Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
685 Yankee Doodle Rd - Gopher Resources Mobile Shop Test & Balance Report 2022-03-29
Cana ac '601VI T9 AABC AABC Commissioning Group GOPHER RESOURCES MOBILE SHOP (TAB Report) FIRM: CUSTOMER: SMB of Minnesota AIRTECH THERMEX LLC PROJECT#: 9380 Central Ave 220065 Suite 120 Blaine MN 55434 PROJECT ADDRESS: 685 YANKEE DOODLE ROAD PHONE: EAGAN MN 55121 (763) 398-3284 DATE: FAX: 2022-03-29 (763) 398-3286 CONTACT: Craig Johnson (763.226.6017) CERTIFICATION Mechanical systems have been completely tested and adjusted to their optimum capabilities.Variances from engineering design, outside of specification parameters,have been noted. �a e414'�� � NCF o. �o nc Mark A Cotroneo,TBE,CxA N 6 wA�C n ©Copyright Marcus Global,Inc. yeF.os•oA'bllbo ���4.Co\10oo Cana acg 100111 AABC Commissioning AABC Group LOCATION: PROJECT NUMBER: CONTACT: GOPHER RESOURCES MOBILE SHOP(TAB Report) 220065 Craig Johnson(763.226.6017) 685 YANKEE DOODLE ROAD EAGAN MN 55121 Table of Contents MAKEUP AIR UNIT 3 MAU-1 3 ENERGY RECOVERY UNIT 5 ERU-1 5 EXHAUSTFAN 9 EF-1 9 Page 2 of 10 2022-03-29 Cana acg 1001111 AABC Commissioning AABC Group LOCATION: PROJECT NUMBER: CONTACT: GOPHER RESOURCES MOBILE SHOP(TAB Report) 220065 Craig Johnson(763.226.6017) 685 YANKEE DOODLE ROAD EAGAN MN 55121 MAKEUP AIR UNIT MAU-1 UNIT DATA UNIT MFG CAPTIVEAIRE LOCATION ROOF UNIT MODEL NO Al-IBT-150-15D AREA SERVED WASH BAY 102 UNIT SERIAL NO NOT LISTED AIRFLOW & STATIC PRESSURE Design Actual % Design Actual % TOTAL CFM 800 875 109 TOTAL SP(INCHES WC) - 0.89 MIN OA CFM 800 875 109 EXTERNAL SP(INCHES WC) 0.50 0.31 62 OA DAMPER POSITION(%) 100 SP SET POINT(INCHES WC) - MOTOR Design Actual % Design Actual % MANUFACTURER WEG NOMINAL EFF% 78.2 VOLTS,NAMEPLATE 208 POWER FACTOR% 69.0 VOLTS,ACTUAL 208 BHP 0.39 FLA,NAMEPLATE 1.90 HP,(DESIGNINAMEPLATE) 0.50 0.50 100 AMPS,ACTUAL 1.50 RPM,(DESIGNINAMEPLATE) 1765 1765 100 PHASE 3 FRAME 56 DRIVE Design Actual % Design Actual % MOTOR SHEAVE x BORE DIRECT DRIVE CENTER TO CENTER(INCHES) DIRECT DRIVE MOTOR SHEAVE(%CAPACITY) DIRECT DRIVE FAN RPM SP NOIT 1147 FAN SHEAVE x BORE DIRECT DRIVE SPEED SETTING 39 HERTZ BELT(S) DIRECT DRIVE MALI-1 Page 3 of 10 2022-03-29 Cana acg 100111 AABC Commissioning AABC Group LOCATION: PROJECT NUMBER: CONTACT: GOPHER RESOURCES MOBILE SHOP(TAB Report) 220065 Craig Johnson(763.226.6017) 685 YANKEE DOODLE ROAD EAGAN MN 55121 IMAGES: AIRFLOW&STATIC PRESSURE 0.01 r +0.59 +0.30 O.A.Hamper Open Supply Fan Burner \ O R.A. Damper Closed MAU-11 OUTLETS OUTLETS Name ROOM NO. TYPE SIZE 'W" DVEL DCFM PRE FPM PRE CFM FINAL FPM FINAL CFM % M1-01 WASH BAY 102;M22 DUCT 10 0.545 734 400 920 501 805 439 110 M1-02 WASH BAY 102 DUCT 10 0.545 734 400 901 491 800 436 109 Totals 800 992 875 NOTES: OUTLETS M1-011 DCFM REQUIRED AIRFLOWS ADJUSTED