Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
EA182363 - Building - Deck - Issued Date 05/17/2023
PERMIT City of Eagan Permit Type: Building 3830 Pilot Knob Rd '�' � '• EAGAN Permit Number: EA182363 Eagan,MN 55122 °--• -•-• (651)675-5675 .�- www.cityofeagan.com * E R 1 8 2 3 6 3 Date Issued: 5/17/2023 Site Address: 3692 Pond View Pt Lot: 15 Block: 01 Addition: Pond View Townhomes 1st PID:10-58361-01-150 Use: * 10 - 5836 1 - 0 1 - 150 * Description: Sub Type: Deck Construction Type: V-B Work Type: Replace Description: Census Code: 434-Residential Additions,Alterations Occupancy: IRC-3 Zoning: R-3 Square Feet: 0 Comments: Fee Summary: (BL)Plan Review $65.03 0720.4222 Valuation: 2,450.00 BL-Base Fee $100.05 0801.4085 Surcharge-Based on Valuation $1.50 9001.2195 Total: $166.58 Contractor: - Applicant _ Owner: Alexander Exteriors Lawrence A&Marlene Oberste 5100 Edina Industrial Blvd Suite 209 3692 Pond VIew Pt Minneapolis MN 55439 Eagan MN 55122-351 (612)5645106 This permit shall be null and void if work does not start within 180 days of issuance,or if work is suspended for 180 days or more after started. I hereby acknowledge that I have read this application and state that the information is correct and agree to comply with all applicable State of Minnesota Statutes and City of Eagan Ordinances. Applicant/Permitee: Signature ssued By": Signature —tet .j use For Otli�Use I Building Permit 1 • • I .5&W Permit#: IN ' EAGA' `�•� ••ter t ---'"_ 1 Date Received: t 3830 PILOT KNOB ROAD.1 EAGAN,MN 55122-1810 1 (851)67S-58751FAXt(651)675.5894 i Date issued rildinainsoections�c3tvnt�„.,.s.,oom I __-- _. �---- RESIDENTIAL BUI DING PERMIT APPLICATION 4/20/20 ��: site Address:3692 Pond View Point �untt#. Applicant Is: ❑Owner ®Contractor m Name:Mariana Oberste Hotneownor Address:3692 Pond View Point Cay. Eagan _ moberste@centurylink.ne s�rte: MN ZIP:55122 Phone:651-26$-662.. Emai� descriptio„of work- ReplacingDeck Type of 15000 Work Construction Cosh Type of building ❑Single'Family- ®Townhome, of units 3 Twln Home. Company,.Alexander Exteriors 952-258-9926 Contact Buildin8 Addm :5100 Edina industrial Blvd#209 , Edina ess Contractor state: MN Zip. Phone:55439 652-258-99Errant 2E Info a@alexanderexterior.s nn. rn SC723426 3131/2025- License Expiration bate: Sewer S Company: Contin Water Contractor Address: Ct1y Required for State: Zip: Phone: Email: new construction License o Expimlon Data: ® I understand that Plumbing,Mechanical,and Fire Suppression work require'separate applicatio s. NOTE,Pians and` o; documents that you submit are considered to ba public information. Pardons of the inf tnat ►h may pen-public ifyou provide spectflc"Means#W%"UM permit the City to conclude that th®y are:trade semr`ets CALL BEFORE YOU 010. Contact Gopher State One Call at(651)454-M or for protection against underground utility damage. Contact Gopher State One Cap 48 hours before you intend to dig to rem”lccaltas of underground utilities. I hereby acknowledge that this Information Is complete and accurate:that the work will be In carkrmance with the ordinances and.codes the City of Eagan;that I understand this Is not a