Loading...
559 Caylin CtAddress: 559 Caylin Ct Zip: 55122 Permit: 78651 THE FOLLOWINC ITEMS WERE/WERE NOT COMPLETE AT FINAL INSPECTION ON :oil: 2_:? Yes No Comments Final grade - 6" from siding Permanent ste s- gara e // Permanent ste s- main ent r/ Permanent driveway Permanent as Retainin Wall or 3:1 Max Slo e Sod/Seeded lawn Trail/curb dama e Porch Lower level fuush Deck Fireplace . Verify with your builder that roof test caps from the plumbing system have been removed. • Tum off water supply to the outside lawn faucets before freeze potential eacists. • Call the City's Engineering Department at 651-675-5646 prior to working in right-of-way or installing irrigation system. 4 BUILDING INSPECTOR: GBldg Insp/Forms/20071Chxklists Jlrna???a- ``'-F?Lc?C'dnno((?- Date: 6/22/2007 Revision Date: 6/22/2007 Site Information Address 1: 559 Caylin Ct Address 2: City: Eagan County: Dakota Aaalication Information Business Name: Manley Brothers Contact Person: Brian Christopherson Office Ph: 952-997-6100 Fax: Cell Ph: Address 1: 14815 Energy Way City: Apple Valley State: Mn Zip Code: 55124 House Details Square Feet: 4297 sq. ft. Avg. Ceiling Ht: 9 ft. Ventilation : Balanced Total Ventilation Capacity : 169 cfm. Minimum Continuous Ventilation :75cfm. Intermittent Ventilation: 94 cfm. New Construction Project #: Lot: 14 Block: 1 Subdivision: Long Acres 2nd Addition MN Contractor License #: Number of Bedrooms: 4 Combustion Appliance Water Heater: Power Vent Input BTUs: 46,000 Independently Vented Furnace/Boiler: Direct VenUSealed Combustion Input BTUs: 100,000 Independently Vented Other Combustion Appliances Gas Fired Direct Vent Fireplace(s): Yes Gas Fired Power Vent Fireplace(s): No Gas Fired Natural Draft Fireplace(s): No Solid Fuel Appliance(s): No Exhaust Eauiament Continuous Exhaust Ventilation Capacity (cfm): NA Clothes Dryer (cfm): 135 Exhaust Fan Rating (cfm): 135 Make-Up Air No Make-Up Air Required by Code Combustion Air Round Rigid Required: 4 inches or Insulated Flex: 5 inches ?oL` ? ApplicantName(print): L. ?J_yoa ?J C? Signature/Date: Code Official (print): Signature/Date: C 2004 CenterPoint Energy Minnegasco. 2004 Mechanical Code Guidehnes. Page 1 i . Ab? Clty Of EBpIl 3830 Pilot Knob Road Eagan MN 55122 Phone: (651) 675-5675 Fax•(651)675-5694 -________________i I For Office Use ? ? Permit#: I Pertnit Fee: ? Date Recewed: ? ? 5[aff: ? J)cc k.. I L - - - - - - - - - - - - - - - - 2008 RESIOENTIAL-SUM)IM PERMiT APPLICATION Date: 9_4-0,s Tenant: Suite a: RESIDENTIOWNER Name: _? o-r4 Caa?o??y Phone: I.Q?2--IIS- SIoC.Q Address 1 City/ Zip. 5501 r_AYL 1,J GT. r?t G^--,J S S I 2 3 Applicant is: _ Owner _ Contractor TYPEOFWORK Description of work: 12> LA I?-?tr??+ oF .4c Construction Cost ?A E56c MuRi-Family Building: (Yes No CONTRACTOR Name: _?on1 C-otJtJDI.t?N License#: Address: SS°f C1h%a L. t?-1 C.T City: fZDc State- HJIJ zip: SS1 Z 3 Phone: u ti -7 IS- 516l.f ContactPerson: -JOr, lArj t`-34 LL!