Loading...
1393 Cleome LaneFOR OFFICE USE ONLY Site Address: 11>9 3 CIe—Gw L Permit #: l '-1 i nWI SUB TYPES Foundation _ Fireplace _ Porch (3-Season) Miscellaneous Single Family _ Garage _ Porch (4-Season) _ Accessory Building _ Multi Deck _ Porch (Screen/Gazebo/Pergola) 01 of Plex Lower Level Pool WORK TYPES New _ Repair _ Siding _ Retaining Wall - Addition _ Fire Repair _ Reroof Move Building — Alteration Water Damage _ Windows _ Demolish Building* Replace Egress Window _ Solar "Demolition of entire building -give PCA handout to — applicant DESCRIPTION Calculated Valuation 1170,-LM . 9 Occupancy jRG-1. MCES System Plan Review Code Edition 114NQC.-Zj:Lc, SAC Units (25%_ 100Q� Zoning City Water Census Code Stories Booster Pump # of Units Square Feet PRV # of Buildings Length Fire Suppression Required Type of Construction - ,IN3 Width REQUIRED INSPECTIONS Footings (New Building) Footings (Deck) Footings (Addition) Foundation ✓ioFoundation Before Backfill V Roof: / Ice & Water ✓Final) Framing 30 Minutes ✓ 1 Hour Fireplace: _Rough In _Air Test _Final Insulation V Sheathing Sheetrock Fire Walls Braced Walls Shower Pan Meter Size: v Final / C.O. Required Final / No C.O. Required HVAC _ Service Test Gas Line Air Test _ Hood Pool: _Footings Air/Gas Tests _Final Drain Tile Siding: _Stucco Lath _Stone Lath _Brick _ EFIS Windows Retaining Wall: _ Footings — Backfill _ Final Radon Control Fire Suppression: _Rough In _Final Erosion Control Other: Reviewed By:� Z1 z , Building Inspector RESIDENTIAL FIE ES►b •`'`' - i5=' Calculated Valuation g65 A 495.73 -1.7,o+vL-" Base Fee .� � t" X 45.73 IWOqu Plan Review `r.�ei _ t�a�j 3l yt7.r i1ti15y,° State Surcharge q� !F. �'ch x + MCES SAC -�---� City SAC Utility Connection Charge S&W Permit & Surcharge Treatment Plant Radio Read Other: Copies: TOTAL $ 0.00 1 — For Office Use ®.._._._._._._ — — — -.._.— -w — .,..I //��'��yl 0'0 j Stormwater Management Permit #: � k0l- I EAGAN j Building Permit #: 17--�5 3-q2 I I Escrow Deposit: 3830 PILOT KNOB ROAD I EAGAN, MN 55122-1810 I I I l (651) 675-5300 1 waterres@cityofeaaan.com I Staff: I ------------------------- STORMWATER MANAGEMENT PERMIT Date: 3/30/2022 Parcel B Cleome Wilderness Run Lot 22 Block 2 — — _ Site Address: / Description of Project:New Home Construction�� � �C'� ✓1/1 /' L �,�}� Area of Land BeingDisturbed: Lot 4/15/2022 Date: : 7/30/`20J22C" _ _ Start Date: Completion Date: _ Please submit a Land Disturbance and Stormwater Pollution Prevention Plan with this application. Name: TTCP 6513368767 Phone: Property Owner Address /City /Zip: 9531 W 78th Street #135 Eden Prairie, MN 55344 Contact: Melvin Moore Email: mlmoore00@yahoo.com Applicant is: Owner -✓ Contractor Stri ht Line Construction LLC QB771891 Name: g License #: N 2nd Street Unit 208 Address:129._ City: Minneapolis Contractor M N 55401 6126694227 State: — Zip: _.,_..