Loading...
EA178738 - Building - Single Fam - Issued Date 11/28/2022 (2) PERMIT City of Eagan , , , Permit Type: Building 3830 Pilot Knob Rd Permit Number: EA178738 Eagan, MN 55122 --• -- EAGAN (65 1)675-567.5 1111111111111 IN 1111111 www.cityofeagan.com * E R 1 7 8 7 3 8 Date Issued: 11/28/2022 Site Address: 1413 Vince Tr Lot: 1 Block: I Addition: Kennerick 3rd PID: 10-41502-01-010 111111111111111111111 lux= MR Use: * 10 - 4 1 S02 - 0 1 - 0 10 * Description: Sub Type: Single Fam Construction Type: V-B Work Type: New Description: Census Code: 101- Single Family Houses Occupancy: IRC-1 Zoning: R-1 Square Feet: 0 Comments: Improvements to the home may require smoke detectors in all bedrooms. Carbon monoxide detectors are required within 10 feet of all sleeping room openings in residential homes(Minnesota State Building Code). Fee Summary: 3/4"Meter $300.00 6101.4509 BL-Base Fee $3,018.75 0801.4085 Valuation: 426,998.00 City SAC(01 Unit) $131.50 9376.4681 Plan Review $1,962.19 0720.4222 Radio Read Unit(Domestic) $205.00 6101.4509 Sewer Permit $64.00 6201.4532 Surcharge-Based on Valuation $213.50 9001.2195 Surcharge-Fixed $1.00 9001.2195 Treatment Plant-Residential $1,065.50 6101.4685 Water Permit $64.00 6101.4507 Water Supply& Storage $1,715.10 6101.4680 SAC(1 unit)- Single Family House $2,485.00 9220.2275 Tree Preservation Performance Guarantee $5,000.00 9111.2257 Total: $16,225.54 Contractor: Owner: - Applicant - Eternity Homes LLC 425 Third St Farmington MN 55024 This permit shall be null and void if work does not start within 180 days of issuance,or if work is suspended for 180 days or more after started. I hereby acknowledge that I have read this application and state that the information is correct and agree to comply with all applicable State of Minnesota Statutes and City of Eagan Ordinances. Applicant/Permitee: Signature sued B : Signature 5 a s a P,l I T K 1 3 r; -- -$I i , ,�2 S s� / ft-- lqF-f3Io U. �j2 e� t1n 4 1 T 9 If I ') C,. For Office Use d �L I3 p I '� Permit#: t EAGA ds'-'• I I Permit Fee: t � Date Received: I I I 3830 PILOT KNOB ROAD I EAGAN, MN 55122-1810 r G 3 � 2022 � (651)675-5675 1 FAX: (651)675-5694 I Staff: I buildinginspectionsCcDcltyofeagan.com --————————————————J BY: 2021 RESIDENTIAL BUILDING PERMIT APPLICATION Date: b�( 1413 Vince Trail �,Ji 22•- Site Address: Unit#: Name: Eternity Homes LLC Phone: 651-460-3043 Resident/ 425 3rd St / Farmington / 55024 Owner Address/City/Zip: Applicant is: Owner */ Contractor owner Email: coraleternityhomesllc@gmail.com Type of Work Description of work: New Construction Construction Cost: $400,000 Multi-Family Building: (Yes /No X ) Company: Eternity Homes LLC Contact: Coral Ozmun Contractor Address: 425 3rd St City: Farmington State: MN Zip: 55024 Phone: 651-460-30 Email: coraleternityhomesllc@gmail.com License#: BC638704 Lead Certificate#: If the project is exempt from lead certification, please explain why: COMPLETE THIS AREA ONLY IF CONSTRUCTING A NEW BUILDING In the last 12 months, has the City of Eagan issued a permit for a similar plan based on a master plan? Yes N No If yes, date and address of master plan: Licensed Plumber: S��il�Gt�t� C 'Ul/Yl��;��� "l L Phone: �� �� �✓j Mechanical Contractor: 7 )i"[AL V1 �t 14-(-Y1+(( 1,1,G1 Phone: 0`J L-yrl�"� —G- r Sewer&Water Contractor: Phone: W 15 1 Fire Suppression Contractor: Phone: NOTE:Plans and supporting documents that you submit are considered to be public information. Portions of the Information may be conclude that thev are trade secrets. You may subscribe to receive an electronic notification from the City of proposed ordinances by signing up for an email update on the City's website at www.citvofeagan.com/subscribe. CALL BEFORE YOU DIG. Contact Gopher State One Call at(651)454-0002 or www.gor)herstateonecall.org for protection against underground utility damage. Contact Gopher State One Call 48 hours before you intend to dig to receive locates of underground utilities. I hereby acknowledge that this information is complete and accurate;that the work will be in conformance with the ordinances and codes of the City of Eagan; that I understand this is not a permit, but only an application for a permit, and work is not to start without a permit; that the work will be in accordance with the approved plan in the case of work which requires a review and approval of plans. X Coral Ozmun X -- Applicant's Printed Name Applicant's Signature FOR OFFICE USE ONLY Site Address: ) � y ' h`'- T12- Permit#: ) T� �3 SUB TYPES _ Foundation _ Fireplace — Porch (3-Season) — Miscellaneous Single Family Garage — Porch (4-Season) _ Accessory Building Multi _ Deck Porch (Screen/Gazebo/Pergola) 01 of Plex Lower Level Pool WORK TYPES New _ Repair _ Siding — Retaining Wall _ Addition — Fire Repair _ Reroof — Move Building _ Alteration Water Damage Windows Demolish Building* — — — _ Replace _ Egress Window — Solar *Demolition of entire building–give PCA handout to applicant DESCRIPTION f Calculated Valuation 12-41Pj4Io 8' _ Occupancy 112C-i MCES System X Plan Review Code Edition ,*VR C.-2.0Z,p SAC Units .'�.. (25%-100% � ) Zoning Q•�, City Water Census Code Stories Booster Pump #of Units Square Feet PRV #of Buildings Length _ Fire Suppression Required Type of Construction \j13 Width REQUIRED INSPECTIONS Footings(New Building) Meter Size: Footings(Deck) Final/C.O. Required Footings (Addition) Final/No C.O. Required Foundation Foundation Before Backfill HVAC_Service Test Gas Line Air Test—Hood (Z Roof: K Ice&Water k Final Pool:—Footings —Air/Gas Tests _Final X Framing 30 Minutes X- 1 Hour Drain Tile Fireplace:—Rough In _Air Test ___Final k Siding:_Stucco Lath KStone Lath _Brick_EFIS Insulation Windows Sheathing Retaining Wall:—Footings_Backfill_Final Sheetrock Radon Control Fire Walls Fire Suppression:_Rough In_Final Braced Walls Erosion Control Shower Pan Other: 44/�--- Reviewed By: , Building Inspector RESIDENTIAL FEES -S Calculated Calculated Valuation �Z�.