BECAUSE FAN SIZED FOR 800 CFM WITH DESIGN TOTAL AT OUTLETS EQUAL TO 700 CFM.MAU AT MINIMUM SPEED OF 39 HERTZ. MAU-1 Page 4 of 10 2022-03-29 Cana acg 100111 AABC Commissioning AABC Group LOCATION: PROJECT NUMBER: CONTACT: GOPHER RESOURCES MOBILE SHOP(TAB Report) 220065 Craig Johnson(763.226.6017) 685 YANKEE DOODLE ROAD EAGAN MN 55121 ENERGY RECOVERY UNIT ERU-1 UNIT DATA UNIT MFG VALENT LOCATION ROOF UNIT MODEL NO VPRP-210-X-351-C-IXC AREA SERVED MAINTENANCE 101;M22 UNIT SERIAL NO 18603433 SUPPLY AIRFLOW& STATIC PRESSURE Design Actual % Design Actual % TOTAL CFM 3800 4065 107 TOTAL SP(INCHES WC) 2.40 1.57 65 MIN OA CFM 3800 4065 107 EXTERNAL SP(INCHES WC) 0.75 0.47 63 OA DAMPER POSITION(%) 100 SP SET POINT(INCHES WC) - SUPPLY MOTOR Design Actual % Design Actual % MANUFACTURER BALDOR NOMINAL EFF% 89.5 VOLTS,NAMEPLATE 460 POWER FACTOR% 74.0 VOLTS,ACTUAL 460 BHP 2.33 FLA,NAMEPLATE 4.20 HP,(DESIGNINAMEPLATE) 3.00 3.00 100 AMPS,ACTUAL 3.30 RPM,(DESIGNINAMEPLATE) 1765 1765 100 PHASE 3 FRAME 182T SUPPLY DRIVE Design Actual % Design Actual % MOTOR SHEAVE x BORE DIRECT DRIVE CENTER TO CENTER(INCHES) DIRECT DRIVE MOTOR SHEAVE(%CAPACITY) DIRECT DRIVE FAN RPM SP NOIT 1732 FAN SHEAVE x BORE DIRECT DRIVE SPEED SETTING 58.9 HERTZ BELT(S) DIRECT DRIVE ERU-1 Page 5 of 10 2022-03-29 Cana acg 100111 AABC Commissioning AABC Group LOCATION: PROJECT NUMBER: CONTACT: GOPHER RESOURCES MOBILE SHOP(TAB Report) 220065 Craig Johnson(763.226.6017) 685 YANKEE DOODLE ROAD EAGAN MN 55121 RETURN / EXHAUST AIRFLOW & STATIC PRESSURE Design Actual % Design Actual % TOTAL CFM 3800 3814 100 EXTERNAL SP(INCHES WC) 0.75 0.61 81 TOTAL SP(INCHES WC) 1.9 1.30 68 RETURN / EXHAUST MOTOR Design Actual % Design Actual % MANUFACTURER BALDOR NOMINAL EFF% 89.5 VOLTS,NAMEPLATE 460 POWER FACTOR% 74.0 VOLTS,ACTUAL 460 BHP 1.91 3.00 3.00 100 FLA,NAMEPLATE 4.20 HP,(DESIGNINAMEPLATE) AMPS,ACTUAL 2.70 RPM,(DESIGNINAMEPLATE) 1765 1765 100 PHASE 3 FRAME 182T RETURN / EXHAUST DRIVE Design Actual % Design Actual % MOTOR SHEAVE x BORE DIRECT DRIVE CENTER TO CENTER(INCHES) DIRECT DRIVE MOTOR SHEAVE(%CAPACITY) DIRECT DRIVE FAN RPM NOT 1494 SPECIFIED FAN SHEAVE x BORE DIRECT DRIVE SPEED SETTING 50.8 HERTZ BELT(S) DIRECT DRIVE IMAGES: SUPPLY AIRFLOW& STATIC PRESSURE -0.28 -0.34 TEA.u. 10 Not Sh Da Open r Flter Dnmape OAIRIt., � � "Plate'\ HX EBu ner.56 +0.19 ERU-1 Page 6 of 10 2022-03-29 Cana acg 100111 AABC Commissioning AABC Group LOCATION: PROJECT NUMBER: CONTACT: GOPHER RESOURCES MOBILE SHOP(TAB Report) 220065 Craig Johnson(763.226.6017) 685 YANKEE DOODLE ROAD EAGAN MN 55121 NOTES: SUPPLY MOTOR AMPS,ACTUAL AMPS FROM VFD DISPLAY AT 58.9 HERTZ. SUPPLY DRIVE SPEED SETTING 95%SIGNAL. RETURN 1 EXHAUST MOTOR AMPS,ACTUAL AMPS FROM VFD DISPLAY AT 50.8 HERTZ. RETURN 1 EXHAUST DRIVE SPEED SETTING 90%SIGNAL. ERU-11 OUTLETS OUTLETS Name ROOM NO. TYPE