EA181192 - Building - Single Fam - Issued Date 03/02/2023City of Eagan
3830 Pilot Knob Rd
Eagan, MN 55122
(651) 675-5675
www.cityofeagan.com
PERMIT
Permit Type: Building
®®®®; ®� K Permit Number: EA181192
Site Address: 4014 Haven Woods Ct
Lot: 5 Block: 1 Addition:
PID:10-32090-01-052
Use:
Description:
Sub Type: Single Fain
Work Type: New
Description:
Census Code: 101- Single Family Houses
Zoning: R-1
Square Feet: 0
* E R 1 B 1 1 9 Z*
Date Issued: 3/2/2023
* 1 0— 3 2 0 9 0— 0 1— 0 S 2
Construction Type: V -B
Occupancy: IRC -1
Comments: Improvements to the home may require smoke detectors in all bedrooms.
Carbon monoxide detectors are required within 10 feet of all sleeping room openings in residential homes (Minnesota State
Building Code).
Fee Summary: 3/4" Meter
$300.00
6101.4509
Valuation: 341,907.00 BL - Base Fee
$2,820.15
0801.4085
BL - Plan Review 65%
$1,833.10
0720.4222
City SAC (01 Unit)
$139.00
9376.4681
Radio Read Unit (Domestic)
$240.00
6101.4509
Surcharge - Based on Valuation
$170.95
9001.2195
Surcharge -Fixed
$1.00
9001.2195
SW - Sewer Permit Fee
$80.00
6201.4532
SW - Water Permit
$80.00
6101.4507
Treatment Plant - Residential
$1,126.00
6101.4685
Water Supply & Storage
$1,812.40
6101.4680
SAC (1 unit) - Single Family House
$2,485.00
9220.2275
Total: $11,087.60
Contractor: - Applicant - Owner:
SD Custom Homes Dodd Residential LLC
750 Main Street 6800 York Ave S Apt 705
Suite 223 Edina MN 55435
West St. Paul MN 55118
permit shall be null and void if work does not start within 180 days of issuance, or if work is suspended for 180 days or more after
hereby acknowledge that I have read this application and state that the information is correct and agree to comply with all applicable State
f Minnesota Statutes and City of Eagan Ordinances.
Applicant/Permitee: Signature
ssued B : Signature
-------------�
For Office Use I
�4�ltIa.
I Building Permit #: 1
I ' Ll0[
EA
Si3<WPermit
MW
#: b
E %j I
Permit Fee: I r / 08 7�•
Date Received: i 131 23 I
3830 PILOT KNOB ROAD I EAGAN, MN 55122-181G
(651) 675-5675 1 FAX: (651) 675-5694 ` ` 1 Date Issued:
buildinainspectionsCa-citvofeaaan.cam R8 Y
Y, l — — — — — — — — — — -- — — — — — — — — —
.U
RESIDENTIAL BUILDING PERMIT APPLICATION
Date: 1-30-2023 Site Address: 4014 Haven Woods Court unit #:
Applicant is: ❑ Owner 14 Contractor �--1 W-0e,
Name:
Camile Abrams
Address: 3616 Ridge Drive �;,; Eagan
MN 55123camiIleabrams@gmail.com
Fa
State: zip:Phone: Email:
Description of work: New Home
�y;o . .° 700,000.00
Construction Cost:
Type of building: Single Family ❑ Townhome, of units ❑Twin Home
SD Custom Homes Sean Doyle
Company: Contact: Y
z `iuitng Address: 750 Main Street, Suite 223 City:Mendota Heights
�''nr�tc>1ar Y MN 55118 651-994-3991 sean@sd-customhomes.com
State: zip: Phone: Email:
�BC 637953
License #: Ex iration Date:
Voehl Excavating Jer Voehl
nrL+ Company: Contact: ry
,,'F Po Box 296 Prior Lake
�itract� Address: city:
i2equired for state: MiV zip: 55372 Phone: 612-819-8261 Email: jvoehleXc@gmail.com
new,radE��truct��n. a
License #: Expiration Date:
I understand that Plumbing, Mechanical, and Fire Suppression work require separate applications.
,yR Piafts °arid supra tfrtg dict►tt�ehts'that you submit are cs�nsiired tt!'bE3 public titfdi'ttatioti. ,lorfidri of thy;'
i�f# �tiurt tinaya;be clss�lfled a� ftatt��i�b�lc��fydu p��rrlde sp�itta r�o%ts #h;�tw�uid;pa�r»itthe alto tc cc�nclud� thatpttrey
CALL BEFORE YOU DIG. Contact Gopher State One Call at (651) 454-0002 or www.aopherstateonecall.om for protection against underground utility
damage. Contact Gopher State One Call 48 hours before you intend to dig to receive locates of underground utilities.
I hereby acknowledge that this Information Is complete and accurate; that the work will be in conformance with the ordinances and codes of the City of
Eagan; that I understand this is not a permit, but only an application for a permit, and work is not to start without a permit; that the work will be in
accordance with the approved plan In the case of work which requires a review and approval of plans.
X Sean Doyle x
Applicant's Printed Name Applicant's Signatuiff
Site Address: 4014 Haven Woods Court
SUB TYPES
MCES System x
Code Edition
�( Single Family
_ Fireplace
_ Lower Level
_ 01 of _ Plex
_ Foundation
_ Porch
Deck
_ Garage
_ Pool
WORK TYPES
Management Permit Required
164- LevcA - 1-46 X `i5. ` ,3 s
New
_ Repair
_ Siding
_ Addition
_ Fire Repair
_ Reroof
_ Alteration
_ Water Damage
_ Windows
Replace
_ Egress Window
_ Solar
DESCRIPTION 3y� p7.
Calculated Valuation
Plan Review 025% 1W%
Census Code
# of Units
# of Buildings
Type of Constructiony!—
Permit #:
_ Retaining Wall
_ Move Building
_ Demolish Building*
*Demolition of entire building — give PCA
handout to applicant
Occupancy
MCES System x
Code Edition
SAC Units 1
Zoning
City Water
Stories
Booster Pump
Square Feet
PRV
LL F"nj s~ - I q 79 X T5•-73 "
Fire Suppression Required
Separate Stormwater
Management Permit Required
REQUIRED INSPECTIONS
X Footings: K New Addition Deck
f Foundation: X Before Backfill ? Poured Wall
YC Framing: J1 Hour Residential Alteration
Braced Wall Framing/Blocking
C Braced Wall Sheathing (prior to house wrap)
Interior Braced Wall Panel(s)
Firewalls
Insulation
C Fireplace: X Rough In Air Test A Final
HVAC: Rough In Final
Meter Size:
K Siding:_4_Stucco Lath )K Stone Lath _Brick
Sr Roof: Y, Ice & Water Final
Erosion Control
Pool: _Footings Air/Gas Tests _Final
Retaining Wall: _Footings _Backfill _Final
Fire Suppression: _Rough In _Final
A Windows
Other:
Y Radon Control
X Drain Tile
Reviewed By: �S(�S�
f/,
,
Final/No C.O. Required
Final/C.O. Required
Building Inspector
FEES
SSrw' '
Calculated Valuation
-314) ! q ®%, 11
LL F"nj s~ - I q 79 X T5•-73 "
142,73-S .4 3
Base Fee
164- LevcA - 1-46 X `i5. ` ,3 s
1(pq 127Z. (08
Plan Review
&.a. "e, - 409 f X qo•w =
0P71 (0110
vetl(l- yt% X Z�D
$� -
State Surcharge
�bri✓h 17-
jiZ,City
Met Council SAC
CitySAC
Treatment Plant
Water Supply & Storage
T®tom
S&W Permit & Surcharge
Meter
Radio Read
Other:
TOTAL $ 0.00
New Construction Energy Code Compliance Certificate
Per R401.3 Certificate. A buliding certificate shall be posted on or in the electrical distribution Date CertlticatE
panel.
