Loading...
EA179815 - Building - Single Fam - Issued Date 01/06/2023 (2)PERMIT City of Eagan , , , Permit Type: Building 3830 Pilot Knob Rd Permit Number: EA179815 Eagan, MN 55122 -EAGAN (651) 675-5675 111111111111 www.cityofeagan.com * E R 1 7 9 8 1 S Date Issued: 1/6/2023 Site Address: 704 Nauvoo Lane Lot: 2 Block: 1 Addition: Moroni PID: 10-48600-01-020 Use: * 10-48600-0 1-020 Description: Sub Type: Single Fam Construction Type: V -B Work Type: New Description: Census Code: 101- Single Family Houses Occupancy: IRC- I Zoning: A Square Feet: 0 Comments: Improvements to the home may require smoke detectors in all bedrooms. Carbon monoxide detectors are required within 10 feet of all sleeping room openings in residential homes (Minnesota State Building Code). Fee Summary: 3/4" Meter $300.00 6101.4509 Valuation: 682,616.00 BL - Base Fee $4,893.15 0801.4085 BL - Plan Review 65% $3,180.55 0720.4222 City SAC (01 Unit) $139.00 9376.4681 Radio Read Unit (Domestic) $240.00 6101.4509 Surcharge - Based on Valuation $341.31 9001.2195 Treatment Plant - Residential $1,126.00 6101.4685 Water Supply & Storage $1,812.40 6101.4680 SAC (1 unit) - Single Family House $2,485.00 9220.2275 Total: $14,517.41 Contractor: - Applicant - Owner: Homes By Tradition LLC Marcus Ploeger 16972 Brandtjen Farm Drive 704 Nauvoo Ln Lakeville MN 55044 Eagan MN 55123 (612)791-1870 This permit shall be null and void if work does not start within 180 days of issuance, or if work is suspended for 180 days or more after started. I hereby acknowledge that I have read this application and state that the information is correct and agree to comply with all applicable State of Minnesota Statutes and City of Eagan Ordinances. Applicant/Permitee: Signature ssued B?' Signature ECEIVE UC'f 1 t 2022 BY. I For Office Use I I I I Building Permit I % �s �4 �• ,s®® I S&W Permit #:EAGAN I ( 1 o.•• ••gyp 51-7-41 Permit Fe J 1-7 . 41 I Date Received: 0 3830 PILOT KNOB ROAD I EAGAN, MN 55122-1810 I I (651) 675-5675 1 FAX: (651) 675-5694 I Date Issued: buildinginspectionsa)cityofeagan.com t -------------------- RESIDENTIAL BUILDING PERMIT APPLICATION Date: 10.21 •22 Site Address: 704 Nauvoo Lane Unit#: Applicant is: ❑ Owner 14 Contractor Name: Marcus Ploeger Homeowner Address: City: g 710 Marsh Ct. Eagan ( r State: MN Zip: 55123 _ Phone 651-788-28� Email: MPloeger@Taftlaw.com Description of work: Building a New Residential Home TWorkype f Construction Cost: $1,474,860 �� MGron l nad tl ori Single Type of building:� S ng a F amity ❑ Townhome, of units 11 Twin Home Company: Homes by Tradition Contact: Tom Sand Building Address: 16972 Brandtjen Farm Drive City: Lakeville I Contractor MN 55044 952-322-872tom.sand@hbtllc.com State: Zip: Phone: Email. License #: BC556362 Ex iration Date: 3/31/2024 Sewer & Company: Enebak Construction Company Contact: Mike Stopskl Water 16970 Brandtjen Farm Drive Lakeville Contractor Address: City: Required for p State: MN Zi 55044 Phone: 612-670-94% Email: mikes@enebak.com new construction PB645595 12/31/23 License #: Expiration Date: 1 understand that Plumbing, Mechanical, and Fire Suppression work require separate applications. I NOTE: Plans and supporting documents that you submit are considered to be public information. Portions of the information may be classified as non-public if you provide specific reasons that would permit the City to conclude that they 3 are trade secrets. CALL BEFORE YOU DIG. Contact Gopher State One Call at (651) 454-0002 or www.gopherstateonecall.org for protection against underground utility damage. Contact Gopher State One Call 48 hours before you intend to dig to receive locates of underground utilities. I hereby acknowledge that this information is complete and accurate; that the work will be in conformance with the ordinances and codes of the City of Eagan; that I understand this is not a permit, but only an application for a permit, and work is not to start without a permit; that the work will be in accordance with the approved plan in the case of work which requires a review and approval of plans. Digitally signed by Thomas J. Sand Thomas J. Sand DN cn=ThomasJ land, o=Homesby, LS X T h o m a s J. Sand Tradition, .ea —Construction Manager, email=tom. 10.20 hbtJ1d12,43 d.05m, 5'00' �( Dale'. 2022 10.20 12 63'.05 -05'00' Applicant's Printed Name Applicant's Signature SUB TYPES T Single Family _ 01 of _ Plex Deck WORK TYPES New _ Addition _ Alteration Replace FOR OFFICE USE ONLY Site Address: 704 Nauvoo Lane Fireplace _ Foundation Garage Repair _ Fire Repair _ Water Damage Egress Window DESCRIPTION MCES System ?K Calculated Valuation Z. (ply, `E Plan Review 025% X100% Census Code Booster Pump # of Units PRV # of Buildings Fire Suppression Required Type of Construction via Lower Level Porch Pool Siding _ Reroof _ Windows Solar Permit #: �I Retaining Wall Move Building _ Demolish Building* 'Demolition of entire building — give PCA handout to applicant Occupancy 124-1 MCES System ?K Code Edition AfNg,' -iosc, SAC Units L Zoning A City Water Stories Booster