�g• �a � • 23� ��b.5d I Five slrjed IO�y� 55.?3 = 102.1330.3* Base Fee Plan Review 833 k 4'0.q1 % 33,"1. S3 State Surcharge /SH F/oc+r : 130�j X 9 s. 73 s/25,3►D.5� MCES SAC Z Floor • 409/ X 95;. 73 S. City SAC Utility Connection Charge Y2G, 998, 4a S&W Permit&Surcharge Treatment Plant Radio Read Other: Copies: TOTAL $0.00 ------------------------- For Office Use 0 I Stormwater Management Permit#: I EAGAN Building Permit#: 1 I I Escrow Deposit: 221 r I I 3830 PILOT KNOB ROAD I EAGAN, MN 55122-1810 1 (651)675-5300 waterres(cDcitvofeagan.com I Staff: I -------------------------' STORMWATER MANAGEMENT PERMIT Date: 2- Site Address: 1413 Vince Trail i Description of Project: New Construction Area of Land Being Disturbed: 2)707 Start Date: Completion Date: ❑ Please submit a Land Disturbance and Stormwater Pollution Prevention Plan with this application. Name: Eternity Homes LLC Phone: 651 -460-3043 Address/City/Zip: 425 3rd St / Farmington / 55024 Property Owner Contact: Coral Email: draftingeternityhomesllc@gmail.com Applicant is: Owner Contractor Name: Eternity Homes LLC License#: BC638704 425 3rd St Farmington Address: City: Contractor State: MN Zip: 55024 Phone: 651-460-3043 Contact: Coral Email: draftingeternityhomesllc@gmail.com Erosion and Sediment Control Performance Security The City requires an escrow deposit to secure performance of erosion and sediment control(ESC)requirements, including proper installation and maintenance. The security shall pay for any City costs or expenses to bring the site into compliance with the Stormwater management permit, including any engineering, legal,or administrative expenses; inspections;and necessary work by City contractor(s). The City may extract from the security escrow. The escrow deposit will be released only upon inspection and written notice of conformance by the City. The following escrow deposits include two(2)required City inspections,initial and final. Existing Single-Family Residential Lot(addition,demolition,pool, retaining wall,etc.) $1,300/lot New Single-Family Construction $3,900/lot Multi-Family or Commercial Construction(new,addition,demolition) $6,500/acre' 'Maximum of$12,000 Erosion and Sediment Control Reinspection Fee(for as needed City reinspections after the two(2)included) $85/trip Security Amount: 3900 The applicant assumes all responsibilities for installation and maintenance of pollution prevention practices on this site. Any violations of City Code identified by the City shall be addressed within 48-hours of service of the notification. The applicant understands that failure to maintain pollution prevention practices within the time allotted by the City notification, will result in enforcement action to correct site deficiencies that are in violation of Sec. 4.34. The issuance of this permit constitutes a right-of-entry of the City or its contractors to enter upon the construction site for the purpose of completing ordinance enforcement and/or completing corrective work. I hereby acknowledge that this information is complete and accurate;that the work will be in conformance with the ordinances and codes of the City of Eagan;that I understand this is not a permit, but only an application for a permit, and work is not to start without a permit; that the work will be in accordance with the approved plan in the case of work which requires a review and approval of plans. The undersigned accepts full responsibility for compliance with the Stormwater Management Ordinance of the City of Eagan and agrees to comply with the Stormwater Pollution Prevention Plan or equivalent in full. X Coral Ozmun X 0z)-k� Applicant's Printed Name App icant's Signatur Performance Security Release The following information will determine to whom the escrow deposit will be returned. Security will be returned in the form of a check. Name: Eternity Homes LLC Address/city/zip: 425 3rd St / Farmington / 55024 Phone: 651-460-3043 Email: invoicingeternityhomesllc@gmail.com Amount: $3,900 Permit Number: FOR OFFICE USE ONLY SUB TYPE WORK TYPE _ Stormwater Management Permit Apartments Commercialllndustrial Multi Family Public Facility Single Family DESCRIPTION _ Addition Demolition Pool X New Retaining Wall Other: REQUIRED INSPECTIONS � j initial Inspection XFinal Inspection SECURITY $3,900 Erosion and Sediment Control Deposit(6501.2257) Other: Total: $3,900 10/27/2022 Reviewed By: ' key , ater Resources Date: i i I I _ City Inspection Dept. Copy EAGAN City Forester Copy Applicant/Builder Copy INDIVIDUAL RESIDENTIAL LOT TREE PRESERVATION PLAN SUMMARY CITY OF EAGAN FORESTRY DIVISION 651-675-5300 (BUILDER, PLEASE READ ATTACHMENTS) Development Kennerick 3rd Addition Lot Number 1 Block Number 1 Address 1413 Vince Trail Builder Eternity Homes, LLC Phone Number: 651-460-3043 Contact: Coral Tree Protection Requirements: X Tree Protection Fencing to be Installed on Site(Orange Poly Fence) Oak Tree Pruning(immediately seal wounds during April 1 to Jul 31 ) Therapeutic Pruning Required Retaining Wall To Be Installed Other: Replacement Trees: X Not Required: Cash dedication in lieu of planting As Follows: ..moo Attachments: X Yes (Refer to attach d rGAN FORESTRY DIVISION No �/yla V �'lJ REVIEWED Additional Notes: BY .J►&- L ri)a- DATE lot-717--r, TREE o[-7lZ-r, TREE PRESERVATION PLAN-413 Vince Trail,docx 1413 Vince Trail xx� ~' Y • ��k � ; 1f a t' i1 5 � 1 LL�T� T yds a ., } `SJI ., _ x i 11 �t lig ,�4.._ \ � � 1' �.. _ -r .♦ `fit - Met a 1 in=94ft Lakes ; lf : f Storm Basin Nn Wetlands EAGANSections Numbers Aerial Street Names aty of Eagatoisn Ocer 7,202, Map Powered by DataLink ADDRESS: 1413 VINCE TRAIL CERTIFICATE OF SURVEY FOR ETERNITY HOMES LLC NOT11%4 VINCE TRAIL DIMENSIONS ALL BUILDING = -O'CRETE C1Re 46U71LR DIMENSIONS ARE SHOWN TO -A=8'43'0 U s9. �,:,��89 OUTSIDE OF FOUNDA77ON BENCHMARK: A-8'43'0 ° a 9 :s- 696.2 WALL TN 894.60 't-20•v1Y '' -2 98.6 d95'/' _ 87. "-ESTOP .