SIZE "K" DVEL DCFM PRE FPM PRE CFM FINAL FPM FINAL CFM % ER-1-01 MAINTENANCE;M22 SG 24 x 8 0.819 769 630 890 729 845 692 110 ER-1-02 MAINTENANCE 101 SG 24 x 8 0.819 769 630 858 703 815 667 106 ER-1-03 MAINTENANCE 101 SG 24 x 8 0.819 769 630 851 697 808 662 105 ER-1-04 MAINTENANCE 101 SG 24 x 8 0.819 769 630 847 694 805 659 105 ER-1-05 MAINTENANCE 101 SG 24 x 8 0.819 769 630 862 706 820 672 107 ER-1-06 MAINTENANCE 101 SG 24 x 8 0.819 769 630 899 736 844 691 110 ER-1-07 OFFICE 104;M21 DUCT 6 0.196 102 20 676 132 110 22 108 Totals 3800 4397 4065 NOTES: OUTLETS ER-1-011 DCFM PLAN SHOWS(6)OUTLETS AT 500 CFM EACH=3000 CFM.UNIT SIZED FOR 3800 CFM.ADJUSTED REQUIRED AIRFLOW AT OUTLETS TO 630 CFM.(TYP OF 6) ERU-11 INLETS ERU-1 Page 7 of 10 2022-03-29 Cana acg 100111 AABC Commissioning AABC Group LOCATION: PROJECT NUMBER: CONTACT: GOPHER RESOURCES MOBILE SHOP(TAB Report) 220065 Craig Johnson(763.226.6017) 685 YANKEE DOODLE ROAD EAGAN MN 55121 INLETS Name ROOM NO. TYPE SIZE "K" DVEL DCFM PRE FPM PRE CFM FINAL FPM FINAL CFM % ER-1-11 STORAGE 201;M22 EXH DUCT 12 0.785 828 650 1241 974 914 717 110 ER-1-12 STORAGE 201 EXH DUCT 12 0.785 764 600 1592 1250 733 575 96 ER-1-13 STORAGE 201 EXH DUCT 12 0.785 828 650 934 733 783 615 95 ER-1-14 STORAGE 201 EXH DUCT 12 0.785 828 650 970 761 788 619 95 ER-1-15 STORAGE 201 EXH DUCT 12 0.785 764 600 1656 1300 746 586 98 ER-1-16 STORAGE 201 EXH DUCT 12 0.785 828 650 1379 1083 894 702 108 Totals 3800 6101 3814 NOTES: INLETS ER-1-111 PRE CFM INITIAL READINGS WITH FAN AT 50.8 HERTZ AND OUTSIDE AIR DAMPER AT 35%/RETURN DAMPER AT 65%.(TYP OF 6) ER-1-111 FINAL CFM FINAL READINGS WITH FAN AT 50.8 HERTZ AND 100%OUTSIDE AIR.(TYP OF 6) ERU-11 Summary SUMMARY Name LOCATION TOTAL FPM #OF READINGS AVE FPM SIZE AREA AIRFLOW DUCT SP TRAVERSE ER-1-01-1-06 GARAGE 27472 20 1374 24 3.14 4313 0.19 NOTES: Summary TRAVERSE ER-1-01-1-06 I LOCATION INITIAL TRAVERSE WITH SUPPLY FAN AT 61.2 HERTZ AND OUTSIDE AIR DAMPER AT 35%OPEN AND RETURN DAMPER 65%OPEN. ERU-1 Page 8 of 10 2022-03-29 Cana acg 100111 AABC Commissioning AABC Group LOCATION: PROJECT NUMBER: CONTACT: GOPHER RESOURCES MOBILE SHOP(TAB Report) 220065 Craig Johnson(763.226.6017) 685 YANKEE DOODLE ROAD EAGAN MN 55121 EXHAUST FAN EF-1 UNIT DATA UNIT MFG CAPTIVEAIRE LOCATION ROOF UNIT MODEL NO DR33HFA AREA SERVED WASH BAY 102;M22 UNIT SERIAL NO NOT LISTED AIRFLOW & STATIC PRESSURE Design Actual % Design Actual % TOTAL CFM 800 740 93 INLET SP(INCHES WC) -0.15 DESIGN TSP(INCHES WC) 0.50 DISCHARGE SP(INCHES WC) 0.00 TOTAL SP(INCHES WC) 0.15 MOTOR Design Actual % Design Actual % MANUFACTURER TELCO GREEN NOMINAL EFF% NOT LISTED VOLTS,NAMEPLATE 115 POWER FACTOR% NOT LISTED VOLTS,ACTUAL 115 BHP FLA,NAMEPLATE 4.30 HP,(DESIGNINAMEPLATE) 0.33 0.33 100 AMPS,ACTUAL 1.00 RPM,(DESIGNINAMEPLATE) SP NOIT 1800 PHASE 1 FRAME NOT LISTED