Loading...
Deck JANUARY 22, 2018 STANDARD DETAIL FOR ALLOWING A DECK M11-DECK LEDGR LEDGER CONNECTION TO A FLOOR TRUSS �0 ® MiTek USA,Inc. Page 1 of 1 aaaa O 00 O OD a MiTek USA,Inc. ENGINES_ AED BV_0 A MiTek Affiliate LADDER TRUSS WITH 4X2 SPF NO.2 MINIMUM CHORD LUMBER,WEBS SHALL BE 4X4 STUD HF,SPF,DF OR SP AT 2x4 BAND 16"O.C.MAX. FASTENER(S)SPECIFIED DOUBLE END BY OTHERS VERTICAL FLOOR BLOCKING PER BUILDING DESIGNER FASTENER(S)SPECIFIED LEDGER SPECIFIED BY OTHERS. p BYO HERS � G LEDGER SPECIFIED BYOTHERS FLOOR TRUSSES 24"O.C.MAX. TYPICAL FLOOR TRUSS LADDER FRAME TO BE CONTINUOUSLY SUPPORTED BEARING AT END OF TRUSS FLOOR TRUSS PERPENDICULAR FLOOR TRUSS PARALLEL TO BEARING WALL TO BEARING WALL N.T.S. N.T.S. OTHER FRAMING ELEMENTS OTHER FRAMING ELEMENTS NOT SHOWN FOR CLARITY NOT SHOWN FOR CLARITY NOTES: DETAIL PERMITS A MAXIMUM OF TWO 5/8"DIA.THRU BOLTS OR LAG SCREWS TO BE INSTALLED ALONG THE VERTICAL CENTER LINE AND INTO THE DOUBLE END VERTICAL OF FLOOR TRUSSES OR INTO THE 4X4 VERTICALS OF A LADDER TRUSS. FASTENERS SHALL NOT INTERFERE WITH ANY JOINTS OR CONNECTORS WITHIN THE FLOOR OR LADDER TRUSS AND BE INSTALLED PER NDS. CAPACITY OF CONNECTION SHALL BE SPECIFIED BY THE BUILDING DESIGNER. REFER TO NATIONAL,STATE,LOCAL BUILDING CODES OR STANDARD INDUSTRY DETAILS APPROVED BY THE BUILDING OFFICAL. DETAIL HAS CONSIDERED VERTICAL LOAD CAPACITY OF THE FASTENERS ONLY.ALL OTHER FRAMING ELEMENTS REQUIRED TO SUPPORT AND OR RESIST ANY OTHER LOADS AND OR FORCES SHALL BE THE RESPONSIBILITY OF OTHERS. DESIGN OF ALL DECK OR PORCH COMPONENTS SHALL BE BY OTHERS. REVIEWED FOR CODE COMPLIANCE New Home Permit EA 186149 , Deck ledger attachment engineering for future EAGAN deck 02/13Derek Qualle /2024 7:40:51 AM BUILDING INSPECTIONS Derek Qualle From: Joe Bockoven <joe@pricehomes.com> Sent: Monday, February 12, 2024 11:50 AM To: Derek Qualle Cc: Tim Naugle Subject: 654 whitham lane Attachments: Standard for Allowing Deck Ledger Connection to Floor Truss MII-DECK LEDGR.pdf Hi derek, Here are the charts SBCA Research Report(SRR) Truss Joist Span Connection Deck Connection Details <to 6' 6'-1"to 8' 8'-1"to 10' 10'-1"to 12' 12'-1"to 14' 14'-1"to 16' 16'-1"to 18' Condition Loading — On-center Spacing of Fasteners(in.)4 Live Load +/2"x 6"lag screw with =40 psf, 15/32",max.,wood 24 125 125 125 125 86 86 Dead Load structural sheathing =10 psf, Snow Load 1/2*diameter bolt with <40 psf 15132",max.,wood 24 24 24 24 24 125 125 End structural sheathing Connection + Live Load /j"x 6"lag screw Use bolted =60 psf, with 75132",max.,wood 125 121 121 86 81 86 connection Dead Load structural sheathing =10 psf, + " Snow Load /2 diameter bolt with <60 psf 15132",max.,wood 24 24 24 125 125 125 125 structural sheathing Live Load 1/2"x 6"lag screw =40 psf, with 45132",max.,wood 16 16 16 87 87 87 87 Dead Load structural sheathing =10 psf, + " Snow Load /z diameter bolt with <40 psf 15132",max.,wood 32 32 32 16 16 16 16 structural sheathing Side Connection1/2"x 6"lag screw Live Load Use bolted =60 psf, with t5/32",max.,wood 16 16 87 87 87 87 connection Dead Load structural sheathing =10 psf, Snow Load +/2"diameter bolt with <60 psf 15/32",max.,wood 32 32 16 16 16 87 87 structural sheathing 1.Ledgers shall be flashed in accordance with applicable building code requirements to prevent water from contacting the exposed wood structural sheathing and floor truss. 2.Snow bad shall not be assumed to act concurrently with live load. 3.Ledgers must be 2x10 or 202 PPT or code-approved decay-resistant lumber with specific gravity,G>0.43.Truss 2-ply 2x4 end verticals and key-blocks must have a G>OA2. 4.Stagger lag screws and bolts as shown in Detail 1 for End Connection and Detail 2 for Side Connection, 5.If trusses are spaced greater than 12'o.c.,install key blocks between the trusses to provide ledger attachment every 12".Attach ledger to 2-ply end vertical of each truss with one(1) fastener and to each key-block with one(1)fastener.Refer to DDetail 1 for key-block construction and installation information. 6.Install key blocks between the trusses,as required,to provide ledger attachment every 8'.Attach ledger to 2-ply end vertical of each truss with one(1)fastener and to each key-block with one(1)fastener.Refer to Det'. 'for key-block construction and installation information. 7.Install key blocks between the vertical webs of the floor ladder frame to provide ledger attachment every 8".Attach ledger to each 4x4 vertical web with one(1)fastener and to each key- block with one(1)fastener.Refer to[)eta:!2 for key-block construction and installation information. REVIEWED FOR CODE COMPLIANCE New Home Permit EA 186149 Deck ledger attachment _ engineering for future EAGAN e,e,oal,e t deck BUILDING INSPECTIONS **Please note m new email address** REVIEWED FOR Y CODE COMPLIANCE New Home Permit EA 186149 XJ Deck ledger attachment Joe BockovenEAGAN engineering for future Project Manager, Price Homes deck 011==1 A. 11110 Industrial Circle NW,Suite E,Elk River,MN 55330 BUILDING INSPECTIONS Office: 763-276-7197 Cell: 763-464-1851 Website: PriceHomes,com 3