•i •�.�. - LOT AREA - 16,309 SO. FT. ter- _ Imo. HOUSE AREA - 2,142 SO. FT. 5 r es)`.s r J ( 6 X03.9 IY �x 903.4 8994 x899.3 / �: 7 �."• r SETBACK INFORMATION: FRONT=30' --- K UNE _ / PROP03ED SIDE YARD=10'(HOUSE) n I ) /4 T R i ALLNO C73 900 T.�-. 931Y .� 9051 SIDE YARD=5'(GARAGE) i x ® o REAR YARD=15'(HOUSE) LU / REAR YARD=5'(SHED) CV ,,5IjOP05ED I 2I u1 Iz�l �PJVEWyT I 5.9 - V p I 9.6 I O I Z /x 903.1 S S CO I I o I .90J.X 20.0- I e -906.2 Ow 1.9W x I 906.6 n iz. o /GARAGF/ �, x97.2 8.0 yyOOTTE:ADD 3 EXTRA P5 8[7M4EN T 1 n-20' $ HOUSE ANO GAE y, O N89°55'38"W 7.0 11.1 .7 4.00 x9a� T e PROPOSE e 7 4% I i ¢ TREE TABLE _ / 2-STOR .s I ii sc TAG/SPECIES. Di AMETER COND177ON FB/PI, `SSSGGGeee111'"' '9�{ O1 COTTONWOOD, EASTERN 35" GOOD 19.0 /140' 02 COTTONWOOD, EASTERN 28 GOOD wm o wm 03 COTTONWOOD, EASTERN 28" GOOD I 13.0 tD 04 BIRCH, PAPER 14" FAIR ._- y�.1I 913.1 05 MAPLE, SILVER + 28" GOOD ® I II 9099 06 ASH, GREEN 24" GOOD 07 CRABAPPLE 06" FAIR 08 CRABAPPLE 09" FAIR N95 0 .. � I 7 �O 09 CRABAPPLE O6" FAIR I� r ��� , M � 10 MULBERRY, RED 12" GOOD W r 4 ® (� r W] 11 MULBERRY, RED 12" FAIR I 00 itx9081 ® ~�'x 909.4 0�i 2 /911.0 NOTETREE TABLE INFORMA71ON WAS TAKEN FROM O I /~ f I ® --•' /, THE 7REE PRESERVA77ON PLAN PREPARED BY OI00 I REHD£R FORESTRY CONSULTING DATED 1-20-21 Z lI-EOT I e /... BLOCK 4-- 996.3 O X Z x9113, I ..� 1911.1 I�____ -j / > x917.4 91 I ...-•.-" � 5 �81910.9 I _F912.D 1 s ® DENOTES MAILBOX W 11 0 9" 90' 4"x911 D E4 UTILITY 91 O DENOTES IRON PIPE MONUMENT SET - • - • - 912.1 917.5 10 � 94.3 91 s.I 913.7 DENOTES FOUND BION PIPE MONUMENT y N89e56'20"W 77.00 P 915.3 908.7 �- DENOTES PROPOSED DRAINAGE DIRECTION 1 DENOTES SERVICE LOCATION NOTE:ADD 3 EXTRA S7EPS BETWEEN THE HOUSE AND GARAGE= 2.2 O DENOTES WOOD HUB PROPOSED TOP OF WALL ELEV. - 905.2 000.0 DENOTES EXISTING ELEVATION PROPOSED GARAGE FLOOR ELEV. - 903.0 1EM DENOTES PROPOSED ELEVATION PROPOSED BASEMENT FLOOR ELEV. -897.5 DENOTES EXISTING CONTOUR PROPERTY DESCRIPTION DENOTES DECIDUOUS TREE LOT 1,BLOCK 1,KENNERICK THIRD ADDITION, CITY OR EAGAN,DAKOTA COUNTY,MINNESOTA. DENOTES EVERGREEN TREE Bohlen I HEREBY CERTIFY THAT THIS SURVEY WAS PREPARED BY ME OR DENOTES BITUMINOUS SURFACE Surveying&Associates UNDER MY DIRECT SUPERVISION AND THAT I AM A DULY LICENSED LAND SURVEYOR UNDER THE LAWS OF THE STATE OF MINNESOTA. ,. 31432 FOBaga Avenue 1682 COR Rx a E. DENOTES CONCRETE SURFACE NM geld,MN 55057 8_vft,MN 55337 TL - , T�x�, m Q DATE: 8-31-2022 1(1RP{g ala(.J-u • Phone'.(57)645.7788 m Phone:(952)8958212 THOMAS J.O'MEA DENOTES GRAVEL SURFACE lomeara®1wHlenaurvey4lg.com Fax:(852)695-9259 RA,LAND SURVEYOR MINNESOTA LICENSE N0.48187 FAProjcctslEagan\k=crick-third-additioD\dwg\LIBI-=-8-24-22.dwg 824/2022 7:18:12AMCDT TREE PRESERVATION PLAN REVIEW-INDIVIDUAL LOT EAGAN Date Building Permit Application Received 8/31/22 Development Kennerick 3rd Addition Lot 1 Block 1 Site Address 1413 Vince Trail Builder Eternity Homes, LLC Contact Coral Telephone 651-460-3043 E-mail coraleternityhomesllc(cDgmail.com Property/Lot Owner Name Telephone E-mail Office Plan Review-Date 9/12/22 Notes Tree inventory was submitted with the certificate of survey with this application. Site contains 11 significant trees, less 1 Ash. Of the ten significant trees, seven are proposed for removal. The removal of significant trees over the allowable removal limit calculates to required mitigation of 10 Category B trees, or cash equivalent of$5,000.00. Request for decision sent 9/12, Response received 10/3 Tree Preservation Data Original Plan Revised Plan Total Significant Woodland Area sq.ft sq.ft Total Significant Trees 10 Woodland To Be Removed sq.ft sq.ft Trees To Be Removed 7 Allowable Woodland Removal (20%) sq.ft sq.ft Allowable Tree Removal(20%) 2 Required Mitigation YES (or) NO Calculated Mitigation Amounts Original Plan- Category A 10 Category B Category C Revised Plan- Category A Category B Category C Site Inspection—Date 9/12/22 Notes Home Location not staked. Ash tree is in fair condition but is untreated and should be removed. G:\Forestry\TreePreservation\Tree Preservation Plan Review-Individual Lot.docx Original Tree Preservation Plan Approved—Date 10/7/22 By Forwarded to Inspections—Date 10/7/22 By Discussion/Meetings with Builder/Owner- Coral/Eternity 10/3 Notes Applicant has indicated that the buyers/will pay the dedication Completed permit review will be forwarded today (10/7) Revised Tree Preservation Plan Approved—Date By Forwarded to Inspections—Date By Additional Field Inspections Date Notes Date Notes Date Notes Date Notes G:\Forestry\TreePreservation\Tree Preservation Plan Review-Individual Lot.docx KENNERICK 3rd ADDITION LOT 1 BLOCK 1 -TREE PRESERVATION CALCULATION WORKSHEET 9/6/2022 Property Address: 1413 Vince Trail Development Type= Single Family Residential Existing Allowable Actual Actual Required Cash Trees Removal Removal Preserved Mitigation Equivalent 10 Trees 20.0% 7 Trees 3 Trees 5 B trees $2,000 2.0 Trees 70.0% 30.0% INDIVIDUAL TREE MITIGATION CALCULATION DETAILS (Applicant to mitgate: 5 Trees) Category of Tree Number of Mitigation Total Total To Be Removed Trees Removed Per Tree(B) Mitigation(B) Mitigation(A) Specimen Trees 0 6 0 0 Hdwd Deciduous 21-30" 0 4 0 0 Soft Deciduos>24" 0 4 0 0 Conifer>24'(12"dbh) 0 4 0 0 Hdwd Deciduos 6-20" 2 2 4 2 Soft Deciduous 12-24" 3 2 6 3 Conifer 12-24'(<12"dbh) 0 2 0 0 5 Cat.A trees total= 5 TREE MITIGATION= 10 Category B Trees QUANTITY OF MITIGATION TREES PROVIDED= 0 Category B Trees Balance of mitigation trees to be fulfilled= 10 Category B Trees Cash equivalent due to fulfill tree mitigation = $5,000 ADDRESS: 1413 VINCE TRAIL Tree Preservation Plan FOR ETERNITY HOMES LLC ,- EAGAN FORESTRY DIVISION REVIEWED BY: A.SCHNAIBLE DATE: BoN VINCE TRAIL __--p CONCRETE CURB 4 GUTTER N 5ENCnMARK: A=8°43'05" 893.4 ASS_ ✓UQ .6 896.2 TNtt=594.60 yY� L=20.54 69a.4 I 895d.6 S89°✓ G 71 98.6 _ 89 .3 8957 ^CURS ^ I A97.ti1 � x 8%.9 �' \ STOP ( LOT AREA = 16,309 SO. FT. HOUSE AREA = 2,142 $Q. FT 5 898.6 x 898.8I 897 5 / I I 0 � 902.9 i I 8 x x 903.4 MAX x 899.5 � 7 I�® � SETBACK INFORMATION: I m o , In FRONT=30' ( N " ``"E PROP05ED ,, / RETAINING SIDE YARD= 10' (HOUSE) ti ~ 9 ,X x 90 2AL� � 1 R I � • x 900.6 `ti,° ' SIDE YARD= 5'(GARAGE) rn REAR YARD = 15' (HOUSE) W REAR YARD =5'(SHED) 04 N x 902.2 PROPO EI / e I LU s p DRIVEWAY I c`) ° I - 9.G5ro 1 a O C) 902 ., M Z x 903.1 904.1 i I CO XI.8 Z p lu I I ,,5 T 4 +� 5.6 v p 0 I �J 0 903.7 20.0- 906.Ix J z a m x PORGh=906.2 4 904,6 x 907.2 a nz.o o GARAGE Oa I m ; i,O 1 5.0 NOTE:ADD 3 EXTRA f i3 O 5TEP5 BETWEEN THE :u 5 n r i fS ND GARAGE y f0820 8904.4 l '�! 