Loading...
EA178738 - Building - Single Fam - Issued Date 11/28/2022PERMIT City of Eagan • , , , Permit Type: Building 3830 Pilot Knob Rd Eagan, MN 55122 •--- %•EAGAN Permit Number: EA178738 (651) 675-5675 ^� $3,018.75 0801.4085 City SAC (01 Unit) www.cityofeagan.com 9376.4681 Plan Review * E R 1 7 8 7 3 8* Radio Read Unit (Domestic) $205.00 6101.4509 Date Issued: 11/28/2022 Site Address: 1413 Vince Tr $213.50 9001.2195 Surcharge -Fixed Lot: 1 Block: 1 Addition: Kennerick 3rd Treatment Plant - Residential $1,065.50 PID: 10-41502-01-010 Water Permit $64.00 6101.4507 Water Supply & Storage Use: 6101.4680 * 10-4 1502-0 1 —0 10* Description: Tree Preservation Performance Guarantee $5,000.00 9111.2257 Sub Type: Single Fam Construction Type: V -B Work Type: New Description: Census Code: 101- Single Family Houses Occupancy: IRC -1 Zoning: R-1 Square Feet: 0 Comments: Improvements to the home may require smoke detectors in all bedrooms. Carbon monoxide detectors are required within 10 feet of all sleeping room openings in residential homes (Minnesota State Building Code). Fee Summary: 3/4" Meter $300.00 6101.4509 BL - Base Fee Valuation: 426,998.00 $3,018.75 0801.4085 City SAC (01 Unit) $131.50 9376.4681 Plan Review $1,962.19 0720.4222 Radio Read Unit (Domestic) $205.00 6101.4509 Sewer Permit $64.00 6201.4532 Surcharge - Based on Valuation $213.50 9001.2195 Surcharge -Fixed $1.00 9001.2195 Treatment Plant - Residential $1,065.50 6101.4685 Water Permit $64.00 6101.4507 Water Supply & Storage $1,715.10 6101.4680 SAC (1 unit) - Single Family House $2,485.00 9220.2275 Tree Preservation Performance Guarantee $5,000.00 9111.2257 Contractor: Total: $16,225.54 Owner: Eternity Homes LLC 425 Third St Farmington MN 55024 Applicant - This permit shall be null and void if work does not start within 180 days of issuance, or if work is suspended for 180 days or more after started. I hereby acknowledge that I have read this application and state that the information is correct and agree to comply with all applicable State of Minnesota Statutes and City of Eagan Ordinances. Applicant/Permitee: Signature ssued B . Signature / f L- Iq K -f3 I prem s, sw---------, l�-4Z r-------- 0 0 For Office Use o��e® ®�e�®m � (I, 9"�• � / i Permit#; 13:9 J� 6 � Permit Fee:A (A0 jwftA VAUECEIVE Date Received:3830 PILOT KNOB ROAD 1 EAGAN, MN 55122-1810G 3 , 2 (651) 675-5675 l FAX: (651) 675-5694 Staff: buildinginscections .ciNofeaaan.com I-----------------'' BY: aa 2021 RESIDENTIAL BUILDING PERMIT APPLICATION Date: g Jl Site Address: 1413 Vince Trail Unit #: Name: Eternity Homes LLC Phone: 651-460-3043 Resldent/ 425.3rd St / Farmington / 55024 O% ner Address / City / Zip: Applicant Is: V( Owner V/ Contractor owner Email: coraleternityhomeslic@gmail.com Type of Work Description of work: New Construction Construction Cost: $400,000 Multi -Family Building: (Yes /No X ) Company: Eternity Homes LLC Contact: Coral Ozmun Contractor Address: 425 3rd St City: Farmington State: MN Zip: 55024 Phone: 651-460-30,ii Email: coraleternityhomesllc@gmail.com License #: BC638704 Lead Certificate #: If the project is exempt from lead certification, please explain why: COMPLETE THIS AREA ONLY IF CONSTRUCTING A NEW BUILDING In the last 12 months, has the City of Eagan Issued a permit for a similar plan based on a master plan? Yes (X No If yes, date and address of master plan: Licensed Plumber: Slewa•YA- C kUm6i u, t h Phone: -1 W5— 412-44 X33 Mechanical Contractor: t IY115ko 4 e "I V\G4 Phone: q J5,z -0 q-4-6L)O5 Sewer & Water Contractor: i0 • Phone: W 5 l ` q oy - i ` b 'Fire Suppression Contractor. Phone: NOTF:'Plahs and,supporting documents that you submit are considered to be public Information. Portions of the Information maybe classified as nqn- ubllc !f you grovide specific reasons that would It the qLW to conclude that thqX are trade secrets. You may subscribe to receive an electronic notification from the City of proposed ordinances by signing up for an email update on the City's website at wuvw•-cttvofeaaan.com/subscribe. CALL BEFORE YOU DIG. Contact Gopher State One Call at (651) 454-0002 or www.aooherstateonecall.ora for protection against underground utility damage. Contact Gopher State One Call 48 hours before you intend to dig to receive locates of underground utilities. I herebyacknowledge that this Information is complete and accurate; that the work will be In conformance with the ordinances and codes of the City of Eagan; that I understand this Is not a permit, but only an application for a permit, and work is not to start without a permit; that the work will be In accordance with the approved plan in the case of work which requires a review and approval of plans. XCoral Ozmun x &,,�� Applicant's Printed Name Applicant's Signature FOR OFFICE USE ONLY Site Address: i 9(3 J i h c -p- � Permit #: g �3 SUB TYPES Foundation _ Fireplace _ Porch (3 -Season) _ Miscellaneous Single Family _ Garage _ Porch (4 -Season) _ Accessory Building Multi — Deck _ Porch (Screen/Gazebo/Pergola) 01 of _ Plex _ Lower Level — Pool WORK TYPES New _ Repair _ Siding _ Retaining Wall Addition Fire Repair — Reroof _ Move Building _ _ Alteration _ Water Damage _ Windows _ Demolish Building* — Replace _ Egress Window _ Solar *Demolition of entire building - give PCA handout to applicant DESCRIPTION Calculated Valuation 'ft/pid"s' 14o Occupancy 1QG-1 MCES System X Plan Review Code Edition 04"Cl-"zoo SAC Units :�.. (25%_ 100 Zoning City Water Census Code Stories Booster Pump # of Units Square Feet PRV # of Buildings Length Fire Suppression Required Type of Construction �_ Width REQUIRED INSPECTIONS Footings (New Building) Meter Size: Footings (Deck) Final / C.O. Required Footings (Addition) Final / No C.O. Required Foundation= =Foundation Before Backfill HVAC _ Service Test Gas Line Air Test _ Hood Roof: K Ice & Water k Final Pool: _Footings Air/Gas Tests _Final X Framing 30 Minutes X- 1 Hour Drain Tile Fireplace: _Rough In Air Test _Final jc Siding: _Stucco Lath ,x Stone Lath _Brick _ EFIS Insulation Windows Sheathing Retaining Wall: _ Footings _ Backfill _ Final Sheetrock Radon Control Fire Walls Fire Suppression: _Rough In _Final Braced Walls Erosion Control Shower Pan Other: Reviewed By: , Building Inspector RESIDENTIAL FEES:35 fig• GGtF!►�y4L�d - Z3 � X �� • � It - S Calculated Valuation . shed iflb9� 95.13 loz, 33.3* Base Fee 853k 40. + = 33, lobi . 53 Plan Review 1301 X 9.0. 73 a /25 310.59 State Surcharge i MCES SAC 2 "d FYoO r 1 409J x 90. 