permit, but only an application for a permit,and work is not to start without a permit*that the wo It will be in accordance with the approved plan In the case of work which requires a review and app of per. XAlyssa Kennedy Applicant's,Printed Name AA mfrs Stgrratatre L' JOR OFFICE USE 6kQY Site Address: 3692 Pond View Point Permit#: EAJ 82363 SUB TYPES _ Single Family _ Fireplace _ Lower Level _ 01 of_Plex _ Foundation _ Porch ✓ Deck _ Garage _ Pool WORK TYPES ✓ New _ Repair _ Siding _ Retaining Wall Addition _ Fire Repair _ Reroof _ Move Building Alteration _ Water Damage _ Windows _ Demolish Building* Replace _ Egress Window _ Solar *Demolition of entire building—give PCA handout to applicant DESCRIPTION Calculated Valuation $2450.00 Occupancy IRC-3 MCES System' Plan Review 025% 121100% Code Edition 202OMNRC SAC Units Census Code Zoning R-3 City Water #of Units Stories Booster Pump, #of Buildings Square Feet PRV, Type of Construction VB Fire Suppression Requiredli Separate Stormwater Management Permit Required! REQUIRED INSPECTIONS ✓ Footings: New Addition ✓ Deck Meter Size: Foundation: Before Backfill Poured Wall Siding:_Stucco Lath _Stone Lath Brick ✓ Framing: 1 Hour ✓ Residential Alteration Roof:_Ice&Water _Final Braced Wall Framing/Blocking Erosion Control Braced Wall Sheathing(prior to house wrap) Pool:_Footings Air/Gas Tests Final Interior Braced Wall Panel(s) Retaining Wall:_Footings_Backfill Final Firewalls REVIEWED FOR Fire Suppression:_Rough In_Final Insulation CODE COMPLIANCE Windows Radon Control ": Other: Drain Tile GradingEAGAN ✓ Final/No C.O. Required Derek Chide Final/C.O.Required 05M M2023 9:49:50 AM Reviewed By: BUILDING INSPECTIONS . Building Inspector FEES Calculated Valuation $2,450.00 Building a 15' x 8' 2" deck on the rgar elevation of the home. Footings to e Base Fee $100.05 placed inside lot, 6' 6" off rear house Plan Review $65.03 wall, and engineering has approved State Surcharge $1.50 up to a 2 ft cantilever into the Met Council SAC Drainage/Utility easement (Building code only allows a 1'8" cantilever).' City SAC Treatment Plant Deck: 15 x 8'2" = 122.5 sf Water Supply&Storage 122.5 sf x $20 = $2,450 S&W Permit&Surcharge Meter Radio Read Other: TOTAL $ 166.58 David Krieg 1479 Englert Road Eagan, MN 55122 May 1, 2023 RE: Deck Expansion Approval TO WHOM IT MAY CONCERN: As President of the Pond View Town Home Association, the Board has voted and approved the deck expansion request which will be a cantilever that extends 2' into the HOA property. The existing deck is TX 15' the request is for 9' X 15'. This plan was presented to City of Eagan by Alexander Exteriors for Mr. and Mrs. Oberste at 3692 Pond View Point, Eagan, Mn 55122. Regards, REVIEWED FOR CODE COMPLIANCE David Krieg President Pond View Town Home Association EAGAN 612-804-5970 © �°IN8�" INSPE BUILDINGG INSPECTIONS EA 182363 MAY 0 1 2xj CERTIFICATE OF SURVEY . . REVI WEE) '" for" .. GOOD VALUE HOMES EAGAN ' �' � ±' ' PROPOSED BUiLDfNG tD.E1%A'RONS-'' Footings are not afi0° Front of'hajss Aaron et"on Top of foundatlon allowed in osi,o is Geroge floor _ W koi t house �3__ easement. ENGIN ERING Lowest floor r- arrow denotes drainage direction.pet dsvelapment.. ...