774 Summerbrooke Ct gL i�Z v43 Iq I44. It Q4_0 �
T100. 00
nn t✓ i�-� °3Il 3
I I For Office Use
% 0 i
0 0 or S+4. it I Permit*EAG "C ,
Permit Fee:
Date Received: I
3830 PILOT KNOB ROAD I EAGAN, MN 55122-1810 SEP 13 2021 1 Staff: j
(651)675-5675 i FAX: (651)675-5694
buildinginspections(cDcitvofeaoan.com I
Q 2021 RESIDENTIAL BUILDING PERMIT APPLICATION
Date: O 301 Site Address: 774 Summerbrooke C.�• Unit#:
Name: Eternity Homes LLC Phone: 651-460-3043
Resident/ 425 3rd St/ Farmington / 55024
Owner Address/City/Zip:
Applicant is: 'V( Owner V/ Contractor Owner Email: draftingeternityhomesllc@gmail.com
Type of Work
Description of work: New Residential Single Family Home
Construction Cost: $150,000 Multi-Family Building: (Yes /No X )
Company: Eternity Homes LLC Contact: Ann Hamman
Contractor
Address: 425 3rd St City: Farmington
State: MN Zip: 55024 Phone: 651-460-304p Email: draftingeternityhomesllc@gmail.com
License#: BC638704 Lead Certificate#:
If the project is exempt from lead certification, please explain why:
D m o_."
COMPLETE THIS AREA ONLY IF CONSTRUCTING A NEW BUILDING
In the last 12 months, has the City of Eagan issued a permit for a similar plan based on a master plan?
Yes No If yes,date and address of master plan: 787 Summerbrooke Ct, 04/12/21
Licensed Plumber: Stewart Plumbing Inc Phone: 763-428-4833
Mechanical contractor: Burnsville Heating & Air Phone: 952-894-0005
Sewer&water Contractor: DSM Excavation Co Phone: 651-480-1355
Fire Suppression Contractor: Phone:
NOTE:Plans and supporting documents that you submit are considered to be public information. Portions of the information may be
classified as non-public if you pmvide specific reasons that would permit the City to conclude that they are trade secrets.
You may subscribe to receive an electronic notification from the City of proposed ordinances by signing up for an email update on the City's website at
www.citvofeagan.com/subscribe.
CALL BEFORE YOU DIG. Contact Gopher State One Call at(651)454-0002 or www.00r)herstateonecall.org for protection against underground utility
damage. Contact Gopher State One Call 48 hours before you intend to dig to receive locates of underground utilities.
I hereby acknowledge that this information is complete and accurate;that the work will be in conformance with the ordinances and codes of the City of
Eagan; that I understand this is not a permit, but only an application for a permit, and work is not to start without a permit; that the work will be in
accordance with the approved plan in the case of work which requires a review and approval of plans.
x Coral Ozmun x
Applicant's Printed Name Applicant's Signature
v
FOR OFFICE USE ONLY
Site Address: �t,ti wimp p b2o oke Cf Permit#: 1 1'2 o -t3
SUB TYPES
Foundation _ Fireplace _ Porch(3-Season) _ Miscellaneous
Single Family _ Garage _ Porch(4-Season) _ Accessory Building
Multi _ Deck _ Porch(Screen/Gazebo/Pergola)
01 of_Plex _ Lower Level _ Pool
ORK TYPES
New _ Repair _ Siding _ Retaining Wall
_ Addition _ Fire Repair _ Reroof _ Move Building
Alteration _ Water Damage _ Windows _ Demolish Building*
Replace Egress Window _ Solar *Demolition of entire building—give PCA
handout to applicant
DESCRIPTION
Calculated Valuation I I Occupancy /v \ MCES System
Plan Review Code Edition SAC Units
(25%_1000/4—) Zoning City Water
Census Code Stories Booster Pump
#of Units Square Feet PRV
#of Buildings Length Fire Suppression Required
Type of Construction Width
REQUIRED INSPECTIONS
Footings(New Building) Meter Size:
Footings(Deck) Final/C.O. Required
Footings(Addition) Final/No C.O. Required
4- Foundation Foundation Before Backfill HVAC_Service Test Gas Line Air Test_Hood
Roof:_Ice&Water _Fin I Pool:_Footings _Air/Gas Tests _Final
Framing 30 Minutes 1 Hour Drain Tile
Fireplace: Rough In Air Test 4Final Siding:_Stucco LathSDneLat _Brick_EFIS
Insulation Windows
Sheathing Retaining Wall:_Footings_Backfill Final
Sheetrock Radon Control
Fire Walls Fire Suppression:_Rough In_Final
Braced Walls Erosion Control
Shower Pan �} Other:
eviewed By: I , Building Inspector
RESIDENTIAL FEES
Calculated Valuation
Base Fee 3 �rh , r �`�
Plan Review AAA",'
l
g f. �( I` Q1��7;= �✓ �1�
State Surcharge �
� I
MCES SAC1�..�
City SAC f/ l
Utility Connection Charge
S&W Permit&Surcharge f
Treatment Plant ✓YI'` O q o)ql_-
Radio Read n � ,r� �} O
Other: (/
�i{ l�j'L x
Copies:
TOTAL $0.00 `
3q;t
2 y
.J
New Construction Energy Code Compliance Certificate
Per R401.3 Certificate.A building certificate shall be posted on or in the electrical distribution Date Certificate Posted
panel. 7/12/2021
Place your
Mailing Address of the Dwelling or Dwelling Unit City logo here
774 Summerbrooke Eagan
Name of Residential Contractor MN License Number
Eternity Homes LLC BC638704
THERMAL ENVELOPE RADON CONTROL SYSTEM
Type:Check All That Apply X Passive(No Fan)
Active(With fan and monometer or other
N c
system monitoring device)
N �
n Location(or future location)of Fan:
_ n a
m — o
U C d
o n 3 y U a) o o °
0 0 2
o Q m m a U a) -oo c'
to _ c
> N w a a o
Insulation Location � ° z m m O O zz w N
m o F E a -o a
FD
N co 9 0 o c rn 'a
F z i LL Other Please Describe Here
Below Entire Slab
Foundation Wall 10 X
Perimeter of Slab on Grade 15 X
Rim Joist(1 st Floor) 21 X
Rim Joist(2nd Floor+) 21 X
Wall 20 X
Ceiling,flat 49 X
X
Ceiling,vaulted 49 txx Bay Windows or cantilevered areas 30
Floors over unconditioned area 3o
Describe other insulated areas
Building envelope air tightness: Duct system air tightness:
Windows&Doors Heating or Cooling Ducts Outside Conditioned Spaces
Average U-Factor(excludes skylights and one door) J:50-28 X Not applicable,all ducts located in conditioned space
Solar Heat Gain Coefficient(SHGC): 10.22 R-value R-8 in garage area
MECHANICAL SYSTEMS Make-up Air Select a Type
Appliances Heating System Domestic Water Cooling System
Heater X Not required per mech.code
Fuel Type Gas Gas R-41 OA Passive
Manufacturer Daikin A.O Smith Daikin Powered
Interlocked with exhaust device.
Model DM92SE0603B PNT-50 DX13SNO24 Describe:
Input in 60,000 Capacity in 50 Output 2 Other,describe:
Rating or Size BTUS: Gallons: in Tons:
AFUE or 92% SEER 13 Location of duct or system:
Efficiency HSPF% /EER
Heating Loss Heating Gain Cooling Load
Residential Load Calculation 45,399 13,276 18,881
Cfm's
"round duct OR
MECHANICAL VENTILATION SYSTEM ,metal duct
Describe any additional or combined heating or cooling systems if installed:(e.g.two furnaces or air Combustion Air Select a Type
source heat pump with gas back-up furnace): Not required per mech.code
Select Type 6" Passive
X Heat Recover Ventilator(HRV) Capacity in cfms: Low: 82 High: 190 Other,describe:
Energy Recover Ventilator(ERV)Capacity in cfms: Low: High: I Location of duct or system:
Balanced Ventilation capacity in cfms:
Location of fan(s),describe: I Cfm's
Capacity continuous ventilation rate in cfms: "round duct OR
Total ventilation(intermittent+continuous)rate in cfms: "metal duct
Builders Association of Minnesota version 101014
Burnsville Heating & Air Conditioning, Inc.
3451 W. Burnsville Pkwy,Suite 120, Burnsville, MN 55337
Phone 952-894-0005—Fax 952-894-0925—Web www.burnsvilleheating.com
Ventilation, Makeup and Combustion Air Calculations
Submittal Form for New Dwellings
Site address 774 Summerbrooke Ct Date 7/12/2021
Contractor Burnsville Heating&Air Conditioning,Inc Completed By I Alan Dobson
VENTILATION REQUIREMENTS
TABLE R403.5.2
NUMBER OF BEDROOMS
1 2 3 4 5 62
Conditioned spacel(in Total/ Total/ Total/ Total/ Total/ Total/
sq.ft.) Continuous Continuous Continuous Continuous Continuous Continuous
1000-1500 60/40 75/40 90/45 105/53 120/60 135/68
1501-2000 70/40 85/43 100/50 115/58 130/65 145/73
2001-2500 80/40 95/48 110/55 125/63 140/70 155/78
2501-3000 90/40 105/53 120/60 135/68 150/75 165/83
3001-3500 100/50 115/58 130/65 145/73 160/80 175/88
3501-4000 110/55 125/63 140/70 155/78 170/85 185/93
4001-4500 120/60 135/68 150/75 165/83 180/90 195/98
4501-5000 130/65 145/73 160/80 175/88 190/95 205/103
5001-5500 140/70 155/78 170/85 185/93 200/100 215/108
5501-60002 150/75 165/83 180/90 195/98 210/105 225/113
1. Conditioned space includes the basement and conditioned crawl spaces.
2. If conditioned space exceeds 6000sp. Ft.or there are more than 6 bedrooms,use Equation R403.5.2
R403.5.2 Total Ventilation rate.