� Phone: Contact: Brian Haas Email: brian@hrhhcompanies.com Erosion and Sediment Control Performance Security The City requires an escrow deposit to secure performance of erosion and sediment control (ESC) requirements, including proper installation and maintenance. The security shall pay for any City costs or expenses to bring the site into compliance with the stormwater management permit, including any engineering, legal, or administrative expenses; inspections; and necessary work by City contractor(s). The City may extract from the security escrow. The escrow deposit will be released only upon inspection and written notice of conformance by the City. The following escrow deposits include two (2) required City inspections, initial and final. Existing Single -Family Residential Lot (addition, demolition, pool, retaining wall, etc.) $1,300/lot New Single -Family Construction $3,900/lot Multi -Family or Commercial Construction (new, addition, demolition) *M$6,500/acre* *Maximum of $12,000 Erosion and Sediment Control Reinspection Fee (for as needed City reinspections after the two (2) included) $85/tri Security Amount: $3900-000 The applicant assumes all responsibilities for installation and maintenance of pollution prevention practices on this site. Any violations of City Code identified by the City shall be addressed within 48-hours of service of the notification. The applicant understands that failure to maintain pollution prevention practices within the time allotted by the City notification, will result in enforcement action to correct site deficiencies that are in violation of Sec. 4.34. The issuance of this permit constitutes a right -of -entry of the City or its contractors to enter upon the construction site for the purpose of completing ordinance enforcement and/or completing corrective work. I hereby acknowledge that this information is complete and accurate; that the work will be in conformance with the ordinances and codes of the City of Eagan; that I understand this is not a permit, but only an application for a permit, and work is not to start without a permit; that the work will be in accordance with the approved plan in the case of work which requires a review and approval of plans. The undersigned accepts full responsibility for compliance with the Stormwater Management Ordinance of the City of Eagan and agrees to comply with the Stormwater Pollution Prevention Plan or valent in full. Brian Haas x x Applicant's Printed Name plicant's Si ature Performance Security Release The following information will determine to whom the escrow deposit will be returned. Security will be returned in the form of a check. Name: Brian Haas Address (City /Zip: 494 La Grandeur Somerset, WI 54025 Phone: 6126694227 Email: Brian@hrhhcompanies.com Amount FOR OFFICE USE ONLY SUB TYPE X_ Stormwater Management Permit Permit Number: WORK TYPE Apartments Multi Family X Single Family DESCRIPTION _ Addition Demolition Pool X New Retaining Wall Other: REQUIRED INSPECTIONS X Initial Inspection XFinal Inspection SECURITY Erosion and Sediment Control Deposit (6501.2257) $3,900 Other: Total: Z�,3,yUU Commercial/Industrial Public Facility 4/7/2022 Reviewed By: "` "rW Brian Leyendecker Water Resources Date: n V m o 0M Z m i u o 0 2 o D n m y w m G) Tm 0D ZE m �m z3D �� Orr- v . Gl QQ z y 0 3 Z i0 z �N g m �f �, m v� -i m � r g 0 i m MILPT KNOB ROAD (CO. RD. 31) X � r� -mi 00 V 4 V InP;f"M;r,5iIE �VV� T m �' OHE-A OHE--vn£=U-OHE 0HE 0HE- -:. _ (N 00'09'40" W PLAT) N 0019'40" W ° miry a (115.00 plat) n z o;c E � A — — — 114.53- 0:0 En roK �m a mo 0� ooz Am i' rmp� 3 m, moo o z y 10 I �o N I 16 �.j mo a a z m LA , m m �^ N m ( d c vai ° °zs 00 Nw� I } <n my tv I o�664 '.Nia ~ ig o ° z� ma nmm m No ��N � i'" mm i � = v~i z A z > o a a E.