Pump Square Feet PRV Fire Suppression Required Separate Stormwater Management Permit Required REQUIRED INSPECTIONS Footings: )( New Addition Deck X_ Foundation: A Before Backfill /,Poured Wall Framing: 1 Hour Residential Alteration Y Z►,,, ` Braced Wall Framing/Blocking Braced Wall Sheathing (prior to house wrap) j( Interior Braced Wall Panel(s) Firewalls Insulation V- Fireplace: XRough In 0L Air Test Final HVAC: Rough In Final Radon Control K. Siding: _Stucco Lath _Stone Lath _Brick J� Roof: X Ice & Water XFinal Erosion Control Pool: _Footings —Air/Gas Tests _Final Retaining Wall: _Footings _Backfill _Final Fire Suppression: _Rough In _Final Windows Other: Final/No C.O. Required Final/C.O. Required Reviewed By: `�S Building Inspector FEES Calculated Valuation Base Fee Plan Review State Surcharge Met Council SAC City SAC Treatment Plant Water Supply & Storage S&W Permit & Surcharge Meter Radio Read Other: (v`bz��ib.4w 19`13 ,3% $0 . .34/. 50 TOTAL $ 0.00 r ntct.4.d - >k z X 95.73 ' 2-ztwO (j'"GE Cc. e—e Gr Ent -I C_rt-re-et PAf,o Floar- 990 x '0.4 t .,Irp,cr'S.9 i Zo X lie - LbD X 4D - io�l - 247 1 X .7s "131,2 541 X 55 - '13 " P47*5'19. 93 i.0ej2t.4'I10. 110 City Inspection Dept. Copy EAGAN City Forester Copy Applicant/Builder Copy INDIVIDUAL RESIDENTIAL LOT TREE PRESERVATION PLAN SUMMARY CITY OF EAGAN FORESTRY DIVISION 651-675-5300 (BUILDER, PLEASE READ ATTACHMENTS) Development Moroni Addition Lot Number 2 Block Number 1 Address 704 Nauvoo Lane Builder Homes by Tradition Phone Number: Contact: Tree Protection Requirements: 952-322-8422 Tom Sand X Tree Protection Fencing to be Installed on Site (Orange Poly Fence) Oak Tree Pruning (Immediately seal wounds during April 1 to July 31) Therapeutic Pruning Required Retaining Wall To Be Installed Other: Replacement Trees: X Not Required: As Follows: Attachments: X Yes (Refer to attac WRESTRY DIVISION No REVIEWED Additional Notes:pV ' `. DATE TREE PRESERVATION PLAN - 704 Nauvoo Lane.docx 704 Nauvoo Lane y _ •c, ...---. .d:.�x Z . twv.*t`-k"s::. 1 � .. .1� "�. $ . � _ F��.q} r Ya4,- —V 17 :VVr w t • n V. -R,. ' ,$-"S: ;> f- ...Mit� a_ ,'day,' _ -� ,'�'' '• � +oiii��r M& J Y• 1 lin= 188ft Lakes Aerial Street Names N Storm Basin A EAGAN Wetlands October 27, 20 Sections Numbers MapP W.gRA A—i.if— -1 a Is i I OV0N Doi E.�i {. i�o.."os � 0004 �__% �.. �y gY sB� li O I i •i i i �� i 1 � T� IIp�s; — — — — — — — — — — II i a fwd. 01- .3t CL it i , �•, raj y [� is, � I e �F \ 3 6$! x•.11 I• • 9W- i 4 E� .� t 'i 5 jW 1 I ''' sc^srs,�cseasgal a ;gioa�o€o�ES��a� o TREE PRESERVATION PLAN REVIEW — INDIVIDUAL LOT • • • EAGAN Date Building Permit Application Received EXC.10/14/22, BLDG. 10/21/22 Development Moroni Addition Lot 2 Block 1 Site Address 704 Nauvoo Lane Builder Homes by Tradition Contact Tom Sand Telephone 952-322-8422 E-mail tom.sand(aD_hbtllc.com Property/Lot Owner Name Marcus Telephone 651-788-2814 E-mail MPloeger(a),taftlaw.com Office Plan Review —Date 10/27/22 Notes Tree inventory was submitted with the certificate of survev with this application. Site contains 102 significant trees. Of the significant trees, fourteen are proposed for removal. The removal of significant trees less the allowable removal limit therefore, no mitigation is required. Tree preservation plan received and approved for EX/Grading permit 10/19/22 Tree Preservation Data Total Significant Woodland Area Total Significant Trees Woodland To Be Removed Trees To Be Removed Allowable Woodland Removal (20%) Allowable Tree Removal (20%) Original Plan sq. ft 102 sq. ft 13 sq. ft 21 Revised Plan Required Mitigation YES (or) NO Calculated Mitigation Amounts Original Plan - Category A Category B Category C Revised Plan - Category A Category B Category C sq. ft sq. ft sq. ft Site Inspection — Date 10/26/22 Notes All silt and tree protection fence installed. House location staked, and trees proposed for removal marked. Reduced removals stats to account for one severely EAB infested ash. Approval to Proceed 10/27/22 G:\Forestry\TreePreservation\Tree Preservation Plan Review - Individual Lot.docx Original Tree Preservation Plan Approved – Date 10/19/22y Cj— Forwarded to Inspections – Date 10/27/22 By _ Zd Discussion/Meetings with Builder/Owner - Tom Sands 10/12/22 Notes T -Phone call with Tom, Revised Tree Preservation Plan Approved– Date By, Forwarded to Inspections– Date By Additional Field Inspections Date Notes Date Notes Date Notes Date Notes G:\Forestry\TreePreservation\Tree Preservation Plan Review - Individual Lot.docx xw MORONI ADDITION LOT 2 BLOCK 1 -TREE PRESERVATION CALCULATION WORKSHEET 9/6/2022 Property Address: 704 Nauvoo Lane Development Type = Single Family Residential Existing Allowable Actual Actual Required Trees Removal Removal Preserved Mitigation 102 Trees 20.0% 13 Trees 89 Trees -8 Btrees 21.0 Trees 12.7% 87.3% (Applicant to mitgate: Category of Tree Specimen Trees Hdwd Deciduous 21-30" Soft Deciduos >24" Conifer > 24' (12" dbh) Hdwd Deciduos 6-20" Soft Deciduous 12-24" Conifer 12-24'(<12" dbh) total = 0 Trees) Number of