Loading...
3967 Donegal WayAddress 3967 DONEGAL WAY Zip 5512 3 Lot 3 Blk i Sub r TRlY FAIN THESE ITEMS WERE / WERE NOT COMPLETE AT THE TIME OF THE FINAL INSPECTION. Date: (a C/ Yes No Inspector: Final grade (6 from siding) Permanent steps (garage) Permanent steps (main entry) Permanent driveway Permanent gas Sod/Seeded grass Trail/curb damage Porch Basement finish Deck Please verify with the builder the rem4al of roof test caps from the plumbing system and the shut-off of water supply to the outside lawn faucet before freeze potential exists. Contact engineering division at 681-4645 before working in rightof-way, or installing underground sprinkler system. White - City Copy Yellow - Resident Copy Pink - Contractor Copy This Certificate issued pursuant to the requirements of the Uniform Building Code certifying that at the time of issuance this structure was in compliance with the various ordinances of the City regulating building construction or use. For the following: UsC a=ifiCati(M- SF T= Bldg- Permit No. 14977 Occulwncy Type R9/ U I Zoning District R1 Type Conu. Owner of Building SMTNWANn El DR$ Address .\\ Building Address 3%7 DCNE=. WAY Ldcality T RI HNM PARK Daze- ' Building Official e+ ?? A CONSPICUOUS PLACE N CITY OF EAGAN 3830 Pilot Knob Road Eagan, Minnesota 55122-1897 (651) 681-4675 SITE ADDRESS: c l'11 I, n l I.i F1 .'li i rl i . I1 PERMIT SUBTYPE: PERMIT TYPE: Permit Number: Date Issued: fit ill v , APPLICANT: r r, i s s:'1 1 v, .1 , TYPE OF WORK: till 1 1 11 1 N1-, I .' / i t /gill INSPECTION TYPE .DATE INSPTA. INSPECTION TYPE DATE INSPTR. I'o;t?i l rte, i ;1„ I N kI VItI-II li BY WAYNI' MI I I f Ii W [;I II llif k I M" -.1 AM 1.1 11MH 1 41, I'111)NU #t.ii I 4'c-),7 Permit Holder Date Telephone i SEWER/ WATER PLUMBING HVAC Inspection Date Insp. Comments FOOTINGS FOUND 7A? 44 FRAMING ROOFING ROUGH PLUMBING PLBG AIR TEST ROUGH HEATING GAS SVC TEST INSUL GYP BOARD FIREPLACE FIREPLACE AIR TEST FINAL PLBG FINAL HTG ORSAT TEST BLDG FINAL DOMESTIC METER IRRIGATION METER FLUSH MAINS CONDUCTIVITY TEST HYDROSTATIC TEST BSMT R.I. BSMT FINAL DECK FTG DECK FINAL ?* 935 RESIDENTIAL BUILDING PERMIT APPLICATION CITY OF EAGAN 3830 PILOT KNOB RD - 55122 651-681-4675 New construction Requirements • 3 registered site surveys showing sq. fl. of lot, sq. ft of house; anchll roofed areas (20% maximum lot coverage albwed) • 2 copies of plan showing beam It window sizes; poured found design, etc.) • 1 set of Energy Calculations • 3 copies of Tree Preservation Plan d lot platted after 711193 • Rim Joist Detail options selection sheet (bldgs with 3 or less units) DATE aO . 1&9 7? JOB SITE ADDRESS Wl % Z2aat P_ pi IF MULTI-FAMILY BUILDII PROPERTY OWNER TYPE OF WORK APPLICANT 91` ADDRESS 1 PAGER # G, HOW MANY __ a 1 / RemodegReoalr Requirements • 2 copies of plan • t set of Energy Calculations for heated additions • 1 site survey for exterior additions & decks • Indicated home served by septic system for additions VALUNION ?9,?