� '�� I z �' ' - '15_00 ti� .,? 10.43 ------ A �� 0, o�rr- F a .7. _rri 43.92 -- f - - - - - ~ c o o A o A z r• :. �12.91 PROPOSED N, z m x o ® 3 5 c '9 .0 HOUSE I m N F ZO Nm 0m 1y � O� = a ■i>� 'obi ' m +•mow �- mm , �-�- 5.0 Ma �V? -- Qi ---- 21.0_ o y a z me o o Paso a 4.86 10.6 - 900.7 $ os � oz �'� j Oai .0� 60£''•'y c ♦� .y FF o o C i ti 6 x A T tail z � n� ° cn A � .�i � 90pr) ^' L 4�� �`` -•. v `i z m x Aa m ii w m o °pm � m 00 0 oo wao- m yi mm om �z o (� ; m �a i 5560 i �m r x o csi m �i m y m o f 1 / (55 53 plat) a c m y A'c m< No S 004738 E oho 'mn m o A 0 m a (S 00'26'10" E PLAT) o o m o m A ro m• N �_- m z� m nz o f1a 5zo mz5 m z ° zm w „ ,,,z SiAp n iD m 3+ n a oa oa'v o m o D mm <vm> Iv Ora o �' m va o���� z a z m° � mom 9 \ r1l O Z zi ;Am m yi ci az c z rn z Z�r W " Z N _• -A.� T a7 CD x z Z N V-V+OAOI \ (p W m-n c r O F> T .. N 0 Vi Z M I1 I1 Z V m O � co m r OD 14 N m N m m .. o ;u I- ..j '>»� z ® ® o • a pZO rrr Z +* 3A o 01r. - s. 0 m m m H D�� `1 o 3z Fh 4 m �'a0o n o 0 0 0 y O M r.r zc m a ^` �0 N m C O 7 C m O VJ Vl 41 VI w N '` mWml5 o�W°mo \ 5 m A A Z o l w D N m�i u m v � 5 - ' "02r Z w z N n 3 n�'i , m (n r o .� m o q�a° 0 V ; Z O �� ] Z n n Oil N A 5 O o %g IJ N r r Q- z a m o o �o O ° No rtm3 3 o C7 �c oy�o 3 coo. -� N N O N o m Z TREE PRESERVATION PLAN REVIEW —INDIVIDUAL LOT ! r t / / EAGAN Date Building Permit Application Received 3/31/22 Development Wilderness Run Second Addition Lot 22 Block 2 Site Address-1 393 Cleome Ln Builder Straight Line Construction LLC Contact Brian Haas Telephone 612-669-4227 E-mail Brianp_hrhhcompanies.com Property/Lot Owner Name TTCP Telephone 651-336-8767 E-mail mlmoore00(a yahoo.com Office Plan Review — Date 4/4/22 Notes No Tree Pres Plan filled with Building ap Information sent 4/4/22. Tree Inventory Received 4/13/22. Initial tree inventory review includes tree removal over allowable limit. Required Mitigation calculates to 5 Trees. Trees can be split between lots 1389 & 1393 Cleome Ln. Update 4/25/22 Mitigation will be provided throuah cash dedication. Tree Preservation Data Total Significant Woodland Area Total Significant Trees Woodland To Be Removed Trees To Be Removed Allowable Woodland Removal (20%) Allowable Tree Removal (20%) Required Mitigation YES (or) NO Original Plan - 2.5 Revised Plan - Original Plan sq. ft 94 sq.ft 24 sq.ft 19 Revised Plan Calculated Mitigation Amounts Category A 5 Category B Category C Category A Category B Category C q. ft ft ft Site Inspection— Date 4/15/22 Notes Tree removals complete. Home locations staked Several small trees marked with green ribbon have Critical Root Zone conflicts with Home stakes. (CRZ encroachments resolved by On -site meeting 4/22/22) G:\Forestry\TreePreservation\Tree Preservation Plan Review - Individual Lot.docx Original Tree Preservation Plan Approved — Date 4/22/22 By AS Forwarded to Inspections — Date 4/25/22 By AS Discussion/Meetings with