No preview available
 /
     
4884 Avery Ct 8, tai 7 42 I �G 1-73q5/- loo. 00 ----- t—oo• D I For Office Us e7 �1 Z Permit#: /� / '7 Permit Fee: 0 42 i Date Received: ��✓��`a I I 3830 PILOT KNOB ROAD I EAGAN,MN 55122-1810 I I staff: (651)675-5675 IFAX:(651)675-5694 I 4�� buildinainsaectionsO-citvofeaaan.com —————————————————' /-7-Z y9- Lot 51 13164 q- K" Id, 2021 RESIDENTIAL BUILDING PERMIT APPLICATION Date: 11-12-21 Site Address: 4884 Avery Court Unit#: 5 Name: Pulte Homes of MN Phone: 763-274-9345 ROwnerAddress/City/Zip: tl 7500 Flying Cloud Drive, Eden Prairie, MN 55344 Owner Applicant is: Owner ✓ Contractor Owner Email: CurtiS.johnSon@pultegroup.com Type of Work Description of work: New Residential Construction Construction Cost: 170,006 Multi-Family Building:(Yes X/No Company: Pulte Homes of MN Contact: Contractor Address: 7500 Flying Cloud Drive city: Eden Prairie State: MN Zip: 55344 Phone: Email: ellie.rogers@pultegroup.com License#: BC627723 Certificate Lead ert cafe#: If the project is exempt from lead certification, please explain why: COMPLETE THIS AREA ONLY IF CONSTRUCTING A NEW BUILDING In the last 12 months,has the City of Eagan issued a permit for a similar plan based on a master plan? _Yes V/ No If yes,date and address of master plan: Licensed Plumber: Sabre Phone: (763) 473-2267 Mechanical Contractor: Sabre Phone: (763) 473-2267 Ground Tech 651 964-0006 Sewer&Water Contractor. Phone. Fire Suppression Contractor: FSS Phone: 651-775-3964 NOTE.Plans and supporting documents that you submit are considered to be public Information. Portions of the Information maybe classified as non-public ffyou provide specffic reasons that would ermit the City to conclude that they are trade secrets. You may subscribe to receive an electronic notification from the City of proposed ordinances by signing up for an email update on the City's website at www.citvofeaaan.com/subscribe. CALL BEFORE YOU DIG. Contact Gopher State One Call at(651)454-0002 or www.00i)herstateonecall.org for protection against underground utility damage. Contact Gopher State One Call 48 hours before you intend to dig to receive locates of underground utilities. I hereby acknowledge that this information is complete and accurate;that the work will be in conformance with the ordinances and codes of the City of Eagan;that I understand this is not a permit, but only an application for a permit, and work is not to start without a permit; that the work will be in accordance with the approved plan in the case of work which requires a review and approval of plans. Steve Brock s x X A licant's Printed Name Applicant's Signature PP PP 9 FOR OFFICE USE ONLY Site Address: 4884 Avery Ct Permit#: 173491 SUB TYPES Foundation _ Fireplace _ Porch(3-Season) _ Miscellaneous Single Family _ Garage _ Porch(4-Season) _ Accessory Building _ Multi _ Deck _ Porch(Screen/Gazebo/Pergola) ✓ 01 of 6 Plex _ Lower Level _ Pool WORK TYPES ✓ New _ Repair _ Siding _ Retaining Wall Addition _ Fire Repair _ Reroof _ Move Building Alteration _ Water Damage _ Windows _ Demolish Building* Replace _ Egress Window _ Solar *Demolition of entire building-give PCA handout to applicant DESCRIPTION Calculated Valuation $200,465.67 Occupancy IRC-3 Townhouse MCES System Plan Review Code Edition 2020 MSBC SAC Units 1 (25%_100% ✓ ) Zoning PD City Water ✓ Census Code 101 Stories 2 Booster Pump #of Units 6 Square Feet 1911 PRV ✓ #of Buildings 1 Length Fire Suppression Required ✓ Type of Construction Not Applicable Width REQUIRED