The mechanical ventilation system shall provide sufficient outdoor air to equal the total ventilation rate average
for each 1-hour period in accordance with Table R403.5.2,or Equation 403.5.2, based on the number of bedrooms
and square footage of conditioned space,including the basement and conditioned crawl spaces.
For the purposes of Table R403.5.2 and Section R403.5.3,the following applies"
a. Equation R403.5.2 Total ventilation rate:
Total ventilation rate(cfm)_(0.02 x square feet of conditioned space)+(15 x(number of bedrooms=1))
b. Equation R403.5.2.1 Continuous ventilation rate:Continuous ventilation rate(cfm)=Total ventilation
rate/2
Amount Total 155
Amount Continuous 78
BI�RNSVILLE
Heating&Air Conditioning,Inc.
TABLE 304.1
COMBUSTION AIR REQUIREMENTS FOR GAS-FIRED
APPLIANCES WHEN THE COMBINED INPUT IS UP TO
AND INCLUDING 400,000 Btu/hr
REQUIRED FREE AREA OF AIR- ACCEPTABLE APPROXIMATE
TOTAL INPUT OF APPLIANCESi, SUPPLY OPENING OR DUCT, ROUND DUCT
THOUSANDS OF Btu/hr SQUARE INCHES EQUIVALENT DIAMETER2,
(kW) (sq mm) INCH (mm)
25 (8) 7 (4,500) 3 (75)
50(15) 7 (4,500) 3 (75)
75 (23) 11(7,000) 4(100)
100(30) 14(9,000) 4(100)
125 (37) 18(12,000) 5 (125)
150(45) 22(14,000) 5 (125)
175 (53) 25(16,000) 6(150)
200(60) 29(19,000) 6 (150)
225 (68) 32(21,000) 6 (150)
250(75) 36(23,000) 7 (175)
275 (83) 40(26,000) 7 (175)
300(90) 43 (28,000) 7 (175)
325 (98) 47 (30,000) 8(200)
350(105) 50(32,000) 8(200)
375 (113) 54(35,000) 8(200)
400(120) 58(37,000) 9(225)
1. For total inputs falling between listed capacities, use next largest listed input.
2. If flexible duct is used, increase the duct diameter by one inch.
*Flexible duct shall be stretched with minimal sags.
BTU Amount for Non-direct vent appliances
BURNSVILLE
Heating&Air Conditioning,Inc.
IFGC Appendix E,Worksheet E-1
Residential Combustion Air Calculation Method
(for Furnace,Boiler,and/or Water Heater in the Same Space)
Step 1:Complete vented combustion appliance information.
Furnace/Boiler:
_Draft Hood _Fan Assisted _Direct Vent Input
(Not fan assisted) &Power Vent Btu/hr
Water Heater:
_Draft Hood _Fan Assisted _Direct Vent Input:
(Not fan assisted) &Power Vent Electric_Btu/hr
Step 2:Calculate the volume of the Combustion Appliance Space(CAS)containing combustion appliances.
The CAS includes all spaces connected to one another
by code compliant openings. CAS volume: ft3
Step 3:Determine Air Changes per Hours(ACH)1
Default ACH values have been incorporated into Table E-1 for use with Method 4b(KAIR Method).
If the year of construction or ACH is not known,use method 4a(Standard Method).
Step 4:Determine Required Volume for Combustion Air.
4a.Standard Method
Total Btu/hr input of all combustion appliances Input:
Btu/hr
(DO NOT COUNT DIRECT VENT APPLIANCES)
Use Standard Method column in Table E-1 to find Total Required Volume(TRV)
TRV: ft3
If CAS Volume(from Step 2)is greater than TRV then no outdoor openings are needed.
If CAS Volume(from Step 2)is less than TRV then go to STEP S.
4b.Known Air Infiltration Rate(KAIR)Method
Total Btu/hr input of all fan-assisted and power vent appliances Input:
Btu/hr
(DO NOT COUNT DIRECT VENT APPLIANCES)
Use Fan-Assisted Appliances column in Table E-1 to find
Required Volume Fan Assisted(RVFA)
RFVA: ft3
Total Btu/hr input of all non-fan-assisted appliances Input:
Btu/hr
Use Non-Fan-Assisted Appliances column in Table E-1 to find
Required Volume Non-Fan-Assisted(RVNFA)
RVNFA: ft3
Total Required Volume(TRV)=RVFA+RVNFA
RV= + — ft3
If CAS Volume(from Step 2)is greater than TRV then no outdoor openings are needed.
If CAS Volume(from Step 2)is less than TRV then go to STEP S.
Step 5:Calculate the ratio of available interior volume to the total required volume.
Ratio=CAS Volume(from Step 2)divided by TRV(from Step 4a or Step 4b) Ratio
Step 6:Calculate Reduction Factor(RF).
RF-1 minus Ratio RF=1-
Step 7:Calculate single outdoor opening as if all combustion air is from outside.
Total Btu/hr input of all Combustion Appliances in the same CAS (EXCEPT DIRECT VENT) Input:
Btu/hr
Combustion Air Opening Area(CAOA):
Total Btu/hr divided by 3000 Btu/hr per int CAOA= /3000 Btu/hr per in 2=
int
Step 8:Calculate Minimum CAOA.
Minimum CAOA=CAOA multiplied by RF Minimum CAOA= x =
int
Step 9:Calculate Combustion Air Opening Diameter(CAOD)
CAOD=1.13 multiplied by the square root of Minimum CAOA CAOD=1.13 V Minimum CAOA
- in.
1 If desired,ACH can be determined using ASHRAE calculation or blower door test.Follow procedures in Section
G304.
ANUMNSVILLE
Heating&Air Conditioning,Inc.
IFGC Appendix E,Table E-1
Residential Combustion air(Required Interior Volume Based on Input Rating of Appliance)
Known Air Infiltration Rate(KAIR)Method(ft3)
Input Rating Fan Assisted I Non-Fan-Assisted
(Btu/hr) Standard Method
(ft3) 19941 to present Pre-1994 1994 to present Pre-1994
5,000 250 375 188 525 263
10,000 500 750 375 1,050 525
15,000 750 1,125 563 1,575 788
20,000 1,000 1,500 750 2,100 1,050
25,000 1,250 1,875 938 2,625 1,313
30,000 1,500 2,250 1,125 3,150 1,575
35,000 1,750 2,625 1,313 3,675 1,838
40,000 2,000 3,000 1,500 4,200 2,100
45,000 2,250 3,375 1,688 4,725 2,363
50,000 2,500 3,750 1,675 5,250 2,625
55,000 2,750 4,125 2,063 5,775 2,888
60,000 3,000 4,500 2,250 6,300 3,150
65,000 3,250 4,875 2,438 6,825 3,413
70,000 3,500 5,250 2,625 7,350 3,675
75,000 3,750 5,625 2,813 7,875 3,938
80,000 4,000 6,000 3,000 8,400 4,200
85,000 4,250 6,375 3,188 8,925 4,463
90,000 4,500 6,750 3,375 9,450 4,725
95,000 4,750 7,125 3,563 9,975 4,988
100,000 5,000 7,500 3,750 10,500 5,250
105,000 5,250 7,875 3,938 11,025 5,513
110,000 5,500 8,250 4,125 11,550 5,775
115,000 5,750 8,625 4,313 12,075 6,038
120,000 6,000 9,000 4,500 12,600 6,300
125,000 6,250 9,375 4,688 13,125 6,563
130,000 6,500 9,750 4,875 13,650 6,825
135,000 6,750 10,125 5,063 14,175 7,088
140,000 7,000 10,500 5,250 14,700 7,350
145,000 7,250 10,875 5,438 15,225 7,613
150,000 7,500 11,250 5,625 15,750 7,875
155,000 7,750 11,625 5,813 16,275 8,138
160,000 8,000 12,000 6,000 16,800 8,400
165,000 8,250 12,375 6,188 17,325 8,663
170,000 8,500 12,750 6,375 17,850 8,925
175,000 8,750 13,125 6,563 18,375 9,188
180,000 9,000 13,500 6,750 18,900 9,450
185,000 9,250 13,875 6,938 19,425 9,713
190,000 9,500 14,250 7,125 19,950 9,975
195,000 9,750 14,625 7,313 20,475 10,238
200,000 10,000 15,000 7,500 21,000 10,500
205,000 10,250 15,375 7,688 22,525 10,783
210,000 10,500 15,750 7,875 22,050 11,025
215,000 10,750 16,125 8,063 22,575 11,288
220,000 11,000 16,500 8,250 23,100 11,550
225,000 11,250 16,875 8,438 23,625 11,813
230,000 11,500 17,250 8,625 24,150 12,075
1 The 1994 date refers to dwellings constructed under the 1994 Minnesota Energy Code.The default KAIR used in this section of the table is 0.20 ACH.
2 This section of the table is to be used for dwellings constructed prior to 1994.The default KAIR used in this section of the table is 0.40 ACH.
BURNSVILLE
Heating&Air Conditioning,Inc.
