Loading...
EA180145 - Fire - Public Facility - Issued Date 11/27/2022 PERMIT City of Eagan • , , , Permit Type: Fire 3830 Pilot Knob Rd `s° % ',® Permit Number: EA180145 °-•� Eagan,MN 55122 •--- ---� EAGAN (651)675-5675 111111111111 www.cityofeagan.com * E R 1 8 0 1 4 5 Date Issued: 11/27/2022 Site Address: 1395 Cliff Rd Lot: 1 Block: 1 Addition: Joseph Connolly PID: 10-40150-01-010 1111111111111111111111111111111111111111 11111M Use: Eagan City of Water Treatment Plant * 1 0 — 4 0 1 5 0 — 0 1 — 0 1 0 Description: Sub Type: Public Facility Work Type: Fire Alarm Description: one to one fire alarm replacement Construction Type: Occupancy: Zoning: Sprinkled Area Updated Building of Permit Totals Stories: 0 0 Square Feet: 0 0 Percent of Bldg: 0 0 Comments: Fee Summary: Surcharge Based on Valuation $7.20 9001.2195 Valuation: 14,398.00 Total: $7.20 Contractor: - Applicant - Owner: UHL Company City Of Eagan 9065 Zachary Lane N 3830 Pilot Knob Rd Maple Grove MN 55369 Eagan MN 55122 (763)425-7226 This permit shall be null and void if work does not start within 180 days of issuance,or if work is suspended for 180 days or more after started. I hereby acknowledge that I have read this application and state that the information is correct and agree to comply with all applicable State of Minnesota Statutes and City of Eagan Ordinances. Applicant/Permitee: Signature ssued B :Signature L1 � �heci� a} chic U - 6:e( rco C h a�.� v: , � 'w_ a-f,Vve �o ----------------, I U For Office Use(�;(� J0 VVI C"(; j Permit C.c lei►Col �, i Permit Fee: EAGANI Date Received: I 3830 PILOT KNOB ROAD I EAGAN,MN 55122-1810 I I (651)675-56751 FAX:(851)675-5694 Staff. j buildinainsoections&citvofeaaan.00m -------------- — ' 2022 COMMERCIAL FIRE ALARM PERMIT APPLICATION Date: 11-2-22 Site Address: 1395 Cliff Road Tenant: City of Eagan - Utilities suite#: Requirements: 2 complete sets of drawings and specifications,cut sheets on materials and components Name: City Of Eagan Phone: Property:Owner Address City Zip: 3419 Coachman Pt Rd, Eagan, MN 55122 Applicant is: Owner Contractor Type of Work , Description of work: Eagan South Water Plant Fire Alarm - Uhl 022SCO28 Construction Cost: $14,398 Estimated Completion Date: 311/Zoz Name: Uhl Company License#: TS726977 Contractor Address: 9065 Zachary Lane N city: Maple Grove State: MN Zip: 55369 Phone: 763-425-7226 ContactJeff Eichenberger Email: jeffe @uhlco.com and doreens@uhlco.com _New _Remodel Work Type Addition ✓ other. One to one Fire Alarm Replacement _Alterations DESCRIPTION OF WORK: Commercial Residential Educational FEES Contract Value$14,398 X.01 $60.00 Permit Fee Minimum _ 143.98 -$ Permit Fee Surcharge=Contract Value x$0.0005 =$ 7.19 Surcharge* If the project valuation is over$1 million,please call for Surcharge 151.17 _$ TOTAL FEE You may subscribe to receive an electronic notification from the City of proposed ordinances by signing up for an email update on the City's website at wutw.citvofeagan,com/subscribe. I hereby apply for a Fire Alarm permit and acknowledge that the Information is complete and accurate;that the work will be In conformance with the ordinances and codes of the City of Eagan and with the Minnesota BuildingSre Codes;that I understan this is not a permit,but only an application for a permit,and work is not to start without a permit;that the work will be In accordance with the app an i h requires a review and approval of plans. X Jeff Eichenberger x Applicant's Printed Name A! pKdWhllfqnature FOR OFFICE USE Reviewed B �l� i*flfl 8rarnWell. Date: 022 Required Inspections: LLLRou"gh-16 X Final, Fire Alarm West Estimate Mod Material List(By System) Quote Number. 8/19/2212:00 AM Estimate/System Part Number Quantity Qty Fact Description 12V10A 2 2 10.5 Ah Sealed Lead Acid Battery-12 Vdc 12V6A5 2 2 7.6 Ah Sealed Lead Acid Battery-12 Vdc 2768-RSB 1 1 Surface Back Box-Red Steel. BPS10A 1 1 10 Amp Booster Power Supply EOL-47 2 2 EOL Resistor,47K,1/2 W FPLP14/2-lNRB-WSP 500 500 14/2 SOL UNSHIELDED FPLP PLENUM RED JACKET REEL IN A BOX FPLP18/2-1 NRB-ADV 500 500 18/2 SOL UNSHIELDED FPLP PLENUM RED REEL IN A BOX 1O64G 1 1 FACP,1 Loop,64 Intelligent devices max,2 Class B NACs,4.25A powei Misc Hardware 1 1 Miscellaneous Hardware Monitoring 12 12 Central Station Monitoring Permit Fee 1 1 Permit Fee RLCD-C 1 1 Remote LCD text annunciator with common controls.English. SA-ETH 1 1 Ethernet Programming/Diagnostics Interface,RJ45,mounts to baseplate] SA-USB 1 1 SA-USB Interface card provides USB connection to a supported printerSIGA-278 1 1 Manual Pull Station-Double Action, 1-sta e SIGA-CR 1 1 Control Rela Module.Select for either N.O.or N.C.o ration.RSIGA-CT2 1 1 Dual In ut Module.Two circuit in ut module for use with NormanSIGA-0SD 22 22 Edwards Intelli ent multi-criteria o tical smoke detector,UL/ULC SIGA-SB4 22 22 Detector Base-Standard,for 4 Inch s .box,Includes-TS4 skirt WG4RF-HVMC- - - 6 6 Outdoor Rated WaWCeilin Hom/strobe,RED w/FIRE markin , TOTAL: TOTAL: Page 1 of 1 EDWARDS Catalog Ii,Small Building Fre alarm Solutions IEE EDWARDS LIFE SAFETY §- INCIDENT MANAGEMENT Intelligent Fire � o Alarms stems _ FM 10641 101000 FDNY y COA 6227 ec®oo 7165-1657: �Eouvntaos `°"a 0244 o aa.�a LC S&M Overview. Features EDWARDS brand intelligent life safety systems offer the power • Auto-programming reduces installation time of high-end intelligent processing in configurations that deliver . Supports Signature Series intelligent modules and detectors uncomplicated solutions for small to mid-sized applications.With • Combines the Signature intelligent releasing module with intelligent detection,electronic addressing,automatic device mapping,optional Ethemet®ddhhectivity,and a full line of easily- Signature muftisensor detectors'for reliable fire suppression configured option cards and modules,these flexible systems offer • Electronic addressing with automatic device mapping versatility that benefits building owners and contractors alike. • Optional Ethemet port(SA-ETF for central station monitoring The iO64 provides one Class A or Class B intelligent device loop service,programming,diagnostics and a variety of system reports. that supports up to 64 device addresses,and two Class B Notifi- • Two programmable switches with LEDs and custom labeling cation Appliance Circuits(NACs).Optional Class A device wiring is • Supports Genesis horn silence over two wires,and UL available with the use of a module. 1971-compliant strobe synchronization The i01000 provides one Class A or Class B intelligent device • Optional multi-protocol Feld Server Bridge for interface loop that supports up to 250 device addresses.Loop controller to 3rd party Building Management Systems. modules may be added in combination to expand total system • Ground fault detection by module capacity in 250-point increments to up to 1,000 device addresses. . Supports up to eight serial annunciators,(LCD,LED-only, The i01000 panel includes four NACs that may be wired for either and graphic interface) Class A or Class B operation. • Can use existing wiring for most retrofit applications The RZI16-2 module adds even more capacity to iO installations . Upload/download remotely or locally by adding up to 16 conventional device circuits and two additional e Optional USB module for local printing or programming using notification appliance circuits.This makes them an ideal retrofit the configuration utility on a technician's laptop. solution that can accommodate new intelligent detectors,as well as existing conventional devices. • Two-level maintenance alert reporting i0 Series supports a wide range of high-end features,including: • Pre-alarm and alarm verification by point • Supports 10-Year Carbon Monoxide detectors • Adjustable detector sensitivity • R-Series remote annunciators • 4 x 20 character backlit LCD display • SIGA-REL Releasing Modules • Optional earthquake hardening:seismic Importance Factor 1.5 • Fully integrated CO detection using Signature Series • Standalone operation detectors with or without audible signaling • Alarm ON command manually activates alarm condition • Form C contacts for alarm and trouble,Form A for supervisory Page,of 8 DATA SHEET E85001-0135 Not to be used for installation purposes. Issue 20 Application Perfect for retrofits EDWARDS iO Series fife safety systems are powerful intelligent EDWARDS iO Series control panels are particularly well-suited to solutions for small to mid-sized buildings.Advanced intelligent retrofit applications.All connections are made over standard wiring technology delivers the benefits of flexible system installation, -no shielded cable required.This means that in most situations while clean and easy-to-operate user interfaces make panel existing