Loading...
EA181461 - Building - Deck - Issued Date 03/03/2023PERMIT City of Eagan Permit Type: Building 3830 Pilot Knob Rd Eagan, MN 55122 ,;�;; %;,�l, �""' "'"� EAGAN Permit Number: EA181461 (651) 675-5675 www.cityofeagan.com * E R 1 8 1 4 6 1 Date Issued: 3/3/2023 Site Address: 628 Erie Ct Lot: 131 Block: 2 Addition: Lakeside Estates PID:10-44300-02-131 Use: * 10-44300-0Z— 13 1 Description: Sub Type: Deck Construction Type: V -B Work Type: New Description: Census Code: 434 - Residential Additions, Alterations Occupancy: IRC -1 Zoning: R-1 Square Feet: 0 Comments: Fee Summary: (BL) Plan Review $140.35 0801.4222 Valuation: 9,200.00 BL - Base Fee $215.90 0801.4085 Surcharge - Based on Valuation $5.00 9001.2195 Total: $361.25 Contractor: - Applicant - Owner: Broten Design and Build Daniel Childs 704 Bush St 628 Erie Ct Red Wing MN 55044 Eagan MN 55123 (651) 428-2822 This permit shall be null and void if work does not start within 180 days of issuance, or if work is suspended for 180 days or more after started. I hereby acknowledge that I have read this application and state that the information is correct and agree to comply with all applicable State of Minnesota Statutes and City of Eagan Ordinances. Applicant/Permitee: Signature /� �.. �i�•w►�.-tom sued B : Signature a � EAG 0 i VA %1 I / . - I.. I Vv, AY ECEIV E z I `3 3830 PILOT KNOB ROAD I EAGAN, MN 55122-1810 (651) 675-5675 1 FAX: (651) 675-5694 buildinoinspections(a.citvofeagan.com 3 ------------- For Office Use I Building Permit #: I , I , S&W Permit #: I IPermit Fee: � 24 I , I , Date Received: I , I , Date Issued: I ---------------------J RESIDENTIAL BUILDING PERMIT APPLICATION Date: -vL L) Site Address: (I (, (J /`-,C �l Unit #: Applicant is: ❑ Owner Contractor Name:D/ R Ai C H II L -h S Address: bZ � 2(r � / City: vel k_rV It- ( Homeowner State: I' i'JV Zip: Phone: I mail: Type of Description of work: Orel ) f) P_' 1i LA V9S1 Jf/ Work Construction Cost: U t?S+q leo Type of building: 'Single Family ElTownhome, of units ❑ Twin Home Company: ROX=rII D651G7�J �_13ylLb Contact: Building Address: —7h Li is U 5 H .--, ! City: J�E b U AJC-, Contractor State: OWZip:, Email: ill S �1�1 f2r' e Y/f Nci'1,(00 State: LP�hone: License M I Ex iration Date: Sewer & Company: Contact: Water Contractor Address: City: Required for State: Zip: Phone: Email: new construction License #: Expiration Date: ❑ I understand that Plumbing, Mechanical, and Fire Suppression work require separate applications. NOTE: Plans and supporting documents that you submit are considered to be public information. Portions of the information may be classified as non-public if you provide specific reasons that would permit the City to conclude that they are trade secrets. CALL BEFORE YOU DIG. Contact Gopher State One Call at (651) 454-0002 or www.-gopherstateonecall.org for protection against underground utility damage. Contact Gopher State One Call 48 hours before you intend to dig to receive locates of underground utilities. I hereby acknowledge that this information is complete and accurate; that the work will be in conformance with the ordinances and codes of the City Eagan; that I understand this is not a permit, but only an accordance with the approved plan in the case of work whic x Zi�� RbiC� Applicant's Printed Name application for a permit, and work is not to start without a permit; that the work will be h requires a review and approval of