Table 501.4.1
Procedure to Determine Makeup Air Quantity for Exhaust Appliances in Dwelling Units
MULTIPLE
ONE OR MULTIPLE ONE OR MULTIPLE ONE APPLIANCES THAT
POWER VENT OR FAN-ASSISTED ATMOSPHERICALLY ARE
DIRECT VENT APPLIANCES AND VENTED GAS OR OIL ATMOSPHERICALLY
APPLIANCES OR NO POWER VENT OR APPLIANCE OR ONE VENTED GAS OR OIL
COMBUSTION DIRECT VENT SOLID FUEL APPLIANCES OR SOLID
APPLIANCESA APPLIANCESB APPLIANCEc FUEL APPLIANCESD
1.Use Appropriate Column to Estimate House Infiltration
a)pressure factor
(cfm/sf) 0.15 0.09 0.06 0.03
b)conditioned floor 3620
area(sf)
(including unfinished basements)
Estimated House 543
Infiltration(cfm):
[lax lb]
2. Exhaust Capacity
a)Clothes dryer 135 135 135 135
b)80%of largest 64
exhaust
rating(cfm)
(not applicable if recirculating system or if powered makeup air is electrically interlocked and matched to exhaust
c) 80%of next 64
largest
exhaust rating
(cfm):
(not applicable if recirculating system or if powered makeup air is electrically interlocked and matched to exhaust
Total Exhaust Capacity 263
(cfm):
[2a+2b+2c]
3. Makeup Air Requirement
547)Total Exhaust 263
Capacity
(from above)
b) Estimated 543
House
Infiltration
(from above)
Makeup Air -280
Quality(cfm):
[3a-3b]
(if value is negative,no makeup air is needed
4. For Makeup Air opening Sizing,refer to Table 501.4.2
A.Use this column if there are other than fan-assisted or atmospherically venter gas or oil appliances or if there are no combustion appliances.
B.Use this column if there is one fan-assisted appliance per venting system.Other atmospherically vented appliances may also be included.
C.Use this column if there is one atmospherically vented(other than fan-assisted)gas or oil appliance per venting system or one solid fuel appliance.
D.Use this column if there are multiple atmospherically vented gas or oil appliances using a common vent or if there are atmospherically vented gas or oil
Si1RNS'VILLE
Heating&Air Conditioning,Inc.
Table 501.4.2
Makeup Air Opening Sizing Table for New and Existing Dwelling Units
MULTIPLE
ONE OR MULTIPLE ONE OR MULTIPLE ONE APPLIANCES THAT
POWER VENT OR FAN-ASSISTED ATMOSPHERICALLY ARE
DIRECT VENT APPLIANCES AND VENTED GAS OR OIL ATMOSPHERICALLY PASSIVE MAKEUP
APPLIANCES OR NO POWER VENT OR APPLIANES OR ONE VENTED GAS OR OIL AIR OPENING DUCT
TYPE OF OPENING COMBUSTION DIRECT VENT SOLID FUEL APPLIANCES OR DIAMETERrz,F,G
OR SYSTEM APPLIANCESA APPLIANCESB APPLIANCEc SOLID FUEL
APPLIANCESD
(cfm) (cfm) (cfm) (cfm) (inches)
Passive opening 1-36 1-22 1-15 1-9 3
Passive opening 37-66 23-41 16-28 10-17 4
Passive opening 67-109 42-66 29-46 18-28 5
Passive opening 110-163 67-100 47-69 29-42 6
Passive opening 164-232 101-143 70-99 43-61 7
Passive opening 233-317 144-195 100-135 62-83 8
Passive opening
w/motorized 318-419 196-258 136-179 84-110 9
damper
Passive opening
w/motorized 420-539 259-332 180-230 111-142 10
damper
Passive opening
w/motorized 540-679 333-419 231-290 143-179 11
damper
Powered
makeup airH >679 >419 >290 >179 NA
A.Use this column if there are other than fan-assisted or atmospherically vented gas or oil appliances or if there are no combustion appliances.
B.Use this column if there is one fan-assisted appliance per venting system.Other than atmospherically vented appliances may also be included.
C.Use this column if there is on atmospherically vented(other than fan-assisted)gas or oil appliance per venting system or one solid fuel appliance.
D.Use this column if there is multiple atmospherically vented gas or oil appliances using a common vent or I there are atmospherically vented gas or oil appliances
and solid fuel appliances.
E.An equivalent length of 100 feet of round smooth metal duct is assumed.Subtract 40 feet for the exterior hood and ten feet for each 90-degree elbow to
determine the remaining length of straight duct allowable.
F.If flexible duct is used,increase the duct diameter b one inch.Flexible duct shall be stretched with minimal sags.
G.Barometric dampers are prohibited in passive makeup air openings when any atmospherically vented appliance is installed.
H.Powered makeup air shall be electrically interlocked with the largest exhaust system.
MSPO#Erl
ville,<MN X5337 x T- 5n ".' 'Paea2,
Project Report —
.�a ,.:iiii �-rANNE-
yyn
Project Title: The San Fran
Designed By: Alan Dobson
Project Date: Friday, February 19,2021
Project Comment:
Client Name: Eternity Homes
Company Name: Burnsville Heating&A/C Inc.
Company Representative: Alan Dobson
Company Address: 3451w Burnsville Pkwy, Suite 120
Company City: Burnsville,MN 55337
Company Phone: 952-894-0005
Company Fax: 952-894-0925
Company Comment:
--9—M—N � ' - � .� - a
�'!" '"��
Reference City: Minneapolis, Minnesota
Building Orientation: Front door faces South
Daily Temperature Range: Medium
Latitude: 44 Degrees
I Elevation: 834 ft.
Altitude Factor: 0.970
Elevation Sensible Adj. Factor: 1.000
Elevation Total Adj. Factor: 1.000
Elevation Heating Adj. Factor: 1.000
Elevation Heating Adj. Factor: 1.000
Outdoor Outdoor Outdoor Indoor Indoor Grains
Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference
Winter: -15 -15.33 80% n/a 72 n/a
Summer: 88 72 47% 50% 75 29
Total Building Supply CFM. 581 CFM Per Square ft.. 0.160
Square ft. of Room Area: 3,620 Square ft. Per Ton: 2,301
Volume(ft')of Cond. Space: 33,656
11
Total Heating Required Including Ventilation Air. 45,399 Btuh 45.399 MBH
Total Sensible Gain: 13,276 Btuh 70 %
Total Latent Gain: 5,606 Btuh 30 %
Total Cooling Required Including Ventilation Air: 18,881 Btuh 1.57 Tons(Based On Sensible+Latent)
W,
We- �N-
Rhvac is an ACCA approved Manual J and Manual D computer program.
Calculations are performed per ACCA Manual J 8th Edition,Version 2,and ACCA Manual D.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at
your design conditions.
i
i
i
i
\\badata\RedirectedFolders ...\NJJ The San Fran 2021 SW.rhv Friday, February 19,2021, 3:26 PM
Bum c Re$idegfial Light Commercial HVAC Loads oftware Devetoprnent,Inc'
sville Heating-B,.AIC tcc r The San Fran:{
1
,E
Burnsville,::MN 55337 Page 11,
Total Building Summary Loads
I r�� �xv_':!-'�-,r'''�`�.'3�isi��Yr-`� h 3a�.y��,'c�i � "y r r ,:'� t�` .r,"z� ;. <3.>- Z- � p�� �k.�, ��:Yxt"�- ,+,�,�a�.`--e•�^.-- m..,, i
,'is�.r' .�'�`$��"�3'F x���`•y'�' a'�` -�,'�3"�'v� '•; � mss. _�yi �! �,xs a s �, z3 �`.�' �� f s
�........_., � r�y,.�""t,u5�� 9-��¢;v:�"7s .a:. <,' x-53`' �•-.' 3 i_ 3 �--�t,yf5��".�,� ;�"_. .� � �^.,-... ,� ��.�.?."�.. '�a.. .,-...4!�,v��tr'`� a I
bah: Glazing-bah, ground reflectance=0.23, u-value 102.5 2,495 0 1,275 1,275
0.28, SHGC 0.22
bah: Glazing-bah, ground reflectance=0.23, u-value 93.5 2,278 0 1,035 1,035
0.28, SHGC 0.22
1 bah: Glazing-bah, ground reflectance=0.23, u-value 25 587 0 201 201 j
0.27, SHGC 0.24
bah: Glazing-bah, ground reflectance=0.23, u-value 42 987 0 330 330 j
0.27, SHGC 0.23
bah: Glazing-bah, ground reflectance=0.23, u-value 11.6 263 0 221 221
0.26, SHGC 0.24
i
bah: Glazing-bah, ground reflectance=0.23, u-value 42 987 0 330 330
0.27, SHGC 0.23
hbt: Door-hbt 20.4 266 0 73 73
hbt: Door-hbt 19 232 0 64 64
f 12F-Osw: Wall-Frame, R-21 insulation in 2 x 6 stud 2895.6 16,371 0 2,504 2,504
cavity, no board insulation, siding finish,wood studs
15BO-15sf-8: Wall-Basement, , R-15 board insulation to 800 2,923 0 0 0
floor, no interior finish, 8'floor depth
R-49-ad: Roof/Ceiling-Under Attic with Insulation on Attic 1263.4 2,199 0 1,213 1,213
! Floor(also use for Knee Walls and Partition
Ceilings), Custom, R-49,dark asphalt
21A-20-v: Floor-Basement, Concrete slab, any thickness, 1200 2,819 0 0 0
2 or more feet below grade, no insulation below floor,
vinyl covering, shortest side of floor slab is 20'wide
Subtotals for structure: 32,407 0 7,246 7,246
People: 5 1,150 1.500 2,650
Equipment: 400 1,200 1,600
Lighting: 0 0 0
Ductwork: 4,613 348 2,187 2,535
Infiltration: Winter CFM: 19, Summer CFM: 0 1,783 0 0 0
I Ventilation:Winter CFM: 192, Summer CFM: 192 6,596 3,708 879 4,587
AED Excursion: 0 0 264 264
Total Building Load Totals: 45,399 5,606 13,276 18,881
� '` x*�,`f '� z `.,,r.x1 a. r- r F § x.x.x�- ys,^� tx � .z•' �,r`� �t a,r .x;.'Yr'"� ''a si � :.;
Total Building Supply CFM: 581 CFM Per Square ft.: 0.160
Square ft. of Room Area: 3,620 Square ft. Per Ton: 2,301
Volume(ft')of Cond. Space: 33,656
t
Total Heating Required Including Ventilation Air: 45,399 Btuh 45.399 MBH
Total Sensible Gain: 13,276 Btuh 70 %
Total Latent Gain: 5,606 Btuh 30 %
Total Cooling Required Including Ventilation Air: 18,881 Btuh 1.57 Tons(Based On Sensible+Latent)
{, � �` ��+ � S'����"'�`3$<'�-e":.� � sx�'a9"�.�'4 r a� L,»- r�r.�"> �* _3 ��+.` T ,:-E .7�- .r tt t 5-c - SiS^�"'�' d ti av .x�a,•'h::
� �����.r3.-, � '`•�,- * =�...y?'.'��-�.� M.,m,:,<g: ..?'S. <`��f,,.#x3€�cl�3a.'o'.0.,,.�: .:.v..-3�Y� a..�Z: �_ �•.,,.�.: __.sa,�.^..3��-"�.,`�'"", „''.� 3�`,`����"w!
