Loading...
4009 Haven Woods CtL l 7L/ 931 0, /_7Y77— I �J 1O OL— — — — — — — — — — — — — — — & / -7� ` 79 I For Office Use �• %• �� cif 0l 9 33 j Permit#: 00 EAGANyi 7� Permit Fee: 3830 PILOT KNOB ROAD I EAGAN, MN 55122-1810l.u,tL.QING ECEI VE (651) 675-5675 1 FAX: (651) 675-5694 buildinginspectionsna citvofeaaan com MAR 0 4 a( 0 l -) 64'i 7 GI 2022 2022 RESIDENTIAL P MIT Date: Site Address: 3-3-2022 4009 Haven Woods Cou Resident/ Owner Type of Work Contractor Name: SD Companies LLC Address / City / Zip: c_ Date Received: I I Staff: APPLICATION 651-994-3997 Phone: 750 Main Street Suite 223, Mendota Heights MN 55118 Applicant is: Owner &/ Contractor Owner Email: sean@sd-customhomes.com New Home Description of work: Construction Cost: 600, 000.00 SD Custom Homes Company: 750 Main Street Suite 223 Address: _ MN State: 55118 Zip: Phone: BC 637953 651-994-3997 X Multi-F es / No Contact: Sean Doyle Mendota Heights _City: Email: Sean @sd-customhomes.com License #: Lead Certificate #: If the project is exempt from lead certification, please explain why: New Construction wl/--/ mood, COMPLETE THIS AREA ONLY IF CONSTRUCTING A NEW BUILDING In the last 12 months, has the City of Eagan issued a permit for a similar plan based on a master plan? _Yes ✓ No If yes, date and address of master plan: Licensed Plumber: Scherer Plumbing Mechanical Contractor: Angell Air Voehl Excavation Sewer & Water Contractor: 612-718-4390 Phone: 612-386-6319 Phone: 612-819-8267 Phone: Fire Suppression Contractor: Phone: NOTE: Plans and supporting documents that you submit are considered to be public information. Portions of the information maybe classified as non-public if you provide specific reasons that would permit the City to conclude that they are trade secrets You may subscribe to receive an electronic notification from the City of proposed ordinances by signing up for an email update on the City's website at vvww,citvofeagan.com/subscribe. CALL BEFORE YOU DIG. Contact Gopher State One Call at (651) 454-0002 or www.gopherstateonecall.org for protection against underground utility damage. Contact Gopher State One Call 48 hours before you intend to dig to receive locates of underground utilities. I hereby acknowledge that this information is complete and accurate; that the work will be in conformance with the ordinances and codes of the City of Eagan; that I understand this is not a permit, but only an application for a permit, and work is not to start without a permit; that the work will be in accordance with the approved plan in the case of work which requires a review and approval of plans. Sean Doyle Applicant's Printed Name x Applicant's Signature New Construction Energy Code Compliance Certificate Per R401.3 Certificate. A building certificate shall be posted on or in the electrical distribution Date Certificate Posted panel. Mailing Address of the Dwelling or Dwelling Unit 3/31/2022 Place your City 758 Summerbrooke Court Eagan logo here Name of Residential Contractor Eternity Homes MN License Number 'XVkA-� LLC BC638704 �tRXvt� 151Zo ®+- 1110"l-W THERMAL ENVELOPE RADON CONTROL SYSTEM Type: Check All That Apply X Passive (No Fan) p Active (firth fan and monometer or other W N C system monitoring device) y > Location (or future location) of Fan: _ 6 U a C o y N U — a U 0 o 9 d lo N m J Q m m N N C ) C Insulation Location w z U LL w — _ m 6 3 o` C 0 N 21 N E E a) "O Below Entire Slab Z LL LL ti iY Other Please Describe Here Foundation Wall 10 Perimeter of Slab on Grade 15 X Rim Joist (1st Floor) 21 X X Rim Joist (2nd Floor+) 21 X Wall 20 X Ceiling, flat 49 X Ceiling, vaulted 49 X X Bay Windows or cantilevered areas 30 X Floors over unconditioned area 30 X Describe other insulated areas Building envelope airtightness: Duct system air tightness: Windows & Doors Heating or Cooling