Builder/Owner - Notes Revised Tree Preservation Plan Approved — Date By Forwarded to Inspections — Date By Additional Field Inspections Date Notes Date Notes Date Notes Date Notes G:\Forestry\TreePreservation\Tree Preservation Plan Review - Individual Lot.docx Was the approved Tree Preservation Plan followed? If no, was additional mitigation required? YES (or) Final Site Inspection — D Additional Notes and/or aerial photo image YES (or) NO NO (If yes, describe additional mitigation below) (insert aerial image or draw map of site) :\Forestry\Tree Pre servatinn\Tr.. c—e.,,--- -- o_..:_.. .. . a \ > < E 2 0 5 k a \ § \ / \ k \< 0 0 0 0\ 0 0 n 0 f = 7 j Q 0 0 0 0 z 0 0 z I § # / } \ / \ \ - - - - \ / f \ (D _ IT # # CN a a _) i § / / 0 0 0 0 4 0 0 \ E 0 \ ƒ m (3) E 2 2 e z e z \ f \ 2;%§ # - § \ 9 \ � R = _0e / § co2 } > ) ^ \ § ) / o ( c \ - \ \ -O\ E 0 / 0 ¥ 0 § ®° s = 0 / = 2 / CO \ U \ \ 0 \ \ 0 § @ �w 3 .± .0 D 12 U io 0 ± O > „ O 0 U) "= b \ / ±gc w 2 E 2 2 = � \ / \ -0 LL \ E Q ¥ �f'k z \ cr �\k Oc0 Tree Preservation Plan Required Tree Protection For 1389 & 1393 Cleome Ln 3 i 2 � o C'F T yr ���t•ri�Y�rrr� ti lip ^• 4 v /! • � i EAGAN FORESTRY DIVISION REVIEWED BY: A. SCHNAIBLE DATE: 4/22/22 EAGAN ?" City Inspection Dept. Copy City Forester Copy Applicant/Builder Copy INDIVIDUAL RESIDENTIAL LOT TREE PRESERVATION PLAN SUMMARY CITY OF EAGAN FORESTRY DIVISION 651-675-5300 (BUILDER, PLEASE READ ATTACHMENTS) Development WILDERNESS RUN 2ND ADDITION Lot Number 22 Block Number 2 Address 1393 Cleome Ln Builder Straight Line Construction LLC I HRHH Companies Phone Number: 612-499-1758 Contact: Troy O'Connell — Project Manager Tree Protection Requirements: X Tree Protection Fencing (Orange Poly Fence) to be installed and on -site until construction completion Oak Tree Pruning (immediately seal wounds during April 1 to July 31) Therapeutic Pruning Required Retaining Wall To Be Installed Other: Replacement Trees: X Not Required: subject to mitigation if allowable limits are exceeded As Follows: Five (0) Category B trees (>= 2.5" caliper deciduous trees, or >= 6' conifer trees) to be installed. Attachments: X Yes (Refer to attache I 9Au Q Ws6FaQ1RESTRY DIVISION No REVIEWED Additional Notes: BY ApL� _6_a_j&asLg ( I 25—/Zo2v TREE PRESERVATION PLAN - 1393 Cleome Ln.docx New Construction Energy Code Compliance Certificate Per R401.3 Certificate. A building certificate shall be posted on or in the electrical distribution Date Certificate panel. Mailing Address of the Dwelling or Dwelling Unit City 1393 Clleome St Eagen Name of Residential Contractor MN License Number Highpointe Homes BC794997 THERMAL ENVELOPE RADON CONTROL SYSTEM Type: Check All That Apply X Passive (No Fan) a) or other system monitoring o Location (or future location) of Fan: F �0 y a m a) as U Q C 3 ° .N. m — U _ O d - a) m 7 n Q m D] ate) U s a) -00 c Insulation Location > ° O Z N as m T N O v Q O -0 L w T Ln m @� o c 21 aV � a) E m E m m o -a — p F° z° u- � i° J_ 2 of w Other Please Describe Here Below Entire Slab X Foundation Wall R-15 I I Ix Perimeter of Slab on Grade R-10 I I Ix Rim Joist (1st Floor) R-21 X Rim Joist (2nd Floor+) R-21 X Wall R-21 X Ceiling, flat R-49 X