Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
EA181856 - Sign - Building - Issued Date 03/24/2023
PERMIT City of Eagan m Permit"': Sign 3830 Pilot Knob Rd ��ax�' %�.A , Permit Number: EA181856 Eagan,MN 55122 EAGAN (651)675-5675 11111111111111111111111111111111111111111111111 www.cityofeagan.com * E R 1 8 1 8 5 6 * Date Issued: 3/24/2023 Site Address: 3965 Eagan Outlets Pkwy Lot: 1 Block: 1 Addition: Paragon Addition PID:10-56220-01-010 Use: Zumiez * 1 0 — 5 6 2 2 0 — 0 1 — 0 1 0 Description: Sub Type: Building Work Type: New Feet Inches Description: Board Length: 2 0 Height: 2 0 Sign Message: Width: 0 1 ZUMIEZ SgFt: 4.00 Location: Front Elevation: 0 Electric: Y Double: N Comments: Please call(651)675-5687 for a final inspection. New sign faces require separate permits. Fee Summary: Base Fee-$2.50 sq. ft. $60.00 0720.4089 Total: $60.00 Contractor: _ Applicant _ Owner: Sign Minds Inc. Paragon Outlets Eagan LLC 1400 Quincy St NE %Simon Property Group Minneapolis MN 55413 PO Box 6120 (651)450-7273 Indianapolis IN 46206 This permit shall be null and void if work does not start within 180 days of issuance,or if work is suspended for 180 days or more after started. I hereby acknowledge that I have read this application and state that the information is correct and agree to comply with all applicable State of Minnesota Statutes and City of Eagan Ordinances. Applicant/Permitee: Signature slued B : Signature INSPECTION RECORD City of Eagan Permit Type: Sign 3830 Pilot Knob Rd Permit Number: EA181856 Eagan, MN 55122 Date Issued: 3/24/2023 (651)675-5675 www.cityofeagan.com Site Address: 3965 Eagan Outlets Pkwy Lot: 1 Block: 1 Addition: Paragon Addition PID: 10-56220-01-010 Use: Zumiez Sub Type: Building Sign Minds Inc. Work Type: New (651)450-7273 Description: Board nsuection Type Date Inspector Final Please call(651)675-5687 for a final inspection. New sign faces require separate permits. * Contractor is responsible for erosion control. * House#s required for final inspection. * 4-hour notice for permanent water turn-on for new building: 651-675-5200. ----------------- + For Office Us* { Permit W b J ». w � Permit Fee: $60 . 00 EAGAN � == j 3/22/2023 j I Date Received: l 3830 PILOT KNOB ROAD I EAGAN,MN 55122-1810 I_ JH l (651)675-5675 1 FAX: (651)675-5694 i Staff: I sianoerTnits Mcitvofeagan.com -- _ —� j 2023 SIGN PERMIT APPLICATION f �+ Submit one(1)application per building, pylon or monument sign. `f Submit one(1)application per pylon or monument sign tenant panel replacement. Submit two(2)copies of drawing showing proposed sign and site plan or building elevation showing location on property. Submit one(1)separate sign plan or letter containing the landlord/building owner's approval of the sign. Freestanding Signs exceeding 7 feet in height require a Commercial Building Permit ❖ Building Signs—Exposed electrical boxes or conduct shall be shielded from view by painting to match the building or sign band area, or enclosing within the sign raceway. All raceways shall be constructed of materials or painted to match the building or sign band area. Pylon signs are a Conditional Use and subject to all conditions, regulations,and fees required for conditional uses. r• Temporary Advertising Signs—Please complete both sides of the application. Appiications submitted via email are subject to an additional$0.25 