Loading...
4898 Brooklyn LaneAddress: 4898 Brooklyn Lane Zip: 55122 Per it: 7 689 THE FOLLOWING ITEMS WERE/WERE NOT COMPLETE AT FINAL INSPECTION ON171 -1 Yes No Comments Final grade - 6" from siding Permanent steps - garage Permanent steps - main entry Permanent driveway Permanent gas Retaining Wall or 3:1 Max Slope Sod/Seeded lawn Trail/curb damage Porch Lower level finish 70 Deck '10 Fireplace ; 4 • Verify with your builder that roof test caps from the plumbing system have been removed. • Turn off water supply to the outside lawn faucets before freeze potential exists. • Call the City's Engineering Department at 651-675-5646 prior to working in right-of-way or installing irrigation system. BUILDING INSPECTOR: O I-0(Y 8Lk&m 'I L*1 Address: 4898 Brooklyn Lane Zip: 55123 Permit: 73689 Lot: 5 Block: 1 Subdivision: Homestead Village THE FOLLOWING ITEMS WERE/WERE NOT COMPLETE AT FINAL INSPECTION ON ?)10 Yes No Comments Final grade - 6" from siding Permanent steps - garage Permanent steps - main entry Permanent driveway Permanent gas Retaining Wall or 3:1 Max Slope Sod/Seeded lawn Trail/curb damage Porch Lower level finish Deck Fireplace AA; n El C36 jz? • Verify with your builder that roof test caps from the plumbing system have been removed. • Tom off water supply to the outside lawn faucets before freeze potential exists. • Call the City's Engineering Department at 651-675-5646 prior to working in right-of-way or installing irrigation system 4 BUILDING INSPECTOR: CONTRACTOR; Brandt Anderson Homes 4555 Erin Drive • Suite 120 Eagan, MN 55122 $u' ot-nna L. r- Judi, ? 7'71a S_ t/u.c 9OL -U x:33(,91 $Sooq.fq ffir 43 YO. 50 RESIDENTIAL A -4-3& i BUILDING LICATIOl? .So - 2006 PERMIT APP City Of Eagan 3830 Pilot Knob Road, Eagan MN 55122 Telephone # 651-675-5675 FAX # 651-675-5694 New Construction Requirements 3 registered site surveys showing sq. R. of lot sq. ft. of house; and g jl roofed areas (20% maximum lot coverage allowed) f(5. VJ 2 copies of plan showing beam & wing sizes; poured found design, etc. 1 set of Energy Calculations 3 copies of Tree Preservation Plan if lot platted after 7/V93 fJ C) Rim Joist Detail options selection sheet (buildings with 3 or less units) Minnegasco mechanical ventilation form Remodel/Repair Requirements 2 copies of plan showing footings, beams, joists 1 set of Energy Calculations for heated additions 1 site survey for additions & decks Addition -indicate if on-site septic system s?? ?3tAS K#ro o.l9 1 -1 1 -1 ce On1 Certpf rvey Recd 4 _N TreePres Plan Recd ` ; '4 _ , Tree`'Pres;Requlred°°-<;?<;?,._Y; _Wt Oiisite:SepticSystem„"i`;`'_Y. IN "tic 10 Q Date Site Address 7 ?" a rook 6L4?1 O 0?u Construction Cost I? L c n Q Unit/Ste # Description of Work A- cJ 'IW i rt Ho in e Multi-Family Bldg - Y - N Fir'eplace(s) - 0 1 _ 2 Property Owner r J I A2, 5 Tele hone # 5.2) 1012 IE 11 X 12 fl5'O2- 30 Contractor Bralr a 1 / d ej s° - Y ? ne S MAY 0 9 2006 Address 1J5 5 State 5 5-iln I/ ri Ve 17 City ECc,G zip r/2 2 Telephone # 0 ?