vcnu 1y, vawLcu R-47 I I Ix Bay Windows or cantilevered areas R-30 I Ix Floors over unconditioned area Describe other insulated areas R-30 I I I ix Building envelope air tightness: Duct system airtightness: Windows & Doors Heating or Cooling Ducts Outside Conditioned Spaces Average U-Factor (excludes skylights and one door) U: 0.18 X INot applicable, all ducts located in conditioned space Solar Heat Gain Coefficient (SHGC): 10.24 R-value MECHANICAL SYSTEMS Make-up Air Select a Type Appliances Heating System Domestic Water Heater Cooling System X Not required per mech. code Fuel Type Gas Electric Electric Passive Manufacturer Bryant Rheem Bryant I Powered Model Legacy1915 Bradford White 13 Seer 1128 Interlocked with exhaust device. Describe: Rating or Size Input in BTUS: 40000 Capacity in Gallons: 50 Output in Tons: 1.5 Other, describe: Efficiency AFUE or HSPF% 95.5 �os7 SEER /EER 13 SEED Location of duct or system: Basement Trusses Cfm's Residential Load Calculati i Heating Loss 35964 Heating Gain 11695 Cooling Load 14793 6" " round duct OR MECHANICAL VENTILATION SYSTEM I .metal duct Describe any additional or combined heating or cooling systems if installed: (e.g. two furnaces or air source heat pump with gas back-up furnace): Select Type Combustion Air Select a Type Not required per mech. code X Passive Heat Recover Ventilator (HRV) Capacity in cfms: Low: High: I Other, describe: Energy Recover Ventilator (ERV) Capacity in cfms: Low: 160 High: 1110 Location of duct or system: Balanced Ventilation capacity in cfms: Location of fan(s), describe: lBathrooms I jCfm's Capacity continuous ventilation rate in cfms: 180 Cfm X "round duct OR Total ventilation (intermittent + continuous) rate in cfms: 1110 "metal duct Builders Associaton of Minnesota version 101014 Rhvac Residential &light Commercial HVAC loads - �Itte Software IDe�elopJltent; Inc Au_er5teel`{Plymouth) Central Healing & Coollnq RVM666.,MW55441e 6 Total Building Summaty Loads Component - v - c Area Sen: _- Lai Sen _ Total:' Descri"tion' ... _- uan :Loss- Gain Gain = . _Cain; Marvin: Glazing -Custom Window, U-value 0,32, SHGC 173.5 4,829 0 3,719 3,719 0.34 11P: Door -Metal - Polyurethane Core, U-value 0.29 45 1,136 0 313 313 15BO-10sf-4: Wall -Basement,, R-10 board insulation to 466 2,190 0 0 0 floor, no interior finish, 4' floor depth, U-value 0.054 12F-Osw: Wall -Frame, R-21 insulation in 2 x 6 stud 1925.5 10,889 0 1,663 1,663 cavity, no board insulation, siding finish, wood studs, U-value 0.065 168-50: Roof/Ceiling-Under Attic with Insulation on Attic 1040 1,810 0 998 998 Floor (also use for Knee Walls and Partition Ceilings), Vented Attic, No Radiant Barrier, Dark Asphalt Shingles or Dark Metal, Tar and Gravel or Membrane, R-50 insulation, U-value 0.02 21B-20: Floor -Basement, Concrete slab, any thickness, 2 880 1,455 0 0 0 or more feet below grade, R-3 or higher insulation installed below floor, any floor cover, shortest side of floor slab is 20' wide, U-value 0.019 22D-10pm: Floor -Slab on grade, Vertical board insulation 32 955 0 0 0 covers slab edge, turns under slab and extends 4' horizontally, any floor cover, R-10 insulation, passive, heavy dry or light wet