plans. X� " � A licant's Signature Required Information for Deck Permits ��/ ❑ jX Dimensions of deck: I " j ' , ❑ Size of posts: (X6 5Yn -b--1- ❑ Footing diameter: �' ?I if LI Z �J *If sizes vary, leave blank and indicate individual siies on plans. ❑ Size of beam(s): D P *Example: 2 - 2" x 12" CL CL R m �o m 0 IL` ❑ Cantilever on beam(s): ❑ Size of joists: Z),10 ❑ Species of lumber for framing: /- ❑ Dimensions of floorboards: Ll k ❑ Pattern of floorboards: `i.e: perpendicular (90 degrees) to joists, 30/45/or 60 degrees to Site Address: 6Z�1 C r ❑ Height of deck from ground:�� ` ❑ Spacing of posts: ❑ Footing depth: *42" minimum for traditional concrete footing. Specify if using engineered footings (i.e., Diamond Pier) and provide installation instructions. ❑ Drop or flush beam(s): F vv�s ❑ Spacing of joists: ❑ Floorboard type: tr ❑ Stair width: r✓� ❑ Stair stringer spacing ❑ Stair length: ❑ Will the deck be built around a cantilevered area? (i.e., a bay with a patio door) ❑ What type of floor framing will the ledger be attached to? (i.e., I -joist, floor truss, 2" x 10", etc.) Distance to property lines: ❑ Side 1: ❑ Side 2: Type of hardware to be used: Ledger board: ❑ Ledger board connection: ❑ Lateral load connection: Beam to posts: ❑ Post cap (manufacturer/model) ❑ Through bolts (size) ❑ Other approved type Joist to beam: la'Joist hanger ❑ Other ❑ Any other hardware used: �l 2 1 ❑ Rear: 2C ` ❑ Other: qf 1. riJV WL; 6JMP5(JA3 1p-rc-M 76765 3 '©Lis Pt;Q PUs7— U(ULI C.4ke l l Es Z,PEZ LC Yes No 2X I Final Checklist for Permit Submittal Two (2) copies of plans that include: ❑ Cross section view ❑ Plan view ❑ Stair framing view ❑ Applicable supplemental information Site plan, drawn to scale on survey or plat map, including: ❑ Deck dimensions ❑ Distance to property lines SUB TYPES _ Single Family _ 01 of _ Plex Deck WORK TYPES _ New _ Addition Alteration Replace FOR OFFICE USE ONLY Site Address: �:1,�1RIt Permit #: ��`�"� _ _ Fireplace _ Foundation Garage Repair _ Fire Repair Water Damage Egress Window DESCRIPTION Calculated Valuation $ 9,200 Plan Review 025% E Census Code # of Units # of Buildings Type of Construction VB Lower Level _ Porch Pool _ Siding _ Reroof _ Windows Solar Retaining Wall _ Move Building _ Demolish Building" 'Demolition of entire building – give PCA handout to applicant Occupancy IRC 1 MCES System 00% Code Edition 2020 MNRC SAC Units Zoning R-1 City Water Stories Booster Pump Square Feet PRV Fire Suppression Required Separate Stormwater Management Permit Required REQUIRED INSPECTIONS Footings: New Addition ✓ Deck Foundation: Before Backfill Poured Wall Framing: 1 Hour ✓Residential Alteration Braced Wall Framing/Blocking Braced Wall Sheathing (prior to house wrap) Interior Braced Wall Panel(s) Firewalls REVIEWED FOR Insulation CODE COMPLIANCE Fireplace: _Rough In _Air Tes HVAC: Rough In Final _ Radon Control EAGAN Derek Qualle 03/01/2023 3:26:09 PM Reviewed By: FEES Calculated Valuation $ 9,200 Base Fee Plan Review State Surcharge Met Council SAC City SAC Treatment Plant Water Supply & Storage S&W Permit & Surcharge Meter Radio Read Other: $ 215.90 $140.34 $5.00 TOTAL $ 361.24 Siding: _Stucco Lath _Stone Lath _Brick Roof: Ice & Water Final Erosion Control Pool: _Footings —Air/Gas Tests _Final Retaining Wall: _Footings _Backfill _Final Fire Suppression: _Rough In _Final Windows Other: ✓ Final/No C.O. Required Final/C.O. Required Building Inspector New 