6a N89055'38"W 5 ni j I .I 8.7908.9 I x904.7 O� T26 4.00 Ilz�, x 905.8 a �.o -�, PROPOSED TR S e� %, TREE TABLE 2-STORY s "i, I m yc FB/FLAT 10 TAG, SPECIES. DIAMETER STATUS 1 I � 01 G07WNW0G0i 645TERN 35-" Remove i` � 19.0 4.0` 02 GOTTONWOODL, EASTERN 28-� Remove `� wMi o o wnv 03 GOTTON N 28L� Remove D 13.0 04 B#?W, A4 1#-' Remove x \� j9oG1 $T 913.1 06 MAPLE, SILVER 28" Remove i� \100 + I I %9.8 06 ASH, GREEN 24" Excluded co I %4 �. - T� /� f 07 G134B,4RRLE 06-! Remove N 90 \\_ z_-_ 15 to 08 CDAO w Remove � 09 CR�A54PPLE 06� SaveLO � 10 MULBERRY, RED 12 Save LU 11 MULBERRY, RED 12" Save I i ® 06 x908.2 ® x 909.4 x 911.0 o ( ( � NOTE. TREE TABLE INFORMATION WAS TAKEN FROM O THE TREE PRESERVATION PLAN PREPARED BY O I i Install Tree Protection RENDER FORESTRY CONSULTING DATED 1-20-21 Z I , LOT v1 I fencing at the dripline ,--1BLOCK 1 O 908.3 i T I Z 1 x 911.7 •I' x 913.1 x 9113 I i Move Existing silt fence to q 909.3x ( exclude 2 significant trees 0 I 1 0 I 91a.ox = x 910.9 I x 913.4 .. _ ® DENOTES MAILBOX 0• n T 1 T 10 A DRAINAGE t UTL7YEA9EMNT n - 91 911 O DENOTES IRON PIPE MONUMENT SET 9I2.1 913.5 9 4.5 914.9 915 7 DENOTES FOUND IRON PIPE MONUMENT N89°5620"W 77.00 PE GE 9t5.3 908.7 T DENOTES PROPOSED DRAINAGE DIRECTION NOTE.• ADD 3 EXTRA STEPS BETWEEN THE HOUSE AND 0 DENOTES SERVICE LOCATION GARAGE = 2,2 El DENOTES WOOD HUB PROPOSED TOP OF WALL ELEV. = 905.2 0MA DENOTES EXISTING ELEVATION PROPOSED GARAGE FLOOR ELEV. = 903.0 ® DENOTES PROPOSED ELEVATION PROPOSED BASEMENT FLOOR ELEV. = 897.5 �Op-- DENOTES EXISTING CONTOUR PROPERTY DESCRIPTION DENOTES DECIDUOUS TREE LOT 1,BLOCK 1,KENNERICK THIRD ADDITION, CITY OF EAGAN,DAKOTA COUNTY,MINNESOTA. DENOTES EVERGREEN TREE Bohlen I HEREBY CERTIFY THAT THIS SURVEY WAS PREPARED BY ME OR DENOTES BITUMINOUS SURFACE UNDER MY DIRECT SUPERVISION AND THAT I AM A DULY LICENSED Surveying & Associates LAND SURVEYOR UNDER THE LAWS OF THE STATE OF MINNESOTA. 31432 Foliage Avenue 1682 CIM Road E. DENOTES CONCRETE SURFACE Northfield,MN 55057 Burnsville,MN 55337 Phone:(507)645.7768 B A Phone:(952)895-9212 DATE: 8-31-2022 tomeara@bohlensurveying.com Fax:(952)8959269 THOMAS J.OWEARA,LAND SURVEYOR DENOTES GRAVEL SURFACE MINNESOTA LICENSE NO.46167 F:IProjectslEagan\kcnnerick-third-additionldwglLIBI-cert-8-24-22.dwg 8/24/2022 7:18:12 AM CDT ADDRESS: 1413 VINCE TRAIL CERTIFICATE OF SURVEY REVIEWED FOR FOR CODE COMPLIANCE 3:1 MAX. SLOPES OR RETAINING WALL REQUIRED ETERNITY HOMES LLC x 891.8 EAGAN INSTALL PERIMETER - Dave 2 221:27:12P CONTROL estermeyer 09/09/2022 1:27:12 PM ENGINEERING 89 N V I N C E TRAIL NOTE. ALL BUILDING R 135.00 CONCRETE CURB b GUTTER N DIMENSIONS ARE SHOWN TO BENCHMARK: _iir n 893.4 8�5 x99 p Qq6 RQ5.6 996.2 OUTSIDE OF FOUNDATION -$ 43 05 WALL TNH=894.60VIZI L=20.54 `� I 994.4 1 x95., S89033-2 2 71 `i f 99.6 89>.3 95.7n I 1 -897F - CURB X 896.9 STOP LOT AREA = 16,309 SO. FT. HOUSE AREA = 2,142 SO. FT. ou x x9x x " 5 _902.9 111 x X 903.4 c�- 0 c� PROPOSED RETAINING � "URNSVILJLE a WALL Healing& Ait Conditiurtinjr, /nC. � x 905.2 �x P O N _O Table 501.4.1 2I W Procedure to Determine Makeup Air Quantity for Exhaust Appliances in Dwelling Units 5.9 i C,) �t rn MULTIPLE � ONE OR MULTIPLE ONE OR MULTIPLE ONE APPLIANCES THAT I a POWER VENT OR FAN-ASSISTED ATMOSPHERICALLY ARE O DIRECT VENT APPLIANCES AND VENTED GAS OR OIL ATMOSPHERICALLY I z APPLIANCES OR NO POWER VENT OR APPLIANCE OR ONE VENTED GAS OR OIL COMBUSTION DIRECT VENT SOLID FUEL APPLIANCES OR SOLID APPLIANCESA APPLIANCESB APPLIANCEc FUEL APPLIANCESD I 1.Use Appropriate Column to Estimate House Infiltration a pressure factor X 907.2 (cfm/sf) 0.15 0.09 0.06 b)conditioned floor 4344 0.03 I area(sf) (including unfinished basements) Estimated House 651.6 909.7 Infiltration(cfm): lax lb] 908.9 �f 2. Exhaust Capacity s a)Clothes dryer 135 c 135 135 '1 b)80%of largest 64 135 0 exhaust rating(cfm) (not applicable if recirculating system or if powered makeup air is electrically interlocked and matched to exhaust c) 80%of next 64 largest 9131 exhaust rating 909.8 (cfm): (not applicable if recirculating system or if powered makeup air is electrically interlocked and matched to exhaust I L Total Exhaust Capacity 263 ce) (cfm): L"?00 I [2a+2b+2c] I � 3. Makeup Air Requirement x 911.0 547)TotalExhaust 263 I P > Capacity (from above) I �_ b) Estimatd 651.6 House Infiltration I O (from above) Z Makeup Air -388.6 I x 913.1 Quality(cfm): [3a-3b] (if value is negative,no makeup air is needed 4. For Makeup Air opening Sizing,refer to Table 501.4.2 Ox 5 A.Use this column if there are other than fan-assisted or atmospherically venter gas or oil appliances or if there are no combustion appliances. D B.Use this column if there is one fan-assisted appliance per venting system.Other atmospherically vented appliances may also be included. 91G'1 C.Use this column if there is one atmospherically vented(other than fan-assisted)gas or oil appliance per venting system or one solid fuel appliance. 4.9 D.Use this column if there are multiple atmospherically vented gas or oil appliances using a common vent or if there are atmospherically vented gas or oil *_' 915 7 � 915.