INSPECTIONS ✓ Footings(New Building) ✓ Meter Size: Footings(Deck) ✓ Final/C.O. Required Footings(Addition) Final/No C.O.Required ✓ Foundation ✓ Foundation Before Backfill HVAC_Service Test Gas Line Air Test_Hood Roof:_Ice&Water _Final Pool:_Footings —Air/Gas Tests _Final ✓ Framing 30 Minutes ✓ 1 Hour Drain Tile ✓ Fireplace: ✓ Rough In ✓ Air Test ✓ Final Siding:_Stucco Lath ✓ Stone Lath _Brick_EFIS ✓ Insulation Windows ✓ Sheathing Retaining Wall:_Footings_Backfill_Final ✓ Sheetrock ✓ Radon Control ✓ Fire Walls ✓ Fire Suppression: ✓ Rough In ✓ Final ✓ Braced Walls ✓ Erosion Control Stormwater Management ✓ Shower Pan Other: Permit Required: Reviewed By: � —, Building Inspector RESIDENTIAL FEES Calculated Valuation $200,465.67 Base Fee $1,662.75 Plan Review $1,080.79 State Surcharge $100.28 MCES SAC $2,485.00 City SAC $122.10 Utility Connection Charge $1,592.90 S&W Permit&Surcharge $129.00 Treatment Plant $989.60 Radio Read $205.00 Other: 3/4"Meter $300.00 Copies: TOTAL $8,667.42 / -7 Residential Permit Valuation Calculations Site Address: 4884 Avery Ct Project Description: New Townhome 1 of 6, Lot 5, Block 9 Space Type Square Feet Amount per Subtotal Square Foot 3-Season Porch $ 60.00 $ - 4-Season Porch $ 76.00 $ - Basement(New)Unfinished $ 16.50 $ - Basement Finish Addendum (prior to CO) $ 79.23 $ - Basement Finished $ 95.73 $ Bathroom Remodel $ 20.00 $ Bonus Room Finished $ 95.73 $ Bonus Room Remodel $ 20.00 $ - Bonus Room Unfinished $ 35.00 $ - Crawl Space $ 8.00 $ - Deck $ 15.00 $ Drain Tile ($135 set fee) NA Egress Window($2,000 per pit) NA Front Stoop 24 $ 50.00 $ 1,200.00 Garage (attached with footings) 404 $ 40.41 $ 16,325.64 Garage (detached with floating slab) $ 30.00 $ - Kitchen Remodel $ 20.00 $ Lower Level Remodel $ 20.00 $ - 95.73 79 168 .71 Finished 827 , Main Leve e $ $ Room Addition $ 95.73 $ - Rot Repair(per valuation) NA Screen Porch $ 50.00 $ - Screen Porch (aluminum frame) $ 30.00 $ Solar Array(per valuation) NA Sport Court $ 16.50 $ Townhouse $ 87.40 $ - Upper level Finished 1,084 $ 95.73 $ 103,771.32 Upper Level Unfinished $ 35.00 $ - Total $ 200,465.67 +004 A-Ve/lij & - �a-t- .5 , L31 c 4- c) MVacant 31 maximum 410pes 27 o r W81111 WiU A', N, X 142,6 d i - I X 942.4 X 942.4 941-3x 942.7 L N89051'32"E 83.50 II I 941. � (0, 941 zj42.0 X 941.3 X 941.0 A -<<----9'-.<<-----<<---1- 940.9 941.93 *4 Bejichmark-- 0 L0 Benchmark 8.00 Lr� 942.0 A k X 940.9 X 943.7 A -.2 X X 942 1 8 Lc);)A�2 4 7 re) r- 03 10.00 OD 1 12.50 0 4DI ()a 41 1 0 942.5*( 'P r Q) N U -9- ED I c, U) 700 94 < 2.07 //p � 941.69 0-1942 Benchmark Benchmark'� A 'Al /Nowswvzi.E 83.5012.00 do n n 941.4 X 943.5 2.00 Z1 00 1'0 ' r/ 25.0 42 94 - in 0 LO CL 0 Y6.1010 0 0 Ii1I >-94 '80 0.> CD 4. (D 0) C*4 af Ben:�hmark- C4 0-0 cc) 941.72 r1i �/e LLJ CD Benchmark LO > N89 2"E 83.5C�/ao 8.0 0 9 nn 2.no 9*51 X 941.5 X 944.3 < L0 A 10.0 06 0 n . 27 12.50K . Q, E: 9 4 f::o /1- V) 6.00 04 0 - 942.04 r<- M 4 E' Benchmark °O 0 10.00 94 /N '� x 942.QK 943.2 21 M00 I I 89051',32*E 83.502.0 Be hmark-- Z.UU' i 118.00 1 94 X .4 l" > 0 LO r (COI',) 6.00 0 A -20 4.00 11 V CIA:) C4 Y LLI /941 0 / �: 941.91 1.96 12 - C14 9 nchmark.- / ' ' 0) 11 Benchmark 1 00 1 1 2 nn .9 nnN89*51'32*E .50 - 18-OD L X 943.6 1. 83 X 941.9 00 Z.0c I P 1 / 00 X 94 V C104 0y 0 ' 12.50 00 '4C*4 0 0 II U) -E-') '-/ Q) 4.00 942.0 1n 9420 0 6.00 0 9 .0 /F A u7i =03 941.80 lZ 4: 9' 3 �? 