wiring can be used to upgrade a legacy control panel to operation and system maintenance quick and intuitive. iO technology without the expense or disruption of rewiring the entire building.iO control panels also support the ingenious The smart choice RZI16-2 Zone Module,which adds up to 16 conventional circuits Signature Series electronic addressing eliminates the tedium of and two NACs.This combination easily accommodates new setting dipswitches,and automatic device mapping ensures that intelligent detection alongside existing conventional circuits, each device resides on the system at its correct location. Mean- making it an superior solution in the retrofit market. while,innovative programming allows the designer to customize the system to precisely suit the needs of the building owner. Scalable IP and Cellular Communications Optional SA-ETH module supports IP connection to a central sta- Reliability you can count on tion's Sur-Gard receiver,meeting one of the methods of communi- The inherent fault-tolerant characteristics of Analog/Addressable cation allowed by NFPA 72 as of the 2013 Edition.Several popular Technology boosts the reliability of EDWARDS fire alarm systems. third-party IP/Cellular communicators have been tested with the iO When combined with 10 Series smoke and heat detectors,these control panels and are compatibility listed to UL864.The IP/Cellular systems deliver a level of dependability not previously available for communicators meet NFPA72 2013 edition requirements for sole small to mid-sized applications.All EDWARDS systems are built to or secondary transmission paths.Using IP/Cellular communicators exacting reliability benchmarks. can reduce the cost of ownership by eliminating POTS lines.Please see the 10 control panel compatibility documentation part number Clear-cut remote annunciation 3102353-EN for a full list of compatible communicators. Remote annunciation is a strong suit of the iO Series fire alarm systems.Up to eight annunciators can be installed on a single Signals with a difference system. Compatible annunciators include a range of LED and i0 system NACs are configurable to fully support the advanced LCD models that provide zone or point annunciation,as well as signaling technology of EDWARDS Genesis and Enhanced Integ- common control capabilities.10 control panels also supports rity notification appliances.These devices offer precision synchro- graphic annunciation with optional RA Graphic Annunciator nization of strobes to UL 1971 standards.For Genesis devices, interface modules. Each interface provides common control enabling this feature allows horns to be silenced while strobes on and 32 LEDs, the same two-wire circuit continue to flash until the panel is reset. Flexibility built right in A complete line of accessories Two fully-programmable front panel switch/LED combinations provide iO Series life safety systems are supported by a complete line of an added measure of flexibility.Their slide-in labels take the mystery analog/addressable detectors,modules and related equipment. out of custom applications,and present a clean finished appearance. Consult the Ordering Information section for details. Programming and remote diagnostics Dimensions EDWARDS iO Series life safety systems are simple to set up,yet (2) (3) (4) offer advanced programming features that put these small building 07 panels into a class of their own.The auto programming feature O O O O °O quickly gets the panel operational using factory default settings. I° ( 13 00 O Basic zone and point settings can be programmed through the O O front panel interface,so the system is up and running in no time. i O O O For more advanced system configuration and correlation groups °t ( D4 programming,iO Series systems interface to a PC running com- O patible iO-CU software.This option offers full system configuration ° '° 1 as O O in the familiar Windows®operating environment.Connection is ° made to a laptop through the panel's optional RS-232 communi- cations port,which can also be used to connect a system printer. �DO Among the many innovative features of iO Series control panels is the optional network card.This module provides a standard (1)Surface Mounting Holes (3)Backbox with Door Attached 10/100 Base T Ethernet®network connection that permits access (2)Semi-flush mounting Holes (4)Backbox with door and trim kit attached. to the control panel from any remote location with the correct communications protocols.The connection can be used to Panel dimensions,In(cm) download to the panel from the iO-CU,or upload and view Mode] Di• 02 D3 D4 Ds• De D7 D9 D9 system reports using the iO-CU. 101000 28.0 3.95 9.0 22.0 15.75 10.25 4.4 29.2 2.7 p,.,) (9.a) (22.9) (55.8) (40.0) (zs.o) (11.1) V1.6) (6.8) Available system reports include:Correlation groups, Device �4 21.5 3.85 7.5 15.5 14.25 10.25 4.5 21.7 2.7 (54.6) (9.8) (19.0) (39.4) (36.2) (26.0) (11.4) details, Device maintenance,History,Internal status,System •Add 1-1/2 in.(3.81 cm)to D1 and D5 dimensions for trim kit.The trim kit configuration,System status,Walk test, Dialer,and CO runtime. provides 0.75 Inches(1.9 cm)of trim to the top,bottom,and sides of the backbox. Page 2 of 8 D A T A S 1-1 E E T E85001-0135 Not Yo 6f- used fog in,tailation purposes. Issue2.0 System Layout i01000 Any combination of two single-or dual Signature loop modules ----------------------------------------------------------------------- Standard Loop:250 points(one expansion slot) i0-SDC2 Expander,Loop 1 of 2:250 points Up to 125 sensors and 125 modules per loop (one expansion i0-SDC1 Expander Loop:250 points(one expansion slo iO-SDC2 Expander,Loop 2 of 2:250 points t,Up to 20,000 feet of wiring per loop Four Class B or two optional Class A Four Class B or two optional Class A NACs Optional 10 A or 6.5 A Booster FFrEthernet(SA-ETF)• DACT/Dialer(SA-DACT) Up to eight remote annunciators RS-232(SA-232 or SA-USB)" FSixteen Conventional IDCs, Relays:Two Form C,one Form A , 'two additional NACs with F016-2 module Each 101000 panel has room for up to two Signature loop controller modules in any combination of single or dual 250-device loops.i01000 loops support 125 detectors and 125 modules. Panel Layout ' a n 3 00V 80 s 1 eo a f 1064 2 Zjki 0 8 f cir Loop supports up to 64 intelligent devices of any 4 to Up to 20,000 feet of wiring. Y v tt 12 t - 13 Two Class B or two optional Class A Optional 10 A or 6.5 A Booster Power Supply = ° ytl - .. 1 Transformer Wring Up to eight remote annunciators 2 'Main AC� ��•� g block&fuse holder 3 RS-232 card connector 03)' Ethernet(SA-ETH)' 4 Dialer card connection(J8) DACT/Dialer(SA-DACT) A 5 Ethernet card connector(Ji) I 6 Main circuit board RS-232(SA-232 or SA-USB)" 7 Panel backbox enclosure Relays:Two Form C,one Form A 8 Operator interface Sixteen Conventional IDCs, 8 SLC card connector(J7) two additional NACs with 10 Class A card connector(J2) Each 1064 panel ships with one Signature loop RZI16-2 module 11 Tie wrap mounts controller that supports 64 devices of any type. 12 LED expander connector(J6) This13 Standby batteries panel s device capacity cannot be expanded. `SA-ETH supports:(1)remote connectivity for diagnostics&programming,(2)Central station monitoring to Sur-Gard IP Receivers. **RS-232 supports:(1)Printer.(2)Programming Interface,(3)Use of Field Server BrHdge(SA-FSB)for 3rd party Building Management Systems Interface. Page 3 of 8 DATA SHEET E85001-0135 Not to be used,for installation purposes. Issue 2.0 Wiring & Configuration Signature device loop Auxiliary&smoke power outputs(TB3) The system provides one Signature device loop circuit with a total The control panel provides two auxiliary power Tea capacity of 125 detectors and 125 module addresses.The loop outputs that can be used for powering ancillary circuit is supervised for opens,shorts,and grounds. equipment such as remote annunciators and two (1) No peeMcations wire smoke detectors. Aux 2 can be software NC s 101000 1054 selected to operate continuously.The circuit is specifisupervised for shorts and grounds. Device loops One Class B or A One Class B or A loop, (2) NO loop,supporting 125 supporting 64 devices of Circuit specifications 0 detectors and 125 any kind. Circuit voltage 21.9 to 28.3 V modules.Expandable to range 0 NC four loops. Resettable circuit 24 VDC nominal at 500 mA (3) 0 Communication Maximum 20 V peak-to-peak (Aux power 2) NO line voltage Continuous circuit 24 VDC nominal at 500 mA. 0 Circuit current 0.5 A max (Aux power 1) Use this circuit for powering to Circuit 660 total,0.5 NF,max two-wire smoke detectors. impedance (4) Isolators 64 maximum Note:Any current above 0.5 amp connected to both Aux 1 and 2 will reduce the total