 (D (D ai N 944.24 Benchmark X 943.0 943.15 Benchmark O ZO t) N O N X 942.4 943.16 Benchmark X 942.0 942.56 Benchmark X 941.4 P V House elevations (Proposed) / As -built Top Of Foundation Elev. :(946.2) / Garage Slab Elev. @ Door :(945,7) / EWED EAGAN ENGINEERING DEPT We hereby certify to Pulte Group that this survey, plan or report was prepared by me or under my direct supervision, and that I am a duly licensed Land Surveyor under the laws of the State of Minnesota, dated 09/23/21. BY: Signed: Pi gl Leer Erygineering, P.A. Peter J. Hawkinson, 'Professional Land Surveyor Minnesota License No. 42299 email-phawkinson©pioneereng.com Lots 1,2,3,4,5, Block 11, AVERY PINES according to the recorded plat thereof Dakota County, Minnesota Address: Avery Court, Eagan, Minnesota House Model: Bowman, Ashton, Bowman, Ashton, Bowman Elevation: EL1 Buyer: N/A 0' 10' 20' Scale: 1" = 20' Benchmark: Top Nut Hydrant Elevation = Revisions: 1.) 10-18-21 Stake house 2.) 11-01-21 City comments Certificate of Survey for: Pulte Group 7500 Flying Cloud Drive Ste 670 Eden Prairie, MN 55344 n Pinnoor 3830 PILOT KNOB ROAD I EAGAN, MN 55122-1810 (651) 675-5675 l FAX: (651) 675-5694 buildinainspections(citvofeaoan.com BL 172758 865b . 80 PL 172759 l o o • a$ ME 172760 too . ooiE AG N For office use SW 172761 I Permit #: 172758 Permit Fee: v gooJ (• w ' Date Received: 10/15/2021 PF Staff: Lo-f 2, 6)0(4_ 1I Ic ►vi j It 2021 RESIDENTIAL BUILDING PERMIT APPLICATION Date: 10/12/21 Site Address: 4828 Avery Court Unit#: 2 Resident/ Owner Name: Pulte Homes of MN Phone: 763-274-9345 7500 Flying Cloud Drive, Eden Prairie, MN 55344 Address / City / Zip: Applicant is: Owner ✓ Contractor Owner Email: brian.gergen@pultegroup.com Type of Work Description of work: New Residential Construction Construction Cost: 169,000 Multi -Family Building: (Yes X / No ) Contractor Company: Pulte Homes of MN Contact: Address: 7500 Flying Cloud Drive City: Eden Prairie State: MN Zip: 55344 Phone: Email: ellie.rogers@pultegroup.com License #: BC627723 Lead Certificate #: If the project is exempt from lead certification, please explain why: In the last 12 months, Yes ✓ No COMPLETE THIS AREA ONLY IF CONSTRUCTING A NEW BUILDING has the City of Eagan issued a permit for a similar plan based on a master plan? If yes, date and address of master plan: Licensed Plumber: Mechanical Contractor: Sewer & Water Contractor: Fire Suppression Contractor: Elander Phone: (763) 473-2267 Elander Phone: (763) 473-2267 Ground Tech Phone: (651) 964-0006 FSS Phone: 651-775-3964 NOTE: Plans and supporting documents that you submit are considered to be public information. Portions of the Information maybe classified as non-public if you provide specific reasons that would permit the City to conclude that they are trade secrets. You may subscribe to receive an electronic notification from the City of proposed ordinances by signing up for an email update on the City's website at www.cityofeagan.com/subscribe CALL BEFORE YOU DIG. Contact Gopher State One Call at (651) 454-0002 or www.aoaherstateonecall.orq for protection against underground utility damage. Contact Gopher State One Call 48 hours before you intend to dig to receive locates of underground utilities. I hereby acknowledge that this information is complete and accurate; that the work will be in conformance with the ordinances and codes of the City of Eagan; that I understand this is not a permit, but only an application for a permit, and work is not to start without a permit; that the work will be in accordance with the approved plan in the case of work which requires a review and approval of plans. )(Steve Brock Applicant's Printed Name Sim. 34.00,4 952 22-9-07f( x Applicant's Signature FOR OFFICE USE ONLY Site Address: 4828 Avery Ct Permit #: 172758 SUB TYPES Foundation — Fireplace _ Porch (3-Season) _ Miscellaneous Single Family _ Garage _ Porch (4-Season) _ Accessory Building Multi _ Deck _ Porch (Screen/Gazebo/Pergola) ✓ 01 of 5 Plex _ Lower Level _ Pool WORK TYPES ✓ New _ Repair _ Siding _ Retaining Wall Addition _ Fire Repair _ Reroof _ Move Building Alteration _ Water Damage _ Windows _ Demolish Building* Replace Egress Window _ Solar *Demolition of entire building — give PCA handout to applicant DESCRIPTION Calculated Valuation $199,125.45 Occupancy IRC-3 Townhouse Plan Review Code Edition (25%_ 100% ✓) Zoning Census Code IO ( Stories # of Units 5 Square Feet 1897 # of Buildings Length Fire Suppression Required 1/ 2020 MRC 2 MCES System ✓ SAC Units l Type of Construction Not Applicable Width City Water ✓ Booster Pump PRV j/ REQUIRED INSPECTIONS ✓ Footings (New Building) ✓ Meter