11 1 CD i 942.6 �d Benchmark V a- / 1 0 1 .00 18.00, 1 942.04 83.5 - y Bepch mark-- in I ? no /N89751'32"E -- --12.00 X 941.7 X 943.5 / J;� (-C! X 44.7 0 0 U) 6.00 I 94ri E 4.0 00 00 0 / I 1 OR 0-0 1 X 947 M OR 'd Co on C4 941.25 94 28 12.5 0.0 -----------Cq Benchmark Bi-hmark- 1 1 /,7. X 943.3 10.00 5.0 J- =t X 942.2 Lq -- - - - - 000 Ln L6 MAI x 942.<2 UM4 X 943.5 Q.3 -(942 _7=f _ -- - -<<- X 9'1�<- -<<-----<< X-94i 5- X 940.8 X 942.1 X 942.1 A S89°51 X32 W 83.50-x9-42.9X 940.6 X 943.5 X 942.3 X 942.9 X 943.1 X 943.1 y 1 i Vacant i A 0) Denotes iron pipe House elevations (Proposed) As-built 1,6 2,3,4,5 Denotes service Lot area = 4814 SF Lot area = 8016 SFDenotes television box Top Of Foundation Elev. :(944.0) House area = 2656 SF House area = 4924 SF Denotes electric box Garage Slab Elev. ® Door :(943.5) Porch area = 46 SF Porch area = 96 SF Sidewalk area = 98 SF Sidewalk area = 196 SF rmil Denotes telephone box Driveway area = 364 SF Driveway area = 668 SF X 000.00 Denotes existing elevation Patio area = 164 SF Patio area = 332 SF ( 000.00 ) Denotes proposed elevation Total Impervious Area = 3328 SF Total Impervious Area = 6216 SIF Denotes drainage flow direction Impervious Coverage = 69.1% Impervious Coverage = 77.5% A Denotes spike Construction Notes: mmmamom Denotes proposed retaining wall E 11 E D 1. Install rock construction entrance. designed and built by others. 0' 10' 20' 2. Install silt fence as needed for erosion control. Byjnl I 3, Sidewalks shall drain away from house a minimum of 1.0%. 4. Contractor must verify driveway design. Date I Ll� 5. Contractor must verify service elevation prior to construction. 6. Add or remove foundation ledge as required. Scale: 1" 20' 7. Retaining walls are conditional; Wall installed if the grade exceeds 3:1. EAGAN ENG&\ �G VLerl Wall will not be installed if the grade is 3:1 or less. Benchmark: General Notes: Top Nut Hydrant 1. Grading plan by Pioneer last dated 4-2-21 was used to determine proposed We hereby certify to Pulte Group that this survey, plan or Elevation elevations shown herein. report was prepared by me or under my direct supervision, and 2. This survey does not purport to show improvements or encroachments, that I am a duly licensed Land Surveyor under the laws of the except as shown, as surveyed by me or under my direct supervision. State of Minnesota, dated 11/08/21. 3. Proposed building dimensions shown are for horizontal location of structures Revisions: on the lot only. Contact builder prior to construction for approved construction Signed: eer En P.A. 1.)11-10-21 Stalce building plans. 4. No specific soils investigation has been performed on this lot by the surveyor. The suitability of soils to support the specific house proposed is not the BY: ss'o Hawkinson, L, responsibility of the surveyor. easements other than those shown Peter kin 'a fe n.1 no Surveyor 5. This certificate does not purport to show easern Minnesota License No. 42299 email-phawkinson@pioneereng.com on the recorded plot. 6. Bearings shown are based on an assumed datum. Lot 1.2.3,4,5.6 Block 9, P1*NEERe?0nee?ing,P-A- AVERY PINES Certificate of Survey for: CIV ENGINEERS LANDPLANVVRS LANDS[ VEYORS EANDSCAPFARCMMCTS according to the recorded plat thereof Pulte Group 2422 Enterprise Drive Ph.:(651)681-1914 Dakota County, Minnesota 7500 Flying Cloud Drive Ste 670 Mendota Heights,MN 55120 Fax:(651)681-9488 Address: 4868 4872 4876 4880 4884 4888 Avery Court, Eagan, Mn. Eden Prairie,MIN 55344 www.pioneereng.com House Model: Ashton, Ashton, Bowman, Ashton, Bowman, Bowman Elevation: N/A Project#:121194003 Folder#:8557 Drawn by:CWM @ Pioneer Engineering