73 & 61 g79 H� City SAC Utility Connection Charge Y2(60 998, ,qD S&W Permit & Surcharge Treatment Plant Radio Read Other: Copies: TOTAL $ 0.00 � I Eternity Homes LLC 651-460-3043 EAGAN 425 3rd St / Farmington / 55024 3830 PILOT KNOB ROAD I EAGAN, MN 55122-1810 (651) 675-53001 waterres0citvofeaaan.com p ------------------------- For Office Use I I I I Stormwater Management Permit#: � 4 1 I I Building Permit M. 1 I I I I Escrow Deposit: I I I I I I Staff: 1 I I L-------------------------, STORMWATER MANAGEMENT PERMIT Date: ��' 2 Site Address: 1413 Vince Trail Description of Project: New Construction Area of Land Being Disturbed: 2,707 Start Date: Completion Date: ❑ Please submit a Land Disturbance and Stormwater Pollution Prevention Plan with this application. Eternity Homes LLC 651-460-3043 Name: Phone: 425 3rd St / Farmington / 55024 Property Owner Address/City/Zip: Coral draftingeternityhomesllc@gmail.com Contact: Email: Applicant is: 1( Owner V( Contractor Eternity Homes LLC BC638704 Name: License# 425 3rd St Farmington Contractor Address: City: MN 55024 651-460-3043 State: Zip..Phone: Coral draftingeternityhomesllc@gmail.com conte Email: Erosion and Sediment Control Performance Security The City requires an escrow deposit to secure performance of erosion and sediment control (ESC) requirements, Including proper Installation and maintenance. The security shall pay for any City costs or expenses to bring the site into compliance with the stormwater management permit, including any engineering, legal, or administrative expenses; inspections; and necessary work by City contractor(s). The City may extract from the security escrow. The escrow deposit will be released only upon inspection and written notice of conformance by the City. The following escrow deposits Include two (2) required City Inspections, Initial and final. Existing Single-Famlly Residential Lot (addition, demolition, pool, retaining wall, etc.) $1,3001lot New Single -Family Construction $3,800/lot Multi -Family or Commercial Construction (new, addition, demolition) $6,500/acre* *Maximum of $12,000 Erosion and Sediment Control Reinspection Fee (for as needed City reinspection after the two (2) Included) $85/trip Security Amount: 3900 The applicant assumes all responsibilities for installation and maintenance of pollution prevention practices on this site. Any violations of City Code identified by the City shall be addressed within 48 -hours of service of the notification. The applicant understands that failure to maintain pollution prevention practices within the time allotted by the City notification, will result in enforcement action to correct site deficiencies that are in violation of Sec. 4.34. The issuance of this permit constitutes a right -of -entry of the City or its contractors to enter upon the construction site for the purpose of completing ordinance enforcement and/or completing corrective work. I hereby acknowledge that this information is complete and accurate; that the work will be in conformance with the ordinances and codes of the City of Eagan; that I understand this is not a permit, but only an application for a permit, and work is not to start without a permit; that the work will be in accordance with the approved plan in the case of work which requires a review and approval of plans. The undersigned accepts full responsibility for compliance with the Stormwater Management Ordinance of the City of Eagan and agrees to comply with the Stormwater Pollution Prevention Plan or equivalent in full. X Coral Ozmun Applicant's Printed Name X0- &44&�= r App cant's Signatur Performance Security Release The following information will determine to whom the escrow deposit will be returned. Security will be returned in the form of a check. Name: Eternity Homes LLC Address / City / Zip: 425 3rd St / Farmington / 55024 Phone: 651-460-3043 Email: invoicingeternityhomesllc@gmail.com Amount: $3,900 Permit Number: FOR OFFICE USE ONLY SUB TYPE Stormwater Management Permit DESCRIPTION Addition _-Demolition New Retaining Wall REQUIRED INSPECTIONS Initial Inspection Final Inspection SECURITY WORK TYPE Apartments Commerclal/industrlal Multi Famlly Public Facility Single Family Erosion and Sediment Control Deposit (6501.2257) Pool Other: $3,900 Other: Total: $3,900 10/27/2022 Reviewed By: ater Resources Date: City Inspection Dept. Copy EAGAN City Forester Copy ApplicantlBuilder Copy INDIVIDUAL RESIDENTIAL LOT TREE PRESERVATION PLAN SUMMARY CITY OF EAGAN FORESTRY©MS/ON 651-675-5300 (BUILDER, PLEASE READ ATTACHMENTS) Development Kennerick 3rd Addition Lot Number 1 Block Number 1 Address 1413 Vince Trail Builder Eternity Homes, LLC Phone Number: Contact: Tree Protection Reauirementsi 651-460-3043 Coral X Tree Protectlon Fencing to beinstalIed on Site _(O_range Poly: Fence) Oak Tree Pruning (Immediately seal wounds during April 1 to July 31) Therapeutic Pruning Required Retaining Wall To Be Installed Other: (Replacement Trees! X - Not Required Cash dedication in lieu ofplanting As Follows:@ moi_ / Attachments: X Yes (Refer to attachi d No 8A171 RESTRY DIVISION GAM 'v ry REVIEWED Additional Notes: DATE to[ -z12 -z-- ,. TREE PRESERVATION PLAN - 413 Vince Trail.dom r`, �ta �r9 �..,. �r r� .., ., ., " ,� - G t � �^ ee .::haa-twT.a-.+��.4c'Y"T.:c.Z.u9:_'-.: .. erT,...t�sa 4r,-.:r��'gg��_.e3+:u', ... r. e) �3 $ W J ... xa., z-.�-�: s.v^'�^-aRvwArx®va; e�iPlhoaw... - _.. ia:R Jrta�plam'.w .. m�:mca. . .. -.- _�. ..w�.-..rK..cue+oma!cr.,.a�.w9.tv.C.'.s8zsias•.�e...e�.�.u�+c. n �: .,.. .,.. �..a—,.uw.e�Fav^,�L. s. e.. .. .. :-: ...-._... 1413 Vince Trail AI EAGAN I Lakes Storm Basin Wetlands Sections Numbers Aerial Street Names 1 in=94ft Mull aria�, Gis VCtober 7, 202. ADDRESS: 1413 VINCE TRAIL N07E ALL BWLVBVG DIMENSIONS ARE SHOWN TO OUTSIDE OF FOUN247701V WALL LOT AREA - 16,309 SO. FT, HOUSE AREA - 2,142 SO. FT. SETBACK INFORMATION: FRONT - 30' SIDE YARD -10' (HOUSE) SIDE YARD - 5' (GARAGE) REAR YARD =15' (HOUSE) REAR YARD - 5' (SHED) 1°=20' TREE TABLE TAGJ SPECIES Of COTTONWOOD, EASTERN 02 COTTONWOOD, E457MV 03 COTTONWOOD, EAMM 04 BIRM, PAPER 05 MAPLE; SILVER 06 ASH, GREEN 07 CRABAPPLE 08 CRABAPPLE 09 CRABAPPLE fO MULBERRY, RED 11 MULBERRY, RED CERTIFICATE OF SURVEY FOR ETERNITY HOMES LLC 8� VINCE TRAIL N89°55'38°W 4.00 DMME7ER CONDIRON 35' GOOD 28' GOOD 28GOOD 14' FAW 28' GOOD 24' GOOD 06' FAR 09' FAR 06 FAR 12' GOOD 12' FAW N07E TREE TABLE INFORMATION WAS TAKEN FROM THE TIME PRESERVATION PLAN PREPARED BY ROMER FORESTRY CD UUL77HO WED 1-20-21 ® DENOTES MAILBOX ED ,,p j, o — I t unLrry 9'& , O DENOTES IRON PIPE MONUMENT SET I ��� 9" `o'91I 91 a 1 —11' DENOTES FOUND D ON PIPE MONUMENt -SDs / Stas o1 1i1 .7 1 N89°58'20°VH 77.00E—� 9I s 91 �— DENOTES PROPOSED DRAINAGE DIRECTION 9 NOTE• ADD 3 EXTRA STEPS BETWEEN THE HOUSE AND 0 DENOTES SERVICE LOCATION GARAGE — 2.2 EI DENOTES WOOD HUB