Loading...
EA181296 - Building - Deck - Issued Date 02/22/2023I W D1 W31V r City of Eagan Permit Type: Building 3830 Pilot Knob Rd ®®®® ®a®®®°® Permit Number: EA181296 Eagan, MN 55122 ®-®® ®®-®EAGAN (651) 675-5675 111111111111 www.cityofeagan.com * E A 1 8 1 2 9 6 Date Issued: 2/22/2023 Site Address: 3660 Kolstad Rd Lot: 3 Block: 08 Addition: Timbershore PID:10-76500-08-030 Use: * 10-76500-08-030* Description: Sub Type: Deck Construction Type: V -B Work Type: Replace Description: replace existing deck Census Code: 434 - Residential Additions, Alterations Occupancy: IRC -3 Zoning: PD Square Feet: 0 Comments: Fee Summary: (BL) Plan Review $75.79 0801.4222 Valuation: 3,200.00 BL - Base Fee $116.60 0801.4085 Surcharge - Based on Valuation $2.00 9001.2195 Total: $194.39 'Contractor: - Applicantl - Owner: Infinite Floors and More Wardah Mirza Zaidi , 1 1310 Larc Industrial Blvd 503 Aidan Cv Burnsville MN 55337 Eagan MN 55123 (612) 702-6273 This permit shall be null and void if work does not start within 180 days of issuance, or if work is suspended for 180 days or more after• started. I hereby acknowledge that I have read this application and state that the information is correct and agree to comply with all applicable State of Minnesota Statutes and City of Eagan Ordinances. r, Applicant/Permitee:. Signature sued B : Signature g ECEIVE FEB 0 7 2023 0� Date: Site Address: Unit Applicant is: ❑ Owner ® Contractor EAGAN0 a Homeowner 3830 PILOT KNOB ROAD I EAGAN, MN 55122-1810 (651) 675-5675 1 FAX: (651) 675-5694 build incinspections(-citvofea4an.com 1rn31 il4 For Office Use `� I Building Permit #: (� I `� 0 I I I j S&W Permit #: I I Permit Fee: I I Date Received: l,�� 12� I I I I I I Date Issued: I---------------------- RESIDENTIAL BUILDING PERMIT APPLICATION 2-6-2023 3660 Kolstad RD . Sagan, MN 55123 #: Date: Site Address: Unit Applicant is: ❑ Owner ® Contractor Name: lC Homeowner Address: ;I D� CIISId(t. �lA. city: U� State: Zi : Phone: - '�'�3 Email: ki I . Description of work: Lplru. li 11d i Type of Construction Cost: ' ��lia D) i Iober�oR b Work Type of building: ❑ Single Family t Townhome, 1 of units ❑ Twin Home Company: S-rin[�(S �b(C Contact: �GlA �P Building Address: ���,d �.aCC. �;Ita, la� V City:li�S>tLl.e Contractor ,�p��( State: t \l Zip: Phone: 1X12 �l') �¢ Email: _k l)C License #: 1 5 Date: Sewer & —Expiration Company: Contact: Water Contractor Address: City: Required for State: Zip: Phone: Email: new construction License #: Expiration Date: .01 understand that Plumbing, Mechanical, and Fire Suppression work require separate applications. NOTE: Plans and supporting documents that you submit are considered to be public Information. Portions of the Information may be classified as non-public If you provide specific reasons that would permit the City to conclude that they are trade secrets. CALL BEFORE YOU DIG. Contact Gopher State One Call at (651) 454-0002 or www.aooherstateonecall.ora for protection against underground utility damage. Contact Gopher State One Call 48 hours before you Intend to dig to receive locates of underground utilities. I hereby acknowledge that this Information is complete and accurate; that the work will be in conformance with the ordinances and codes of the City of Eagan; that I understand this is not a permit, but only an application for a permit, and work is not to Ste ut a permit; that the work will be in accordance with the approved plan in the case of work which requires a review and approval of pla a� x ASA,i\ iIcm In Applicant's Printed Nalne SUB TYPES _ Single Family _ 01 of_ Plex Deck WORK TYPES _ New _ Addition _ Alteration Replace FOR OFFICE USE ONLY Site Address: 3660 Kolstad Lane Eagan, MN 55123 _ Fireplace _ Lower Level _ Foundation _ Porch _ Garage _ Pool _ Repair _ Siding _ Fire Repair _ Reroof _ Water Damage _ Windows _ Egress Window _ Solar DESCRIPTION Calculated Valuation $ 3,200 Plan Review 025% 00% Census Code # of Units # of Buildings Type of Construction VR Permit #: _ Retaining Wall _ Move Building _ Demolish Building* •DemoUtion of entire building. — give PCA handout to applicant occupancy IRC 3 MCES System Code Edition 2020 MN RC SAC Units Zoning PD City Water Stories Booster Pump Square Feet PRV Fire Suppression Required Separate Stormwater Management Permit Required RE UIRED INSPECTIONS Footings: New Addition Deck Foundation: Before Backfill Poured Wali Framing: 1 Hour -.Aesidential Alteration Braced Wall Framing/Blocking Braced Wall Sheathing -(prior to house wrap) Interior Braced Wall Panels) Firewalls Insulation Radon Control Drain Tile Grading 02-111-1, E Derek ChuaM 0211620231225:35 PM Meter Size: Siding: _Stucco Lath Stone Lath _BrIck Roof: _Ice & Water _Final Erosion Control Pool: _Footings Air/Gas Tests _Final Retaining Wall: _Footings _Backfill _Final Fire Suppression: _Rough In _Final Windows Other: Final/No C.O. Required Flnal/C.O.Required Reviewed By: NUUILU1"U1N muIlU"" . Building Inspector FEES Calculated Valuation Base Fee Plan Review State Surcharge Met Council SAC City SAC Treatment Plant Water Supply & Storage S&W Permit & Surcharge Meter Radio Read Other: $3,200 Replacing Deck with new $116.60 $75.79 $2.00 TOTAL $ 194.39 - 8x20 = 160sf 160sf x $20 = $3,200 Required Information for Deck Permits Fq a. CL 'o 4 B Lateral load connection: Beam to posts: B Post cap (manufacturer/model) ® Through bolts (size) ❑ Other approved type Joist to beam: B Joist hanger B Other B Any other hardware used: (5) - Simpson Strong Tie's N/A 1/2" x 8" Lag Bolts 2" x 10/12" MiTek Hangers Simpson Hurricane Clips #10 16D nails - #9 & #10 Smpson screws Final Checklstfor'Perfihit Submittal" Two (2) copies of plans that Include: REVIEWED FOR CODE COMPLIANCE ❑ cross section view ❑ Plan view 0 ❑ Stair framing view EAGAN Dere&0.00 ❑ Applicable supplemental information """' BUILDING INSPECTIONS Site plan, drawn to scale on survey or plat map, Including: ❑ Deck dimensions ❑ Distance to property tines ® Dimensions of deck: 8'x 20' ® Height of deck from ground: 5' ® Size of posts: 6" x 6" B spacing of posts: approx. 9' See Plan ® Footing diameter. 22- Handipier B Footing depth: 48" Pin - HandiPier HP -R (50) If sizes vary, leave blank and indicate individual sizes on plans. *4Y minimum for traditional concrete footing. Specify If using engineered footings 0.e., Dlambnd Pier) and provide Installation instructions. ® Size of beam(s): (2) - 2" x 10" B Drop or flush beam(s): Drop 'Example: 2 — T x 12' B Cantilever on beam(s): 1CL' c B Size of joists: 2" x 10" B Spacing of joists: 16" B Species of lumber for framing: AC2 Pressure Treated Pine B Dimensions of floorboards: 1-1/4" x 6" x 20' ® Floorboard type: AC2 Green Treated 1-1/4"x 6" Pine ® Pattern of floorboards: Perpendicular to joists *i.e: perpendicular (90 degrees) to joists, 30/45/or 60 degrees to joists ® Stair width: N/A ® Stair stringer spacing: N/A ® Stair length: N/A ❑ will the deck be built around a cantilevered area? (i.e., a bay with a patio door) YesNo ® What type of floor framing will the ledger be attached to? (i.e., [joist, floor truss, 2"x 10", etc.) 2" x 10" Distance to property lines: 3 B Side 1: Shared wall on quad unit B Rear. Shared wall B Side 2: Approx. 20' to shared driveway ❑ Other. c Type of hardware to be used: See Attachment for Ledger board: ledger fastener spacing ® Ledger board connection: Ledger Lock Bolts - 3per joist Fq a. CL 'o 4 B Lateral load connection: Beam to posts: B Post cap (manufacturer/model) ® Through bolts (size) ❑ Other approved type Joist to beam: B Joist hanger B Other B Any other hardware used: (5) - Simpson Strong Tie's N/A 1/2" x 8" Lag Bolts 2" x 10/12" MiTek Hangers Simpson Hurricane Clips #10 16D nails - #9 & #10 Smpson screws Final Checklstfor'Perfihit Submittal" Two (2) copies of plans that Include: REVIEWED FOR CODE COMPLIANCE ❑ cross section view ❑ Plan view 0 ❑ Stair framing view EAGAN Dere&0.00 ❑ Applicable supplemental information """' BUILDING INSPECTIONS Site plan, drawn to scale on survey or plat map, Including: ❑ Deck dimensions ❑ Distance to property tines