Loading...
EA185051 - Building - Deck - Issued Date 07/18/20231W HIM% _III City of Eagan®m EAGAN Permit Type: Building 3830 Pilot Knob Rd ,me; a ®® Permit Number: EA185051 Eagan, MN 55122 ®® ®®®® (651) 675-5675 1111111111111111111111111111111111111111111111111 www.cityofeagan.com * E R 1 8 S 0 S 1* Date Issued: 7/18/2023 Site Address: 1032 Kettle Creek Rd Lot: 11 Block: 3 Addition: Lexington Square PID:10-45075-03-110 Use: * 10-4S07S-03-1 10* Description: Sub Type: Deck Construction Type: V -B Work Type: New Description: Census Code: 434 - Residential Additions, Alterations Occupancy: IRC -1 Zoning: PD Square Feet: 0 Comments: Fee Summary: (BL) Plan Review $75.79 0720.4222 BL - Base Fee Valuation: 3,920.00 $116.60 0801.4085 Surcharge - Based on Valuation $2.00 9001.2195 Total: $194.39 Contractor: Owner: Abraham Tesfai 1032 Kettle Creek Rd Saint Paul MN 55123-451 - Applicant - This permit shall be null and void if work does not start within 180 days of issuance, or if work is suspended for 180 days or more after started. I hereby acknowledge that I have read this application and state that the information is correct and agree to comply with all applicable State of Minnesota Statutes and City of Eagan Ordinances. Applicant/Petmitee: Signature ssued B : Signature E AG •�•• ••.• �1 3830 PILOT KNOB ROAD I EAGAN, MN 55122-1E (651) 675-5675 1 FAX: (651) 675-5694 buildinoinsaectionsC&-citvofealaan.com �l4 t---------------------� I For Office Use i I I Building Permit #: 7 !G® G I I I S&W Permit #: I I lq I Permit Fee: I I I I i Date Received: I I I I I I Date Issued: I ---------------------J RESIDENTIAL BUILDING PERMIT APPLICATION Date: Site Address: Unit #: Applicant is: 14 Owner ❑ Contractor 11 h 0 (neo W m Name: Homeowner Address: �� � 2 City: 1 In State: Zip: 3 Phone Email: ° Description of work:°`-C.��� L.ona/C-SVy.. Type of Work Construction Cost: pPJC (vi� { -0 `�'�1VO R� '�1 Type of building: Single Family ❑ Townhome, of units ❑ Twin Home Company: [� A & 1A f L I& E� Contact: T-- L ( Building Address: MW City: Q V I L L Contractor State: �Z1p:�� f Pho 0 � 3,x-28—k—b il: S & Lt ( t�`(IL� AA l �"IeL —Expiration License #: Date: �3 Sewer $ Company: Contact: Water Contractor Address: City: Required for tate: Zip: Phone: Email: new construction License #: Expiration Date: 14 1 understand that Plumbing, Mechanical, and Fire Suppression work require separate applications. NOTE: Plans and supporting documents that you submit are considered to be public Information. Portions of the Information may be classified as non-public If you provide specific reasons that would permit the City to conclude that they are trade secrets. CALL BEFORE YOU DIG. Contact Gopher State One Call at (651) 454-0002 or www.000herstateonecall.oro for protection against underground utility damage. Contact Gopher State One Call 48 hours before you intend to dig to receive locates of underground utilities. I hereby acknowledge that this information is complete and accurate; that the work will be in conformance with the ordinances and codes of the City Eagan; that I understand this is not a permit, but only an application for a permit, and work is not to start without a permit; that the work will be accordance with the approved plan in the case of work which requires a review and approval of plans. Applicant's Printed Name AhApplicant's Sign tures �WA� -f Required Information for Deck Permits Site Address: Dimensions of deck: Height of deck from ground: Size of posts: X Spacing of posts: r 91A Footin lameter: 1S- a [� Footing depth: `tom *If sizes vary, ave blank and indicate individual sizes on plans. *42" minimum for traditional concrete footing. Specify if using engineered footings (i.e., Diamond Pier) and provide installation instructions. Size of beam(s): Ini Drop or flush beam(s): �. *Example: 2 - 2" x 12' N a9 Cantilever on beam(s): c Size of joists: X uo ( Spacing of joists: l �j ��AL Species of lumber for framing: c ElDimensions of floorboards: M Floorboard type: j Pattern of floorboards: *i.e: perpendicular (90 degrees) to joists, 30/4 or 60 degrees to joists Stair width: /�� f) Stair stringer spacing: t ® Lt Stair length: Will the deck be built around a cantilevered area? (i.e., a bay v✓ith a patio door) Yes / No I W ®' What type of floor framing will the ledger be attached to? (i.e., I joist, floor truss, 2" x 10", etc.) m N Distance to property lines: Side 1: ) a ❑ Rear: N Side 2: ,!