(1?'J Q J FIREPLACE(S) -0 1`11 -2 PHONE# 955 7-e?V-Q ? Adv/ZIPCODE 33 CELL PHONE # FAX # NIEW RESIDENTIAL BUILDING ONLY- FILL OUT COMPLETELY Energy Code Category _ MINNESOTA RIILES 7670 CATEGORY I (check one) - Residential Ventilation Category 1 Worksheet S n 1-,1 - Energy Envelope Calculations Submitted D `I II MINNESOTA RULES 7672 FE B 1 1 70 02 New Energy Code Worksheet Submitted Plumbing Contractor: Plumbing System Includes: Water Softener Water Heater No. of Baths _ Phone #: Lawn Sprinkler No. of R.I. Laths Mechanical Contractor: FireSilo L-voloc Mechanical System Includes: _ Air Conditioning Heat Recovery System Sewer/Water Contractor: Fee: $90.00 Phone # 95P-h"--0 7,5-A Fee: $70.00 Phone # All above information must be submitted prior to processing of application. I hereby acknowledge that I have read this application, state that the information is correct, and agree to comply with all applicable State of Minnesota Statutes and City of Eagan OrPaid ''nces. ///? Signature of Applicant /i/ ? •??? Certificates of Survey Received _ Tree Preservation Plan Received _ i7ot Required _ Updated 2002 OFFICE USE ONLY ? 01 Foundation ? 07 05-plex ? 13 16-plex ? 20 Pool ? 30 Accessory Bldg ? 02 SF Dwelling ? 08 06-plex ? 16 Fireplace ? 21 Porch (3-sea.) ? 31 Ext. Alt- Multi ? 03 01 of- plex ? 09 07-plex ? 17 Garage ? 22 Porch/Addn. (4-sea.) ? 33 Ext. Alt - SF ? 04 02-plex ? 10 08-plex ? 18 Deck ? 23 Porch (screened) ? 36 Multi ? 05 03-plex ? 11 10-plex ? 19 Lower Level ? 24 Storm Damage ? 06 04-plex ? 12 12-plex Plbg_Y or_ N ? 25 Miscellaneous ? 31 New ? 35 Int Improvement ? 38 Demolish (Interior) ? 44 Siding ? 32 Addition ? 36 Move Bldg. ? 42 Demolish (Foundation) ? 45 Fire Repair ? 33 Alteration ? 37 Demolish (Bldg)' ? 43 Reroof ? 46 Windows/Doors ? 34 Replacement 'Demolition (Entire Bldg only) - Give PCA handout to applicant Valuation Occupancy MC/ES System Census Code Zoning City Water SAC Units Stories Booster Pump Nbr. of Units Sq. Ft. PRV Nbr. of Bldgs Length Fire Sprinklered Type of Const Width REQUIRED INSPECTIONS - Footings (new bldg) Final/C.O. Footings (deck) _ Final/No C.O. Footings (addition) _ Plumbing Foundation _ HVAC _ Drain Tile Other Roof - Ice & Water _ Final _ Pool _ Ftgs _ Air/Gas Tests _ Final _ Framing - Siding _ Stucco _ Stone Fireplace _ R.I. _ Air Test - Final Windows (new/replacement) Insulation - - Retaining Wall Approved By Base Fee Surcharge Plan Review MC/ES SAC City SAC Water Supply & Storage S&W Permit & Surcharge Treatment Plant Plumbing Permit Mechanical Permit License Search Copies Other Total Building Inspector PERMIT CITY OF EAGAN 3830 Pilot Knob Road Eagan,, Ainnesota 55122-1897 (651) 681-4675 PERMIT TYPE: BUILDING Permit Number: 034 27 2 Date Issued: J. 2 / 3 1. / 9 8 SITE ADDRESS: P.I.N.: 10-49500-030-01 DESCRIPTION: 3 9E7 17DNEG(jI. WAY LOT: 3 BLOCK: 1 MURPHY FARM 3u11 din4'_.PP..r'mi.t I y p e Lluilding Work Type :`U8C Occupancy Con"Lr-UCti.on Tv"Cae i ? ?oninq Buildinq Length Suildinq Width Suildinq stories Square Feet Census. Code SF DWG NEW R-3..U-1 VN R--7. 6 s1 2.078 10:1 1 - FAM. 0EIACFt REMARKS: PLAN REVILWED 8''! Wf)YNE ,M1?L1LR, S & W PtllIYlt R 1, HE''.31A/d PLLIIh7.i'II F'HDNF. 14681-8252. FEE SUMMARY- Base Fee Plan Review Surcharge SAC SAC % SAC Units Subtotal VALLIAI-10N $96.00 $7. ,.0N49. 