� demotes asxleting spot SIMMPlan- CPO 1,I Q a J Bow denotes proposed spot el=1anu uo v a u�.,� ' fh 5)b6 C}IMARK USED: NAIL /N Fbiwot Aix em *6 V o T .l Po�E �Asr a A'A 5 1 8°' �� OPPo I IZ LOTa l MASS C,414401416 :v pp e loom q UAI oQt16 'J, •33 ,w`.rta•� ��' ��t� �j�hvlr a•JG J / REVIEWED FOR Pp ,,fi�tt 11 0 . ODE COMPLIANCE ri ` , �� . EA IV EAGQANDelek 08/79/!073&•1822 Nd � � � � �. ude WILDING WSPECVONS �V i.{ EA 182363 O ��'o � ;.~� �6's" Q °� a• 17 New 15'x8'2" 0 vr� Deck �, �CQ• ° 3� • ` 8 .1 0 pIY� O � �pi�_•A'' . NOr ro WAS S�yicE �• f . � 4CiCPft • cs LEGAL DESCRIPTION =00/ Lots 15.16,17 dt•18. Block 1, POND VIEW pom s':Peo o 5>wv+ftq ST ADDITIONo accordin to the plat of . -)M4 " mord thereof. Dakota' County, Minnesota.- a';. • DENOTES IRON MONUMENT LSJ23945 23945 I hereby certify that this survey was °,•• D DENOTES WOOD HUB SET • ' prepared by me or under my direct s° 10' OFFSET LOT CORNER supervision, and that 1 am a duly CASHED UNE DENOTES DRAINAGELicensed Land Sunrayor under the AND UTILITY EASEMENT AS PER:PLAT. lows oft M eta. toe wunsulmam Mn __ _ -Donald"E._Si�ety MN 23945 o• Required Information for Deck Permits Site Address: 3692 Pond View Point/ EA182363 MAX 8'2" Depth Allowed ❑ Dimensions of deck: 9'x15' ❑ Height of deck from ground: 10' j ❑ Size of posts: 6x6 ❑ Spacing of posts: 71511 ❑ Footing diameter: 12 inch Helical ❑ Footing depth: 60" Helical *If sizes vary,leave blank and indicate individual sizes on plans. *42"minimum for traditional concrete footing. Specify if using engineered footings (i.e.,Diamond Pier)and provide installation instructions. ❑ Size of beam(s): 3- 2x10 ❑ Drop or flush beam(s): Drop *Example:2—2"x 12" a { ElCantilever on beam(s): 2' Ma)e 1' 8" Max Allowed c ❑ Size of joists: 2x10x16 ❑ Spacing of joists: 16 oc ❑ Species of lumber for framing: SYP#2 treated ❑ Dimensions of floorboards: 1 x6x16 ❑ Floorboard type: Fiberon Sancturay Composite ❑ Pattern of floorboards: 90 Degrees *i.e:perpendicular(90 degrees)to joists,30/45/or 60 degrees to joists ❑ Stair width: NA ❑ Stair stringer spacing: NA ❑ Stair length: NA ❑ Will the deck be built around a cantilevered area? (i.e.,a bay with a patio door) Yes No ❑ What type of floor framing will the ledger be attached to?(i.e.,I joist,floor truss,2"x 10",etc.) Floor Truss C �+ Distance to property lines: Incorrect, See Survey o m ; ❑ Side 1: 38,16" ❑ Rear: `� !i ❑ Side 2: 139.92" ❑ Other: i Type of hardware to be used: Ledger board: ❑ Ledger board connection: Ledger Loks a ❑ Lateral load connection: DTT1Z Simpson Final Checklist for Permit Submittal CL Beam to posts: Two(2)copies of plans that include: REVIEWED FOR CODE COMPLIANCE ❑ Post cap(manufacturer/model) AC6 ❑ Cross section view d � ❑ Through bolts(size) NA ❑ Plan view EAGAN c ❑ Other approved type ❑ Stair framing view DeMkCh` Joist to beam: E] Applicable supplemental information 0511M 9:41° a2^" ' BUILDING INSPECTIONS I ❑ Joist hanger 2x10 Traditional Site plan,drawn to scale on survey or plat map,including: ❑ Other ❑ Deck dimensions __ ❑ Any other hardware used: ❑ Distance to properly lines