-J COMPLETE THIS AREA ONLY IF CONSTRUCTING A NEW BUIIDING Minnesota Rules 7670 Catesaorv 1 Minnesota Rules 7672 ^ . pesideniial VeMilation Category 1 WorksheeE • New Energy Code Worksheet Energy Code Category Submitted Submitted SubmiSSiOn type) • Energy Envelope Calculations Submitted In the last 12 months, has the Ciry of Eagan issued a permit for a similar plan based on a master plan? _Yes _No If yes, date and address of master plan: Licensed Plumber: Phone: Mechanical Contractor: Phone: Sewer & Water Contractor: Phone: NOTE: Plans and supporting documents that you submit are considered to be public informafion. Porttons ot the information may be c(assified as non-pubiic if you provide specifk reasons lhat would permit the City to conclude that the are trade secrets. ' e;eb;? a^4rou; -dae tFaW, tF.is in+oEmation Is comptele snd acce:rate. ;hai tFe wcrk wili 6e in ccr,for.n::nce wiii• IFc. 2.:.: Eagan; ihat I untlerstard this s npt a permi4 but only an application for a permi6 end work is not to start wilh td a pamit: ih^t rhr ?Y+d, v? _.; Jo i? Cj a,s-6 Yy? ?-- sKe aaaress: S S 9 CAYc. 14 GT, [. r r' L U L l. ? J r DO NOT WRITE BELOW THIS LINE SUB TYPES ? Foundation ? Single Family ? 01 of _ Plex ? 02-Plez ? 03-Plex ? O4-Plex WORK TYPES ? New 14- Addition ? AReration 0 ReplacemeM ? 05-plex ? 06-p1e= D 07-plex ? 0&plex ? 10-plex ? 12-plex ? 76plex O Flreplsce ? Garage -)K Deck ? Lower Level ? Accessory Bullding ? P.orch (3-season) ? Porch (4-soson) ? Porch (scieeN9azebolPergda) ? Storm Damage ? Miscelleneous ? Pool D EriA1L-Mukl O Ext NL - SF ? Nultl Misc. ? Irrterior ImprovertreM ? Siding ? Demolish BuiWing' ? Move Bu{Idimg ? Reroof ? Demdisb IMerior ? Rre Repair ? Windows D Dofnolish FWndsUo^ ? Egress Window ? WaEar Oamage • pemoiition (enNm buildng) - give PCA handou[ to spplicant DESCRIPTION• Valuatlon V 4 Plan Review (25% 100%*tj Census Code # ot Unlts # of Bulldings OccupancY MCES SYsMm Code Editlun , ? ?ka SAC UnFts ZoMng City waRer Stowies Booste? PumP Square Fnet PRV FLe Sptinklers Type of Consx ? Width REDUIRED INSPECTIOPIS Footings (new bW9) ? Footlngs (deck) ? FoOtlngs (additlon) - Fomndatfon Draln Tfle Roof: _Ice8 W ater _Final Framing Flreplace:_R.1. _Air Test _Final ? Insulaibn SAeetrodc ? FinaUC.O. FlnaUNO C.O. HVAC PooL• _FOOtings AidGas Tests _Final - SWing: Swoco Lalh _Stone Latli _Bridc - WtrWrnrs - Ralainirtp Wall Building inBpeCta Reviewed Sy: RESlDElYTIAL FEES: Base Fee Surcharge Plan Review MC/ES SAC City SAC Utility Connection Charge SS1N Pertnit 6 Su?Che?gB Treatmerrt Piatrt Copies Total po ? ? C Page 2 of 3 Surveyor's Certificate SURVEY FOR : Jon er stacy connony DESCRIBED AS :Lat d ,a, alock 1, LONG ACRES 2ND ADDITION, City of Eagan, Dakota County Minnesot an reserving , a easements of record. 955.9 ess.s N83-15'06"E 85.53 e55.7 - 955.9 ° " ---__---1 '. ---- ---- - -I 5 _ , ?-- _ - - - - i --, n I I I •" I 6.0 I `•, 964.2 9 i 963.3 j O I ? I I ? ? z O 65.6 96 J 98 .3 9fi6.4 3 39 6. c0 ?i - - W ? ? fi3.8 ?- N15.00 o 11 O i o i 50 D6dC 2 i 8 963.1 ? a 3 19.00 1 . 66.7 i .50 20 r? N f ? Proposed `'{ I w 2-Story 9'pcw w/o Gara e rO 9 0? m 9703 N u o 11.8 .00 O 96 .6 Nfi 00o p 20.17 D 966.4 . 14.000 1400 1 970 j"? 8 974 _ ? 970J . . 964.9 74.3 ?u O I I / 4 972, ti s7z.s ?ti°yo? ? ? 5? 972 4 L - - - - - - - - - , . o ti 989.9 j - - o 89°40'29"E 43.36 ? 