soil, U-value 0.343 20P-30: Floor -Over open crawl space or garage, Passive, 160 487 0 45 45 R-30 blanket insulation, any cover, U-value 0.035 Subtotals for structure: 23,751 0 6,738 6,738 People: 4 800 920 1,720 Equipment: 0 2,400 2,400 Lighting: 0 0 0 Ductwork: 0 0 0 0 Infiltration: Winter CFM: 92, Summer CFM: 48 8,499 747 669 1,416 Ventilation: Winter CFM: 100, Summer CFM: 100 3,714 1,551 555 2,106 Exhaust: Winter CFM: 100, Summer CFM: 100 AED Excursion: _ 00 413 413_ Total Building Load Totals: 35,964 3,098 11,695 14,793 - Total Building Supply CFM: 522 CFM Per Square ft.: 0.272 Square ft. of Room Area: 1,920 Square ft. Per Ton: 1,557 Volume (W): 14,452 Buildiri ;Loads s Total Heating Required Including Ventilation Air: �rk'4A;964' Btuh 35,964 MBH Total Sensible Gain: 11,695 Btuh 79 % Total Latent Gain: 3,098 Btuh 21 % Total Cooling Required including Ventilation Air: + 1$j93 Btuh 4�,23 Tons Based On Sensible + Latent) - Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. na.,,..,t, ea Ono) n•an onn S stem l Room Load Summaiy IV t ---.wntj I--- 1 Foundation 880 14,378 192 2-6 495 4,152 692 195 195 2 Main Floor 1,040 17,872 239 3-7 408 6,988 855 327 327 — Ventilation 3,714 _ 555 1,551 ^ System 1 total 1.920 35.964 432 11,695 3.098 522 522 System 1 Main Trunk Size: 9x12 in. Velocity: 696 ft./min Loss per 100 ft.: 0.103 ln.wg Coolin 3 s em Siam a : 4 ram- r.; -z .s-;s - r 4 f kim � � Net Required: 1.23 79% / 21 % 11,695 3,098 14,793 E u me t Dafa:_. Type: Heating System Natural Gas Furnace Cooling SySBt mm Standard Air Conditioner Model: Indoor Model: Brand: Efficiency: 0 AFUE 0 SEER Sound: 0 0 Capacity: 0 Btuh 0 Btuh Sensible Capacity: n/a 0 Btuh Latent Capacity: n/a 0 Btuh KA___L An- I)nnn A.40 t-)hA E!(te Software Development, lric ;: Auer Steel (Plymoufh) C�ntral;Heafinq & Coolfr�,q Rhvac `Residential &Light Cotpmerclal HVAC LoadsPI Y-ii-aou N 55 ., .... , , a e:8. Detailed Room Loads - Room 1- Foundation Average Load Procedure Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 27.5 ft. System Number: 1 Room Width: 32.0 ft. Zone Number: 1 Area: 880.0 sq.ft. Supply Air: 195 CFM Ceiling Height: 9.0 ft. Supply Air Changes: 1.5 AC/hr Volume: 7,920 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 2 Actual Winter Vent.: 45 CFM Runout Air: 97 CFM Percent of Supply.: 23 % Runout Duct Size: 6 in. Actual Summer Vent.: 37 CFM Runout Air Velocity: 495 ft./min. Percent of Supply: 19 % Runout Air Velocity: 495 ft./min. Actual Winter Infil.: 36 CFM Actual Loss: 0.153 in.wg./100 ft. Actual Summer Infil.: 19 CFM {em Area U Htg - Se Clg Lat Sen HTMc. _. y- -_ -.Gain _ M:GaiJ S -Wall-I5BO-10sf-4 28.5 X 4 114 0.054 4.7 536 0.0 0 0 S -Wall-I2F-Osw 28.5 X 5 125 0.065 5.7 707 0.9 0 108 W -Wall-I5BO-10sf--4 44 X 4 176 0.054 4.7 827 0.0 0 0 W -Wall-12F-Osw 44 X 5 202.5 0.065 5.7 1,145 0.9 0 175 N -Wall-12F-Osw 28.5 X 9 214.5 0.065 5.7 1,213 0.9 0 185 E -Wall-I5BO-10sf-4 44 X 4 176 0.054 4.7 827 0.0 0 0 E -Wall-1 2 F-Osw 44 X 5 220 0.065 5.7 1,244 0.9 0 190 S -GIs-Marvin shgc-0.34 0%S 17.5 0.320 27.8 487 19.7 0 344 W -GIs-Marvin shgc-0.34 0%S 17.5 0.320 27.8 487 35.9 0 629 N -GIs-Marvin shgc-0.34 100%3 42 0.320 27.8 1,169 10.6 0 445 Floor-21 B-20 