Mailing Address of the Dwelling or Dwelling Unit
RADON CONTROL SYSTEM
City
4014 Wood Haven Ct
MECHANICAL VENTILATION SYSTEM
Eagan
Name of Residential Contractor
Combustion Air Select a Type
MN License Number
Cr) Pnefnm I-Inmae
Apply
RCR17953
AIR MECHANICAL.
THERMAL ENVELOPE
RADON CONTROL SYSTEM
" round dud OR
MECHANICAL VENTILATION SYSTEM
Type:
Check
Combustion Air Select a Type
All That
Passive
Apply
X Other, describe:
Passive (No Fan)
Location of duct or system:
FLEX MECH ROOM
x Balanced Ventilation capacity In dms: I 190 crm
Location of fan(s), describe:
Cfm's
x Capacity continuous ventilation rate In cfms: 90 cfm on lowspeed
° FLEXOR
d)
"metal dud
Active (With fan and monometer or
o
other system m onflorinly device )
ar,
Location or future location) of Fan:
C3
E
a°
m
a
Q
m
m
Insulation Location
Z
$
m
m
U
p
u
�i�777iii
�,hZ
I
M
a
W
Other Please Describe Here
Below Entire Slab
Foundation Wail
JR
XPerimeter
of Slab on Grade
Rim Joist(Ist Floor
X
Rim Joist 2nd Floor+)
Wan
Ceilin , flet
-50
Gelling, vaulted
Bav Windows or cantilevered areas I R-30
Floors over unconditioned area
Describe other Insulated areas
Building envelope air tightness:
Windows & Doors
Average U -Factor (excludes skylights and one door) U: 10.31
Solar Heat Gain Coefficient (SHGC): 10.31
MECHANICAL SYSTEMS
Appliances Heating SystemDi
FuelType Natural as
Manufacturer BRYANT
I Duct system airtightness: I Less than 160 cfm
Heating or Cooling Ducts Outside Conditioned Spaces
Not applicable, all ducts located in conditioned space
R -value
Make-up Air Select a Type
testic Water Cooling System
Heater X I Not required per meth. code
Interlocked with exhaust device.
Model 912SD48080 BA13NA036 Describe:
Input in ,'00�In
pacity Output Other, describe:
113TUS: Gallons: 50 in Toni
or
or 1 92011 ISEER 1 1311 Location of dud or
Residential Load Calculati Heating Loss He Gain Cooling Load
1340(F
Cfm's
" round dud OR
MECHANICAL VENTILATION SYSTEM
-metal dud
Describe any additional or combined heating or cooling systems If installed: (e.g. two furnaces or air
source heat pump with gas back-up furnace):
Select Type BROAN HRV IOOT BALANCED
Combustion Air Select a Type
Not required per mach. code
Passive
X Heat Recover Ventilator HR Capacity in cfms: Low High:
X Other, describe:
Energy Recover Ventilator (ERV)Capacity in cfms: ILow. I 11-Ilgh: I
Location of duct or system:
FLEX MECH ROOM
x Balanced Ventilation capacity In dms: I 190 crm
Location of fan(s), describe:
Cfm's
x Capacity continuous ventilation rate In cfms: 90 cfm on lowspeed
° FLEXOR
_. Total ventilation (intermittent + continuous) rate in cfms: 180 dirt
"metal dud
Builders Assodaton of Minnesota version 101014
Ventilation, Makeup and Combustion Air
Calculations Submittal Form For New
Dwellings
Site address
4014 Haven Woods Ct I Date 1/26/23
Contractor
SD Custom Homes
Completed By
140
Section A
Ventilation Quantity
(Determine quantity by using Table N1104.2 or Equation 11-1)
Square feet (Conditioned area including basement—
finished or unfinished)
—
* ,-- '
Total required ventilation
140
3
70
Number of bedrooms
Continuous ventilation
Directions - Determine the total and continuous ventilation rate by either using Table N1104.2 or equation 11-1.
The table and equation are below.
Table N1104.2
Total and Continuous Ventilation Rates in cfm
Number of Bedrooms
1
2
3
4
5
6
Conditioned space
(in sq. ft.)
Total/
continuous
Total/
continuous
Total/
continuous
Total/
continuous
Total/
continuous
Total/
continuous
1000-1500
60/40
75/40
90/45
105/53
120/60
135/68
1501-2000
70/40
85/43
100/50
115/58
130/65
145/73
2001-2500
80/40
95/48
110/55
125/63
140/70
155/78
2501-3000
90/45
105/53
120/60
135/68
150/75
165/83
3001-3500
100/50
115/58
130/65
145/73
160/80
175/88
3501-4000
110/55
125/63
1 140/70
155/78
170/85
185/93
4001-4500
120/60
135/68
150/75
165/83
180/90
195/98
4501-5000
130/65
145/73
160/80
175/88
190/95
205/103
5001-5500
140/70
155/78
170/85
185/93
200/100
215/108
5501-6000
1 150/75
165/83
180/90
195/98
1 210/105
1 225/113
Equation 11-1
(0.02 x square feet of conditioned space) + [15 x (number of bedrooms + 1)] = Total ventilation rate (cfm)
Total ventilation — The mechanical ventilation system shall provide sufficient outdoor air to equal the total ventilation rate
average, for each one-hour period according to the above table or equation. For heat recovery ventilators (HRV) and
energy recovery ventila- tors (ERV) the average hourly ventilation capacity must be determined in consideration of any
reduction of exhaust or out outdoor air intake, or both, for defrost or other equipment cycling.
Continuous ventilation - A minimum of 50 percent of the total ventilation rate, but not less than 40 cfm, shall be provided,
on a continuous rate average for each one-hour period. The portion of the mechanical ventilation system intended to be
continuous may have automatic cycling controls providing the average flow rate for each hour is met.
Section B
Ventilation Method
Choose either balanced or exhaust
F1 Balanced, HRV (Heat Recovery Ventilator) or ERV (Energy
0 Exhaust only (Continuous fan rating in cfm)
Recovery Ventilator) — cfm of unit in low must not exceed
continuous ventilation rating by more than 100%.
Low cfm:
80High
cfm:
1 60
Continuous fan rating in cfm (capacity must not exceed
continuous ventilation rating by more than 100%)
Directions - Choose the method of ventilation, balanced or exhaust only. Balanced ventilation systems are typically HRV or
ERV's. Enter the low and high cfm amounts. Low cfm air flow must be equal to or greater than the required continuous
ventilation rate and less than 100% greater than the continuous rate. (For instance, if the low cfm is 40 cfm, the ventilation
fan must not exceed 80 cfm.) Automatic controls may allow the use of a larger fan that is operated a percentage of each
hour.
Section C
Ventilation Fan
Description Location Continuous Intermittent
Broan HRV 160T Mach Room
Directions - The ventilation fan schedule should describe what the fan is for, the location, cfm, and whether it is used for
continuous or intermittent ventilation. The fan that is chosen for continuous ventilation must be equal to or greater than the
low cfm air rating and less than 100% greater than the continuous rate. (For instance, if the low cfm is 40 cfm, the
continuous ventilation fan must not exceed 80 cfm.) Automatic controls may allow the use of a larger fan that is operated a
percentage of each hour.
Section D
Ventilation Controls
Directions - Describe operation and control of the continuous and intermittent ventilation. There should be adequate detail for plan
reviewers and inspectors to verify design and installation compliance. Related trades also need adequate detail for placement of controls
and proper operation of the building ventilation. If exhaust fans are used for building ventilation, describe the operation and location of any
controls, indicators and legends. If an ERV or HRV is to be installed, describe how it will be installed. If it will be connected and interfaced
with the air handling equipment, please describe such connections as detailed in the manufactures'installation instructions. If the
installation instructions require or recommend the equipment to be interlocked with the air handling equipment for proper operation, such
interconnection shall be made and described.