971.9 uCAYLIN COURT 559 66. ty ? Exist. Nome o GF= 975.1 LOT SQ. FOOTAGE = 12,076 HSE. SQ. FODTAGE = 2,474 LOT COVERAGE = 20% PROPOSED ELEVATIONS Tap of Foundation = 974,8 Garage Floor = 974.4 Rasement Floor - 966.1 Aprox. Sewer Service - 960.4 Proposed Elev. Existing Elev. _ Drainage Directions = Denotes Offset Stake = . HEDLUND PLANNlNG 6NG1NB6RING SURV6YING 2005 Pin Oak Drive Eagon, MN 55122 Phone: (651) 405-6600 Fax: (651) 405-6606 t . . ?hm " - 3E ISiEHc„ ,' - , _Ai•,i!- _ S V F't'ii"- , - \' r; . SCALE: i inch - 30 feet BENCHMARK, MIN. SETBACK REQUIREMENTS Front -30 House Side -10 Rear -15 Garage Side-s I HEREBY CERTIFY ThIAT THIS IS A TRUE AND CORRECT REPRESENTATION OF THE BOUNDARIES OF THE A80VE DESCRIBED PROPERN AS SURVE7ED 8Y ME OR UNDER MY OIRECT SUPERVISION ANO DOE5 NOT PURPORT TO SHOW IMPROVEIAENTS OR ENCROACHMENiS, EXCEPT AS SHOWTJ. DA7E _ ! /._1_I O / -11?V • 9/iL(SLfi ? D. LICENSE NUAh9ER 14376 JOB N0: 07R-226 BODKIPAGE. Manley-07 ,S`urveyor's Certificate SURVEY FOR : ion & stacy connony DESCRIBED AS :Loc 14, Block 1, LONG ACRES 2ND ADDITION, City of Eagan, Dakota County, Minnesota ?nd reserving easements of recard. 3:9 RAEVCiP41UPP1 slOpBffi 955.9 or RoWning HNaII HHih1 ?s 7 g ? Requir? _A 956.5 N83°15'06"E 85.53 - ? 955.9 ° -- ? Y-- 5 ? 0 fujor? 964.2 ??? 966.3 <V ? I p 965.6 966.4 967.7 O 96 .3 30. 6-^- I??N Exist. Homryryry 1.89 00 N15.00 0 967.2 I l s ? o GF= 975.1 i p0 963 Q ?'0 0 1150 g ryI?nn 0 2050 .i ?I N6.7 ii ? P? • ? Proposed P I 7 [.n i?w N9p 3'9 n ? ? I J 2-Story Garoge o l {? g'pcw w/o N 97D.,3I ? I 11.8 3 OO 96 .6 N6.OOin o 2017 0 ? 4,06 ? gggggg 140 ° '-5 - L 970J 966.4 1 970.9 - 964.9 974.1 74.3 I' . - ?4 ??•J e72 972r6 972.4 L -- ? 9699 , $z? ° o(?apg?4?#Q?ap?f?5 ??QOt?e?o?c? 969.5 0 ? ?40?,0 U76lP?OG?AI511 ?InS ??D '6N89°40'29"E 4136 5' ? a C69 7 O ? z -CAYLIN COURT Ha? ------- ¢ o ? 559 ? aw? ? z H '? ? c7 LOT SQ. FOOTAGE = 12,076 ? w a HSE. SQ. FOOTAGE = 2,474 ? ? `' ? LOT COVERAGE = 20% o a?".?w ? m o PROPOSED ELEVATIONS ,• ", BENCHMARK, Top of roundation = 974.8 ;_<(IC = Garage Floor = 974,4 SUid?4'OR Basement Floor = 966.1 ` Aprox. Sewer Service = 960.4 :?'f?,;• _ ?L? s, •;,C ?'? Pro osed Elev. MIN. SETBACK REQUIREMENTS P =0 Existing Elev. Drainage Directions = Front -30 Hnuse Side -10 Denates Otfset Stake = • scnLE: i inch = 30 feet Rear -15 Garage Side-5 JOB NO• IfEDLUND I HEREBV CERTIFY THAT THIS IS A TRl1E AND CORRECT REPRESENTATION 07R-226 OP iHE BOUNOARIES OF iHE ABOVE DESCRIBED PROPERTY AS SURVEYED BY ME OR UNDER MV OIRECT SUPERVISION AND DOES NOT PURPORT TO 800KPAGE: PLANNINC BNGlN66RlNC SURV6YLNC SHOW IMPROVEMENTS OR ENCRDACHAAENTS, EXCEPT AS SHOWN. 2005 Pin Oak Drive ' ,/? • Eagon, MN 55122 DATE _7/?r/O7 ?.J • CAO FILE: Phone: (651) 405-6600 E F D. LINDGREN, L4 SURVEYOR Manle 07 Fax: (651) 405-6606 IN SOTA LICENSE NU ER 14376 Y aL 7?