per page printing charge which will be added to the permit fee. f• If any sign is placed,erected or installed without first obtaining a sign permit,the permit fee shall be the amount equal to two times the permit fee,per Section 11.70 Subd.28.1.2 Sign Type Dimensions of Sign &Sign Message Feet Inches Feet Inches Feet Inches Awning Length _ O x Height �_ C___ x Depth ,Y Building '1 ` Canopy Total Square Feet: Construction Lease Sign Message: Z- Monument Pylon location on Structure: iron -"a1i`` _��^Co'n l l Temporary Use Days Temporary Setback: • Has Electricity Other Elevation: Is Double Faced Date: 3/oral a 3 Applicant is: _ Owner Tenannt/ 1Sign Company/Contractor � Address where sign is to be located: ` S 4--r—C�/) �//C Tenant or Business Name: �� ► >L trY1 2 --- Tenant Contact Name: Telephone tf: Email // //�' Sign Company/Contractor: lG�It n�11C� f, _ Telephone#: �1��� 7 63gO Address: ! UcU i I7C 5.�! 1Z City: ! l State: /�! Zip:MI - Email: Property Owner )�� G{����c'rl��."tll CL!`�`L `J Telephone#: Jo Id ] Address: LS: City: State. Zip: Email: Fee: $25.00 #of Signs: (maximum of 3) Sizes of the Sign(s): 1. 2. 3. • Total Sq. Ft. of all signs: (All 3 signs cannot exceed 100 square feet) H WFirst Day of Placement: J WN Signs can be placed for 14 days out of a 60-day period which commences the first day a sign is CL placed. +� ZW Sign Permit Expiration Date: Z Sign permit(s)expires 60 days from first day of placement. t� V1 ■ m 14 Days Signs Will Be Placed: 4( Sign(s)will be attached to: building elevation pylon monument free standing WSigns must be attached to the building or to an existing monument or pylon sign. Oa CL U) Sign(s)will be attached using the following method: W0 ; Signs must be placed securely and in a sound manner to ensure safety of the public&in accordance with LL : reasonable standards employed by sign makers. Person responsible for placement/removal of sign: Telephone#: Email: Management Co. (if applicable) Telephone#: `. Approval of the building Owner or Management Company may be required. Check your lease or call your Management Company for additional information. You may.g.. ubscribe to receive an electronic notification from the City of proposed ordinances by signing up for an email update on the City's website at www.cityofeaaan.com/subscribe. CALL BEFORE YOU DIG. Contact Gopher State One Call at(651)454-0002 or www aooherstateonecall.ora for protection against underground utility damage. Contact Gopher State One Call 48 hours before you intend to dig to receive locates of underground utilities. I hereby acknowledge that I have read this application,state the appiication is correct,and agree to comply with Eagan,MN laws regulating construction and/placement. x ( r Applicant's Printe Name ,-,-."-Applicants Signatu FOR OFFICE USE Work Type: Description: Inspections Fees Change Existing —Aluminum pan _F.C.O.Aluminum _Footings $ 60 . 00 —CUP/Ftg. Ins. _Banner _„.„Halo-lit/Reverse Channel X Final $ Move X Hoard —LED/Electronic Copies$0.25/page $ 60 Days _Canister Plastic cutout TOTAL $ 60 . 00 X New _Cabinet/Logo _Plastic molded Channel lit letters Plastic Panel REVIEWED BY: — ane5 —Channel lit 1 raceway Routed JH Planning Flex Face �Vinyl graphics Building Inspections I I r I ' I I TYP. PIN-MNTD. HALO-LIT ILLUM. LOGOTYPE SECTION DETAILA-1 I i I c 1 I SCALE:N.T.S. 1 I FACE OI WIRING I-F ° MATERIAL: 118°ALUM.w/ROUTED-OUT LOGO. I-F:FEED SEE ELEC.NOTE.120V PRIMARY IN J-BOX BY OTHERS. 