Size: 3/4 Footings (Deck) ✓ Final / C.O. Required _ Footings (Addition) Final / No C.O. Required ✓ Foundation / Foundation Before Backfill HVAC _ Service Test Gas Line Air Test Hood Roof: _Ice & Water _Final Pool: _Footings _Air/Gas Tests _Final ✓ Framing 30 Minutes ✓ 1 Hour Drain Tile ✓ Fireplace: ✓ Rough In ✓ Air Test ✓ Final Siding: _Stucco Lath _Stone Lath _Brick EFIS ✓ Insulation Windows ✓ Sheathing Retaining Wall: _ Footings _ Backfill _ Final ✓ Sheetrock ✓ Radon Control ✓ Fire Walls Fire Suppression: ✓Rough InVFinal ✓ Braced Walls JL Erosion Control Stormwater Management Shower Pan Other: Permit Required: Reviewed By: , Building Inspector RESIDENTIAL FEES Calculated Valuation $ 199,125.45 Base Fee Plan Review State Surcharge MCES SAC City SAC Utility Connection Charge S&W Permit & Surcharge Treatment Plant Radio Read Other: 3/4" Meter Copies: $ 1,656.75 $ 1,076.89 $ 99.56 $ 2,485.00 $ 122.10 $ 1,592.90 $ 129.00 $ 989.60 $ 205.00 $ 300.00 TOTAL $ 8,656.80 Residential Permit Valuation Calculations Site Address: 4828 Avery Ct Project Description: New Townhome, Lot 2, Block 11 Space Type 3-Season Porch . .' 4-Season Porch 'Basement (New) Unfinished Basement Finish Addendum (prior to CO) Basement Finished, Bathroom Remodel ?Bonus Room Finished -- Bonus Room Remodel Bonus'Room;Unfiinished Crawl Space 'Deck Drain Tile ($135 set fee) Egress=Window ($2,000 per-pi Front Stoop Garage (attached with footing; Garage (detached with floating slab }Kitchen. Remodel Lower Level Remodel Main Level Finished Room Addition Rot Repair (per valuation) Screen Porch Screen Porch (aluminum frame Solar Array (per valuation) Sport Court Townhouse Upper Level Finished Upper Level Unfinished Square Feet 24 7 1,070 Amount per Square Foot 60• 00 $ 76.00 $ 16.50 $ 79.23 $ 9573 $ 20.00 95.7 20.00 35.00 8.00 $ 15.0p NA N, 50.00 40.411 $ 30.00 $ 20.00� $ 20.00 $ 95.73 $ 95.73 NA; $ 50.00 $ 30.00 NA $ 16.50 $ $ 87.40 $ $ 95.73. $ $ 35.00 $ Subtotal 1,200.00 Total $ 199,125.45 EAGAN 3830 PILOT KNOB ROAD ( EAGAN, MN 55122-181 c (651) 675-5675 i FAX (651) 675-5694 C buildinginspections citvofeasian.com 2021 FIRE SUPPRESSION SYSTEMS PERMIT APPLICATION For Office Use 7Vi01 L7� Permit # j 1� Permit Fee: Staff: rir Payment Recvd: Yes No Electronic 7 per Plans: Date: Site Address: 4€ Z Aki E-1g Suite #: Tenant: 0 Requirements: 2 complete sets of drawings and specifications, cut sheets on materials and components Phone: Property Owner Type of Work Contractor Name: ?i.ii_"i 14 Mi::S Address / City / Zip: 15b0 OFFUCE. i LI &. C I (zeL� Applicant is: Owner Contractor KFP lq 131) citZE SL (s tv1 Description of work: Construction Cost: -5 t1 .0c Estimated Com•letion Date: '1 / 1 Z 2-2- VI. CZ6 aPPiZL.SStot.i Js✓t )tC.CS License#: c 1 '5- Address: 1502) 6 A XTE R Ro lb 0t 3 City: PgiNCETi.X1 Phone: -762, 1 3r i -2 i 3 Name: FIRE PERMIT TYPE t� Sprinkler System (# of heads t=1 ) Fire Pump Standpipe Other: 1 1I , State: f`"tN Zip: � . t'SC4 bi1t.ST,(Z. Email: r� SC't) >-t °$. orki Contact ' -- WORK TYPE New _ Addition Alterations', _ Remodel Other: DESCRIPTION OF WORK: Commercial )( Residential Educational FEES $60.00 Permit Fee Minimum (does not include State Surcharge) Surcharge = Contract Value x $0.0005 If the project valuation is over $1 million, please call for Surcharge $100.00 Residential New (includes State Surcharge) 3/4" Fire Meter - $300.00 Radio Read (required with Fire Meters) - $205 You may subscribe to receive an electronic notification from the City of proposed ordinances by signing up for an email update on the City's website at www.citvofeaaan.com/subscribe. I hereby apply for a Fire Suppression System permit and acknowledge that the information is complete and accurate: that the work will be in conformance with the ordinances and codes of the City of Eagan and with the Minnesota Building/Fireodes; thatn I undcaserstand of this is which Is not a res permit, but wana approvalan liof plation for a. permit, and work is not to start without a permit; that the work will be in accordance with the approvedplan w _A �)C .Cd Contract Value $ 3q16.00 x .01 (3 C` Permit Fee $ Surcharge $ i;}v + 0 TOTAL FEE = $ t••Il t4 Fire Meter $ tJi TOTAL FEE rtf-l'oc,1 Applicant's Printed Name X `-=i 1ri l Applicant's Signature FOR (VACS USE REQUIRED INSPECTIONS Hydrostatic- Flow Alarm Drain Test"""F ough in Trip pump Test Central Station Final Conditions of Issuance: Permit Reviewed by: 3830 PILOT KNOB ROAD I EAGAN, MN 55122 (651) 675-5675 I FAX: (651) 675-5694 buildinginsr ections ancitvofeagan.com If you have a hearing or speech disability, contact us through your preferred telecommunications relay service.