Makeup Air for Exhaust Appliances
(determined from calculations from MN Minnesota Mechanical Code, Table 501.4.1)
❑ Passive TO Powered FIT Interlocked with exhaust device
Other, describe: Not Required
Location of duct or system ventilation makeup air
(Determined from make-up air opening table, Table 501.4.2.)
ONE OR MULTIPLE FAN-
cfm
MULTIPLE APPLIANCES
Size and type (round, rectangular, flex or rigid)
POWER VENT OR DIRECT
Directions - In order to determine the makeup air for ventilation, use Table 501.4.1. For most new installations, column A will be
appropriate, however, if kitchen hoods exceed 300 cfm, atmospherically vented appliances or solid fuel appliances are installed, use
the appropriate column. Please note, if the makeup air quantity is negative, no additional makeup air will be required for
ventilation, if the value is positive refer to Table 501.4.2 and size the opening. For existing dwellings, see IMC 501.4.3.
TABLE 501.4.1
PROCEDURE TO DETERMINE MAKEUP AIR QUANTITY FOR EXHAUST APPLIANCES IN DWELLINGS
ONE OR MULTIPLE
ONE OR MULTIPLE FAN-
ONE ATMOSPHERICALLY
MULTIPLE APPLIANCES
POWER VENT OR DIRECT
ASSISTED APPLIANCES
VENTED GAS OR OIL
THAT ARE
VENT APPLIANCES OR
AND POWER VENT OR
APPLIANCE OR ONE
ATMOSPHERICALLY
NO COMBUSTION
DIRECT VENT
SOLID FUEL APPLIANCE c
VENTED GAS OR OIL
APPLIANCES a
APPLIANCES b
APPLIANCES OR SOLID
FUEL APPLIANCES a
1. Use the Appropriate Column to Estimate House Infiltration
a) pressure factor (cfm/sf)
0.15
0.09
0.6
0.03
b) conditioned floor area
(sf) (including unfinished
3804
basements)
Estimated House Infiltration
570
(cfm): [la x 1b]
2. Exhaust Capacity
a) clothes dryer
135
135
135
135
b) 80% of the largest
240
exhaust rating (cfm):
(not applicable if recirculating system or if powered makeup air is electrically interlocked and matched to exhaust)
c) 80% of the next largest
Not
exhaust rating (cfm):
Applicable
(not applicable if recirculating system
or if powered makeup air is electrically interlocked and matched to exhaust)
Total Exhaust Capacity (cfm):
.41
.41
.59
10.7
[2a + 2b + 2c]
3. Makeup Air Requirement
a) Total Exhaust Capacity
375
(from above)
b) Estimated House
570
Infiltration (from above)
Makeup Air Quantity (cfm):
-195
[3a - 3b]
(if value is negative, no makeup air is needed)
4. For Makeup Air Opening Sizing, refer to Table 501.4.2
a. Use this column if there are other than fan -assisted or atmospherically vented gas or oil appliances of if there are no
combustion appliances.
b. Use this column if there is one fan -assisted appliance per venting system. Other than atmospherically vented appliances may
also be included.
C. Use this column if there is one atmospherically vented (other than fan -assisted) gas or oil appliance per venting system or on
solid fuel appliance.
d. Use this column if there are multiple atmospherically vented gas or oil appliances using a common vent or If there are
atmospherically vented gas or oil appliances and solid fuel appliances.
Makeup Air Opening Table for New and Existing Dwelling
Table 501.3.2
Notes:
A. An equivalent length of 100 feet of round smooth metal duct is assumed. Subtract 40 feet for the exterior hood and ten feet for each 90 -
degree elbow to determine the remaining length of straight duct allowable.
B. If flexible duct is used, Increase the duct diameter by one inch. Flexible duct shall be stretched with minimal sags. Compressed duct shall
not be accepted.
C. Barometric dampers are prohibited in passive makeup air openings when any atmospherically vented appliance is installed.
D. Powered makeup air shall be electrically interlocked with the largest exhaust system.
Section F
Combustion
0 Not required per mechanical code (No atmospheric or power vented appliances)
0 Passive (see IFGC Appendix E, Worksheet E-1) Size and type 6" INSULATED FLEX
M Other, describe:
Explanation - If no atmospheric or power vented appliances are installed, check the appropriate box, not required. If a
power vented or atmospherically vented appliance installed, use IFGC Appendix E, Worksheet E-1 (see below). Please
enter size and type. Combustion air vent supplies must communicate with the appliance or appliances that require the
combustion air.
Section F calculations follow on the next 2 pages.
4
One or multiple power
One or multiple fan-
One atmospherically
Multiple atmospherically
vent, direct vent
assisted appliances and
vented gas or oil
vented gas or oil
Dud
appliances, or no
power vent or direct
appliance or one solid
appliances or solid fuel
diameter
combustion appliances
vent appliances
fuel appliance
appliances
Column A
Column B
Column C
Column D
Passive opening
1-36
1-22
1-15
1-9
3
Passive opening
37 —66
23-41
16-28
10-17
4
Passive opening
67-109
42-66
29-46
18-28
5
Passive opening
110-163
67-100
47-69
29-42
6
Passive opening
164 —232
101-143
70-99
43-61
7
Passive opening
233 —317
144-195
100-135
62-83
8
Passive opening
w/motorized damper
318 —419
196 —258
136-179
84-110
9
Passive opening
w/motorized damper
420 —539
259— 332
180 —230
111-142
10
Passive opening
w/motorized damper
540— 679
333— 419
231— 290
143-179
11
Powered makeup air
>679
>419
>290
>179
NA
Notes:
A. An equivalent length of 100 feet of round smooth metal duct is assumed. Subtract 40 feet for the exterior hood and ten feet for each 90 -
degree elbow to determine the remaining length of straight duct allowable.
B. If flexible duct is used, Increase the duct diameter by one inch. Flexible duct shall be stretched with minimal sags. Compressed duct shall
not be accepted.
C. Barometric dampers are prohibited in passive makeup air openings when any atmospherically vented appliance is installed.
D. Powered makeup air shall be electrically interlocked with the largest exhaust system.
Section F
Combustion
0 Not required per mechanical code (No atmospheric or power vented appliances)
0 Passive (see IFGC Appendix E, Worksheet E-1) Size and type 6" INSULATED FLEX
M Other, describe:
Explanation - If no atmospheric or power vented appliances are installed, check the appropriate box, not required. If a
power vented or atmospherically vented appliance installed, use IFGC Appendix E, Worksheet E-1 (see below). Please
enter size and type. Combustion air vent supplies must communicate with the appliance or appliances that require the
combustion air.
Section F calculations follow on the next 2 pages.
4
Directions - The Minnesota Fuel Gas Code method to calculate to size of a required combustion air opening, is called the Known Air
Inriltration Rate Method. For new construction, 4b of step 4 is required to be Wed out.
IFGC Appendix E, Worksheet E-1—Residential Combustion Air Calculation Method for Furnace, Boiler, and/or Water Heater in the Same Space)
Step 1: Complete vented combustion appliance information.
Furnace/Boiler.
Draft Hood 0 Fan Assisted 0 Direct Vent input: 80000 Btu/hr
or Power Vent
Water Heater.
ODraft Hood FL] Fan Assisted Q Direct Vent Input 55000 Btu/hr
or Power Vent
Step 2: Calculate the volume of the Combustion Appliance Space (CAS) containing combustion appliances. The CAS includes all
spaces connected to one another by code compliant openings.
CAS volume: 1728 ft3 L x W x H L W H
Step 3: Determine Air Changes per Hour (ACH)l
Default ACH values have been Incorporated into Table E-1 for use with Method 4b (KAIR Method).
If the year of construction or ACH is not known, use method 4a (Standard Method).
Step 4: Determine Required Volume for Combustion Air. (DO NOT COUNT DIRECT VENT APPLIANCES)
4a. Standard Method _ _
Total Btu/hr input of all combustion appliances Input: ��� Btu/hr
Use Standard Method column in Table E-1 to find Total Required TRV: ft3
Volume (TRV) If CAS Volume (from Step 2) Is greater than TRV then no outdoor openings are needed. If CAS Volume (from Step 2) is less than
TRV then go to STEP 5.