Rhvac is an ACCA approved Manual J and Manual D computer program. y
Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at
your design conditions.
I
I
I �
\\badata\RedirectedFolders...\NJJ The San Fran 2021 SW.rhv Friday, February 19, 2021, 3:27 PM
Lac ResMetWA &t.igfrtCoada �'�" Eltte Software D�Yelt3p ld; c;;
svllle Heivattn9&A/C1Rc , " ,
u'_13is�nlle==Ml�
f System 7 Main Floor Summary Loads
Wn. Mill
Nv
bah: Glazing-bah, ground reflectance=0.23, u-value 102.5 2,495 0 1,275 1,275
0.28, SHGC 0.22
bah: Glazing-bah, ground reflectance=0.23, u-value 93.5 2,278 0 1,035 1,035
0.28, SHGC 0.22
bah: Glazing-bah, ground reflectance=0.23, u-value 25 587 0 201 201
0.27, SHGC 0.24
bah: Glazing-bah, ground reflectance=0.23, u-value 42 987 0 330 330
0.27, SHGC 0.23
bah: Glazing-bah, ground reflectance=0.23, u-value 11.6 263 0 221 221
j 0.26, SHGC 0.24
bah: Glazing-bah, ground reflectance=0.23, u-value 42 987 0 330 330
0.27, SHGC 0.23
hbt: Door-hbt 20.4 266 0 73 73 j
hbt: Door-hbt 19 232 0 64 64 i
12F-Osw:Wall-Frame, R-21 insulation in 2 x 6 stud 2895.6 16,371 0 2,504 2,504
cavity, no board insulation, siding finish,wood studs
15BO-15sf-8: Wall-Basement, , R-15 board insulation to 800 2,923 0 0 0
floor, no interior finish, 8'floor depth
R-49-ad: Roof/Ceiling-Under Attic with Insulation on Attic 1263.4 2,199 0 1,213 1,213
Floor(also use for Knee Walls and Partition
Ceilings), Custom, R-49, dark asphalt
21A-20-v: Floor-Basement, Concrete slab, any thickness, 1200 2,819 0 0 0
2 or more feet below grade, no insulation below floor,
vinyl covering, shortest side of floor slab is 20'wide
Subtotals for structure: 32,407 0 7,246 7,246
People: 5 1,150 1,500 2,650
Equipment: 400 1,200 1,600
Lighting: 0 0 0
Ductwork: 4,613 348 2,187 2,535
Infiltration: Winter CFM: 19, Summer CFM: 0 1,783 0 0 0
Ventilation:Winter CFM: 192, Summer CFM: 192 6,596 3,708 879 4,587
' AED Excursion: 0 0 264 264
System 1 Main Floor Load Totals: 45,399 5,606 13,276 18,881
_ x..rs^5;a»�rd7 �'�S• ,•°r 3� �A ' s� sr .` ? S ` ,,, �F �1' fr'a.�..+,�,. to #`:srv+...^t � .v. :L' s.-� I
r.�>-.-.. ' 7 ,. ,. , �, Y'a- .-'.'•w,k�.��,..,�t ,�.�.;`�'S�,`.A,�' .,r�.�i�t�a�:� .� ,:.�. 'rs., :�:^-".�.�a'�.. k ryY- ?'�
Supply CFM: 581 CFM Per Square ft.: 0.160
Square ft. of Room Area: 3,620 Square ft. Per Ton: 2,301
Volume(ft')of Cond. Space: 33,656
....ry a: .. ,� . -..s ?a '2: i✓- 9aK ' �3a5ars �. ..� .,:.xt � FS- 4
-
Total Heating Required Including Ventilation Air: 45,399 Btuh 45.399 MBH
Total Sensible Gain: 13,276 Btuh 70 %
Total Latent Gain: 5,606 Btuh 30 %
Total Cooling Required Including Ventilation Air: 18,881 Btuh 1.57 Tons(Based On Sensible+Latent) j
w
.. -.
Rhvac is an ACCA approved Manual J and Manual D computer program.
Calculations are performed per ACCA Manual J 8th Edition,Version 2, and ACCA Manual D.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at
your design conditions.
I
I
i
I
\\badata\RedirectedFolders...\NJJ The San Fran 2021 SW.rhv Friday, February 19,2021, 3:27 PM
yac Rlasltler�tiat"'blight.Co-�nmetclsl.�tYAGiioads � + ' � 3 klits<�oftv�ra�'t�e�fet Pmgr�,�ni�'%
t3ursville�eattng&AIG lnc 5 ThNesrah
System 1, Zone 1 Summary Loads (Peak Load Procedure for Rooms)
SRI
j bah: Glazing-bah, ground reflectance=0.23, u-value 20 487 0 150 150
0.28, SHGC 0.2
bah: Glazing-bah, ground reflectance=0.23, u-value 48 1,170 0 632 632
0.28, SHGC 0.22
bah: Glazing-bah, ground reflectance=0.23, u-value 25 587 0 201 201
0.27, SHGC 0.24
bah: Glazing-bah, ground reflectance=0.23, u-value 42 987 0 330 330
0.27, SHGC 0.23
hbt: Door-hbt 20.4 266 0 73 73
hbt: Door-hbt 19 232 0 64 64
12F-Osw:Wall-Frame, R-21 insulation in 2 x 6 stud 1334.4 7,546 0 1,153 1,153
cavity, no board insulation, siding finish,wood studs
Subtotals for structure: 11,275 0 3,298 3,298
People: 0 0 0 0
Equipment: 0 1,200 1,200
Lighting: 0 0 0
Ductwork: 1,633 0 852 852
Infiltration: Winter CFM: 9, Summer CFM: 0 828 0 0 0
System 1,Zone 1 Load Totals 13,736 0 5,452 5,452
is ��.^ �xM H`..-. -����x�'��� �`�, ,�;:�..,� 5 •��'"�".'�� '��a, .�' .. �,.. `��:_:��� >.�r � - ��
Supply CFM: 255 CFM Per Square ft.: 0.221
1 Square ft. of Room Area: 1,157 Square ft. Per Ton: 2,546
I� Volume(ft')of Cond. Space 12,149
r'. „xr '' Yv-i y- a*r. v''2'` '` r sa 'a�S .� 3,, . ' .-'•-.,n�„ arY+v
z,��
Total Heating Required. 13,736 Btuh 13.736 MBH
Total Sensible Gain: 5,452 Btuh 100 %
Total Latent Gain: 0 Btuh 0 %
Total Cooling Required 5,452 Btuh 0.45 Tons(Based On Sensible+Latent)
Rhvac is an ACCA approved Manual J and Manual D computer program.
Calculations are performed per ACCA Manual J 8th Edition,Version 2, and ACCA Manual D.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at
your design conditions.
i
I
i
I
i
i
i
i
\\badata\RedirectedFolders ...\NJJ The San Fran 2021 SW.rhv Friday, February 19, 2021, 327 PM
��rac Re�sldential b Light Commarofal HV�►C Loads , • , � Mite Sof/waE+s E�relapme�1n4'"
j Sumsvalte hleabng&d/G Inc v Tae Sam Fran,s
10 X5337
System 9, Zone 2 Summary Loads (Peak Load Procedure for Rooms)
G4W- a
T � G n 7
4
bah: Glazing-bah, ground reflectance=0.23, u-value 47.5 1,156 0 851 851
0.28, SHGC 0.2
bah: Glazing-bah, ground reflectance=0.23, u-value 45.5 1,108 0 403 403
0.28, SHGC 0.22
bah: Glazing-bah, ground reflectance=0.23, u-value 11.6 263 0 221 221
0.26, SHGC 0.24
12F-Osw:Wall-Frame, R-21 insulation in 2 x 6 stud 1108.2 6,265 0 959 959
cavity, no board insulation, siding finish,wood studs
R-49-ad: Roof/Ceiling-Under Attic with Insulation on Attic 1263.4 2,199 0 1,213 1,213
Floor(also use for Knee Walls and Partition
Ceilings), Custom, R49,dark asphalt
' Subtotals for structure: 10,991 0 4,324 4,324
People: 5 1,150 1,500 2,650
Equipment: 400 0 400
Lighting: 0 0 0
Ductwork: 1,572 0 1,103 1,103
Infiltration:Winter CFM: 7, Summer CFM: 0 665 0 0 0 `!
