Deck JANUARY 22, 2018 STANDARD DETAIL FOR ALLOWING A DECK M11-DECK LEDGR
LEDGER CONNECTION TO A FLOOR TRUSS
�0 ® MiTek USA,Inc. Page 1 of 1
aaaa
O 00
O OD
a
MiTek USA,Inc.
ENGINES_ AED BV_0
A MiTek Affiliate LADDER TRUSS WITH 4X2 SPF NO.2
MINIMUM CHORD LUMBER,WEBS SHALL
BE 4X4 STUD HF,SPF,DF OR SP AT
2x4 BAND 16"O.C.MAX.
FASTENER(S)SPECIFIED
DOUBLE END BY OTHERS
VERTICAL
FLOOR BLOCKING PER
BUILDING DESIGNER
FASTENER(S)SPECIFIED LEDGER
SPECIFIED
BY OTHERS. p BYO HERS
� G
LEDGER SPECIFIED
BYOTHERS FLOOR TRUSSES
24"O.C.MAX.
TYPICAL FLOOR
TRUSS LADDER FRAME TO BE
CONTINUOUSLY SUPPORTED
BEARING AT
END OF TRUSS
FLOOR TRUSS PERPENDICULAR FLOOR TRUSS PARALLEL
TO BEARING WALL TO BEARING WALL
N.T.S. N.T.S.
OTHER FRAMING ELEMENTS OTHER FRAMING ELEMENTS
NOT SHOWN FOR CLARITY NOT SHOWN FOR CLARITY
NOTES:
DETAIL PERMITS A MAXIMUM OF TWO 5/8"DIA.THRU BOLTS OR LAG SCREWS TO BE INSTALLED ALONG THE VERTICAL CENTER LINE AND
INTO THE DOUBLE END VERTICAL OF FLOOR TRUSSES OR INTO THE 4X4 VERTICALS OF A LADDER TRUSS.
FASTENERS SHALL NOT INTERFERE WITH ANY JOINTS OR CONNECTORS WITHIN THE FLOOR OR LADDER TRUSS AND BE INSTALLED
PER NDS.
CAPACITY OF CONNECTION SHALL BE SPECIFIED BY THE BUILDING DESIGNER. REFER TO NATIONAL,STATE,LOCAL BUILDING CODES
OR STANDARD INDUSTRY DETAILS APPROVED BY THE BUILDING OFFICAL.
DETAIL HAS CONSIDERED VERTICAL LOAD CAPACITY OF THE FASTENERS ONLY.ALL OTHER FRAMING ELEMENTS REQUIRED TO
SUPPORT AND OR RESIST ANY OTHER LOADS AND OR FORCES SHALL BE THE RESPONSIBILITY OF OTHERS.
DESIGN OF ALL DECK OR PORCH COMPONENTS SHALL BE BY OTHERS. REVIEWED FOR
CODE COMPLIANCE
New Home Permit EA 186149 ,
Deck ledger attachment
engineering for future EAGAN
deck 02/13Derek Qualle
/2024 7:40:51 AM
BUILDING INSPECTIONS
Derek Qualle
From: Joe Bockoven <joe@pricehomes.com>
Sent: Monday, February 12, 2024 11:50 AM
To: Derek Qualle
Cc: Tim Naugle
Subject: 654 whitham lane
Attachments: Standard for Allowing Deck Ledger Connection to Floor Truss MII-DECK LEDGR.pdf
Hi derek,
Here are the charts
SBCA Research Report(SRR)
Truss Joist Span
Connection Deck Connection Details <to 6' 6'-1"to 8' 8'-1"to 10' 10'-1"to 12' 12'-1"to 14' 14'-1"to 16' 16'-1"to 18'
Condition Loading —
On-center Spacing of Fasteners(in.)4
Live Load +/2"x 6"lag screw with
=40 psf, 15/32",max.,wood 24 125 125 125 125 86 86
Dead Load structural sheathing
=10 psf,
Snow Load 1/2*diameter bolt with
<40 psf 15132",max.,wood 24 24 24 24 24 125 125
End structural sheathing
Connection +
Live Load /j"x 6"lag screw Use bolted
=60 psf, with 75132",max.,wood 125 121 121 86 81 86 connection
Dead Load structural sheathing
=10 psf, + "
Snow Load /2 diameter bolt with
<60 psf 15132",max.,wood 24 24 24 125 125 125 125
structural sheathing
Live Load 1/2"x 6"lag screw
=40 psf, with 45132",max.,wood 16 16 16 87 87 87 87
Dead Load structural sheathing
=10 psf, + "
Snow Load /z diameter bolt with
<40 psf 15132",max.,wood 32 32 32 16 16 16 16
structural sheathing
Side
Connection1/2"x 6"lag screw
Live Load Use bolted
=60 psf, with t5/32",max.,wood 16 16 87 87 87 87 connection
Dead Load structural sheathing
=10 psf,
Snow Load +/2"diameter bolt with
<60 psf 15/32",max.,wood 32 32 16 16 16 87 87
structural sheathing
1.Ledgers shall be flashed in accordance with applicable building code requirements to prevent water from contacting the exposed wood structural sheathing and floor truss.
2.Snow bad shall not be assumed to act concurrently with live load.
3.Ledgers must be 2x10 or 202 PPT or code-approved decay-resistant lumber with specific gravity,G>0.43.Truss 2-ply 2x4 end verticals and key-blocks must have a G>OA2.
4.Stagger lag screws and bolts as shown in Detail 1 for End Connection and Detail 2 for Side Connection,
5.If trusses are spaced greater than 12'o.c.,install key blocks between the trusses to provide ledger attachment every 12".Attach ledger to 2-ply end vertical of each truss with one(1)
fastener and to each key-block with one(1)fastener.Refer to DDetail 1 for key-block construction and installation information.
6.Install key blocks between the trusses,as required,to provide ledger attachment every 8'.Attach ledger to 2-ply end vertical of each truss with one(1)fastener and to each key-block
with one(1)fastener.Refer to Det'. 'for key-block construction and installation information.
7.Install key blocks between the vertical webs of the floor ladder frame to provide ledger attachment every 8".Attach ledger to each 4x4 vertical web with one(1)fastener and to each key-
block with one(1)fastener.Refer to[)eta:!2 for key-block construction and installation information.
REVIEWED FOR
CODE COMPLIANCE
New Home Permit EA
186149
Deck ledger attachment _
engineering for future EAGAN
e,e,oal,e
t deck
BUILDING INSPECTIONS
**Please note m new email address** REVIEWED FOR
Y CODE COMPLIANCE
New Home Permit EA
186149
XJ Deck ledger attachment
Joe BockovenEAGAN
engineering for future
Project Manager, Price Homes deck 011==1 A.
11110 Industrial Circle NW,Suite E,Elk River,MN 55330 BUILDING INSPECTIONS
Office: 763-276-7197
Cell: 763-464-1851
Website: PriceHomes,com
3