available NAC power by that O Signal Supported on a system-wide basis(all device loops) amount. Synchronization when using a SIGA-CCI S or SIGA-MCC1 S module (1)Trouble and Genesis or Enhanced Integrity notification ap- Alarm,trouble,and supervisory relay(TB3) (2)Supervisory pliances. The trouble relay is normally-open,held closed, (3)Alarm Clan ewMng Clan anop y d ens on antrouble event or when the panel is de-energized.The supervisory relay is (4)Smoke/Aux m m normally-open,and closes on any supervisory Laop 1 SEC*� Dete Lhre Loop 1 SEC* event.The alarm relay changes over on any Leap,pw - Loop 1 PRI ' + alarm event. + + Loop Loop Lapp Laop d= L ce Loop card device device Loopaso OaeLne Relay specifications Alarm Trouble Supervisory Type Form C Form A Notification appliance circuits(TB2) Voltage 24 VDC at 1 A resistive 24 VDC at 1 A resistive i01000 control panels come equipped with four notification ap- Relay circuits can only be connected to power-limited sources. pliance circuits.iO64 control panels come with two NACs.Each circuit can be individually configured for continuous,temporal, synchronized,and coded output. Annunciator loop(TB4) Specifications 101000 1064 The control panel provides a connection for up to eight serially Circuit Type 4 Class B or 2 Class A 2 Class B or 2 Class A driven and supervised remote annunciators. with SA-CLA module Circuit specifications Voltage 24 VFWR Current 6.0 A total,2.5 A max. 3.75 A total,2.5 A max. Device loops Class B(Style Y)or Class A(Style Z) per circuit at 120/230 per circuit at 120/230 Circuit voltage 2.55 V VAC 60 Hz. VAC 60 Hz. Circuit current 30 mA max 5.0 A total,2.5 A max. 3.0 A total,2.5 A max. Circuit Up to 8 annunciators or 4000 feet per circuit at 230 VAC per circuit at 230 VAC impedance 50 Hz. 50 Hz. Impedance 26 O total,0.35 pF max EOLR 15 K 0,Y2 W Class B Class A Synchronization Supported system-wide Channell Channel Channell Channel Claw a wMng Clow A wiring 0 NAC,- + + 0 NAC, + + Tao .r13<t 0 NAC,+ 0 NACt+ _ AnnllnClator Annunciator 0 EOLR �'i^a' + + 0 w'a + + 0 CH1(+)IN CH1(+)IN NAc2+ + _ CH1(—)IN CH1(—)IN ret TB2 0 NAC3- + + 0 NAP+ + CH2(+)IN CH2(+)IN 0NAca + + EOLR _ CH2(—)IN CH2(—)IN 0 NAC4+ 0+ res TSS Marking Indicates output signal polarity when the circuit is active.Polarity reverses when the circuit is not active.Wire notification appliances accordingly.Notification appliance polarity shown In active state. Page 4 of 8 DATA SHEET E85001-0135 Not to be used foi installation purposes. Issue2.0 Option Cards EDWARDS iO Series panels are supported by a complete line RZ116-2 Remote Zone Interface Module of modules and related equipment that enhance performance FEW" and extend system capabilities.Option cards plug directly into the control panel main circuit board or are connected to it with a ribbon cable.After installation,terminals remain accessible.The cabinet provides ample room for wire routing,keeping wiring neat at all times. low Single and Dual Loop Controller Cards The iO-SDC1 is a single loop controller card that can be used with The RZI16-2 Addressable Remote Zone Interface Module is an the iO64 as a replacement for the standard 64-point loop,or with addressable device that provides connections for sixteen Class B the i01000 as a 250-point expansion module. Initiating Device Circuits and two Class B Supervised Output Circuits.The inputs and outputs can be configured individually The iO-SDC2 is a 500-point dual loop controller card for the for several device types. i01000 that provides two SLC circuits,each with 125 detector addresses and 125 module addresses. It requires 18 consecutive addresses on the Signaling Line Circuit (SLC).Addresses are assigned electronically.There are no address Specifications 10-SDC1 10-SDC2 switches to set. i01000:one loop, The RZI16-2 incorporates two 8-segment DIP switches that 250 device address i01000:two loops, are used to select the Alarm or Supervisory default device type Device Addresses 1064:64 addresses 500 device addresses for each of the 16 IDC circuits.The module also includes one Wiring Class B or Class A 4-segment DIP switch used to select the default Relay or NAC Operating Voltage 24 VDC output device type. Device types other than the default are Operating Current Standby:55 mA i Standby:45 mA accomplished through programming. (fully loaded loop) Alarm:80 mA Alarm:70 mA Note:These ratings do not include the use of two-wire smoke modules. RZ116-2 Specifications Communication Voltage Line Voltage Max.20.6 V peak-to-peak 24V/Aux nominal: 24 VDC Terminal Rating 12 to 18 AWG(0.75 to 2.5 mmg Supervisory current: 250 rhA at 24 VDC nominal Circuit Current 0.5 A max. Alarm Current 1000 mA Max total loop resistance 660 24V/Aux minimum: 18.4 VDC Max total loop capacitance 0.5 NF 24V/Aux maximum: 26.4 VDCNAC1,NAC2 nominal: 24 VDC 64 isolators maximum per loop(total both Current Isolators Isolator bases and modules) Ground Fault Impedance 0 to 5 k0 Standby current for 4.7 k EOL(U.S.) 4.8 mA/circuit 32 to 120°F(0 to 49°C) Standby current for Operating Environment 0 to 93%noncondensing at 90°F(32°C) 3.9 k EOL(Canada) 5.7 mA/circuit Alarm current at nominal voltage 31.1 mA/circuit Relay outputs SA-ETH Ethernet Interface CardAP Communicator Quantity 2 The SA-ETH card provides a standard 10/100 Base T Ethernet Type Rating(pilot duty) Programmable 24 VDC at 2.5 A network connection for connecting to an intranet,a local network, Input circuit wiring 25 0 per wire or the Internet.The card supports IP connectivity for monitoring resistance services by a supervising station to meet Initiating device circuits NFPA 72 Chapter 26. The Ethernet 16et card uses EOL resistor 4.7 k0(U.S.);3.9 k0 Canada the FIBRO protocol to communicate with Zone voltage 22.78 V for 4.7 k0(U.S.) Sur-Gard System receivers(see below).The 22.08 V for 3.9 k0(Canada) card can be used to download configuration Alarm current 31.1 mA/channel at nominal voltage programming from the 10-CU tothe panel. Alarm impedance range <680 0 Trouble impedance range >5.55 k0 The Ethernet card is installed on the plastic Supervised output circuits assembly and connects to the main circuit EOL resistor 15 k0 board via a ribbon cable. Quantity 2 Short circuit detection <2.6 k0 SA-ETH specifications Open circuit detection >61.9 k0 Ethernet 10/100 Base-T Contact ratings 24 VDC at 2.5 A(5 A for two NACs) Operating environment Compatible cabinets MFC-A,101000,APS Temperature 32 to 120°F(0 to 49°C) Humidity 0 to 93%RH,noncondensing at 90°F(32°C) Compatible Sur-Gard Receivers SG-System I,II,III,IV and 5 Page 5 of 8 DATA SHEET E85001-0135 Not to be used for installation purposes. Issue2.0 SA-DACT Dialer SA-232 RS-232 interface The SA-DACT provides communications between the control The SA-232 card provides an RS-232 panel and the central station over a telephone line system. It interface with iO panels. It can be used transmits system status changes(events)to a compatible digital for connecting a printer to the control alarm communicator receiver over the public switched telephone panel to print system events.The card network.The dialer is capable of single,dual,or split reporting also can be used for connecting a of events to two different account and telephone numbers.The computer to download a configuration modem feature of the SA-DACT can also be used for uploading program from the iO-CU to the and downloading panel configuration,history,and current status control panel. to a PC running the iC-CU. The RS-232 card is installed on the The dialer phone lines connect to connectors plastic assembly and connects to the W"V on the dialer's main circuit board.Phone line �"�� - main circuit board via a ribbon cable. 