00 1.00 1;3..318.96 1.192.000 MISC. F`"rS Total Fee _:,$1,',;92.._50 $4,911.46 CONTRACTOR: A I),f) ] - ST . I.. I (. OWNER: STEINWAND BLDRS INC 19855111 0001056 TEINWAND BUILDERS 2 050 PILLSBURY AV£ 23050 PILLSBURY AVF CAKEVlLL1-: MN 1;;5044 LAKEVILLE NN 55044 .(612) 894-0498 (612)985-51.11 t I hereby acknowledge that I have read this application and state that the information is correct and agree to comply with all applicable St.at:e of Nn. Statutes and City of Eaq?;n Ordinances- r ? APPLICANT/PERMITEE SIGNAT ISSUED BY. IGNAT .r. • FYI ? r'_ ? t if .. ( ,i.. Ph1 .. I „?....; ". .q i Y, 1998 BUILDING PERMIT APPLICATION (RESIDENTIAL) CITY OF EAGAN .J? ?I 3830 PILOT RD - 55122 l' I I + 681-4675 New Construction Requirements RemodeVReoair Requirements fo f 3 registered site surveys ? 2 copies of plan ? 2 copies of plans (include beam & window sizes; poured fnd. design; etc.) ? 2 site surveys (exterior additions & decks) ? 1 energy calculations ? t energy calculations for heated additions ? 3 copies of tree preservation plan if lot platted after VIM required: _ Yes _ No DATE:_ November 11. 1998 CONSTRUCTION COST; 280,000.00 DESCRIPTION OF WORK: New Construction - Single Family Dwelling STREET ADDRESS: k-k- )( d ry-\ LOT: 3 BLOCK: 1 SUBD./P.I.D. #: -3-0 49590 039 01 Name: Steinwand Builders, Inc. Phone#: 612/985-5111 PROPERTY Last First OWNER Street Address: City Company: St CONTRACTOR Street Address: City 23050 Pillsbury Avenue Lakeville State: MN Zip: 55044 einwand Builders, Inc. Phone #: 612/985-5111 23050 Pillsbury Avenue License# 1055 Lakeville State: MN Zip: 55044 ARCHITECT/ ENGINEER Company: Feehan Residential Architecture Phone#: 612/494-3224 Thomas Feehan Registration #: Street Address: 20415 County Road 50 City Corcoran State: MN Zip: 55340 Sewer & water licensed plumber (new construction only): Hessian Plumbing S erv .. Penalty applies when address chang and lot change is requested once permit is issued. (o-6 I -gaS-'.)- I hereby acknowledge that I have read this application and state that the information is correct and agree to comply with all applicabl State of Minnesota Statutes and City of Eagan Ordinances. SteinLaAn4 5ttilders , 14. Signature of Applicant: OFFICE USE ONLY Certificates of Survey Received ti' Yes No G i? LY7_VI S _ h, i Ni V L 3 Tree Preservation Plan Received - Yes - No ? Not Required OFFICE USE ONLY BUILDING PERMIT TYPE ? 01 Foundation ? 06 Duplex ? 11 Apt./Lodging Zf 02 SF Dwelling ? 07 4-plex ? 12 Multi Repair/Rem. ? 03 SF Addition ? 08 8-plex ? 13 Garage/Accessory ? 04 SF Porch ? 09 12-plex ? 14 Fireplace ? 05 SF Misc. ? 10 _-plex ? 15 Deck WORK TYPE 161 New ? 33 Alterations ? 36 Move ? 32 Addition ? 34 Repair ? 37. Demolition GENERAL INFORMATION Const. (Actual) (Allowable) UBC Occupancy Zoning # of Stories Length Depth APPROVALS Planning Basement sq. ft. Main level sq. ft. R31/1 2 11 ?W sq. M ft. - sq. pones A ft. r40- sq. ft. sq, ft. Footprint sq. ft. / /-/ /9 /H/9 I y/9 ? y2 3'9 ?0 7.71 Building Engineering Variance Permit Fee ?• a5 Valuation: $ GI GNJ Surcharge (o .O QlSa mcnt Plan Review S 7? • ?1 I 36 )e lay= 501 License iabx 96 = 1 Ah97 MC/WSSAC 1bUU.U 306 ,o = 3ao,?ti l City SAC $ ,rX v q X X ti _ Water Conn. io x /00 t Water Meter - SO sy/o x Ldp ?