10079 Eagan MN-COMcheck �( COMcheck Software Version 4.1.5.1
Interior Lighting Compliance Certificate
Project Information
Energy Code: 90.1 (2016) Standard
Project Title: Kohls 10079 Eagan MN
Project Type: Alteration
Construction Site: Owner/Agent: Designer/Contractor:
1350 Town Center Drive Kohls Department Stores Eugenia Koverman
Eagan, MN 55123 N56 W17000 Ridgewood Drive Casco
Menomonee Falls, WI 53051 12 Sunnen Dr. Suite 100
(262) 703-7000 St. Louis, MO 63143
(314) 821-1100
Allowed Interior Lighting Power
A B C D
Area Category Floor Area Allowed Allowed Watts
(ft2) Watts/ft2 (B X C)
1-Retail:Sales Area 81975 1.22 100010
Total Allowed Watts= 100010
Proposed Interior Lighting Power
A B C D E
Fixture ID : Description/Lamp/Wattage Per Lamp/Ballast Lamps/ #of Fixture (C X D)
Fixture Fixtures Watt.
Retail:Sales Area(81975 sq.ft.)
LED:A:existing LED 2 x 4:Other: 1 713 34 24242
LED:B:existing LED 2 x 2:Other: 1 113 17 1921
LED:L2X:Existing 2'cornice light:Other: 2 5 24 120
LED:L3X:Existing 3'cornice light:Other: 2 21 34 714
LED:L4X:Existing 4'cornice light:Other: 2 13 42 546
LED:C3X:Existing T cornice light:Other: 2 113 34 3842
LED:C4X:Existing 4'cornice light:Other: 2 233 42 9786
LED:LD3:Existing 3'cornice light:Other: 2 10 34 340
LED:LD4, LR4:Existing 4'cornice light:Other: 2 35 42 1470
LED:Q4:Existing 4'recessed light:Other: 2 10 42 420
LED:TS2:Existing 2'recessed light:Other: 1 2 12 24
LED:TS3:Existing 3'recessed light:Other: 1 7 17 119
LED:TS4:Existing 4'recessed light:Other: 1 23 21 483
LED:WRL,WRTL:existing LED wall washer:Other: 1 239 24 5736
LED:T,W:Existing down light:Other: 1 25 24 600
LED:JR1:Existing pendant light:Other: 4 1 96 96
Track lighting:NFL:track lighting: Wattage based on 288 feet of track 0 0 8640 8640
LED:R-A:Relocated LED 2 x 4:Other: 1 1 34 34
LED:1-3:New 3'cornice light:Other: 1 1 34 34
LED:1-4:New 4'cornice light:Other: 1 13 42 546
LED:XAL4:New 4'Linier light:Other: 1 2 44 88
LED:XLA5:New 5'tinier LED:Other: 1 7 55 385
Project Title: Kohls 10079 Eagan MN Report date: 02/08/22
Data filename: L:\Kohls\Projects\2022 Sephora\Eagan MN 10079-2101304\CDs\Calcs\10079 Eagan MN Page 1 of 6
2101304.cck
A B C D E
Fixture ID : Description/Lamp/Wattage Per Lamp/Ballast Lamps/ #of Fixture (C X D)
Fixture Fixtures Watt.
LED:XAL8:New 8'Linier light:Other: 1 36 88 3168
Total Proposed Watts= 63354
Interior •
Interior Lighting Compliance Statement
Compliance Statement: The proposed interior lighting alteration project represented in this document is consistent with the
building plans, specifications, and other calculations submitted with this permit application.The proposed interior lighting
systems have been designed to meet the 90.1 (2016) Standard requirements in COMcheck Version 4.1.5.1 and to comply with
any applicable mandatory requirements listed in the Inspection Checklist.
Name-Title 'ig'naffjre Date
t torero Cori" that this plan,
f t"s proparnd by me Of under my dired
Islon and that I am a duly �_icensed
=sional Engineer under the laws of 4he
SWe o9 Minnesota A
Harry J. dman
�{grratur®:
1Xd46 �iodnsd a 48114
Project Title: Kohls 10079 Eagan MN Report date: 02/08/22
Data filename: L:\Kohls\Projects\2022 Sephora\Eagan MN 10079-2101304\CDs\Calcs\10079 Eagan MN Page 2 of 6
2101304.cck
COMcheck Software Version 4.1.5.1
Inspection Checklist
Energy Code: 90.1 (2016) Standard
Requirements: 0.0% were addressed directly in the COMcheck software
Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each
requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception
is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided.
Section
# Plan Review Complies? Comments/Assumptions
& Req.ID
4.2.2, Plans, specifications, and/or ❑Complies
8.4.1.1, calculations provide all information ❑Does Not
8.4.1.2, with which compliance can be
8.7 determined for the electrical systems ❑Not Observable
[PR6]2 and equipment and document where ❑Not Applicable
exceptions are claimed. Feeder
connectors sized in accordance with
approved plans and branch circuits
sized for maximum drop of 3%.