-) S a-r- l ?S?z3 d COMPLETE THIS AREA ONLY IF CONSTRUCTING A NEW BUILDING - Minnesota Rules 7670 Category I _ Minnesota Rules 7672 Energy Code Category . Residential Ventilation Category 1 Worksheet • New Energy Code Worksheet (+i submission type) Submitted Submitted . Energy Envelope Calculations Submitted In theicst 12 months, has the City of Eagan issued a permit for a similar Ian based on a master plan? Yom, Y _ N If yes, date and address of master plan: irSrr9 2 7cu i h,5 wr+ Licensed Plumber _T u, 7 Pfn rsryt Telephone #('7,63 1116-610C Mechanical Contractor Or Aa,6 n J' c Telephone #1152) h13/- 5932 Sewer/Water Contractor ? ?e-f- L((A v a. ir7 e Telephone # (75 fat{ - ?cx g I hereby apply for a Residential Building Permit and acknowledge that the information is complete and accurate; that the work will be in conformance with the ordinances and codes of the City of Eagan and the State of MN Statutes; I understand this is not a permit, but only an application for a permit, and work is not to start without a permit; that the work will be in accordance with the approved plan in the case of work which requires a review and approval of plans. 41nAW heekr '?ran,c?l ?n?elson Applicant's Printed Name ?prn ?/ pplicant's Signature DO NOT WRITE BELOW THIS LINE Sub Types ? 01 Foundation ? 07 05-plex ? 13 16-plex ? 20 Pool ? 30 Accessory Bldg 02 SF Dwelling ? 08 06-plex ? 16 Fireplace ? 21 Porch (3-sea.) ? 31 Ext. Alt - Multi 03 01 of xplex ? 09 07-plex ? 17 Garage ? 22 Porch/Addn. (4-sea.) ? 33 Ext. Alt - SF ? 04 02-plex ? 10 08-plex ? 18 Deck ? 23 Porch (screen/gazebo) ? 36 Multi Misc. ? 05 03-plex ? 11 10-plex ? 19 Lower Level ? 24 Storm Damage ? 06 04-plex ? 12 12-plex ? 25 Miscellaneous Work T es 31 New ? 35 Int Improvement ? 38 Demolish Interior ? 44 Siding ? 32 Addition ? 36 Move Building ? 42 Demolish Foundation ? 45 Fire Repair ? 33 Alteration ? 37 Demolish Buildi ng* ? 43 Reroof ? 46 Windows/Doors ? 34 Replacement *Demolition (Entire Bldg) - Give PCA handout to applicant Description: Water Damage _ Yes Valuation /;,/ d? Occupancy 'I /C'3 MCES System 100% or 2 Plan Review 5% _ Census Code /c9? Zoning City Water 5 SAC Units O / Stories / Booster Pump # of Units 0d2 Sq. Ft. /?t67 PRV XS # of Bldgs 0/ Length l°ep Fire Sprinklered Type of Const Width J6/ REQUIRED INSPECTIONS Footings (new bldg) A Sheetrock Footings (deck) g Final/C.O. Footings (addition) _ Final/No C.O. Foundation _ HVAC Drain Tile Other _ Roof Ice & Water Final Pool _ Ftgs _ Air/Gas Tests _ Final - X Framing _ _ Siding - Stucco Lath _ Stone Lath X Brick Z( Fireplace X R.I. ZAir Test k Final _ Windows j Insulation 1- _ Retaining Wall Approved By: _ Base Fee v U Surcharge Plan Review MC/ES SAC City SAC Utility Connection Charge S&W Permit & Surcharge Treatment Plant License Search Copies Other Total Building Inspector REScheck Compliance Certificate 2000 Minnesota Energy Code REScheck Sotware Version 3.6 Release la Data filename: C:\Program Files\Check\REScheck\Eagan PROJECT TITLE: Eagan Twin Homes - L/O Lot COUNTY: Dakota STATE: Minnesota ZONE: 2 CONSTRUCTION TYPE: Single Family WINDOW / WALL RATIO: 0.13 DATE: 05/05/06 DATE OF PLANS: 5/5/06 PROJECT DESCRIPTION: 4898 Brooklyn Lane DESIGNER/CONTRACTOR: Brandl Anderson Homes 952-898-0230 COMPLIANCE: Passes Maximum UA = 393 Your Home UA = 350 10.9% Better Than Code (UA) All Ceilings: Raised or Energy Truss Exterior Walls: Wood Frame, 16" o.c. Picture Windows: Above-Grade:Vinyl Ftame:Double Pane with Low-E SH/Sliders/SGD: Above-Grade: Vinyl Frame:Double Pane with Low-E Front Door: Solid Garage / House Door. Solid Basement Wall 1: Solid Concrete or Masonry Wall height: 8.0' Depth below grade: 7.5' Insulation depth: 8.0' Floor 1: All-Wood Joist/Truss:Over Unconditioned Space Furnace 1: Forced Hot Air, 90 AFUE Proposed and Maximum U-Factor Averages Above-Grade Windows and Glass Doors Includes Foundation Windows > 5.6 f2 Floors Over Unconditioned Space Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R-Value U-Fact IjA 1422 38.0 0.0 36 2469 19.0 0.0 125 12 0.330 4 303 0.350 106 20 0.400 8 18 0.110 2 852 5.0 0.0 69 8 30.0 0.0 0 Proposed Maximum Average U-Factor Allowed U-Factor 0.349 0.370 0.033 0.033 COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2000 Minnesota Energy Code requirements in REScheck Version 3.6 Release Is (formerly MECcheck) and to comply with the mandato requirements listed in the REScheck Inspection Checklist. Builder/Desi Date 05/24/2006 21:54 9528911656 Date: 5/25/2008 Revision Date: 5/25!2006 Site information Address 1: 4898 BROOKLYN LN Address 2: City: EAGAN County: DAKOTA APDIICation Information Business Name: AIR MASTERS INC Contact Person: BRIAN KUHN Office Ph: 952-431-5932 Fax: 952-891.1856 AIR MASTERS INC PAGE 02 New Construction Project #: 050030096 Lot 5 Block: 1 Subdivision: HOMESTEAD VILLAGE MN Contractor License* Cell Ph: 952-292-0822 Address 1: 5885 149TH ST W #101 City: APPLE VALLEY State: MN Zip Code: 55124 House Details Square Feet 2792 sq. ft. Avg. Ceiling Ht 9 ft. Number of Bedrooms: 2 Ventilation Total Ventilation Capacity : 110 ohm Minimum Continuous Ventilation :45cfm. Continuous Ventilation Provided: Exhaust 70 cfm Intermittent ventilation satisfied by OTHER exhuast appliance. Corn on Apeftee Water Heater: Power Vent Input BTUs: 45,000 Independently Vented Fumace/Boiler. Direct Vent/Sealed Combustion Input BTUs: 70,000 Independently Vented other Combustion Anolianees Gas Fired Direct Vent Fireplace(s): Yes Gas Fired Natural Draft Fireplace(s): No E ha E ui rrt ,st Exhaust Ventilation Capacity (cfrn): 70 Exhaust Fan Rating (cfm): 50 Make-Uo Air No Make-Up Air Required by Code Gas Fired Power Vent Fireplace(s): No Solid Fuel Appliance(s): No Clothes Dryer (cfm): 136 Combustion Air Round Rigid Required: 4 inches or Insulated Flex. 5 inches Applicant Name (Print): 1 ?N FCUPAJ Signature/Date: ?? SJt Code Official (print): Signature/Date: ® 2004 CentetPoint Energy Minnegasco, 2004 Mechanical Code Guidelines. Page 1 LOT SURVEY CHECKLIST FOR RESIDENTIAL BUILDING PERMIT APPLICATION (f e PROPERTY LEGAL: S E I G I Ptme-skoa DATE OF SURVEY: .J3701 S 3 LATEST REVISION; c O z DOCUMENT STANDARDS ? ? • Registered Land Surveyor signature and company ? ? • Building Permit Applicant ? ? • Legal description ? ? • Address a ? ? • North arrow and scale _a ? ? • House type (rambler, walkout, split w/o, split entry, lookout, etc.) ,g' ? ? • Directional drainage arrows with slope/gradient % ? ? • Proposed/existing sewer and water services & invert elevation ? ? • Street name A ? ? • Driveway (grade & width - in R/W and back of curb, 22' max.) ? ? • Lot Square Footage ? ? • Lot Coverage ELEVATIONS Existing ,' ? ? • Property comers jl ? ? • Top of curb at the driveway and property line extensions jd ? ? • Elevations of any existing adjacent homes ? ? • Adequate footing depth of structures due to adjacent utility trenches ? ? • Waterways (pond, stream, etc.) Proposed Jd' ? ? • Garage floor z ? 