EA183112 - Building - Deck - Issued Date 06/30/2023PERMIT
City of Eagan
®®Permit
Type:
Building
3830 Pilot Knob Rd
Eagan, MN 55122
®m®®® ®®®: ®
®®®® ®•mmE Ato IN
Permit Number:
EA183112
(651) 675-5675
111111111111
www.cityofeagan.com
* E R 1 8 3 1
1 2
Date Issued:
6/30/2023
Site Address: 4867
Knottingham Cir
Lot: 4 Block: 2
Addition: Brittany 8th
PID:10-15007-02-040
111111111111111 IN 11111111111111111111111111
11M
Use:
* 10— 15007-02-040*
Description:
Sub Type: Deck
Construction Type:
V -B
Work Type: New
Description:
Census Code: 434 - Residential Additions, Alterations Occupancy:
IRC -1
Zoning: R-1
Square Feet: 0
Comments:
Fee Summary:
(BL) Plan Review $108.06
0720.4222
Valuation: 6,500.00
BL - Base Fee $166.25
0801.4085
Surcharge - Based on Valuation $3.50
9001.2195
Total: $277.81
Contractor: - Applicant - Owner:
Innovative Building & Design LLC Scott B Bjerva
P.O. Box 490298 4867 Knottingham Cir
Blaine MN 55449 Eagan MN 55122--279
(612) 808-6025
This permit shall be null and void if work does not start within 180 days of issuance, or if work is suspended for 180 days or more after
started.
I hereby acknowledge that I have read this application and state that the information is correct and agree to comply with all applicable State
Df Minnesota Statutes and City of Eagan Ordinances.
Applicant/Permitee: Signature
sued B . Signature
3830 PILOT KNOB ROAD I EAGAN, MN 55122-1810
(651) 675-56751 FAX: (651) 675-5694
buildinginsoecbonsC&-citvofeaQan.com
ECEI\fE
MAY 2 4 2073
-----------
l
,,:Eagan
For Office Use
l
I
I Building Permit #:
I
183112
l
I
S&W Permit it
I
I
Permit
pp I
I
5/24/23 I
Date Received:
I
Date Issued:
I
I
--------------------
---------------------
RESIDENTIAL BUILDING PERMIT APPLICATION
Date: 5/23/23 Site Address: 4867 Knottingham Circle Unit #:
Applicant is: ❑ Owner 0 Contractor
Name: Scott Bjerva 8r Deb Lalonde
Address: 4867 Knottingham Corcle
State: mn zip: 55122 Phone: 6128396322 Email:
Description of work: deck
Construction Cost: 29,465
of building: 0 Single Family ❑ Townhome,
Company: Innovative building and design
Address: 1543 92nd In ne
State: mn Zip: 55449
.. _ _ _ _ _ _. bC635372
Company:
Address:
City:Eagan
R-1, Brittany
of units ❑ Twin Home
Contact: Bob Spindler
Phone: 6514859887 Email;
State: Zip: Pho►
0 1 understand that Plumbing, Mechanical, i
joy
PCZ 290
_Citi: Blaine
bob@innovativebuilding.com
.quire separate applications.
hforiiriatlon3` Porttoris ofi:the
CALL BEFORE YOU DIG. Contact Gopher State One Call at (651) 454-0002 or www.gooherstaWnecall.org for protection against underground utility
damage. Contact Gopher State One Call 48 hours before you Intend to dig to receive locates of underground utilities.
I hereby acknowledge that this Information Is complete and accurate; that the work will be In conformance with the ordinances and codes of the City of
Eagan; that I understand this is not a permit, but only an application for a permit, and work Is not to start without a permit; that the work will be in
accordance with the approved pian in the case of work which requires a review and approval of plans.