System 1,Zone 2 Load Totals: 13,229 1,550 7,060 8,610 j
" x33' z, w; y `,� q ;a:t " ` ::"'- - ,.a'`•,, a r{ a 1i Vie= 't-,
�x 1
�;:.;
Supply CFM: 331 CFM Per Square ft.: 0.262
Square ft. of Room Area: 1,263 Square ft. Per Ton: 1,760
Volume(ft3)of Cond. Space 10,107
I .. s+yy •. -E .2 ' d 'S Y Lt,Y Rn.. qSh L Y dK�^.i, sv' .t �i �-k u Gy G`M1y"�r ^^
i �� ', 'ie�:'�y.",+c, ^Y�� x�..._` ,'�'...� ��m �>fi'�i'�,ku�"..,ry a.����� ..�(.'rr�i.�•uc`_'. ._ ��"�. ;. .` .,_ �'s:i�,"�z.�3...-..:�"'.. .�'.�'�,h��,7'�-�"�?`z�, .mtr°£.'°�'c�'-�c'"t,�:i'
Total Heating Required: 13,229 Btuh 13.229 MBH
Total Sensible Gain: 7,060 Btuh 82 %
Total Latent Gain: 1,550 Btuh 18 %
Total Cooling Required: 8,610 Btuh 0.72 Tons(Based On Sensible+ Latent)
Rhvac is an ACCA approved Manual J and Manual D computer program.
Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at
I your design conditions.
I �
I
I
i
i
i
i
I
i
I
\\badata\RedirectedFolders...\NJJ The San Fran 2021 SW.rhv Friday, February 19,2021, 3:27 PM
�Rhvala Resldantfal&Light,Gammp�ml MVAC Loads' ,F . -� � Eliba Softvus�,t��etdprn� J�i�::
i Bumsvill�I�ea'pn�,�luG Inc - qtr 1��f � San
Bumswlle,MN-533'7 _: ,,,• � ��-�r� ..:� v Pa 8 f9
I S stem 7, Zone 3 Summa r y Loads (Peak Load Procedure for Rooms
bah: Glazing-bah, ground reflectance=0.23, u-value 35 852 0 274 274
0.28, SHGC 0.22
bah: Glazing-bah, ground reflectance=0.23, u-value 42 987 0 330 330
0.27, SHGC 0.23
12F-Osw:Wall-Frame, R-21 insulation in 2 x 6 stud 453 2,560 0 392 392
cavity, no board insulation, siding finish,wood studs
15BO-15sf-8:Wall-Basement, , R-15 board insulation to 800 2,923 0 0 0
floor, no interior finish, 8'floor depth
21A-20-v: Floor-Basement, Concrete slab,any thickness, 1200 2,819 0 0 0
2 or more feet below grade, no insulation below floor,
vinyl covering, shortest side of floor slab is 20'wide
Subtotals for structure: 10,141 0 1,228 1,228
People: 0 0 0 0
Equipment: 0 0 0
Lighting: 0 0 0
Ductwork: 1,407 0 232 232
Infiltration:Winter CFM: 3, Summer CFM: 0 290 0 0 0
System 1,Zone 3 Load Totals: 11,838 0 1,489 1,489
I a�:
Supply CFM: 70 CFM Per Square ft.: 0.058
Square ft. of Room Area: 1,200 Square ft. Per Ton: 9,674
Volume(ft')of Cond. Space: 11,400
Total Heating Required: 11,838 Btuh 11.838 MBH
Total Sensible Gain: 1,489 Btuh 100 %
Total Latent Gain: 0 Btuh 0 %
Total Cooling Required: 1,489 Btuh 0.12 Tons(Based On Sensible+Latent)
�Rhvac is an ACCA approved Manual J and Manual D computer program.
Calculations are performed per ACCA Manual J 8th Edition,Version 2, and ACCA Manual D.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at
your design conditions.
I
i
i
I
i
I
i
\\badata\RedirectedFolders...\NJJ The San Fran 2021 SW.rhv Friday, February 19, 2021, 3:27 PM
Rhvac Ragitl®n�tial iii Light Commercial HVAC t oatls EIiGe SoDeveioprt�ent,�l�c
t$umsvllle�1eang
�` T� ?he Seri Ftan
,.:: .•_: ^ ,., .. � ,, .._,. .� !Iia �X32-
�Biims�llle„IV1N 5b337- � _ ;
j Detailed Room Loads Room 17 Basement (Peak Fenestration Gain Procedure)
, zfi u `Sr,Ft ib"" .oma y a ;
3dw'��Z.., aiY.SL�•c�a�v�r� �
Room is in zone 3,which peaks at 3 pm
Calculation Mode: Htg. &clg. Occurrences: 1
Room Length: 30.0 ft. System Number: 1
Room Width: 40.0 ft. Zone Number: 3
Area: 1,200.0 sq.ft. Supply Air: 70 CFM
Ceiling Height: 9.5 ft. Supply Air Changes: 0.4 AC/hr
Volume: 11,400.0 cu.ft. Req. Vent. Clg: 0 CFM
Number of Registers: 1 Actual Winter Vent.: 59 CFM
Runout Air: 70 CFM Percent of Supply.: 84 %
Runout Duct Size: 5 in. Actual Summer Vent.: 20 CFM
Runout Air Velocity: 511 ft./min. Percent of Supply: 29 %
Runout Air Velocity: 511 ft./min. Actual Winter Infil.: 3 CFM
Actual Loss 0.210 in wg/100 ft Actual Summer Infil 0 CFM
I &. 'x Ys t jfJ"e� _ t
� a �,��a os[,:r c��� s�ns.�Asx '`fi
� �
N-Wall-12F-Osw 40 X 8 243 0.065 5.7 1,374 0.9 0 210
! S-Wall-15BO-15sf-8 40 X 8 320 0.042 3.7 1,169 0.0 0 0
E-Wall-15BO-15sf-8 30 X 8 240 0.042 3.7 877 0.0 0 0
W-Wall-1 5BO-1 5sf-8 30 X 8 240 0.042 3.7 877 0.0 0 0
j N-Wall-12F-Osw 40 X 1.5 60 0.065 5.7 339 0.9 0 52
S-Wall-12F-Osw 40 X 1.5 60 0.065 5.7 339 0.9 0 52
E-Wall-12F-0sw 30 X 1.5 45 0.065 5.7 254 0.9 0 39
W-Wall-12F-0sw 30 X 1.5 45 0.065 5.7 254 0.9 0 39
N-GIs-bah shgc-0.22 O%S(2) 35 0.280 24.4 852 10.7 0 376 j
N-GIs-bah shgc-0.23 0%S 42 0.270 23.5 987 11.0 0 460
Floor-21A-20 40 X 30 1200 0.027 2.3 2,819 0.0 0 0
Subtotals for Structure: 10,141 0 1,228
Infil.: Win.: 3.1, Sum.: 0.0 530 0.547 290 0.000 0 0
Ductwork: 1,407 232
AED Excursion: 28
Room Totals: 11,838 0 1,489
I
I
I
\\badata\Redirected Folders...\NJJ The San Fran 2021 SW.rhv Friday, February 19, 2021, 3:27 PM
Rh!�vale Res: ehtial&Light CornmerciaT HVAC Loads: EI1fe Software T�velopmenT,Irte
T
Bur�rsv111p Heahng.8 A!C Inc h The Sari Fran '
f 13umsv�lie,TlN'a�'5337
z
- - - - ---------------- --- ---
S stem? Room Load Summary
--- �v----_ -�-- ---- ---
1 Y rY
� 3rr5'g'�`'s'y�''i as�yr�..'yXf "xa„�_� ':-r,€ §, � �.,�4,��r�". ,x Via. &� �4�. ��y ., •„^"F �A:�'� .:.:'j
j --Zone 1-
1 Foyer 149 1,379 18 1-3 349 366 0 17 17
2 Study 120 1,945 26 1-4 333 619 0 29 29
3 Great Room 320 3,592 48 1-5 309 898 0 42 42 j
! 4 Dining 160 1,590 21 1-3 547 573 0 27 27
5 Kitchen 192 1,775 24 1-5 628 1,827 0 86 86
6 Mud Room 108 2,657 36 1-4 564 1,050 0 49 49
1 7 Powder Room 108 798 11 1-2 255 119 0 6 6
Zone 1 subtotal 1,157 13,736 184 5,452 0 255 255
--Zone 2--
8 Bedroom 2 158 2,103 28 1-5 545 1,587 230 74 74
9 Wic 36 747 10 1-2 305 142 0 7 7
10 Bedroom 3 192 1,988 27 1-4 515 960 230 45 45 1
11 Bath 1 78 470 6 1-2 297 138 0 6 6 j
12 Stairs 112 724 10 1-2 731 341 0 16 16 i
13 Laundry 93 813 11 1-3 413 433 400 20 20
14 Master Bedroom 230 2,803 38 1-6 478 2,005 460 94 94 !
15 Master Bath 190 2,056 28 1-3 552 578 0 27 27
16 Bedroom 4 174 1,524 20 1-4 471 876 230 41 41
Zone 2 subtotal 1,263 13,229 177 7,060 1,550 331 331
--Zone 3--
17 Basement 1,200 11,838 158 1-5 511 1,489 0 70 70
Zone 3 subtotal 1,200 11,838 158 1,489 0 70 70
Ventilation 6,596 879 3,708
Duct Latent 348
System 1 total 3,620 45,399 519 13,276 5,606 581 581
System 1 Main Trunk Size: 9x13 in.