4b. Known Air Infiltration Rate (KAIR) Method (DO NOT COUNT DIRECT VENT APPLIANCES)
Total Btu/hr input of all fan -assisted and power vent appliances Input: 55,000 Btu/hr
Use Fan -Assisted Appliances column in Table E-1 to find RVFA: 4125 ft3
Required Volume Fan Assisted (RVFA)
Total Btu/hr input of all Natural draft appliances Input: Btu/hr
Use Natural draft Appliances column in Table E-1 to find RVNFA: -_____ ft3
Required Volume Natural draft appliances (RVNDA)
Total Required Volume (TRV) = RVFA + RVNDA TRV = 4125 + = 4125 TRV ft3
If CAS Volume from Step 2 /s greater than TRV then no outdoor openings are needed. If CAS Volume from Ste 2 /s less than TRV then go to STEP 5.
Step 5: Calculate the ratio of available interior volume to the total required volume.
Ratio = CAS Volume (from Step 2) divided by TRV (from Step 4a or Step 4b)
Ratio = 1728 / 4125 —.41
Step 6: Calculate Reduction Factor (RF). RF = 1 minus Ratio
RF = 1 - .41 _ .59
Step 7: Calculate single outdoor opening as if all combustion air is from outside. Total Btu/hr input of all Combustion Appliances in the same CAS
Input: 55000 Btu/hr (EXCEPT DIRECT VENT)
Combustion Air Opening Area (CAOA): Total Btu/hr divided by 3000 Btu/hr per in
CAOA = 55000 / 3000 Btu/hr per int = 18.3 int
Step 8: Calculate Minimum CAOA: Minimum CAOA = CAOA multiplied by RF
Minimum CAOA = 18.3 x .59 _ 10.7 in
Step 8: Calculate Combustion Air Opening Diameter (CAOD): CAOD = 1.13 multiplied by the square root of Minimum CAOA
CAOD = 1.13 4 Minimum CAOA = 3.7 in. diameter go up one Inch in size if using flex duct
1 If desired, ACH can be determined using ASHRAE calculation or blower door test. Follow procedures in Section 6304.
The 1994 date refers to dwellings constructed under the 1994 Minnesota Energy Code. The default KAIR used in this section of the table is
0.20 ACH.
This section of the table is to be used for dwellings constructed prior to 1994. The default KAIR used in this section of the table is 0.40 ACH.
IFGC Appendix E, Table E-1
Residential Combustion air (Required Interior Volume Based on Input Rating of Appliance)
Input Rating
(Btu/hr)
Standard Method
Known Air Infiltration Rate (KAIR) Method (cu ft)
Fan Assisted or Power Vent Natural Draft
1994 to present Pre -1994 1994 to present Pre -1994
5,000
250
375
188
525
263
10,000
500
750
375
1,050
525
15,000
750
1,125
563
1,575
788
20,000
1,000
1,500
750
2,100
1,050
25,000
1,250
1,875
938
2,625
1,313
30,000
1,500
2,250
1,125
3,150
1,575
35,000
1,750
2,625
1,313
3,675
1,838
40,000
2,000
3,000
1,500
4,200
2,100
45,000
2,250
3,375
1,688
4,725
2,363
50,000
2,500
3,750
1,675
5,250
2,625
55,000
2,750
4,125
2,063
5,775
2,888
60,000
3,000
4,500
2,250
6,300
3,150
65,000
3,250
4,875
2,438
6,825
3,413
70,000
3,500
5,250
2,625
7,350
3,675
75,000
3,750
5,625
2,813
7,875
3,938
80,000
4,000
6,000
3,000
8,400
4,200
85,000
4,250
6,375
3,188
8,925
4,463
90,000
4,500
6,750
3,375
9,450
4,725
95,000
4,750
7,125
3,563
9,975
4,988
100,000
5,000
7,500
3,750
10,500
5,250
105,000
5,250
7,875
3,938
11,025
5,513
110,000
5,500
8,250
4,125
11,550
5,775
115,000
5,750
8.625
4,313
12,075
6,038
120,000
6,000
9,000
4,500
12,600
6,300
125,000
6,250
9,375
4,688
13,125
6,563
130,000
6,500
9,750
4,875
13,650
6,825
135,000
6,750
10,125
5,063
14,175
7,088
140,000
7,000
10,500
5,250
14,700
7,350
145,000
7,250
10,875
5,438
15,225
7,613
150,000
7,500
11,250
5,625
15,750
7,875
155,000
7,750
11,625
5,813
16,275
8,138
160,000
8,000
12,000
6,000
16,800
8,400
165,000
8,250
12,375
6,188
17,325
8,663
170,000
8,500
12,750
6,375
17,850
8,925
175,000
8,750
13,125
6,563
18,375
9,188
180,000
9,000
13,500
6,750
18,900
9,450
185,000
9,250
13,875
6,938
19,425
9,713
190,000
9,500
14,250
7,125
19,950
9,975
195,000
9,750
14,625
7,313
20,475
10,238
200,000
10,000
15,000
7,500
21,000
10,500
205,000
10,250
15,375
7,688
21,525
10,783
210,000
10,500
15,750
7,875
22,050
11,025
215,000
10,750
16,125
8,063
22,575
11,288
220,000
11,000
16,500
8,250
23,100
11,550
225,000
11,250
16,875
8,438
23,625
1 11,813
230,000
11,500
17,250
8,625
24,150 1
12,075
The 1994 date refers to dwellings constructed under the 1994 Minnesota Energy Code. The default KAIR used in this section of the table is
0.20 ACH.
This section of the table is to be used for dwellings constructed prior to 1994. The default KAIR used in this section of the table is 0.40 ACH.
HVAC Load Calculations
for
SD Custom Homes
4014 Haven Woods Ct
Eagan, MN
Prepared By:
Samantha Lykke
Air Mechanical
16411 Aberdeen St NE
Ham Lake, MN 55304
Thursday, January 26, 2023
Rhvac is an ACCA approved Manual J, D and S computer program.
Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D.
Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc.
Air Mechanical Inc.
Ham Lake, MN 55304 Paae
Pro "ect Re ort
General Proiect Information
Project Title:
Project Date: Thursday, January 26, 2023
Client Name: SD Custom Homes
Client Address: 4014 Haven Woods Ct
Client City: Eagan, MN
Company Name: Air Mechanical
Company Representative: Samantha Lykke
Company Address: 16411 Aberdeen St NE
Company City: Ham Lake, MN 55304
Desi n Data
Reference City: Minneapolis, Minnesota
Building Orientation: Front door faces North
Daily Temperature Range: Medium
Latitude: 44 Degrees
Elevation: 834 ft.
Altitude Factor: 0.970
Outdoor Outdoor Outdoor Indoor Indoor Grains
Dry Bulb Wet Bulb Rel -Hum Rel -Hum Dry Bulh Difference
Winter: -15 -12.38 n/a 30% 72 29.40
Summer: 88 73 50% 50% 74 37
Check Figures
Total Building Supply CFM: 1,268 CFM Per Square ft.: 0.333
Square ft. of Room Area: 3,804 Square ft. Per Ton: 1,341
Volume (ft3): 24,726
Building Loads
Total Heating Required Including Ventilation Air: = 64.412 MBH
Total Sensible Gain:-.-Btuh 83 %
Total Latent Gain: 5,927 Btuh 17 %
Total Cooling Required Including Ventilation Air: Q4,0 _Btuh ons(Based On Sensible + Latent)
Notes
Rhvac is an ACCA approved Manual J, D and S computer program.
Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at
your design conditions.
C:\Users\Siykke\Desktop\4014 Haven Woods Ct.rh9 Thursday, January 26, 2023, 1:01 PM
C:\Users\Slykke\Desktop\4014 Haven Woods Ct.rh9 Thursday, January 26, 2023, 1:01 PM
Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc.