XBob Spindler X r --
Applicant's Printed Name Applicant's nate
SUB TYPES
Single Family
— 01 of _ Plex
Deck
WORK TYPES
_ New
Addition
Alteration
_ Replace
DESCRIPTION
Calculated Valuation
Plan Review
Census Code
# of Units
# of Buildings
Type of Construction
FO C,O_Ni�Y
Site Address: 4867 Knottingham Circle
_ Fireplace
_ Foundation
_ Garage
T Repair
_ Fire Repair
Water Damage
_ Egress Window
❑25% ❑100%
REQUIRED INSPECTIONS
` Lower Level
— Porch
Pool
_ Siding
Reroof
_ Windows
— Solar
Occupancy
Code Edition
Zoning
Stories
Square Feet
_ Footings: New Addition Deck
_ Foundation: Before Backfill Poured Wall
_ Framing: 1 Hour Residential Alteration
Braced Wall Framing/Blocking
Braced Wall Sheathing (prior to house wrap)
Interior Braced Wall Panel(s)
Firewalls
Insulation
Radon Control
Drain Tile
Grading
Permit #: 183112
— Retaining Wall
_ Move Building
Demolish Building*
"Demolition of entire building — give PCA
handout to applicant
MCES System
SAC Units
City Water
Booster Pump
PRV
Fire Suppression Required
Separate Stormwater Management Permit Required
Meter Size:
Siding: _Stucco Lath ,_Stone Lath _Brick
Roof: _Ice & Water _Final
Erosion Control
Pool: _Footings Air/Gas Tests _Final
Retaining Wall: _Footings _Backfill _Final
Fire Suppression: _Rough in _Final
Windows
Other:
Final/No C.O. Required
Final/C.O. Required
Reviewed By: , Building Inspector
FEES
Calculated Valuation
Base Fee
Plan Review
State Surcharge
Met Council SAC
City SAC
Treatment Plant
Water Supply & Storage
S&W Permit & Surcharge
Meter
Radio Read
Other:
TOTAL $ 0.00
SUB TYPES
_ Single Family
_ 01 of _ Plex
✓ Deck
WORK TYPES
✓ New
_ Addition
_ Alteration
Replace
FOR OFFICE USE ONLY
Site Address: 4867 Knottingham Cir
_ Fireplace
Foundation
Garage
_ Repair
Fire Repair
_ Water Damage
_ Egress Window
Calculated Valuation $ 6,500.00
Plan Review 025% 0100%
Census Code
# of Units
# of Buildings
Type of Construction VB
REQUIRED INSPECTIONS
Lower Level
Porch
_ Pool
Siding
Reroof
Windows
Solar
Permit #• EA183112
Retaining Wall
_ Move Building
_ Demolish Building*
"Demolition of entire building — give PCA
handout to applicant
Occupancy 1RC-1 MCES System
Code Edition 202OMNRC SAC Units
Zoning R-1 City Water
Stories Booster Pump
Square Feet PRV
Fire Suppression Required
Separate Stormwater Management Permit Required
✓ Footings: New Addition ✓ Deck
_ Foundation: Before Backfill Poured Wall
✓ Framing: 1 Hour ✓ Residential Alteration
Braced Wall Framing/Blocking
_ Braced Wall Sheathing (prior to house wrap)
_ Interior Braced Wall Panels)
_ Firewalls
_ Insulation
Radon Control
_ Drain Tile
Grading
REVIEWED FOR
)DE COMPLIANCE
EAGAN
Derek Qualle
08P3M=12:1425 PM
Meter Size:
Siding: _Stucco Lath _Stone Lath _Brick
Roof: _Ice & Water _Final
Erosion Control
Pool: _Footings Air/Gas Tests _Final
Retaining Wall: _Footings _Backfill _Final
Fire Suppression: _Rough In _Final
Windows
Other:
✓ Final/No C.O. Required
Final/C.O. Required
Reviewed By: , Building Inspector
FEES
Calculated Valuation $ 6.500.00
Base Fee
Plan Review
State Surcharge
Met Council SAC
City SAC
Treatment Plant
Water Supply & Storage
S$W Permit & Surcharge
Meter
Radio Read
Other:
$166.25
$106.06
$ 3.50
TOTAL $ 277.81
Building a 21'x 13' Deck, with
stairs, on rear elevation of home
13x4=52sf
21 x 13 = 273 sf
52 + 273 = 325sf x $20 = $6,500
Tj11*efson'B1Ajc1ers Inc. '
Or. 116a2
A ,
188-22
scala: 111:30' JACKSON . SURVEYORS
s Denotes Iron
1111111111=011iO UM M LAM/8 OR ATAT5 W M01111000TA
— 49Calaage 4 Utility Eassmat
Q00.0 :Bsisting Slay.
