Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
4832 Avery Court
EAGAN 3830 PILOT KNOB ROAD I EAGAN, MN 55122-1810 (651) 675-5675 I FAX: (651) 675-5694 buildinainsoectionsacitvofeagan. com BL 172762'$6kii•3-1 PL 172763= (oo •oo ME 172764 = (O 0 •f�For office use SW 172765 i Permit #: 172762 ego. 31 Permit Fee: 81 (9%1 *37 Date Received: 10/15/2021 Staff: PF J Loi- 3, ioc k 1 I u-i 0�t 11 2021 RESIDENTIAL BUILDING PERMIT APPLICATION Date: 10/12/21 Site Address: 4832 Avery Court Unit #: 3 Res(dent/ : ` OWt1er Name: Pulte Homes of MN Phone: 763-274-9345 7500 Flying Cloud Drive, Eden Prairie, MN 55344 Address / City / Zip: Applicant is: Owner ✓ Contractor Owner Email: brian.gergen@pultegroup.com Type of Nork Description of work: New Residential Construction Construction Cost: 169,000 Multi -Family Building: (Yes X / No ) Contractor Pulte Homes of MN Company: Contact: 7500 Flying Cloud Drive Eden Prairie Address: City: State: MN Zip: 55344 Phone: Email: ellie.rogers@pultegroup.com License #: BC627723 Lead Certificate #: If the project is exempt from lead certification, please explain why: In the last 12 months, Yes ✓ No COMPLETE THIS AREA ONLY IF CONSTRUCTING A NEW BUILDING has the City of Eagan issued a permit for a similar plan based on a master plan? If yes, date and address of master plan: Licensed Plumber: Mechanical Contractor: Sewer & Water Contractor: Fire Suppression Contractor: Elander Phone: (763) 473-2267 Elander Phone: (763) 473-2267 Ground Tech Phone: (651) 964-0006 FSS Phone: 651-775-3964 NOTE, Plans and supporting documents that you submit are considered to be public information. Portions of the information maybe classified as non public Ifthat ... you provide` specific reasons that would permit the City to conclude they are trade secrets You may subscribe to receive an electronic notification from the City of proposed ordinances by signing up for an email update on the City's website at www.cityofeagan.com/subscribe. CALL BEFORE YOU DIG. Contact Gopher State One Call at (651) 454-0002 or www.aooherstateonecall.orq for protection against underground utility damage. Contact Gopher State One Call 48 hours before you intend to dig to receive locates of underground utilities. I hereby acknowledge that this information is complete and accurate; that the work will be in conformance with the ordinances and codes of the City of Eagan; that I understand this is not a permit, but only an application for a permit, and work is not to start without a permit; that the work will be in accordance with the approved plan in the case of work which requires a review and approval of plans. )(Steve Brock Applicant's Printed Name 5 S4c.E 9sz 2�9-0?f( Applicant's Signature SUB TYPES Foundation Single Family Multi ✓ 01 of _ Plex WORK TYPES / New Addition Alteration Replace DESCRIPTION Calculated Valuation Plan Review (25%_ 100% ✓ ) Census Code #of Units # of Buildings FOR OFFICE USE ONLY Site Address: 4832 Avery Ct Fireplace Garage Deck Lower Level _ Repair Fire Repair Water Damage Egress Window $200,465.67 5 Type of Construction Not Applicable Permit #: 172762 Porch (3-Season) _ Miscellaneous _ Porch (4-Season) _ Accessory Building Porch (Screen/Gazebo/Pergola) Pool REQUIRED INSPECTIONS ✓ Footings (New Building) Footings (Deck) Footings (Addition) ✓ Foundation ✓ Foundation Before Backfill Roof: _Ice & Water _Final ✓ Framing 30 Minutes ✓ 1 Hour ✓ Fireplace: _Rough In _Air Test _Final ✓ Insulation ✓ Sheathing ✓ Sheetrock ✓ Fire Walls ✓ Braced Walls Shower Pan Reviewed By: /�:7n� Occupancy Code Edition Zoning Stories Square Feet Length Width Siding Reroof Windows Solar IRC-3 Townhouse 2020 MRC 2 1911 Retaining Wall Move Building _ Demolish Building* *Demolition of entire building — give PCA handout to applicant MCES System SAC Units I City Water Booster Pump PRV Fire Suppression Required Meter Size: 3/4 Final / C.O. Required Final / No C.O. Required HVAC _ Service Test Gas Line Air Test _ Hood Pool: _Footings _Air/Gas Tests _Final Drain Tile Siding: _Stucco Lath ✓Stone Lath _Brick _ EFIS Windows Retaining Wall: _ Footings _ Backfill _ Final Radon Control Fire Suppression: ✓ Rough In ✓ Final Erosion Control Other: Permit Required: , Building Inspector Stormwater Management RESIDENTIAL FEES Calculated Valuation $ 200,465.67 Base Fee Plan Review State Surcharge MCES SAC City SAC Utility Connection Charge S&W Permit & Surcharge Treatment Plant Radio Read Other: 3/4" Meter Copies: $ 1,662.75 $ 1,080.79 $ 100.23 $ 2,485.00 $ 122.10 $ 1,592.90 $ 129.00 $ 989.60 $ 205.00 $ 300.00 TOTAL $ 8,667.37 Residential Permit Valuation Calculations Site Address: 4832 Avery Ct Project Description: New townhome, Lot 3, Block 11 Space Type Square Feet 3-Season Porch 4-Season Porch Basement (New) Unfinished Basement Finish Addendum (prior to CO) Basement Finished Bathroom Remodel Bonus Room Finished Bonus Room Remodel Bonus Room Unfinished Crawl Space Deck Drain Tile ($135 set fee) Egress Window ($2,000 per pit) Front Stoop Garage (attached with footings) Garage (detached with floating slab) Kitchen Remodel Lower Level Remodel Main Level Finished Room Addition Rot Repair (per valuation) Screen Porch Screen Porch (aluminum frame) Solar Array (per valuation) Sport Court Townhouse Upper Level Finished Upper Level Unfinished Amount per Square Foot $ 60.00 $ $ 76.00 $ $ 16.50 $_ $ 79.23 $ $ 95.73 $ $ 20.00 $ $ 95.73 $ $ 20.00 $ $ 35.00 $ 8.00 $ $ 15.00 $ NA NA 24 $ 50.00 $ 404 $ 40.41 $ $ 30.00 $ $ 20.00 $ $ 20.00 $ 827 1,084 $ 95.73 95.73 NA 50.00 $ 30.00 $ NA 16.50 87.40 95.73 35.00 $ Subtotal 1,200.00 16,325.64' 79 168.71 103,771.32 Total $ 200,465.67 Lot 3, low ► ► 4952 fie. a> c ns U O • Z < O ❑ ❑ ❑✓ ❑ ❑ ❑✓ ❑ ❑ ❑✓ ❑ ❑ O ❑ ❑ ❑ ❑ ❑ ✓❑ 01=1 E9 O ❑ ❑ O ❑ ❑ ❑ ❑✓ ❑ ❑ 0 ❑ ❑✓ ❑ ❑ O ❑ ❑ O ❑ ❑ ❑ 0 ❑ }00) 1! Ell El Aw C2(❑ 0 Yes ❑ ❑✓ ❑ ❑ 0 ❑ ❑ 0 ❑ ❑ ❑✓ ❑ ❑ 0❑ ❑ 0 ❑ No INo I PROPERTY LEGAL: LOT SURVEY CHECKLIST FOR RESIDENTIAL BUILDING PERMIT APPLICATION Lots 1, 2, 3, 4, & 5, Block 11, Avery Pines DATE OF SURVEY: 9/23/21 LATEST REVISION: Ilk f DOCUMENT STANDARDS • Registered Land Surveyor signature and company • Building Permit Applicant • Legal description • Address • North arrow and scale • House type (rambler, walkout, split w/o, split entry, lookout, etc.) • Directional drainage arrows with slope/gradient % • Proposed/existing sewer and water services & invert elevation • Street name • Driveway (grade & width - in R/W and back of curb, 22' max.) • Lot Square Footage • Lot Coverage ELEVATIONS Existing • Property corners • Top of curb at the driveway and property line extensions • Elevations of any existing adjacent homes • Adequate footing depth of structures due to adjacent utility trenches • Waterways (pond, stream, etc.) Proposed • Garage floor • Basement floor • Lowest exposed elevation (walkout/window) • Property corners • Front and rear of home at the foundation • PRV Required PONDING AREA (if applicable) • Easement line • NWL • HWL • Pond # designation • Emergency Overflow Elevation • Pond/Wetland buffer delineation • Shoreland Zoning Overlay District • Conservation Easements DIMENSIONS • Lot lines/Bearings & dimensions • Right-of-way and street width (to back of curb) • Proposed home dimensions including any proposed decks, overhangs greater than 2', porches, etc. (i.e. all structures requiring permanent footings) • Show all easements of record and any City utilities