Velocity: 715 ft./min
Loss per 100 ft.: 0.103 in.wg
Note: Since the system is multizone, the Peak Fenestration Gain Procedure was used to determine glass sensible gains
at the room and zone levels, so the sums of the zone sensible gains and airflows for cooling shown above are not intended
j to equal the totals at the system level. Room and zone sensible gains and cooling CFM values are for the hour in which
the glass sensible gain for the zone is at its peak. Sensible gains at the system level are based on the"Average Load
Procedure+Excursion"method.
a z'
mi Fa _
Net Required: 1.57 70%/30% X 13,276 5,606 18,881
I
I
j
I
I
I
i
I
j
j
\\badata\RedirectedFolders...\NJJ The San Fran 2021 SW.rhv Friday, February 19,2021, 3:27 PM
City Inspection Dept. Copy _
EAGAN
City Forester Copy
Applicant/Builder Copy
INDIVIDUAL RESIDENTIAL LOT
TREE PRESERVATION PLAN SUMMARY
CITY OF EAGAN FORESTRY DIVISION
651-675-5300
(BUILDER, PLEASE READ ATTACHMENTS)
Development Summerbrooke
Lot Number 23 Block Number 1
Address 774 Summerbrooke Court
Builder Eternity Homes
Phone Number: 651-460-3043
Contact: Ann Hamman
Tree Protection Requirements:
Tree Protection Fencing to be Installed on Site (Orange Poly Fence)
Oak Tree Pruning (Immediately seal wounds during April 1 to July 31)
Therapeutic Pruning Required
X Retaining Wall Installed, No Additional Protection required
Other:
Replacement Trees:
Not Required:
X As Follows: One(1) Category A trees (>=4.0" caliper deciduous
trees). Per approved Tree Mitigation Plan one red oak tree to be
installed in front yard following construction.
Attachments:
X Yes (Refertoattach u S EQRESTRY DIVISION
No REVIEWED
Additional Notes: BY
DATE_9� .______,,....
TREE PRESERVATION PLAN REVIEW— INDIVIDUAL LOT EAGAN
Date Building Permit Application Received 9/13/2021
Development Summerbrooke Lot 23 Block 1
Site Address 774 Summerbrooke Ct
Builder Eternity Homes Contact Ann Hamman
Telephone 651-460-3043 E-mail draftingeternityhomesllc@gmail.com
Property/Lot Owner Name -
Telephone - E-mail -
Office Plan Review—Date 9/21/2021 Notes This permit was previously issued 11/21/18.
The re-issuance of this permit includes a carryover mitigation requirement of one tree to be planted
in the front yard area post construction. Per the approved mitigation plan the trees are identified as
(1) Red Oak(see attached planting plan)
Tree Preservation Data Original Plan Revised Plan
Total Significant Woodland Area sq.ft sq.ft
Total Significant Trees
Woodland To Be Removed sq.ft sq.ft
Trees To Be Removed
Allowable Woodland Removal (20%) sq.ft sq.ft
Allowable Tree Removal(20%)
Required Mitigation YES (or) NO
Calculated Mitigation Amounts
Original Plan- Category A Category B Category C
Revised Plan- Category A Category B Category C
Site Inspection—Date 9/21/2021 Notes five (5) Mitigation trees were installed in 2018:
including five (5) Black Hills Spruce. Previously planted mitigation trees are protected via retaining wall, no
additional tree protection is required. Home Location staked, OK to proceed
G:\Forestry\TreePreservation\Tree Preservation Plan Review-Individual Lot.docx
Original Tree Preservation Plan Approved—Date 11/21/2018 By GH
Forwarded to Inspections—Date 9/24/2021 By AS
Discussion/Meetings with Builder/Owner- Notes
Revised Tree Preservation Plan Approved—Date By
Forwarded to Inspections—Date By
Additional Field Inspections
Date Notes
Date Notes
Date Notes
Date Notes
G:\Forestry\TreePreservation\Tree Preservation Plan Review-Individual Lot.docx
Y
N K N ^
N !� O
^ N 1h
ZBIb OOZb
4�7a N
A1'I�` P�pGE
8004- a
00
w SEER 4183 LS Ib l6lb � Cl
0 00
O U 15 M r N
/N
mry
N
^ N
W N O
Q
CW 0
G Q
Y
C 1 J
G � 1 N
C
n ^ O
//l U
V, y 0
C
O n N O
� Z
M m
co co S
3 Q
r N N
U
n
Ol co
coN
N
N
^ N
egg S6� N
0�
O
N
0�
O
v Aga
909 Z08 798
ro
ADDRESS: 774 SUMMERBROOKE COURT CERTIFICATE OF SURVEY
FOR
ETERNITY HOMES LLC
—
SUMMERBROOKE COURT
i3fNCY A R a+ „ i,C
N89°44'46 65.00
gu,
NOTE.'ALL BUILDING
J I DIMENSIONS ARE SHOWN TO
x -$ fil OUTSIDE OF FOUNDATION
s".,) I 1 WALL
s Ir v?'-`
fig?re.�`at.Nc wv
GARAGE " ae vrcc snRr.,
vor,->rc eurc ),
S Y I M'tN s�l
xy."t x Mf`l
40. � ago I a„s LOT AREA = 9.630 SO. FT.
rn I PROPOSED o HOUSE AREA = 1,837 SO. FT
N 2-S'R)RY PORCH AREA = 120 SO. FT
00 _ I - FB/FLAT - I OD SIDEWALK= 38 SO. FT,
k.c
DRIVEWAY= 814 SO. FT.
IMPERVIOUS = 2,809 SO. FT
sC3
- _ 00
}.
a
Bao +c: C
93aXywu . "h �. q?db y,59 a»„
xoT; l a x�isn
LOT 23 n)9�
— —BLOCK i _ V=20'
N89°57'00"W 65.00
SETBACKS
FRONT-30'
SIDE-ALONG RIGHT OF WAY= 30'
SIDE INTERIOR = 10'ON R-1 (R-1 is
lots over 12,000 sf)
SIDE INTERIOR ON R1-5= 6'
SIDE ON GARAGE = 5'
REAR = 15'
NOTE:ANY LMNG SPACE/S CONSIDERED
THE HOUSE SETBACK, NOT THE GARAGE
SETBACK
® DENOTES MAILBOX
O DENOTES IRON PIPE MONUMENT SET
NOTE: LOWEST OPENING = 936.4
DENOTES FOUND IRON PIPE MONUMENT
�-- DENOTES PROPOSED DRAINAGE DIRECTION NOTE.ADD i EXTRA STEP BETWEEN HOUSE AND GARAGE.
{� DENOTES SERVICE LOCATION
O 935.
DENOTES WOOD HUB PROPOSED TOP OF WALL EEEV. = 99 J5.
!I PROPOSED G4R9GE FLOOR ELEV. 5
M0.0 DENOTES EXISTING ELEVATION PROPOSED BASEMENT FLOOR ELEV. = 928.7
® DENOTES PROPOSED ELEVATION
7-YAr- DENOTES EXISTING CONTOUR
PROPERTY DESCRIP110N
DENOTES DECIDUOUS TREE LOT 23,BLOCK 1,SUMNTERBRWKE,CITY OF
EAGAN.DAKOTA COUNTY,MINNESOTA.
DENOTES EVERGREEN TREE
Bohlen I HEREBY CERTIFY THAT THIS SURVEY WAS PREPARED BY ME OR
DENOTES BITUMINOUS SURFACE Surveying Associates UNDER MY DIRECT SUPERVISION AND THAT I AMA DULY LICENSED
LAND SURVEYOR UNDER THE LAWS OF THE STATE OF MINNESOTA.
31432 +892 CIM R_-
DENOTES CONCRETE SURFACE NwthfWd.MN 5505] numsvilb,mN`.0 M7 Th
__ T/�r ___-
rnono:f5orlsabnsa A almn;,)89so21z DATE: 7-31-2021 IfWI'Wa J. U Ix.rLW.
lumaaraggWhlenxwveyigsun Fax:1952)8969259 THOMAS J.OWEARA,LAND SURVEYOR
DI\01'Ec CIRAVF1 SURFACE MINNESOTA LICENSE NO.46167
S:lProjtctsLagan?summcrbrookc`ulwgUo(23b)kl- n-7-31 2LAwg 7/3V202I 2:59:06 PM('I)1'
MITIGATION PLANTING PLAN
t i f
M / (1) Required
Front Yard Trees ,
SUMMERIBROC
{
i
I 22
21 23 24 25
I
ky Mei
Five(5)Spruce Installed 2018
PLANTING SCHEDULE
KEY I COMMON NAME SCIENTIFIC NAME
OVERSTORY TREES
AUTUMN BLAZE MAPLE/ACER X FREEMANII
0 HACK BERR Y/CELTIS OCCIDENTALIS
O5 SENTRY LINDEN/TILIA AMERICANA 'SENTRY
RED OAK/QUERCUS RUBRA
4 , RIVER BIRCH/BETULA NIGRA
��✓ SCAMP WHITE OAK/QUERCUS BICOLOR
EVERGREEN TREES
V WHITE PINE/PINUS STROBUS
BLACK HILLS SPRUCE/PICEA GLAUCA DENSATA
LOT SURVEY CHECKLIST FOR RESIDENTIAL
BUILDING PERMIT APPLICATION
PROPERTY LEGAL: Lot 23, Block 1, Summerbrooke
DATE OF SURVEY: 7/31/21
LATEST REVISION:
m
c
ra
U
YO z a DOCUMENT STANDARDS
❑✓ ❑ ❑ • Registered Land Surveyor signature and company
❑� ❑ ❑ • Building Permit Applicant
❑✓ ❑ ❑ • Legal description
❑✓ ❑ ❑ • Address
❑✓ ❑ ❑ • North arrow and scale
❑✓ ❑ ❑ • House type(rambler,walkout,split w/o, split entry, lookout, etc.)
❑✓ ❑ ❑ • Directional drainage arrows with slope/gradient%
❑✓ ❑ ❑ • Proposed/existing sewer and water services&invert elevation
❑r ❑ ❑ • Street name
❑✓ ❑ ❑ • Driveway(grade&width-in RAN and back of curb, 22' max.)