8816 EMT =* STR88T. MUNMSAPOLIB, MN WO
Proposed Garage noor nev. j e /.3'
r
REVIEWED FOR
16 �= / CODE COMPLIANCE
0
Z 6 '49" =-
&A ' •�
EAGAN
� .�L•=.:r' Derek Quelle
� 06!30/20231:39:20 PM
BUILDING INSPECTIONS
�+• . o �i Installing a 21'x 13'
j3x21k . deck with stairs.
� 9� EA183112
Property line must
I "LRXNV C=I."PV Tw►T TMs AMM a A TIMI A* comm -1 T or be verified and
staked with string
c do o,'�s line in this area for
footing inspection
Lot 4.111ock Z.Brittany 8tb. Addition,
'Dakota County.Wonesota.
r \
As GURV9V:o BY Ms TNI Zad. s•T of Deco AAL 1483_..._
P. Q JACHWN. MIM A RE-IarRATim1. Na. aeon
Required Information for Deck Permits Site Address: 4867 Knottingham Cir, Eagan, MN 55122
Ledgerloks
Simpson DDT1Z
LPC6 2 per post
LUS28-TZ
Type of hardware to be used:
Two (2) copies of plans that Include:
Ledger board:
Permit EA183112
❑
Dimensions of deck:
13'X21'
❑
Height of deck from ground: 9'
❑
Size of posts:
6"X6"
❑
Spacing of posts:
7'
❑
Footing diameter:
12" belled to 17"
❑
Footing depth:
48"
0
If sizes vary, leave blank and indicate individual sizes on plans.
*42" minimum for traditional
concrete footing. Specify if using engineered footings
Joist to beam:
❑
Joist hanger
(i.e., Diamond Pier) and provide installation instructions.
❑
Size of beam(s):
3-2"X10"
❑
Drop or flush beam(s):
Flush
Distance to property lines
*Example: 2 - 2" x 12"
❑
Cantilever on beam(s):
Q"
❑
Size of joists:
2"X10"
❑
Spacing of joists:
16"O.C.
❑
Species of lumber for framing:
Southern Pine
❑
Dimensions of floorboards:
1 "X6"
❑
Floorboard type:
Moistrue Shield - Elevate - Riverbank
❑
Pattern of floorboards:
*i.e: perpendicular (90 degrees) to joists, 30/45/or 60 degrees to joists
❑
Stair width:
48"
❑
Stair stringer spacing:
8" O.C.
❑
Stair length:
137
❑
Will the deck be built around a cantllevered area? (i.e., a bay with a patio door)
Yes Lia
MUM
❑
What type of floor framing will the ledger be attached to? (i.e., 1 -joist, floor truss, 2"x 10", etc.)
2X10
Distance to property lines:
❑
Side 1:
10.5'
❑
Rear:
25'
❑
Side 2:
80"
❑
Other:
Ledgerloks
Simpson DDT1Z
LPC6 2 per post
LUS28-TZ
Type of hardware to be used:
Two (2) copies of plans that Include:
Ledger board:
❑
Ledger board connection:
CODE COMPLIANCE
❑
Lateral load connection:
CL
Beam to posts:
ElPlan
❑
Post cap (manufacturer/model)
❑
Through bolts (size)
m
❑
Other approved type
0
Nmk Oude
IL
Applicable supplemental information
Joist to beam:
❑
Joist hanger
BUILDING INSPECTIONS
❑
Other
❑
❑
Any other hardware used:
Ledgerloks
Simpson DDT1Z
LPC6 2 per post
LUS28-TZ
Final Checklist for Permit Submittal
Two (2) copies of plans that Include:
REVIEWED FOR
CODE COMPLIANCE
❑
Cross section view
ElPlan
view
01-M-1
❑
Stair framing view
EAGAN
Nmk Oude
❑
Applicable supplemental information
Of3912M 1213:19 PM
BUILDING INSPECTIONS
Site plan, drawn to scale on survey or plat map, including:
❑
Deck dimensions
❑
Distance to property lines