&-5'1 ?f7343, 2006 RESIDENTIAL BUILDING PExNUT aPrLicaTiorrFL 7g5q_5- `>'o• y6 City Of Eagan 3830 Pilot Knob Road, Eagan MN 55122 Telephone # 651-675-5675 FAX # 651-675-5694 Nevr Consiruction Reauirements a?3 registered sRe surveys showing sq. R of lot, sq. ik of house; and all roofed areas (20% mazimum bt ooverege albwed) ?2 copies of plan showing beam & window s¢es; poured tound design, etc. ?1 set of Energy Calwla6ons 3 copies of Tree Preserva4on Plan if lot platted after 711193 ?Rim Joat Defail Options seleGion sheet (buildings with 3 orless un'tls) VMinregasco mechan'xal ventlation form RemodellReoair Reaulrements 2 copies of plan showing footings, beams, josts 7 set of Energy Galculations for heated additions 1 sAe survey for addNons & dedcs AddBron . indicate if ar-sde sepfic sysfem .Ub d r,? 7KZ?9t?, 9n. sn .S?rtv 1`?a7 ? ?? ??1•.34 biffce i7'se orilv CeiloF-Surt%eyRecd;.e',z-_i/'Y,",;._,1J ? Tree'Pres Plan' Re?d->? = =_Y,?'_j"f?, Tre@ P-? Reqwredx: Or?'siteSe r ptlc;$pstem" _;:•=y 7 3D Date /Z$ / 0-7 Construction Cost as A30 0, o00 SiteAddress S?S e. LI UniUSte # Description of Work EpKwo% 06 511341.$ 5?iHiLtj YWHE. Multi-Family Bldg _ Y-2?. N Fireptace(s) _ 0 ? 1 _ 2 Property Owner xOtJ [?,p a1?10LL-! Telephone k( Jt12 )-7 15 ^ 5 I OQ Contractor -S otJ C.oPi No%- l.y Address 31 S°I l}}4n f4 A,/E.. .? ' State ("? ?.? Zip 55l 2 3 City"4it,j Telephone #(U12) T 18" SI04 COMPLETE THIS AREA ONLY IF CONSTRUCTING A NEW BUILDING - Minnesota Rules 7670 Cateeorv 1 Minnesota Rules 7672 Energy Code Category . Residentiai Ventllation Category 1 Worksheet • New Energy Code Workshee[ (4 submission Type) Submitted Submitted . . Energy Envelope Calwlations Submitted ° In the last 12 months, has the City of Eagan issued a permit for a similar plan based on a master plan? _ Y ? N If yes, date and address of master plan: ? Licensed Plumber M% D STA,TE. Telephone #((,ps4) q'86- «%r Mechanical Contractor l--,vFGR?'•n?' Telephone #(15L) 471- 5811 Sewer/Water Contractor. S"R?Lk t.9- Telephone #('624 I hereby apply for a Residential.Building Permit and aclnowledge that the information is complete and accurate; that the work will be in conformance with the ordinances and codes of the City of Eagan and the State of MN Statutes;- I understand this is not a permit, but only an application for a permit, and work is not to start without a permit; that the work will be in accordance with the approved plan in the case of work which requires a review and approval of plans. So1.1 C4Q00L,L-/ J?? JUN 2 5 2007 ? ?/?„ Applicant's Printed Name ` Apant's Signqfur ??'?p v ?l DO NOT WRITE BELOW THIS LINE Sub Tvpes ? 01 Foundation ? 07 OSplex ? 13 16-plex ? 20 Pool D 30 AccessoryBldg 93 02 SF Dwelling ? 08 06-plex ? 16 Fireplace ? 21 Porch (3-sea.) ? 31 Ext. Alt - Multi ? 03 01 of _ plex ? 09 07-plex ? 17 Garage ? 22 PorchlAddn. (4-sea.) ? 33 Ext. Alt - SF ? 04 02-plex ? 10 08-plez ? 18 Deck ? 23 Porch (screen/gazebo) ? 36 Multi Misc. ? 05 03-plex ? 11 10-plex ? 19 Lower Level ? 24 Storm Damage ? 06 04-plex ? 12 12-plex ? 25 Miscellaneous Work Tvpes JD 31 New 11,35 1 Int Improvement ? 38 Demolish Interior 0 44 - Siding ? 32 Addition ?.•:::/ ' ? 36 Mova Building ? 42 Demolish Foundation ? 45 , Fire Repair O 33 Afteration ? 37 Demolish Building' ? 43 Reroof ' ?' 46 Windows/Doors ? 34 Replacement 'Demolition (Entire Bldg) - Give PCA handout to appliwnt DeSCriDt1011: Water Damage _ Yes ' Valuation Lj ? Occupancy fz? MCES System Plan Review 100% or _ 25% Census Code /0 1 Zoning City Water SAC Units b? Stories 2 Booster Pump # of Units p/ Sq. Ft. z q b q PRV # of Bldgs ? 