--�3 rix. 9ETWEEN THE HOUSE AND _V. = 905.2 LEV. = 903.0 ELEV. = 897.5 SCRIPTION DENOTES DECIDUOUS TREE LOT 1,BLOCK 1,KENNERICK THIRD ADDITION, CITY OF EAGAN,DAKOTA COUNTY,MINNESOTA. DENOTES EVERGREEN TREE Bohlen I HEREBY CERTIFY THAT THIS SURVEY WAS PREPARED BY ME OR DENOTES BITUMINOUS SURFACE UNDER MY DIRECT SUPERVISION AND THAT I AM A DULY LICENSED Surveying & Associates LAND SURVEYOR UNDER THE LAWS OF THE STATE OF MINNESOTA. 31432 Foliage Avenue 1682 Cliff Road E. DENOTES CONCRETE SURFACE Northfield,MN 55057 Burnsville,MN 55337 Trkl I Z a DATE: 8-31-2022 ' I W't"'o Phone:(507)645-7768 Phone:(952)895.9212 THOMAS J.O'MEARA,LAND SURVEYOR tomeara@bohlensurveying.com Fax:(952)895-9259 DENOTES GRAVEL SURFACE MINNESOTA LICENSE NO.46167 F:\Projects\Eagan\kennerick-third-addition\dwg\L1B1-cert-8-24-22.dwg 8/24/2022 7:18:12 AM CDT Rhvac-Residential&Light Commercial HVAC Loads v '—' Elite Software Development,Inc. Burnsville Heating&A/C Inc The Cape Cod With Sport Ct LBurnsville,MN 55337 a e2 Project Report General Project Information Project Title: The Cape Cod With Sport Ct Designed By: Alan Dobson Project Date: Thursday, October 20, 2022 j Project Comment: Client Name: Eternity Homes j Company Name: Burnsville Heating&A/C Inc. Company Representative: Alan Dobson j Company Address: 3451w Burnsville Pkwy, Suite 120 Company City: Burnsville,MN 55337 Company Phone: 952-894-0005 I Company Fax: 952-894-0925 Company Comment: I Design Data --— - - —— ———-— I Reference City: Minneapolis, Minnesota Building Orientation: Front door faces North Daily Temperature Range: Medium Latitude: 44 Degrees Elevation: 834 ft. Altitude Factor: 0.970 Elevation Sensible Adj. Factor: 1.000 Elevation Total Adj. Factor: 1.000 Elevation Heating Adj. Factor: 1.000 Elevation Heating Adj. Factor: 1.000 Outdoor Outdoor Outdoor Indoor Indoor Grains Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference Winter: -15 -15.33 80% n/a 72 n/a Summer: 88 72 47% 50% 75 29 i Check Figures Total Building Supply CFM. 947 CFM Per Square ft.. 0.210 Square ft. of Room Area: 4,506 Square ft. Per Ton: 2,008 i Volume(ft') of Cond. Space: 41,428 Building Loads Total Heating Require Includin9 Ventilation Air: 69,867 Btuh 69.867 MBH Total Sensible Gain. 21,094 Btuh 78 % Total Latent Gain: 5,835 Btuh 22 % Total Cooling Required Including Ventilation Air: 26,929 Btuh 2.24 Tons(Based On Sensible+ Latent) Notes - - - -- - - ---- - >- - -___ _._-__ -_.:-_-_-- - Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. I All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. I I I i I I i f C:\...\NJJ The Cape Cod w sport ct W.rhv Thursday. October 20. 2022. 11:41 PM Rhvac-Residential&Light Commercial HVAC Loads - J Elite Software Development,Inc.I Burnsville Heating&A/C Inc The Cape Cod With Sport Ct `Burnsville,MN 55337 Page10 .; Total Building Summary Loads Component - Area Sen Y Lat SenTotal} Description- Quan LossGain Gain Gain 1 -- - -- - - - - --- -- - - EH: Glazing-EH , ground reflectance=0.23, u-value 200.5 4,881 0 2,288 2,288 0.28, SHGC 0.22 EH: Glazing-EH , ground reflectance= 0.23, u-value 211.5 5,149 0 3,339 3,339 I 0.28, SHGC 0.22 EH: Glazing-EH , ground reflectance=0.23, u-value 36 877 0 943 943 0.28, SHGC 0.22 hbt: Door- 20.4 266 0 73 73 hbt: Door- 19 232 0 64 64 f 12F-Osw: Wall-Frame, R-21 insulation in 2 x 6 stud 4388.3 24,814 0 3,793 3,793 cavity, no board insulation, siding finish, wood studs 15BO-15sf-8: Wall-Basement, , R-15 board insulation to 1095 4,261 0 89 89 floor, no interior finish, 8'floor depth R-49: Roof/Ceiling- 667.9 1,162 0 641 641 R49-ad: Roof/Ceiling- 1112 1,935 0 1,068 1,068 19A-30p: Floor-Over enclosed unconditioned crawl 182 452 0 68 68 ; space, No insulation on,exposed walls, sealed or vented space, passive, R-30 blanket 1 20P-30: Floor-Over open crawl space or garage, Passive, 100.8 307 0 28 28 I I� R-30 blanket insulation any cover 21A-20-v: Floor-Basement, Concrete slab, any thickness, 1467.9 3,448 0 0 0 I 2 or more feet below grade, no insulation below floor, vinyl covering, shortest side of floor slab is 20'wide j Subtotals for structure: 47,784 0 12,394 12,394 j People: 6 1,380 1,800 3,180 I Equipment. 400 3,600 4,000 1 Lighting: 0 0 0 Ductwork: 4,742 347 2,193 2,540 j Infiltration: Winter CFM: 116, Summer CFM: 0 10,744 0 0 0 Ventilation: Winter CFM: 192, Summer CFM: 192 6,596 3,708 879 4,587 AED Excursion: 0 0 227 227 Total Building Load Totals: 69,867 5,835 21,094 26,929 _ I -Checkures i Total Building Supply CFM. 947 CFM Per Square ft.: 0.210 Square ft. of Room Area: 4,506 Square ft. Per Ton: 2,008 Volume(ft')of Cond. Space: 41,428 ,:Building Loads Total Heating Required Including Ventilation Air: 69,867 Btuh 69.867 MBH Total Sensible Gain: 21,094 Btuh 78 % Total Latent Gain: 5,835 Btuh 22 % Total Cooling Required Including Ventilation Air: 26,929 Btuh 2.24 Tons(Based On Sensible + Latent) 'Notes------- ---= ----- ----- ---------- ------------- --- ---- ---- --- ---- - ----� i Rhvac is an ACCA approved Manual J and Manual D computer program. iCalculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. I I I I i I C:\...