EA181920 - Building - Deck - Issued Date 05/03/2023City of Eagan
3830 Pilot Knob Rd
Eagan, MN 55122
(651) 675-5675
www.cityofeagan.com
PERMIT
Permit Type: Building
®® Permit Number: EA181920
,,moee
® * E R 1 8 1 9 2 0*
Date Issued: 5/3/2023
Site Address: 995 Cliff Rd
Lot: 001 Block: 054 Addition: Section 26
PID:10-02600-54-010
Use: * 10-02600—S4-0 10*
Description:
Sub Type: Deck
Work Type: Alteration
Description: Replace 2 decks of same size
Census Code: 434 - Residential Additions, Alterations
Zoning: A
Square Feet: 0
Comments:
Construction Type: V -B
Occupancy: IRC -1
Fee Summary: (BL) Plan Review $215.64 0720.4222
Valuation: 16,740.00 BL - Base Fee $331.75 0801.4085
Surcharge - Based on Valuation $8.50 9001.2195
Total: $555.89
Contractor: - Applicant -
Owner:
Lindus Construction
Nancy L Sweet
879 Hwy 63
995 Cliff Rd
Baldwin WI 54002
Eagan MN 55123
(715) 684-4647
This permit shall be null and void if work does not start within 180 days of issuance, or if work is suspended for 180 days or more after
started.
I hereby acknowledge that I have read this application and state that the information is correct and agree to comply with all applicable State
of Minnesota Statutes and City of Eagan Ordinances.
Applicant/Permitee: Signature
du & 29n&ge
sued B : Signature
—,
j For Office Use
-------------
� I Building Permit #: I
� � I
�•��� 0.r j S&W Permit #
EAGAN
iPermit F IBJ 9 _I I
r I I
3830 PILOT KNOB ROAD I EAGAN, MN 55122-1 co �,�!® Date Received:
j
(651) 675-5675 i FAX: (651) 675-5694 I Date Issued:
buildinoinspections(&citvofeaaan.com L _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
+s 1c4
RESIDENTIAL ILD MT APPLICATION
11/28/22 995 Cliff Road
Date: Site Address: Unit #:
Applicant is: ❑ Owner 0 Contractor A
Vv -
Name: Nancy Sweet aA, 4-e
Address: 995 Cliff Rd City. Eagan
Homeowner
State: MN Zip: 55123 Phone: 651-454-484E Email:
Description of work: Remove existing decks and replace with new of same size
Type of
Construction Cost: 95,000
Work
Type of building: 0 Single Family ❑ Townhome, of units ❑ Twin Home
Company: Lindus Construction Contact: Cory Maxon
Building
Address: 879 US Hwy 63 City: Baldwin
Contractor
State: Zip: Phone: Email.. Wl 54002 800-873-1451 cory.maxon@lindusco.com
License #: BC728981 Ex iration Date: 03/31/2023
Sewer & Company: Contact:
Water
Contractor Address: City:
Required for State: Zip: Phone: Email:
new construction
License #: Fairation Date:
0 1 understand that Plumbing, Mechanical, and Fire Suppression work require separate applications.
NOTE: Plans and supporting documents that you submit are considered to be public Information. Portions of the
Information may be classified as non-public If you provide specific reasons that would permit the City to conclude that they
are trade secrets.
CALL BEFORE YOU DIG. Contact Gopher State One Call at (651) 454-0002 or www.000herstateonecall.oro for protection against underground utility
damage. Contact Gopher State One Call 48 hours before you intend to dig to receive locates of underground utilities.
I hereby acknowledge that this Information Is complete and accurate; that the work will be In conformance with the ordinances and codes of the City of
Eagan; that I understand this Is not a permit, but only an application for a permit, and work Is not to start without a permit; that the work will be In
accordance with the approved plan in the case of work which requires a review and approval of plans.
XCory Maxon 1401
Applicant's Printed Name Applicant's Signature
X
23
a
8
lateral load connection: Simpson DTTZ1
CL
995 Cliff rd
Required Information for Deck Permits
8
Site Address:
8
Dimensions of deck: 2-8x34, 2-6X40, 1-8X12
8
Height of deck from ground: 0-9'
Other approved type
8
Size of posts: 6X6
8
Spacing of posts:
10-12'
Joist to beam:
8
Footing diameter: Helical
8
Footing depth:
5'
*If sizes vary, leave blank and indicate individual sizes on plans.