Air Mechanical Inc.
Ham Lake, MN 65304Page
Miscellaneous Re ort
System 1 ;:
Outdoor
Outdoor Outdoor Indoor Indoor Grains
Input Data s i
k D Bulb
Wet Bulb Rel.Hum Rei.Hum Dry Bulb Difference
Winter: -15
-12.38 100% 30% 72 29.40
Summer: 88
73 50% 50% 74 37.40
Duct Sizin inputs
Main Trunk
Calculate: Yes
$ute
Yes
Use Schedule: Yes
Yes
Roughness Factor: 0.00300
0.01000
Pressure Drop: 0.1000 in.wg./100 ft.
0.1000 in.wg./100 ft.
Minimum Velocity: 0 ft./min
0 ft./min
Maximum Velocity: 900 ft./min
750 ft./min
Minimum Height: 0 in.
0 in.
Maximum Height: 0 in.
0 in.
Outside Air Data
Winter
Infiltration Specified: 0.280 AC/hr
Summer
0.150 AC/hr
115CFM
6.2 CFM
Infiltration Actual: 0.223 AC/hr
0.000 AC/hr
Above Grade Volume: X 24,726 Cu.ft.
X 24,726 Cu.ft.
5,520 Cu.ft./hr
0 Cu.ft./hr
X 0.0167
Total Building Infiltration: 92 CFM
X 0.0167
0 CFM
Total Building Ventilation: 70 CFM
70 CFM
—System 1—
Infiltration & Ventilation Sensible Gain Multiplier: 14.94
= (1.10 X 0.970 X 14.00 Summer Temp. Difference)
Infiltration & Ventilation Latent Gain Multiplier: 24.67
= (0.68 X 0.970 X 37.40 Grains Difference)
Infiltration & Ventilation Sensible Loss Multiplier: 92.85
= (1.10 X 0.970 X 87.00 Winter Temp. Difference)
Winter Infiltration Specified: 0.280 AC/hr (115 CFM), Construction:
Average
Summer Infiltration Specified: 0.150 AC/hr (62 CFM), Construction: Average
C:\Users\Slykke\Desktop\4014 Haven Woods Ct.rh9 Thursday, January 26, 2023, 1:01 PM
Rhvac - Residential & Light Commerclal HV14C Loads Elite Software Development, Inca
Air Mechanical Inc.
Ham Lake MN 55304 Page 4
Load Preview Report
Scope
To
/To
Areal
Gai
Gai
Gal
Losj
CFMj
CFMI
CFMj
51Z'
Bulldinq
2.84 1,341 3,804 28,103 5,927 34,030 775
1,268 1,268
System 1
_64,412
2.84 1,341 3,804 28,102 5,927 34,030 64,412 775'
1,268 1,268 12x1
Ventilation
1,046 1,727 2_,773 6,500
Humidification
3,595
Zone 1
3,804 27,057 4,200 31,257 54,318 775,
1,268 _ 1,268 12x1
1 -Lower Level
1,902 9,425 1,600 11,02; 22,601
323;
442
442
_5-i
2 -Main Level
1,902 17,632 2,600 20,232 31,717 453 826
C:\Users\Slykke\Desktop\4014 Haven Woods Ct.rh9 Thursday, January 26, 2023,1:01 PM
C:\Users\Slykke\Desktop\4014 Haven Woods Ct.rh9 Thursday, January 26, 2023,1:01 PM
Rhvac - Residential & Light Commercial HVAC Loads
Elite Software Development, Inc.
Air Mechanical Inc.
Ham Lake, MN 55304
Pane 5
Duct Size Preview
Room or
S
Source
Minimu
Maximu
Rough
Desig
SP
Ducl
Htg
Clg
Act.
Duct
Reg
Duct Name
Veloc
IV -d
Facto
U10
Loss
Velocit
LeDuc
ng
Size
Svstem 1
Supply Runouts
Zone 1
1-Lower Level Built-In
0 750
0.01 0.1
449.8
323011W
442
5-6
2-Main Level Built-In
0 750
0.01 0.1
386.4
453
I 826
8-7
Other Ducts-'In System 1
Supply Main Trunk Built-In
0 900
0.003 0.1
845.1
775,::=-. 26
1,268 12x18
Summary
System 1
Heating Flow: 775
Coolinq Flow: 1268
C:\Users\Slykke\Desktop\4014 Haven Woods Ct.rh9 Thursday, January 26, 2023,1:01 PM
C:\Users\Slykke\Desktop\4014 Haven Woods Ct.rh9 Thursday, January 26, 2023, 1:01 PM
Rhvac - Residential & Light Commercial HVAC Loads
Air Mechanical Inc.
Elite Software Development, Inc.
Ham Lake MN 55304
P
Total Building Summary Loads
Component
Area
Sen
Lat
Sen
Total
Description
Quan
Loss
Gain
Gain
Gain
4a: Glazing-
687.5
19,135
0
12,050
12,050
4agdoor: Glazing-
21
585
0
761
761
11 G: Door -Wood - Panel, U -value 0.54
21
987
0
284
284
11 P: Door -Metal - Polyurethane Core, U -value 0.29
21
530
0
152
152
15BO-10sf-4: Wall -Basement, , R-10 board insulation to
896
4,208
0
0
0
floor, no interior finish, 4' floor depth, U -value 0.054,
above grade U -value 0.083
12F-Obw: Wall -Frame, R-21 insulation in 2 x 6 stud
2161.5
12,223
0
1,348
1,348
cavity, no board insulation, brick finish, wood studs,
U -value 0.065
16B-44: Roof/Ceiling-Under Attic with Insulation on Attic
1902
3,640
0
2,050
2,050
Floor (also use for Knee Walls and Partition
Ceilings), Vented Attic, No Radiant Barrier, Dark
Asphalt Shingles or Dark Metal, Tar and Gravel or
Membrane, R-44 insulation, U -value 0.022
21A-20: Floor -Basement, Concrete slab, any thickness, 2
1902
4,468
0
0
0
or more feet below grade, no insulation below floor,
any floor cover, shortest side of floor slab is 20' wide,
U -value 0.027
Subtotals for structure:
45,776
0
16,645
16,645
People:
4
800
920
1,720
Equipment:
3,400
5,400
8,800
Lighting:
1200
4,092
4,092
Ductwork:
0
0
0
0
Infiltration: Winter CFM: 92, Summer CFM: 0
8,542
0
0
0
Ventilation: Winter CFM: 70, Summer CFM: 70
6,500
1,727
1,046
2,773
Exhaust: Winter CFM: 0, Summer CFM: 0
Humidification (Winter) 9.80 gaVday__
3,595
0
0
0
Total Building Load Totals:
64,412
5,927
28,103
34,030
Check Figures
Total Building Supply CFM: 1,268
CFM Per Square ft.:
0.333
Square ft. of Room Area: 3,804
Square ft. Per Ton:
1,341
Volume (W): 24,726
FB_uilding Loads
Total Heating Required Including Ventilation Air:
64,412 Btuh
64.412 MBH
Total Sensible Gain:
28,103 Btuh
83 %
Total Latent Gain:
5,927 Btuh
17 %
Total Cooling Required Including Ventilation Air:
34,030 Btuh
2.84 Tons
(Based On Sensible + Latent)
Notes
Rhvac is an ACCA approved Manual J, D and S computer program.
Calculations are performed per ACCA Manual J 8th Edition, Version 2, and
ACCA Manual D.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads according
to the manufacturer's performance data at
your design conditions.
C:\Users\Slykke\Desktop\4014 Haven Woods Ct.rh9 Thursday, January 26, 2023, 1:01 PM
C:\Users\Slykke\Desktop\4014 Haven Woods Ct.rh9 Thursday, January 26, 2023, 1:01 PM
Rhvac - Residential & Light Commercial HVAC Loads
Air Mechanical Inc.
Elite Software Development, Inc.