0 • Basement floor J2 ? ? • Lowest exposed elevation (walkout/window) a ? ? • Property corners ,H ? ? • Front and rear of home at the foundation PONDING AREA (if applicable) ? a ? • Easement line ? Z ? • NWL ? Z ? • HWL ? jd ? • Pond # designation ? g ? • Emergency Overflow Elevation ? !d ' ? • Pond)Wetland buffer delineation Y • Shoreland Zoning Overlay District Y Conservation Easements 2 ? ? • Lot lines/Bearings & dimensions ? ? • Right-of-way and street width (to back of curb) 19 ? ? • Proposed home dimensions including any proposed decks, overhangs greater than 2', porches, etc. (i.e. all structures requiring permanent footings) ? ? • Show all easements of record and any City utilities within those easements 7' ? ? • Setbacks of proposed structure (i sideyard setback of adjacent existing structures 'z ? ? • Retaining wall requirements: Reviewed By ®R t( Date G:/FORMS/Building Permit Application Rev. 11-26-04 MendowHeights Office P INEERengineering Coon Ra p ids Office 2422 Enterprise Drive CIVIL ENGINEERS LAND PLANNERS LAND SURVEYORS LANDSCAPEARCtDTECrS 20185th Avenue N.W. Mendota Heights, MN 55120 Coon Rapids, MN 55433 (651) 681 1914 Fax:681 9488 Mendota Heights Office (763) 783 1880 Fax:783 1883 Certificate of Survey for: BRANDL ANDERSON HOMES ??`?! 489$ AND 4894 BROOKLYN LANE, EAGAN, MN _ f J BUYER: SPEC MODEL:EAGAN TWIN HOME 3:1 Maxlfwn 39,SQ FT REAS' ="3;689'sq: ft.? 7 % SQ FT / // 4CH MARK: D NUT HYDRANT L4-5 B? =V.=946.8 / / !1O 0 d. TI V/ Ilff JHI Wining WWI Will Be Required N83°2"E 4 3.48 ELEV.=945.08 I A ?-----? PROPOSED NOTE: PROPOSED GRADES SHOWN PER GRADING PLAN BY. PIONEER ENGINEERING BUILDING NOTE: BUILDING DIMENSIONS SHOWN ARE FOR HORIZONTAL AND VERTICAL LOCATION ?? O) OF STRUCTURES ONLY. SEE ARCHITECTURAL PLANS FOR BUILDING AND FOUNDATION DIMENSIONS. NOTE: NO SPECIFIC SOILS INVESTIGATION HAS BEEN COMPLETED ON THIS LOT BY THE ?, /? I? 1D SURVEYOR. THE SUITABILITY OF SOILS TO SUPPORT THE SPECIFIC HOUSE Y PROPOSED IS NOT THE RESPONSIBILITY OF THE SURVEYOR, NOTE: THIS CERTIFICATE DOES NOT PURPORT TO SHOW EASEMENTS OTHER THAN By THOSE SHOWN ON THE RECORDED PLAT. Date NOTE: CONTRACTOR MUST VERIFY DRIVEWAY DESIGN, EAGAN ENGINEERING DEFT. NOTE: BEARINGS SHOWN ARE BASED ON AN ASSUMED DATUM U " 0 PLAN SERVICE LOT 5 LOT 6 INVERT ELEVATION (934.6) (934.0) per plaA. WE HEREBY CERTIFY TO BRANDL ANDERSON HOMES THAT THIS IS A TRUE AND CORRECT REPRESENTATION OF A SURVEY OF THE BOUNDARIES OF: LOT 5 AND 6, BLOCK 1, HOMESTEAD VILLAGE DAKOTA COUNTY, MINNESOTA IT DOES NOT PURPORT TO SHOW IMPROVEMENTS OR ENCROACHMENTS, EXCEPT AS SHOWN, AS SURVEYED BY ME OR UNDER MY DIRECT SUPERVISION THIS 28TH DAY OF FEBRUARY. 2006. SCALE : 1 INCH = 20 FEET PROPOSED BUILDING F V ?