within those easements • Setbacks of proposed structure and sideyard setback of adjacent existing structures • Retaining wall requirements: Reviewed By: Dave Westermayer Date 11/1/21 //1/Z/'ca / G:/1 Engineering/Forms/Cert. of Survey Checklist Fillable 03-16-2021 L-O 31 loc*- I t 4 8 32_ A vein* C,1- 3:1 Maximum Slope3 or Piraining Wail W i Be required Lot 1 Lot area = 2407 SF House area = 1330 SF Porch area = 22 SF Sidewalk area = 46 SF Driveway area = 91 SF Patio area = 82 SF Total Impervious Area = 1571 SF Impervious Coverage = 65.3% Lot 2 Lot area = 2004 SF House area = 1233 SF Porch area = 22 SF Sidewalk area = 46 SF Driveway area = 121 SF Patio area = 83 SF Total Impervious Area = 1505 SF Impervious Coverage = 75.1% Lot 3 Lot area = 2004 SF House area = 1232 SF Porch area = 22 SF Sidewalk area = 46 SF Driveway area = 91 SF Patio area = 83 SF Total Impervious Area = 1474 SF Impervious Coverage = 73.6% Lot4 II \\ \` II _ I Ben ¢mar/ I/ I / n / II I I Co I I I I / II I 7 j II I i3.910 II I BB Bnlimarlgl III--t -2410 L--�I II I� I I I nB I Lot area = 2004 SF L = _ - Q Porch area = 22 SF Sidewalk area = 46 SF Driveway area = 121 SF Patio area = 82 SF Total Impervious Area = 1608 SF Impervious Coverage = 80.2% House area = 1337 SF Lot 5 Lot area = 2407 SF House area = 1226 SF Porch area = 22 SF Sidewalk area = 49 SF Driveway area = 152 SF Patio area = 83 SF Total Impervious Area = 1532 SF Impervious Coverage = 63.6% 943 74 Ben hmark I I B nchmar I2 " // I I I I I I Construction Notes: 1. Install rock construction entrance. 2. Install silt fence as needed for erosion control. 3. Sidewalks shall drain away from house a minimum of 1.0%. 4. Contractor must verify driveway design. 5. Contractor must verify service elevation prior to construction. 6. Add or remove foundation ledge as required. 7. Retaining walls are conditional; Wall installed if the grade exceeds 3:1. Wall will not be installed if the grade is 3:1 or less. ■ I/ / COI ROL X 943.2 ) I 94 93 // B ilChmark- -= 944.0 X 943.7 P • 465, X 000.00 ( 000.00 ) General Notes: 1. Grading plan by Pioneer last dated 7-7-21 was used to determine proposed elevations shown herein. 2. This survey does not purport to show improvements or encroachments, except as shown, as surveyed by me or under my direct supervision. 3. Proposed building dimensions shown are for horizontal location of structures on the lot only. Contact builder prior to construction for approved construction plans. 4. No specific soils investigation has been performed on this lot by the surveyor. The suitability of soils to support the specific house proposed is not the responsibility of the surveyor. 5. This certificate does not purport to show easements other than those shown on the recorded plat. 6. Bearings shown are based on an assumed datum. PISNEERengineering, PA CIVIL ENGINEERS LAND PLANNERS LAND SURVEYORS LANDSC APE ARCIrITECTS 2422 Enterprise Drive Ph. : (651) 681-1914 Mendota Heights, MN 55120 Fax: (651) 681-9488 www pioneereng.com !Project # :121194000'Folder #:85571Drawn by: CWM. hr *SITE UNDER CONSTRUCTION* All curb and utilities shown are proposed (945.0 S87°04'10"E x 944.0 N87°04'10"W x 943.6 (944.3) X 943.9 Denotes iron pipe Denotes service Denotes television box Denotes electric box Denotes telephone box Denotes existing elevation Denotes proposed elevation Denotes drainage flow direction Denotes spike Denotes proposed retaining wall designed and built by others. By Date EAGAN ENGINEERING ING DEPT: 83.50 X 944.7 83.50 X 943.9 House elevations Top Of Foundation Elev. Garage Slab Elev. © Door (942.5) X 942.8 172 76 2- X 944.7 944.0 M co X 945.5 944.22 Benchmark X 944.5 944.05 Benchmark X 943.7 CO