DRIVE Design Actual % Design Actual % MOTOR SHEAVE x BORE DIRECT DRIVE CENTER TO CENTER(INCHES) DIRECT DRIVE MOTOR SHEAVE(%CAPACITY) DIRECT DRIVE FAN RPM SP NOIT 1012 FAN SHEAVE x BORE DIRECT DRIVE SPEED SETTING 55% BELT(S) DIRECT DRIVE EF-1 Page 9 of 10 2022-03-29 Cana acg 100111 AABC Commissioning AABC Group LOCATION: PROJECT NUMBER: CONTACT: GOPHER RESOURCES MOBILE SHOP(TAB Report) 220065 Craig Johnson(763.226.6017) 685 YANKEE DOODLE ROAD EAGAN MN 55121 EF-11 INLETS INLETS Name ROOM NO. TYPE SIZE "K" DVEL DCFM PRE FPM PRE CFM FINAL FPM FINAL CFM % E1-01 WASH BAY 102;M22 DUCT 10 0.545 490 267 687 374 445 243 91 E1-02 WASH BAY 102 DUCT 10 0.545 490 267 820 447 470 256 96 E1-03 WASH BAY 102 DUCT 10 0.545 490 267 667 364 442 241 90 Totals 801 1185 740 NOTES: INLETS E1-011 DCFM REQUIRED AIRFLOWS ADJUSTED BECAUSE FAN SIZED FOR 800 CFM WITH DESIGN TOTAL OF 700 CFM.(TYP OF 3) E1-011 PRE CFM INITIAL READINGS AT 84%SPEED. E1-011 FINAL CFM INITIAL READINGS AT 84%SPEED. EF-1 Page 10 of 10 2022-03-29 e nfi n — a `.■wi - AABC Commissioning AABC Group ABBREVIATIONS Actual Field Measured Value Pre F Preliminary FPM BAS Building Automation System Prelin Preliminary BHP Brake Horsepower PSI Pounds per Square Inch CFM Cubic Feet per Minute RA Return Air DCFM Design CFM RPM Revolutions Per Minute DDC Direct Digital Control SA Supply Air (CFM) Des Design SF Square Feet Design Based on Plans/Specifications SOH Shut Off Head (feet of water) DP Differential Pressure (feet of water) SP Static Pressure (inches wc) DVel Design Velocity(FPM) TDH Total Dynamic Head (feet of water) EA Exhaust Air(CFM) TSP Total Static Pressure (inches wc) ESP External Static Pressure (inches wc) Vel Velocity(FPM) FLA Full Load Amps we water column (inches) FMD Flow Measuring Device FPM Feet Per Minute Grilles, Registers, and Diffusers GPM Gallons Per Minute CD Ceiling Diffuser HP Horsepower DD Displacement Diffuser "K" "K" Factor EG Exhaust Grill Max Maximum ER Exhaust Register Min Minimum FD Floor Diffuser Nom Nominal LC Light Can NL Not Listed LD Linear Diffuser(Slot) NS Not Specified LT Light Troffer OBD Opposed Blade Damper RD Round Diffuser OA Outside Air(CFM) RG Return Grill OED Open End Duct RR Return Register PD Pressure Drop SG Supply Grille SR Supply Register Prefixes P-*** Preliminary*** Pre-*** Preliminary*** F-*** Final *** Final-*** Final *** ABBREVIATIONS AABC Associated Air Balance council Annual certificate Mark A. Cotroneo, TBE SMB of Minnesota Y� g'� a!F,a O g� a"d & ' MA'- ae, '0/ a.-/ -Oa&wx, �� lwklvnl ffital OwwzwAdawco ,wmk tk,xtak Oa&ane, '.210." �fi rt� t�or� ruurzGe�L 09-04-36r�f l rwco�d &kww a-ad dazm,-,ol . 