1 connects to connector J4 and phone line 2 Pl— ws,l�w connects to connector J1. SA-232 specifications Operating voltage Standard EIA-232 ® Terminal rating 12 to18 AWG(0.75 to 2.5 sq mm) -,oo The SA-DACT queues messages and Operating environment 00 , transmits them based on priority(alarm, Temperature 32 to 120°F(0 to 49°C) . supervisory,trouble,and monitor).Activa- Humidity 0 to 93%RH,noncondensing at 90°F(32°C) ❑❑ az moo�l�e•° ° tions are transmitted before restorations. ❑ oijBoo °° �g ❑ The SA-DACT is installed on the plastic assembly and connects to the main SA-CLA Class A Module(iO64 only) circuit board via a ribbon cable. The SA-CLA card provides Class A capability for NAC wiring. Its terminal block provides the wiring connection for NAC return SA-DACT specifications wiring.The card is required for annunciator Class A wiring even Phone line type One or two loop-start lines on a public, though this wiring does not return to the SA-CLA card.The SA- switched network CLA is compatible with i064 control panels only.i01000 panels Phone line connector RJ-31/38X(C31/38>0 are Class A Ready.The SA-CLA is installed directly to the control Communication formats Contact ID(SIA DC-05) panel circuit board using its plastic standoffs and plug connection. Operating environment Temperature 32 to 120°F(0 to 49°C) SA-CLA specifications Humidity 0 to 93%RH,noncondensing at 90°F Operating voltage 24 VFWR (32°C) Operating current 3.75 A FWR total at 120/230 VAC 60 Hz 3.0 A FWR total at 230 VAC 50 Hz Compatible DACRs 2.5 A max per circuit Receiver Models Formats Circuit impedance 26 ohms,0.35uF Ademco 685 Contact ID Terminal rating 12 to18 AWG(0.75 to 2.5 sq mm) FBII CP220 Contact ID Operating environment Osborne-Hoffman OH 2000 Contact ID Temperature 32 to 120°F(0 to 49°C) Bosch D6600 Contact ID Humidity 0 to 93%RH,noncondensing at 90°F(32°C) Silent Knight 9800 Contact ID Sur-Gard SG-MLR1,MLR2 Contact ID D16LAO LED Display Expander(101000 only) The D16L-i0 IED Display Expanders provide LED annunciation for up to 16 zones. It provides two LEDs for each zone.Two D16L-i0 The SA-USB Interface Card LED display expanders can be installed in each i01000 panel. The SA-USB Interface Card provides a USB connection to a sup- ported printer or a connection to a PC.The card can be used for (3) (4) connecting a printer to the control panel to print system events. (2) zone (Z) zone f7 (1)LED 1 The card can also be used for uploading and downloading panel (2)LED 2 configuration,historty,and current status to a PC running the (3)LED Expander 1 configuration utility(CU). (4)LED Expander 2 (5) SA-USB specifications and c rouble one LEDs Operating voltage 24VDC Current Standby/Alarm 13 mA,max 20mA Universal Serial Bus 1 USB Type A-host port J3(printer connection) (USB)ports 1 USB Type B-device port J4(CU connection) Supported Printer PT-1S Printer communication z speed 9600 baud (5) Operating environment Temperature 32 to 120°F(0 to 49°C) e Humidity 0 to 93%RH,noncondensing Page 6 of 8 DATA SHEET E85001-0135 Not to be used for installation purposes. Issue2.0 Specifications 1064 101000 Device loops 1 loop Class B or Class A(Styles 4,6,7)supporting up to 1 loop,expandable to 4,Class A or B(Styles 4,6,7), 64 device addresses(any combination of detectors and each loop supporting up to 250 device addresses(125 modules) detectors and 125 modules max.).Addresses 1 to 125 are Maximum T-taps:63 for detectors and addresses 126 to 250 are for modules (each device can be on its own branch) Maximum T-taps/loop:124 Notification appliance 2 Class B(Style 1),Class A(Style Z)optional 4 Class B(Style Y)or 2 Class A(Style Z) circuits 3.75 A FWR total at 120/230 VAC 60 Hz 6.0 A FWR total at 120/230 VAC 60 Hz 3.0 A FWR total at 230 VAC 50 Hz 5.0 A FWR total at 230 VAC 50 Hz 2.5 A FWR each max.per circuit 2.5 A FWR each max.per circuit Primary power 120 VAC,60 Hz,1.3 A max. 120 VAC,60 Hz,2.0 A max. 230 VAC,50-60 Hz,0.62 A max. 230 VAC,50-60 Hz,0.97 A max. Base panel current standby 155 mA 172 mA Base panel current alarm 204 mA 267 mA Input zones 16 max. 32 max. Remote annunciator 8 drops max.,RS-485 Class B,Class A is optional 8 drops max.,RS-485 Class A or B Data line length:4,000 ft.(1,219 m) Data line length:4,000 ft.(1,219 m) Operating voltage 24 VDC panel Auxiliary power output Aux power 1:500 mA,24 VDC(1 A possible If you reduce total available NAC power by 500 mA) circuit Aux power 2:500 mA,24 VDC Output:28.3 to 21.9 VDC,special application Note:For a list of compatible devices,see the 1064 and'101000 Series Compatibility List(P/N 3102353-EN) Loop circuit Maximum loop resistance:66 0 Maximum loop capacitance:0.5 NF Communication line voltage:Maximum 20.6 V peak-to-peak Operating current(fully loaded loop)Stand by:55 mA/45 mA Alarm:125 mA/115 mA(not including two-wire smoke modules) Circuit current:0.5 A max.Style 4,6,and 7 wiring Max.resistance between isolators:Limited only by overall wire run lengths 64 isolators maximum per loop(total both isolator bases and modules) Batteries Type:Sealed lead acid Voltage:24 VDC Charging current:2.47 A max.Amp hour capacity:26 Ah Standby operation:24 hour or 60 hour Placement:Up to two 10 Ah batteries will fit in the iO64 control panel cabinet and two 18 Ah batteries will fit in the i01000 control panel cabinet.If larger batteries are required,use an EDWARDS battery cabinet. SA-DACT dialer Phone line type:One or two loop-start lines on a public,switched network Phone line connector:RJ-31/38X(C31/38)q Communication formats:Contact ID(SIA DC-05) Operating current Standby/Alarm:41 mA Max.:100 mA FCC registration number:GESAL01 BSADACT Industry Canada Registration number:3944A-SADACT Ringer equivalence number:0.1 B Ground fault impedance 0 to 5 k(1 Alarm contact Form C N.O.24 VDC at 1 A(resistive load) Trouble contact Form C 24 VDC at 1 A(resistive load) Supervisory contact Form A N.O.24 VDC at 1 A(resistive load) Environmental Temperature:0 to 49°C(32 to 120°F)Relative humidity:0 to 93%noncondensing Terminal rating All terminals rated for 12 to 18 AWG(0.75 to 2.5 mm� Page 7 of 8DATA SHEET E85001-0135 Not to be used for installation purposes. Issue2.0 Ordering Information Part Description 101000 Fire Alarm Systems 101000G Four loop system with one 250-point loop installed.110v,gray door. EDWARDB 101000G-2 Four loop system with one 250-point loop installed.230v,gray door. 101000G-2-PG Four loop system with one 250-point loop installed.230v,gray door,Portuguese. 101000G-2-SP Four loop system with one 250-point loop installed.230v,gray door,Spanish. LIFE SAFETY&INCIDENT MANAGEMENT 101000G-CA Four loop system,one 250-point loop installed.110v,gray door,LED strips,Canada. I01000GD Four loop system,one 250-point loop installed.110v,gray door,with dialer. Contact us 101000G-F Four loop system,one 250-point loop.110v,gray door,LED strips,French Canada. Phone: 800-655-4497(Option 4) 101000G-PG Four loop system with one 250-point loop installed.110v,gray door,Portuguese. Email: edwards fire®carrier com 101000G-SP Four loop system with one 250-point loop installed.110v,gray door,Spanish. Website: edwardsfiresafe com 101000R Four loop system with one 250-point loop installed.110v,red door. 8985 Town Center Pkwy 101000R-2 Four loop system with one 250-point loop installed.230v,red door. Bradenton,FL 34202 101000RD Four loop system,one 250-point loop installed.110v,red door,with dialer. SA-TRIM2 101000 Flush mount trim,black. 02021 Carrier Al Rights Reserved. 1064 Fire Alarm Systems 1064G One loop system with one 64-point loop installed.110v,gray door. 106413-2 One loop system with one 64-point loop installed.230v,gray door. 1064G-2-PG One loop system with one 64-point loop installed.230v,gray door,Portuguese. 1064G-2-SP One loop system with one 64-point loop installed.230v,gray door,Spanish. 1064GD One loop system,one 64-point loop installed.110v,gray door,with dialer. I064GL One loop system,one 64-point loop installed.110v,gray door,English Canada. 1064GL-F One loop system,one 64-point loop installed.110v,gray door,French Canada 1064G-PG One loop system with one 64-point loop installed.110v,gray door,Portuguese. 1064G-SP One loop system with one 64-point loop installed.110v,gray door,Spanish. 1064R One loop system with one 64-point loop installed.110v,red door. 1064R-2 One loop system with one 64-point loop installed.230v,red door. 1064RD One loop system,one 64-point loop installed.110v,red door,with dialer. SA-TRIM1 iO64 Flush mount trim,black Option Cards 10-SDC1 Expansion module,one 250-device loop. 10-SDC2 Expansion module,two 250-device loops,500 devices total.For iO1000 only. RZI16-2 Remote Zone Interface Module.16 Class B IDCs,2 Class B Output.Includes bracket. SA-DACT Dual Line Dialer/Modem,supports Contact ID,mounts in cabinet on base plate. SA-232 RS-232 Serial Port for connection to printers&computers,mounts in cabinet. SA-ETH Ethernet Port,IP Communicator,mounts in cabinet on base plate. SA-CLA Class A adapter module.Provides Class A capacity on NACs.Mounts in cabinet on main board.1064 systems only. SA-FSB Feld Server Bridge for connection to 3rd Party Building Management Systems. Supports BACnet and Modbus protocols.Mounts in the MFCA cabinet using the FSB-BRKT2 mounting plate.See separate SA-FSB datasheet E85010-0156 for additional information. SA-USB RS-232 Serial port for connection to printers&computers,mounts in cabinet. D16L-i0-2 LED Annunciator module,16 X 2-LED zones(4 programmable for sup). Mounts in cabinet to right of LCD display for zones 17-32.For i01000 only. D16L-i0-1 LED Annunciator module,16 X 2-LED zones(4 programmable for sup). Mounts in cabinet to left of LCD display for zones 1-16.For i01000 only. D8RY-10-2 Canada only:LED Annunciator module,two LEDs per zone,16 zones(4 alarm only, 8 supervisory only,4 alarm or supervisory).Mounts in cabinet.For i01000 only. D8RY-i0-1 Canada only:LED Annunciator module,two LEDs per zone,16 zones(4 alarm only, 8 supervisory only,4 alarm or supervisory).Mounts in cabinet.For i01000 only. Accessories CTM City Tie Module.2-gang.Connection to a local energy fire alarm box. MFC-A Multifunction Fre Cabinet,8°x 14°x 3.5°-red. SIGA-REL Releasing Module PT-1S System Printer BC-1 Battery Cabinet.14.0°x 18.25°x 7.25°.Holds two 12V24A batteries. BC-1 R Battery Cabinet-Red.14.0°x 18.25°x 7.25°.Holds two 12V24A batteries. BC-1 EQ Seismic hardening Kit for 10 series panels.Includes battery hardening for BC-1 enclosure and components to harden panel internal components. Programming Tools i0-CU IO Series configuration and diagnostics utility. 