CO 0 (7) N N �- O O 944.24 Benchmark X 943.0 943.15 /- Benchmark 942.6X O to N O X 942.4 943.16 Benchmark X 942.0 942.56 Benchmark X 941.4 i -1 V (Proposed) / As -built :(946.2) / : (945.7) / EWED rl We hereby certify to Pulte Group that this survey, plan or report was prepared by me or under my direct supervision, and that I am a duly licensed Land Surveyor under the laws of the State of Minnesota, dated 09/23/21. Signed: //Pi, eer Engineering, P.A. BY: Peter J. Hawkinson, "Professional Land Surveyor Minnesota License No. 42299 email-phawkinson©pioneereng.com Lots 1,2,3,4,5, Block 11, AVERY PINES according to the recorded plat thereof Dakota County, Minnesota Address: 410061.sili Avery Court, Eagan, Minnesota House Model: Bowman, Ashton, Bowman, Ashton, Bowman Elevation: EL1 Buyer: N/A 010' 20111 Scale: 1" = 20' Benchmark: Top Nut Hydrant Elevation = Revisions: 1.) 10-18-21 Stake house 2.) 11-01-21 City comments Certificate of Survey for: Pulte Group 7500 Flying Cloud Drive Ste 670 Eden Prairie, MN 55344 (cl Pinnv,-r F„oir,,.'rincr EAGAN 3830 PILOT KNOB ROAD I EAGAN, MN 55122-1810 _ (651) 675-5675 i FAX: (651) 675-5694 �D F - 2 buildinainspections@citvofeaaan.com 2021 FIRE SUPPRESSION SYSTEMS PERMIT APPLICATION Date: Site Address: tZ For Office Use / / Permit #: l// -.7q0/U 1 � Permit Fee: /Dy /.y Staff: Payment Recvd: yes No Plans: Electronic % Paper Suite #: Tenant: 0 Requirements: 2 complete sets of drawings and specifications, cut sheets on materials and components Phone: q 5 Z- 2-"Zq - 0 3 Contractor Address / City / Zip: 't'Z 6Q 'F t E 13 10(,6. CIRO. Lc A. • licant Is: Owner g Contractor Description of work: KIFP (a 13t `- l (-'tK. ( t<L Z. S I 5` U"U t" i Construction Cost: \ ` e► OC Estimated Com•Ietion Date: c-t gg CUtPPl2E.SStCt k SCROiC-&- License#: L-t45 Address: Q 50(6 ISA &TTR Ro o 3 City: Ri NC.E.TOu i IN J t `� State: 1_Zip: J5r? W11 Phone: 7( - % t -23 J 17 SG C,�1't4T-ih.. Email: + C( SC>15. (A. � ' . C:4 Contact: �` _ _.._.. _ _. _.... FIRE PERMIT TYPE Sprinkler System (# of heads VT — Fire Pump _ Standpipe Other: DESCRIPTION OF WORK- Commercial FEES $60.00 Permit Fee Minimum (does not include State Surcharge) Surcharge = Contract Value x $0.0005 If the project valuation is over $1 million, please call for Surcharge $100.00 Residential New (includes State Surcharge) 3/4" Fire Meter - $300.00 Radio Read (required with Fire Meters) - $205 WORK TYPE New __ Addition Alterations Remodel „ .. Other: Residential Educational Contract Value $ 3q 16'00 x .01 = $ ( .' .rD" Permit Fee ,�1 1 = $ 1Surcharge $ (Od + 0 Q TOTAL FEE = $ t- ! A. Fire Meter _$ PJ 1 TOTAL FEE You may subscribe to receive an electronic notification from the City of proposed ordinances by signing up for an email update on the City's website at www,citvofeacian.com/subscribe. I hereby apply for a Fire Suppression System permit and acknowledge that the information is complete and accurate; that the work will be in conformance with the ordinances and codes of the City of Eagan and with the Minnesota Building/Fire Codes; that I understand this is not a permit, but only an application for a permit, and work is not to start without a permit; that the work will be in accordance with the approved plan in the case of work which requires a review and approval of plans. Applicant's Printed Name Applicant's Signature /7 boy 9 FOR OFFICE USE REQUIRED INSPECTIONS Flow Alarm Drain Test Pump Test Central Station Condition Permit Revi 3830 PILOT KNOB ROAD I EAGAN, MN 55122 (651) 675-5675 I FAX: (651) 675-5694 buildinginspections@cityofeagan.com If you have a hearing or speech disability, contact us through your preferred telecommunications relay service.