Trees Removed Mitigation Total Total Per Tree (B) Mitigation (B) Mitigation (A) 0 6 0 0 0 4 0 0 0 4 0 0 0 4 0 0 0 2 0 0 0 2 0 0 0 2 0 0 0 Cat. A trees 0 TREE MITIGATION = 0 Category B Trees QUANTITY OF MITIGATION TREES PROVIDED= 0 Category B Trees Balance of mitigation trees to be fulfilled = 0 Category B Trees Cash equivalent due to fulfill tree mitigation = $0 New Construction Energy Code Compliance Certificate Per R401.3 Certificate. A building certificate shall be posted on or in the electrical distribution Date Certificate Posted panel. Mailing Address of the Dwelling or Dwelling Unit City t L - At 1b'.'q Name of Residential Contractor MN License Number Silver Tree Plumbing and Heating MB005441 THERMAL ENVELOPE RADON CONTROL SYSTEM Type: Check All That Apply X Passive (No Fan) Active (With fan and monometer or other Nc system monitoring device) N � Location (or future location) of Fan: T o c, o -6 U a� a o o a a� m 7 76 Q m m OO N T Insulation Location C ° O N N ui O O. z m m U O `o LL j( w O N Z6 _' _' E E � -v -o o N S o n a o o z LL LL LL LL m E rn i Other Please Describe Here Below Entire Slab R-10 X Foundation Wall R-10 X R10 Exterior Perimeter of Slab on Grade X Rim Joist (1st Floor) X Interior Rim Joist (2nd Floor+) R- X Interior Wall R-20 X Ceiling, flat R-49 X Ceiling, vaulted R-49 X Bay Windows or cantilevered areas R-30 X Floors over unconditioned area R-30 X 4 - Describe other insulated areas Building envelope airtightness: Duct system air tightness: Windows & Doors Heating or Cooling Ducts Outside Conditioned Spaces Average LI -Factor (excludes skylights and one door) U: 0.32 Not applicable, all ducts located in conditioned space Solar Heat Gain Coefficient (SHGC): 10.32 R8 I R -value MECHANICAL SYSTEMS Make-up Air Select a Type Appliances Heating System Domestic Water Cooling System X Heater Not required per mech. code Nat Gas NAT GAS Electric Fuel Type Passive Bryant RHEEM Bryant Manufacturer Powered 26TB42060V QTY PROG75 BA13NA048 Interlocked with exhaust device. Model Describe: Input in BTUS: 120,000 Capacity in Gallons: 75 Output in Tons: 4 Other, describe: Rating or Size AFUE or 96% SEER 13 Location of duct or system: Efficiency HSPF% /EER Heating Loss Heating Gain Cooling Load Residential Load Calculation 94,103 35,772 39,969 Cfm's " round duct OR MECHANICAL VENTILATION SYSTEM " metal duct Describe any additional or combined heating or cooling systems if installed: (e.g. two furnaces or air Combustion Air Select a Type X Not required per mech. code source heat pump with gas back-up furnace): Passive Select Type Heat Recover Ventilator (HRV) Capacity in cfms: Low: High: I Other, describe: X Energy Recover Ventilator (ERV) Capacity in cfms: Low: 1104 High: 1209 Location of duct or system: Mech Room X Balanced Ventilation capacity in cfms: 240 X Location of fan(s), describe: I Bath 1, Bath 2, Bath 3,Primary Bath, Pool Bath, Powder Bath Cfm's X Capacity continuous ventilation rate in cfms: 1 104 6 " round duct OR X Total ventilation (intermittent + continuous) rate in cfms: 1584 1 5 " metal duct Builders Associaton of Minnesota version 101014 Table 501.3.1 Procedure to Determine Makeup Air Quantity for Exhaust Equipment in Dwellings Use the Apprc priate Column to Estimate House Infiltration One or multiple power vent or One or multiple fan -assisted One atmospherically vented Multiple atmospherically cfm direct vent appliances or no appliances and power vent or gas or oil appliance or one vented gas or oil appliances Passive Opening combustion appliancesA direct vent appliancesB solid fuel applianceC or solid fuel appliancesD Is) pressure factor (cfm/sf) 0.15 0.09 0.06 0.03 b) conditioned floor area (s2 4 Passive Opening 67-109 42-66 (including unfinished basements) 5939 0 Passive Opening 0 Estimated House Infiltration 47-69 29-42 6 Passive Opening (cfm): [1a x 1b] 890.85 0 0 0 2.a) Exhaust Capacity 233-317 144-195 100-135 62-83 continuous exhaust -only Passive Opening with Motorized Damper 318-419 196-258 136-179 ventilation systems (cfm): (not 9 Passive Opening with Motorized Damper 420-539 259-332 applicable to balanced ventilation 111-142 10 Passive Opening with Motorized Damper 540-679 systems such as HRV) 0 0 0 0 b) clothes dryer 135 135 135 135 c) 80% of largest exhaust rating (cfm): (not applicable if recirculating system or if powered makeup air is electrically interlocked and matched to exhaust) 480 0 0 0 d) 80% of next largest exhaust rating (cfm): (not applicable if recirculating system or If powered makeup air is electrically interlocked and matched to exhaust) 0 0 0 Total Exhaust Capacity (cfm): [2a+2b+2c+2d] 615 135 135 135 3.a) Makeup Air Requirement Total Exhaust Capacity (from above) 615 135 135 135 b) Estimated House Infiltration (from above) 890.85 0 0 0 Makeup Air Ouartity (cfm): [3a — 3b] (if value is negative, no makeup air is needed) -275.85 1 135 1 135 1 135 T. For Makeup Air Opening Sizing, refer to Table 501.3.2 A Use this column if there are other than fan -assisted or atmospherically vented gas or oil