260097 RS232 cable,4 conductor,DB9 PC interface Ss Page 8 of 8 D A T A S H E E T E85001-0135 Not to be used foi installation purposes. issue 2.0 EDWARDS Catalog ® Intelligent Initiating Devices EDWARDS EK: LIFE SAFETY �" INCIDENT MANAGEMENT Intelligent Smoke Detector SIGA-OSD �� ► �I O7272.1657: 0511 Overview Standard Features The Signature Optica Series SIGA-OSD smoke detector • Multi-criteria optical smoke sensing technology brings advanced optical(photoelectric)technology to a practical . Wide 0.5 to 4.36%/ft.(1.6 to 13.6%/m)smoke obscuration design that increases efficiency,saves installation time, cuts costs,and extends life safety and property protection • Uses Existing Wiring capabilities.Continuous self-diagnostics ensure reliability . Integrated nuisance rejection reducing unwanted alarms over the long-haul,while environmental compensation helps from general cooking particulates reduce maintenance costs. • Listed to UL 268 7th edition Like all Signature Optica Series detectors,the SIGA-OSD is an intelligent device that gathers analog information from multiple • Automatic Device Mapping optical sensors,converting this data into digital signals. Utilizing e Up To 250 Total Signature Addresses Per Loop dual optical wavelengths combined with multiple detection angles, • Two Levels of Environmental Compensation the SIGA-OSD differentiates particles that are not representative of actual smoke.Particle data is input into digital filters which • Two Levels of Dirty Detector Waming feed a series of ratios removing signal patterns that are typical of nuisance sources,thus reducing unwanted alarms.To make an Twenty Pre Alarm Settings alarm decision,the detector's on-board microprocessor measures • Five Sensitivity Settings and analyzes all optical sensor readings and compares this . Non-Volatile Memory information to preprogrammed settings. • Electronic Addressing • Automatic Day/Night Sensitivity Adjustment • Bicolor(Green/Red)Status LED • Standard, Relay,Fault Isolator,and Audible Mounting Bases • Sensor Markings Provide Easy Testing Identification Note:Some features described here may not be supported by all control systems.Check your control panel's Installation and Operation Guide for details. Page 1 of 4 DATA SHEET E85001-1001 Not to be used for installation purposes. Issue 1.4 Application Testing & Maintenance The SIGA-OSD detects particles from a wide range of combustion Each detector automatically identifies when it is dirty or defective sources and will trigger an alarm when smoke density in the and causes a"dirty detector"message.The detector's sensitivity chamber reaches preprogrammed level.Thanks to its high- measurement can also be transmitted to the loop controller, performance reflective response technology,the smoke sensor A sensitivity report may be printed to satisfy NFPA sensitivity responds quickly and reliably to a wide range of fire types, measurements,which must be conducted at the end of the first including both fast and slow burning fires fueled by combustibles year and every two years thereafter. typically found in modern multi-use buildings. The user-friendly maintenance program shows the current state of each detector and other pertinent messages.Single detectors may be turned off temporarily from the control panel.Availability of Compatibility maintenance features is dependent on the fire alarm system used. The SIGA-OSD detector is compatible only with control panels using a Signature Loop controller. Accessories InstallationDetector mounting bases have wiring terminals that are — accessible from the"room-side"after mounting the base to the Signature Series detectors mount electrical box.The bases mount to North American 1-gang boxes to North American 1-gang boxes, and to 31/2 inch or 4 inch octagon boxes, 11/2 inches(38 mm) 3-1/2 inch or 4 inch octagon d ® deep.They also mount to European BESA and 1-gang boxes with boxes,and to 4 inch square Self-ibc"tab 60.3 mm fixing centers.The SIGA-SB4,SIGA-RB4,and SIGA-1134 electrical boxes 1-1/2 inches mount to North American 4 inch sq.electrical boxes in addition to (38 mm)deep.They mount to the above boxes.They include the SIGA-TS4 Trim Skirt,which is European BESA and 1-gang used to cover the"mounting ears"on the base.The SIGA-AB4G boxes with 60.3 mm fixing low LIMmabatbr mounts to a 4 inch square box only. centers.See mounting base installation and wiring for r `is more information. Sensing and reporting technology SIGA-AB4W/LF SIGASB SIGA-IB SIGA-RB SIGA-LED The microprocessor in each detector provides additional Audible Base Standard Base Isolator Base Relay Base Remote LED benefits–Self-diagnostics and History Log,Automatic Device Remote LED SIGA-LED-The remote LED connects to the Mapping,and Fast,Stable Communication. SIGA-SB or SIGA-SB4 Standard Base only. It features a North Self-diagnostics and History Log-Each Signature Series American size 1-gang plastic faceplate with a white finish and detector constantly runs self-checks to provide important red alarm LED. maintenance information.The results of the self-check are SIGA-TS4 Trim Skirt-Supplied with 4 inch bases,it can also automatically updated and permanently stored in the detector's be ordered separately to use with the other bases to help hide non-volatile memory surface imperfections not covered by the smaller bases. Automatic Device Mapping-The loop controller learns where Sounder Bases-Signature Series sounder bases are designed each device's serial number address is installed relative to other for use where localized or group alarm signaling is required. devices on the circuit.The mapping feature provides supervision of each device's installed location to prevent a detector from being • SIGA-AB4G bases provide sounder capability to Signature reinstalled(after cleaning,etc.)in a different location from where it Series to heat and smoke detectors.They are not intended was originally. for use with combination carbon monoxide detectors in Fire-plus-CO mode. Fast Stable Communication-On-board intelligence means . SIGA-AB4GT bases provide sounder capability to Signature less information needs to be sent between the detector and the Series smoke and heat detectors,as well as carbon loop controller.Other than regular supervisory polling response, monoxide detectors when used with a SIGA-TCDR Temporal the detector only needs to communicate with the loop controller Pattern Generator. when it has something new to report. • SIGA-AB4G-LF bases provide 520 Hz low frequency sounder capability to Signature Series smoke and heat detectors,as well as carbon monoxide detectors when used with a SIGA-TCDR Temporal Pattern Generator.The SIGA-AB4G-LF is suitable for applications requiring low frequency audible tones. Page 2 of 4 DATA S H E E T E85001-1001 Not to be used for installation Mlmoses. Issue 1.4 Typical Wiring The detector mounting bases accept#18 AWG(0.75mm2),#16 Audible Sounder Bases,Fire Mode (1.0mm2),#14 AWG(1.5mm2),and#12 AWG(2.5mm2)wire sizes. AB4GT,AB4G,AB4G-LF sounder bases Sizes#16 AWG(1.0mm2)and#18 AWG(0.75mm2)are preferred for ease of installation. Standard Detector Base,SIGA-SB,SIGA-SB4 Sloe-AB4GT o o SAG►-AB4G-LF: SIGA-AS4G. ®dumper® Output Made This is the basic mounting SIGs-AB4G-LF. Default-Fire base for EDWARDS Signature J(-) z Volume Setting CuVremoveJumper g Default=High for Fire plus CO Series detectors.The SIGA- resistance Cut/remove LED Remote LED is supported Jumper for sIGA-ABao: low dB ® ® Tone Setting by this Base. o� Default=Temporal so.