EA186164 - Building - Deck - Issued Date 10/02/2023 PERMIT
City of Eagan , + , Permit Type: Building
3830 Pilot Knob Rd °®w;0 a,p Permit Number: EA186164
Eagan,MN 55122 EAGAN
(651)675-5675 1111111111111
www.cityofeagan.com * E R 1 8 6 1 6 4
Date Issued: 10/2/2023
Site Address: 1712 Hickory Hill
Lot: 014 Block: 002 Addition: Woodgate 2nd
PID:10-84601-02-140
Use: * 10 - 8460 1 - 02 14 D *
Description:
Sub Type: Deck Construction Type: V-B
Work Type: Replace
Description: replacing deck boards and rails
Census Code: 434-Residential Additions,Alterations Occupancy: IRC-3
Zoning: PD
Square Feet: 0
Comments:
Fee Summary: (BL)Plan Review $54.28 0720.4222
BL-Base Fee $83.50 0801.4085
Valuation: 2,000.00 Surcharge-Based on Valuation $1.00 9001.2195
Total: $138.78
Contractor: - Applicant - Owner:
Apex Outdoor Inc Dominique Dabu
8608 Eagle Creek Circle 1704 Hickory Hill Dr
Savage MN 55378 Eagan MN 55122
(612)998-1905
This permit shall be null and void if work does not start within 180 days of issuance, or if work is suspended for 180 days or more after
started.
I hereby acknowledge that I have read this application and state that the information is correct and agree to comply with all applicable State
of Minnesota Statutes and City of Eagan Ordinances.
Applicant/Permitee: Signature Issued By: Signature
--------------
rFor Office Use
I 186164
Building Permit#:
I I
s�®p j S&W Permit#:
E A
A N
Permit Fee: IJ .19) I
�
Pill
Date Received: 8/18/2023
3830 PILOT KNOB ROAD I EAGAN, MN 55122-1810 I
(651)675-56751 FAX: (651)675-5694 ` I Date Issued: j
buildinginspections o)cityofeagan.com I—————————————————————
RESIDENTIAL BUILDING PERMIT APPLICATION
Date: 07.14.23 Site Address: 1712 hickory 101 Unit#:
Applicant is: ❑ Owner m Contractor
Name: Olson Property Management
Homeowner Address: City:1712 Hickory Lane EAGAN
State: mn Zi 55122 phone: NA NA
Email:
Description of work: replacing deck boars and rails
Typo of
Work ' Construction Cost: 6800
Type of building: ❑ Single Family ❑ Townhome, of units ❑ Twin Home
Company: APEX CONSTRUCTION Contact: KENT FIEBELKORN
Building Address: 8608 eagle creek circle City, savage
Cantractar, mn 55378 612.998.19C6 kent@apexconstructiommn.com
State: Zip: Phone: Email:
License#: BC755391 03.01.2025
Ex iration Date:
Sewer & Company: Contact:
UVater.
Onti"aCtdr` '{;, Address: City:
Required for State: Zip: Phone: Email:
new,construction '!
License#: Expiration Date:
® 1 understand that Plumbing, Mechanical, and Fire Suppression work require separate applications.
NOTE: Plans and supporting documents that you submit are considered to be public information. Portions of the
information 4 be classified ae non-public If you provide,specific reasons that would permit the City to conclude that they
are trade secrete.
CALL BEFORE YOU DIG. Contact Gopher State One Call at(651)454-0002 or www.gor)herstateonecall.org for protection against underground utility
damage. Contact Gopher State One Call 48 hours before you intend to dig to receive locates of underground utilities.
I hereby acknowledge that this information is complete and accurate;that the work will be in conformance with the ordinances and codes of the City of
Eagan; that I understand this is not a permit, but only an application for a permit, and work is not to start without a permit; that the work will be in
accordance with the approved plan in the case of work which requires a review and apr✓o/va of plans.
kent fiebelkorn 11, _t,`
x x
Applicant's Printed Name Applicant's Signature
FOR 0FF10E'USE ONLY
Site Address: 1712 Hickory Hill Permit#: EA186164
SUB TYPES
Single Family _ Fireplace _ Lower Level
_ 01 of_Plex _ Foundation _ Porch
✓ Deck _ Garage _ Pool
WORK TYPES
New _ Repair _ Siding _ Retaining Wall
Addition _ Fire Repair _ Reroof _ Move Building
✓ Alteration _ Water Damage _ Windows _ Demolish Building*
Replace Egress Window _ Solar •Demolition of entire building-give PCA
handout to applicant
DESCRIPTION
Calculated Valuation $2,000.00 Occupancy IRC-3 MCES System
Plan Review 025% 0100% Code Edition 202OMNRC SAC Units
Census Code Zoning PD City Water
#of Units Stories Booster Pump
#of Buildings Square Feet PRV
Type of Construction VB Fire Suppression Required
Separate Stormwater Management Permit Required
REQUIRED INSPECTIONS
Footings: New Addition Deck Meter Size:
Foundation: Before Backfill Poured Wall Siding:_Stucco Lath _Stone Lath _Brick
Framing: 1 Hour Residential Alteration Roof:_Ice&Water _Final
Braced Wall Framing/Blocking Erosion Control
Braced Wall Sheathing(prior to house wrap) Pool:_Footings —Air/Gas Tests _Final
Interior Braced Wall Panel(s) Retaining Wall:_Footings_Backfill_Final
Firewalls REVIEWED FOR Fire Suppression:_Rough In_Final
Insulation CODE COMPLIANCE Windows
Radon Control Other:
Drain Tile
Grading EAGAN ✓ Final/No C.O. Required
Derek Qualle Final/C.O. Required
08/22/2023 3:06:31 PM
Reviewed By: BUILDING INSPECTIONS r Building Inspector
FEES
Calculated Valuation $2,000.00 Redecking and replacing
Base Fee $83.50 guardrails on Deck
Plan Review $54.28
State Surcharge $1.00
Met Council SAC 1 0x8 = 80sf
City SAC
Treatment Plant
Water Supply S Storage 1 Inspection
SSW Permit SSurcharge Min valuation $2,000
Meter
Radio Read
Other:
TOTAL $ 138.78