PROPOSED TOP OF WALL ELEV. - 905,2 000.0 DENOTES EXISTING ELEVATION PROPOSED GARAGE FLOOR EL& - 903.0 ® DENOTES PROPOSED ELEVATION PROPOSED BASEMEN FLOOR ELEV. = 897.5 DENOTES EXISTING CONTOUR PROPERTY DESCRIPTION DENOTES DECIDUOUS TREE LOT 1, BLOCK 1, KENNERICK THIRD ADDITION, DENOTES EVERGREEN TREE CITY OF PAGAN, DAKOTA COUNTY, MINNESOTA. Bohlen I HEREBY CERTIFY THAT THIS SURVEY WAS PREPARED I3Y ME OR DENOTES BITUMINOUS SURFACE Surveying & Associates UNDER MY DIRECT SUPERVISION AND THAT I AM A DULY LICENSED LAND SURVEYOR UNDER THE LAWS OF THE STATE OF MINNESOTA DENOTES CONCRETE SURFACE 31432 FaUge Av 1682 r22r Rd E. N=V&K MN Man 6—m" n N es9w TIw1'Iloe B A DATE 8-31-2022 S CK" l¢cna, DENOTES GRAVEL SURFACE vn�ac6w8 e4sna6 FF -(952)89989212 Fec lam) J. S SO. URVEYOR - MINNESOTA UCTHOMAS EENSSEE NSD F:1Pmjcm\Eegn\km crick-rind-additionTdwg\LIBI-=-8-24-22.dwg 04/2022 7:18:12AMCDT TREE PRESERVATION PLAN REVIEW — INDIVIDUAL LOT "— EAGAN Date Building Permit Application Received 8/31/22 Development Kennerick 3rd Addition Lot 1 Block 1 Site Address 1413 Vince Trail Builder Eternity Homes, LLC Contact Coral Telephone 651-460-3043 E-mail coraletemityhomesllc _gmail.com Property/Lot Owner Nam Telephone E-mail Office Plan Review -Date. 9/12/22 Notes Tree inventory was submitted with the certificate of survey with this application. Site contains 11 sianificant trees. less 1 Ash. Of the ten significant trees, seven are proposed for removal. The removal of significant trees over the allowable removal limit calculates to required mitigation of 10 Category B trees or cash equivalent of $5,000.00. Request for decision sent 9/12 Response received 10/3 Tree Preservation Data Total Significant Woodland Area Total Significant Trees Woodland To Be Removed Trees To Be Removed Allowable Woodland Removal (20%) Allowable Tree Removal (20%) Required Mitigation YES (or) NO Original Plan sq. ft 10 sq. ft 7 sq. ft 2 Revised Plan Calculated Mitigation Amounts Original Plan - Category A 10 Category B Category C Revised Plan - Category A Category.B Category C ft sq. ft sq. ft Site Inspection —Date 9/12/22 Notes Home Location not staked. Ash tree is in fair condition but is untreated and should be removed. GAFores"VreePreservation\Tree Preservation Plan Review - Individual LoLdoa Original Tree Preservation Plan Approved— Date 10/7/22 By Forwarded to Inspections —Date 10/7/22 By Discussion/Meetings with Builder/Owner - Coral/Eternity 10/3 Notes Applicant has indicated that the buy will pay the dedication. Completed permit review will be forwarded today (10/7) Revised Tree Preservation Plan Approved — Date By, Forwarded to Inspections — Date By Additional Field Inspections Date Notes GAFores"\TreePreservatlon\Tree Preservation Plan Review - Individual Lad= Date Notes Date Notes Date Notes GAFores"\TreePreservatlon\Tree Preservation Plan Review - Individual Lad= KENNERICK 3rd ADDITION LOT 1 BLOCK 1 -TREE PRESERVATION CALCULATION WORKSHEET 9/6/2022 Property Address: 1413 Vince Trail Development Type = Single Family Residential Existing Allowable Actual Actual Required Cash Trees Removal Removal reserved Mitt ag tion Eaulvalent 10 Trees 20.0% 7 Trees 3 Trees 5 B trees $2,000 2.0 Trees 70.0% 30.09/o (Applicant to mitgate: 5 Trees) Category of Tree Number of Mitigation Total Total To Be Removed Trees Removed Per Tree (Bl Mitigation (B) Mitinatlon (A1 Specimen Trees 0 6 0 0 Hdwd Deciduous 21-30" 0 4 0 0 Soft Deciduos >24" 0 4 0 0 Conifer > 24' (12" dbh) 0 4 0 0 Hdwd Deciduos 6-20" 2 2 4 2 Soft Deciduous 12-24" 3 2 6 3 Conifer 12-24' (<12' dbh) 0 2 Q 0 5 Cat A trees total = 5 TREE MITIGATION = 10 Category 8 Trees QUA ti-riTv nF ftAITiC;AT19N TREES PROVIDED= 0 Category B Trees Balance of mitigation trees to be fumied = 'rO- Catego Trees _- _ y Cash equivalent due to fulfill tree mitigation = - $5,000 ADDRESS: 1413 VINCE TRAIL EAGAN FORESTRY DIVISION REVIEWED BY. A. SCHNAIBLE DATE: LOT AREA = 16,309 SO. FT. HOUSE AREA = 2,142 SO. FT. SETBACK INFORMATION: FRONT = 30' SIDE YARD =10' (HOUSE) SIDE YARD = 5' (GARAGE) REAR YARD =15' (HOUSE) REAR YARD = 5' (SHED) 1"=20' TREE TABLE N89056389W 4.00 TAG# SPECIES. DIAMETER STATUS 04 0 35— Remove 02 , z'8-1 Remove 03 , agE Remove 04 BARGEE --PAPER W Remove 05 bAP&&, S& 28` Remove 06 CASH. GREED 24� Excluded 07 0!r Remove 08 Remove 99 CRA6IAP Save 10VdULBERRY, R 2 Save 'VIBE RY"'-RE Save NOTE TREE TABLE INFORMATION WAS TAKEN FROM THE TREE PRESERVA770M PLAN PREPARED BY REHDER FORESTRY CONSULTING DATED 1-20-21 ® DENOTES MAILBOX O DENOTES IRON PIPE MONUMENT SET 0 DENOTES FOUND IRON PIPE MONUMENT DENOTES PROPOSED DRAINAGE DIRECTION DENOTES SERVICE LOCATION El DENOTES WOOD HUB 000.0 DENOTES EXISTING ELEVATION ® DENOTES PROPOSED ELEVATION dap— DENOTES EXISTING CONTOUR DENOTES DECIDUOUS TREE DENOTES EVERGREEN TREE DENOTES BITUMINOUS SURFACE DENOTES CONCRETE SURFACE DENOTES GRAVEL SURFACE IM -v 9W.7 Tree Preservation Plan FOR ETERNITY HOMES LLC CENTERLINE CE TRAIL N89°56'20"W NOTE. ADD 3 EXTRA STEPS BETWEEN 7HE HOUSE AND GARAGE = 2.2 PROPOSED TOP OF WAIL ELEV. — 905.2 PROPOSED GARAGE FLOOR ELM = 903.0 PROPOSED BASEMENT FLOOR ELE14 = 897.5 PROPERTY ' DESCRIPTION LOT 1, BLOCK 1, KENNERICK THIRD ADDITION, CITY OF EAGAN, DAKOTA COUNTY, M1NNESOTA. Bohlen I HEREBY CERTIFY THAT THIS SURVEY WAS PREPARED BY ME OR Surveying & Associates UNDER MY DIRECT SUPERVISION AND THAT IAM A DULY LICENSED LAND SURVEYOR UNDER THE LAWS OF THE STATE OF MINNESOTA. 31432 Foliage AwwW 1882 Cuff Road E. NWWWd, MN 55M Sumavft. MN 65337 DATE: e-31-2022 T6r4d -1 ff''1R.ana. FhM. (C4>7) 045-7M BA PhM. (ON) 895912 THOMAS J. O'MEARA, LAND SURVEYOR FMC (DR) 699269 MINNESOTA LICENSE NO. 46167 F-WtgeetalEagan%ennerick third-addition\dwg\LIB1-cert-8 2422.dwg 8/24/2022 7:18:12 AM CDT -0 MUMNSVILLE Heating & Air Conditioning, Inc. Table 501.4.1 Procedure to Determine Makeup Air Quantity for Exhaust Appliances in Dwelling Units A. Use this column if there are other than fan -assisted or atmospherically venter gas or oil appliances or if there are no combustion appliances. B. Use this column if there is one fan -assisted appliance per venting system. Other atmospherically vented appliances may also be Included. C. Use this column if there is one atmospherically vented (other than fan -assisted) gas or oil appliance per venting system or one solid fuel appliance. D. Use this column If there are multiple atmospherically vented gas or oil appliances using a common vent or if there are atmospherically vented gas or all MULTIPLE ONE OR MULTIPLE ONE OR MULTIPLE ONE APPLIANCES THAT POWER VENT OR FAN -ASSISTED ATMOSPHERICALLY ARE DIRECT VENT APPLIANCES AND VENTED GAS OR OIL ATMOSPHERICALLY APPLIANCES OR NO POWER