Loading...
EA182980 - Building - Deck - Issued Date 07/14/2023PERMIT City of Eagan ®® Permit Type: Building 3830 Pilot Knob Rd Eagan, MN 55122 ®0®a® ®®®®°® m®®® ®®-®E AU A N Permit Number: EA182980 (651) 675-5675 111111111111 www.cityofeagan.com * E R 1 8 2 9 8 0 Date Issued: 7/14/2023 Site Address: 4443 Woodgate Ct Lot: 005 Block: 003 Addition: Woodgate 3rd PID:10-84602-03-050 Use: * 1 0— 8 4 6 0 2— 0 3— 0 S 0 Description: Sub Type: Deck Construction Type: V -B Work Type: Alteration Description: extension of corner of deck Census Code: 434 - Residential Additions, Alterations Occupancy: IRC -3 Zoning: PD Square Feet: 0 Comments: Fee Summary: (BL) Plan Review $97.31 0720.4222 Valuation: 5,600.00 BL - Base Fee $149.70 0801.4085 Surcharge - Based on Valuation $3.00 9001.2195 Total: $250.01 Contractor: Owner: - Applicant - Brian & Kelly Schultz 4443 Woodgate Ct Eagan MN 55122-242 This permit shall be null and void if work does not start within 180 days of issuance, or if work is suspended for 180 days or more after started. I hereby acknowledge that I have read this application and state that the information is correct and agree to comply with all applicable State of Minnesota Statutes and City of Eagan Ordinances. Applicant/Permitee: Signature ssued B . Signature EC IVE MAY 1 ? 2023 , 8Y: � •e e ,• ,` '• I e I' V I �1 q1 I 3830 PILOT MOB ROAD I EAGAN, MN 55122-1810 (651) 675-56751 FAX (651) 575-5594 buikflnainspectionsgDctvofeanan.com r ---------------------I I For Office use C I I Building Permit it ya (� I I I I I S&W Permit #. I x,50,01 Permit Fee: I I I I Date Received. I I I I Date Issued: ---------------------I RESIDENTIAL BUILDING PERMIT APPLICATION 5/15/2023 4443 Woodgate Ct Date: site AWS: Unita: Applicant is: 0 Owner ❑ Contractor Brian and Kelly Schultz Name: Address: 4443 Woodgate Ct Ctiy. Eagan Homeowner MN 55122 6512632870 Brianschultz1 @gmail.com State: Zip: Phone: Email: Description of work Extension of comer of deck T pe f Construction Cost: —2,000 V p) Woo 9q Type of building: ❑ Single Family 0 Towmhome, of units ❑ Twin Home Company: Contact Building Address: City: Contractor State: Trp: Phone: Email: License # iration Date: Sewer & Company: Contact Water Contractor Address: City: Required for State: Zip: Phone: Email: now construction License # iration Date: 0 1 understand that Plumbing, Mechanical, and Fire Suppression work require separate applications. NOTE: Plants and supporting documents that you submit are considered to be public information. Portions of the Information may be classified as non-public if you provide specific reasons that mould permit the City to conclude that they are trade secrets. CALL BEFORE YOU DIG. Contact Gopher State One Call at (651) 454-0002 or www.gioaherstateoneral .om for protection against underground utility nage. Gbntact Gopher State One Call 48 hours before you intend to dig to receive Dates of underground utilities. i hereby acknowledge that this information is complete and accurate; that the work will be in conformance with the ordinances and codes of the City of Eagan; that 1 understand this is not a permit, but only an application for a permit, and work is not to start without a permit; that the work will be in accordance with the approved plan in the case of work which requires a review and approval of plans. X Brian Schultz —R -A?-i(',4-4A 5�� rx Applicant's Printed Name App icanis Signature SUB TYPES Single Family _ 01 of Plex Deck WORK TYPES _ New Addition _✓Alteration Replace FOR OFFICE USE ONLY Site Address: 4443 Woodgate Ct _ Fireplace Foundation _ Garage _ Repair _ Fire Repair _ Water Damage Egress Window Calculated Valuation $ 5,600 Plan Review 025% 01008/6 Census Code # of Units # of Buildings _ Type of Construction VB _ Lower Levey Porch — Pool _ Siding _ Reroof _ Windows _ Solar Occupancy I RC 3 Code Edition 2020 M N RC Zoning PD Permit #: idougii _ Retaining Wall _ Move Building — Demolish Building* .Demolition of entire building — give PCA. handout to applicant MCES System SAC Units City Water Stories Booster Pump Square Feet PRV Fire