❑✓ ❑ ❑ • Lot Square Footage
✓❑ ❑ ❑ • Lot Coverage
ELEVATIONS
Existin
❑✓ ❑ ❑ • Property corners
❑✓ ❑ ❑ • Top of curb at the driveway and property line extensions
❑✓ ❑ ❑ • Elevations of any existing adjacent homes
❑✓ ❑ ❑ • Adequate footing depth of structures due to adjacent utility trenches
❑ ❑✓ ❑ • Waterways(pond, stream,etc.)
Proposed
❑ ❑ • Garage floor
✓❑ ❑ ❑ • Basement floor
❑i ❑ ❑ • Lowest exposed elevation(walkout/window)
❑✓ ❑ ❑ • Property corners
❑D ❑ ❑ • Front and rear of home at the foundation
Yes . PRV Required
PONDING AREA(if applicable)
❑ ❑✓ ❑ • Easement line
El ❑ • NWL
❑ ✓❑ ❑ • HWL
❑ ✓❑ ❑ • Pond#designation
❑ ❑✓ ❑ • Emergency Overflow Elevation
❑ ❑✓ ❑ • Pond/Wetland buffer delineation
No . Shoreland Zoning Overlay District
No • Conservation Easements
DIMENSIONS
✓❑ ❑ ❑ • Lot lines/Bearings&dimensions
✓❑ ❑ ❑ • Right-of-way and street width(to back of curb)
✓❑ ❑ ❑ • Proposed home dimensions including any proposed decks, overhangs greater than 2', porches,etc.
(i.e. all structures requiring permanent footings)
❑✓ ❑ ❑ • Show all easements of record and any City utilities within those easements
✓❑❑ ❑❑ ❑❑ • Setbacks of proposed structure and sideyard setback of adjacent existing structures
• Retaining requirements:
uirements:
4
Reviewed By: Dave Westermayer Date 9/14/21
G:/1 Engineering/Forms/Cert.of Survey Checklist Fillable 03-16-2021
ADDRESS: 774 SUMMERBROOKE COURT CERTIFICATE OF SURVEY
r
3:1 Maximum Slopes FOR
PAN. � � � ��� w� ETERNITY HOMES LLC
PAquWW
CENTERLINE
SUMMERBROOKE COURT
,n CONCRETE CURBS GUTTER. N
g522 9523 q52� g5 A "o ■NST �� �
BENCHMARK: � N89041'40"W 65.00 PERIMETER
% 952 6 g525 952 A 95\2
X325 CURB
o STOP o
93\3
q5\9® UTILITY
X BOXE5
5 PROP05ED 9i
DRIVEWAY o� �5 NOTE.- ALL BUILDING
8.3% I DIMENSIONS ARE SHOWN TO
I OUTSIDE OF FOUNDATION
xg552 Sa s I WALL
95 ' x g32 9525 95\"1
am. 1 8.00 35.5 935.3 '28.00_
o 5x19.0 ---- ----
m g52
.0 N �, --
% 0 932
°` 9522 g520 �k
NOTE:MAILING MAY
GARAGE BE NECE55AP.Y,
N NOTE:ADD I EXTRA N
2 STEP BETWEEN 0
xg5y. 2x 1 x HOUSE AND GARAGE 20.0
iv m
_ 10
952' E 952 520 PORCH
f 4.0, _. . _. 20.0 95\5 LOT AREA = 9,630 SQ. FT.
rn PROPOSED o HOUSE AREA = 1,837 SQ. FT.
C M 2-STORY PORCH AREA = 120 SQ. FT
00
FB/FLAT o 6.01 moi' SIDEWALK = 38 SQ. FT.
r DRIVEWAY = 814 SQ. FT.
6.0 N
M I IMPERVIOUS = 2,809 SQ. FT.
a,
9322x Oo 95.2F3 95\9 xg32� ��i N = 29.179
N _ �I 7.00 40.0 11L8.0 P -002'CANT 935.0 I r
o q52� 935.9 WW_x 931. :.. WW o
O x g52U +9f -- O
li
0 CD
3
/� ^x q55. 45 x q52 6--� it
/ O 9,46 954'
% b� 56c0 5ET5ACKUNE
95 ' 95 RETAINIING\A/ALL`95" 9)4 955 a
5 9
93),94p� 9392 93j8 9552 q55 9566 955 x 9 9 Y.
x
a
S LOT x23 x6 o
,59• •,5 ' 95 8
5 L — —BLOCK 1 =3aa 5 1" = 20'
O _DRAINAGE S UTILITY O
Z' EA5EMENT
_�g463 9453 9g41 / x9422 94\6
N89°57'00"W 65.00
SETBACKS
FRONT-30'
SIDE—ALONG RIGHT OF WAY = 30'
SIDE INTERIOR = 10' ON R-1 (R-1 is
lots over 12,000 sf)
SIDE INTERIOR ON R 1—S = 6'
f r7 �°� SIDE ON GARAGE = 5'
p ' REAR = 15'
B,. NOTE.- ANY LIVING SPACE IS CONSIDERED
y THE HOUSE SETBACK, NOT THE GARAGE
SETBACK
0 DENOTES MAILBOX EAGAN LNGLN"jQ\(j Ut;et
O DENOTES IRON PIPE MONUMENT SET NOTE.- LOWEST OPENING = 936.4
DENOTES FOUND IRON PIPE MONUMENT
�— DENOTES PROPOSED DRAINAGE DIRECTION NOTE.• ADD 1 EXTRA STEP BETWEEN HOUSE AND GARAGE.
rr,} DENOTES SERVICE LOCATION
PROPOSED TOP OF WALL ELEV. = 936.4
0 DENOTES WOOD HUB PROPOSED GARAGE FLOOR ELEV, = 935.5
000.0 DENOTES EXISTING ELEVATION PROPOSED BASEMENT FLOOR ELEV. = 928.7
000.0 DENOTES PROPOSED ELEVATION
OOo— DENOTES EXISTING CONTOUR PROPERTY DESCRIPTION
0112,3 DENOTES DECIDUOUS TREE LOT 23,BLOCK 1,SUMMERBROOKE,CITY OF
EAGAN,DAKOTA COUNTY,MINNESOTA.
DENOTES EVERGREEN TREE
Bohlen I HEREBY CERTIFY THAT THIS SURVEY WAS PREPARED BY ME OR
DENOTES BITUMINOUS SURFACE UNDER MY DIRECT SUPERVISION AND THAT I AM A DULY LICENSED
Surveying & Associates LAND SURVEYOR UNDER THE LAWS OF THE STATE OF MINNESOTA.
31432 Foliage Avenue 1682 Cliff Road E.
DENOTES CONCRETE SURFACE Northfield,MN 55057 Burnsville,MN 55337 DATE: 7-31-2021 Thor"
JT O ZZVV_L
Phone:(507)645-7768 B A Phone:(952)895-9212 THOMAS J.O'MEARA,LAND SURVEYOR
tomeara@bohlensurveying.com Fax:(952)895-9259
DENOTES GRAVEL SURFACE MINNESOTA LICENSE NO.46167
S:\Projects\Eagan\summerbrookc\dwg\Iot23blk1-cert-7-31-21.dwg 7/31/2021 2:59:06 PM CDT
--------------------------
For Office Use
jEAGAN IStormwater Management Permit#: T 3 2 S I
Building Permit#:
- 2 3
�1 Escrow Deposit: 3) 0 0 0 I
3830 PILOT KNOB ROAD I EAGAN, MN 55122-1810 I I
(651)675-5300 1 waterresQcityofeapan.com
Staff:
-------------------------J
STORMWATER MANAGEMENT PERMIT Cr
Date: �- 1 � Site Address:
774 Summerbrooke Ct SFS
Descriptio n of Project: New Residential Single Family Home
Area of Land Being Disturbed: Start Date N/A Completion Date: N/A
❑ Please submit a Land Disturbance and Stormwater Pollution Prevention Plan with this application.
Name: Eternity Homes LLC phone 651 -460-3043
Address/City/Zip:
425 3rd St, Farmington
Property Owner
Contact: Ann Hamman Email: draftingeternityhomesllc@gmail.com
Applicant is: _Owner Contractor
Name: Eternity Homes LLC License#: BC638704
Address: 425 3rd St City: Farmington
Contractor
State: MN Zip 55024 Phone: 651-460-3043 I
Ann Hamman draftingeternityhomesllc@gmail.com
I Contact: Email:
t
Erosion and Sediment Control Performance Security
The City requires an escrow deposit to secure performance of erosion and sediment control(ESC)requirements, including proper
installation and maintenance. The security shall pay for any City costs or expenses to bring the site into compliance with the
stormwater management permit, including any engineering, legal, or administrative expenses; inspections; and necessary work by
City contractor(s). The City may extract from the security escrow. The escrow deposit will be released only upon inspection and
written notice of conformance by the City.
The following escrow deposits include two(2)required City inspections, initial and final.
Existing Single-Family Residential Lot(addition,demolition, pool, retaining wall,etc.) $1,000/lot
New Single-Family Construction $3,000/lot
Multi-Family or Commercial Construction(new,addition,demolition) $5,000/acre*
*Maximum of$12,000
Erosion and Sediment Control Reinspection Fee(for as needed City reinspections after the two(2) included) $85/trip
Security Amount: 37000
The applicant assumes all responsibilities for installation and maintenance of pollution prevention practices on this site.
Any violations of City Code identified by the City shall be addressed within 48-hours of service of the notification.
The applicant understands that failure to maintain pollution prevention practices within the time allotted by the City
notification,will result in enforcement action to correct site deficiencies that are in violation of Sec. 4.34.
The issuance of this permit constitutes a right-of-entry of the City or its contractors to enter upon the construction site for
the purpose of completing ordinance enforcement and/or completing corrective work.