VENT OR APPLIANCE OR ONE VENTED GAS OR OIL COMBUSTION DIRECT VENT SOLID FUEL APPLIANCES OR SOLID APPLIANCESA APPLIANCESa APPUANCEc FUEL APPLIANCESo 1. Use Appropriate Column to Estimate House Infiltration a) pressure factor (cfm/sf) 0.15 0.09 0.06 0.03 b) conditioned floor 4344 area (sf) (including unfinished basements) Estimated House 651.6 Infiltration (cfm): [lax 1b] 2. Exhaust Capacity a) Clothes dryer 135 135 135 135 b) 80% of largest 64 exhaust rating (cfm) (not applicable if recirculating system or if powered makeup air is electrically interlocked and matched to exhaust c) 80% of next 64 largest exhaust rating (cfm): (not applicable if recirculating system or if powered makeup air is electric ly Interlocked and matched to exhaust Total Exhaust Capacity 263 (cfm): [2a+2b+2c] 3. Makeup Air Require ent 547)Total Exhaust 263 Capacity (from above) b) Estimated 651.6 House Infiltration (from above) Makeup Air -388.6 Quality (cfm): [3a -3b] (if value is negative, no makeup air is needed 4. For Makeup Air opening Sizing, refer to Table 501.4.2 A. Use this column if there are other than fan -assisted or atmospherically venter gas or oil appliances or if there are no combustion appliances. B. Use this column if there is one fan -assisted appliance per venting system. Other atmospherically vented appliances may also be Included. C. Use this column if there is one atmospherically vented (other than fan -assisted) gas or oil appliance per venting system or one solid fuel appliance. D. Use this column If there are multiple atmospherically vented gas or oil appliances using a common vent or if there are atmospherically vented gas or all MURINSVILLE Heating & Air Conditioning, Inc. Table 501.4.2 Makeup Air Opening Sizing Table for New and Existing Dwelling Units A. Use this column Ifthere are other than fan -assisted or atmospherically vented gas or all appliances or Ifthere are no combustion appliances. B. Use this column Ifthere is one fan -assisted appliance per venting system. Other than atmospherically vented appliances may also be Included. C. Use this column if there is on atmospherically vented (other than fan -assisted) gas or oil appliance per venting system or one solid fuel appliance. D. Use this column Ifthere is multiple atmospherically vented gas or oil appliances using a common vent or I there are atmospherically vented gas or oil appliances and solid fuel appliances. E. An equivalent length of 100 feet of round smooth metal dud is assumed. Subtract 40 feet for the exterior hood and ten feet for each 90 -degree elbow to determine the remaining length of straight dud allowable. F. if flexible dud is used, increase the dud diameter b one inch. Flexible dud shall be stretched with minimal sags. G. Barometric dampers are prohibited in passive makeup air openings when any atmospherically vented appliance Is installed. H. Powered makeup air shall be electrically interlocked with the largest exhaust system. MULTIPLE ONE OR MULTIPLE ONE OR MULTIPLE ONE APPLIANCES THAT POWER VENT OR FAN -ASSISTED ATMOSPHERICALLY ARE DIRECT VENT APPLIANCES AND VENTED GAS OR OIL ATMOSPHERICALLY PASSIVE MAKEUP APPLIANCES OR NO POWER VENT OR APPLIANES OR ONE VENTED GAS OR OIL AIR OPENING DUCT TYPE OF OPENING COMBUSTION DIRECT VENT SOLID FUEL APPLIANCES OR DIAMETERE F,G OR SYSTEM APPLIANCESA APPUANCESB APPLIANCEc SOLID FUEL APPLIANCESD WITI) WITI) (dm) (Cfm) (inches) Passive opening 1-36 1-22 1-15 1-9 3 Passive opening 37-66 23-41 16-28 10-17 4 Passive opening 67-109 42-66 29-46 18-28 5 Passive opening 110-163 67-100 47-69 29-42 6 Passive opening 164-232 101-143 70-99 43-61 7 Passive opening 233-317 144-195 100-135 62-83 8 Passive opening w/motorized 318-419 196-258 136-179 84-110 9 damper Passive opening w/motorized 420-539 259-332 180-230 111-142 10 damper Passive opening w/motorized 540-679 333-419 231-290 143-179 11 damper Powered makeup airH >679 >419 >290 >179 NA A. Use this column Ifthere are other than fan -assisted or atmospherically vented gas or all appliances or Ifthere are no combustion appliances. B. Use this column Ifthere is one fan -assisted appliance per venting system. Other than atmospherically vented appliances may also be Included. C. Use this column if there is on atmospherically vented (other than fan -assisted) gas or oil appliance per venting system or one solid fuel appliance. D. Use this column Ifthere is multiple atmospherically vented gas or oil appliances using a common vent or I there are atmospherically vented gas or oil appliances and solid fuel appliances. E. An equivalent length of 100 feet of round smooth metal dud is assumed. Subtract 40 feet for the exterior hood and ten feet for each 90 -degree elbow to determine the remaining length of straight dud allowable. F. if flexible dud is used, increase the dud diameter b one inch. Flexible dud shall be stretched with minimal sags. G. Barometric dampers are prohibited in passive makeup air openings when any atmospherically vented appliance Is installed. H. Powered makeup air shall be electrically interlocked with the largest exhaust system. ADDRESS: 1413 VMCE TRAIL REVIEWED FOR CODE COMPLIANCE3:1 MAX. SLOPES OR RETAINING WALL REQUIRED EAGAN INSTALL PERIMETER Dave W��2P a7n CONTROL 0910912022 127:12 NOTE. ALL BU/LD/NG DIMENSIONS ARE SHOWN TO OUTS/DE OF FOUNDATION WALL LOT AREA = 16,309 SO. Fr HOUSE AREA = 2,142 SO. FT. SETBACK INFORMATION: FRONT = 30' SIDE YARD = 10' (HOUSE) SIDE YARD = 5' (GARAGE) REAR YARD = 15' (HOUSE) REAR YARD = 5' (SHED) Isk 1 891.8-- ?IrN 35�Q( BENCHMARK: 44T -A-$°4310 TNH=894.GO 894.4 ti d7 rn W N N d• O 0 O O z CERTIFICATE OF SURVEY FOR ETERNITY HOMES LLC CENTERLINE VINCE TRAIL / 1 n o»., rURLj STOP �l l L-- 897 - - Ln N Q'. 