&G. our of MRMT Cuttremove Jumper Tenn Description for Steady 1 Not Used2 DATA IN/OUT3 Not Used4 Reemote ATA IN(LED(-) DATAOUT(-) 5 Remote LED(+) 6 Not Used24 Vdc in _ DATA IN(+) DATA OUT(+I - 24 Vdo out 7 DATA OUT(-) From Signature Controller To Next Device From power supply or Previous base+ + To next fume or EOL relay or Previous Device Data in - Data out Isolator Detector Base,SIGA-IB,SIGA-1134 From Signature Controller + to next Signature device or previous device+ This base includes a built-in line fault isolator for use on Class A circuits.A detector must be installed for it to operate.The isolator base does not support the SIGA-LED Remote LED. Warnings & Cautions The isolator operates as follows: ° This detector does not operate without electrical power. -a short on the line causes all d As fires frequently cause power interruption,discuss isolators to open within 23 msec. o ° ° O further safeguards with the local fire protection specialist. -at 10 msec intervals,beginning o on one side of the Class A ° ° This detector does not sense fires in areas where smoke ° o�� cannot reach the detector.Smoke from fires in walls, circuit nearest the loop DATA IN(-) Z roofs,or on the opposite side of closed doors may not controller,the isolators DATA OUT pp Y close to provide the reach the detector. next isolator down DATA IN(+) DATA OUT(+) In Canada,install according to CAN/ULC-S524 Standard for the line with Ower. From Signature Controller To Next Device p or Previous Device the Installation of Fire Alarm Systems,CSA C22.1 Canadian -when the isolator next Tem option Electrical Code,and the local authority having jurisdiction. 1 Not Used to the short Closes,It 2 DATA IWOUT(+) reopens within 10 msec. 3 DATA IN(-) 4 Not Usad The process repeats beginning 5 Not Asea p � g on 6 DATA OUT(-) the other side of the loop controller. 1 7 Not Used Relay Detector Base,SIGA-RB,SIGA-RB4 This base includes a relay. � � N Nomxffo- Ckowd Open Normally Open or Normally Closed operation is selected during installation.The dry contact is rated for 1 amp e (pilot duty)®30 Vdc.The ° relay's position is supervised to avoid accidentally jarring it DATJINO �� L our c-) out of position.The SIGA-RB can be operated as a control DATA IN(+) DATA Our(+) Frwn SIgnatwe conuouer To Next Device relay If programmed to do so or PrWow Device Term Desoription at the control panel.The relay 1 Normally Open base does not support the CONTACT RATING 2 DATAIN/OLT(+) SIGA-LED Remote LED. 1.o Amp® voc 3 Common (PAot Duty) 4 DATA IN(-) 5 Not Used 6 Normally-Closed 7 DATA OUT- Page 3 of 4 DATA SHEET E85001-1001 Not to be used for installation Purposes. Issue 1.4 Dimensions LIFE SAFETY&INCIDENT MANAGEMENT ,e3e Contact us ® 2318 Phone: 800-655-4497(Option 4) JWdZM Email: edwardsfire@carriercom ' Website: edwardsfiresafet.ggirn � 8985 Town Center Pkwy Bradenton,FL 34202 `¢3esa ©2021 Carrier Al rights reserved. Specifications Operating voltage 15.20 to 19.95 VDC Normal operating current 32 pA Alarm current 45 pA Smoke Sensitivity Range UL/ULC:0.5 to 4.36%/ft.(1.6 to 13.6%/m)obscuration Vibration level 10 to 35 Hz,with an amplitude of 0.01 in. Air velocity 0 to 4,000 ft./min(0 to 20 m/s) Wall mounting 12 in.(305 mm)max.from ceiling Compatible bases See Ordering Information Compatible detector testers Testifire 1000,Testifire 2000 Operating environment 32 to 120°F(0 to 49°C),0 to 93%RI-I;noncondensing Construction High Impact Engineering Polymer,White Storage temperature -4 to 140°F(-20 to 60°C) Environmental compensation Automatic Agency Listings CAN/ULC-S529,UL 268-7,UL 268A,CSFM Ordering Information catalog Number Description Ship Wt lbs(k9) SIGA-OSD Intelligent Optical Smoke Detector 0.4(0.16)— Accessories .4(0.16)Accessories SIGA-SB Detector Mounting Base-Standard SIGA-SB4 4-inch Detector Mounting Base c/w Trim Skirt SIGA-RB Detector Mounting Base w/Relay SIGA-R134 4-inch Detector Mounting Base w/Relay,c/w Trim Skirt 0.2(.09) SIGA-IB Detector Mounting Base w/Fault Isolator SIGA-1B4 4-inch Detector Mounting Base w/Fault Isolator,c/w Trim Skirt SIGA-LED Remote Alarm LED(not for EN54 applications) SIGA-AB4G Audible(Sounder)Base for Fre Detectors 0.3(0.15) SIGA-A64G-LF Low Frequency Audible(Sounder)Base for CO and/or Fre Detectors 0.3(0.15) SIGA-AB4GT Audible(Sounder)Base for CO and/or Fre Detectors 0.3(0.15) SIGA-TS4 Trim Skirt(supplied with 4-inch bases) 0.1 (0.04) SIGA-TS Trim Skirt-(optional for non 4-inch bases) 0.1 (0.04) SIGA-DMP Detector Mounting Plate 3.0(1.4) SIGA-RTA Detector Removal Tool SIGA-VA Detector Cleaning Tool Page 4 of 4 DATA S H E E T E85001-1001 Not to be used for installation purposes. Issue 1.4 EDWARDS` Catalog 6 Intelligent Initiating E Fm D WA Rn D S LIFE SAFETY �c1' INCIDENT MANAGEMENT Manual Pull PULL IN GASE OF Stations RRE SIGA-270, SIGA-270P, SIGA-278 SIM-Vow Patent SIM-278 0 MEA<Fee >7150-1657: LC — 0129 52318 Overview • Break glass operation The SIGA-270 and SIGA-278 series Manual Pull Stations are part An up-front visible glass rod on the SIGA-270 discouragestampering. of EDWARDS's Signature Series system.The SIGA-270 Fre Alarm Manual Pull Stations feature our very familiar teardrop shape.They • Intelligent device with integral microprocessor are made from die-cast zinc and finished with red epoxy powder- All decisions are made at the station allowing lower com- coat paint complemented by aluminum colored stripes and mark- munication speed while substantially improving control panel ings. With positive pull-lever operation,one pull on the station response time. Less sensitive to line noise and loop wiring handle breaks the glass rod and tums in a positive alarm,ensuring properties;twisted or shielded wire is not required. protection plus fool-proof operation.Presignal models(SIGH-270P) . ADA Compliant are equipped with a general alarm(GA)keyswitch for applications Meets ADA requirements for manual pull stations. where two stage operation is required.The up-front highly visible glass rod discourages tampering,but is not required for proper • Electronic Addressing with Non-volatile memory operation. Permanently stores programmable address,serial number, type of device,and job number.Automatically updates historic EDWARDS's double action single stage SIGA-278 station is a information including hours of operation,last maintenance contemporary style manual station made from durable red colored date, number of alarms and troubles,and time and date of last lexan. To inflate an alarm,first lift the upper door marked"LIFT alp. THEN PULL HANDLE",then pull the alarm handle. a Automatic device mapping Each station transmits wiring information to the loop control- Standard Features ler regarding its location with respect to other devices on the Note.,Some features described here may not be supported by all control sys- circuit. tems.Check your control panel's Installation and Operation Guide for details. • Diagnostic LEDs • Traditional familiar appearance Status LEDs;flashing GREEN shows normal polling;flashing SIGA-270 models feature our familiar teardrop design with RED shows alarm state. simple positive pull action and sturdy die-cast metal body. • Designed for high ambient temperature operation • One stage(GA),two stage(pre-signaQ,and double action Install in ambient temperatures up to 120°F(49°C). models SIGA-270 models are available for one or two stage alarm systems.The single stage double action SIGA-278 features a rugged Lexan housing with keyed reset mechanism. Page 1 of 4DATA SHEET E85001-0279 Not to be used for installation purposes. Issue 1.11 Application Typical Wiring The operating characteristics of the fire alarm stations are deter- The fire alarm station's terminal block accepts#18 AWG(0.75mm� mined by their sub-type code or"Personality Code".NORMALLY- to#12 AWG(2.5mm�wire sizes.See Signature Loop Controller OPEN ALARM-LATCHING(Pesonality Code 1)is assigned by the catalog sheet for detailed wiring requirement specifications. factory;no user configuration is required.The device is configured for Class B IDC operation.An ALARM signal is sent to the loop Wiring Notes controller when the station's pull lever is operated.The alarm con- 0 Refer to Signature Loop Controller manual for maximum dition is latched at the station. wire distance. 