Loading...
EA180073 - Building - Deck - Issued Date 12/12/2022PERMIT City of Eagan Owner: Permit Type: Building 3830 Pilot Knob Rd`.' Eagan, MN 55122 me° �. �.-. • -•-. EAGAN Permit Number: EA180073 (651) 675-5675 111111111111 www.cityofeagan.com * E R 1 8 0 0 7 3 Date Issued: 12/12/2022 Site Address: 518 Chapel Ct Lot: 1 Block: 1 Addition: Cherrywood Knoll PID: 10-17050-01-010 1111111111111111111111111111111111111111 11111M Use: * 10-17050-0 1-0 10* Description: Sub Type: Deck Construction Type: V -B Work Type: New Description: Census Code: 434 - Residential Additions, Alterations Occupancy: IRC -1 Zoning: R-1 Square Feet: 0 Comments: Fee Summary: (BL) Plan Review $86.29 0720.4222 Valuation: 5,400.00 BL - Base Fee $132.75 0801.4085 Surcharge - Based on Valuation $3.00 9001.2195 Total: $222.04 Contractor: - Applicant - Owner: Stumpys Deck Renewal Inc Benjamin & Maija Gust 301 Ruby Drive 518 Chapel Ct West St Paul MN 55118 Eagan MN 55121 (651)208-2371 This permit shall be null and void if work does not start within 180 days of issuance, or if work is suspended for 180 days or more after started. I hereby acknowledge that I have read this application and state that the information is correct and agree to comply with all applicable State of Minnesota Statutes and City of Eagan Ordinances. "A %rr� Applicant/Permitee: Signature ssued B : Signature 3830 PILOT KNOB ROAD I EAGAN, MN 55122-1810 (651) 675-56751 FAX: (651) 675-5694 buildinginsoections(M-cfirofeagan.com ---------------- For Office use 1000 I , I Permit #: � Permit Fee: 22�, b� � I l h Date Received: I � 1 !J L I Staff. 2022 2022 RESIDENTIAL DECK PERMIT APPLICATION Date: 8/1/22 Site Address: 518 Chapel Ct, Eagan, MN 55121 unit #: Benjamin Gust 651 307 3231 E AG A N Resident/ 518 Chapel Ct, Eagan, MN 55121 �� ` �yJ otrd VW 3830 PILOT KNOB ROAD I EAGAN, MN 55122-1810 (651) 675-56751 FAX: (651) 675-5694 buildinginsoections(M-cfirofeagan.com ---------------- For Office use 1000 I , I Permit #: � Permit Fee: 22�, b� � I l h Date Received: I � 1 !J L I Staff. 2022 2022 RESIDENTIAL DECK PERMIT APPLICATION Date: 8/1/22 Site Address: 518 Chapel Ct, Eagan, MN 55121 unit #: You may subscribe to receive an electronic notification from the City of proposed ordinances by signing up for an email update on the City's website at www. citvofeagan.com/subscribe. CALL BEFORE YOU DIG. Contact Gopher State One Call at (651) 4540002 or www.gooherstateonecall.org for protection against underground utility damage. Contact Gopher State One Call 48 hours before you Intend to dig to receive locates of underground utilities. I hereby acknowledge that this information Is complete and accurate; that the work will be In conformance with the ordinances and codes of the City of Eagan; that I understand this is not a permit, but only an application for a permit, and work is not to start without a permit; that the work will be in accordance with the approved plan In the case of work which requires a review and approval of plans. xDennis Pitzl Applicant's Printed Name x 6 -- Applicant's Signature Benjamin Gust 651 307 3231 Name: Phone: Resident/ 518 Chapel Ct, Eagan, MN 55121 �� ` �yJ otrd VW Owner Address / City / Zip: Applicant is: Owner Vf Contractor Owner Email: guStbe@gmail.com Description of work: NEW DECK (Composite Decking/Westbury Aluminum Handrail Type of Work Construction Cost: 201000 Multi -Family Building: (Yes _/ Nom Stumpy's Deck Renewal, Inc Dennis Pitzl Company: contact: Address: 301 Ruby Dr. W. St. Paul Contractor City. State: MN Zip: 55118 Phone: 651-208-237A Email: StumpysDeck@gmail.com License #: BC693531 Lead Certificate #: If the project is exempt from lead certification, please explain why: Not Impactint Exterior Home. Home Build after 83 COMPLETE THIS AREA ONLY IF CONSTRUCTING A NEW BUILDING In the last 12 months, has the City of Fagan Issued a permit for a similar plan based on a master plan? Yes No If yes, date and address of master plan: Licensed Plumber: Phone: Mechanical Contractor: Phone: Sewer & Water Contractor: Phone: Fire Suppression Contractor. Phone: NOTE. Plans and supporting documents that you submit are considered to be public information. Portions of the Information maybe classified as non-public if you provide specific reasons that would permit the City to conclude that they are trade secrets. You may subscribe to receive an electronic notification from the City of proposed ordinances by signing up for an email update on the City's website at www. citvofeagan.com/subscribe. CALL BEFORE YOU DIG. Contact Gopher State One Call at (651) 4540002 or www.gooherstateonecall.org for protection against underground utility damage. Contact Gopher State One Call 48 hours before you Intend to dig to receive locates of underground utilities. I hereby acknowledge that this information Is complete and accurate; that the work will be In conformance with the ordinances and codes of the City of Eagan; that I understand this is not a permit, but only an application for a permit, and