896.2 98.6 902.9 im-x-X903.4 X 899.5 / 9 7 to K LINE _ 99 G� RI x 900.E 9�4.o 9 / I ® a of I \ I I PROP05ED1 2 RIVEW I 5.91 i 9.G ,•� x 903.1 9X.1 .04'8 I Tk I JR4 03 -'- i N I i 21.0 6z 0 20.0 - IX.O a 903.X POR;hi 906.2 0 9046 9 l x� � ' 12.0 0 7 GARAGE, o� m 8 O TE: ADD 3 EXTRA / p LL, 5 ( �� TEP5 BETWEEN Tl�k-� i o 9 / HOUSE AND GA GE J / N O ' 104.4 e 5.6 ti O N89°55'38"W 4.00 TREE TABLE DENOTES MAILBOX O DENOTES IRON PIPE MONUMENT SET TA G# SPECIES. DIAMETER CONDITION DENOTES PROPOSED DRAINAGE DIRECTION 01 COTTONWOOD, EASTERN 35' GOOD 000.0 02 COTTONWOOD, EASTERN 28' GOOD DENOTES EXISTING CONTOUR 03 COTTONWOOD, EASTERN 28' GOOD 04 BIRCH, PAPER 14' FAIR 05 MAPLE, SILVER 28' GOOD 06 ASH, GREEN 24' GOOD 00 07 CRABAPPLE 06' FAIR 08 CRABAPPLE 09' FAIR p 09 CRABAPPLE 06' FAIR V- 10 MULBERRY, RED 12' GOOD LU 11 MULBERRY, RED 12' FAIR C0 N O NOTE: TREE TABLE INFORMATION WAS TAKEN FROM 0 THE TREE PRESERVATION PLAN PREPARED BY REHOER FORESTRY CONSULTING DATED 1-20-21 z © DENOTES MAILBOX O DENOTES IRON PIPE MONUMENT SET 0 DENOTES FOUND IRON PIPE MONUMENT �- DENOTES PROPOSED DRAINAGE DIRECTION 7 DENOTES SERVICE LOCATION O DENOTES WOOD HUB 000.0 DENOTES EXISTING ELEVATION 0 0 DENOTES PROPOSED ELEVATION boo-- DENOTES EXISTING CONTOUR DENOTES DECIDUOUS TREE DENOTES EVERGREEN TREE DENOTES BITUMINOUS SURFACE DENOTES CONCRETE SURFACE DENOTES GRAVEL SURFACE 908.3 I 3x cs z _N y ' f 908.7 co J m x 904.7 x 90 .8 O p PROPOSEIR 8 p' 0 2-STOR 5 '6 1 m FB/FL c 19.0 14.0 W/w 0 0 OF wN✓ ` (9 13.0 161, 906.1 I 9v / fCUD s MD 904 I � I PROPOSED RETAINING i� WALL 905.2 'x a ! O 0 LU M co O Z X 907.2 91 1 J 5 I 08.7 I 9 o`b Q I�I 1 909.8 ' L eo' 1905 00 9 I 00 9 2 ® 908.2 I `�ps _ 909 X9 .4 I yt 911.0 � ;'SOT 1 o; BLOCS 4- i , 'I T 1" 51 z i x 911.E x911.3 I / /x 913.1 "I 11�1 914.0, x 913.4 E 5 �I 7{910.9 ,A /I 5 L / 912.0 I 9 9�03�, m T g 111 DRAi'NAGE 4 UTILITY EASE NT 'n 91T 0 1 -,i . N89°56'20"W 77.00 9 NOTE. ADD 3 EXTRA STEPS BETWEEN THE HOUSE AND GARAGE = 2.2 PROPOSED TOP OF WALL ELEK = 905.2 PROPOSED GARAGE FLOOR ELEV. = 903.0 PROPOSED BASEMENT FLOOR ELEV. = 897.5 PROPERTY DESCRIPTION LOT 1, BLOCK 1, KENNERICK THIRD ADDITION, CITY OF EAGAN, DAKOTA COUNTY, MINNESOTA. Bohlen I HEREBY CERTIFY THAT THIS SURVEY WAS PREPARED BY ME OR UNDER MY DIRECT SUPERVISION AND THAT I AM A DULY LICENSED Surveying &Associates LAND SURVEYOR UNDER THE LAWS OF THE STATE OF MINNESOTA. 31432 Foliage Avenue 1682 Cliff Road E. Northfield, MN 55057 Burnsville, MN 55337 DATE: 8-31-2022 Thmd T OlRQW . Phone: (507) 645-7766 A Phone: (952) 895-9212 THOMAS J. O'MEARA, LAND SURVEYOR tomeara@boNensurveying.com Fax: (952) 895-9259 MINNESOTA LICENSE NO. 46167 F:\Projects\Eagan\kennerick-third-addition\dwg\L1B1-cert-8-24-22.dwg 8/24/2022 7:18:12 AM CDT C:\ ...\NJJ The Cape Cod w sport ct W.rhv Thursday. October 20. 2022. 11:41 PM Rhvac Rps 8 Light Commercial hIIVAC Loads ©ite Softwar$ De Inr; rtvelopme, B�msville'lieating 8 AIC tnc The Cape Cod With SpoCt j Bumsville MN 55337 h '2 Project Report I lThe Project Title: Cape Cod With Sport Ct Designed By: Alan Dobson Project Date: Thursday, October 20, 2022 Project Comment: Client Name: Eternity Homes Company Name: Burnsville Heating & A/C Inc. Company Representative: Alan Dobson Company Address: 3451w Burnsville Pkwy, Suite 120 Company City: Burnsville,MN 55337 Company Phone: 952-894-0005 Company Fax: 952-894-0925 Company Comment: i' T'.TT!t�r. _ A }, U (.. T ..I I.. .-.- •,. .i i .,.d�..rr i �,�. :�'F 1 5,i I l .t> _� J �F.�Si,'S�j XAj,'� Reference City: Minneapolis, Minnesota Building Orientation: Front door faces North Daily Temperature Range: Medium Latitude: 44 Degrees Elevation: 834 ft. Altitude Factor. 0.970 i Elevation Sensible Adj. Factor. 1.000 Elevation Total Adj. Factor 1.000 Elevation Heating Adj. Factor: 1.000 Elevation Heating Adj. Factor. 1.000 Outdoor Outdoor Outdoor Indoor Indoor Grains Dry Bub Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference Winter: -15 -15.33 80% n/a 72 n/a Summer. 88 72 47% 50% 75 29 S/�GL145Fe!'a�%rY$ i--F'`�, L 3 3 1 s i r - s.t` 1"+ ,� �1 - i*. `� � b �3 e.r.,, �-^��.: 1 �, y4 l s• � � � �� � `s �� ;Ti F''� +.:i�i} Total Building Supply CFM. 947 CFM Per Square ft.. 0.210 Square ft. of Room Area: 4,506 Square ft. Per Ton: 2,008 Volume (ft') of Cond. Space: 41,428 j' Y� .41q ;[` 4'iU .Cy'�• t.�. : tt {; V `iT 2�. aT1:'•tl{� �_}' .,t Eu.SJ-G ,+a,:: `t: iy.3 .•V:'a.{'a<.';. :_'L. "i�Y/�ny. `4 �£i�.,' 1`�:.:. '=�-Y•�.. v"T.J���: ,z -. {�' ...^," -'�4 i�vr,.hti't�'Y;k,G 'k,'tVti� :"'1 �.A.7.Jr�FI.O..,.Sdy}�,...i i�';v;�aF�,1.4$m ��'�1�3^:��h1 .f``.!}l; �`�.';4�v4"ih�u��%'?x.a...Ws. �i.. �%i'.. -"moi. eyf;'n44"�?:1���'.?21�tl+c`Y��� n i.�j.." Total Heating Required Including Ventilation Air: 69,867 Btuh 69.867 MBH Total Sensible Gain: 21,094 Btuh 78 % Total Latent Gain: 5,835 Btuh 22 % Total Cooling Required Including Ventilation Air. 26,929 Btuh 2.24 Tons (Based On Sensible + Latent) yj!�k T . F ` 1 1 FS ;1 v,4.. `:,U J LJ '-x•11 .,;. tl �Y * j .S Ch?1+�'.�l�T%k'`u��0.�.. 4'.. Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. C:\ ...\NJJ The Cape Cod w sport ct W.rhv Thursday. October 20. 2022. 11:41 PM C:\ ...WJJ The Cape Cod w sport ct W.rhv Thursday, October 20, 2022, 11:41 PM Rhvac ResidQntial S UgM Co fnmercRal HVAC Loads . gite $pfiware Dpveloprnent, Inc. Bumsvill Heatlng .B:A/C Inc The Cam hod With Spor# Ct , Bumsville MN 55337. (P ®10. Total Building Summary Loads :>r-s aw-`+''�y,�. rpt: � f 13 Xital, ti �.1*t.,♦♦��/; 1�''�A "'� �[[.'+� ��`�t ��7....`�_1"g fa- v �.c4a -�: `',z I � -". �y1_ °�,, 5: ,�" � ,�{.,.�ca. EH: Glazing-EH , ground reflectance = 0.23, u-value 200.5 4,881 0 2,288 2,288 I f 0.28, SHGC 0.22 EH: Glazing-EH, ground reflectance = 0.23, u-value 211.5 5,149 0 3,339 3,339 0.28, SHGC 0.22 EH: Glazing-EH , ground reflectance = 0.23, u-value 36 877 0 943 943 0.28, SHGC 0.22 hbt: Door- 20.4 266 0 73 73 hbt: Door- 19 232 0 64 64 12F-Osw: Wall-Frame, R-21 insulation in 2 x 6 stud 4388.3 24,814 0 3,793 3,793 cavity, no board insulation, siding finish, wood studs 15BO-15sf-8: Wall-Basement, , R-15 board insulation to 1095 4,261 0 89 89 { floor, no interior finish, 8' floor depth 1 R-49: Roof/Ceiling- 667.9 1,162 0 641 641 R-49-ad: Roof/Ceiling- 1112 1,935 0 1,068 1,068 19A-30p: Floor -Over enclosed unconditioned crawl 182 452 0 68 68 space, No insulation orr exposed walls, sealed or vented space, passive, R-30 blanket 20P-30: Floor -Over open crawl space or garage, Passive, 100.8 307 0 28 28 R-30 blanket insulation, any cover 21A-20-v: Floor-Basement, Concrete slab, any thickness, 1467.9 3,448 0 0 0 2 or more feet below grade, no insulation below floor, ! vinyl covering, shortest side of floor slab is 20' wide Subtotals for structure: 47,784 0 12,394 12,394 People: 6 1,380 1,800 3,180 Equipment: 400 3,600 4,000 Lighting: 0 0 0 Ductwork: 4,742 347 2,193 2,540 infiitration: Winter CFM: 116, Summer CFM: 0 10,744 0 0 0 Ventilation: Winter CFM: 192, Summer CFM: 192 6,596 3,708 879 4,587 AED Excursion: 0 0 227 227 Total Building Load Totals: 69,867 5,835 21,094 26,929 ' f IE ! Total Building Supply CFM: 947 CFM Per Square ft.: 0.210 Square ft. of Room Area: 4,506 Square ft. Per Ton: 2,008 Volume (ft') of Cond. Space 41,428 ,{i�1,J/-s.< �J`?Y.I:Tla 4;1 '�{'1r�L f...J. .�YS� }� F^ .yl 4 i j,. �.`�.21 S'> �sR' \� � A''�3V}7"`a.tf'T.� ,y.u} i4� `4Y�Ittt`•r"1X���,a2S iC '� y��i.t'S(�F ��,�� �' i''^ .�QIIi1�.. .� l., �r .,u.§., �.ai . ..5 �_++`°. r.,h`.-. .}F' �',.. r",�',k,. 1.�t olta.�d. �.w ,.L 1;G+.. ;�1��•-�,. I?:I;.:s_ ....r, _�.