EA182980 - Building - Deck - Issued Date 07/14/2023PERMIT
City of Eagan
®®
Permit Type:
Building
3830 Pilot Knob Rd
Eagan, MN 55122
®0®a® ®®®®°®
m®®® ®®-®E AU A N
Permit Number:
EA182980
(651) 675-5675
111111111111
www.cityofeagan.com
* E R 1 8 2 9 8
0
Date Issued:
7/14/2023
Site Address: 4443
Woodgate Ct
Lot: 005 Block: 003
Addition: Woodgate 3rd
PID:10-84602-03-050
Use:
* 1 0— 8 4 6 0 2— 0 3— 0 S 0
Description:
Sub Type: Deck
Construction Type:
V -B
Work Type: Alteration
Description: extension of corner of deck
Census Code: 434 - Residential Additions, Alterations Occupancy:
IRC -3
Zoning: PD
Square Feet: 0
Comments:
Fee Summary:
(BL) Plan Review $97.31
0720.4222
Valuation: 5,600.00
BL - Base Fee $149.70
0801.4085
Surcharge - Based on Valuation $3.00
9001.2195
Total: $250.01
Contractor:
Owner: - Applicant -
Brian & Kelly Schultz
4443 Woodgate Ct
Eagan MN 55122-242
This permit shall be null and void if work does not start within 180 days of issuance, or if work is suspended for 180 days or more after
started.
I hereby acknowledge that I have read this application and state that the information is correct and agree to comply with all applicable State
of Minnesota Statutes and City of Eagan Ordinances.
Applicant/Permitee: Signature
ssued B . Signature
EC IVE
MAY 1 ? 2023 ,
8Y:
� •e e
,• ,` '• I e I' V I
�1
q1 I
3830 PILOT MOB ROAD I EAGAN, MN 55122-1810
(651) 675-56751 FAX (651) 575-5594
buikflnainspectionsgDctvofeanan.com
r ---------------------I
I For Office use C I
I Building Permit it ya (� I
I I
I I
S&W Permit #. I
x,50,01
Permit Fee: I
I I
I Date Received. I
I I
I Date Issued:
---------------------I
RESIDENTIAL BUILDING PERMIT APPLICATION
5/15/2023 4443 Woodgate Ct
Date: site AWS: Unita:
Applicant is: 0 Owner ❑ Contractor
Brian and Kelly Schultz
Name:
Address: 4443 Woodgate Ct Ctiy. Eagan
Homeowner
MN 55122 6512632870 Brianschultz1 @gmail.com
State: Zip: Phone: Email:
Description of work Extension of comer of deck
T pe f
Construction Cost: —2,000 V p) Woo 9q
Type of building: ❑ Single Family 0 Towmhome, of units ❑ Twin Home
Company: Contact
Building
Address: City:
Contractor
State: Trp: Phone: Email:
License # iration Date:
Sewer &
Company: Contact
Water
Contractor
Address: City:
Required for
State: Zip: Phone: Email:
now construction
License # iration Date:
0 1 understand that Plumbing, Mechanical, and Fire Suppression work require separate applications.
NOTE: Plants and supporting documents that you submit are considered to be public information. Portions of the
Information may be classified as non-public if you provide specific reasons that mould permit the City to conclude that they
are trade secrets.
CALL BEFORE YOU DIG. Contact Gopher State One Call at (651) 454-0002 or www.gioaherstateoneral .om for protection against underground utility
nage. Gbntact Gopher State One Call 48 hours before you intend to dig to receive Dates of underground utilities.
i hereby acknowledge that this information is complete and accurate; that the work will be in conformance with the ordinances and codes of the City of
Eagan; that 1 understand this is not a permit, but only an application for a permit, and work is not to start without a permit; that the work will be in
accordance with the approved plan in the case of work which requires a review and approval of plans.
X Brian Schultz —R -A?-i(',4-4A 5�� rx
Applicant's Printed Name App icanis Signature
SUB TYPES
Single Family
_ 01 of Plex
Deck
WORK TYPES
_ New
Addition
_✓Alteration
Replace
FOR OFFICE USE ONLY
Site Address: 4443 Woodgate Ct
_ Fireplace
Foundation
_ Garage
_ Repair
_ Fire Repair
_ Water Damage
Egress Window
Calculated Valuation $ 5,600
Plan Review 025% 01008/6
Census Code
# of Units
# of Buildings _
Type of Construction VB
_ Lower Levey
Porch
— Pool
_ Siding
_ Reroof
_ Windows
_ Solar
Occupancy I RC 3
Code Edition 2020 M N RC
Zoning PD
Permit #: idougii
_ Retaining Wall
_ Move Building
— Demolish Building*
.Demolition of entire building — give PCA.
handout to applicant
MCES System
SAC Units
City Water
Stories Booster Pump
Square Feet PRV
Fire Suppression Required
Separate Stoimwater Management Permit Required
REQUIRED INSPECTIONS
Footings: New Addition ✓ Deck
Foundation: Before Backfill Poured Wall
✓ Framing: 1 Hour �ZResldentlal Alteration
Braced Wall FramingBlocking
Braced Wall Sheathing (prior to house wrap)
Interior Braced Wall Panel(s) REVIEWED FOR
Firewalls CODE COMPLIANCE
Insulation
Radon Control
Drain Tile
Grading
v"!,
..