Ducts Outside Conditioned Spaces Average LI-Factor (excludes skylights and one door) U: Solar 0.28 X Not applicable, all ducts located in conditioned space Heat Gain Coefficient (SHGC): 0.22 R-value R-8 in garage area MECHANICAL SYSTEMS Make-up Air Select a Type Appliances Heating System Domestic Water Cooling System Heater X Not required per mech. code Fuel Type Gas Gas R-410A Passive Manufacturer Daikin A.O Smith Dalklrl Powered Model DM92SE0603B GPVT-50 DX13SNO30 Interlo Describeed with exhaust device. Rating or Size Input in BTUS: 60,000 Capacity in Gallons: 50 Output 2.5 Other, describe: in Tons: Efficiency AFUE or HSPF% 92% o.�z SEER 13 Location of duct or system: /EER Residential Load Calculation Heating Loss Heating Gain Cooling Load 49,331 15,782 22,652 Cfm's " round duct OR MECHANICAL VENTILATION SYSTEM " metal duct Describe any additional or combined heating or cooling systems if installed: (e.g. two furnaces or air Combustion Air Select a Type source heat pump with gas back-up furnace): Select Type Not required per mech. code X Heat Recover Ventilator (HRV) Capacity in cfms: Low: 82 Nigh: 190 6" Passive Other, describe: Energy Recover Ventilator (ERV) Capacity in cfms: Low: High: Location of duct or system: Balanced Ventilation capacity in cfms: Location of fan(s), describe: Cfm's Capacity continuous ventilation rate in cfms: Total ventilation (intermittent + continuous) rate in cfms:E��� "round duct OR " metal duct Builders Associaton of Minnesota version 101014 ♦ ♦ t / t /E AGA N 3830 PILOT KNOB ROAD 1 EAGAN, MN 55122-1810 (651) 675-5300 1 waterres(&citvofeagan.com 1 /25/2022 Date: Description of Project: r- - - - - - - - - - - - - - - - - - - - - - - - - For Office Use Stormwater Management Permit #: f 7- _T Z b I I I I Building Permit #: � I Q I I I fps, b O I I Escrow Deposit: I I I I Staff: I -------------------------I STORMWATER MANAGEMENT PERMIT 4009 Havenwoods Ct, Eagan Site Address: New Home Build 14,187 sq ft Area of Land Being Disturbed: Start Date: 2/21 /2022 Completion Date: 2/21 /2023 0 Please submit a Land Disturbance and Stormwater Pollution Prevention Plan with this application. SD Csompnaies LLC 651 9943997 Name: Phone: 750 MainSt #223, Mendota Heights, MN 55118 Property Owner Address / City / Zip: Sean sean@sd-customhomes.com Contact: Email: Applicant is: ✓ Owner ✓ Contractor SD Custom Homes BC 637953 Name: License #: 750 Main Street #223 Mendota Heights Contractor Address: City: MN 55118 651 9943997 State: Zip: Phone: Sean Sean 9 sd-custom homes. com Contact: Email: Erosion and Sediment Control Performance Security The City requires an escrow deposit to secure performance of erosion and sediment control (ESC) requirements, including proper installation and maintenance. The security shall pay for any City costs or expenses to bring the site into compliance with the stormwater management permit, including any engineering, legal, or administrative expenses; inspections; and necessary work by City contractor(s). The City may extract from the security escrow. The escrow deposit will be released only upon inspection and written notice of conformance by the City. The following escrow deposits include two (2) required City inspections, initial and final. Existing Single -Family Residential Lot (addition, demolition, pool, retaining wall, etc.) $1,000/lot New Single -Family Construction $3,000/lot Multi -Family or Commercial Construction (new, addition, demolition) $5,000/acre* *Maximum of $12,000 Erosion and Sediment Control Reinspection Fee (for as needed City reinspections after the two (2) included) $85/trip $3, 900 Security Amount: 1-- --q3 2�, The applicant assumes all responsibilities for installation and maintenance of pollution prevention practices on this site Any violations of City Code identified by the City shall be