1 I COLOR/FINISH: BLACK/SATIN. I-P:PRIMARY 12awg FEED IN 0112°SEAL-TITE w/112°CONNECTORS. ©RETURN I-S:SECONDARY U.L.APPROVED CLASS 11 LOW VOLTAGE WIRE. j D DEPTH: 2-1/2°O.A. I-C:CONNECTOR 07/8°HOLE @ LEXAN w/01/2°PAIGE WALL BUSTER MATERIAL: 0.080°-0.090°ALUM. CONNECTOR&CONDUIT,WRAP EXPOSED CONDUIT I I I COLOR/FINISH: BLACK/SATIN. w/VINYL FINISHED TO MATCH FASCIA. I I I-S OD BACK OJ POWER SUPPLY I I MATERIAL: ACRYLIC 3/16°WHITE 112447. TYPE: REMOTE LED POWER SUPPLY HOUSED IN FRONT ACCESS I-C Q INSIDE OF CAN WEATHER-PROOF LED POWER SUPPLY BOX. Q COLOR: PRE-COAT WHITE. OV J-BOX TO HOUSE ELEC.CONNECTION TO PRIMARY TION VOLTAGE: E TYPE: 6500°K WHITE LEDS.SEE FABRICATOR NOTE. Q MOUNTING I F MECH.NOTE: M-1: SEE INSTALL NOTE.REQ'D.BLOCKING BY OTHERS. I J M-2: GRILL&TAP LEXAN FOR 10-24 ALLTHREAD wl 1-112°L x j 03/8°RIGID SPACER THRU EXISTING WALL TO BLOCKING. — Apomi ed As Noted-Upon receipt o!perm.Iron ory.'County M-2 honcaron may be unoeraken Sans mat Conor+to at L";ord SPACER FINISH: TO MATCH SIGN BAND FINISH. I Wmreras on Ines.dra"s I1 Instaltaton of sqn to be coordinated wtn Center Management not M-3: 10-24 BOLT&NUT. I to d sruV ousaross M-4: 112'x 1/2°ANGLE CLIPS. M-1 I MUst prmri0e Censer Management wnn copy of P@m t a nwance I C- Prior to mvasa ion&verity proper sWn ptacernertt prior to insist ©WEEP HOLE Center Management must v r+off on sgo'nstaRaoion wMn coy"*11a. TYPE: 1/8"W GAP @ B/0.LEXAN BACK. \ SIMON 1 I �lKNryMOU lC f yr^ NOTE: ICE AND WATER SHIELD DONUTS WITH WASHER — \ &NUT ARE REQUIRED TO ALLOW COMPRESSION TO — SIGNAGE FASCIA AT ALL BUILDING PENETRATIONS. — I 1.CUSTOMER G.C.TO PROVIDE ADEQUATE WOOD OR MTL.BLOCKING J 1.ALL ELECTRICAL COMPONENTS TO BE U.L.APPROVED. 1. PLACEMENT OF LIGHTING ELEMENTS FOR OPTIMUM ILLUMINATION J IN p CORRELATION WI FACADE FRAMING AS REQUIRED. Q 2. CUSTOMER IS RESPONSIBLE FOR ONE(1)120v/20a DEDICATED CIRCUIT OF SIGN TO BE DETERMINED IN PRODUCTION. U J 2. INSTALLER IS TO V.I.F.&PROVIDE THE PROPER NON-CORROSIVE _V w/GROUND PER SIGN TO WITHIN 6'OF SIGN. !U 2. MANUFACTURER&U.L.LABELS TO BE APPLIED&VISIBLE FROM THE O MOUNTING HARDWARE TO ENSURE SAFE INSTALLATION. 3.THIS SIGN IS INTENDED TO BE INSTALLED IN ACCORDING W/THE GROUND.LOCATED ON THE LAST CHANNEL LETTER OR END OF THE rn 3.ALL EXTERIOR FACADE PENETRATIONS TO BE WATERTIGHT. V REQUIREMENTS OF ARTICLE 600 OF THE NATIONAL ELECTRICAL CODE —Q. SIGN BOXTREESTANDING SIGN ALL ELECTRICAL Z_ 4. INSTALLATION TO MEET CURRENT N.E.C.,U.L.&LOCAL CODES. W AND/OR OTHER APPLICABLE LOCAL CODES.THIS INCLUDES PROPER LOCATION OF THE DISCONNECT SWITCH AFTER INSTALLATION SHALL W GROUNDING 8 BONDING OF THE SIGN. LL COMPONENTS ARE COMPLY WITH ARTICLE 600.6A) 1 OF THE NATION ELECTRICAL CODE TO BE UL APPROVED TRII NGLE 11 Azar Court • P.O.Box 24186 CLIENT 8 LOCATION LEAD NO. DATE REVIEWED BY SHEET NO. Baltimore,Maryland 21227 T:410-247-5300 • F:410 247-1944leZ WI EAGAN OUTLETS PKWY 5 of 7 TWIN CITIES PREM,OUT, 211841 3/16/2023 Reproduction In Whole Part �� TWIN #255 SM-PM DRAWN BY SEG.NO. SIGN SERVICES Prohibited without Express EAGAN,MN 55122 SA/BT JS Permission of Triangle S 8 S ©TSS NON-ILLUM. D/S BLADE SIGN w/ DIMN. LOGO IDB Verift and use preferred hanging method at center. SCALE:1"=r-0" QTY: ONE(1) AREA: 24"x 36"=6'0 