\ LOWEST FLOOR ELEVATION: 11'? ) TOP OF BLOCK ELEVATION: Q FFtfl. GARAGE SLAB ELEVATIONS TOB ® LOOKOUT ELEVATION: QA2-,?4') X 000.00 DENOTES EXISTING ELEVATION OOO.DO ) DENOTES PROPOSED ELEVATION DENOTES DRAINAGE AND UTILITY EASEMENT -o- DENOTES DRAINAGE FLOW DIRECTION -A- DENOTES SPINE D DENOTES OFFSET HUB PIONEER Dan R. Westergren License No. AL¢-14-21?01 10:23am From- Fax: 952-898-0232 To: Fax: Date: 08-14-06 Pages: Comments: 68126a T-814 P.001/002 F-n61 Because of the numerous field conditions encountered, it is not always possible to identify a firestop system that has been tested /classified by a nationally recognized independent testing laboratory (such as Underwriters Laboratories, Factory Mutual, Omega Point, etc.). In such a case, an Engineering Judgment ("EX) may be appropriate. An EJ represents a firestop system that would be expected to pass the stated ratings and requirements if tested. All Huh EJ's are designed in accordance with the International Firestop Council ("IFC") guidelines. These EJ's are designed by our experienced degreed fire protection engineers using, as the basis for our opinion: relevant 3-party classified systems tested in accordance with ASTM E-84, ASTM E-110, ASTM E-136, ASTM E-814, ASTM E-1966, ASTM E-2307, ULC-S115-95M, UL 263. UL 723, UL 1479, or UL 2079, • wide-ranging related internal testing of our firestop products, and • extensive knowledge and experience of the performance characteristics of Hilt firestop products, and firestopping technology generally- Pursuant to IFC guidelines, each EJ is intended for one specific jobsite, since even slight variances from one application to the next can affect system performance. Best regards, Clay Hensley Chemicals Business Unit I Fire Protection Department Hilti North America 5400 S 122nd E Ave I Tulsa, OK 74146 P 918.252-6216 I F 918-254.1679 E day.hensley@hiltl.cam www.us.hild.com To: Bob q nt,{-14-2006 10:23am From- T-814 P.002/002 F-561 DS ENGINEERING JUDGMENT FIRESTOP DETAIL PROJECT : HOMESTEAD VILLAGE CONTRACTOR : BRANDL ANDERSON F-RATING =1-HR. FRONT VIEW A G, SECTION A-A Iv- 1. GYPSUM WALL ASSEMBLY (UL/cUL CLASSIFIED) (1-HR. FIRE-RATING). 2. MAXIMUM 2" NOMINAL DIAMETER PVC PLASTIC PIPE. 3. MINIMUM 5/8" DEPTH HILTI FS-ONE INTUMESCENT FIRESTOP SEALANT. 4. SHEET METAL COVER PLATE (MIN. 18 GA.) ATTACHED WITH THE APPROPRIATE HILTI ANCHORS. 5. HILTI 1-314" RETAINING COLLAR WRAPPED AROUND PIPE, OVERLAPPING MINIMUM 2", AND COMPLETELY FILLED WITH HILTI FS-ONE INTUMESCENT FIRESTOP SEALANT. 6. HILTI RETAINING COLLAR CLAMP FASTENED AT MID-HEIGHT OF RETAINING COLLAR. 7. HILTI 114" TOGGLER BOLTS TO FASTEN EVERY OTHER TAB OF RETAINING COLLAR. NOTES : 1. MAXIMUM SIZE OF OPENING = 2-112" x W. 2. ANNULAR SPACE = MINIMUM 0", MAXIMUM 1-1/2". 1 PIPE MAY BE INSTALLED AT AN ANGLE NOT GREATER THAN 45° FROM PERPENDICULAR. THIS ENGINEERING JUDGMENT REPRESENTS A FIRESTOP SYSTEM THAT WOULD BE EXPECTED TO PASS THE STATED RATINGS IF TESTED (REFERENCE : UL SYSTEM NO. W-L-2251 & C-AJ-2110) HILTI, c. Sheet 1 of 1 Drawing No. Tulsa, Oklahoma ma USA (800) 879.8000 Scale 11 6132" - 68126a Designed by ?/ Hilti Firestop Systems cI/ Dare Aug. 1i,zsos and Education Sarah Brandel From: Mary Granley Sent: Tuesday, June 16, 2009 114 PM To: Dale Schoeppner; Terry Zelenka Cc: Sarah Brandel Subject: FW: Brandl Anderson New Construction - 4898 Brooklyn Lane, Eagan FYI Mary Granley I Senior Code Enforcement Technician I City of Eagan t? City Hall 13830 Pilot Knob Road I Eagan, MN 55122 1 (651) 675-5690 1(651) 675-5694 (Fax) I mgranley cityofeagan.com City of Ea fi THIS COMMUNICATION MAY CONTAIN CONFIDENTIAL AND/OR OTHERWISE PROPRIETARY MATERIAL and is thus for use only by the intended recipient. If you received this in error, please contact