Loading...
EA184480 - Building - Deck - Issued Date 06/20/2023 PERMIT City of Eagan a ® ® ® Permit"': Building 3830 Pilot Knob Rd Permit Number: EA184480 Eagan, MN 55122 °®®® ®®®° EAGAN (651)675-5675 1111111111111111111111111111111111111111111111111 * E A 1 8 4 4 8 0 www.cityofeagan.com Date Issued: 6/20/2023 Site Address: 1165 Timbershore Lane Lot: 3 Block: 01 Addition: Timbershore 4th PID:10-76503-01-030 Use: * 1 0 — 7 6 5 0 3 — 0 1 — 0 3 0 Description: Sub Type: Deck Construction Type: V-B Work Type: New Description: Census Code: 434-Residential Additions,Alterations Occupancy: IRC-1 Zoning: PD Square Feet: 0 Comments: Fee Summary: (BL)Plan Review $65.03 0720.4222 BL-Base Fee $100.05 0801.4085 Valuation: 2,850.00 Surcharge-Based on Valuation $1.50 9001.2195 Total: $166.58 Contractor: Owner: - Applicant - Christine C Mulder 1165 Timbershore Ln Eagan MN 55123 This permit shall be null and void if work does not start within 180 days of issuance,or if work is suspended for 180 days or more after started. I hereby acknowledge that I have read this application and state that the information is correct and agree to comply with all applicable State of Minnesota Statutes and City of Eagan Ordinances. Applicant/Permitee: Signature ssued B : Signature LM bllb ;f ----- I0 I For Office Use I I Building Permit#: 184480 I ® ® ® ® P. I I ®®®�® ®®®®®0 j S&WPermit#: EAGAIT I Permit Fee:. b�a� I I Date Received: 6/8/2023 3830 PILOT KNOB ROAD I EAGAN, MN 55122-1810 (651)675-5675 IFAX: (651)675-5694 I I Date Issued: buildinginsaectionsCa)ciryofeagan.com i________________------ RESIDENTIAL BUILDING PERMIT APPLICATION Date: 06/08/2023 Site Address: 1165 Timbershore Drive Unit#: Applicant is: 14 Owner ❑ Contractor Name: Richard Haglund Homeowner Address: City:1165 Timbershore Drive Eagan State: MN Zi : 55123 Phone: 612.314.377 Email: richardhaglund@aol.com Description ofwork: Install deck on south elevation of home Type of $1,893.00 Work'' construction cost: PD, Timbershore Type of building: Single Family ❑ Townhome, of units ❑ Twin Home Company: Contact: Building Address: City: Contractor State: Zip: Phone: Email: License#: Expiration Date: sewer'& Company: Contact: Water Contractor Address: City: Required for State: Zip: Phone: Email: new construction License#: Ex iration Date: 1 understand that Plumbing, Mechanical, and Fire Suppression work require separate applications. NOTE: Plans and supporting documents that you submit are'ronsldiied to be public informationrticns of the information may be classified as non-public If you provide specific reasons that would permit the City to conclude that they are trade secrets. CALL BEFORE YOU DIG. Contact Gopher State One Call at(651)454-0002 or www.aoaherstateonecall.org for protection against underground utility damage. Contact Gopher State One Call 48 hours before you intend to dig to receive locates of underground utilities. I hereby acknowledge that this information is complete and accurate;that the work will be in conformance with the ordinances and codes of the City of Eagan; that I understand this is not a permit, but only an application for a permit, and work is not to start without a permit; that the work will be in accordance with the approved plan in the case of work which requires a review and approval of plans. XRichard Haglund xRichard Haglund Datv2lyI 23.06. 814:2 :1dH5'00' Dete:2023.06.08 14:24:11-0500' Applicant's Printed Name Applicant's Signature Required Information for Deck Permits site address: 1165 Timbershore Ln ® Dimensions of deck: 19' x 76" ® Height of deck from ground: 8' ® Size of posts: 6"X6" ® Spacing of posts: 7110" ® Footing diameter: ® Footing depth: Engineered footings on concrete slab If sizes vary,leave blank and indicate individual sizes on plans. "42"minimum for traditional concrete footing. Specify if using engineered footings (i.e.,Diamond Pier)and provide installation instructions. ® Size of beam(s): 2- 2"x8" ® Drop or flush beam(s): Flush Beams "Example:2—2"x 12" a 2 ® Cantilever on beam(s): 212" C 0 ® Size of joists: 2"x8" ® Spacing of joists: 16" on center m V ® Species of lumber for framing: Cedar Tone ® Dimensions of floorboards: 5/4X6" ® Floorboard type: Premium decking - cedar tone ® Pattern of floorboards: perpendicular to joists *i.e: perpendicular(90 degrees)to joists, 30/45/or 60 degrees to joists ❑ Stair width: NA ❑ Stair stringer spacing: NA ❑ Stair length: NA ❑ Will the deck be built around a cantilevered area? (i.e.,a bay with a patio door) Yes/No ❑ What type of floor framing will the ledger be attached to?