2. All wiring is power limited and supervised. RE Compatibility ARVIEW of 278 Signature Series manual stations are compatible only with ED- WARDS's Signature Loop Controller. Ij co 0 0 TB2 Warnings & Cautions This device will not operate without electrical power.As fires fre- quently cause power interruption,we suggest you discuss further (Alarm/A;,e) a ® (N LED safeguards with your local fire protection specialist. O TBI O Testing & Maintenance To test(or reset)the station simply open the station and operate DATA IN DATA OUT(+J the exposed switch.The SIGA-270 series are opened with a tool; DATA IN(-) DATA OUi(-) the SIGA-278 requires the key which is supplied with that station. From Slgnahue controller Y To Next Device or Previous Device Q The station's automatic self-diagnosis identifies when it is defec- tive and causes a trouble message.The user-friendly maintenance Figure 4. Single Stage Systems program shows the current state of each Signature series device and other pertinent messages.Single devices may be deactivated temporarily,from the control panel.Availability of maintenance VIEW features is dependent on the fire alarm system used. REARof Scheduled maintenance(Regular or Selected)for proper system 270P,270Ps ® ' o 0 operation should be planned to meet the requirements of the Authority Having Jurisdiction(AHJ). Refer to current NFPA 72 and 0 TB2 ° ® ULC CAN/ULC 536 standards. alas Red LED Green LED (Alarm/Active) ® ® (Normae TBT O ° O C3 p j(DATA IN(+) DATA OUT(+) l DATA IN(-) DATA OUT(-) From Signature Controller Y To Next Device or Previous Device Q Figure 5. Two Stage Systems Page 2 of 4 DATA SHEET E85001-0279 Nol io be used for installation purposes. Issue 1.1 Installation Single-stage Signature Series fire alarm manual pull stations mount to North American 21/2 inch(64 mm)deep 1-gang boxes. Two stage presignal(270P)models require 11/2 inch(38 mm)deep 4-inch square boxes with 1-gang,t/2-inch raised covers.Openings must be angular.Rounded openings are not acceptable. Recommended box:Steel City Model 52-C-13;in Canada,use Iberville Model Cl- 52-C-49-1/2. All models include terminals are suited for#12 to#18 AWG(2.5 mm2 to 0.75 mml wire size.EDWARDS recommends that these fire alarm stations be installed according to latest recognized edition of national and local fire alarm codes. Electronic Addressing: The loop controller electronically addresses each manual station,saving valuable time during system com- missioning.Setting complicated switches or dials is not required.Each station has its own unique serial number stored in its on-board memory.The loop controller identifies each device on the loop and assigns a"soft"address to each serial number.If desired,the stations can be addressed using the SIGA-PRO Signature Program/Service Tool. Key-Lotch Compatible Electrical Box Compatible Electrical Box Cover Release Cover Release Screw o a ° ° O Bock Plate o O Back Plate 0 I ° —ToggleToggle Switch �F' o` Switch o O Qom` ' Glass Rod Glass Rod Release Lever OPEN Figure 1. SIGA-278 installation Figure 2. SIGA-270,SIGC-270F,SIGC-270B installation Cover Release 0 4--compatible Electrical Box with%-Inch ® raised covers �@, i a 1 Back Plate 0 ,i Toggle i ORAL o Switch � N Glass Rod Release Lever Do not use boxes with rounded openings. Figure 3. SIGA-270P,SIGC-270PB installation Page 3 of 4 DATA SHEET E85001-0279 Not to be used for installation purposes. Issue 1.1 Specifications SIGA-270,SIGC- SIGA-270P, Catalog Number 270F,SIGC-2708 SIGC-270PB SIGA-278 Description Single Action Single Action-Two Double Action LIFE SAFETY&INCIDENT MANAGEMENT -One Stage Stage(Presignal) -One Stage Contact us Addressing Uses 1 Module Uses 2 Module Uses 1 Module Phone: 800-655-4497(Option 4) Requirements Address Addresses Address Email: edwards fire@carrier comOperating Current Standby=250µA Standby=396µA Standby=250µA Website: edwardsfiresafety com Activated=400µA Activated=680µA Activated=400µA 8985 Town Center Pkwy Construction&Finish Diecast Zinc-Red Epoxy Lexan-Red with Bradenton,FL 34202 with aluminum markings white markings Type Code Factory Set ©2020 Carrier Operating Voltage 15.2 to 19.95 Vdc(19 Vdc nominal) All rights reserved. Operating Temperature:32OF to 120OF(0°C to 4M) Storage and Operating Storage Temperature:-4°F to 140OF(-20°C to 60°C)Humidity:0 to 93% Environment RH LED Operation On-board Green LED-Rashes when polled On-board Red LED-Flashes w hen in alarm Compatibility Use With:Signature Loop Controller Agency Listings UL,ULC(note 1),MEA,CSFM,FM Note.SIGC-27OF,SIGC-270B and SIGC-270PB are ULC listed only.Suffix"F"indicates French markings. Suffix"B"indicates Engfish/French biting ua1 markings. Ordering Information Catalog Sl,lp WL Number, Description lbs(kg) SIGA-270 One Stage Fre Alarm Station, English Markings-UL/ULC Listed SIGC-27OF One Stage Fre Alarm Station, French Markings-ULC Listed SIGC-270B One Stage Fre Alarm Station,French/English Markings-ULC Listed SIGA-270P Two Stage(Presignal)Fre Alarm Station,English Markings-UL/ULC Listed 1 (0.5) SIGC- Two Stage(Presignal)Fre Alarm Station,French/English Markings 270PB -ULC Listed SIGA-278 Double Action(One Stage)Fre Alarm Station,English Markings -UL/ULC Listed Accessories 32997 GA Key w/Tag-for pre-signal station(CANADA ONLY) 276-K2 GA Key-for pre-signal station (USA ONLY) 276-K1 Station Reset Key, Supplied with all Key Reset Stations -,0.1 (.05) 27165 12 Glass Rods-for SIGA-270 series(CANADA ONLY) 270-GLR 20 Glass Rods-for SIGA-270 series (USA ONLY) 276-GLR 20 Glass Rods-for SIGA-278 series 276B-RSB Surface Mount Box,Red-for SIGA pull stations 1 (0-6) Page 4 of 4 DATA SHEET E85001-0279 Not to be used for installation purposes. Issue 1.1 EDWARDS' Catalog Is Intelligent Input-Output E EDWAR-Hits r. LIFE SAFETY INCIDENT MANAGEMENT Input Modules SIGA—CT1 , SIGA—CT1 HT, SIGA—CT2, SIGA—MCT2 $ " • loge s1oA-c7'1/2 SIOAdY1CT2 � �L MEA r�oo-,sem: 0121 saaza Overview Standard Features The SIGA-CT1 Single Input Module,SIGH-CT1 HT High Multiple applications Temperature Single Input Module and SIGA-CT2/SIGA-MCT2 Dual Including Alarm,Alarm with delayed latching(retard)for Input Modules are intelligent analog addressable devices used to waterflow applications,Supervisory,and Monitor.The installer connect-one or two Class B normally-open Alarm,Supervisory,or selects one of four"personality codes"to be downloaded to Monitor type dry contact Initiating Device Circuits(IDC). the module through the loop controller. The actual function of these modules is determined by the • SIGA-CTI HT rated for high temperature environments "personality code"selected by the installer.This code is downloaded Suitable for attic installation and monitoring high temperature to the module from the Signature loop controller during system heat detectors. configuration. • Plug-in(UIO)or standard 1-gang mount UIO versions allow quick installation where multiple modules The input modules gather analog information from the initiating are required.The 1-gang mount version is ideal for remote devices connected to them and convert it into digital signals. locations that require a single module. The module's on-board microprocessor analyzes the signal and decides whether or not to input an alarm. • Automatic device mapping Signature modules transmit information to the loop controller The SIGA-CTI,SIGA-CTI HT and SIGA-CT2 mount to standard regarding their circuit locations with respect to other Signature North American 1-gang electrical boxes,making them ideal for devices on the wire loop. locations where only one module is required.Separate 1/0 and a Electronic addressing data loop connections are made to each module. Programmable addresses are downloaded from the loop The SIGA-CT1 HT module operates at an expanded temperature controller,a PC,or the SIGA-PRO Signature Program/Service range of 32 OF to 158 OF(0°C to 70°C)for those applications Tool.There are no switches or dials to set. requiring more extreme environmental temperature variation. • Ground fault detection by address The SIGA-MCT2 is part of the UIO family of plug-in Signature Detects ground faults right down to the device level. Series modules. It functions identically to the SIGA-CT2,but takes advantage of the modular flexibility and easy installation that characterizes all UIO modules.Two-and six-module UIO motherboards are available.All wiring connections are made to terminal blocks on the motherboard.UIO assemblies may be mounted in EDWARDS enclosures. Page 1 of 4 DATA SHEET E85001-0241 Not to be used for installation purposes. Issue 1.1 Signature Series Overview The Signature Series intelligent analog-addressable system uio Motirerboara from EDWARDS Security is an entire family of multi-sensor detectors and mounting bases,multiple-function input and output modules,network and non-network control panels,and - -- -�--� user-friendly maintenance and service tools.Analog information Plug-in(UIO) from equipment connected to Signature devices is gathered Module and converted into digital signals.An onboard microprocessor -- - --� in each Signature device measures and analyzes the signal and decides whether or not to input an alarm.The microprocessor in each Signature device provides four additional benefits—Self- cabinet oreiectricai enclosure diagnostics and History Log,Automatic Device Mapping,and Fast,Stable Communication. Self-diagnostics and History Log—Each Signature Series Electronic Addressing-The loop controller electronically device constantly runs self-checks to provide important addresses each module,saving valuable time during