the sender and delete the e-mail and its attachments from all computers. From: Li, Susanna [mailto:Susanna.Li@ecolab.com] Sent: Tuesday, June 16, 2009 11:41 AM To: CodeEnforcement Cc: Peg Cowart Subject: Brandl Anderson New Construction - 4898 Brooklyn Lane, Eagan TO: City of Eagan CC: Brandl Anderson Warranty Department Dear Sir, I write to report that there are problems of some concrete slabs of our new homes. In particular, the concrete slab on the entry way of my home has a linear crack of appr. 2 feet in length and 1 /4 inch in width. The slab was broken and not leveled due to the crack. My understanding from my neighbors is that theirs also had problems on this area and some were worse. Although my home was closed on October 6, 2006, it didn't pass the City's Inspection in this regard. The formal occupation permit only issued in or around September 2008 after Inspector Terry reinspected the concrete slab. However, a couple of month later, the crack was found. I would believe that the City Inspector somehow noticed there was something not in order and asked Brandl Anderson to rectify the problem. After discovery of the crack, I immediately informed Brandl Anderson but they replied they couldn't do anything (they didn't even pay a visit to look at this) because of weather condition. Since the crack has been found, I've been communicating with their Warranty Department and wanted to have this repaired as soon as possible but was given unreasonable excuse every time. I have been patiently waiting for the right weather to come but the need of the repair has been consistently neglected. Furthermore, it is worrisome to the homeowners that there could be concrete foundation problems of the homes. We've seen the outside, what about the areas that are not easily exposed? I would like to make this known to your office and have it put in the record. Thank you for your time. Susanna Li 2017-Sep-13 02:18 PM Greenguard Construction 507-208-4336 11/13 Use BLUE or BLACK Ink 41111‘ For Office Uae ,�.' Cityof Eaall Permit i�//�✓/�� CL Permit Fee: ` gill° � 3830 Pilot Knob Road 94 34? Eagan MN 55122 Date Received: Phone;(651)676.5676 > puiidinainsoectionslacltvofeaslan.com Staff: 2017 RESIDENTIAL BUILDING PERMIT APPLICATION Date: 9/13/17 Site Addreee:4894 -.(.roes;I n U'(qg9()) Unit Ii: Name: Homestead Village HOA Phone:Ali (612)242-0754 Resident/ Owner Address/City I Zip: Applicant is; Owner X Contractor Re-Shin le Dwellin Type of Work Description of work: g g Construction Cost: $15,000.00 9t,t o Multi-Family Building:(Yes X /No �) Company: GreenGuard Construction Contact Pat Addy Contractor Addreee: 2915 Waters Road #101 city. Eagan. State: MN Zip: 55121 Phone; (612)760.2033 cell Email: pet.eddy@greenguardconstructlon.com License#: BC633970 Lead Certificate ii: nat103540-2 If the project Is exempt from lead certification,please explain why: COMPLETE THIS AREA ONLY IF CONSTRUCTING A NEW BUILDING In the last 12 months,has the City of Eagan Issued a permit for a similar plan based on a master plan? Yes X No if yes,date and address of master plan: Licensed Plumber: Phone; Mechanical Contractor; Phone; Sower&Water Contractor: Phone: Fire suppression Contractor; Phone: NOTE:Plans end supporting documents that you submit ere considered.to.be