Loading...
EA181724 - Building - Lower Level - Issued Date 04/06/2023 PERMIT City of Eagan , , Permit Type: Building 3830 Pilot Knob Rd •o�;e®;®® Permit Number: EA181724 Eagan,MN 55122 • EAGAN - (651)675-5675 1111111111111 IN 11111111111111111111111111111111 www.cityofeagan.com * E A 1 8 1 7 2 4 * Date Issued: 4/6/2023 Site Address: 1098 Northview Park Rd Lot: 1 Block: 1 Addition: Lexington Parkview PID:10-45035-01-010 1111111111111111111 11111M Use: * 10 - 4S03S - 01 - 010 * Description: Sub Type: Lower Level Construction Type: V-B Work Type: Alteration Description: Census Code: 434-Residential Additions,Alterations Occupancy: IRC-1 Zoning: PD Square Feet: 0 Comments: Improvements to the home require smoke detectors in all bedrooms. Carbon monoxide detectors are required within 10 feet of all sleeping room openings in residential homes(Minnesota State Building Code). Separate plumbing and electrical permits required if such work is being done. Fee Summary: BL-Base Fee $182.80 0801.4085 Valuation: 7,660.00 BL-Plan Review 65% $118.82 0720.4222 Surcharge-Based on Valuation $4.00 9001.2195 Total: $305.62 Contractor: Owner: - Applicant - Brent J&Paige E Novey 1098 Northview Park Rd Eagan MN 55123 This permit shall be null and void if work does not start within 180 days of issuance,or if work is suspended for 180 days or more after started. I hereby acknowledge that I have read this application and state that the information is correct and agree to comply with all applicable State of Minnesota Statutes and City of Eagan Ordinances. I�� 'fir•-tom Applicant/Permitee: Signature sued B : Signature �M �U I .ECEIVEKas Lvv\ 4-11® MAR 16 7-------------------- I For Offlce Use 1 181724 1 ® ® ® ® BY: I Building Permit#: I I ®®®®q ®®00 Ek 0 ®s j S&WPermit#: EAGANwe®® �®®�► I I Permit Fee: D • 3/16/2023 Date Received: 3830 PILOT KNOB ROAD I EAGAN, MN 55122-1810 651 675-5675 FAX: 651 675-5694 1 I ( ) ( ) I Date Issued: j buildinoinsaectionsCa7ciNofeaaan.com I________________----- RESIDENTIAL BUILDING PERMIT APPLICATION Date: 3/11/23 Site Address: 1098 Northview Park Rd Unit#: Applicant is: 14 Owner ❑ Contractor Name: Brent Novey Homeowner Address: City:1098 Northview Park Rd Eagan State: MN Zi2: 55123 Phone: 5154507725 Email: bjnovey@gmail.com Description of work: Lower level finish Type,of, $25K PD, Lexington Parkview Work Construction Cost: Type of building: Single Family ❑ Townhome, of units ❑ Twin Home Company: Contact: Building Address: City: Contractor State: Zip: Phone: Email: License#: Expiration Date: aetM�r$ Company: Contact: Water Contractor Address: City: Required for State: Zip: Phone: Email: new=construction License#: Expiration Date: 14 1 understand that Plumbing, Mechanical, and Fire Suppression work require separate applications. NOTE:Plans and,supporting documents that you submit are considered,to,be public Information. Portions of the information maybe classified as non-public if you provide specific reasons that wo4l&permit the City to conclude"that they are trade secrets. CALL BEFORE YOU DIG. Contact Gopher State One Call at(651)454-0002 or www.aor)herstateonecall.ora for protection against underground utility damage. Contact Gopher State One Call 48 hours before you Intend to dig to receive locates of underground utilities. I hereby acknowledge that this Information is complete and accurate;that the work will be in conformance with the ordinances and codes of the City of Eagan; that I understand this Is not a permit, but only an application for a permit, and work is not to start without a permit; that the work will be in accordance with the approved plan In the case of work which requires a review and approval of tans. XBrent Novey X Applicant's Printed Name App ' Required Information for Site Address: 1098 Northview Park Rd Lower-Level Finish Permits 1. Show size of area to be finished and all dimensions on plan. 2. Show locations of all new and existing walls on plan. 3. Show use of rooms on plan (i.e., family room, bedroom, etc.) ❑ 4. Window locations, and information: Window Glass size of Type(casement,slider, location operable sash double hung, etc.) Window A Rec room 10"x27" Hopper Window B Rec room 10"x27' Hopper Window C Window D JZ 5. Exterior wall construction a) Size of studs/stripping: 2x4" b) Spacing of studs: 16" c) Type and thickness of insulation: R-13 d) Vapor barrier(i.e., 4 or 6 mil polyethylene): 4 mil polyethylene e) Wall covering (i.e., 1/inch sheetrock): 1/2"sheetrock 6. Interior wall construction a) Size of studs: some 2x4"some 2x6" b) Spacing of studs: 16" c) Wall covering (i.e., %inch sheetrock): 1/2"Sheetrock IZ 7. Ceiling covering (i.e., '/ inch or 5/8-inch sheetrock): 1/2"sheetrock �( 8. Smoke detector location (also show on plan): Hallway outside bathroom 9. Plumbing to be installed (check applicable): a. None b. '/z bath, existing rough-in ✓ c. %or full bath, existing rough-in d. '/z bath, new rough-in e. %or full bath, new rough-in ✓ f. Solid-based shower g. Tiled shower h. Other(please specify): 10. Type of water heater: ❑ Natural ❑ Power-vented I� 11. Heating to be installed (check applicable): ✓ a. Extended supply and returns back to trunk line b. Use existing with no changes c. Other(please specify): 12. Type and number of fireplaces being added: zero 13. Total square footage of finished basement area: 450 3830 PILOT KNOB ROAD I EAGAN, MN 55122 (651)675-5675 1 FAX: (651)675-5694 buildinoinspectionsOcitvofea4an.com If you have a hearing or speech disability, contact us through your preferred telecommunications relay service. FOR.OFFICE USE QNLY Site Address: 1098 Northview Park Rd Permit#: 181724 SUB TYPES Single Family _ Fireplace Lower Level 01 of_Plex _ Foundation _ Porch Deck _ Garage _ Pool WORK TYPES -)L New _ Repair _ Siding _ Retaining Wall _ Addition _ Fire Repair _ Reroof _ Move Building _ Alteration _ Water Damage _ Windows _ Demolish Building" Replace _ Egress Window _ Solar *Demolition of entire building-give PCA handout to applicant DESCRIPTION (p0 Calculated Valuation ��bOccupancy G '-- MCES System Plan Review [325016,4100% Code Edition MN 2G 2020 SAC Units Census Code Zoning FV City Water #of Units Stories Booster Pump #of Buildings Square Feet PRV Type of Construction �J�p _ Fire Suppression Required Separate Stormwater Management Permit Required REQUIRED INSPECTIONS Footings: New Addition Deck Meter Size: Foundation: Before Backfill Poured Wall Siding:_Stucco Lath _Stone Lath _Brick Framing: 1 Hour „Residential Alteration Roof:_Ice&Water _Final Braced Wall Framing/Blocking Erosion Control Braced Wall Sheathing(prior to house wrap) Pool:_Footings —Air/Gas Tests _Final Interior Braced Wall Panel(s) Retaining Wall:_Footings_Backfill_Final Firewalls Fire Suppression:_Rough In_Final Insulation Windows Radon Control Other: Drain Tile Grading Final/No C.O.Required Final/C.O.Required Y Reviewed By: 'e S , Building Inspector FEES Calculated Valuation (O�� 33( Base Fee I$Z. SD �, Plan Review $ �L —f State Surcharge 383 X `�2.0 ��0100 Met Council SAC City SAC Treatment Plant Water Supply&Storage S&W Permit&Surcharge Meter Radio Read Other: TOTAL $ 0.00 305.�z SMP8i. b „. r.F'a' L Y Egress Window shower O min min Existing Walls 30"di 15" 900 sq. Draft stop any gaps at top of wallmm t where air can flow from wall Fan required in baths 4" cavi to ceiling/floor floor cavi . ,3 h' � tY• with no window. exhausted outside O® SD i. SD-Smoke detector Bedroom O interconnected with other smoke 0 detectors CO-Carbon monoxid�_._._, detector Furring strips or studs Insulation(may exist on exterior) New Walls Poly Vapor Barrier Wall Finish Material Enclosed and accessible area under stair space must be protected by min.1/2"gyp. Bedroom { on walls and underside of stairs. Mechanical Egress Window 1"`•Sr 1P 3.S �qf t 1 Qa M' �, .'kl J 3'yr ?�;4F^ (��.,�y,; St ..• a. P,���,�a�.�tG<�'`"5�7��a°i.�� .'.§�a�-g: a,,.• r.'.��!'�.Ai"a�,��N.1� '.%°,��?. ..��.'..,«.p"N'.v""war. 3.�a.,.t�- T�G t'�� `•zbr ,��.,$t�� Basement Floor Plan 3 feet x 3 feet window well with affixed ladder required when well is deeper than 44" 5