__1+. dr�. Total Heating Required Including Ventilation Air: 69,867 Btuh 69.867 MBH Total Sensible Gain: 21,094 Btuh 78 % Total Latent Gain: 5,835 Btuh 22 % Total Cooling Required Including Ventilation Air: 26,929 Btuh 2.24 Tons (Based On Sensible + Latent) . o� �tik. k�'<tv .rt^'`�.r..;':x,�*"Li°' �.Y�i;'^,.,`�.,'tic'�'�� .. _'$ �r, tu"�'wr:t=a',_;:.'?�,'•`�tr; Y ya a� ..y.`��',�irn'. _ "`} .-1;h'?1: , - - ?K^�.".�,..af... ..w: S.ro�a. .i�ir Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. C:\ ...WJJ The Cape Cod w sport ct W.rhv Thursday, October 20, 2022, 11:41 PM C:\ ...\NJJ The Cage Cod w sport ct W.rhv Thursday. October 20. 2022. 11:41 PM Rhvac Residential & Llght_Ccmmerclal HVAC Loads Bumswlle ;Heating 8A/C inc Elite Software Developmerrt, The CBpe`.C� W0 40 Ct B66 s016,**MN 55337.Pa' a 13 j System 1 Main Floor Summary Loads AYhC y.;A,.����F�f"'��YA T'-i.��T� f�.lfi,, �uy Y .'�Y}i .�.f �'4''9R0.§ A`o''.ti't.�y%=s`I .. �s.�SY ^tF F V�#i, 1,vtL`>�tf i'.c:, �t�•SJhK G. nj."c.M1 �l"i - f l EH: Glazing -EH, ground reflectance = 0.23, u -value 200.5 4,881 0 2,288 2,288 0.28, SHGC 0.22 EH: Glazing -EH, ground reflectance = 0.23, u -value 211.5 5,149 0 3,339 3,339 0.28, SHGC 0.22 IEH: Glazing -EH, ground reflectance = 0.23, u -value 36 877 0 943 943 0.28, SHGC 0.22 hbt: Door- 20.4 266 0 73 73 hbt: Door- 19 232 0 64 64 12F-Osw: Wall -Frame, R-21 insulation in 2 x 6 stud 4388.3 24,814 0 3,793 3,793 cavity, no board insulation, siding finish, wood studs 15BO-15sf-8: Wall -Basement, , R-15 board insulation to 1095 4,261 0 89 89 floor, no interior finish, 8' floor depth R-49: Roof/Ceiling- 667.9 1,162 0 641 641 R -49 -ad: Roof/Ceiling- 1112 1,935 0 1,068 1,068 19A -30p: Floor -Over enclosed unconditioned crawl 182 452 0 68 68 space, No insulation on exposed walls, sealed or vented space, passive, R-30 blanket j 20P-30: Floor -Over open crawl space or garage, Passive, 100.8 307 0 28 28 ( R-30 blanket insulation, any cover 21A -20-v: Floor -Basement, Concrete slab, any thickness, 1467.9 3,448 0 0 0 2 or more feet below grade, no insulation below floor, i vinyl covering, shortest side of floor slab is 20' wide Subtotals for structure: 47,784 0 12,394 12,394 People: 6 1,380 1,800 3,180 Equipment: 400 3,600 4,000 Lighting: 0 0 0 Ductwork: 4,742 347 2,193 2,540 f Infiltration: Winter CFM: 116, Summer CFM: 0 10,744 0 0 0 Ventilation: Winter CFM: 192, Summer CFM: 192 6,596 3,708 879 4,587 AED Excursion: 0 0 227 227 System 1 Main Floor Load Totals: 69,867 5,835 21,094 26,929 Supply CFM: 947 CFM Per Square ft.: 0.210 Square ft. of Room Area: 4,506 Square ft. Per Ton: 2,008 Volume (W) of Cond. Space 41,428 Total Heating Required Including Ventilation Air. 69,867 Btuh 69.867 MBH Total Sensible Gain: 21,094 Btuh 78 % Total Latent Gain: 5,835 Btuh 22 % Total Cooling Required Including Ventilation Air. 26,929 Btuh 2.24 Tons (Based On Sensible + Latent) Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. C:\ ...\NJJ The Cage Cod w sport ct W.rhv Thursday. October 20. 2022. 11:41 PM Rhyac Residential & LlghtCommprcla' HVAC Leads Ellte taoi The Gam Cod tware Develgpmenf, l Burnsville h�ea8ng & A!G Inc W Spprt Ct BUmWile,'MN 8633T'.Pa 16 t Syst—,e/]mY 1, Zone 1 Summary Loads (PeakLoadProcedure for Rooms) \�'+.FII�/n.F 4-.:.0 i �>~¢P. �i 4a �Y Ai,-� Ai � , �j✓i i. .:.'x4 T-=d°Lf�vf .rs Y�Af ln).i 3�5'nJ A�.�f���,.,}\� ':. tY,'�,✓�) ��.?.r'flu+.'+t�"r�$� WIC'. �a iY.n!/�r�l. .:t�,,,.��'-a^.i., .� ar. ,r _ x '•rC`..,I. �. ,r+a, l��l��, s.� _r., 'E• - EH: Glazing -EH , ground reflectance =`0.23, u -value 94 2,288 0 1,074 1,074 0.28, SHGC 0.22 EH: Glazing -EH, ground reflectance = 0.23, u -value 131 3,189 0 2,296 2,296 0.28, SHGC 0.22 EH: Glazing -EH, ground reflectance = 0.23, u -value 12 292 0 314 314 j 0.28, SHGC 0.22 hbt: Door- 20.4 266 0 73 73 hbt: Door- 19 232 0 64 64 12F-0sw: Wall -Frame, R-21 insulation in 2 x 6 stud 1448.7 8,193 0 1,252 1,252 cavity, no board insulation, siding finish, wood studs R-49: Roof/Ceiling- 177.6 309 0 170 170 Subtotals for structure: 14,769 0 7,088 7,088 People: 0 0 0 0 Equipment: 0 2,400 2,400 Lighting: 0 0 0 Ductwork: 1,494 0 972 972 Infiltration: Winter CFM: 40, Summer CFM: 0 3,670 0 0 0 ` System 1, Zone 1 Load Totals: 19,933 0 10,561 10,561 Ir. aii, sr t . rx i 2 4 sis.s x�-�ir a + y.s � 'ynr 3'� a i, -, y a �.f f,�4Y �k s ��'•r i "4 t ti Supply CFM: 495 CFM Per Square ft.: 0.345 Square ft. of Room Area: 1,435 Square ft. Per Ton: 1,631 Volume (ft') of Cond. Space: 14,665 3 ".' Total Heating Required: 19,933 Btuh 19.933 MBH Total Sensible Gain: 10,561 Btuh 100 % Total Latent Gain: 0 Btuh 0 % Total{ Cooling Required: yy 10,561 Btuh 0.88 Tons (Based On Sensible + Latent) Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. ! Be sure to select a unit that meets both sensible and latent loads. I I C:\ ...\NJJ The Cave Cod w snort ct W.rhv Thursday. October 20, 2022, 11:41 PM Rhvac R tder�tial 8 Light Commercial HVAC Loads Elite Software Development, tpc.: l3umshlle Heatlrtg A!C Inc The Cape Cod With Spon Ct Bumsvillsr MN 55337 17. System 1, Zone 2 Summary Loads (Peak Load Procedure for Rooms) �0 11egt��aJ'� 'k t '"4 _ �� f Y.S. � � < A � � '�niipl.1, � ➢5 ]7 d'a, .�. ���:l�F)fs '.-s4 K� i b 3-' � 9k., 4. .s.+✓2. ...� .. �.}C •,.. EH: Glazing -EH, ground reflectance = 0.23, u -value j 56 1,363 0 659 659 0.28, SHGC 0.22 EH: Glazing -EH , ground reflectance = 0.23, u -value 24 585 0 629 629 0.28, SHGC 0.22 EH: Glazing -EH, ground reflectance = 0.23, u -value 89 2,167 0 940 940 0.28, SHGC 0.22 12F-Osw. Wali -Frame, R-21 insulation in 2 x 6 stud 1164.6 6,585 0 1,007 1,007 cavity, no board insulation, siding finish, wood studs R-49: Roof/Ceiling- 490.3 853 0 471 471 R -49 -ad: Roof/Ceiling- 1112 1,935 0 1,068 1,068 19A -30p: Floor -Over enclosed unconditioned crawl 182 452 0 68 68 space, No insulation on exposed wails, sealed or vented space, passive, R-30 blanket 20P-30: Floor -Over open crawl space or garage, Passive, 100.8 307 0 28 28 R-30 blanket insulation, any cover Subtotals for structure: 14,247 0 5,923 5,923 People: 5 1,150 1,500 2,650 Equipment: 400 0 400 Lighting: 0 0 0 Ductwork: 1,384 0 761 761 Infiltration: Winter CFM: 31, Summer CFM: 0 2,836 0 0 0 System 1, Zone 2 Load Totals: 18,467 1,550 8,262 9,812 (y_�j.4.. h,`e ��. c IfI��Ts--.�� ..l- �•} 4` 5.it �- "F 1 � . 1 A !' .-' i ��� ' ..Ii -s d ] : } t.: .-G.14 x 4 � P . n`?I L-� y, Su'�_� Supply CFM: 387 CFM Per Square ft.: 0.241 Square ft. of Room Area: 1,603 Square ft. Per Ton: 1,960 Volume (ftp of Cond. Space: 12,818 01 Qlle� ,y ' _a ..,'1 :I. Ntr .. .A"' ,a:1 -9p. d5ii...A ,. t;.,,a?..Y'., •�.i�:>„�; 4-`4; �a ..�..;, Y„.,,�r_.-, a, �,...,. a, .1r Total Heating Required: 18,467 Btuh 18.467 MBH w Total Sensible Gain: 8,262 Btuh 84 % Total Latent Gain: 1,550 Btuh 16 % Total Cooling Required: 9,812 Btuh 0.82 Tons (Based On Sensible + Latent) .1,!. �. 