\NJJ The Cape Cod w sport ct W.rhv Thursday, October 20, 2022, 11:41 PM rRhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. Burnsville Heating&A/C Inc The Cape Cod With Sport Ct, I Burnsville,MN'55337 System 1 Main Floor Summary Loads Component Area Sen Lat Sen Total I Description Quan Loss Gain ' Gain Gain EH: Glazing-EH , ground reflectance=0.23, u-value 200.5 4,881 0 2,288 2,288 0.28, SHGC 0.22 EH: Glazing-EH , ground reflectance=0.23, u-value 211.5 5,149 0 3,339 3,339 0.28, SHGC 0.22 EH: Glazing-EH , ground reflectance=0.23, u-value 36 877 0 943 943 0.28, SHGC 0.22 j hbt: Door- 20.4 266 0 73 73 ! hbt-. Door- 19 232 0 64 64 12F-Osw: Wall-Frame, R-21 insulation in 2 x 6 stud 4388.3 24,814 0 3,793 3,793 cavity, no board insulation, siding finish, wood studs 15BO-15sf-8: Wall-Basement, , R-15 board insulation to 1095 4,261 0 89 89 , floor, no interior finish, 8'floor depth R-49: Roof/Ceiling- 667.9 1,162 0 641 641 I R-49-ad: Roof/Ceiling- 1112 1,935 0 1,068 1,068 19A-30p: Floor-Over enclosed unconditioned crawl 182 452 0 68 68 1 space, No insulation on exposed walls, sealed or vented space, passive, R-30 blanket 120P-30: Floor-Over open crawl space or garage, Passive, 100.8 307 0 28 28 R-30 blanket insulation, any cover 21A-20-v: Floor-Basement, Concrete slab, any thickness, 1467.9 3,448 0 0 0 2 or more feet below grade, no insulation below floor, vinyl covering, shortest side of floor slab is 20'wide Subtotals for structure: 47,784 0 12,394 12,394 j People: 6 1,380 1,800 3,180 Equipment: 400 3,600 4,000 i Lighting: 0 0 0 1 Ductwork: 4,742 347 2,193 2,540 ! Infiltration: Winter CFM: 116, Summer CFM: 0 10,744 0 0 O Ventilation: Winter CFM: 192, Summer CFM: 192 6,596 3,708 879 4,587 I 1 AED Excursion: 0 0 227 227 System 1 Main Floor Load Totals: 69,867 5,835 21,094 26,929 - - --- - --------- --- -- Check F_ res Supply CFM: 947 CFM Per Square ft.: 0.210 Square ft. of Room Area: 4,506 Square ft. Per Ton: 2,008 Volume(ft')of Cond. Space 41,428 - - -- -- ---- - -- - -- Total Heating Required Including Ventilation Air: 69,867 Btuh 69.867 MBH ( 9 q 9 Total Sensible Gain: 21,094 Btuh 78 % 0 Total Latent Gain: 5,835 Btuh 22 /o � Total Cooling Required Including Ventilation Air: 26,929 Btuh 2.24 Tons(Based On Sensible+ Latent) j R h v a c is an ACCA approved M a n-_u a I J and M a n- a I U c o_­m-p--u-t-_e r program. ! Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. j j All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. ! I I 1 C:\...\NJJ The Cape Cod w sport ct W.rhv Thursday. October 20. 2022. 11:41 PM Rhvac Residential 8-Light Commercial HVAC Loads _ --� Elite Software Development,Inc. i Burnsville Heating&A/C Inc The Cape Cod With Sport Ct Burnsville,MN 55337 —--------- _.------ System 9, Zone_1 Summary Loads (Peak Load Procedure for Rooms) Component Area Sen Lat Sen Total _Description-- -- - - - Quan Loss - Gain Gain Gain) EH: Glazing-EH , ground reflectance=0.23, u-value 94 2,288 0 1,074 1,074 0.28, SHGC 0.22 EH: Glazing-EH , ground reflectance=0.23, u-value 131 3,189 0 2,296 2,296 0.28, SHGC 0.22 EH: Glazing-EH , ground reflectance =0.23, u-value 12 292 0 314 314 0.28, SHGC 0.22 hbt: Door- 20.4 266 0 73 73 hbt: Door- 19 232 0 64 64 12F-Osw: Wall-Frame, R-21 insulation in 2 x 6 stud 1448.7 8,193 0 1,252 1,252 cavity, no board insulation, siding finish, wood studs R-49: Roof/Ceiling- 177.6 309 0 170 170 j i Subtotals for structure: 14,769 0 7,088 7,088 People: 0 0 0 0 ! Equipment: 0 2,400 2,400 Lighting: 0 0 0 I Ductwork: 1,494 0 972 972 I Infiltration: Winter CFM: 40, Summer CFM: 0 3,670 0 0 0 j System 1, Zone 1 Load Totals: 19,933 0 10,561 10,561 i i Check Fic,�ures Supply CFM- 495 CFM Per Square ft.. 0.345 Square ft. of Room Area: 1,435 Square ft. Per Ton: 1,631 j Volume (ft')of Cond. Space: 14,665 Zone Loads Total Heating Required: 19,933 Btuh 19.933 MBH Total Sensible Gain: 10,561 Btuh 100 % Total Latent Gain: 0 Btuh 0 % Total Cooling Required: 10,561 Btuh 0.88 Tons(Based On Sensible+ Latent) -Rhvac is an ACCA approved Manual J and Manual D computer program. iCalculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. ! j I i I ! I i I i i I i i II I i i I I I C:\...\NJJ The Cape Cod w sport ct W.rhv Thursday. October 20, 2022, 11:41 PM Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. l Burnsville Heating&A/C Inc dW The Cape Cod With Sport Ct I Burnsville,MN 55337 Page 17� System 1, Zone 2 Summary Loads (Peak Load Procedure for Rooms) _ Component Area Sen Lat Sen Total Descrption Q_uan Loss Gain Gain Gain; EH: Glazing-EH , ground reflectance=0.23, u-value 56 1,363 0 659 659 0.28, SHGC 0.22 EH: Glazing-EH , ground reflectance=0.23, u-value 24 585 0 629 629 0.28, SHGC 0.22 EH: Glazing-EH , ground reflectance=0.23, u-value 89 2,167 0 940 940 0.28, SHGC 0.22 12F-Osw: Wall-Frame, R-21 insulation in 2 x 6 stud 1164.6 6,585 0 1,007 1,007 cavity, no board insulation, siding finish, wood studs j R-49: Roof/Ceiling- 490.3 853 0 471 471 R-49-ad: Roof/Ceiling- 1112 1,935 0 1,068 1,068 19A-30p: Floor-Over enclosed unconditioned crawl 182 452 0 68 68 space, No insulation on exposed walls, sealed or j vented space, passive, R-30 blanket 20P-30: Floor-Over open crawl space or garage, Passive, 100.8 307 0 28 28 R-30 blanket insulation, any cover Subtotals for structure: 14,247 0 5,923 5,923 People: 5 1,150 1,500 2,650 Equipment: 400 0 400 i Lighting: 0 0 0 Ductwork: 1,384 0 761 761 Infiltration: Winter CFM: 31, Summer CFM: 0 2,836 0 0 0 System 1, Zone 2 Load Totals: 18,467 1,550 8,262 9,812 Check F1 ures` -- j Supply CFM: 387 CFM Per Square ft.: 0.241 Square ft. of Room Area: 1,603 Square ft. Per Ton: 1,960 Volume(W)of Cond. Space: 12,818 Zone Loads -- Total Heating Required: 18,467 Btuh 18.467 MBH Total Sensible Gain: 8,262 Btuh 84 % j Total Latent Gain: 1,550 Btuh 16 % Total Cooling Required: 9,812 Btuh 0.82 Tons(Based On Sensible+Latent) i Notes j Rhvac is an ACCA approved Manual J and Manual D computer program. j Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. i All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. i i I I I i C:\...