I hereby acknowledge that this information is complete and accurate;that the work will be in conformance with the
ordinances and codes of the City of Eagan; that I understand this is not a permit, but only an application for a permit, and
work is not to start without a permit;that the work will be in accordance with the approved plan in the case of work which
requires a review and approval of plans.
The undersigned accepts full responsibility for compliance with the Stormwater Management Ordinance of the City of
Eagan and agrees to comply with the Stormwater Pollution Prevention Plan or equivalent in full.
X Coral Ozmun X ✓
Applicant's Printed Name Applicant's Signat e
Performance Security Release
The following information will determine to whom the esc,ow deposit will be returned. Security will be returned in the form
of a check.
Name: Eternity Homes LLC
Address/City/Zip:
Phone: Email:
Amount: Permit Number
FOR OFFICE USE ONLY
SUB TYPE WORK TYPE
X Stormwater Management Permit Apartments Commercial/Industrial
Multi Family Public Facility
Single Family
DESCRIPTION
X Addition Demolition Pool
X New Retaining Wall Other:
REQUIRED INSPECTIONS
Initial Inspection
Final Inspection
SECURITY
Erosion and Sediment Control Deposit(6501.2257) $3.,000
Other: _
Total: $3,000
"''�� 10/15/2021
Reviewed By: Water Resources Date:
ADDRESS: 774 SUMMERBROOKE COURT &AA4 CERTIFICATE OF SURVEY
FOR
ETERNITY HOMES LLC
CENTEKLINt
SUMMERBROOKE COURT
N CONCRETE CURB d GU N
g522 9323 93211 q5`A g3p'I
BNn`r935RK3� N89041'40"W 65.00
% 932.6 9325 93'-a 931 L _
932 URB 931-1
o I TOP o
urluTY CLtP-VEb 4P S�PE-
_ I 93 •
BOXES
5 PK0P05E1) ��n
DRIVEWAY of s Aou) NOTE. ALL BUILDING
B 3%
ml Stockpile/
I Storage area DIMENSIONS ARE SHOWN TO
OUTSIDE OF FOUNDATION
WALL
% 9336 Ir %9325 I qy2s�`-
--------------
8.00 /J
% N 93Z 0
NOTE:&LING MAY
7.0GARAGE BE NECE55ARY
' �
T N NOTL:ADD I txrpA N
5TEP BETWL'EN
%9j2✓ % HOU51'AND GARAGE -
% 20.0 0
"0 POKCII �p°�
4.0 _ OM1PO.0 9315 LOT ARE4 = 9,630 SQ. FT.
Cn PROPOSED 0 HOUSE AREA = 1,837 SQ. FT.
2-STORY
N I N m I PORCH AREA = 120 SQ. FT.
06 FB/FLAT o 5.01 co SIDEWALK = 38 SQ. FT
O r DRIVEWAY = 814 SQ. FT.
G.0 N
0
IMPERVIOUS = 2,809 SQ. FT.
9iti2 " 29.179
7 C14
___I 7.00_ 40.0 .0 �p
00 r
2'CANT
0 % !LT rE G�)I.c.r=-
o M I 932 935.9 bVW _931.Sx...WW 0 o ....
O % g32p +'l O
8 U) ��D SilJli
9
/••� ^x qj53 .,9353 a %43g —� I .' 9326_:.
/ _� 46 9546 ^ - i77 5 q3% L`t
L L 935. ( 934,
935 6 X 9.15
50 SACK LINE _
936, 935.
RETAKING WALL (ST-I '/gf1
g39x9App 9,192 03j8 933' Y.
9366 g359 9%g364 t-']
Vt`
:;393 LOT 23 3a° A bb ;,�� 1IV, �
5 — BLOCK 1 — ,,g9 5 t/ .�-- '�� 1" = 20'
— — — AIK
O ORAINAGE L UTILI�' O_
i'^--EASEMENT
946:1 9451 q44, %y422 9AtiA
N89057'00"W 65.00
_ SETBACKS
Erosion and Sediment control maintenance schedule: FRONT—.30'
• -within 24-hours,remove any sediment build-up on perimeter control Final Stabilization Plan: SIDE—ALONG RIGHT OF WAY = 30'
devices exceeding 1/3 of the device height or storage capacity. SIDE INTERIOR = 10' ON R-1 (R-1 is
• Within 24-hours maintain or replace any non-functioning pollution pre- Apply Perennial Rye grass seed lots over 12,000 Sf)
vention devices or practices. @ 9-10lbs/1,000 sqft. SIDE INTERIOR ON R1—S = 6'
• Within 24-hours remove any deposited sediment,debris,or trash from Will stabilize with hydraulically SIDE ON GARAGE = 5'
adjacent properties,streets,or sidewalks following discovery. applied mulch. REAR = 15'
• Within 14-days after land disturbing activities have ceased,temporarily or to
permanently stabilize exposed soils. NOTE.' ANY LIVING SPACE IS CONSIDERED
THE HOUSE SETBACK, NOT THE GARAGE
SETBACK
QM DENOTES MAILBOX
O DENOTES IRON PIPE MONUMENT SET NOTE.• LOWEST OPENING = 936.4
0 DENOTES FOUND IRON PIPE MONUMENT
�--- DENOTES PROPOSED DRAINAGE DIRECTION NOTE: ADD 1 EXTRA STEP BETWEEN HOUSE AND GARAGE.
DENOTES SERVICE LOCATION Erosion and sediment Control inspection schedule: PROPOSED TOP OF WALL ELEV. = 936.4
p DENOTES WOOD HUB Every 7-days of exposed soil areas, PROPOSED GARAGE FLOOR ELEV. = 935.5
• Within 24-hours of a Y:inch rain event, PROPOSED BASEMENT FLOOR ELEV. = 928.7
000.0 DENOTES EXISTING ELEVATION Every 30-days of areas that are stabilized but construction
000.0 DENOTES PROPOSED ELEVATION activity continues
- • Prior to resuming construction following an extended pause
OOo— DENOTES EXISTING CONTOUR PROPERTY DESCRIPTION
DENOTES DECIDUOUS TREE LOT 23,BLOCK I,SUMMERBROOKE,CITY OF
EAGAN,DAKOTA COUNTY,MINNESOTA.
DENOTES EVERGREEN TREE
Bohlen I HEREBY CERTIFY THAT THIS SURVEY WAS PREPARED BY ME OR
DENOTES BITUMINOUS SURFACE UNDER MY DIRECT SUPERVISION AND THAT I AM A DULY LICENSED
Surveying & Associates LAND SURVEYOR UNDER THE LAWS OF THE STATE OF MINNESOTA.
31432 Foliage Avenue 1682 Cliff Road E.
DENOTES CONCRETE SURFACE Northfield,MN 55057 Burnsville,MN 55337 I
DATE: 7-31-2021
Phone:(507)645-7768 A Phone:(952)895-9212 THOMAS J.O'MEARA,LAND SURVEYOR
.. tomeara@bohlensurveying.com Fax:(952)895-9259
DENOTES GRAVEL SURFACE MINNESOTA LICENSE NO.46167
S:1Projccts\Eagan\summerbrookc\dwg\lot'3blkl-cert-7-31-21.dwg 7/31/2021 2:59:06 PM CDT
PERMIT
City of Eagan Permit Type:Building
Permit Number:EA175722
Date Issued:04/12/2022
Permit Category:ePermit
Site Address: 774 Summerbrooke Ct
Lot:23 Block: 1 Addition: Summerbrooke
PID:10-72950-01-230
Use:
Description:
Sub Type:Fireplace
Work Type:Gas Fireplace (new)
Description:
Census Code:434 - Residential Additions, Alterations
Zoning:
Square Feet:0
Occupancy:
Construction Type:
Comments:Improvements to the home may require smoke detectors in all bedrooms. Chimney / flue must be inspected prior to
concealing.
Carbon monoxide detectors are required within 10 feet of all sleeping room openings in residential homes (Minnesota State
Valuation: 3,000.00
Fee Summary:BL - Base Fee $3K $88.50 0801.4085
Surcharge - Based on Valuation $3K $1.50 9001.2195
$90.00 Total:
I hereby acknowledge that I have read this application and state that the information is correct and agree to comply with all applicable State
of Minnesota Statutes and City of Eagan Ordinances.
Contractor:Owner:- Applicant -
Eternity Homes Llc
425 Third St
Farmington MN 55024
Glowing Hearth And Home Llc
100 Eldorado Dr.
Jordan MN 55352
(952) 492-9276
Applicant/Permitee: Signature Issued By: Signature
PERMIT
City of Eagan Permit Type:Plumbing
Permit Number:EA179728
Date Issued:10/19/2022
Permit Category:ePermit
Site Address: 774 Summerbrooke Ct
Lot:23 Block: 1 Addition: Summerbrooke
PID:10-72950-01-230
Use:
Description:
Sub Type:Water Softener
Work Type:New
Description:
Meter Size Meter Type Manufacturer Serial Number Remote Number Line Size
Comments:Carbon monoxide detectors are required within 10 feet of all sleeping room openings in residential homes (Minnesota State
Building Code).
Please call Building Inspections at (651) 675-5675 to schedule a final inspection.
Fee Summary:PL - Permit Fee (WS &/or WH)$59.00 0801.4087
Surcharge-Fixed $1.00 9001.2195
$60.00 Total:
This permit shall be null and void if work does not start within 180 days of issuance, or if work is suspended for 180 days or more after
started.
I hereby acknowledge that I have read this application and state that the information is correct and agree to comply with all applicable State
of Minnesota Statutes and City of Eagan Ordinances.
Contractor:Owner:- Applicant -
Patrick Foulks
774 Summerbrooke Ct
Eagan MN 55123
(612) 735-0796
Tri County Water Conditioning Inc
325 Third Ave NW
P O Box 65
Huchinson MN 55350
(320) 587-2950
Applicant/Permitee: Signature Issued By: Signature