'v�n:a 4 ]..�,yay-1 _ , F Sa €�..p, .-+�, ,y.�c �t� y ti vt tit '. �{1 .r,.w7 "� . ' .t' "'+' t sti ,x Q: •-c t'(. n. rv-`� '"'$ ; Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. I All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. CA ...WJJ The Cane Cod w snort ct W.rhv Thursdav, October 20, 2022, 11:41 PM Rhvec Residential & Light Commercial HVAC Loads Elite SoRware Developml�nt, Inc: f3urrisvifle,l 6i ' NC loc 9 The Cape Cod lNifh 5 . Ct BumsviAe, MN 55337 Page 18 System 1, Zone 3 Summary Loads (Peak Load Procedure for Rooms) I R 's ��..�ig�.� • ffzing-EH ,ground reflectance = 0.23, u -value 17.5 426 0 274 274 0.28, SHGC 0.22 EH: Glazing -EH, ground reflectance = 0.23, u -value 24.5 597 0 384 384 0.28, SHGC 0.22 12F-Osw: Wall -Frame, R-21 insulation in 2 x 6 stud 1775 10,036 0 1,534 1,534 cavity, no board insulation, siding finish, wood studs 15BO-15sf-8: Wall -Basement, , R-15 board insulation to 1095 4,261 0 89 89 floor, no interior finish, 8' floor depth 21A -20-v: Floor -Basement, Concrete slab, any thickness, 1467.9 3,448 0 0 0 I 2 or more feet below grade, no insulation below floor, vinyl covering, shortest side of floor slab is 20' wide i Subtotals for structure: 18,768 0 2,996 2,996 People: 1 230 300 530 Equipment: 0 1,200 1,200 Lighting: 0 0 0 Ductwork: 1,864 0 461 461 Infiltration: Winter CFM: 46, Summer CFM: 0 4,238 0 0 0 System 1, Zone 3 Load Totals: 24,870 230 5,004 5,234 NO 04few, Supply CFM: 234 CFM Per Square ft . y y0.160~ Square ft. of Room Area: 1,468 Square ft. Per Ton: 3,365 Volume (ft3) of Cond. Space: 13,945 Z6>te`Lpads a Total Heating Required: 24,870 Btuh 24.870 MBH Total Sensible Gain: 5,004 Btuh 96 % Total Latent Gain: 230 Btuh 4 % ATotal Cooling o oling Required: 5,234 Btuh 0.44 Tons (Based On Sensible + Latent) k ,-,'.-t,9•CM1'..? :7 .,,...� �x lY.''.r,>�ii..�+ f, , . ; ,,i , r hSk 4,y, .::V 'r �-k. ;,'"res 'i+a,«t*��� �1 .���'�";:t�:?��' ta2�r,,. �`.���#�,,. � �: Rhvac is an ACOA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. � I I CA ...WJJ The Cape Cod w snort ct W.rhv Thi irQdnw Opfnhcr 9n )mi 41 -Al CTIA C:\ ...WJJ The Cape Cod w soort ct W.rhv Thiircriav ni fnhar 7n 9n9,7 41 -Al oae Rhvac Resid�ral &Light Cgmntercial HVACLoads Elite SgftwA'e Oevelopme, inc Bumsvple;Heating`8A/C Inc The Cape Cod With4 Bumsviile; MN 55337 Detailed Room Loads - Room 77 - Basement (Peak Fenestration Gain Procedure) Room is in zone 3, which peaks at 2 pm Calculation Mode: Htg. & clg. Occurrences: 1 1 Room Length: 38.6 ft. System Number: 1 j Room Width: 38.0 ft. Zone Number. 3 Area: 1,468.0 sq.ft. Supply Air. 234 CFM Ceiling Height 9.5 ft. Supply Air Changes: 1.0 AC/hr Volume: 13,945.0 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 1 Actual Winter Vent.: 75 CFM j Runout Air: 234 CFM Percent of Supply.: 32 % j Runout Duct Size: 9 in. Actual Summer Vent.: 40 CFM Runout Air Velocity: 531 ft./min. Percent of Supply: 17 % Runout Air Velocity: 531 ft./min. Actual Winter Infil.: 46 CFM Actual Loss: 0.101 in.wg./100 ft. Actual Summer Infil.: 0 CFM - ... ,..,.,,. silte' �anN'01 r.cPtn�' ri, S -Wall-12F-0sw 38 X 9.5 319 0.065 5.7 1,804 0.9 0 276 N -Wall-I5BO-15sf-8 38 X 9.5 361 0.042 3.9 1,405' 0.1 0 29 W -Wall-1 5BO-1 5sf-8 38.6 X 9.5 367 0.042 3.9 1,428 0.1 0 30 E -Wall-I5BO-15sf-8 38.6 X 9.5 367 0.042 3.9 1,428 0.1 0 30 S -Wall-12F-0sw 38 X 9.5 361 0.065 5.7 2,041 0.9 0 312 N -Wall-12F-0sw 38 X 9.5 361 0.065 5.7 2,041 0.9 0 312 W -Wall-12F-0sw 38.6 X 9.5 367 0.065 5.7 2,075 0.9 0 317 E -Wall-12F-0sw 38.6 X 9.5 367 0.065 5.7 2,075 0.9 0 317 S -GIs-EH shgc-0.22 0%S 17.5 0.280 24.4 426 32.7 0 572 S -GIs-EH shgc-0.22 0%S 24.5 0.280 24.4 597 32.7 0 801 Floor -21A-20 38 X 38.6 1467.9 0.027 2.3 3,448 0.0 0 0 Subtotals for Structure: 18,768 0 2,996 Infil.: Win.: 45.6, Sum.: 0.0 1,992 2.127 4,238 0.000 0 0 Ductwork: 1,864 461 AED Excursion: 48 People: 230 [at/per, 300 sen/per. 1 230 300 Equipment: 0 1,200 Room Totals: I j 24,870 230 5,004 C:\ ...WJJ The Cape Cod w soort ct W.rhv Thiircriav ni fnhar 7n 9n9,7 41 -Al oae C ti�tderrtiel $� Light.CommQr+plai HVAC Loatls Mite Softtnrar� Davelopmerrt, Inc, t �umsville Heating 8'A/C II►p:�. � The Cape�Cod WRh Sport Ct i BumsyiUel MN 55337 Pa e.:4ti System I Room Load Summary - f f .r{aw�l,q �:<i, d1i �°- e "7 _3,bh" ..y,k+,-,� .' � �.^m 't�' cr i;.tt..'-, f1 r r: MR�i _� �Fj lF+s�-v,•'� '`5 1a... .y., tZ'. fr.. "..;z'p b��; , �� .�...' : �' r ��,.��'ee�``� � C,z�'srit� � �.'-�: �i �'sw > c yo,�' .,�. , �G4 ,,�"'��,�'^`{-�r,��� .� ,.�'y"� ��� •� �$�$..�,C � ,cf ���iw� h s: - _J " -Zone 1- 1 Foyer 84 2,477 33 1-3 559 585 0 27 27 2 Den 154 3,303 44 1-5 379 1,102 0 52 52 3 Stairs 173 905 12 1-4 232 432 0 20 20 i 4 Great Room 299 4,390 59 1-6 528 2,214 0 104 104 5 Dining 131 3,701 50 1-7 459 2,619 0 123 123 6 Kitchen 329 1,218 16 1-7 493 2,811 0 132 132 7 Mud Room 219 3,111 42 1-3 375 393 0 18 18 8 Tech Center 46 828 11 1-3 387 405 0 19 19 Zone 1 subtotal 1,435 19,933 267 10,561 0 495 495 , -Zone 2- 9 Loft 257 3,821 51 1-6 527 2,207 230 103 103 10 Bedroom 3 198 2,703 36 1-4 678 1,262 230 59 59 11 J & J Bath 133 781 10 1-2 435 203 0 9 9 12 Bedroom 2 187 1,496 20 1-4 599 1,116 230 52 52 13 Master Bedroom 292 3,337 45 1-5 .633 1,841 460 86 86 14 Master Bath 281 3,156 42 1-3 674 706 0 33 33 15 Bedroom 4 154 2,653 36 1-4 423 788 0 37 37 16 Laundry 101 521 7 1-2 299 139 400 7 7 Zone 2 subtotal 1,603 18,467 247 8,262 1,550 387 387 -Zone 3- 17 Basement 1,468 24,870 333 1-9 531 5,004 230 234 234 Zone 3 subtotal 1,468 24,870 333 5,004 230 234 234 Ventilation 6,596 879 3,708 Duct Latent 347 System 1 total 4,506 69,867 847 21,094 5,835 947 947 System 1 Main Trunk Size: 11x16 In. Velocity: 775 ft./min Loss per 100 ft.: 0.093 in.wg Note: Since the system Is multizone, the Peak Fenestration Gain Procedure was used to determine glass sensible gains at the room and zone levels, so the sums of the zone sensible gains and airflows for cooling shown above are not intended to equal the totals at the system level. Room and zone sensible gains and cooling CFM values are for the hour in which the glass sensible gain for the zone is at its peak. Sensible gains at the system level are based on the "Average Load Procedure + Excursion" method. r, zi�,"� f1 .� `;'M.,-rt.'�-u°`,r i .tm� fit �•�b" -+ �'9.`., n x..a`.''�*�;.��'�`:d i.. -� .� u r �-Ai-s-,��"3 ,fi �4 �' i Net Required: 2.24 78% / 22% 21,094 5,835 26,929 QX ...WJJ The Cape Cod w sport ct W.rhv Thursday. October 20. 2022. 