6' c�, lme oaGe�l on, aw, almmal km&l ,of the ��y 1eca1v1,&- to /&wzz/z;ry • w Michael S.Kelly,President Raymond R.Bert,Executive Director A Digital&Analog FlowmetersI Repair-Testing-Recalibration-Certification mwcal 2584154th Lane NW Phone:(763)205-3576 Andover,MN 55304-2765 sweflocal@gmail.com CERTIFICATE OF CALIBRATION Traceable Number: 121014822-1-1 Customer: SMB of Minnesota Billing PO: 04-23-2021 Cal Date: 5/6/2021 Instrument: Micromanometer Due Date: 5/6/2022 Manufacturer: Shortridge Cal Cycle: 12 Months Model: ADM-870C (Head) Serial: M09739 Asset ID: M09739 Instrument Condition: Received: In Tolerance Ambient Temperature: 70.0° F Returned: In Tolerance Humidity: 38 % Flo-Cal certifies that the above instrument meets or exceeds all published specifications and has been tested using standards and instruments whose accuracies are traceable to the National Institute of Standards and Technology, an accepted value of a natural physical constant or a ratio calibration technique. The policies and procedures at this facility comply with MIL-STD45662A, ISO 17025 and ANSI Z540.3-2007 Calibration Procedure: Shortridge ADM-860(Head) Calibration E ui ment Used: Model/Type Serial Number Due Date Kurz 410 Air Velocity CD1004B 11/30/2021 Precision Digital PD213 1057366 12131/2021 Certified By: DPM Date Printed: May 6, 2021 Quality Assurance: 04U1t4AAV_ Comments: flowcal Digital&Analog Flowmeters I Repair-Testing-Recalibration-Certification 2584154th Lane NW Phone:(763)205-3576 Andover,MN 55304.2765 sweflocal@gmail.com CERTIFICATE OF CALIBRATION Traceable Number: 121014822-1-1 Instrument: Micromanometer Date of Test: 5/6/2021 Manufacture: Shortridge Model: ADM-870C (Head) Test/Job: TST14822-1-155-0-0 Serial: M09739 Calibration Procedure: Shortridge ADM-860 (Head) Asset ID: M09739 Billing PO: 04-23-2021 Range: Various Tolerance: 3% POR plus +/-7 FPM Medium: Air Specific Gravity: 1 Bar. Press: 29.01 In Hg Media Temperature: 70.0° F Received: In Tolerance Returned: In Tolerance Calibration Equipment Used: Model/Type Serial Number Due Date Kurz 410 Air Velocity CD1004B 11/30/2021 Precision Digital PD213 1057366 12/31/2021 Comments: Pitot tube+/-3% of reading plus+/-7 fpm...Diff Press +/-2%of reading. Indicated Actual Pct Indicated Actual Pct Flow As Flow Reading Flow As Flow Reading Tested Received Rate Error Retumed Rate Error Range 6039 6000 0.646 6039 6000 0.646 Pitot Tube 8000 sfpm +/-3 %POR 3062 3020 1.372 3062 3020 1.372 Pitot Tube 8000 sfpm+/-3% POR 1522 1505 1.117 1522 1505 1.117 Pitot Tube 8000 sfpm +/-3% POR 762 754 1.050 762 754 1.050 Pitot Tube 8000 sfpm +/-3% POR 309 315 -1.942 309 315 -1.942 Pitot Tube 8000 sfpm +!-3 % POR 59.40 60.00 -1.010 59.40 60.00 -1.010 Diff Pressure 60"WC +/-2% POR 49.63 50.00 -0.746 49.63 50.00 -0.746 Diff Pressure 60"WC +/-2% POR 29.75 30.00 -0.840 29.75 30.00 -0.840 Diff Pressure 60"WC +/-2% POR 14.86 15.00 -0.942 14.86 15.00 -0.942 Diff Pressure 60"WC+/-2%POR 4.97 5.00 -0.604 4.97 5.00 -0.604 Diff Pressure 60"WC +/-2% POR