1 Length e , Z Fire Sprinklered Type of Const Y,/3 ' Width (Z?O_ REQUIRED INSPECTIONS 10 Footings (new bldg) Sheetrock _ Footings (deck) ?O FinaUC.O. Foorings (addition) FinaUNo C.O. ?0 Foundation HVAC _ Drain Tile Other Roof L Ice & Water _P Final Pool Ftgs Air/Gas Tests Final 10 Fn'n'n8 p Fueplace JO R.I. LP qu Test Siding _ Smcco Lath 1 Stone Lath Brick Y Final Windows ?O Insulation _ Retaining Wall Approved B . '494 ---------- -------- ----- uilding Inspector Base Fee -----------------------------------=--------------- ------ Surcharge ?Pe'n Q°Rf 1-\ Z/U 59')0} • K YSo° Plan Review ?-ww (ra g Z S SS •/C? 'y 3 3. b$ MGESSAC ?iq:5?? i3.'tS?lYeefi? IZ?? S%.F'?X7g•?S City SAC ili 11657 S9, pr-r- Ut ty Connection Charge S&W Permit & Surcharge 1532 5*9 ' &',x ? ?7 $ Treatment Plant UA r" - 1 ;$ h eD t3f1'SC /h eA'17- f 6 8 s9• t4rg 15•5-t) License Search Fj 0 #10 5 jz,oa r.-- ? y7 x?9• 7$ Copies Other ' ? • Total ??(? aDflfl 1 ' . MVoigt & Associates, Inc. ? STRUCTURAL ENG/NEERING SERVICES 4635 NICOLS RD. SU1TE 204 EAGAN, MN 55122 - PH. (651) 686-7727 FAX. (651) 686-8444 Monday, ]uly 02, 2007 Mr. Jon Connelly RE: 559 Caylin Cour[ Dear Mr.7on Connelly: As per your request I have reviewed your plans for the aforementioned project, specifically the garage wall and the bonus room walls. The following is required: • Garage walls: Because of the geometry of the floor plan and the fact that the garages are connected to the main portion of the house, no change to the plan is required and no special nailing or sbeaUting is required. • Bonus room walls: On the rear wall only sheath the wall with 15/32" OSB or plywood and nail to all studs with 8d nails or better at 6" o.c. The information and opinions contained herein aze based upon the limited investigation described at the beginning of this report. No warranties are expressed or implied regarding the existence of other unknown conditions not specifically addressed. Our work is in acwrdance with generally accepted engineering standards and is not intended to be relied upon or transferred to individuals other than the addressee. Should information or conditions become known which di8'er from the diswssion herein, they may alter the opinions or conclusions ofthe undersigned. Please call if you have any questions. Sincerel , , ? Paul W. Voigt, PE Ibgp" OWUfy tlSeL tb]e yain+ BDedftattOn° OP reyomt vvae DreDama bY me or under a?y ftvpC e¢p6TViHfon gnd that I am a duly gg&eu•gd pra{eggtonel Pngneer under i?919Th6 8L8te of Minnesota.. ?..? w. Jt ? ,? 1 L?L Reg. xo. J3070e ! r4 REScheck Software Version 4.0.1 Compliance Certificate Project Title: Jon & Stacy Connolly Report Date: 06/24/07 Data fllename: C:\DoWmeMS and Settings\Other\Side\Connolly\6-22 MS036\MS361 E-Ca1C 6-23.rck Energy Coda: 2000 MlnneaMa Energy Code Locatlon: Scott County, Minnesota Construction Type: Single FBmlly Glazing Area Percentage: 15% Climate Zone: 2 Construction SRe: OwnedAgent: Deslgner/Corrtractor: Lot 14 Block 1 Long Acres 2nd Add. Jon Cannolty 