32 X 27.5 880 0.019 1.7 1,455 0.0 0 0 Floor-22D-10pm 32 ft..Per. 32 0.343 29.8 955 0.0 0 0 Subtotals for Structure: 11,052 0 2,076 Infil.: Win.: 35.8, Sum.: 18.9 839 3.964 3,326 0.312 292 262 AED Excursion: 154 People: 200 lat/per, 230 sen/per: 2 400 460 Equipment: 0 1,200 Room Totals: 14,378 692 4,152 nn.,,-k is )now A•40 Dnn LA' ut " 71 e9 Detailed Room Loads - Room 2 - Main Floor Average Load Procedure Calculation Mode: Htg. & c1g. Occurrences: 1 Room Length: 32.5 ft. System Number: 1 Room Width: 32.0 ft. Zone Number: 1 Area: 1,040.0 sq.ft. Supply Air: 327 CFM Ceiling Height: 9.0 ft. Supply Air Changes: 2.1 AC/hr Volume: 9,360 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 3 Actual Winter Vent.: 55 CFM Runout Air: 109 CFM Percent of Supply.: 17 % Runout Duct Size: 7 in. Actual Summer Vent.: 63 CFM Runout Air Velocity: 408 ft./min. Percent of Supply: 19 % Runout Air Velocity: 408 ft./min. Actual Winter Infil.: 56 CFM Actual Loss: 0,085 in.wg./100 ft. Actual Summer Infil.: 29 CFM item - j Area U Ht t _ Sen g - C1g_ Lat Sen = - Descri tion .. � ;. f. -:�, _.::.� ,. _,_:: • uaritit .... 'Value � __ . 'HTM ..._:. _ .. Loss _: HTM- �` � .:_-.-Gatn .. ' ..;Gain=. S -Wall-I2F-Osw 28.5 X 9 192 0.065 5.7 1,086 0.9 0 166 W -Wall-12F-Osw 44 X 9 360 0.065 5.7 2,036 0.9 0 311 N -Wall-12F-Osw 28.5 X 9 236.5 0,065 5.7 1,337 0.9 0 204 E -Wall-12F-Osw 44 X 9 375 0.065 5.7 2,121 0.9 0 324 S-Door-11 P 3 X 8 24 0.290 25.2 606 7.0 0 167 E-Door-11 P 3 X 7 21 0.290 25.2 530 7.0 0 146 S -GIs-Marvin shgc-0.34 0%S 8 0.320 27.8 223 19.6 0 157 S -GIs-Marvin shgc-0.34 0%S (2) 22.5 0.320 27.8. 626 19.6 0 442 S -GIs-Marvin shgc-0.34 0%S 10 0.320 27.8 278 19.6 0 196 W -GIs-Marvin shgc-0.34 0%S 36 0.320 27.8 1,002 35.9 0 1,294 N -GIs-Marvin shgc-0.34100%S 20 0.320 27.8 557 10.6 0 212 UP-Cell-I613-50 32.5 X 32 1040 0.020 1.7 1,810 1.0 0 998 Floor-20P-3010 X 16 160 0.035 3.0 487 0.3 0 45 Subtotals for Structure: 12,699 0 4,662 Infil.: Win.: 55.7, Sum.: 29.3 1,305 3.964 5,173 0.312 455 407 AED Excursion: 259 People: 200 lat/per, 230 sen/per: 2 400 460 Equipment: 0 1,200 Room Totals: 17,872 855 6,988 J 1nl..,4r,,,-,4,,,, ne.,,.,.h as 7M7 A-1A MA LU o \JI 0 � N E 0 + N aj°� j\tiz yN SW� z>' W 41 O W W 2 ti N E°� �~.:.I o N N 1�1 O ! , O f •- ll w f� (/1 CC U u1 .0 y VV to i�W rtOrt••�� �! ] � 0� J zj Z� 1W1' � N .� m ° a N "'1 ` Z MO Mrllj� o W O E W 110 N :�'_'m.in i. N A' p N �FQ- �� i Iz 5 °3��m n �zmw o (� W N O r o jar w m f V (f) h z zo 0 o m m `o Qi�m w q�l WE; i► �..I (1}Y m w l.1 zW S t a°v.. o a;. WQ b g q q q m _�v...lo q¢� z O Z Q e o®® W N Omo1 w J c0 U 3 �ZNp N• ��u�'h i s JELL V C0u Z z Iy, Z' _ 1i ,A ON _jO`F'� .� O h W o Q V ..� LLLLJJ Vl C m ;,z v�i2 W a C O O z ¢ w m a q 0o3cco F Wow Z Z 0 � W \ � �� � ow z o 11 ?w ti zNw w� ce Z a�"�a_ avv m o �z N ¢vY on LL Qo 9 ezcai¢Ov�o� ¢� o z 3 t~ilO - q�3 24i J 17 11 o W U W o m= 7 a q and 3 .0I'mo0 S) 3.9£,L4.00 S 0Ci 3 ro Lu .(;old £6'6S) J d g S a o x w -o0 p �, mn 9 cwicoi o 0o w wcd oq a xx �Z O V1 VI (J Ad Li 2 ¢ z J z 02x w z 0 sUIt W 3 U .;.".