Suppression Required Separate Stoimwater Management Permit Required REQUIRED INSPECTIONS Footings: New Addition ✓ Deck Foundation: Before Backfill Poured Wall ✓ Framing: 1 Hour �ZResldentlal Alteration Braced Wall FramingBlocking Braced Wall Sheathing (prior to house wrap) Interior Braced Wall Panel(s) REVIEWED FOR Firewalls CODE COMPLIANCE Insulation Radon Control Drain Tile Grading v"!, .. EAGAN Derek Qualle 05128!202310:24:01 AM Meter Size: Siding: _Stucco Lath _Stone Lath Brick Roof: _Ice & Water _Final Erosion Control Pool: _Footings Air/Gas Tests _Final Retaining Wali: _Footings _Backfill _Final Fire Suppression: _Rough In _Final Windows Other. Final/No C.O. Required FinaUC.O. Required Reviewed By: Building Inspector PEES^ Calculated Valuation $ 5,600 Adding 7x8 deck section to existing deck for a total area of 14x20= 280sf. Re decking deck Base Fee $ 149.70 with Cedar decking and replacing guardrails. Plan Review $ 97.31 State Surcharge $ 3.00 Met Council SAC — 280sf x $20 = $5,600 City SAC Treatment Plant — Water Supply & Storage S&W Permit & Surcharge — Meter Radio Read Other: $ 250.01 Address must be posted during construction. 4443 Woodgate Ct Required Information for Deck Permits Site Address: Distance to property lines: [ff Side 1: rs ❑ Side 2: Type of hardware to be used: Ledger board: ❑ Ledger board connection: I [3 Lateral load connection: Beam to posts: ro ❑ Post cap (manufacturer/model) ❑ Through bolts (size) ❑ Other approved type a. Joist to beam: ❑ Joist hanger ❑ Other 0 Any other hardware used: `l N ❑ Rear. 3 S It ,I Other. Simpson DTfZ1 Post cap connectors single hangers at beam with 3' handdrive nails in through the sides, 1 1/2" hanger nails on face. hurricane clips j v °d � 1,✓� 11 � �\ Adjusted per conversation with contractor Final Checklist for Permit Submittal Two 2 copies of plans that Include: REVIEWED FOR ( ) P PI CODE COMPUANC ❑ Cross section view , ❑ Plan view -- EAGAN ❑ Applicable supplemental Information°"'4M=831:MAM BURRING INSPECTIO Site plan, drawn to scale on survey or plat map, Including: ❑ Deck dimensions ❑ Distance to property lines EA 182980 ® Dimensions of deck: 77 by 8'0" extension ® Height of deck from ground: 8' 6" ® Size of posts: 6X6 ® Spacing of posts: 514" B Footing diameter. 14" ❑ Footing depth: 'If sizes vary, leave blank and indicate Individual sizes on plans. '42' minimum for traditional concrete footing. Specify If using engineered footings (I.s., Diamond Pier) and provide Installation instructions. ® size of beam(s): (2)2 x 10 ❑ Drop or flush beam(s): Flush and Drop `Example: 2 - 2"x 12° ❑ Cantilever on beam(e): 10" o ® Size of joists: 2x10 ® Spacing of joists: 16" ❑ Species of lumber for framing: Southern Pine #2 B Dimensions of floorboards: ? regular cedar dock boards ® Floorboard type: cedar decking ® Pattern of floorboards: parallel to house *I.e: perpendicular (80 degrees) to joists, 30/45/or 60 degrees to joists ❑ Stair width: ❑ Stair stringer spacing: ❑ Stair length: ❑ Will the deck be built around a cantilevered area? (i.e., a bay with a patio door) Yes / o ❑ What type of floor framing will the ledger be attached to? (i.e., Ijolst, floor truss, 2"x 10°, etc.) Distance to property lines: [ff Side 1: rs ❑ Side 2: Type of hardware to be used: Ledger board: ❑ Ledger board connection: I [3 Lateral load connection: Beam to posts: ro ❑ Post cap (manufacturer/model) ❑ Through bolts (size) ❑ Other approved type a. Joist to beam: ❑ Joist hanger ❑ Other 0 Any other hardware used: `l N ❑ Rear. 3 S It ,I Other. Simpson DTfZ1 Post cap connectors single hangers at beam with 3' handdrive nails in through the sides, 1 1/2" hanger nails on face. hurricane clips j v °d � 1,✓� 11 � �\ Adjusted per conversation with contractor Final Checklist for Permit Submittal Two 2 copies of plans that Include: REVIEWED FOR ( ) P PI CODE COMPUANC ❑ Cross section view , ❑ Plan view -- EAGAN ❑ Applicable supplemental Information°"'4M=831:MAM BURRING INSPECTIO Site plan, drawn to scale on survey or plat map, Including: ❑ Deck dimensions ❑ Distance to property lines EA 182980