559 Cayln Court Connolly Concepis Eagan, MN 3959 Thames Ave Eagan, MN 55123 651-454-5549 . Ceiling 1: Raised or Energy Truss: 1702 44.0 0.0 37 Wali t: Wopd Frame, 16" o.c.: 642 19.0 0.0 26 Window: 3385-0: Vinyl Frame, Double Pane with Low•E: 93 0.380 31 Window: 7165-0: vnyl Frame, Double Pane with Low-E: 66 0•330 P2 Door: 6•0/6-10-0: alass: 41 0.330 14 Wall 2: Wood Frame, 76" o.c.: 84 19.0 0.0 4 Window: 2947-0b: Vinyl Frame, Double Pane wi[h Low-E: 10 0.330 3 Wall 3: Wood Frame, 16" o.c.: 1674 19.0 0.0 76 Window: 3365-1: Vinyl Frame, Double Pene witli Low-E: 93 0.390 31 Window: 7165-1: Vlnyl Frame, Double Pane with Low-E: 66 0.330 22 Window: 2947-1: Urryl Freme, Double Pane with Low-E: 6 0.330 3 Window: 25654: Virryl Frame, pouble Pane with Low-E: 49 0.330 16 Window: 37657: Virryl Frame, Double Pane with Low-E: 95 0.930 31 Window: 25251: Vinyl Frame, Double Pane with Low-E: 12 0.330 4 Door: 3-0 GIAZE-1: Glass: 20 0.330 7 Door: 3-0 TRANSOM-1: Glass; 3 0.330 1 Doar: 3-0 SOLID-1: Solid: 20 0.071 1 Doa: 2-8 SOLID-1: Solid: 18 0.071 1 Wall 4: Wood Frame, 16" o.c.: 7968 19.0 0.0 107 Window: 3365-2: Ynyl Frame, Double Pane v+uih Low-E: 125 0.330 41 Window: 2347-2: Virryl Frame, Double Pana with Low-E: 16 0.330 5 Window: 2828-2: Vlnryl Frame, Double Pane with Low-E: 14 0.330 5 Wall 5: Siructural Insulated Panals: 432 8.0 51 Basement 1: Sotid Conaete or Masonry: 856 0.0 5.0 69 Weli height: 9.0' Depth below prade: 8.5' Insulation depth: 9.0' Ffoof 1: All-Waod JoisUTruss, Over Uncortditioned 5pace: 483 38.0 0.0 13 Plaw 2: AU-Wood JoisVl'russ, Over Oulside Air: 161 38.0 0.0 4 Fumace i: Forced Hot Air: 92 AFUE Comp7iance Statement: The proposed building daslgn described here is consiatent with the buil ding plans, specifications, and other calculations submitted with the permk epplfcation. The proposed building has been designed to meet the 2000 Minnesola Energy Code requirements in REScheck Version 4.0.1 and to comply with Me mandatory requirements listed in the REScheck Inspection Cheddist Jon 8 Stacy Cannolly Page 1 ot 4 Name - Title Signature Date Jon 8 Stacy Connoily Page 2 of 4 C?(j REScheck Software Version 4.0.1 REScheck Inspection Checklist Date: 06/24107 Pian Review and Inspection Issues This Rst of Items may be helptul tor Plan Reviewers and Building Inspeclors to use as a guide for entordng the Minnesota Energy Code. The Items apply ta Group R, Division 3 Occupanaes, one- and Nro-family residentlal dwellings. The items marked wNh ' appty onty to detached one- and two-tamlty residential dwellings. Plan Review Issues Foundaifon Inspectlon: ? Foundation wall insulahon R-5 minimum. ? FoundaNon insulation extends irom top of wall doWn to top ol the footing. ? Exterior foundation inwlation is covered by a protective coating finish- Concrete Slab or Under-Slab Inspection: Ej Slab on g2de perimeter insulation R-5 minimum. ? Slab insuletion eMends from top of slah to design frost line or top of taoting. ? Floors over unheated spaee R-30 minimum. Windowa ! Doors / Skyllghts: ? Average U-value is 0.37 maxlmum for windows and glass doors (excludss foundaiion windows). Q Window U-values consisten[with building plan and REScheckCertlficata. ? WirMow and door areas consisteM wkh building plan and REScheck CertWicate. Mechanieal Ventilation Issues: ? Residential mechanical ventilaUon system proNdes adequate verrtilatlon per code requirements'. 