11.41 PM New Construction Energy Code Compliance Certificate Per R401.3 Certificate. A building certificate shall be posted on or In the electrical distribution panel. Date C ertificate Posted 10/21/2022 Place your logo here Mailing Address of the Dwelling or Dwelling Unit City 1413 Vince Trail Eagan Name of Residential Contractor MN License Number Etemity Homes LLC BC638704 THERMAL ENVELOPE RADON CONTROL SYSTEM Insulation Location G ra C �° o N .S Type: Check All That Apply X Passive (No Fan) Q z o z av m N . m a ti m N m .mo E m C) m 0 u- c K 0 m o u. u- - m c c v' LLLL!! v rn L° H v rn R AcOve (With fan and mmrometer or other systemrwnfladngdeNce) Location (or future location) of Fan: Other Please Describe Here Below Entire Slab Foundation Wall 10 X Perimeter of Slab on Grade 15 X Rim Joist (1 at Floor) 21 X Rim Joist (2nd Floor+) 21 X Wall 20 X Ceiling, flat 49 X Ceiling, vaulted 49 X X Bay Windows or cantilevered areas 30 X Floors over unconditioned area 30 X Describe other insulated areas Building envelope air tightness: Duct system airtightness: Windows & Doors Heating or Cooling Ducts Outside Conditioned Spaces Average U -Factor (excludes skylights and one door)U: 0.28 X Not applicable, all ducts located in conditioned space Solar Heat Gain Coefficient (SHGC): 0.22 R -value R-8 in garage area MECHANICAL SYSTEMS I Make-up Air Select a Type Appliances Heating System Domestic WaterCoolingSystem Heater X Not required per mech. code Fuel Type Gas Gas R -410A Passive Manufacturer Dalkin A.O Smith Daikin Powered Model DM92SNO803B DX13SNO36 Interlocked with exhaust device. Describe: Rating or Size Input in 80,000 cwdb In BTUS: aafl°ns: 50 Output 2.5 in Tons: Other, describe: Efficiency AFUE or 92% SEER 13 HSPF% I /EER Location of duct or system: Residential Load Calculation Heating Loss Heating Gain Cooling Load 69,867 21,094 26,969 Cfm's ° round duct OR MECHANICAL VENTILATION SYSTEM "metal duct Describe any additional or combined heating or cooling systems if installed: (e.g. two furnaces or air source heat pump with gas back-up furnace): Select Type Combustion Air Select a Type Not required per mech. code 6" Passive X Heat Recover Ventilator (HRV) Capacity in cfms: Low: 82 High: 1 190 Other, describe: Energy Recover Ventilator (ERV) Capacity in cfms: Low: High: I Location of duct or system: Balanced Ventilation capacity in cfms: Location of fan(s), describe: I Cfm's Capacity continuous ventilation rate In cfms: " round duct OR Total ventilation (intermittent + continuous) rate in cfms: " metal duct Builders Associaton of Minnesota version 101014 ADDRESS: 1413 VINCE TRAIL REVIEWED FOR CODE COMPLIANCE3:1 MAX. SLOPES OR 41`2-10-11 RETAINING WALL REQUIRED EAGAN INSTALL PERIMETER ° '"�""�`CONTROL 0910%20= 127:12 PM ENGINEERING NOTE.• ALL BUILDING DIMENSIONS ARE SHOWN TO OUTSIDE OF FOUNDA77ON WALL LOT AREA = 16,309 SQ. FT. HOUSE AREA = 2,142 SQ. FT. SETBACK INFORMATION: FRONT = 30' SIDE YARD = 10' (HOUSE) SIDE YARD = 5' (GARAGE) REAR YARD = 15' (HOUSE) REAR YARD = 5' (SHED) IS, 7REE TABLE CERTIFICATE OF SURVEY FOR ETERNITY HOMES LLC 8?1.8 M NC WNCRETEI TNHCB94 O �=8o43'O-5" 893 894.4- _"_ �- _ 896-C 89 .3 -895s1 '� ti 0 0i 0 w CV N O O 0 Z CCU 46.9 �5TOP I N89055'38"W 4.00 TAG# SPECIES. DIAMETER CONDITION 0 01 COTTONWOOD, EASTERN 35 p GOOD DENOTES PROPOSED DRAINAGE DIRECTION 02 COTTONWOOD, EASTERN 280 GOOD 000.0 03 COTTONWOOD, EAS7ERN 280 GOOD DENOTES EXISTING CONTOUR 04 BIRCH, PAPER 14" FAIR CO'� 05 MAPLE, SILVER 280 GOOD DENOTES BITUMINOUS SURFACE 06 ASH, GREEN 24" GOOD 00 07 CRABAPPLE 06" FAIR 08 CRABAPPLE 09 p FAIR p 09 CRABAPPLE 060 FAIR �^ 10 MULBERRY, RED 12" GOOD w 11 MULBERRY, RED 120 FAIR co d" N O NOTE. TREE TABLE INFORMATION WAS TAKEN FROM C) THE 7REE PRESERVATION PLAN PREPARED BY 0 REHOER FORE57RY CONSUL77NG DA7ED 1-20-21 0 DENOTES MAILBOX 0 DENOTES IRON PIPE MONUMENT SET 0 DENOTES FOUND IRON PIPE MONUMENT DENOTES PROPOSED DRAINAGE DIRECTION ' DENOTES SERVICE LOCATION I] DENOTES WOOD HUB 000.0 DENOTES EXISTING ELEVATION ® DENOTES PROPOSED ELEVATION bop- DENOTES EXISTING CONTOUR DENOTES DECIDUOUS TREE - y 1 I CO'� DENOTES EVERGREEN TREE DENOTES BITUMINOUS SURFACE DENOTES CONCRETE SURFACE DENOTES GRAVEL SURFACE 908.3 8 909.3x x N T Z N I ' 908.7 x 899.5 CENTERLINE E TRAIL ;K UNE - / , x 9ooir Gk9°4,� to 896.2 r 98.6 J 902.9 im-Xz903.4 0272' '/ PROPOSED. I I 'YiJVEWY I 9.G% 902 I y9r 9.l x 903.1 /xI q0 a _ I '15.6 ' 21.0 / f .903.7 0200-. 19 a 9 Ax ,n /i x PO =906.2 O i 120 n 04.6 GARAGF� �NOTE: ADD 3 EXTRA /� o P5 BETWEEN T k i o HOUSE AND GAE J / C\1 9 �i TR -7 p ' a� ate: 5.6 5 / y O / Q O 7.0 A 1.1 MD. m x 904.7 x 90 .8 1O T PROPOSE 8 °� °'k 2-STOR *.5 �Ij I, °_' I FB/FLAC ° 19.0 W/W o o W/W O CD 13.0 l4 0 906.1 °j f I 2 PROPOSED RETAINING WALL X -9052 S ic-) N 0 LU 0 co O Z X 9072 1908.7 908.9 / S. i'ly/ �o G� F 913.1 909.8 7 912.1130 ON.5 914.5 914.9 915.7 N89°56'20"W 77.00 FE CE 915.3 NOTE.• ADD 3 EXTRA STEPS BE7WEEN THE HOUSE AND GARAGE = 2.2 PROPOSED TOP OF WALL ELEV. = 905.2 PROPOSED GARAGE FLOOR ELEV. = 903.0 PROPOSED BASEMENT FLOOR ELEV. = 897.5 PROPERTY DESCRIPTION LOT 1, BLOCK 1, KENNERICK THIRD ADDITION, CITY OF EAGAN, DAKOTA COUNTY, MINNESOTA. Bohlen I HEREBY CERTIFY THAT THIS SURVEY WAS PREPARED BY ME OR Surveying &Associates UNDER MY DIRECT SUPERVISION AND THAT I AM A DULY LICENSED LAND SURVEYOR UNDER THE LAWS OF THE STATE OF MINNESOTA 31432 Foliage Avenue 1682 Cliff Road E Northfield, MN 55057 Bumsvfile, MN 55337 Phone: (507) 645-7768 B A Phone: (952) 895-9212 DATE: 8-31-2022 t t IurlNo J� R tomeara@bohlensurveying.com Fax: (952) 895-9259 THOMAS E LAND SURVEYOR MINNESOTA LICENSE N0.46167 F:\Projects\Eagan\kennerick-third-addition\dwg\L1B1-cert-8-24-22.dwg 8/24/2022 7:18:12 AM CDT LO I 90g � 0 9082 I ® ® 909 x 909.4l`u/ I � x 911.0 I I - y 1 I CO'� /g10'f nl BLOCS 4- / I I1� T 9 I 0� � Z x 911.E x911.3 I I /x 913.1 I 7L �^ 5 >U910.9 1 / � 914.0x, I / x 913.4 ��� 5 912.0 I _�, -� D AGE 4 UTILITY EASEIyAT � of - otst �9t� 7 912.1130 ON.5 914.5 914.9 915.7 N89°56'20"W 77.00 FE CE 915.3 NOTE.• ADD 3 EXTRA STEPS BE7WEEN THE HOUSE AND GARAGE = 2.2 PROPOSED TOP OF WALL ELEV. = 905.2 PROPOSED GARAGE FLOOR ELEV. = 903.0 PROPOSED BASEMENT FLOOR ELEV. = 897.5 PROPERTY DESCRIPTION LOT 1, BLOCK 1, KENNERICK THIRD ADDITION, CITY OF EAGAN, DAKOTA COUNTY, MINNESOTA. Bohlen I HEREBY CERTIFY THAT THIS SURVEY WAS PREPARED BY ME OR Surveying &Associates UNDER MY DIRECT SUPERVISION AND THAT I AM A DULY LICENSED LAND SURVEYOR UNDER THE LAWS OF THE STATE OF MINNESOTA 31432 Foliage Avenue 1682 Cliff Road E Northfield, MN 55057 Bumsvfile, MN 55337 Phone: (507) 645-7768 B A Phone: (952) 895-9212 DATE: 8-31-2022 t t IurlNo J� R tomeara@bohlensurveying.com Fax: (952) 895-9259 THOMAS E LAND SURVEYOR MINNESOTA LICENSE N0.46167 F:\Projects\Eagan\kennerick-third-addition\dwg\L1B1-cert-8-24-22.dwg 8/24/2022 7:18:12 AM CDT