appliances or if there are no combustion appliances. B Use this column if there is one fan -assisted appliance per venting system. Other than atmospherically vented appliances may also be included. C Use this column if there is one atmospherically vented (other than fan -assisted) gas or oil appliance per venting system or one solid fuel appliance. D Use this column if there are multiple atmospherically vented gas or oil appliances using a common vent or if there are atmospherically vented gas or oil appliances and solid fuel appliances. A Use this column if there are other than fan -assisted or atmospherically vented gas or oil appliances or If there are no combustion appliances. B Use this column if there is one fan -assisted appliance per venting system. Other than atmospherically vented appliances may also be Included. C Use this column if there is one atmospherically vented (other than fan -assisted) gas or oil appliance per venting system or one solid fuel appliance. D Use this column if there are multiple atmospherically vented gas or oil appliances using a common vent or if there are atmospherically vented gas or oil appliances and solid fuel appliance(s). E An equivalent length of 100 feet of round smooth metal duct is assumed. Subtract 40 feet for the exterior hood and ten feet for each 90 - degree elbow to determine the remaining length of straight duct allowable. F If flexible duct is used, increase the duct diameter by one Inch. Flexible duct shall be stretched with minimal sags. G Barometric dampers are prohibited in passive makeup air openings when any atmospherically vented appliance is installed. H Powered makeup air shall be electrically interlocked with the largest exhaust system. Table 501.3.2 Makeup Air Opening Sizing Table for New and Existing Dwellings One atmospherically Multiple atmospherically One or multiple power vent One or multiple fan -assisted vented gas or oil appliance vented gas or oil or direct vent appliances or appliances and power vent or one solid fuel appliances or solid fuel no combustion appliancesA or direct vent appliancesB applianceC appliancesD Passive makeup air opening duct diameterE F,G Type of opening or system cfm cfm cfm cfm inches Passive Opening 1-36 1-22 1-15 1-9 3 Passive Opening 37-66 23-41 16-28 10-17 4 Passive Opening 67-109 42-66 29-46 18-28 5 Passive Opening 110-163 67-100 47-69 29-42 6 Passive Opening 164-232 101-143 70-99 43-61 7 Passive Opening 233-317 144-195 100-135 62-83 8 Passive Opening with Motorized Damper 318-419 196-258 136-179 84-110 9 Passive Opening with Motorized Damper 420-539 259-332 180-230 111-142 10 Passive Opening with Motorized Damper 540-679 333-419 231-290 143-179 11 Powered Makeup AirH >679 >419 >290 >179 not licable A Use this column if there are other than fan -assisted or atmospherically vented gas or oil appliances or If there are no combustion appliances. B Use this column if there is one fan -assisted appliance per venting system. Other than atmospherically vented appliances may also be Included. C Use this column if there is one atmospherically vented (other than fan -assisted) gas or oil appliance per venting system or one solid fuel appliance. D Use this column if there are multiple atmospherically vented gas or oil appliances using a common vent or if there are atmospherically vented gas or oil appliances and solid fuel appliance(s). E An equivalent length of 100 feet of round smooth metal duct is assumed. Subtract 40 feet for the exterior hood and ten feet for each 90 - degree elbow to determine the remaining length of straight duct allowable. F If flexible duct is used, increase the duct diameter by one Inch. Flexible duct shall be stretched with minimal sags. G Barometric dampers are prohibited in passive makeup air openings when any atmospherically vented appliance is installed. H Powered makeup air shall be electrically interlocked with the largest exhaust system. Load Short Form Job: - wrightsoft Date: 9112122 Entire House By: Silver Tree Plumbing and Heating LLC 1335 Mendota Heights Rd, Mendota Heights, MN 55120 Phone: 651-319-4200 Email. andyf@silvertreepandh.com Web: viww.silvertreepandh.com Project Information For: HBT- Ploeger Residence HEATING EQUIPMENT Make Generic Design Information Trade Htg CIg Infiltration Outside db ('F) -15 88 Method Simplified Ins idedb(°F) 70 72 Construction quality Semi -tight Design TD (°F) 85 16 Fireplaces 1 (Semi -tight) Dailyrange - M Ins ide humidity (%) 30 50 Ivbisturedifference (gr/lb) 30 50 HEATING EQUIPMENT Make Generic Htg load Trade Htg AVF Ivbdel AFUE 96 AH RI ref (Btuh) Efficiency 96 AFUE Heating input 98024 Btuh Heating output 94103 Btuh Temperature rise 52 °F Actual airflow 1703 cfm Air flow factor 0.019 cfm /Btu h Static pressure 0 in H2O Space thermostat Room4 COOLING EQUIPMENT Make Generic Trade Cond SEER 13.0 Coil AHRI ref Efficiency Sensible cooling Latent cool ing Total cooling Actual airflow Air flow factor Static pressure Load sensible heat ratio 11.6 EER, 13 SEER 35772 Btuh 15331 Btuh 51103 Btuh 1703 cfm 0.044 cfm Btu h 0 in H2O 3.q0 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft") (Btuh) (Btuh) (cfm) (cfm) Room1 2233 23062 3123 435 138 Room2 2233 37387 20586 705 910 Room4 1597 26316 14125 496 624 Room5 190 3622 714 68 32 Entire House 6254 90387 38547 1703 1703 Other equip loads 3715 0 Equip. @ 0.93 RSM 35772 Latent cooling 4197 Bold/italic values have been manually overridden Calculations approved byACCAto meetall requirements of Ntanual J 8th Ed. wrightsofL- 2022 -Dec -20 1108:49 fill .