*42" minimum for traditional
concrete footing. Specify if using engineered footings
(i.e., Diamond Pier) and provide installation instructions.
8
Size of beam(s): 5.5x11.5 treated
8
Drop or flush beam(s):
Drop
*Example: 2 — 2'x 12"
8
Cantilever on beam(s): 1811
CL
0
8
Size of joists: 2X10
8
Spacing of joists:
12" O.C.
0
8
Species of lumber for framing: KDAT SYP
8
Dimensions of floorboards: 5/4X6
8
Floorboard type:
AZEK vintage
8
Pattern of floorboards: J0
*i.e: perpendicular (90 degrees) to joists, 30/45/or 60 degrees to joists
8
Stair width: 511011, 3110"
8
Stair stringer spacing:
9" O.C.
8
Stair length: 6'
❑
Will the deck be built around a cantilevered area? (i.e., a bay with a patio door)
Yes / No
17
What type of floor framing will the ledger be attached to? (i.e., I joist, floor truss, 2"x 10", etc.)
2X10
0
Distance to property lines:
Cc3
i■]
Side 1: 122'
8
Rear:
367'
�
Side 2: 183'
E]
Other
c
Type
of hardware to be used:
Ledger board:
ledger board connection: GRK RSS 5/16"x4"
a
8
lateral load connection: Simpson DTTZ1
CL
Beam to posts:
8
Post cap (manufacturer/model) Simpson LPC6Z
❑
Through bolts (size)
V
❑
Other approved type
0
a
Joist to beam:
❑ Joist hanger
❑ Other
8 Any other hardware used: Simpson H2.5A Huricane tie
Final Checklist for Permit Submittal
Two (2) copies of plans that include:
8 Cross section view
8 Plan view
8 Stair framing view
8 Applicable supplemental information
Site plan, drawn to scale on survey or plat map, including:
Deck dimensions
8 Distance to property lines
SUB TYPES
Single Family
01 of _ Plex
Deck
WORK TYPES
_ New
_ Addition
_ Alteration
Replace
FOR OFFICE USE ONLY
Site Address: 995 Cliff Road
Fireplace
_ Foundation
Garage
Repair
_ Fire Repair
Water Damage
Egress Window
DESCRIPTION
Calculated Valuation I-TiO
Plan Review 1325% Rrl00%
Census Code
# of Units
# of Buildings
Type of Construction %—
Lower Level
Porch
Pool
_ Siding
_ Reroof
Windows
Solar
Permit #:
Retaining Wall
Move Building
_ Demolish Building"
*Demolition of entire building — give PCA
handout to applicant
Occupancy lgz' I MCES System
Code Edition ANiZO-2►10ItP SAC Units
Zoning A City Water
Stories Booster Pump
Square Feet PRV
Fire Suppression Required
Separate Stormwater Management Permit Required
REQUIRED INSPECTIONS
Footings: New Addition Deck
Foundation: Before Backfill Poured Wall
Framing: 1 Hour Residential Alteration
Braced Wall Framing/Blocking
Braced Wall Sheathing (prior to house wrap)
Interior Braced Wall Panel(s)
Firewalls
Insulation
Fireplace: _Rough In Air Test _Final
HVAC: Rough In Final
Radon Control
Siding: _Stucco Lath _Stone Lath _Brick
Roof: Ice & Water Final
Erosion Control
Pool: _Footings Air/Gas Tests _Final
Retaining Wall: _Footings _Backfill _Final
Fire Suppression: _Rough In _Final
Windows
Other:
$L. Final/No C.O. Required
Final/C.O. Required
Reviewed By: �s II.CS. Building Inspector
FEES Lower 1k
Calculated Valuation 1�pt71i'0 �7 x Z8�
Base Fee '75 15 .5)c L410 • S
Plan Review 215. Wq "?tr fTdCAA
State Surcharge
Met Council SAC
City SAC
Treatment Plant
Water Supply & Storage
S&W Permit & Surcharge
Meter
Radio Read
Other:
'so 3LLX g. S - 289
1,6.54 3
I�x 5 0. �c
Fr�� pulc
$3*1
TOTAL $ &W 555.85
m
m
"
c