public Information. Portions of the information may be classified as non-public If you provide specific reasons that would permit the.City to conclude that they are trade secrets. You may subscribe to receive an electronic notification from the City of proposed ordinances by signing up for an email update on the City's website at www.citvofeaoan.comisubscribe. Exterior work authorized bye building permit Issued in accordance with the Minnesota State Building Coda must be completed within 180 days of permit Issuance. CALL BEFORE YOUDIG. Call Gopher State One Call et(851)454.0002 for protection against underground utility damage. Call 48 hours before you Intend to dig to receive locates of underground utilities. www.000heretaleonecell.orq I hereby acknowledge that this Information is complete and accurate;that the work will be In oonformono th the ordinances and codes of the City of Eagan;that I understand this Is not a permit,but only an application for a permit,and work Is n ate without permit;that the work will be In accordance with the approved plan In the case of Work which requires a review and approval of pi . xPat Addy Applicant's Printed Name Applicant's gnature Page 1 of 3 For Office Use//G,j/ ti'i � � ��> :::;ee: .0 E AG A N * ,, „�. : [ 16 ...,2Z, RECCE Date Received: / 15 7.— / P 3830 PILOT KNOB ROAD I EAGAN, MN 55122-1810 VED (651)675-5675 1 TDD: (651)454-8535 1 FAX: (651)675-5694 Staff: . "1104 buildinginspectionsAcityofeagan.com MAY 1 2018 L 11 ---_, 2018 RESIDENTIAL BUILDING PERMIT APPLICATION Date: Site Address: Unit#: Name: .,.,_J e-' `c 4 r &c WlOL Phone: Restdentt / PP .. 7 („ C <Owner Address/City/Zip: 1-8"( � Ei ( 7 i Applicant is: Owner rx Contractor / 6 Chir/r 7r Description of work: R e,it v C-e /--ki e c d'C[1-19. £c k`,k w,,C.5 ;, , t :` ref'Work p c L' /S Construction Cost: 6-`7$v Multi-Family Building: (Yes /No ) MVP Construction, LLC Contact: /if /(- 3400 36th Avenue NE City: Contractor St. Anthony, MN 55418 �[ �J 6I - :4-3 7 d%�_�maiI: .711k/16W51—Et'/' �iztel'/ LC'7'y7 License#: 1 C /&(. 2 Lead Certificate#: / L ff ' .- / If the project is exempt from lead certification, please explain why: COMPLETE THIS AREA ONLY IF CONSTRUCTING A NEW BUILDING In the last 12 months, has the City of Eagan issued a permit for a similar plan based on a master plan? Yes No If yes,date and address of master plan: Licensed Plumber: Phone: Mechanical Contractor: Phone: Sewer&Water Contractor: Phone: Fire Suppression Contractor: Phone: NOTE:Plans and supporting documents lhat you submit are considered to be public information. Portions of the in formation maybe classified as non <ublrc if du royide 3.ecific reasons that wank R ermit the Ci to conclude that the are trade secrets. „,. You may subscribe to receive an electronic notification from the City of proposed ordinances by signing up for an email update on the City's website at www.cityofeagan.com/subscribe. Exterior work authorized by a building permit issued in accordance with the Minnesota State Building Code must be completed within 180 days of permit issuance. CALL BEFORE YOU DIG. Call Gopher State One Call at(651)454-0002 for protection against underground utility damage. Call 48 hours before you intend to dig to receive locates of underground utilities. www.gopherstateonecall.orq I hereby acknowledge that this information is complete and accurate;that the work will be in conformance with the ordinances and codes of the City of Eagan; that I understand this is not a permit, but only an application for a permit, and work is not to start without a permit; that the work will be in accordance with the approved plan in the case of work which requires a review and approval ofplans. 