�05 0 o a oo i � w� zw ti w t 006 s'Ol __ sB ti --- ° �'0' o Z w Z k o Taw° so "uo Pm0" "1x� i = P� wo w o k—kI o wo �I __OS�� '� ��I / y ozNw 1 d ao > > o vwiw L r V•N� qj I o �la N ,.9sm �Z OIL �- •t '- a u1 �, ,�� �\ 1 1 ` 1>= Ja- hLu 0 0 ( os I 35(lOH p o a x I z N 03SOdONd ent fc °Eta o Uzi q`o aw a E6'£4 4'IOl It .--i► I ..-.-i.• ®Qp I Q Q 3, 1 � 47e zWz ¢� h I ♦ r: Qu'fZw it rO11V 3 3�w StY zuwj �o �y0 vOiIq N WwQ b co o o°xi s° Gw z Ym�do00, o ooz a tiF o I tiW z 91 i ` V o f h10! ¢ ¢zm ��wa 8o 1-W ow < ww I .'I WW Wvl y2 q� _ Inp wOo Z CO F�L m Gold 00'9l!) (tvId M „0ti,MOO N) -' 3HDI}7--=:-3HO 3Hp 3H0—ry. 3H(>3110 a 3H0—{ — I a.i: .,. ;; t +ii * � 00 JcLJJ F rn y WLU G Q M 0 2 O_3 W (L� '4�1 "00) OVOLI HON,q -LMud J Z 0 OJ Z a z W th W z J 0 4 Q- UI .J' t- CO Q z 0 a Z dQ W° S w a I U �I Xp. I I �p�; 0 910.4 W .w 0 0 i W 0 0 a o Sri 00 Co UtiGtyo • o riser '�) p01 1•i pp = 41 o X s o a W _ 0 0 0 c CO W -ix L0 o d: kph I U) pp�� x 0 0 898.3 p OP FOR'• —0-- I -Utility pole X 907.5 (141.65 plat) X 908.7 X 912.3 9� x 912.3 CONSTRUCTION ENTRANCES AT DRI VEWA YS EROSION CONTROL ADDENDUM 4--PROPOSED SILT o FENCE (Typ.) (� -Edge of trees �J�J • ht��clz- u 0 �^ ~� SERA"G o °- 0 30 60 90 "t o 00 o 10 GRAPHIC SCALE IN FEET -�-STORAGE/MATERIAL O STORAGE AREA ---Chain-link fence 24 906.2 ---PROPOSED DRAINAGE, UTILITY, INGRESS, EGRESS, AND DRIVEWAY EASEMENT SURVEYORS NOTES: DRAINAGE & -UTILITY EASEMENT 11,974 s.f. +/- FOR GATEWAY HOMES LOTS 22 & 23 BLOCK 2 WILDERNESS RUN SECOND ADDITION DAKOTA COUNTY, MN LOT 23 APPROX. IMPERVIOUS SURFACE AREAS HOUSE 1,299 s.f GARAGE 596 s.f. PORCH 40 s.f. SIDEWALK/DRIVEWAY 1.614 s.f. TOTAL 3,549 s.f. (30%) 13,058 s.f. +/- LOT 22 APPROX. IMPERVIOUS SURFACE AREAS HOUSE 1,040 s.f GARAGE 424 s.f. PORCH 50 s.f. SIDEWALK/DRIVEWAY 771 s.f. DRIVEWAY TO LOT 23 667 s.f. TOTAL 2,952 s.f. (237.) CLEOME LANE THIS DRAWING IS PROVIDED AS AN ADDENDUM TO CERTIFICATE OF SURVEY DRAWINGS, FILE NO. 22150 & 22151, DATED 0311712022, TO SHOW EROSION CONTROL MEASURES AS REQUIRED BY CITY OF EAGAN. BENCHMARK: TOP NUT OF HYDRANT ® S. W. QUADRANT OF GARDEN TRAIL & CLEOME LANE. ELEVATION = 896.43 Address: 13xx & 13xx Cleome Lane, Eagan, MN EROSION AND SEDIMENT CONTROL INSPECTION SCHEDULE.• • Every 7 days of exposed soil areas • Within 24 hours of a half inch rain event • Every 30 days of areas that are stabilized but construction activity continues • Prior to resuming construction following on extended pause in activity EROSION AND SEDIMENT CONTROL MAINTENANCE SCHEDULE.• • Within 24 hours, remove any sediment build-up on perimeter control devices exceeding 1/3 of the device height or storage capacity. • Within 24 hours maintain or replace any non-functioning pollution prevention devices or practices. • Within 24 hours or sooner if directed by City staff, remove any deposited sediment, debris, or trash from adjacent properties, streets, or sidewalks following discovery. • Within 14 days after land disturbing activities have stopped, temporarily or permanently stabilize exposed soils. FINAL STABILIZATION: Hydroseed "Sunny Delight" (90% Bluegrass, 10% Rye) I hereby certify that this survey, plan, or report was prepared by me or under my direct supervision and that I am a Licensed Land Surveyor under the laws of the State of Minnesota. Date 04/06/2022 Trace C. MCC License No. 44531