\NJJ The Caoe Cod w snort ct W.rhv Thursday. October 20, 2022, 11:41 PM Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. Burnsville Heating&A/C Inc The Cape Cod With Sport Ct I Burnsville,MN 55337 Page 18 System 1, Zone 3 Summary Loads (Peak Load Procedure for Rooms) Component Area Sen Lat Sen Total' Descri ting -g _ _ - - - _ -. — - p Quan Loss Gain Gain Gain , EH: Glazin EH , round reflectance=0.23, u-value 17.5 426 0 274 274 0.28, SHGC 0.22 EH: Glazing-EH , ground reflectance=0.23, u-value 24.5 597 0 384 384 0.28, SHGC 0.22 12F-Osw: Wall-Frame, R-21 insulation in 2 x 6 stud 1775 10,036 0 1,534 1,534 cavity, no board insulation, siding finish, wood studs 15BO-15sf-8: Wall-Basement, , R-15 board insulation to 1095 4,261 0 89 89 floor, no interior finish, 8'floor depth 21A-20-v: Floor-Basement, Concrete slab, any thickness, 1467.9 3,448 0 0 0 2 or more feet below grade, no insulation below floor, covering,vinyl y g, sho rtest side of floor slab is 20'wide , Subtotals for structure: 18,768 0 2,996 2,996 People: 1 230 300 530 Equipment: 0 1,200 1,200 Lighting: 0 0 0 Ductwork: 1,864 0 461 461 Infiltration: Winter CFM: 46, Summer CFM: 0 4,238 0 0 0 System 1, Zone 3 Load Totals: 24,870 230 5,004 5,234 Check Figures _— --- ------ ---- -------- _ -, - ---- ------------- --_ - - ---- - - --- ---- - -. ------- Supply CFM: 234 - CFM Per Square ft.. 0.160 Square ft. of Room Area: 1,468 Square ft. Per Ton: 3,365 Volume(ft')of Cond. Space: 13,945 Zone Loads - —-- -- --- ---- --- -. ---- -- Total Heating Required: 24,870 Btuh 24.870 MBH Total Sensible Gain: 5,004 Btuh 96 % Total Latent Gain: 230 Btuh 4 % I Total Cooling Required: 5,234 Btuh 0.44 Tons(Based On Sensible + Latent) Notes Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. ' I i I 1 II f C:\ \NJJ The Cape Cod w sport ct W.rhv Thurcriau ortnhar')n )m,) 11•A1 one Rhvac-'Residential&Light Commercial HVAC Loads Elite Software Development,Inc. j Burnsville Heating&A/C Inc The Cape Cod With Sport Ct Burnsville,MN 55337 Page 41 ' Detailed Room Loads Room 17 - Basement (Peak Fenestration Gain Procedure) - Room is in zone 3, which peaks at 2 pm Calculation Mode: Htg. &clg. Occurrences: 1 Room Length: 38.6 ft. System Number: 1 Room Width: 38.0 ft. Zone Number: 3 Area: 1,468.0 sq.ft. Supply Air: 234 CFM Ceiling Height: 9.5 ft. Supply Air Changes: 1.0 AC/hr Volume: 13,945.0 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 1 Actual Winter Vent.: 75 CFM Runout Air: 234 CFM Percent of Supply.: 32 % Runout Duct Size: 9 in. Actual Summer Vent.: 40 CFM Runout Air Velocity: 531 ft./min. Percent of Supply: 17 % Runout Air Velocity: 531 ft./min. Actual Winter Infil.: 46 CFM Actual Loss: 0.101 in.wg./100 ft. Actual Summer Infil.: 0 CFM -- - --9---- -- - --- Description _ Qu ntity Vale HTM Loss HTM Gain Gain S Wall 12F Osw 38 X 9.5 319 0.065 5.7 1,804 0.9 0 276 N-Wall-15BO-15sf-8 38 X 9.5 361 0.042 3.9 1,405 0.1 0 29 W-Wall-1 5BO-1 5sf-8 38.6 X 9.5 367 0.042 3.9 1,428 0.1 0 30 E -Wall-15BO-15sf-8 38.6 X 9.5 367 0.042 3.9 1,428 0.1 0 30 S -Wall-12F-Osw 38 X 9.5 361 0.065 5.7 2,041 0.9 0 312 N -Wall-12F-Osw 38 X 9.5 361 0.065 5.7 2,041 0.9 0 312 W-Wall-1 2 F-Osw 38.6 X 9.5 367 0.065 5.7 2,075 0.9 0 317 j E-Wall-12F-Osw 38.6 X 9.5 367 0.065 5.7 2,075 0.9 0 317 j S-GIs-EH shgc-0.22 0%S 17.5 0.280 24.4 426 32.7 0 572 S-GIs-EH shgc-0.22 0%S 24.5 0.280 24.4 597 32.7 0 801 Floor-21A-20 38 X 38.6 1467.9 0.027 2.3 3,448 0.0 0 0 j Subtotals for Structure: 18,768 0 2,996 Infil.: Win.: 45.6, Sum.. 0.0 1,992 2.127 4,238 0.000 0 0 I Ductwork: 1,864 461 AED Excursion: 48 j People: 230 lat/per, 300 sen/per: 1 230 300 Equipment: 0 1,200 Room Totals: 24,870 230 5,004 j I I j I I i I I I I I I i I i I C:\...\NJJ The Cape Cod w sport ct W.rhv Thnrcrlav r)rtnhar 9n )m,) 11•A 1 onn Rhvac-Residential 8 Light Commercial HVAC Loads Elite Software DevelopmenInc. Burnsville Heating&A/C Inc The Cape Cod With Sport Ct� Burnsville,MN 55337 Page 46 System I-Room Load Summary -- - -- --- _ _ -_ ---- -_; Htg Min Run Run CI9 CI9 Min Act Room Area Sens Htg Duct Duct Sens Lat Clg Sys No Name SF Btuh CFM Size Vel Btuh Btuh CFM CFM' ---Zone 1--- - 1 Foyer 84 2,477 33 1-3 559 585 0 27 27 2 Den 154 3,303 44 1-5 379 1,102 0 52 52 3 Stairs 173 905 12 1-4 232 432 0 20 20 4 Great Room 299 4,390 59 1-6 528 2,214 0 104 104 5 Dining 131 3,701 50 1-7 459 2,619 0 123 123 6 Kitchen 329 1,218 16 1-7 493 2,811 0 132 132 7 Mud Room 219 3,111 42 1-3 375 393 0 18 18 8 Tech Center 46 828 11 1-3 387 405 0 19 19 Zone 1 subtotal 1,435 19,933 267 10,561 0 495 495 ---Zone 2--- 9 Loft 257 3,821 51 1-6 527 2,207 230 103 103 10 Bedroom 3 198 2,703 36 1-4 678 1,262 230 59 59 11 J & J Bath 133 781 10 1-2 435 203 0 9 9 12 Bedroom 2 187 1,496 20 1-4 599 1,116 230 52 52 13 Master Bedroom 292 3,337 45 1-5 633 1,841 460 86 86 j 14 Master Bath 281 3,156 42 1-3 674 706 0 33 33 15 Bedroom 4 154 2,653 36 1-4 423 788 0 37 37 16 Laundry 101 521 7 1-2 299 139 400 7 7 Zone 2 subtotal 1,603 18,467 247 8,262 1,550 387 387 ---Zone 3--- 17 Basement 1,468 24,870 333 1-9 531 5,004 230 234 234 i Zone 3 subtotal 1,468 24,870 333 5,004 230 234 234 Ventilation 6,596 879 3,708 Duct Latent 347 l System 1 total 4,506 69,867 847 21,094 5,835 947 947 I System 1 Main Trunk Size: 11x16 in. Velocity: 775 ft./min Loss per 100 ft.: 0.093 in.wg I Note: Since the system is multizone, the Peak Fenestration Gain Procedure was used to determine glass sensible gains j at the room and zone levels, so the sums of the zone sensible gains and airflows for cooling shown above are not intended j to equal the totals at the system level. Room and zone sensible gains and cooling CFM values are for the hour in which the glass sensible gain for the zone is at its peak. Sensible gains at the system level are based on the"Average Load l Procedure+ Excursion"method. i Coaling System.Summ> Cooling Sensible/Latent Sensible Latent Total .._Tons-- --- Split---- _- Btuh -_..__ - Btuh Btuh ; Net Required: 2.24 78%/22% 21,094 5,835 26,929 ; I I l I C:\...\NJJ The Cape Cod w sport ct W.rhv Thursday. October 20. 2022. 11.41 PM New Construction Energy Code Compliance Certificate Per R401.3 Certificate.A building certificate shall be posted on or in the electrical distribution 7ertificate Posted panel. 10/21/2022 Place your Mailing Address of the Dwelling or Dwelling Unit City logo here 1413 Vince Trail Eagan Name of Residential Contractor MN License Number Eternity Homes LLC IBC638704 THERMAL ENVELOPE RADON CONTROL SYSTEM Type:Check All That Apply X Passive(No Fan) Active(With/an and monometer or other yc system monitoring device) C N Location(or future location)of Fan: T U C d 41 O a 0 3 (� O 'O @ a m Q m CO a) �-0oT a >�', Z m m U O� @ tj Insulation Location — m o m m E E _ o N o o o °i °' i.