system maintenance information.The results of the self-check are commissioning.Setting complicated switches or dials is not automatically updated and permanently stored in its non-volatile required.Each module has its own unique serial number stored memory.This information is accessible for review any time at the in its on-board memory.The loop controller identifies each device control panel,PC,or using the SIGA-PRO Signature Program/ on the loop and assigns a"soft"address to each serial number. Service Tool. If desired,the modules can be addressed using the SIGA-PRO Automatic Device Mapping—The Signature Data Controller Signature Program/Service Tool. (SDC)learns where each device's serial number address is EDWARDS recommends that this module be installed according installed relative to other devices on the circuit.The SDC keeps a to latest recognized edition of national and local fire alarm codes. map of all Signature Series devices connected to it.The Signature Series Data Entry Program also uses the mapping feature.With Application interactive menus and graphic support,the wired circuits between each device can be examined.Layout or"as-built"drawing The duty performed by the SIGA-CT1 and SIGA-CT2/MCT2 is information showing branch wiring(T-taps),device types and their determined by their sub-type code or"Personality Code".The address are stored on disk for printing hard copy. code is selected by the installer depending upon the desired application and is downloaded from the loop controller. Installation One personality code can be assigned to the SIGA-CT1.Two SIGA-CTI,9IGA-CT1 HT and SIGA-CT2:modules mount to personality codes can be assigned to the SIGA-CT2/MCT2. North American 21/2 inch(64 mm)deep 1-gang boxes and 11/2 inch Codes 1,2,3 and 4 can be mixed on SIGA-CT2/MCT2 modules (38 mm)deep 4 inch square boxes with 1-gang covers and SIGA- only.For example,personality code 1 can be assigned to the first MP mounting plates.The terminals are suited for#12 to#18 AWG address(circuit A)and code 4 can be assigned to the second (2.5 mm2 to 0.75 mm2)wire size. address(circuit B). NORMALLY-OPEN ALARM-LATCHING(Personality Code 1) compatible electrical box -Assign to one or both circuits. Configures either circuit A or B or both for Class B normally open dry contact initiating devices such as Pull Stations,Heat Detectors,etc.An ALARM signal is sent to the loop controller when the input contact is closed.The alarm condition is latched at the module. Wall plate,white NORMALLY-OPEN ALARM-DELAYED LATCHING (1-gang) •. (Personality Code 2)-Assign to one or both circuits. Configures a either circuit A or B or both for Class B normally-open dry contact a. initiating devices such as Waterflow Alarm Switches.An ALARM signal is sent to the loop controller when the input contact is c1 closed for approximately 16 seconds.The alarm condition is latched at the module. Status LEDs NORMALLY-OPEN ACTIVE-NON-LATCHING(Personality LED viewing ports • �, Code 3)-Assign to one or both circuits.Configures either circuit p A or B or both for Class B normally-open dry contact monitoring input such as from Fans, Dampers,Doors,etc.An ACTIVE signal is sent to the loop controller when the input contact is closed.The SIGA-MCT2:mount the UIO motherboard inside a suitable ED- active condition is not latched at the module. WARDS enclosure with screws and washers provided.Plug the NORMALLY-OPEN ACTIVE-LATCHING(Personality Code SIGA-MCT2 into any available position on the motherboard and 4)-Assign to one or both circuits. Configures either circuit A or secure the module to the motherboard with the captive screws. B or both for Class B normally open dry contact monitoring input Wiring connections are made to the terminals on the motherboard such as from Supervisory and Tamper Switches.An ACTIVE signal (see wiring diagram).UIO motherboard terminals are suited for#12 is sent to the loop controller when the input contact is closed.The to#18 AWG(2.5 mm2 to 0.75 mm�wire size. active condition is latched at the module. Page 2 of 4 DATA SHEET E85001-0241 Not to be used foi iiistallation purposes. ISSue1.1 Typical Wiring Modules will accept#18 AWG(0.75mm�,#16(1.0mm�,and#14AWG(1.50mm�, and#12 AWG(2.50mm�wire sizes. Note:Sizes#16 AWG(1.0mm�and#18 AWG(0.75mm�are preferred for ease of installation.See Signature Loop Controller catalog sheet for detailed wiring requirement specifications. Initiating(Slave)Device Circuit Wire Spec cations Maximum Allowable Wire Resistance 50 ohms(25 ohms per wire)per Circuit Maximum Allowable Wire Capacitance 0.1 pF per Circuit For Design Reference: Wire Size Maximum Distance to EOLR #18 AWG(0.75 mmg #16 AWG(1.00 rnmg 4,000 ft(1,219 m) #14 AWG(1.50 mm9 #12 AWG(1.50 mm� Typical N.O.Initiating Device Typical N.O.Imitating Device J. 1 INPUT 1 INPUT 2 Z Q2 ®Style B(Gass B) TB2 TB2 8 7 UL/ULC Listed • • • 471[3 EOL UL/ULC Listed style B(Class 8) 8 7 6 e UL/ULC LLsted 4719 EOL AAA® • • • 4710 EOL Red LED Green LED (Alarm/Active) (Normae Red LED �. ® Green LED 4 3 2 1 (Alarm/Active) a 3 2 1 (Normal) TB1 TBI DATA IN(+) DATA OUT(+) {r DATA IN(-) DATA OUT(-)lY DATA IN(+) DATA OUT(+)1 1r ` DATA IN(-) DATA OUT(-)J From Signature Controller Y To Next Device Fro or SignaturePreviounctreoter To Next Device or Previous Device Q SIGA-CT1,SIGA-CT1 HT SIGA-CT2 --- NOTES um'dI om uuIW ���lyl�•3 WEOr ITi x KEX QMaximum 25 Ohm resistance per wire. 47KK 'r(, Tc"�—c..( ©Maximum#12 AWG(2.5 mm2)wire;Minimum#18 AWG(0.75 mm2). AAA ©Refer to Signature controller Installation sheet for wiring specifications. ®Maximum 10 Vdc @ 350 pA hca 5s The SIGA-UIOSR and the SIGA-1.11102R do not come with TB14. 1234III maere 6omd 6 All wiring Is supervised and power-limited. 7 These modules will not support 2-wire smoke detectors. r spa x rera N, ,mreymeewr oaK, i rmz awn tar an�r�awm,roy, Warnings & Cautions � - s� This module will not operate without electrical power.As fires fre- TMI quently cause power interruption,we suggest you discuss further safeguards with your local fire protection specialist. Compatibility SIGA-MCT2 These modules are part of EDWARDS'S Signature Series intelligent processing and control platform.They are compatible with EST3, EST3X and iO Series control panels. Page 3 of 4 DATA SHEET E85001-0241 Not to be used for installation purposes. Issue 1.1 Specifications WARDS Catalog Number SIGA-CT1HT I SIGA-CTI SIGA-CT2 I SICA-NICT2 Description Single Input Module Dual Input Module LIFE SAFETY&INCIDENT MANAGEMENT Type Code 48(factory set)Four sub-types 49(factory set)Four sub-types (personality codes)are available (personality codes)are available Contact us Address Requirements Uses One Module Address Uses Two Module Addresses Phone: 800-655-4497(Option 4) Operating Current Standby=250µ4; Standby=396pA; Email: edwards fire®carriercom Activated=400pA Activated=68Oµ4 Website: edwardsfiresafety.mm Operating Voltage 15.2 to 19.95 Vdc(19 Vdc nominal] 8985 Town Center Pkwy Construction High Impact Engineering Polymer Bradenton,FL 34202 Mounting North American 21/2 inch(64 mm)deep one-gang box- U102R/6R/6 ©2020 Carrier es and 11/2 inch (38 mm)deep 4 inch square boxes Motherboard All rights reserved. with one-gang covers and SIGH-MP mounting plates Operating Environment 32°F to 158°F 32°F to 120°F(0°C to 49°C) (0°C to 79°C) Storage Environment -4°F to 140°F(-20°C to 600C);Humidity:0 to 93%RH LED Operation On-board Green LED-Flashes when polled;On-board Red LED- Flashes when in alarm/active. Compatibility Use with Signature Loop Controller Agency Listings UL,ULC,MEA,CSFM Ordering Information Number Description Ibs kip 9 SIGA-CT1 Single Input Module—UL/ULC Listed 0.4(0.15) SIGA-CT1 HT Single Input Module High Temperature Operation UL/ULC Listed 0.4(0.15) SIGA-CT2 Dual Input Module—UL/ULC Listed 0.4(0.15) SIGA-MCT2 Dual Input Plug-in(UIO)Module —UL,ULC Listed 0.1 (0.05) Related Equipment 27193-11 Surface Mount Box-Red,1-gang 1.0(0.6) 27193-16 Surface Mount Box-White,1-gang 1.0(0.6) SIGA-U102R Universal Input-Output Module Board w/Riser Inputs 0.32(0.15) —Two Module Positions Universal Input-Output Module Board w/Riser Inputs SIGA U106R _Six Module Positions 0.62(0.28) SIGA-U106 Universal Input-Output Module Board —Six Module Positions 0.56(0.25) MFC-A Multifunction Fire Cabinet—Red,supports Signature Module 7,0(3.1) Mounting Plates SIGA-MB4 Transponder Mounting Bracket(allows for mounting 0.4(0.15) two 1-gang modules in a 2-gang box) SIGA-MP1 Signature Module Mounting Plate,1 footprint 1.5(0.70) SIGA-MP2 Signature Module Mounting Plate,1/2 footprint 0.5(0.23) SIGA-MP2L Signature Module Mounting Plate,1/2 extended footprint 1.02(0.46) Page 4of4 DATA SHEET E85001-0241 � Not to be used for installation purposes. Issue 1.1