Ham Lake,
7
Detailed Room Loads - Room 1 - Lower Level Avera a Load Procedure
General
Calculation Mode: Htg. & clg.
Occurrences:
1
Room Length:
n/a
System Number:
1
Room Width:
n/a
Zone Number:
1
Area:
1,902.0 sq.ft.
Supply Air:
442 CFM
Ceiling Height:
8.0 ft.
Supply Air Changes:
1.7 AC/hr
Volume:
15,216 cu.ft.
Req. Vent. Cig:
0 CFM
Number of Registers:
5
Actual Winter Vent.:
29 CFM
Runout Air:
88 CFM
Percent of Supply.:
7 %
Runout Duct Size:
6 in.
Actual Summer Vent.:
24 CFM
Runout Air Velocity:
450 ft./min.
Percent of Supply:
6 %
Runout Air Velocity:
450 ft./min.
Actual Winter Infil.:
28 CFM
Actual Loss:
0.127 in.wg./100
ft.
Actual Summer Infil.:
0 CFM
Item
Area
-U-
Htg Sen
Cig
Lat
Sen
Description
janft
Value
HTM Loss
HTM
Gain
Gain
N -Wall-I5BO-10sf-4 66 X 4
264
0.054
4.7 1,240
0.0
0
0
- Abv. grade U -value 0.083
E -Wall-I5BO-10sf-4 46 X 4
184
0.054
4.7 864
0.0
0
0
- Abv. grade U -value 0.083
S -Wall-15BO-10sf-4 66 X 4
264
0.054
4.7 1,240
0.0
0
0
- Abv. grade U -value 0.083
W -Wall-15BO-10sf-4 46 X 4
184
0.054
4.7 864
0.0
0
0
- Abv. grade U -value 0.083
N -Wall-12F-Obw 66 X 4
54
0.065
5.7 305
0.6
0
34
E -Wall-12F-0bw 46 X 4
145
0.065
5.7 820
0.6
0
90
S -Wall-12F-0bw 66 X 4
252
0.065
5.7 1,425
0.6
0
157
W -Wall-12F-0bw 46 X 4
164
0.065
5.7 927
0.6
0
102
N -GIs -4a shgc-0.34100%S (9)
162
0.320
27.8 4,509
10.9
0
1,773
N -GIs -4a shgc-0.34 100%S (2)
48
0.320
27.8 1,336
10.9
0
524
E -GIs -4a shgc-0.34 0%S
10
0.320
27.8 278
36.3
0
363
E -GIs -4a shgc-0.34 0%S
5
0.320
27.8 139
36.2
0
181
E -GIs -4a shgc-0.34 0%S (2)
24
0.320
27.8 668
36.3
0
870
S -GIs -4a shgc-0.34 0%S (2)
12
0.320
27.8 334
20.0
0
240
W -GIs -4a shgc-0.34 0%S (2)
20
0.320
27.8 556
36.3
0
726
Floor -21A-20 1 X 1902
1902
0.027
2.3 4,468
0.0
0
0
Subtotals for Structure:
19,973
0
5,060
Infil.: Win.: 28.3, Sum.: 0.0
896
2.933 2,628
0.000
0
0
People: 200 [at/per, 230 sen/per:
2
400
460
Equipment:
1,200
2,200
Lighting:
500
1705
Room Totals:
_
22,601
1,600
9,425
C:\Users\Slykke\Desktop\4014 Haven Woods Ct.rh9 Thursday, January 26, 2023, 1:01 PM
C:\Users\Slykke\Desktop\4014 Haven Woods Ct.rh9 Thursday, January 26, 2023, 1:01 PM
Rhvac - Residential & Light Commercial HVAC Loads
Air Mechanical Inc.
Elko Software Development, Inc.
Ham Lake, 55304
Pane 8
Detailed Room Loads - Room 2 - Main Level (Average Load Procedure
General
Calculation Mode: Htg. & clg.
Occurrences:
1
Room Length:
n/a
System Number:
1
Room Width:
n/a
Zone Number:
1
Area:
1,902.0 sq.ft.
Supply Air:
826 CFM
Ceiling Height:
9.0 ft.
Supply Air Changes:
2.9 AC/hr
Volume:
17,118 cu.ft.
Req. Vent. Cig:
0 CFM
Number of Registers:
8
Actual Winter Vent.:
41 CFM
Runout Air:
103 CFM
Percent of Supply.:
5 %
Runout Duct Size:
7 in.
Actual Summer Vent.:
46 CFM
Runout Air Velocity:
386 ft./min.
Percent of Supply:
6 %
Runout Air Velocity:
386 ft./min.
Actual Winter Infil.:
64 CFM
Actual Loss:
0.076 in.wg./100
ft.
Actual Summer Infil.:
0 CFM
Item
Area
-U-
Htg Sen
Clg
Lat
Sen
Description
Quantily
Value
HTM Loss
HTM
Gain
Gain
N -Wall-12F-Obw 66 X 9
354
0.065
5.7 2,002
0.6
0
221
E -Wall-12F-0bw 46 X 9
360.5
0.065
5.7 2,039
0.6
0
225
S -Wall-12F-0bw 66 X 9
473
0.065
5.7 2,675
0.6
0
295
W -Wall-12F-0bw 46 X 9
359
0.065
5.7 2,030
0.6
0
224
S -Door -11 G 3 X 7
21
0.540
47.0 987
13.5
0
284
S -Door -11 P 3 X 7
21
0.290
25.2 530
7.3
0
152
N -GIs -4a shgc-0.34100%S (9)
162
0.320
27.8 4,509
10.9
0
1,773
N -GIs -4a shgc-0.34100%S (2)
48
0.320
27.8 1,336
10.9
0
524
N -GIs -4a shgc-0.34 1 00%S
30
0.320
27.8 835
10.9
0
328
E -GIs -4a shgc-0.34 0%S
12.5
0.320
27.8 348
36.2
0
453
E -GIs -4a shgc-0.34 0%S (2)
20
0.320
27.8 556
36.3
0
726
S -GIs -4a shgc-0.34 0%S (2)
25
0.320
27.8 696
19.9
0
498
S -GIs -4a shgc-0.34 0%S (3)
54
0.320
27.8 1,503
19.9
0
1,077
W -GIs -4a shgc-0.34 0%S (2)
25
0.320
27.8 696
36.2
0
906
W -GIs -4a shgc-0.34 0%S (2)
30
0.320
27.8 836
36.3
0
1,088
E -GIs-4agdoor shgc-0.34 0%S
21
0.320
27.8 585
36.2
0
761
UP-Ceil-16B-44 1902 X 1
1902
0.022
1.9 3,640
1.1
0
2,050
Subtotals for Structure:
25,803
0
11,585
Infil.: Win.: 63.7, Sum.: 0.0
2,016
2.934 5,914
0.000
0
0
People: 200 lat/per, 230 sen/per:
2
400
460
Equipment:
2,200
3,200
Lighting: _._._
700
__.
2,387
Room Totals:
31,717
2,600
17,632
C:\Users\Slykke\Desktop\4014 Haven Woods Ct.rh9 Thursday, January 26, 2023, 1:01 PM
C:\Users\Slykke\Desktop\4014 Haven Woods Ct.rh9 Thursday, January 26, 2023,1:01 PM
Rhvac - Residential $ Light Commercial HVAC Loads
Air Mechanical Inc.
Elite Software
Development, Inc.
Ham Lake. MN 55304
Page 9
S stem 1 Room Load Summaty
Room
Area
Htg Min Run
Sens Htg Duct
Run
Duct
Clg
Sens
Clg
Lat
Min
Clg
Act
Sys
No Name
SF
Btuh CFM Size
Vol
Btuh
Btuh
CFM
CFM
—Zone 1-
1 Lower Level
1,902
22,601 323 5-6
450
9,425
1,600
442
442
2 Main Level
1,902
31,717 453 8-7
386
17,632
2,600
826
826
Ventilation
6,500
1,046
1,727
Humidification
3.595
System 1 total
3,804
64,412 775
5,927
1,268
1,268
System 1 Main Trunk Size:
12x18 in.