� 4 �, Other:�� c Type of hardware to be used: Ledger board: Ledger board connection:�- a Lateral load connection: Final Checklist for Permit Submittal W Beam to posts: Two (2) copies of plans that include: rPost oap (manufacturer/modely l C ,, _) Cross section view m ❑ TKrough bolts (size) ❑ Plan view c Other a e roved ❑ pp type ❑ Stair framing view CL` Joist to beam: ❑ Applicable supplemental information Joist hanger S l,1oLQ I ' L&ASite plan, drawn to scale on survey or plat map, including: ❑ Other ❑ Deck dimensions ❑ Any other hardware used: ❑ Distance to property lines SUB TYPES Single Family _ 01 of _ Plex Deck WORK TYPES IeL—New Addition _ Alteration Replace FOR OFFICE USE ONLY Site Address: 1 Q �%— J!�(?M f, NQf k RV Permit #: J ) 5®G 1 Fireplace _ Foundation Garage _ Repair Fire Repair Water Damage _ Egress Window Calculated Valuation 3, Vo Plan Review 025% X00% Census Code # of Units # of Buildings Type of Construction V►3 Lower Level Porch Pool _ Siding Reroof Windows Solar _ Retaining Wall Move Building Demolish Building* 'Demolition of entire building — give PCA handout to applicant Occupancy 3y c_ I MCES System Code Edition /`�' jP-r--,2b SAC Units Zoning City Water Stories Booster Pump Square Feet PRV Fire Suppression Required Separate Stormwater Management Permit Required REQUIRED INSPECTIONS Footings: New Addition r-�- Deck Foundation: Before Backfill Poured Wall ,C Framing: 1 Hour residential Alteration Braced Wall Framing/Blocking Braced Wall Sheathing (prior to house wrap) Interior Braced Wall Panel(s) Firewalls Insulation Radon Control Drain Tile Grading Meter Size: Siding: _Stucco Lath _Stone Lath _Brick Roof: _Ice & Water _Final Erosion Control Pool: _Footings Air/Gas Tests _Final Retaining Wali: _Footings _Backfill _Final Fire Suppression: _Rough In _Final Windows Other: Final/No C.O. Required Final/C.O. Required Reviewed By: Building Inspector FEES Calculated Valuation �,9� )y x IY� Base Fee GJ�S-�+=•rs -6 e...�` Plan Review State Surcharge Met Council SAC City SAC Treatment Plant Water Supply & Storage S&W Permit & Surcharge Meter Radio Read Other: TOTAL $ 0.00 Required Information for Deck Permits Site address: 1032 Kettle Creek Rd � 1 Dimensions of deck: rif Size of posts: K b Footing diameter: 14" P4 "If sizes vary, leave blank and indicate individual sizes on plans. Size of beam(s): "Example: 2 — 2" x 12" 1A C cantilever on beam(s): CL C 0 Size of joists: Species of lumber for framing: C ❑ Dimensions of floorboards: .9- - '�9- " X tp M K Height of deck from ground: d Spacing of posts: r 9 " Footing depth: y '42" minimum for traditional concrete footing. Specify if using engineered footings (i.e., Diamond Pier) and provide installation instructions. Drop or flush beam(s): �. %A See note on plans X W Spacing of joists: 'C7-4_�01 dao Floorboard type: 19 Pattern of floorboards:pgyb lo -e �.- d� kw ` 'i.e: perpendicular (90 degrees) to joists, 30/4 or 60 degrees to joists J Stair width: Stair length: See UltraDeck installation requirement handout 12" -��... attached to plans 0 0,40,.,&'f UltraDeck Fusion ►I �t See UltraDeck installation requirement L1,42M Stair stringer spacing: 8 1,& handout attached to plans Will the deck be built around a cantilevered area? (i.e., a bay with a patio door) What type of floor framing will the ledger be attached to? (i.e., 1 -joist, floor truss, 2"x 10", etc.) Yes/ No t /� Aof k W v e Distance to property lines: Wm Side 1: t 14- - ❑ Rear. Side 2:0 Other: �09 c Type of hardware to be used: Ledger board: R0 See Ledgerl-OK technical bulletin for [� Ledger board connection: n/ �L jtL-.a7TQ installation requirements (attached to plans) Lateral load connection: see DmZ technical bulletin for example of required later Final Checklist for Permit Submittal load connection. If using other brand of fastener, have Beam to posts: p Installation guide available to inspector at inspection. Two (2) copies of plans that include: REVIEWED FOR 9 ' � Post cap (manufacturer/model) Cross section view V L CODE COMPLANCE ❑ Through bolts (size) _ NOTE: PB44-6TZ required to ❑ Plan view -- c ❑ Other approved type be used in pairs (2 per post) ❑ Stair framing view EAGAN �� a` Joist to beam: ❑ Applicable supplemental information 07114rAM12:492D PAA Joist hanger S idall BUILDING INSPECTIONS �' '&T— -Z' C&► Site plan, drawn to scale on survey or plat map, including: ❑ Other Qp„e- ❑ Deck dimensions ❑ Any other hardware used: ❑ Distance to property lines