0 Furnace efficiency is consistenl wilh REScheck CeAi6cate or building plan. Ll Protection against excessive depressuriution is installed per code requiremenis`. Envelope Insulatfon for Plan Review: ? Interia basemeM insulalion R-5 minimum ('rf rro exterior insula[ion). ? Geilings with attics Fl-38 minimum or consisteM wkh building plan and RESchedr Certificate. Li Wall framing and insulation level is consistent with building design and RESChedc Certificate. Inspection Issues Concealed Insulation Framing and Sheathing: 0 Wind wash bamei installad at attic edge. Li Exterior wall comers hamed so that insulatlon can be installed aiter exterior sheaMing is installed. 0 Intersectbns of inierior partition walls and eMerior walls Iramed so that insulalion can he (nstalled batween the partkion and eMenor sheathing after exterlor sheathing is installed. L] Gaps between traming less than one-halt inch are eiiminated by securing framing together or are insulated at ihe 8me of assemMy Li All panetrations 6etween conditionad and uncond'Ripned spaces made prior to framing inspection are sealed'. Intertor Alr Barrier: Jon & Stacy Connolly Page 3 M 4 L) Ali tire stops are air seeled. U Pipes, ducts, wires, aqulpment and flues and chimneys through the intarior air bartier are sealed. El A sealed corrtinuous inteiior air banier is installed on the warm side ot the building emrelope at ceilings, walls, and flaor rim joist areas •. Ll Alr herrier behind tub and ahower Is sealed and protected. L) Recessed IigM fixnures are sealed. Envelope Insulatlon: L] Basemern insulation R-5 minimum. Ll Wind wash baMer on wall separatlng house arM garage is sealed. Q Loose fill insulaNon Is prevented from enlering ihe eavea. Lj InsulaUon on akylight shafts and walls exposed in aWcs is supporled an tne unCOnditfoned side. Attic Insulatlon: Li Attic access panel insulated to R38 tor ceiling panel and F-19 for wall panel. U AtGc cerd attached to framing near access opening. Li NMficffiion oi atlie R-value and date of inslallation posted near building permit inspectlon card. This is a summary only. Other requlremeMS mey apply. See ttie Minnasota Energy Code. Questions7 Call the Department of Public Servlce Intormation CeMer at 651-29E5175 or 1-800-657-3710. Jon 8 Stecy Connolly Page 4 of 4 . m rn c ? r U Ya ? Oz ¢ ?1 ? ? .? ? ? ,0 ? 0 Ja ? ? ? ? ? ,Jd' ? ? ,a o ? Ja? 0 ,C7 ? 0 'z ? O .s ? ? ,Qy? ? .? LOT SURVEY CHECKLIST FOR RESIDENTIAL BUILDING PERMfT APPLICATION . I , - 1Nd I PROPERTY LEGAL: IIzT 't 1 r-- r'" ? '' DATE O SURVEY: k 8/0_7 LATEST REVISION: DOCUMENT STANDARDS . Registered Land Surveyor signature and company • Building Permit Applicant . Legal description • Address . North arrow and scale • House type (rambler, walkout, split wlo, split entry, lookout, etc.) . Diredional drainage arrows with slope/gradient % . Proposed/ex(isting sewer and water services & invert elevation • Street name . Driveway (grade & width - in R/W and back of curb, 22' max.) • Lot Square Footage • Lot Coverage -7p% /4-,y,, Cnj)efJ L . ELEVATIONS Existin g ? ? . Property comers ,g ? ? . Top of curb at the driveway and property line extensions 2 ? ? . Elevations of any existing adjacent homes . ,g ? ? . Adequate footing depth of structures due to adjacent utility trenches ? 