30' x14' deck, with upper landing and stairs, being built behind garage Deck 30'x 14'= 420 sf Landing 4'x 4' = 16 sf Stairs 3' x 8 = 24 sf Total sf 460 x $20 = $9,200 Required Information for Deck Permits Site Address: 6T, ( f< e (.. ❑ Dimensions of deck: I ❑ Height of deck from ground: % El Size of posts: ❑ E]Spacing of posts: ❑ Footing diameter: , .;t) tri 'Z ❑ Footing depth: ❑ *If sizes vary, leave blank and indicate individual si es on plans. _ Size of beam(s): �, L (� S f ❑ *42" minimum for traditional concrete footing. Specify if using engineered footings (i.e., Diamond Pier) and provide installation i'uttructippons. Drop or flush beam(s): P' 05(-A C !7 �� *Example: 2 — 2" x 12" ❑ Cantilever on beam(s): ❑ Size of joists: k ❑ Species of lumber for framing: u 1* ❑ Dimensions of floorboards: n x h ❑ Pattern of floorboards: pr�—p / (� �; j �� *i.e: perpendicular (90 degrees) to joists, 30/45/or 60 degrees to joists ❑ Stair width: _ LrI1 ❑ Stair length: ❑ Spacing of joists: I b li ) C . Harvest Collection _ ❑ Floorboard type: t a /See attachment for ElStair stringer spacing: ,,,e options ❑ Will the deck be built around a cantilevered area? (i.e., a bay with a patio door) ❑ What type of floor framing will the ledger be attached to? (i.e., I -joist, floor truss, 2"x 10", etc.) Distance to property lines: ❑ Side 1: ❑ Side 2: Type of hardware to be used: i I ❑ Rear: ❑ Other: Yes No See Attachment for _ ledger fastener spacing A MP5(3^� I P r C -Q ,�L (l�S i'�l See attached Code section for requirements R507.5.1 (1&2) Final Checklist for Permit Submittal Two (2) copies of plans that include: REVIEWED FOR Ledger board: CODE COMPLIANCE ❑ Ledger board connection: >. ❑ Lateral load connection: c. �v ❑ Applicable supplemental information Beam to posts: ❑ Post cap (manufacturer/model) ❑ Through bolts (size) m ❑ Other approved type O a Joist to beam: AD --'Joist hanger ❑ Other ❑ Any other hardware used: i I ❑ Rear: ❑ Other: Yes No See Attachment for _ ledger fastener spacing A MP5(3^� I P r C -Q ,�L (l�S i'�l See attached Code section for requirements R507.5.1 (1&2) Final Checklist for Permit Submittal Two (2) copies of plans that include: REVIEWED FOR CODE COMPLIANCE ❑ cross section view ❑ Plan view _ ❑ Stair framing view EAGAN Derek Dualle ❑ Applicable supplemental information 03/02120232:27:49 PM BUILDING INSPECTIONS Site plan, drawn to scale on survey or plat map, including: ❑ Deck dimensions ❑ Distance to property lines 10 Survey plat of Lot 12 and Lot 13, and sub—division of Lot 13, all in Block 2 of the plat of IAK- IDE ESTATES as of record and of file in Register of Deeds# Dakota Co., Minn. Surveyed this 3rd day of April 1976. C REGISTRATION NO. 628 Erie ct EA 181461 LEO B. SHAW, LAND SURVEYORS REGISTERED UNDER LAWS OF STATE OF MINK• P.O. BOX 276 HWY NO. 13 and NICOLLET AVE. REVIEWED FOR SAVAGE, MINNESOTA 55378 CODE COMPLIANCE 1 —0, "' .1, SURVEYORS CERTIFICATE EAGAN Derek Glualle (� 03/02/2023 1:23:06 PM BUILDING INSPECTIONS �,1 Per contractor, septic was removed years ago and is NOT ' present on Dakota County GIS - OK. Ensure footings are on good soil for bearing. 1-7 ,.-C ,V -r 0 6 ti _ • tom. � `�- -�- o \ f r A d r .� r o5 � O f\ _ 9S o 6 cAl I I 10 Survey plat of Lot 12 and Lot 13, and sub—division of Lot 13, all in Block 2 of the plat of IAK- IDE ESTATES as of record and of file in Register of Deeds# Dakota Co., Minn. Surveyed this 3rd day of April 1976. C REGISTRATION NO.