addressed within 48-hours of service of the notification. The applicant understands that failure to maintain pollution prevention practices within the time allotted by the City notification, will result in enforcement action to correct site deficiencies that are in violation of Sec. 4.34. The issuance of this permit constitutes a right -of -entry of the City or its contractors to enter upon the construction site for the purpose of completing ordinance enforcement and/or completing corrective work. hereby acknowledge that this information is complete and accurate; that the work will be in conformance with the ordinances and codes of the City of Eagan; that I understand this is not a permit, but only an application for a permit, and work is not to start without a permit; that the work will be in accordance with the approved plan in the case of work which requires a review and approval of plans. The undersigned accepts full responsibility for compliance with the Stormwater Management Ordinance of the City of Eagan and agrees to comply with the Stormwater Pollution Prevention Plan or equivalent in full. Applicant's Signature Performance Security Release The following information will determine to whom the escrow deposit will be returned. Security will be returned in the form of a check. Name: Address / City / Zip: Phone: Email: Amount: FOR OFFICE USE ONLY Permit Number: SUB TYPE XStormwater Management Permit DESCRIPTION _ Addition _ Demolition X New Retaining Wall WORK TYPE Apartments Multi Family X Single Family Pool Other: Commercial/Industrial Public Facility REQUIRED INSPECTIONS X Initial Inspection XFinal Inspection SECURITY Erosion and Sediment Control Deposit (6501.2257) $3,900 Other: Total: $3,900 Reviewed By: r dan Leyendecker ,Water Resources Date: 01 /26/2022 LOT SURVEY CHECKLIST FOR RESIDENTIAL BUILDING PERMIT APPLICATION PROPERTY LEGAL: Lots 8, Block 1 Havenwoods DATE OF SURVEY: 12/13/21 LATEST REVISION: a� c R s U O z Q DOCUMENT STANDARDS ❑✓ ❑ ❑ • Registered Land Surveyor signature and company ❑ ❑ • Building Permit Applicant ❑✓ ❑ ❑ • Legal description ❑✓ ❑ ❑ • Address ❑✓ ❑ ❑ • North arrow and scale ❑✓ ❑ ❑ • House type (rambler, walkout, split w/o, split entry, lookout, etc.) ❑✓ ❑ ❑ • Directional drainage arrows with slope/gradient % ❑✓ ❑ ❑ • Proposed/existing sewer and water services & invert elevation ❑✓ ❑ ❑ • Street name ❑✓ ❑ ❑ • Driveway (grade & width - in R/W and back of curb, 22' max.) ❑✓ ❑ ❑ • Lot Square Footage ❑✓ ❑ ❑ • Lot Coverage ELEVATIONS Existing ❑ ❑ ❑✓ • Property corners ❑ ❑ ❑✓ • Top of curb at the driveway and property line extensions ❑ ❑ ✓❑ • Elevations of any existing adjacent homes 0 ❑❑ � • Adequate footing depth of structures due to adjacent utility trenches • Waterways (pond, stream, etc.) Proposed ❑✓ ❑ ❑ Garage floor ❑✓ ❑ ❑ • Basement floor ❑✓ ❑ ❑ • Lowest exposed elevation (walkout/window) ❑✓ ❑ ❑ • Property corners ✓❑ ❑ ❑ • Front and rear of home at the foundation No . PRV Required PONDING AREA (if applicable) ❑ ❑✓ ❑ • Easement line ❑ ❑✓ ❑ • NWL ❑ ❑✓ ❑ • HWL ❑ ❑✓ ❑ • Pond # designation ❑ ❑✓ ❑ • Emergency Overflow Elevation ❑ ❑� ❑ • Pond/Wetland buffer delineation No . Shoreland Zoning Overlay District FNo---1 . Conservation Easements DIMENSIONS ❑✓ ❑ ❑ • Lot lines/Bearings & dimensions ❑✓ ❑ ❑ • Right-of-way and street width (to back of curb) ❑ ❑ ❑✓ • Proposed home dimensions including any proposed decks, overhangs greater than 2', porches, etc. (i.e. all structures requiring permanent footings) ❑✓ ❑ ❑ • Show all easements of record and any City utilities within those easements ❑ ❑ ✓❑ • Setbacks of proposed structure and sideyard setback of adjacent existing structures ❑� ❑ ❑ • Retaining wall requirements: Reviewed By: Dave Westermayer Date 3/11/22 GA Engineering/Forms/Cert. of Survey Checklist Fillable 03-16-2021 ADDRESS: LEGAL DESCRIPTION: 4009 HAVEN WOODS CT. LOT 8, BLOCK 1, HAVEN WOODS EAGAN, MN 55123 DAKOTA COUNTY,MINNESOTA SD CUSTOM HOMES PLAN: PLAN: THE ROCK CREEK -9 FT. FULL BASEMENT - PLAN DATE: 11/30/21 1 n—r ADGA- LOT AREA = 14,187 SQ. FT. OR 0.325 ACRES IMPERVIOUS AREA = 4,282 SQ. FT (30.1%) BUILDING FOOTPRINT AREA = 2,779 SQ. FT. DRIVEWAY TO PROPERTY LINE = 1,711 SQ. FT Building Coverage = 19.6% 902. BENCH MARK: TOP NUT OF FIRE HYDRANT AT THE CORNER OF LOTS 5 AND 6, BLOCK 1, HAVEN WOODS ELEVATION = 903.12 (NGVD29) CERTIFICATE OF SURVEY FOR: SD CUSTOM HOMES PROPOSED ELEVATIONS: TOP OF FOUNDATION = 903.7 GARAGE FLOOR = 903.2 BASEMENT FLOOR = 895.0 REAR = 903.0 NOTES: 3:1 MAX. SLOPES OR RETAINING WALL REQUIRED INSTALL PERIMETER CONTROL____ � 1. SURVEY PREPARED FROM ALLIANT ENGINEERING, INC. GRADING PLAN DATED OCTOBER 22, 2019. 2. BEARINGS ARE ASSUMED PER PLAT 3. BUILDING DIMENSIONS SHOWN ARE TO OUTSIDE FRAMING OF FIRST FLOOR PLAN. ALL DIMENSIONS AND LOCATIONS ARE TO BE VERIFIED IN THE FIELD WITH THE ARCHITECTURAL PLANS. LANDSCAPE LEGEND: 11�cPROPOSED DECIDUOUS OVERSTORY TREE 0�PROPOSED CONIFEROUS TREE PROPOSED ORNAMENTAL TREE Y� TC 891 / SO 9,09 899. 23/ 110 TC 0 10 20 40 SCALE IN FEET LEGEND: X 934.0 EXISTING ELEVATION 934.0 PROPOSED ELEVATION DIRECTION OF DRAINAGE O @cs EOF LFE T CCI u (P) 900 — IRON MONUMENT SET CURB STOP EMERGENCY OVERFLOW LOWEST POSSIBLE FLOOR TOP OF CURB TELEPHONE BOX ELECTRIC BOX ELEVATION PER PLAN PROPOSED CONTOURS — BUILDING PAD r—� I I WETLAND BUFFER MONUMENT /L�_'JJ ( a j �1--0--o- EXISTING TREES SILT FENCE REVIEWED FOR CODE COMPLIANCE EAGAN Dave Westermayer 03/18/2022 2:34:58 PM ENGINEERING REVISED: 3117122 SWAP SIDE SETBACKS DISTANCES PER CITY REQUEST. From:Kathy Doyle To:Building Inspections Cc:Vark Tadian; Samantha Lykke Subject:4009 Haven Woods Court Date:Friday, September 9, 2022 11:34:03 AM Attachments:image001.png image002.png image003.png image004.png image005.png Hello, We are changing the Mechanical Contractor from Angell Aire Inc, Burnsville MN to Air Mechanical Inc, 16411 Aberdeen St NE, Ham Lake, MN 55304 phone number 763-434-7747. I have cc’d Samantha Lykke from Air Mechanical on this email in case you have any questions for Air Mechanical Inc. Air Mechanicals – Mech Bond number is MB005122. The permit number for this project at 4009 Haven Woods Court is EA174976. The Mechanical Permit Number is EA174978. Please let me know if you have any questions. Thank you, Kathy Kathy Doyle 651.994.3997 KATHY@SD-CUSTOMHOMES.COM PERMIT City of Eagan Permit Type:Building Permit Number:EA179175 Date Issued:09/21/2022 Permit Category:ePermit Site Address: 4009 Haven Woods Ct Lot:8 Block: 1 Addition: Haven Woods PID:10-32090-01-080 Use: Description: Sub Type:Fireplace Work Type:Gas Fireplace (new) Description: Census Code:434 - Residential Additions, Alterations Zoning: Square Feet:0 Occupancy: Construction Type: Comments:Improvements to the home may require smoke detectors in all bedrooms. Chimney / flue must be inspected prior to concealing. Carbon monoxide detectors are required within 10 feet of all sleeping room openings in residential homes (Minnesota State Valuation: 3,000.00 Fee Summary:BL - Base Fee $3K $88.50 0801.4085 Surcharge - Based on Valuation $3K $1.50 9001.2195 $90.00 Total: This permit shall be null and void if work does not start within 180 days of issuance, or if work is suspended for 180 days or more after started. I hereby acknowledge that I have read this application and state that the information is correct and agree to comply with all applicable State of Minnesota Statutes and City of Eagan Ordinances. Contractor:Owner:- Applicant - Sd Companies Llc 4009 Haven Woods Ct Eagan MN 55123 Glowing Hearth And Home Llc 100 Eldorado Dr. Jordan MN 55352 (952) 492-9276 Applicant/Permitee: Signature Issued By: Signature