'z p . Waterways (pond, stream, etc.) Prooosed 'z ? ? . Garage floor ,z p ? . Basement floor 0 ? ? • Lowest exposed elevation (walkouUwindow) ,B p p . Property comers 'z p ? . Front and rear of home at the foundation PONDING AREA (if applicable) 0 Z p • Easement line p g ? . NWL ? 0 ? • HWL ? A ? . Pond # designation 0 J? 0 • Emergency Overflow Elevation p ? ? . Pond/Wetland buffer delineation y ? . Shoreland Zoning Overlay District y ? • Conservation Easements DIMENSIONS ,Z ? ? • Lot lines/Bearings & dimensions ,g ? ? . Right-of-way and street width (to back of curb) overhangs greater than 2', porches, etc. osed decks i ? ? ? . , ng any prop Proposed home dimensions includ (i.e. all structures requiring pertnanent footings) g ? ? . Show all easements of record and any City utilities within those easements , ,g p p • Setbacks of proposed structure and yard setback of adjacent existing structures ,?y ? ? . Retaining wall requirements: Date Reviewed By: G:lFORMSBU ilding Permd Appliration Rev 11-26-04 ? Surveyor's Certificate SURVEY FOR : ion & Stocy Connolly DESCRIBED AS :Lot ,a, elock i, LONG ACRES 2ND ADOITION, City of Eogan, Dakoto County, and reserving easements of record. I s:9 modmm swpw or Fietaining WalllAflC Be Required -A 956.5 955.9 1 C - P "i 955.9 5'06' 955.7 ' 85.53 E - _ - - "_ -- -? r _-------- c .?---i, 964.2? 965.5 E 9_54 ) 986.4 967.7 3 ? - 15.00 ?n - - - Y' o .. ??? 967.2 F ,,,•.,,?„ L : f-1 G!S-?4EC - wi?' r) r: = ,P1.'.` 437G •i;'? _ ,%ti.' „ •.co; 966.7 A J w z F ? ?z? Q ao? ? F w ? w rA a0? oaH y F Ia,z? I PraPosed `?9 ? I w 2-StorY Garage i " 9'Pcw w/o o I? Ol ? °0 970.3 N ? u o 11,83 .00 O 6 6 N6.ODk?n a 20'17 ° I( ? . ?. ? . n nnol-I014.00 -_ -? - 11 a17 / A 1 L V ? / i ----------- s 89°40'29"E 43.36 J "CAYLIN COURT 559 LOT SQ. FOOTAGE = 12,076 HSE. SQ. FOOTAGE = 2,474 LOT COVERAGE = 201'o PROPOSED ELEVATIONS Top of Foundation = 974,8 Garage Floor = 974.4 Basement Floor = 966.1 Aprox. Sewer Service = 960.4 Proposed Elev. - 0 Existing Elev. Drainage Directions = - Denotes Offset Stoke = . HEDLvNo PLANNlNG ENGlN6BRlNG SVR {'d'YLNC 2005 Pin Oak Drive Eagan, MN 55122 Phone: (651) 405-6600 Fax: (651) 405-6606 SCALE: 1 inch - 30 faet --; ._? ? 966.3 p r-- o ' ? W ? Q1 Ex'ist. Home a ? o GF= 975.1 ?I aw y I? Q? ? 2L303OOM r (OQ 5OD cn) ? ? ? nnn L??I o? m o BENCHMARK, MIN. SETBACK REQUIREMENTS Front -30 House Side -10 Rear -15 Garage Side-5 I HEREBY CERTIFY THAT TFIIS IS A TRUE AND CDRRECT REPRESENTATION OF THE BWNDARIES OF 7HE ABOVE DESCRIBED PROPERtt AS SURVEYED BY ME OR UNDER !AY DIRECT SUPERVISION ANO DOES NOT PURPORT TO SHOW IMPROVEAIENTS DR ENCROACHMENTS, EXCEPT AS SHOWN. oaTE _Z/-U-47 `-d??t'"?F-`? • ?7Z??""? D. LINDGREN, LASURVEY ?A LICENSE NU ER 14376 N0: 07R-226 BOOK FILE Manley-07