4.2.2, Plans, specifications, and/or ❑Complies
9.4.3, 9.7 calculations provide all information ❑Does Not
[PR4]1 with which compliance can be
determined for the interior lighting ❑Not Observable
and electrical systems and equipment ❑Not Applicable
and document where exceptions to
the standard are claimed. Information
provided should include interior
lighting power calculations, wattage of
bulbs and ballasts,transformers and
control devices.
Additional Comments/Assumptions:
111 High Impact(Tier 1) 2 1 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: Kohls 10079 Eagan MN Report date: 02/08/22
Data filename: L:\Kohls\Projects\2022 Sephora\Eagan MN 10079-2101304\CDs\Calcs\10079 Eagan MN Page 3 of 6
2101304.cck
Section
# Rough-In Electrical Inspection Complies? Comments/Assumptions
& Req.ID
8.4.2 ;At least 50%of all 125 volt 15-and ❑Complies
[EL10]2 120-Amp receptacles are controlled by ❑Does Not
an automatic control device.
❑Not Observable
�E]Not Applicable
8.4.3 :New buildings have electrical energy ❑Complies
[EL11]2 use measurement devices installed. ❑Does Not
Where tenant spaces exist, each
;tenant is monitored separately. In ❑Not Observable
buildings with a digital control system ❑Not Applicable
;the energy use is transmitted to to
control system and displayed
graphically.
9.4.1.1 ;Automatic control requirements ❑Complies
[EL1]2 :prescribed in Table 9.6.1,for the ❑Does Not
;appropriate space type, are installed.
Mandatory lighting controls (labeled ❑Not Observable
as 'REQ') and optional choice controls ❑Not Applicable
(labeled as 'ADD1' and 'ADD2') are
implemented.
9.4.1.1 Independent lighting controls installed ❑Complies
[EL2]2 per approved lighting plans and all ❑Does Not
manual controls readily accessible and
:visible to occupants. ❑Not Observable;
❑Not Applicable
9.4.1.1f :Daylight areas under skylights and Elco mplies
[EL13]1 roof monitors that have more than ❑Does Not
;150 W combined input power for
,general lighting are controlled by ❑Not Observable;
photocontrols. ❑Not Applicable
9.4.1.3 ;Separate lighting control devices for ❑Complies
[EL4]1 specific uses installed per approved ❑Does Not
:lighting plans.
❑Not Observable
❑Not Applicable
9.6.2 ;Additional interior lighting power ❑Complies
[EL8]1 allowed for special functions per the ❑Does Not
:approved lighting plans and is
;automatically controlled and ❑Not Observable;
separated from general lighting. ❑Not Applicable
Additional Comments/Assumptions:
111 High Impact(Tier 1) 2 1 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: Kohls 10079 Eagan MN Report date: 02/08/22
Data filename: L:\Kohls\Projects\2022 Sephora\Eagan MN 10079 -2101304\CDs\Calcs\10079 Eagan MN Page 4 of 6
2101304.cck
Section
# Final Inspection Complies? Comments/Assumptions
& Req.ID
8.7.1 I Furnished as-built drawings for ❑Complies
[F116]3 electric power systems within 30 days ❑Does Not
of system acceptance.
❑Not Observable
�E]Not Applicable
8.7.2 :Furnished O&M instructions for ❑Complies
[F117]3 systems and equipment to the ❑Does Not
:building owner or designated
representative. ❑Not Observable
❑Not Applicable
9.2.2.3 Interior installed lamp and fixture ❑Complies ;See the Interior Lighting fixture schedule for values.
[F118]1 lighting power is consistent with what ❑Does Not
:is shown on the approved lighting
:plans, demonstrating proposed watts ❑Not Observable
,are less than or equal to allowed ❑Not Applicable
watts.
9.4.4 ;At least 75%of all permanently ❑Complies
[F120]1 installed lighting fixtures in dwelling ❑Does Not
units have >= 55 Im/W efficacy or a
>= 45 Im/W total luminaire efficacy. ❑Not Observable
❑Not Applicable
Additional Comments/Assumptions:
111 High Impact(Tier 1) 2 1 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: Kohls 10079 Eagan MN Report date: 02/08/22
Data filename: L:\Kohls\Projects\2022 Sephora\Eagan MN 10079 -2101304\CDs\Calcs\10079 Eagan MN Page 5 of 6
2101304.cck
Project Title: Kohls 10079 Eagan MN Report date: 02/08/22
Data filename: L:\Kohls\Projects\2022 Sephora\Eagan MN 10079 - 2101304\CDs\Calcs\10079 Eagan MN Page 6 of 6
2101304.cck