Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
EA184455 - Plumbing - Commercial - Issued Date 06/08/2023
PERMIT City of Eagan ® ® Permit TI pe: Plumbing 3830 Pilot Knob Rd ,®.;® ® ®®® Permit Number: EA184455 ® ® Eagan,MN 55122 ®®®® ®®®® EAGAN (651)675-5675 iiiiiiiiiiiiiiiiiiiiiillillillillillillim www.cityofeagan.com * E R 1 8 4 4 5 5 * Date Issued: 6/8/2023 Site Address: 3650 Dodd Rd Lot: 001 Block: 001 Addition: Yorkton Ind Park South 2nd PID:10-88101-01-010 HFUMUMFURNIFffm Use: Terramax * 1 0 — 8 8 1 0 1 — 0 1 — 0 1 0 Description: Sub Type: Commercial Work Type: New Description: Water Softener Meter Size Meter Tyne Manufacturer Serial Number Remote Number Line Size Comments: Fee Summary: PL-Plumbing Commerical% $178.50 0801.4087 Valuation: 11,900.00 Surcharge-Based on Valuation $6.00 9001.2195 Total: $184.50 Contractor: - Applicant - Owner: Tri County Water Conditioning Inc West Publishing Co 325 Third Ave NW %Ryan LLC Dept 402 P O Box 65 PO Box 4900 Huchinson MN 55350 Scottsdale AZ 85261 320 587-2950 This permit shall be null and void if work does not start within 180 days of issuance,or if work is suspended for 180 days or more after started. I hereby acknowledge that I have read this application and state that the information is correct and agree to comply with all applicable State of Minnesota Statutes and City of Eagan Ordinances. Applicant/Permitee: Signature sZed B : Signature ------------------ FW Office use I • ;, i i 0 i P®rmlt#: 184455 j Q, I Permit Fee. —1 ► 0 1 EAGAIE I I ftt 3830 PILOT KNOB ROAD I EAGAN,MN 55122-1810 JUN 0 8 2023 nt --�a�saa (651)675-56751 FAx:(651)675-5694P I Payment Recvd. Yes Ido I Email:buildinainsaectionsOcltvofeaaan.com BY. IPlans:_Electronic _Paper j 2023 COMMERCIAL PLUMBING PERMIT APPLICATION ❑ Please submit one set of electronic plans via small Date: W'1 -*S Site address:—MQ 00dd 'I?A n MN G511% Tenant: Suite 6: Property Terramax David Crai ie Owner Name: g phone: 952-657-5592 Name: Tri County Water Conditioning License* WC802344 Contractor Address: 325 3rd Ave NW, PO Box 6:oity. Hutchinson site: MN zip: 55350 Phone.320-587-2950 Email: ashley@treatmywater.com New Construction Addition Modify Spam Replacement Repair Rebuild Work in Right-Of-Way Description of work: Installing Water Softener Type of Work Irrigation System( yes/_no)(_RPz i_Pvs) • Rain sensors required on irrigation systems • Avg.GPM (2°turbo required unless smaller size allowed by Public Works) Meter Required—Call Utilities at(651)675-5646 to verity tests passed prior to olckhm-up meter. Domestic:Size&Type Fire: 1 Average GPM High demand devices? Yes_No Flushometere Yes No COMMERCb4L FEES Contract Value$ 11 .9610 —X.014 $65.00 Permit Fee Minimum $ Permit Fes $65.00 PVB/RPZ Permit(Includes State Surcharge) Surcharge=Contract Value x$0.0005 $ Surcharge If the project valuation Is over$1 million,please call City for Surcharge $ TOTAL FEE The following fees may apply when Installing a new lawn Irrigation system or $ Water Pew connecting a now water service. $ Treatment Plant Contact the City's Engineering Department,(651)675-5646,for required fee amounts. $ Meter Fee $ Radio Read $ State Surcharge $ TOTAL FEE You may subscribe to receive an electronic notification from the City of proposed ordinances by signing up for an email update on the City's website at www.dtvofeaaan.com/subscribe. CALL BEFORE YOU DICT. Contact Gopher State One Call at(651)454-OCc02 or www.aoOmeWtoonmg.ora for protection agaI n:t underground utility damage. Contact Gopher State One Call 46 hours before you Intend to dig to receive locates of underground utilities. I hereby ardwowledge that this Information Is complete and accurate;that the work will be In conformance with the ordinances and codes of the City of Eagan:that I understand this Is not a permit,but only an application for a permit,and work is not to start without a permit;that the work will be in accordance with the approved plan M the case of work which requires a review and approval of plans. xAshley Weiler x Appacant's Printed Name Applicant's Signatuhl FOR OFFICE USE A Approved By: Date. elk(Z3 Required ImPectlons: wUnder Ground _Rough-in Air Test _Gas Test incl PRV Required:_Yes No Meter Related hams: Meter Size Radio Read Manometer Staff. Water Motor Fees Meter Size Fee 3/4" $300.00 $380.00 1-112" $1,380.00 2" $1,600.00 30 $2,000.00 40 $3,500.00 60 $6,500.00 Radio Meter Read $240.00 Additional Information • Radio Meter Reads are required on all new single.