`ri9 /? x Acct. Deposit S/W Permit ?s?rn? E,vs sns€°/y/9,1z y 5N = 7E63 a, ?g S/W Surcharge Treatment PI. LPN 7663 a,H? G Park Ded. s,q /tom=l Hl%l3 X 5 v = Trails Ded. Other d N ? 5 Copies z /a ° /a xI v j 6= a Total: '-I a I Io 7b z y = 30 3H? xe20= 61041) %SAC r3RR <l= 65g, 7s x/6 3 k al 05`f0 SAC Units ? 16 Basement Finish ? 17 Swim Pool ? 20 Public Facility ? 21 Miscellaneous MC/WS System City Water Fire Sprinklered PRV Booster Pump Census Code. SAC Code Census Bldg Census Unit Sheetl EXTERIOR ENVELOPE AVERAGE "U" COMPUTATION SITE ADDRESS OWNER PLAN NO. 9-1015-8 CONTAACTOR STEINUTAND BUILDERS INC DATE OCT. 19.1998 DETERMINE WORKING SQUARE FOOTAGE 1. Total exposed wall area 4002.25 sq. ft. x.11 = 440.2475 2. Total roof / ceiling area 1364 sq. ft. x.026 = 35.464 3. Total floor cant. area 0 sq. Ft. x.026 = 0 (over unheated enclosed areas) 4. Total floor cant. area 21 sq. Ft x.08 = 1.68 (over unheated exposed areas) 5. Total exposed wall area above the floor- -------------------------------- 3631.42 a. Total wall window area ............................. ................ 336.8274 b. Total door area ................................... ................ 37.8189 c. Total sliding glass door area ......................... ................ 84.4422 d. Total fireplace area ................................ ................ 0 e. Total wall framing area ave. 10% 363.142 F. Total net wall area above the floor .................... ................ 2809.19 g. Total rim joist area... ............................. ................ 338 TOTAL EXPOSED FOUNDATION AREA ................................. 32.83 h. Total foundation window area ....................................... 0 i. Total net foundation area ........................................... 32.83 Determine "U" value of each wall segment. 0. 336.8274 x "U" 0.39 = 131.3627 b. 37.8189 x "U" 0.06 = 2.269134 C. 84.4422 x "U" 0.39 = 32.93246 d. 0 x "U" 0 = 0 e. 363.142 x "U" 0.090334 = 32.80416 F. 2809.19 x "U" D.043215 = 121.3997 9. 338 x "U" 0.040683 = 13.75102 h. 0 x "U" 0.39 = 0 1. 32.83 x "U" 0.076161 = 2.500381 6 .......................................Total: 337.0196 If item #6 is the some as or less than item #1 you have met the current energy codes. 2 MCRR 1.16008 R AND O. Page 1 Sheetl TOTAL EXPOSED ROOF/CEILING AREA-------------------------- 1364 j. Total skylight area ..................... ........................ 0 k. Total flat roof / ceiling framing area .................................. 136.4 1. Total net flat roof / ceiling area ...................................... 1227.6 Determine "U" value for each roof / ceiling segment j. 0 x "U" 0 = 0 k. 136.4 x "U" 0.026925 = 3.67259 1. 1227.6 x "U" 0.022795 = 27.98268 7... .......................................... Total: 31.65527 If item #7 is the some as or less than item #2 you have met the energy code. 2 MCRR 1.16008 R AND O. TOTAL FLOOR CANT. FIRER (enclosed) -------------------------- 0 o. Total floor cont. framing area (avg. 10%) ............................... 0 p. Total net insulated floor / cont. area .................................. 