work is not to start without a permit; that the work will be in accordance with the approved plan In the case of work which requires a review and approval of plans. xDennis Pitzl Applicant's Printed Name x 6 -- Applicant's Signature Required Information for Deck Permits a� c m CL C 0 0 V 3 c 8 8 8 8 19 8 8 8 8 Site Address: Dimensions of deck: 20 x 14 w/landing 8 Height of deck from ground: 7' Size of posts: 6 x 6 8 Spacing of posts: 6' Footing diameter: Helical (use 2 existing Cylinder) 8 Footing depth: 48" Min If sizes vary, leave blank and indicate individual sizes on plans. o *42" minimum for traditional concrete footing. Specify if using engineered footings [L Joist to beam: (i.e., Diamond Pier) and provide installation instructions. Size of beam(s): 2 -2 x 10 8 Drop or flush beam(s): Drop *Example: 2 — 2° x 12° Cantilever on beam(s): 1' Side Size of joists: 2 x 10 8 Spacing of joists: 16" Species of lumber for framing: AC2 Dimensions of floorboards: 2 x 6 8 Floorboard type: TimberTech Composite Pattern of floorboards: 90 *i.e: perpendicular (90 degrees) to joists, 30/45/or 60 degrees to joists Stair width: 3'6" approx 8 Stair stringer spacing: 12" or less Stair length: 7' Approx Will the deck be built around a cantilevered area? (i.e., a bay with a patio door) es / No What type of floor framing will the ledger be attached to? (i.e., 1 -joist, floor truss, 2° x 10", etc.) 2 x 10 I �m c ! Distance to properly lines: 8 Side 1: 30' 8 Rear. 52' 8 Side 2: 30' ❑ Other e Type of hardware to be used: Ledger board: 8 Ledger board connection: _Hanger ❑ Any other hardware used: r Perm Two (2) copies of plans that include: ❑ Cross section view ❑ Plan view ❑ Stair framing view ❑ Applicable supplemental information Site plan, drawn to scale on survey or plat map, including: ❑ Deck dimensions ❑ Distance to property lines 1 8 Lateral load connection: D11tz or Similar CL CL Beam to posts: e ❑ Post cap (manufacturer/model) 4 E 8 Through bolts (size) 1/2" Carriage w/washers ❑ Other approved type o [L Joist to beam: ® Joist hanger [].,Other ❑ Any other hardware used: r Perm Two (2) copies of plans that include: ❑ Cross section view ❑ Plan view ❑ Stair framing view ❑ Applicable supplemental information Site plan, drawn to scale on survey or plat map, including: ❑ Deck dimensions ❑ Distance to property lines FOR OFFICE USE ONLY :.wRir, i wil � / �co Calculated Valuatlon Plan Review (25%_ 1009/62L) Census Code # of Units # of Buildings Type of Construction �($ REQUIRED INSPECTIONS Footings (New Building) �( Footings (Deck) Footings (Addition) Foundation Foundation Before Backfill Roof: _Ice & Water _Final p --Framing /-30 Minutes 1 Hour Fireplace: _Rough In Air Test _Final Insulation Sheathing Sheetrock Fire Walls Braced Walls Shower Pan Reviewed By: Occupancy IU -J. Code Edition AWZ& Z W Zoning '�- Stories Square Feet Length Width Meter Size: MCES System SAC Units City Water Booster Pump PRV Fire Suppression Required Final / C.O. Required Final / No C.O. Required HVAC _ Service Test Gas Line Air Test _ Hood Pool: _Footings Air/Gas Tests _Final Drain Tile Siding: _Stucco Lath _Stone Lath _Brick _ EFIS Windows Retaining Wall: _ Footings _ Backfill _ Final Radon Control Fire Suppression: _Rough In _Final Erosion Control Other: . Building Inspector RESIDENTIAL FEES Site Address: C C Permit #: i (� 3 SUB TYPES Plan Review g�• Z _ Foundation _ Fireplace _ Porch (3 -Season) _ Miscellaneous _ Single Family _ Garage _ Porch (4 -Season) _ Accessory Building Multi jt- Deck _ Porch (Screen/Gazebo/Pergola) Radio Read 01 of _ Plex _ Lower Level _ Pool Copies WORK TYPES TOTAL $ 0.00 New _ Repair _ Siding _ Retaining Wall Addition _ Fire Repair _ Reroof _ Move Building Alteration _ Water Damage Windows _ Demolish Building" Replace _ Egress Window _ _ Solar "Demolition of entire building - give PCA handout to applicant :.wRir, i wil � / �co Calculated Valuatlon Plan Review (25%_ 1009/62L) Census Code # of Units # of Buildings Type of Construction �($ REQUIRED INSPECTIONS Footings (New Building) �( Footings (Deck) Footings (Addition) Foundation Foundation Before Backfill Roof: _Ice & Water _Final p --Framing /-30 Minutes 1 Hour Fireplace: _Rough In Air Test _Final Insulation Sheathing Sheetrock Fire Walls Braced Walls Shower Pan Reviewed By: Occupancy IU -J. Code Edition AWZ& Z W Zoning '�- Stories Square Feet Length Width Meter Size: MCES System SAC Units City Water Booster Pump PRV Fire Suppression Required Final / C.O. Required Final / No C.O. Required HVAC _ Service Test Gas Line Air Test _ Hood Pool: _Footings Air/Gas Tests _Final Drain Tile Siding: _Stucco Lath _Stone Lath _Brick _ EFIS Windows Retaining Wall: _ Footings _ Backfill _ Final Radon Control Fire Suppression: _Rough In _Final Erosion Control Other: . Building Inspector RESIDENTIAL FEES L 5, goo Calculated Valuation Base Fee Plan Review g�• Z State Surcharge 3. MCES SAC City SAC Utility Connection Charge S&W Permit & Surcharge Treatment Plant Radio Read Other: Copies TOTAL $ 0.00 Zfl j� � : 3