SECT 1"DEEP D/S BLADE SIGN w/ B-1 3/8"DIMENSIONAL LOGO ID. SEE SECTION FOR DETAILS. All business signs mounted on a building shall be similar in design.Building facade signage on V.I.F.2'-0"O.C. multi-tenant buildings shall be evenly distributed T between all tenants. I I Building facade and fascia must be repaired I I and painted to cover all preexisting damage or ghosting from previous signs,and protect the structure from weather. Signs must be constructed and ated in a good Workmanlike manner of sound and sufficient —� materials and in accordance with all reasonable r' 318' standards employed by professional sign makers. 1 4 TYP ApWoved As NOW-Upon feosof ooma hom dylcourgy fabnU on may be uneMsdcM Srgna muff oerform to as Undford conMnarta on dress drawmga • inVARMon of sign to be 000rdm~wan C~Management na 2'-5" 1' to damp hueanss • Must Provide Censer Manager»M with copy of perms b mmxwKe 3'-0" pnor to natanstoon d verily proper sign Ososrmn p6w to instas • CeMer Mxrogement must"r off on syn eritaasbon when oompUen 04 TYR SIDE B ENDB SIMON 2 1 By Walton) at 6:41:53 PM, 312012023 TRII NGLE 11 Azar Court • P.O.Box 24188 CLIENT 8 LOCATION LEAD NO. DATE REVIEWED BY SHEET NO. Baltimore,Maryland 21227 T:410-247-5300 • F:410247-1944 TWIN CITIES PREM.OUT. 211841 3/16/2023 Re roduction In Whole or Part 3965 EAGAN OUTLETS PKWY 6 of 7 p SPACE#255 SM-PM DRAWN BY SEG.NO. SIGN SERVICES Prohibited without Express miez Permission of Triangle S&5 (D TSS EAGAN,MN 55122 SA/BT JS M-1 M-2 TYR NON-ILLUM. D/S BLADE SIGN w/ DIMN. LOGO SECTION DETAIL B-1 SCALE:N.T.S. M-3 QA FACE M-5 MATERIAL: 1/8"THK.ALUM. COLOR/FINISH: BLACK/SATIN. ©LOGO `J MATERIAL: 3/8"THK.ACRYLIC PLATE. COLOR/FINISH: I WHITE/SATIN. ©RETURN DEPTH: 1 1"O.A.DEEP COLOR/FINISH: I BLACK/SATIN. @ FRAME MATERIAL: 3/4"SQ.ALUM.TUBE, OM MOUNTING M-1: SEE INSTALL NOTE. M-2: V.I.F.MOUNTING HARDWARE/CRITERIA. M-4 M-3: VERSALOK FACE TO 1/2"x 1/2"SQ.ALUM,TUBE FRAME. M-4: VHB D/F TAPE 8 1/8"MTL.PINS. M-5: 1/4"ALUM.FLATBAR. Verily and use preferred hanguig method at center. Apptoved As Noted—Upon receipt of poring hom cry!ccunty fabrication may be undee'Jkon Sgns rn,9 colx!orm to aN Landlord cd""eMs Wt View drii mqs •tj Insta9Mgn of sqn to be coordinated wQh Center Management not to danxl hostess • Mut prwCe Center Manapsntem win coot'of pemA d mw.ance prw 10rataAason 6 verify proper sgri ptacement poor to instar. • C 1Mer Mano9emsnt mutt tips off on sego inst&#At*n whin complete I. CUSTOMER G.C.TO PROVIDE ADEQUATE WOOD OR MTL.BLOCKING SIMON•erw,u..ou+�r+s ,��,�. J IN CORRELATION W/FACADE FRAMING AS REQUIRED. 2. INSTALLER IS TO VI 8 PROVIDE THE PROPER NON-CORROSIVE By WaltonJ at 6:41:42 PM, 3/20/2023 Q MOUNTING HARDWARE TO ENSURE SAFE INSTALLATION. N 3.ALL EXTERIOR FACADE PENETRATIONS TO BE WATERTIGHT. Z 4. INSTALLATION TO MEET CURRENT N.E.C.,U.L.8 LOCAL CODES. LOCATION OF THE DISCONNECT SWITCH AFTER INSTALLATION SHALL COMPLY WITH ARTICLE 600.6(A)(1)OF THE NATION ELECTRICAL CODE TRI N G L E 11 Azar Court • P.O.Box 24186 CLIENT 8 LOCATION LEAD NO. DATE REVIEWED BY SHEET NO. Baltimore,Maryland 21227 leZ TWIN CITIES PREM.OUT. 211841 3/16/2023 T:410-247-5300 • F:410 247-1944 3965 EAGAN OUTLETS PKWY 7 Of 7 Reproduction In Whole Part �� SPACE#255 SM-PM DRAWN BY SEG.NO. SIGN SERVICES Prohibited without Express Permission of Triangle S$S ©TSS EAGAN,MN 55122 SA/BT JS