- z I u- LL u- u- E E Other Please Describe Here Below Entire Slab Foundation Wall 10 X Perimeter of Slab on Grade 15 X Rim Joist(1st Floor) 21 X Rim Joist(2nd Floor+) 21 X Wall 20 X Ceiling,flat 49 X Ceiling,vaulted 49 X X Bay Windows or cantilevered areas 30 X Floors over unconditioned area 30 X Describe other insulated areas Building envelope airtightness: Duct system airtightness: Windows&Doors Heating or Cooling Ducts Outside Conditioned Spaces Average LI-Factor(excludes skylights and one door)U: 0.28 XNot applicable,all ducts located in conditioned space Solar Heat Gain Coefficient(SHGC): 10.22 R-value R-8 in garage area MECHANICAL SYSTEMS Make-up Air Select a Type Appliances Heating System Domestic WaterCoolingSystem Heater X Not required per mech.code Fuel Type Gas Gas R-410A Passive Manufacturer Daikin A.O Smith Daikin Powered Interlocked with exhaust device. Model DM92SNO803B DX13SNO36 Describe: Input in 80,000 Capacity in 50 Output 2.5 Other,describe: Rating or Size BTUS: Gallons: in Tons: AFUE or 92% SEER 13 Location of duct or system: Efficiency HSPF% /EER Heating Loss Heating Gain Cooling Load Residential Load Calculation 69,867 21,094 26,969 Cfm's "round duct OR MECHANICAL VENTILATION SYSTEM "metal duct Describe any additional or combined heating or cooling systems if installed:(e.g.two furnaces or air Combustion Air Select a Type source heat pump with gas back-up furnace): Not required per mech.code Select Type 6" Passive X Heat Recover Ventilator(HRV) Capacity in cfms: Low: 82 High: 1 190 Other,describe: Energy Recover Ventilator(ERV)Capacity in cfms: Low: I 11-figh: I Location of duct or system: Balanced Ventilation capacity in cfms: Location of fan(s),describe: I Cfm's Capacity continuous ventilation rate in cfms: "round duct OR Total ventilation(intermittent+continuous)rate in cfms: "metal duct Builders Associaton of Minnesota version 101014 ADDRESS: 1413 VINCE TRAIL CERTIFICATE OF SURVEY REVIEWED FOR FOR CODE COMPLIANCE ES OR ERETAINHNG WAL1 MAX. L PREQUIRED ETERNITY HOMES LLC 89 .8 EAGAN INSTALL PERIMETERCENTERLINE - - - Dave Westermayer CONTROL 09/09/2022 1:27:12 PM ENGINEERING V I N C E TRAIL 9? � NOTE. ALL BUILDING CONCRETE CURB 6 GUTTER N DIMENSIONS ARE SHOWN TO �S,OO OUTSIDE OF FOUNDATION BENCHMARK. - ° r ° 893.4 - "" "'2 : 895.0 Q 6 825.6 896.2 WALL TNH=894.60, v L= �+p 894.4 - i --- 896:6-JUO071. .iI 98.6 95. '895.i" 4 I 897.6 STOP LOT AREA = 16,309 SQ. FT. I HOUSE AREA = 2,142 SQ. FT. 5 898.6 x 98.8 I902 9 9 .i CaOC' I r 898 ty x 903.4 899.8 /x 899.5 / 90 7 r o/ I 898. SETBACK INFORMATION: o I a r 899, FROP05ED I __�_ ` - K LINE FRONT= 30' _, �/ I _ - / o- RETAINING a WALL SIDE YARD = 10' HOUSE ti ~ �'9 s R1 "� 9029 �� 2905.2 (HOUSE) 0� I x 900., 009 1- -11- • SIDE YARD = 5' (GARAGE) �- 900. N a rn I REAR YARD = 15' (HOUSE) W REAR YARD = 5' (SHED) c� „• �_ ��, N M-2 PROP05ED 1 s.21 W d' o ( JRIVEWPY I J 0 i O i= I E) I nI co Z m x 90921 9OX�1 I o0`/ m rn (fl Ir , I" O f i X904:8 I z TR;3 I T�R 4 . 903. A.05.6 Ln Oz p 20.0-/ 12.0 /N / ; I 903.7 / 90F.1 x, Z ,n x PORCh1=906.2 pro 904.6 x 907.2 O I 12.0 O / oEll �I r / m GARAGES o_O �) 8.0 tJOTE:ADD 3 EXTRA / o p�„ I :1) -; /STEPS BETWEEN THE / p 1" = not `I 5 J HOU5E AND GAPAGE I / C\1 9 h - G 90 n I / /� T 3�f' 904.4 h gi o / t 995.6 O 7 5 > i 7.0 ) 1.1 908.7 N89055'38"W y.,- a I3° / J 90 .t 1 9 7 °w 908.9 TR 6 4.00 x 904.7/ x 90,5.8 p f PROPOSED/'TR 8 ° 2-STORY s n �c TREE TABLE FB/PLAIT °��� �o� �pc j TA G# SPEC/ES. DIAMETER CONDITION 01 COTTONWOOD, EASTERN 35" GOOD I 9.0 / 14.0 02 COTTONWOOD, EASTERN 28" GOOD " 4'11_1W/w o 0 0 Wiw oa 907. . 03 COTTONWOOD, EASTERN 28" GOOD 3. O 6� I 13.0 9 04 BIRCH, PAPER 14" FAIR xli I _ 906.1 9 7 904. �+ i I 913.1 05 MAPLE, SILVER 28" GOOD -�. I 909.8 (/ 06 ASH, GREEN 24" GOOD cfl 90a �� CoQ I 07 CRABAPPLE 06" FAIR 08 CRABAPPLE 09" FAIR 1905 y�0 09 CRABAPPLE 06" FAIR O 907. ! 906 - 10 MULBERRY, RED 12" GOOD W 00; 11 MULBERRY, RED 12" FAIR I qp8 I d- x908.2 08. - 909 x 909.4 p�I x 911.0 Q I 409- NOTE.- TREE TABLE INFORMATION WAS TAKEN FROM C) ap THE TREE PRESERVATION PLAN PREPARED BY Z I I - '' ,OT 1 y REHDER FORESTRY CONSULTING DATED 1-20-21 BLOCK- -4- I o ° 908.3I I I TR.9 I/ O _"�1� z x 911.7 _ / I � -'"x913.1 / I x 911.3 I I t /1 I q� 0 909.3x I � -T 914.0x-- z I. I x/910.9 / I / x 913.4 , 51 � 5 _/x 912.0 �- -= Q DENOTES MAILBOX qZ9 TR,,11 f TRIO 9�� I N " X-91 1.8 DRAINAGE t UTILITY EASEIYAT `n 914.8 O DENOTES IRON PIPE MONUMENT SET j Xs- 9.12.1 � 9t h/ 914.5 914.9/ 915.7 DENOTES FOUND IRON PIPE MONUMENT 9io "" N89056'20"W 77.00 FENCE 915.3 908.7 �- DENOTES PROPOSED DRAINAGE DIRECTION NOTE.• ADD 3 EXTRA STEPS BETWEEN THE HOUSE AND DENOTES SERVICE LOCATION GARAGE = 2.2 E] DENOTES WOOD HUB PROPOSED TOP OF WALL ELEV. = 905.2 000.0 DENOTES EXISTING ELEVATION PROPOSED GARAGE FLOOR ELEV. = 903.0 PROPOSED BASEMENT FLOOR ELEV. = 897.5 I=I DENOTES PROPOSED ELEVATION bop- DENOTES EXISTING CONTOUR PROPERTY DESCRIPTION DENOTES DECIDUOUS TREE LOT 1,BLOCK 1,KENNERICK THIRD ADDITION, CITY OF EAGAN,DAKOTA COUNTY,MINNESOTA. DENOTES EVERGREEN TREE Bohlen I HEREBY CERTIFY THAT THIS SURVEY WAS PREPARED BY ME OR DENOTES BITUMINOUS SURFACE UNDER MY DIRECT SUPERVISION AND THAT I AM A DULY LICENSED Surveying & Associates LAND SURVEYOR UNDER THE LAWS OF THE STATE OF MINNESOTA. „ 31432 Foliage Avenue 1682 Cliff Road E. DENOTES CONCRETE SURFACE Northfield,MN 55057 Burnsville,MN 55337 DATE: 8-31-2022 T6 v6Q T OvI J __W Phone:(507)645-7768 B A Phone:(952)895.9212 tomeara@bohlensurveying.com Fax:(952)895-9259 THOMAS J.O'MEARA,LAND SURVEYOR DENOTES GRAVEL SURFACE MINNESOTA LICENSE NO.46167 F:\Projects\Eagan\kennerick-third-addition\dwg\L1B1-ccrt-8-24-22.dwg 8/24/2022 7:18:12 AM CDT