(i.e.,1-joist,floor truss,2"x 10",etc.) 2"X8" Distance to property lines: ® Side 1: 20' ® Rear: 20' ® Side 2: 20' ❑ Other: Type of hardware to be used: Ledger board: ❑ Ledger board connection: Fasten Master Ledger Lok a ElLateral load connection: MiTek Joist hanger Final Checklist for Permit Submittal CL Beam to posts: Two(2)copies of plans that include: r ❑ Post cap(manufacturer/model) MiTek 6"x6"Triple Zink Post to beam connector ❑ Cross section view as ❑ Through bolts(size) 1/2"-13x8" ❑ Plan view > Other approved❑ pp type ❑ Stair framing view ,o; n`. Joist to beam: ❑ Applicable supplemental information ❑ Joist hanger Galvanized Joist Hanger Site plan,drawn to scale on survey or plat map,including: ❑ Other ❑ Deck dimensions ❑ Any other hardware used: ❑ Distance to property lines FOR OFFICE USE ONLY Site Address: 1165 Timbershore Drive Permit#: 184480 SUB TYPES Single Family _ Fireplace _ Lower Level 01 of_Plex _ Foundation _ Porch /Deck _ Garage _ Pool WORK TYPES New _ Repair _ Siding _ Retaining Wall _ Addition _ Fire Repair _ Reroof _ Move Building Alteration _ Water Damage _ Windows _ Demolish Building" Replace _ Egress Window _ Solar *Demolition of entire building—give PCA handout to applicant DESCRIPTION _ Calculated Valuation Occupancy Mec- i MCES System Plan Review 0250/6,0100% Code Edition MNQc.dod SAC Units Census Code Zoning City Water #of Units Stories Booster Pump #of Buildings Square Feet PRV Type of Construction Ya Fire Suppression Required Separate Stormwater Management Permit Required REQUIRED INSPECTIONS Footings: New Addition ae--- Deck Meter Size: Foundation: Before Backfill Poured Wall Siding:_Stucco Lath _Stone Lath _Brick Framing: 1 Hour /Residential Alteration Roof:_Ice&Water _Final Braced Wall Framing/Blocking Erosion Control Braced Wall Sheathing(prior to house wrap) Pool:_Footings _Air/Gas Tests _Final Interior Braced Wall Panel(s) Retaining Wall:_Footings_Backfill_Final Firewalls Fire Suppression:_Rough In_Final Insulation Windows Radon Control Other: Drain Tile Grading _� Final/No C.O. Required Final/C.O. Required Reviewed By: 1\ . Ale 1.50-1\ , Building Inspector FEES IAlf Qee lc Calculated Valuation Base Fee Plan Review State Surcharge Met Council SAC City SAC Treatment Plant Water Supply&Storage S&W Permit&Surcharge Meter Radio Read Other: TOTAL $ 0.00 Required Information for Deck Permits Site Address: 1165 Timbershore Ln r ® Dimensions of deck: 19' x 76" ® Height of deck from ground: 8' ® Size of posts: 6"x6" ® Spacing of posts: 7'10" ® Footing diameter: Minimum footing sizes for all ® Footing depth: 42° min. Engineemd feetings en ea three footings: *If sizes vary,leave blank and indicate individual sizes Square-12"sides *42"minimum for traditional concrete footing. Specify if using engineered footings Round-14"diameter (i.e.,Diamond Pier)and provide installation instructions. ® Size of beam(s): 2- 2"x8" ® Drop or flush beam(s): Flush Beams *Example:2—2"x 12" N I C a ® Cantilever on beam(s): ® Size of joists: 0 2"x8" ® Spacing of joists: 16" on center ® Species of lumber for framing: Cedar Tone ® Dimensions of floorboards: 5/4x6" ® Floorboard type: Premium decking - cedar tone ® Pattern of floorboards: perpendicular to joists *i.e:perpendicular(90 degrees)to joists,30/45/or 60 degrees to joists ❑ Stair width: NA ❑ Stair stringer spacing: NA ❑ Stair length: NA ❑ Will the deck be built around a cantilevered area? (i.e.,a bay with a patio door) Yes/No ❑ What type of floor framing will the ledger be attached to?(i.e.,I joist,floor truss,2"x 10",etc.) 2"x8" A C > Distance to property lines: ® Side 1: 20' ® Rear: 20' y ® Side 2: 20' ❑ Other: c See attachment for Ledger See attachment for Simpson Lok installation requirements. Type of hardware to be used DTT1 Z example.Joist hangers not sufficient for lateral load restraint. Ledger board: If using post caps,use in pairs (2 per post-front and back) ❑ Ledger board connection: Fasten Master Ledger Lok CL ElLateral load connection. I Final Checklist for Permit Submittal R Beam to posts: Two(2)copies of plans that include: REVIEWED FOR CODE COMPLIANCE ❑ Post cap(manufacturer/model) MTek 6"x6"Triple Zink Post to beam connector ❑ Cross section view _ �+ ❑ Through bolts(size) 1/2"-13x8" ❑ Plan view d — ❑ Other approved type ElStair framing view EAGAN IL Joist to beam: Applicable supplemental information BUI�LD�= NS ❑ Joist hanger Galvanized Joist Hanger Site plan,drawn to scale on survey or plat map, including: ❑ Other ❑ Deck dimensions 0 Any other hardware used: ❑ Distance to properly lines 1 •• • • 02 30 1 •�' _ _ 40 ll on _ 2 I m ti 1 Im 3h-t- - I l' T MQER5HaRES 4TH' AN • as � �. N. � . � I + 41 4 - 1 = 1 4 = s •� 393 u ; uDo A • � * � � � • i 1 • �+ 4 C • • B ; ; ar I • � • i • � n4 ` • 0, 2 1 3 ,� r fa t + 3 ti 2 3 FE-3 . .. . .. .. .. . . •s. , • . . . . . . . . • • u Ski New Deck •. •• a R K) f� t REVIEWED FOR . .� 1 CODE COMPLIANCE ••' '•• •••• ••• •• •• •� p :S • • • A 2. EAGAN •:• WWI— I C D 0611W=1@43:08 AM BUILDING INSPECTIONS