-family,multi family and commercial buildings. Boulevard irrigation systems may also require a radio read. • RPTs must be tested every year and rebuilt every five years. RPZ testing is submitted directly Online at www.gethydrosoft.com. Please call Hydrosoft customer service at(844)493-7641 or email Infgfthydroco Inc.com. • A minimum permit fee Is required per address for the following RPTs: new, rebuild,repair,&remove. • Water meters Include copper hom/strainer,remote wire,and touch-pad meter. • To schedule an Inspection of the Inside water Una and backflow preventer,call the City of Eagan Building Inspections Division(651)675-5675. • To arrange for water tum-on,call City of Eagan Utilities Department at(651)675-5200. 3830 PILOT KNOB ROAD I EAGAN,MN 55122 (651)675-56751 FAX:(651)675-5694 buiidinoinsoectionsOcitvofeagan.com If you have a hearing or speech disability,contact us through your preferred telecommunications relay service. 0 0 c m z D-- $ -' m0 ® C �- z z Z v LLz � NRWIN ILWd at o A Cosi MAN R ZO$j >> f§6N ' W MATERIALSANDCOMPONENTS USED m w E MANUFACTURE OF THI9 TlEAA SHALLLY WTTH E NATER SYSTEMS ES 30688 R Commercial Heavy Duty water System with 1-1/2" Eco Flow-Pack Valve Specifications Saft Dosage' . Grains Capadtya - - - Gra6ts at 4Oxtla,it 54, 0 72,0W 90,000 1080 14400 180.000 216.000 270.OD0 6 � 72.0M 96,000 120,0w 144AM 192,000 240,0OD 288.000 360.000 81bs./cu.R. 84.M 112,000 140AOW 168,000 224,000 28DAM 336,0 420OOD ) - - 101¢sJ 93,000 124.000 155.000 186,000 248,000 310AW 372,000 465,000 tzt tttt t _Qac./ - a2.1t 132A00 165.000 198,000 264.000 330PO 396,000 495,000 Resin Tank Siza On.) 17•x 58" 17'x 58' 17•x 72• 24'x72' 24'x 72' 24'x 72' 3'x 72' 30'x 72- Resin (Cu'N 3 _. 4 5 6 8_ 10 12 15 Co meedng Pipe Size 1-1/2'NPT 1-1/2"NPT 1-12"NPT 1-1/2'NPT 1-1/2'NPT 1-112'NPT 14/2"NPT 1-112'NPT M Une Co—rdon Sm 1-1/2•NPT i-112'NPT 1412•NPT 1-112•NPT 1-1/2'NPT 1421 NPT 1-12'NPT 14/2'NPT Salt Tank SbeOn.) 24'x50' 24'x50• 24"x SO" 31"xSl' 31•x51' 31'xSf' 41•x51• 41'x51' Salt TankCapadtq(fb) - 1.000 1AM 1,OD0 1.500 1,500 1M 2,500 2,500 I Operatf++i9 Presstae 30-125 psi 30-125 psi 30-125 psi -125 psi 30-125 psi30-125 psi 30-125 psi 30-125 psi 1 ^a TOMPOMWrat 3s-100•F 3S-100^F 35-100'F 35-1C0•F 35-10o'F 3S-1p0 F 35-100°F K-Uff Max Drain Flow(9Pm) 7 7 7 12 12 12 24 24 Re dtarge Water Used(94) 181 166 181 271 y 302 332 543 58B Max.Clear Wafer Iron' 20 ppm 20 ppm 20 ppm 20 ppm 20 plan 20 pAm 20 ppm P ----- T,. Elemi®IRatbV i 2412:C; 241fDC- 24VDC- 24VaC- 24VOC- 24VOC- 24VDC- 65 Watts 65 Wats 65 Watts 65 Watts 65 Wake 62549& 65 Wats K Wats - -- . Flow r8tm and Capacities shown are par tank A8 systerns aro available In sfngte,duplex,triplmc and 9rradPlex figurations, - 'Softdmages can be set to maugein desired efficlences or dtanged to auto adjustlng,salt-e8mWay or bailer option.See manual for deu& 'C MEM cepa ft Is for oamterctarent nsgenewdon d*Q parrposm The actual capacity old be 5%-10%greater then shown for each salt dosage. 'btMumed Mount�and�of�org B�°ud can reduce safsaning af8derrry and wpacftx PeRodic use of resin bed cleaner may be necessary C ar remove ms11 depend an a star wnd ions O e.pH. Operational Flows* Flo,,v Rate(GPIA)and Pressure(PSI)L,-:;s(AP) C7 S;akm3ss rOPM ' •'qPM 70 gpin 0 Foe tntvrntfwt us�ordy EWS1015S 16 AP 35 BP 7 6h10.5,aP 16AP 20.4 AP ©Not for M 81 theseltocr - - r E114+813155 2AP 4.5 AP 85 AP 12.5 AP g VA 18AP 19 AP 3396P Dm5daaafor EWS16155 25AP SAP 106P 14.5 AP 21AAP 26.9AP operation 379AP j� EWS1915S I AP 2 AP 46P BAP 12.4AP 1S.9 AP 23 9 AP EW525155 16P' 2.5 AP 5S AP &S 6P 12.96P 16.4 AP 249 6P 4. BAIMISS IOP 3AP 6AP 4AP 13.9AP 17.9AP 26.9 AP EVi153615S - 2 AP 4.5 AP 7 AP 10.9 AP 1394P 219 AP EW54515S - 2.5 AP SAP 6b AP 10.5 AP 14.9 DP 20 9 6P o s Code " ' ' • s rineTank Putfell • E EWS1015,EWS1315 17• 58' 64- 705' 24• SO- 44• ° EW51615 - c • 17' 72• 77' 83.5• 24' St!• 44• r EW51915.EW52515.EWS3215 ` 24' 72• 77' 1 835' 31' 51• 59• J EWS3615,E1NS4515 30' 72• Bt• 875• 41' I 51' 75' f Duplex-1 Brine Tank I Triplex-2 Brim Tanks I Quardplax-2 8r6ee Tanks