Loading...
EA183274 - Building - Deck - Issued Date 06/23/2023 PERMIT City of Eagan , ® ® ® Permit Type: Building 3830 Pilot Knob Rd �m0®® ®®®®'® Permit Number: EA183274 Eagan, MN 55122 EAGAN (651)675-5675 1111111111111 IN 11111111111111111111111111111 IN www.cityofeagan.com * E R 1 8 3 2 7 4 * Date Issued: 6/23/2023 Site Address: 3801 North Ridge Dr Lot: 1 Block: 1 Addition: Gardenwood Ponds PID:10-28800-01-010 Use: * 10 - 28800 - 0 1 - 0 10 * Description: Sub Type: Deck Construction Type: V-B Work Type: Alteration Description: Census Code: 434-Residential Additions,Alterations Occupancy: IRC-1 Zoning: R-1 Square Feet: 0 Comments: Fee Summary: (BL)Plan Review $54.28 0720.4222 Valuation: 2,000.00 BL-Base Fee $83.50 0801.4085 Surcharge-Based on Valuation $1.00 9001.2195 Total: $138.78 Contractor: - Applicant - Owner: Lake Country Home Improvement LLC Andrew C&Amanda Lancette 4201 County Trail W 3801 North Ridge Dr Jordan MN 55352 Eagan MN 55123 (952)529-6425 This permit shall be null and void if work does not start within 180 days of issuance,or if work is suspended for 180 days or more after started. I hereby acknowledge that I have read this application and state that the information is correct and agree to comply with all applicable State of Minnesota Statutes and City of Eagan Ordinances. Applicant/Permitee: Signature sued B : Signature -------------- jFor Office Use 4 l Building Permit#: X32I I ®® S&W Permit#: EAGAN I Permit Fee: I I Date Received: 3830 PILOT KNOB ROAD I EAGAN, MN 55122-19ILDING ECEI®/E 651 675-5675 FAX: 651 675-5694 ' � ) � � ) I Date Issued: j buildinainspectionsccDcitvofeaaan.com JUN 0 1 2023 I RESIDENTIAL PE IT APPLICATION Date: 5/31/2023 Site Address: 3801 N RIDGE DR Unit#: Applicant is: ❑ Owner ❑ Contractor P_ 6-A" '1W a 00( Fonds Name: ANDY LANCETTE Homeowner Address: City:3801 N RIDGE DR EAGAN State: MN Zip: 55123 Phone: 651.216.37 Email: aclancette@gmail.com Description of work: ADDING RAILS,PRIVACY WALL & STAIRS TO EXISTING DECK Type of Work Construction Cost: 11 ,000 Type of building: 0 Single Family ❑ Townhome, of units ❑ Twin Home Company: LAKE COUNTRY HOME IMPORVEM& contact: SHANNON KUIPER Building Address: 4201 COUNTRY TRAIL W City: JORDAN Contractor State: Zip: Phone:MN 55352 612.499.14 Email: SHANNON.LCHI@OUTLOOK.COM BC780656 License#: E jlo Sewer& Company: TS 2- Sig- 67 S Water Contractor Address: II L d e COu,�.1Frs ���t. Required for State: Zip: Phone: N x new construction (^,Prefie'",e45 License#: E 5�,►at I . C6r� ❑ I understand that Plumbing, Mechanical,and Fire S (rCe L&,,. AJWSo.- irate applications. NOTE: Plans and supporting documents that you submit are considered to bq.pu c n orma on. Portions of the Information may be classified as non-public if you provide specific reasons that would permit the City to conclude that they .are trade secrets. CALL BEFORE YOU DIG. Contact Gopher State One Call at(651)454-0002 or www.aopherstateonecall.ora for protection against underground utility damage. Contact Gopher State One Call 48 hours before you intend to dig to receive locates of underground utilities. I hereby acknowledge that this information is complete and accurate;that the work will be in conformance with the ordinances and codes of the City of Eagan; that I understand this is not a permit, but only an application for a permit, and work is not to start without a permit; that the work will be in accordance with the approved plan in the case of work which requires a review and approval of plans. S4-11— Digitallysigned by SHANNON XSHANNON KUIPER X KUIPER Geta:2023.05.31 17:37:47-05'00' Applicant's Printed Name Applicant's Signature FOR OFFICE USE ONLY Site Address: 3801 N RIDGE DR Permit#: SUB TYPES Single Family _ Fireplace _ Lower Level _ 01 of_Plex _ Foundation _ Porch Deck _ Garage _ Pool WORK TYPES _ New _ Repair _ Siding _ Retaining Wall Addition _ Fire Repair _ Reroof _ Move Building _ Alteration _ Water Damage _ Windows _ Demolish Building" Replace _ Egress Window _ Solar 'Demolition of entire building-give PCA handout to applicant DESCRIPTION Calculated Valuation Occupancy MCES System Plan Review [325% 11100% Code Edition SAC Units Census Code Zoning City Water #of Units Stories Booster Pump #of Buildings Square Feet PRV Type of Construction Fire Suppression Required Separate Stormwater Management Permit Required REQUIRED INSPECTIONS Footings: New Addition Deck Meter Size: Foundation: Before Backfill Poured Wall Siding:_Stucco Lath _Stone Lath _Brick Framing: 1 Hour Residential Alteration Roof:_Ice&Water _Final Braced Wall Framing/Blocking Erosion Control Braced Wall Sheathing(prior to house wrap) Pool:_Footings —Air/Gas Tests _Final Interior Braced Wall Panel(s) Retaining Wall:_Footings_Backfill_Final Firewalls Fire Suppression:_Rough In_Final Insulation Windows Radon Control Other: Drain Tile Grading Final/No C.O.Required Final/C.O.Required Reviewed By: , Building Inspector FEES Calculated Valuation Base Fee Plan Review State Surcharge Met Council SAC City SAC Treatment Plant Water Supply&Storage S&W Permit&Surcharge Meter Radio Read Other: TOTAL $ 0.00 FOR OFFICE USE ONLY Site Address: 3801 N Ridge Dr. Permit#: EA183274 SUB TYPES Single Family _ Fireplace _ Lower Level _ 01 of_Plex _ Foundation _ Porch ✓ Deck _ Garage _ Pool WORK TYPES _ New _ Repair _ Siding _ Retaining Wall Addition _ Fire Repair _ Reroof _ Move Building ✓ Alteration _ Water Damage _ Windows _ Demolish Building* Replace _ Egress Window _ Solar *Demolition of entire building—give PCA handout to applicant DESCRIPTION Calculated Valuation $2,000.00 Occupancy IRC-1 MCES System Plan Review 025% 0100% Code Edition 202OMNRC SAC Units Census Code Zoning R-1 City Water #of Units Stories Booster Pump #of Buildings Square Feet PRV Type of Construction VB Fire Suppression Required Separate Stormwater Management Permit Required REQUIRED INSPECTIONS Footings: New Addition Deck Meter Size: Foundation: Before Backfill Poured Wall Siding:_Stucco Lath _Stone Lath _Brick ✓ Framing: 1 Hour of Residential Alteration Roof:_Ice&Water _Final Braced Wall Framing/Blocking Erosion Control Braced Wall Sheathing(prior to house wrap) Pool:_Footings Air/Gas Tests _Final Interior Braced Wall Panel(s) Retaining Wall:_Footings_Backfill_Final Firewalls REVIEWED FOR Fire Suppression:_Rough In_Final Insulation CODE COMPLIANCE Windows Radon Control %;%, Other: Drain Tile Grading EAGAN ✓ Final/No C.O.Required DerekQuua➢e Final/C.O. Required 09/232023 9:38:59 AM Reviewed By: BUILDING INSPECTIONS , Building Inspector FEES Calculated Valuation $2,000.00 Existing Deck 24" from Base Fee $83.50 grade: Adding privacy Plan Review $54.28 State Surcharge $1.00 wall, guard rails, and Met Council SAC stairs. City SAC Treatment Plant Water Supply&Storage S&W Permit&Surcharge Min valuation $2,000 Meter Radio Read Other: TOTAL $138.78 Any changes to plans shall be submitted for Reviewed plans must remain available, review prior to implementation. on site, at all times. REVIEWED FOR CODE COMPLIANCE EAGAN Derek Qualle M2=023 9:02:66 Address must be posted during construction. BUILDING INSPECTIONS Required Information for Deck Permits Site Address: 3801 N RIDGE DR EA183274 ❑ Dimensions of deck: EXISTING-NO CHANGE ❑ Height of deck from ground: ❑ Size of posts: EXISTING-NO CHANGE ❑ Spacing of posts: EXISTING-NO CHANGE ❑ Footing diameter. EXISTING-NO CHANGE ❑ Footing depth: EXISTING-NO CHANGE 'If sizes vary,leave blank and Indicate Individual sizes on plans. •42°minimum for traditional concrete footing. Specify if using engineered footings (i.e.,Diamond Pier)and provide Installatlon Instructions. ❑ Size of beam(s): EXISTING-NO CHANGE ❑ Drop or flush beam(s): EXISTING-NO CHANGE 'Example:2—2'x 12" m m d ❑ Cantilever on beam(s): EXISTING-NO CHANGE o ❑ Size of joists: EXISTING-NO CHANGE ❑ Spacing of joists: EXISTING-NO CHANGE ❑ Species of lumber for framing:Stringers Green Treated AC2-Wall Red Cedar red cedar e ❑ Dimensions of floorboards: treads are 5/4 x 6 decking ❑ Floorboardtype ; ❑ Pattern of floorboards: EXISTING-NO CHANGE *Le:perpendicular(90 degrees)to joists,30/45/or 60 degrees to joists if ❑ Stair width: 48" ❑ Stair stringer spacing: 12 ❑ Stair length: 4 risers,3 treads ❑ VIII the deck be built around a cantilevered area? p.e.,a bay with a patio door) Yes/No ❑ What type of floor framing will the ledger be attached to?(i.e.,I jolst,floor truss,2"x 10',etc.) EXISTING-NO CHANGE r e Distance to property lines: c io v ❑ Side 1: EXISTING-NO CHANGE ❑ Rear. EXISTING-NO CHANGE W ❑ Side 2: EXISTING-NO CHANGE ❑ Other: EXISTING-NO CHANGE u C I Type of hardware to be used: � Ledger board: Adjusted per conversation with contractor 'j ❑ Ledger board connection: EXISTING-NO CHANGE a. ❑ Lateral load connection: EXISTING-NO CHANGE Final Checklist for Permit Submittal a —-----— --- CL Beam to posts: Two(2)copies of plans that Include: 5 ❑ Post cap(manufacturer/model) EXISTING-NO CHANGE ❑ Cross section view v [3 Through bolts(size) EXISTING-NO CHANGE ❑ Plan view ❑ Other approved type EXISTING-NO CHANGE ❑ Stair framing view o d Joist to beam: ❑ Applicable supplemental Information ❑ Joist hanger EXISTING-NO CHANGE Site plan,drawn to scale on survey or plat map,Including: ❑ Other ❑ Deck dimensions r ❑ Any other hardware used: EXISTING-NO CHANGE 0 Distance to property lines