­...,,.., Right -Su He@ Universal 202222 0.01 RSU64702 Paget _.echt\Documents\Wdghtsoft HVAC\HBT- Ploegecrup Calc = W8 Front Door faces: E �- wrightsoft Building Analysis Da 91112,22 Entire House By: Silver Tree Plumbing and Heating LLC 1335 Mendota Heights Rd, Mendota Heights, MN 55120 Phone: 651-319-4200 Email. andyf@silvenreepandh.00m Web:—silvedreepandh.com Project• • For: HBT- Ploeger Residence Heating Component Design Conditions Btu %of load Walls Location: 29316 Indoor: Heating Cooling Mnneapolis-St Paul Intl, W, US 30.4 Indoor temperature (°F) 70 72 Elevation: 872 ft Ceilings Design TD (°F) 85 16 Latitude: 45°N 2.1 Relative humidity(%) 30 50 Outdoor: Heatingq Cooling Nbisture difference (gr/lb) 30.0 50.0 Drybulb(°F) 1s 88 Infiltration: 0 Dal yrange (°F) 17 (M ) Ivbthod Simplified 3.9 Wetbulb(°F) 72 Construction quality Semi -tight Adjustments Wind speed (mph) 15.0 7.5 Fireplaces 1 (Semi -tight) 1 Heating Component Btu M2 Btu %of load Walls 5.7 29316 31.2 Glazing 40.0 28641 30.4 Doors 28.1 6584 7.0 Ceilings 1.7 4072 4.3 Floors 2.1 4746 5.0 Infiltration 3.8 17028 18.1 Ducts 0 0 Piping 0 0 Humidification 3715 3.9 Ventilation 0 0 Adjustments 0 Total 1 1 94103°00 JI icsaiirig Component I Btuh/ft2 Btu 1/6 of load Walls 0.8 4172 10.8 Gazing 34.0 24346 63.2 Doors 9.5 2219 5.8 Ceilings 1.1 2498 6.5 Floors 0 0 0 Infiltration 0.3 1532 4.0 Ducts 0 0 Ventilation 0 0 Internal gains 3780 9.8 Blower 0 0 Adjustments 0 Total 38547 100.0 Latent Cooling Load = 419' Btuh Overall U -value = 0.080 Btu .!ft? °F Data entries checked. Gazing VAI IrteTd (mins Infiftrai;crl Celirgs Lbws (erg Bold/italic values have been manually overridden -Pld- wrightsoftt- 2022-D-2011:08:49 �+` •-• Right -Suite® Universal 2022 22.0.01 RSU64702 Page i91.� ,,,echt\Documents\W rightsoft HVAC\HBT- Ploager.rup Calc = W 8 Front Door f ices: E - wrightsoft Component Constructions oo 9112/22 Entire House By: Silver Tree Plumbing and Heating LLC 1335 Mendota Heights Rd, Mendota Heights, MN 55120 Phone: 651-319-4200 Email: andyf@silverlreepandh,wm Web. vHvw.silverireepandh.com Project• • For: HBT- Ploeger Residence Construction descriptions Design Conditions LLvalue Btuh/t'-'F Insul R ft?°F/Stuh Rg HTM Btuh/ft' Location: Gain Btuh Indoor: Heating Cooling M nneapoli s -St Paul Inti, W, US Indoor temperature (°F) 70 72 Elevation: 872 ft 530 Design TD (°F) 85 16 Latitude: 45oN 1.13 Relative humidity(%) 30 50 Outdoor: Heating Cooling bbisture difference (gr/lb) 30.0 50.0 Dry bulb (°F) -15 88 Infiltration: 0.065 21.0 Dailyrange (°F) - 17 ( M) kbthod Simplified Wet bulb (°F) - 72 Construction quality Semi -tight 4780 Wind speed (mph) 15.0 7.5 Fireplaces 1 (Semi -tight) 0.065 Construction descriptions Or Area ft' LLvalue Btuh/t'-'F Insul R ft?°F/Stuh Rg HTM Btuh/ft' Loss Clg HIM Btuh BWh/ft' Gain Btuh Walls 12F-Osw: Frmwall, vnl ext, 1/2" wood shth, r-21 cav ins, 1/2" gypsumn 530 0.065 21.0 5.52 2929 1.13 601 board intfnsh, 2"x6" w ood firm, 16" o.c. stud a 805 0.065 21.0 5.52 4447 1.13 913 s 880 0.065 21.0 5.52 4862 1.13 998 w 865 0.065 21.0 5.52 4780 1.13 981 all 3080 0.065 21.0 5.52 17018 1.13 3494 1513-10s3c-6: Bg wall, heavy dry or light darrp soil, concrete w all, r -10n 421 0.069 10.0 6.16 2596 0.28 118 ins, 8" thk a 593 0.069 10.0 6.16 3656 0.28 167 s 245 0.069 10.0 6.16 1508 0.28 69 w 475 0.069 10.0 6.16 2929 0.28 134 all 1735 0.069 10.0 6.16 10690 0.28 488 Pz� 12 w ., ext, 1;/' wood shth, r-21 cav ins, 1/2" gypsum 291 0.065 21.0 5.52 1608 0.65 190 board int fns h, 2"x 6" w ood frrrt 16" ox. stud Windows 4A5-2ov: 2 glazing, clr low -e out r, argon gas, insulated vinyl fir in mat, a 330 0.470 0 40.0 13184 36.3 11993 clr innr, 1/2" gap, 1/4" thk; 6.67 ft head ht s 118 0.470 0 40.0 4707 21.8 2573 w 269 0.470 0 39.9 10751 36.3 9780 all 717 0.470 0 39.9 28641 34.0 24346 Doors 11 D0: Door, wd sc type a 24 0.390 0 33.1 796 11.2 268 s 24 0.390 0 33.1 796 11.2 268 w 24 0.390 0 33.1 796 11.2 268 n 24 0.390 0 33.1 796 11.2 268 all 96 0.390 0 33.1 3182 11.2 1073 11 P0: Door, mtl pur core type w 138 0.290 10.5 24.6 3402 8.31 1147 Ceilinnggs 16 ad: Attic ceiling, asphalt shingles roof mat, r-50 ceil ins, 5/8" 1787 0.020 50.0 1.70 3038 1.04 1864 gypsum board int fnsh 577 0.020 50.0 1.70 980 1.04 602 all 2364 0.020 50.0 1.70 4019 1.04 2466 wrightsoft• 2022-D-20 11:08:49 Rght-Suile®Universa1202222.0.01 RSU64702 Page ...echt\Documents\W night soft HVAC\HBT- Ploeg or. rup Calc =M18 Front Dcar faces: E Cpart ceiling,: C part ceiling, carpet fir fnsh, frm fir, 12" thkns, 5/8" gypsum board int fnsh Roors 21 A -24t: Bg floor, heavy dry or light damp soil, 6' depth 3 0.216 1.0 18.3 53 112 33 2233 0.025 0 2.13 4746 0 0 :L. _ weiyhtaofY' � 2022 -Dec -201 Rig M-Suffe® P Universal 202222.0.01 RSU64702 aget � Page 2 ...ecM\Docum eMs\Wrightaoft HVAC\HBT- Ploeger.rup Calc =MIB Front Doorfaces: E - wrightsoft' Component Constructions Dae: 9112/22 Room 1 By: Silver Tree Plumbing and Heating LLC 1335 Mendota Heights Rd, Mendota Heights, MN 55120 Phone: 651-319-4200 Email: andyf@silvertreepandh.wm Web: -silvertreepandh.com Project• • For: HBT- Ploeger Residence Location: Minneapolis -St Paul Inti, MN, US Elevation: 872 ft Latitude: 45°N Outdoor: Heating Drybulb (°F) -15 Dailyrange (°F) Wet bu lb (T) - Wind speed (mph) 15.0 Heating Indoor: 70 Indoor temperature (°F) 85 Design TD (°F) 30 Relative humidity(%) Cooling Ivbisturedifference (gr/lb) 88 Infiltration: 17 ( M ) K/bthod 72 Construction quality 7.5 Fireplaces Heating Cooling 70 72 85 16 30 50 30.0 50.0 Simplified Semi -tight 1 (Semi -tight) Construction descriptions Or Area LLvalue Insul R Ftg HTM Loss Clg HTM Gain W Btuh/R'-°F ft-°F/Bluh BUh/fN Btuh BWh/ft' Btuh Walls 12F-Osw: Frmwall, vnl ext, 1/2" wood shth, r-21 cav ins, 1/2" gypsums 107 0.065 21.0 5.52 591 1.13 121 board intfnsh, 2"x6"wood frm 16" o.c. stud w 76 0.065 21.0 5.52 420 1.13 86 all 183 0.065 21.0 5.52 1011 1.13 207 15B-10s3c-6: Bg wall, heavy dry or light damp soil, concrete wall, r -10n 421 0.069 10.0 6.16 2596 0.28 118 ins, 8" thk a 593 0.069 10.0 6.16 3656 0.28 167 s 245 0.069 10.0 6.16 1508 0.28 69 w 475 0.069 10.0 6.16 2929 0.28 134 all 1735 0.069 10.0 6.16 10690 0.28 488 Partitions (none) Windows 4A5-2ov: 2 glazing, clr low -e outr, argon gas, insulated vinyl frm mat, s 70 0.470 0 40.0 2787 21.8 1524 clr innr, 1/2" gap, 1/4" thk; 6.67 ft head ht Doors 11 P0: Door, mtl pur core type w 42 0.290 10.5 24.6 1035 8.31 349 Ceilings (none) Roors 21 A -24t: Bg floor, heavy dry or light damp soil, 6' depth 2233 0.025 0 2.13 4746 0 0 -wrig!>titaOK• 2022 -Dec -2011:06:49 ,,,,,-. .. ........., ..,., Right-Suft.V Universal 202222.0.01 RSU64702 Page3 10M echt\D ocum ents\Wrightsoft HVAC\HBT- Ploager.mp Cale =Ml8 Front D oor faces: E -{,�J.- Component Constructions Job: I wrightsoft- p Date: 9/12/22 Room2 By: Silver Tree Plumbing and Heating LLC 1335 Mendota Heights Rd, Mendota Heights, MN 55120 Phone: 651-319-4200 Email. andyf@silvertreepandh.com Web: v -v silvertreepandh.com Project• • For: HBT- Ploeger Residence Location: M nneapoli s -St Paul Intl, NN, US Elevation: 872 ft Latitude: 45 ° N Outdoor: Heating Drybulb (°F) -15 Dailyrange (°F) Wetbulb(°F) - Wind speed (mph) 15.0 Heating Indoor: 70 Indoor temperature (°F) 85 Design TD (°F) 30 Relative humidity(%) Cooling Nbisturedifference (gr/Ib) 88 Infiltration: 17 ( M) Nbthod 72 Construction quality 7.5 Fireplaces Heating Cooling 70 72 85 16 30 50 30.0 50.0 Simplified Semi -tight 1 (Semi -tight) Construction descriptions Or Area Ll -value Insul R Htg HTM Loss Clg HTM Gain 0.470 0 W Btuh/ft-°F ft'-'F/Btuh Btuh/fl' Bluh Bhh/lt' Bluh Walls 1115 21.8 60% 143 0.470 0 40.0 5698 12F-Osw: Frmwall, vnl ext, 1/2" wood shth, r-21 cav ins, 1/2" gypsumn 159 0.065 21.0 5.52 878 1.13 180 board int fnsh, 2"x6"wood fret 16" o.c. stud a 474 0.065 21.0 5.52 2619 1.13 538 50.0 s 422 0.065 21.0 5.52 2332 1.13 479 53 w 405 0.065 21.0 5.52 2237 1.13 459 all 1460 0.065 21.0 5.52 8066 1.13 1656 Partitions 12F-Osw : Frmwall, vnl ext, 1/2" wood shth, r-21 cav ins, 1/2" gypsum board intfnsh, 2'x6" wood frm, 16" o.c. stud Windows 4A5-2ov: 2 glazing, clr low -a outr, argon gas, insulated vinyl frm mat, e clr innr, i,2" gap, 1/4" thk; 6.67 ft head ht s w all Doors 11 DO: Door, wd sc type 11 P0: Door, mtl pur core type Callinf1ggs 161-56ad: Attic ceiling, asphalt shingles roof Trot, r-50 ceil ins, 5/8" gypsum board int fnsh C part ceiling,: C part ceiling, carpet flr fnsh, frm flr, 12" thkns, 5/8" gypsum board int fnsh Floors (none) 291 0.065 21.0 5.52 1608 0.65 190 170 0.470 0 40.0 6772 36.3 6160 28 0.470 0 40.0 1115 21.8 60% 143 0.470 0 40.0 5698 36.3 5184 340 0.470 0 40.0 13584 35.2 11953 e 24 0.390 0 33.1 796 11.2 268 s 24 0.390 0 33.1 796 11.2 268 w 24 0.390 0 33.1 796 11.2 268 n 24 0.390 0 33.1 796 11.2 268 all 96 0.390 0 33.1 3182 11.2 1073 w 96 0.290 10.5 24.6 2366 8.31 798 577 0.020 50.0 1.70 980 1.04 602 3 0.216 1.0 18.3 53 11.2 33 wrightaoft• 2022 -Dec -201108:49 .....,...., ..,., Rg ht-Suile®Universal 202222.0.01 RSU64702 Page ��...echt\Documents\W right soft H VAC\HBT-Ploeg er.mp Calc =Mf8 Front D oor faces: E wrightsoft Component Constructions pate: 9112122 Room4 By: Silver Tree Plumbing and Heating LLC 1335 Mendota Heights Rd, Mendota Heights, MN 55120 Phone: 651-319-4200 Email andyf@silvertreepandh.com Web: wvrvv.silvertreepandh.com For: HBT- Ploeger Residence Location: Mnneapolis-St Paul Intl, MV, US Elevation: 872 ft Latitude: 45°N Outdoor: Heating Drybulb (°F) -15 Dailyrange (°F) Wet bulb (°F) Wind speed (mph) 15.0 Heating Indoor: 70 Indoor temperature (°F) 85 Design TD (°F) 30 Relative humidity(%) Cooling tvbisturedifference (gr/lb) 88 Infiltration: 17 ( M) Nbthod 72 Construction quality 7.5 Fireplaces Heating Cooling 70 72 85 16 30 50 30.0 50.0 Simplified Semi -tight 1 (Semi -tight) Construction descriptions Or Area W Ll -value Btuh4P-°F Ins ul R fit-°FBtuh Htg HTM Btuh/fF Loss Clg HTM BWh 6tuh/W Gain Btuh Walls 12F-Osw : Frmwall, vnl ext, 1/2" wood shth, r-21 cav ins, 1/2" gypsumn 283 0.065 21.0 5.53 1562 1.13 321 board intfnsh, 2x6" w ood frm 16" o.c. stud a 331 0.065 21.0 5.52 1828 1.13 375 s 263 0.065 21.0 5.53 1450 1.13 298 w 209 0.065 21.0 5.52 1154 1.13 237 all 1085 0.065 21.0 5.52 5994 1.13 1231 Partitions (none) Windows 4A5-2ov: 2 glazing, clr !ow -e oulr, argon gas, insulated vinyl firm mat, a 161 C S 10 0 40.0 6412 36.3 5833 clr innr, 1/2" gap, 1/4" thk; 6.67 ft head ht s 20 0 4 '0 0 40.0 805 21.8 440 NY 126 JA :i r. 40.0 5052 36.3 4596 all 307 0.470 0 40.0 12270 35.4 10869 Doors (none) Ceilings 16B-50ad: Attic ceiling, asphalt shingles roof mat, r-50 ceil ins, 5/8" 1597 0.020 50.0 1.70 2715 1.04 1666 gypsum board int fnsh floors (none) _ -r- Wrilg~tsio-ft" Right Re® Universal 202222.0.01 RSU64702 2022-13-2011:08:49 Page 5 ACCK ... echt\Documents\W right soft HVAC\HBT- Ploeg er.rup Calc = M78 Front Door faces: E Component Constructions Job. wrightsoft p Date: 9/12/22 Rooms By: Silver Tree Plumbing and Heating LLC 1335 Mendota Heights Rd, Mendota Heights, MN 55120 Phone. 651-319-4200 Email: andyf@silvertreepandh.corn Web: wvr 1vertreepandh.corn For: HBT- Ploeger Residence Location: Or Indoor: Heating Cooling Mnneapolis-St Paul Inti, MJ, US Loss Clg HiM Indoor temperature (°F) 70 72 Elevation: 872 ft Btuh/R F Design TD (°F) 85 16 Latitude: 45°N Btuh Relative humidity(%) 30 50 Outdoor: Heating Cooling I\bisture difference (gr4b) 30.0 50.0 Dry bulb (T) -15 88 Infiltration: 89 0.065 Dailyrange (°F) 17 ( M) IVhthod Simplified 100 Wetbulb(°F) - 72 Construction quality Semi -tight 21.0 Wind speed (mph) 15.0 7.5 Fireplaces 1 (Semi -tight) Construction descriptions Or Area U -value Insul R Htg HTM Loss Clg HiM Gain fl' Btuh/R F ft'-'F/Btuh Btuh/R' Btuh Btuh/ft' Btuh Walls 12F-Osw: Frm wall, vnl ext, 1/2" wood shth, r-21 cav ins, 1/2" gypsumn 89 0.065 21.0 5.52 489 1.13 100 board intfnsh, 2"x6" wood frrn 16" o.c. stud s 89 0.065 21.0 5.52 489 1.13 100 w 176 0.065 21.0 5.52 970 1.13 199 all 353 0.065 21.0 5.52 1948 1.13 400 Partitions (none) Windows (none) Doors (none) Ceilings 16B-50ad: Attic ceiling, asphalt shingles roof mat, r-50 ceil ins, 5/8" 190 0.020 50.0 1.70 323 1.04 198 gypsum board int fnsh Floors (none) wrighttsOf - 2022 -De 2011:08:49 Right -Suite® Universal 202222.0.01 RSU64702 Page ACCK ... echt\Documents\Wdghtsoft HVAC\HBT- Ploeger. rup Calc = M18 Front Door faces: E wrightsoft• Right -A@ Form A Job: Entire House Date: 9/12122 Silver Tree Plumbing and Heating LLC 1335 Mendota Heights Rd, Mendota Heights, MN 55120 Phone: 651-319-4200 Email: andyf@silvertreepandh.com Web: www.silvertreepandh.com 1 Name of Room Room5 2 Running Feet of Exposed Wall 39.2 ft 3 Ceiling Ht (Ft) and Gross Wall Area (SgFt) 9.0 ft 528.0 ft' 4 Room Dimensions (Ft) and Floor Plan Area (SgFI) 1.0 x 190.2 ft 190.2 ft - 5 Ceiling Slope (Deg.) and Gross Ceiling Area (SgFt) 0 190.2 ft' Type of Const., Panel HTM I Area or I Btuh I Area or I Btuh Exposure Number FacesLength Length Htg. CIg. Heating S-Clg L-Cig Heating S-Clg L-Cig 6 Wall 12F-0sw n 5.52 1.13 89 489 100 Wall 15B-10s3o-6 n 6.16 0.28 0 0 0 all 12F-Osw a 5.52 1.13 0 0 0 laz 4A5-2ov a 39.95 36.34 0 0 0 11 r 11DO a 33.15 11.17 0 0 0 Wall 15B-10s3o-6 a 6.16 0.28 0 0 0 all 12F-0sw s 5.52 1.13 89 489 100 I_ 4A5-2ov s 39.95 21.84 0 0 0 or 11DO s 33.15 11.17 0 0 0 Wall 15B-10s3o-6 s 6.16 0.28 0 0 0 w 5.52 1.13 176 970 199 laz 4A5-2ov w 39.95 36.34 0 0 0 �12F-Osw .r 11DO w 33.15 11.17 0 0 0 oor 11 PO w 24.65 8.31 0 0 0 Wall 15B-10s3o-6 w 6.16 0.28 0 0 0 aIW I 12F-0sw - 5.52 0.65 0 0 0 Door 11DO n 33.15 11.17 0 0 0 Cad 16B-50ad - 1.70 1.04 190 323 198 Ceil 16MOad - 1.70 1.04 0 0 0 Ceil C part ceiling, - 18.33 11.25 0 0 0 Flor 21A -24t - 2.13 0.00 0 0 0 Infiltration Heating Load (Btuh) 0.27 1352 Effect WAR I I 122 I I I I 12 I Sensible Load (Btuh) I ACH 0.08 I 0.13 f -T Latent Load (Btuh) Internal a Occupants at 230 and 200 Btuh 0 0 0 b Scenario number 0 13 c Default Adjustments d Custom Appliances 0 0 e Plants 0 14 I Subto� ta; Is I Sum lines 6 through 12 I I 3622 I 714 Duct EH LF 8 ESGF 0 0 0 0 15 Loads ELG 0 16 Ventilation Loads Vent Cfm 0 E Cf. 0 17 I Winter Humidification Load Gal/Day I 10.5 I I I I I I I I r 18 Piping Load 19 Blower Heat 20 AED Excursion 8 Latent Moisture Migration Load -6 21 Total Load Sum lines 13 through 19 3622 714 Calculations aDDroved bvACCAtO meetall reauirements of Wnual J 8th Ed. -r}r- wrlyf.ltzoTc- 2022 -Deo -2011:08:49 --- -- - Right-Sude® Universal 2022 22.0.01 RSU64702 Page ...echt\Documents\W right soft HVAC\HBT- Ploeger. rup Calc =M18 Front D oor f aces: E CERTIFICATE OF SURVEY 3:1 MAX. SLOPES OR < \\ RETAINING WALL REQUIRED f \\\ INSTALL PERIMETER CONTROL `\v, N89'51'14"E / FIRST FLOOR ELEVATION - 936.71 TOP OF BLOCK - VARIES BASEMENT FLOOR ELEVATION - 926.15 I I Legal Description (Tax Description) I I Lot 2, Block 1, MORONI ADDITION, Dakota County, Minnesota. •------------t--------SANITARY SEWER MANHOLE RI =93912 INV -924.72, FIELD VERIFY I (RECORD DRAWINGS) I� 90 . I A2 ao• ouc 150.00 § 3 l«n lar as oa lea x�oee- az. or pxn m o, lY z m 926 91H 950 932 irx wv I IRON PIPE 3/4 INCH LOCATED- r f I u bb wy au'.aoal`2wnrr NAUV00 LANE 0.46 NORTH AND 0.29 EAST 2a•Mz t\ u• o x r, m s+z -Far wm w RIGHT-OF-WAY) BENCHMARK: nae , (60 F y eM,xaus oelwwAr SANITARY SEVER MANHOLE a lL °• pwt C mxu¢ e b yi fix l` — _ ----- RIM -941.00 ASSUMED T NIDE RIGHT OF WAY) _ IRON PIdE N89'51�14"E INV -923.78, FIELD VERIFY r a nt.mz11�6 xnaa a-�n,fr svzucr ° t 3/41NC 1-�-•�----��-lY _-_-__-_- _- xwr zwm wr y R'." (RECORD DRAWINGS) z nor \►a' "77' .eiaw °. a,Wnu¢ Y BENT e 1 � t, ! aS4�.'JTJ��=�,�-�xua ������° • w.. 10 FT NIDE DRAINAGE---- ,a --- �• � p.�w� zun wp 1 3/ I AND UTILITY EASEMENT " ^•a d; i5 m, Y- (TYPICAL) D I tr oAlt nm r oAz R< 0• °m e t y, wsv 'p fl F IT e: aa• one <1$0'00 1� d�' y� x "'. i x.nm �' o a tr au ,vl 0 ♦ t, d z.n.o " "ikr \ •` m1n" 9D • n� � r-- Wp� IL' oelt QT x.l,ua 1 a xn,ss • ." :nxe n a'P _ ` _ ♦ r ' _ r a �tmsuax.,m 6 x -- =------------ -- _ _ nae. �'�'-920-__ ` ( ___z nzw" ' s< - ♦* �'� .na _ __ __ `______ ____ ___y _ , _____________IT __ _____ ��' ;� nue ��'° i - K � eans"aa,a 1 l ♦ yt 4,em _ w.0 o m 1___�.�_ ____ _Y\_ �_c____ az,________ __ __ _ T_`_ � _ �„� � l ` • �/!°i0m RA• r �� mA �� P - O < \ 2 � 9 °`` f / to• ONO 8 x ` 1 BLOCK 1 a 10' Z n, x a I w mNp OY .nom N, n a(� 77a" ylt nr _ _ s wa 111 l r �llx r" YA. G - - _ 3 do L az tr ant e( i wtr tarnnteouwt s,r Ir orx:r t'+u zu, - _ _z ```s1 z_«..,_e'_� _ - �o�rr,11i11 � �.'m xalx- x ♦ _ _ vxa0.'~a. _ II1`_ xaIT lm• A L_jpan NSTALL RETAINING WALLS SOUTH SIDES OF PROPOSED RETAINING WALLS. MATCH PPOSD GRADES ON NORTH AND --T p In I L 1 J nem -+aL o`t RETAINING W e z / w ,♦♦ tr x cnr 1 z wm x nut _ _ _ _ _ _ rA. ll d� m' �1 I 1 FIEVATI u¢ '♦ seats¢ l` ^� : l: h to aa• out " _ m ` ♦rr .``-}- nsts .ar m I —.n—,v --fi— Qfi—a ^—A1Ea i•fi—s —pR- -ySr — Ma —fiY fi—a•�— —fie—:—ti6d° «A mB �— —e9 �'i }1 •�b v—dl. }�a 1r b �..--_ t, m—� �t'yyd yto o 9m24nN—T� ��, mzn4Xn41'—wlr _ «"S _ "— ''°w4_,_—__a—�-A •` n—I'1°x— — —gS-1 lI — - — —1I —�— —F —R—.I �—d4,m T6 —5—�-5�—`—I 9�—n__—RjH,_a--a—s—rl—a?I —---�-- _— --91Q—�z� o a ---SANITAIRY S EWER MA NHO LE/ CHIRON PIPE J IRON P7E I dRIM-934.73 isF INV -923.43, FIELD VERIFY (RECORD DRAWINGS)o m.me w= le 139 \ —34 a 1- F er j STORM SEWER MANHOLE IM:934.34 9711 b wti ♦ P zen oti a e i pre :anrr°v� INV -927.48, FIELD VERIFY (RECORD DRAWINGS) ~ I I 703.66 I r J ora I I I s89'53.34"w I =C I I I �O� I I I (PUT 703.65) L E G E N D I �' O Denotes 12 Inch Common Spike set with 3 washer stamped RLS 16464or as noted. L\/I \ - 1 Denotes Iron Monument found - size, type, $ R.L.S. as noted. I I / \ I I I \ \ I V oL_ _ ® Denotes Proposed Spot Elevation —X:-- Denotes Proposed Contours Denotes Proposed Drainage Direction • nppxx Denotes Existing Spot Elevation -m- Denotes Existing Contour 7t Denotes Hydrant ® Denotes Storm Sewer Manhole Cover m Denotes Sanitary Sewer Manhole Cover w Denotes Power Pole a Denotes Guy Anchor ® Denotes Utility Pedestal N Denotes Proposed Curb Stop Box TOW Denotes Top of Wall BOW Denotes Bottom of Wall —o— Denotes Safety Fence �— Denotes Underground Sanitary Sewer —w— Denotes Underground Water Service —� Denotes Under round Gas Line 7pD �L PROPOSED IMPERVIOUS AREAS HOUSE - 3441 q n TOTAL LOT AREA - 4 n 704 NAUV00 LANE, EAGAN, MN 55123 I TOTAL IMPERVIOUS PERCENTAGE - 2.4Y J GRAPHIC SCALE 9 SITE ADDRESS: 704 NAUV00 LANE, EAGAN, MN 55123 rw -a"•- Denotes Overhead Utility wires LOT AREA: 141,374 S0. FT. OR 3.25 ACRES Denotes Concrete Surface (N pgWy ) Aor Denotes Tree to be Removed 1 Le - 10 tr. Denotes Silt Fence --- Denotes Orange Tree Protection Fence pied MARCUS AND AUCIA PLOWER 710 MARSH COURT III* by DF Orlgbd date 03-03-22 I'""r�.r.. r-'. �'•'.. �:.'�i, I•nr-•+ it r,4 rrl-�rr�lrr s6 Dram by DF/RP Re"— 12-14-22 EAGAN, MN 55123 � F� ar 03-03-22 Irr y r 16164 LAKE AND LAND SURVEYING, INC. mayaw/cm 41001®IG IWD CEITIS PDIIM M S16 Spry book Na Page 1111, CERTIFICATE OF SURVEY S.AP.numba 2022.020 Sheet number of ST PAU4 III. 66129 PillI'll,'f76-6'tll &MAO: IDNALIY®TIALODN From:Sarah Foster To:Sally Cairns Subject:704 Nauvoo Ln-Size upgrade Date:Monday, April 10, 2023 2:36:25 PM Attachments:image001.png Hey Sally, I just wanted to give you a heads up on this one. We were our at 704 Nauvoo Ln for a meter install, they paid for a ¾’’ meter but wanted a 1inch (that’s the highest we will approve on this site). I talked to Brent and I believe he filled in Arlen for this approval. The plumbing company (Silver Tree Plumbing) was going to call in to pay the difference $80 is wat they will owe. If you need any more info please let me know. Thanks! Sarah FosterClerical IV3419 Coachman Pt | Eagan, MN 55122Office: 651-675-5210https://www.cityofeagan.com