1 / Vis' 4.';' A�:,.. Applicant's Printed Name Applicant's Sig ature j-/SV , ,,,,ediiiv,,i 1444 'i-.) - DO NOT WRITE BELOW THIS LINE SUB TYPES Foundation _ Fireplace _ Porch(3-Season) _ Exterior Alteration(Single Family) — Single Family _ Garage _ Porch(4-Season) _ Exterior Alteration(Multi) Multi Deck _ Porch(Screen/Gazebo/Pergola) _ Miscellaneous 01 of_Plex _ Lower Level _ Pool _ Accessory Building WORK TYPES New _ Interior Improvement Siding _ Demolish Building* Addition _ Move Building _ Reroof _ Demolish Interior _ Alteration _ Fire Repair _ Windows _ Demolish Foundation R. Replace _ Repair Egress Window Water Damage Retaining Wall *Demolition of entire building-give PCA handout to applicant DESCRIPTION Valuation // — Occupancy .Jr.(2c"Z- MCES System Plan Review Code Edition Mil 2o1S— SAC Units (25%_100% )0) Zoning P A City Water Census Code Stories Booster Pump #of Units Square Feet PRV #of Buildings Length /'Z- Fire Suppression Required Type of Construction ti 15 Width /J REQUIRED INSPECTIONS Footings(New Building) Meter Size: Footings (Deck) Final/C.O. Required Footings (Addition) ,)/ Final/No C.O. Required Foundation Foundation Before Backfill HVAC_Gas Service Test Gas Line Air Test Roof: Ice&Water _Final Pool:_Footings Air/Gas Tests _Final Framing 30 Minutes 1 Hour Drain Tile Fireplace: Rough In Air Test Final Siding:_Stucco Lath _Stone Lath _Brick_EFIS Insulation Windows Sheathing Retaining Wall:_Footings_Backfill_Final Sheetrock Radon Control Fire Walls Fire Suppression:_Rough In Final Braced Walls Erosion Control Shower Pan_ Other: / Reviewed By: 0/ tt inf.1047/9 , Building Inspector RESIDENTIAL FEES i2 ' 5*- /t/t- 4'/s; p' Base Fee Surcharge ›.47-e), /�f 4 S 4- .62 'y`' ^ 1 Plan Review MCES SAC City SAC Utility Connection Charge S&W Permit&Surcharge Treatment Plant Copies 7-1 St. . ZS �OD TOTAL Page 2 of 3 PERMIT City of Eagan Permit Type:Plumbing Permit Number:EA175239 Date Issued:03/22/2022 Permit Category:ePermit Site Address: 4898 Brooklyn Lane Lot:5 Block: 01 Addition: Homestead Village PID:10-33475-01-050 Use: Description: Sub Type:Fixtures Work Type:Replace Description:Kitchen Meter Size Meter Type Manufacturer Serial Number Remote Number Line Size Comments:Please call Building Inspections at (651) 675-5675 to schedule a final inspection. All tiled shower bases require a water test. Fee Summary:PL - Permit Fee (miscellaneous)$59.00 0801.4087 Surcharge-Fixed $1.00 9001.2195 $60.00 Total: I hereby acknowledge that I have read this application and state that the information is correct and agree to comply with all applicable State of Minnesota Statutes and City of Eagan Ordinances. Contractor:Owner:- Applicant - Jeffrey & Ruth Erdmann 4898 Brooklyn Ln Eagan MN 55122 Spring Plumbing Llc 8220 Ravenrock Road Rockford MN 55373 (763) 614-7963 Applicant/Permitee: Signature Issued By: Signature