__28,103
Velocity:
845 ft./min
Loss per 100 ft.:
0.097 in.wg
Fdoollng System Summa
Cooling
Sensible/Latent
Sensible
Latent
Total
Tons
S lit
Btuh
Btuh
Btuh
Net Required:
2.84
83%/17%
28,103
5,927
34,030
E ui ment Data
Type:
Heating System
Natural Gas Furnace
Cooling Salem
Standard Air Conditioner
Model:
Indoor Model:
Brand:
Efficiency:
0 AFUE
0 SEER
Sound:
0
0
Capacity:
0 Btuh
0 Btuh
Sensible Capacity:
n/a
0 Btuh
Latent Capacity:
n/a
0 Btuh
C:\Users\Slykke\Desktop\4014 Haven Woods Ct.rh9 Thursday, January 26, 2023,1:01 PM
EAGAN
City Inspection Dept. Copy
City Forester Copy
Applicant/Builder Copy
INDIVIDUAL RESIDENTIAL LOT
TREE PRESERVATION PLAN SUMMARY
CITY OF EAGAN FORESTRY DIVISION
651-675-5300
(BUILDER, PLEASE READ ATTACHMENTS)
Development Haven Woods
Lot Number 5 Block Number 1
Address 4014 Haven Woods Ct
Builder SD Custom Homes Inc
Phone Number: (651) 9943997
Contact: Sean Doyle
Tree Protection Requirements:
X Tree -Protection Fencing must be Installed and inspected
Oak Tree Pruning (immediately seal wounds during April 1 to July 31)
Therapeutic Pruning Required
Retaining Wall To Be Installed
Other:
(Replacement Trees:
Not Required
X As Follows: Per approved Tree Mitigation Plan, the following
tree(s) are to be planted following construction: One (1) Category B
;Red Maple tree (>= 2.5" caliper deciduous trees) is to be installed In
the front yard. Final Location TBD
Attachments: EAGAN FORESTRY DIVISION
X Yes (Refer to attached d
No
BY — _
Additional Notes:
.�.,
(Call 651-675-5300_ to s ,h�aT��^s�s+i�nn. 7�.3liD2�
TREE PRESERVATION PLAN - H3vcn Woody Lot 5 Bleck Ldocx
4014 Havenwoods Ct
EAGAN
Lakes
Storm Basin
Wetlands
Sections Numbers
Street Names
Aerial Street Names
1 in=94ft
ti
City of Eag n GIS
Fegruary 2, 20.
Map Powered by DataLink
TREE PRESERVATION PLAN REVIEW —INDIVIDUAL LOT ,r,
EAGAN
Date Building Permit Application Received 1/31/23
Development Haven Woods Lot 5 Block 1
Site Address 4014 Haven Woods Ct
Builder SD Custom Homes Contact Sean Doyle
Telephone(651) 994-3997 E-mail sean(a)sd-custom homes. com
Property/Lot Owner Name=
Telephone - E-mail -
Office Plan Review — Date 2/1/23 Notes Per approved tree mitigation plan,
One (1) Category B trees (>= 2.5" caliper deciduous trees, or >= 6' conifer trees) trees are to be installed on
site after construction: One (1) Sugar Maple tree to be installed in front yard. Certificate of survey shows
a potential conflict between preserved trees and the location of a swimming pool thus, tree protection fencing
shall be required to be installed along the east property line. Damage to exiting trees may result in additional mitigation.
Tree Preservation Data
Total Significant Woodland Area
Total Significant Trees
Woodland To Be Removed
Trees To Be Removed
Allowable Woodland Removal (20%)
Allowable Tree Removal (20%)
Required Mitigation YES (or) NO
Original Plan
ft
sq. ft
ft
Revised Plan
Calculated Mitigation Amounts
Original Plan - Category A Category B Category C
Revised Plan - Category A Category B Category C
ft
sq. ft
Site Inspection — Date 2/2/23 Notes No silt fence or tree protection fence is installed.
ft
Home location not yet staked. Previously planted mitigation and preserved trees exist along east property
boundary. otherwise lot is clear.
G:\Forestry\TreePreservation\Tree Preservation Plan Review - Individual Lot.docx
Original Tree Preservation Plan Approved — Date 8-6-2018 By GH
Forwarded to Inspections— Date 2/2/2023
By AS
Discussion/Meetings with Builder/Owner - Notes
Revised Tree Preservation Plan Approved — Date
Forwarded to Inspections — Date By
Additional Field Inspections
Date Notes
Date Notes
Date Notes
Date Notes
G:\Forestry\TreePreservation\Tree Preservation Plan Review - Individual Lot.docx
Was the approved Tree Preservation Plan followed? YES (or) NO
If no, was additional mitigation required? YES (or) NO (If yes, describe additional mitigation below)
Final Site Inspection — Date Notes
Additional Notes and/or aerial photo image
(insert aerial image or draw map of site)
G:\Forestry\TreePreservation\Tree Preservation Plan Review - Individual Lot.docx
Gam• 9103 ` CERTIFICATE OF SURVEY FOR:
r SD CUSTOM HOMES
X258 �
LANDSCAPE LEGEND:
LEGEND:
X 934.0
EXISTING ELEVATION
PROPOSED DECIDUOUS
F934 --Q
PROPOSED ELEVATION
OVERSTORY TREE
IMPERVIOUS AREA = 5,954 SO. FT (35.9%)
BUILDING FOOTPRINT AREA = 2,728 SO. FT.
NOTES:
DIRECTION OF DRAINAGE
PROPOSED
`
\y / bo
CONIFEROUS TREE
0
IRON MONUMENT SET
1. SURVEY PREPARED FROM ALUANT
ENGINEERING, INC. GRADING PLAN DATED
PROPOSED
iCS
CURB STOP
ORNAMENTAL TREE
EOF
EMERGENCY OVERFLOW
LFE
LOWEST POSSIBLE FLOOR
��
• 1 S)PROPOSED
2. BEARINGS ARE ASSUMED PER PLAT
TC
TOP OF CURB
^ ADDRESS: p TELEPHONE BOX
PQ'yA rw . EAGAN,4014 HAVENN WOO55123 SCT. ELECTRIC BOX
XPi / V �N 2 • / 0 EAGAN, MN 55123
~.,,a` /.., ` i/ / j • o (P) ELEVATION PER PLAN
e 4D ♦ / LEGAL DESCRIPTION: PROPOSED CONTOURS
LOT 5, BLOCK 1, HAVEN WOODS
„p ,��` `�. ; �O .� ♦ / DAKOTA COUNTY,MNNESOTA _.-_... _.._.. BUILDING PAD
\\ `J C3, `' ti / • / I I WETLAND BUFFER MONUMENT
CUSTOM ONE HOMES PLAN:
Q Z • / PUN: • 5
L 71
PFr. LOOKOUT WAII(oUT- EXISTING TREES
t° / ♦ �
PLAN
DATE: 1/1123
\ <Da ) # / - —�—� SILT FENCE
LOT AREA:
LOT AREA = 15,132 SO. FT. OR 0.370 ACRES
IMPERVIOUS AREA = 5,954 SO. FT (35.9%)
BUILDING FOOTPRINT AREA = 2,728 SO. FT.
NOTES:
POOL AREA = 800 SO. FT.
POOL DECK AREA 1,548 SO. FT.
`
\y / bo
/
=
♦ / �!�" 0�
1. SURVEY PREPARED FROM ALUANT
ENGINEERING, INC. GRADING PLAN DATED
ELEVATIONS:
OCTOBER 22, 2019.
Q
��
• 1 S)PROPOSED
2. BEARINGS ARE ASSUMED PER PLAT
\
/
nl ( �\ � ��
`�.,
J~
r / y OJ
Q TOP OF FOUNDATION = gOp.,
00 % GARAGE FLOOR =902.2
3. BUILDING DIMENSIONS SHOWN ARE TO
�\ �`
�,,�
• c`1' A/�
/ BASEMENT FLOOR = 094.0
REAR -
OUTSIDE FRAMING OF FIRST FLOOR PLAN.