EAGAN
Derek Qualle
05128!202310:24:01 AM
Meter Size:
Siding: _Stucco Lath _Stone Lath Brick
Roof: _Ice & Water _Final
Erosion Control
Pool: _Footings Air/Gas Tests _Final
Retaining Wali: _Footings _Backfill _Final
Fire Suppression: _Rough In _Final
Windows
Other.
Final/No C.O. Required
FinaUC.O. Required
Reviewed By: Building Inspector
PEES^
Calculated Valuation $ 5,600
Adding 7x8 deck section to existing deck for a
total area of 14x20= 280sf. Re decking deck
Base Fee
$ 149.70
with Cedar decking and replacing guardrails.
Plan Review
$ 97.31
State Surcharge
$ 3.00
Met Council SAC
—
280sf x $20 = $5,600
City SAC
Treatment Plant
—
Water Supply & Storage
S&W Permit & Surcharge
—
Meter
Radio Read
Other:
$ 250.01
Address must be posted during construction. 4443 Woodgate Ct
Required Information for Deck Permits Site Address:
Distance to property lines:
[ff Side 1:
rs ❑ Side 2:
Type of hardware to be used:
Ledger board:
❑ Ledger board connection:
I [3 Lateral load connection:
Beam to posts:
ro
❑ Post cap (manufacturer/model)
❑ Through bolts (size)
❑ Other approved type
a. Joist to beam:
❑ Joist hanger
❑ Other
0 Any other hardware used:
`l N ❑ Rear.
3 S It ,I Other.
Simpson DTfZ1
Post cap connectors
single hangers at beam with 3' handdrive nails
in through the sides, 1 1/2" hanger nails on face.
hurricane clips
j v °d � 1,✓� 11 � �\
Adjusted per conversation with contractor
Final Checklist for Permit Submittal
Two 2 copies of plans that Include: REVIEWED FOR
( ) P PI CODE COMPUANC
❑ Cross section view ,
❑ Plan view --
EAGAN
❑ Applicable supplemental Information°"'4M=831:MAM
BURRING INSPECTIO
Site plan, drawn to scale on survey or plat map, Including:
❑ Deck dimensions
❑ Distance to property lines EA 182980
®
Dimensions of deck: 77 by 8'0" extension
®
Height of deck from ground: 8' 6"
®
Size of posts: 6X6
®
Spacing of posts: 514"
B
Footing diameter. 14"
❑
Footing depth:
'If sizes vary, leave blank and indicate Individual sizes on plans.
'42' minimum for traditional concrete footing. Specify If using engineered footings
(I.s., Diamond Pier) and provide Installation instructions.
®
size of beam(s): (2)2 x 10
❑
Drop or flush beam(s): Flush and Drop
`Example: 2 - 2"x 12°
❑
Cantilever on beam(e): 10"
o
®
Size of joists: 2x10
®
Spacing of joists: 16"
❑
Species of lumber for framing: Southern Pine #2
B
Dimensions of floorboards: ? regular cedar dock boards
®
Floorboard type: cedar decking
®
Pattern of floorboards: parallel to house
*I.e: perpendicular (80 degrees) to joists, 30/45/or 60 degrees to joists
❑
Stair width:
❑
Stair stringer spacing:
❑
Stair length:
❑
Will the deck be built around a cantilevered area? (i.e., a bay with a patio door)
Yes / o
❑
What type of floor framing will the ledger be attached to? (i.e., Ijolst, floor truss, 2"x 10°, etc.)
Distance to property lines:
[ff Side 1:
rs ❑ Side 2:
Type of hardware to be used:
Ledger board:
❑ Ledger board connection:
I [3 Lateral load connection:
Beam to posts:
ro
❑ Post cap (manufacturer/model)
❑ Through bolts (size)
❑ Other approved type
a. Joist to beam:
❑ Joist hanger
❑ Other
0 Any other hardware used:
`l N ❑ Rear.
3 S It ,I Other.
Simpson DTfZ1
Post cap connectors
single hangers at beam with 3' handdrive nails
in through the sides, 1 1/2" hanger nails on face.
hurricane clips
j v °d � 1,✓� 11 � �\
Adjusted per conversation with contractor
Final Checklist for Permit Submittal
Two 2 copies of plans that Include: REVIEWED FOR
( ) P PI CODE COMPUANC
❑ Cross section view ,
❑ Plan view --
EAGAN
❑ Applicable supplemental Information°"'4M=831:MAM
BURRING INSPECTIO
Site plan, drawn to scale on survey or plat map, Including:
❑ Deck dimensions
❑ Distance to property lines EA 182980