ALL DIMENSIONS AND LOCATIONS ARE TO
9y
/"�
• / gP Y
egg a
/
BE VERIFIED IN THE FIELD WITH THE
ARCHITECTURAL PLANS.
BENCH MARK:
\ \
• /
TOP NUT OF FIRE HYDRANT AT THE CORNER
OF LOTS 5 AND e,BLOCK 1, HAVEN WOODS
ELEVATION = 903.12 (NGVD29)
Tree protection fencing
'�
•
required to be installed and
inspected
Call 651-675-5300 to RFnffD rO&3Sftb ro S¢P B0.ENTRE—SI
sDCus'iPMrpaES xnry rrw ney. qan. °r ren°n was peRv°e pma °.
�yc
/ ♦
•
schedule an inspection °
umereirecr wpervi o°aM inai auNUcenrd Lam
DANIEL°EKREMawa °l Nm ra
OPE
0 10 20 40
Aniad E1911 --g, mc.
733 Merquene Ave. Ste 700
HAVEN WOODS Wn—pdiS, MN 55402
N
812.758.3080 AWN
16
LOT 5, BLOCK 1 812,7W3099—
6.3099 —
IN
SCALE IN FEET
EAGAN, MINNESOTA wwwallim,nc—
Required Mitigation Planting
4014 Haven Woods Ct
-(1) Autumn Blaze Maple—Final Location TBD
�• LE
o �
qv
� P
�V
O` wo
r
KEY COMMON NAME BOTANICAL NAME SIZE H X W REMARKS
7 \
O'
/
e
OQ J �G
d
6
CH
COMMON HACKBERRY Celtis occidentailis
2.5" CAL. B&B
50' X 50'
STRWCHT TRUNK. No V -CROTCH
7
RM
AUTUMN"B�1 MAPLE Acer` x freernanii 'Jeff;;" -red
.5 'CAL. B&B
50' X
s�GHT VvW, No V -CROTCH
7
GL
GREENSPIRE LINDEN Tilia Cordata 'Greenspire'
2.5" CAL. B&B
50' X 20
STRNCHT T"K, NO V -CROTCH
31
BS
CONIFEROUS TREES
BLACKHILLS SPRUCE Picea glauca densata
6' HT B&B
30' X 20'
nu nxn.
11
NP
NORWAY PINE Pinus resinosa
�V
O` wo
r
KEY COMMON NAME BOTANICAL NAME SIZE H X W REMARKS
/
931
O'
DECIDUOUS TREES
e
OQ J �G
6
CH
COMMON HACKBERRY Celtis occidentailis
2.5" CAL. B&B
50' X 50'
00'.0' OV
LANDSCAPE SCHEDULE
MATURE
KEY COMMON NAME BOTANICAL NAME SIZE H X W REMARKS
DECIDUOUS TREES
6
CH
COMMON HACKBERRY Celtis occidentailis
2.5" CAL. B&B
50' X 50'
STRWCHT TRUNK. No V -CROTCH
7
RM
AUTUMN"B�1 MAPLE Acer` x freernanii 'Jeff;;" -red
.5 'CAL. B&B
50' X
s�GHT VvW, No V -CROTCH
7
GL
GREENSPIRE LINDEN Tilia Cordata 'Greenspire'
2.5" CAL. B&B
50' X 20
STRNCHT T"K, NO V -CROTCH
31
BS
CONIFEROUS TREES
BLACKHILLS SPRUCE Picea glauca densata
6' HT B&B
30' X 20'
nu nxn.
11
NP
NORWAY PINE Pinus resinosa
6' HT B&B
50' X 30'
FuLL rora
8
BF
BALSAM FIR Abies balsamea
6' HT B&B
40' X 30'
nu roRt.
NOTE:
DECIDUOUS TREE: DIAMETER OF THE TREE MEASURED ONE FOOT ABOVE THE GROUND LEVEL IN CALIPER INCH.
CONIFEROUS TREE—IS MEASURED IN HEIGHT.
3:1 MAX. SLOPES OR
RETAINING WALL REQUIRED
��ww i 111,
INSTALL PERIMETER
CONTROL Q
REVIEWED
EAGAN
dwestermayer
02/07/2023
ENGINEERING
o\ O
rn
CERTIFICATE OF SURVEY FOR:
900.3
SD CUSTOM HOMES
42.66
10 TW -902-3
2114 GFE-901.8 /
.9" _ BFE-983.8
l AOR �Y REAR -8929
/ \NqG f y36 \
nr &Irl S2.// r0
/0' �ICOi � \4ry \gSeM f
—SAN (P)-, / X, /
O y 889.3 ?o
'Apoap/ 100
\\ /
a
CS (P)
-897.9
/o
/Oo ?so /lb
?o
??o/P0
/
lb
A,
f;fE--9023 \ Z� j �O \O� ?P 'V V
SFE -984.1
REAR -893.4
C7�
/'3v Pool Requires
\
Separate Permit.
a,
LANDSCAPE LEGEND:
° PROPOSED DECIDUOUS
OVERSTORY TREE
PROPOSED
CONIFEROUS TREE
PROPOSED
ORNAMENTAL TREE
ADDRESS:
a �\ 4014 HAVEN WOODS CT.
EAGAN, MN 55123
LEGAL DESCRIPTION:
LOT 5, BLOCK 1, HAVEN WOODS
DAKOTA COUNTY, MINNESOTA
CUSTOM ONE HOMES PLAN:
PLAN: # 5
-9 FT. LOOKOUT WALKOUT -
PLAN DATE: 1/11/23
LOT AREA:
LOT AREA = 16,132 SQ. FT. OR 0.370 ACRES
IMPERVIOUS AREA = 5,964 SQ. FT (36.9%)
LEGEND:
X 934.0 EXISTING ELEVATION
934.0 PROPOSED ELEVATION
DIRECTION OF DRAINAGE
0
IRON MONUMENT SET
CS
CURB STOP
EOF
EMERGENCY OVERFLOW
LFE
LOWEST POSSIBLE FLOOR
TC
TOP OF CURB
�T
TELEPHONE BOX
t]E
ELECTRIC BOX
(P)
ELEVATION PER PLAN
GARAGE FLOOR = 902.2
PROPOSED CONTOURS
BUILDING PAD
F-_1
I I WETLAND BUFFER MONUMENT
L—J
EXISTING TREES
0—c�- SILT FENCE
BUILDING FOOTPRINT AREA = 2,728 SO. FT.
NOTES:
POOL AREA = 800 SQ. FT.
POOL DECK AREA = 1,546 SQ. FT.
1. SURVEY PREPARED FROM ALLIANT
ENGINEERING, INC. GRADING PLAN DATED
OCTOBER 22, 2019.
PROPOSED ELEVATIONS:
2. BEARINGS ARE ASSUMED PER PLAT
TOP OF FOUNDATION = 902.7
GARAGE FLOOR = 902.2
3. BUILDING DIMENSIONS SHOWN ARE TO
BASEMENT FLOOR = 894.0
OUTSIDE FRAMING OF FIRST FLOOR PLAN.
REAR = 896.6
ALL DIMENSIONS AND LOCATIONS ARE TO
BE VERIFIED IN THE FIELD WITH THE
ARCHITECTURAL PLANS.
BENCH MARK:
TOP NUT OF FIRE HYDRANT AT THE CORNER
OF LOTS 5 AND 6, BLOCK 1, HAVEN WOODS
ELEVATION = 903.12 (NGVD29)
\ /° REVISED: 1/18/23 FLIP HOUSE PER CLIENT REQUEST.
\ SD -CUSTOM HOMES Date Staked:
X/XX/XX °
� 5
Affiant Job# Checked By: F
0 10 20 40
'r N
SCALE IN FEET