0 Determine "U" value for each floor / cant. segment o. 0 x "U" 0.064144 = 0 P. 0 x "U" 0.029386 = 0 8 ...............................................Total: If item #8 is the some as or less than item #3 you have met the energy code. 2 MCRR 1.16008 R AND O. TOTAL FLOOR CANT. AREA(exposed) -------------------------- 21 Total floor cant. framing area (avg. 10%) .............................. 2.1 r. Total net insulated floor / cont. area ................................... 18.9 Determine "U" value for each floor / cant. segment q. 2.1 x "U" 0.027816 = 0.058414 r. 18.9 x "U" 0.027894 = 0.527197 9.... .......................................... Total: 0.585611 If item #9 is the same as or less than item #4 you have met the energy code 2 MCRR 1.1608 A AND O. I HEREBY CY THR HAVE' REGULATED THE "U" FACTORS AND "R" VALUES HEREIN AND THAT THE BUILDING HERE DESC MEE OR E DS THE STATE OF MINNESOTA ENERGY CONSERVATION ACT. IC")9 - IPA (DATE) Page 2 Sheetl DETERMINE "U" VALUES THROUGH STUD WITH SIDING SHEET ROCK Interior air 0.68 Sheet Rock 0.45 Thermo-Break 0 Stud 6.93 Sheathing 2.06 Siding 0.78 Exterior Air 0.17 Total "A" 11.07 1/A = "U" 0.090334 THROUGH INSULATION WITH SIDING 6 SHEET ROCK Interior Air 0.68 Sheet Rock 0.45 Thermo Break 0 Insulation 19 Sheathing 2.06 Siding 0.78 Exterior Air 0.17 Total "R" 23.14 1 /R = "U" 0.043215 THROUGH CEILING MEMBER Interior Air 0.68 Sheet Rock 0.58 Ceiling Member 4.35 Insulation 30.92 Still Air 0.61 Total "A" 37.14 1 /A = "U" 0.026925 THROUGH CEILING INSULATION Interior Air 0.68 Sheet Rock 0.58 Insulation 42 Still Air 0.61 Total "R" 43.87 1 /A = "U" 0.022795 Page 19 Sheetl THROUGH CONCRETE BLOCK Interior Air 0.68 Concrete Block 1.28 Insulation 1 1 Sheet Rock (opt.) 0 Exterior Air 0.17 Total "R" 13.13 1 /A = "U" 0.076161 THROUGH RIM JOIST Interior Air 0.68 Insulation 19 Rim Joist 1.89 Sheathing 2.06 Siding 0.76 Exterior Air 0.17 Total "A" 24.58 1 /R = "U" 0.040683 "U" value for window 0.39 "U" value for doors 0.06 "U" value for Patio Drs. 0.39 THROUGH CANT. @ MEMBER (enclosed) Interior Air 0.68 Finish Flooring 1.23 Underlayment 0 Plywood 0.93 Joist 11.56 Sheet Rock 0.58 Still Air 0.61 Total "R" 15.59 I /R = "U" 0.064144 THROUGH CAM. @ INSULATION (enclosed) Interior Air 0.68 Finish Flooring 1.23 Underloyment 0 Page 20 Sheetl Plywood 0.93 Insulation 30 Sheet Rock 0.58 Still Air 0.61 Total "A" 34.03 1 /R = "U" 0.029386 THAOUGH CANT. @ MEMBER (exposed) Interior Air 0.68 Finish Flooring 1.23 Underloyment 0 Plywood 0.93 Joist 11.56 Sheathing 20.6 Soffit 0.78 Exterior Air 0.17 Total "A" 35.95 1119 = "U" 0.027816 THROUGH CANT. @ INSULATION (exposed) Interior Air 0.68 Finish Floor 1.23 Underlayment 0 Plywood 0.93 Insulation 30 Sheathing 2.06 Soffit 0.78 Exterior Air 0.17 Total 'R" 35.85 1/R = "U" 0.027894 Page 21 LOT SURVEY CHECKLIST FOR RESIDENTIAL BUILDING P MIT APPLICATIO PROPERTY LEGAL: ATE OF O 3 w LATEST REVISION: z/ / q4 DOCUMENT STANDARDS U 0 7 >j F ? • Registered Land Surveyor signature and company ? Building Permit Applicant ? ? • Legal description m' ? ? • Address ?r ? ? • North arrow and scale ? • House type (rambler, walkout, split w/o, split entry, lookout, etc.) 9 ? • Directional drainage arrows with slope/gradient % O • Proposed/existing sewer and water services & invert elevation ? Street name ? • Driveway ELEVATIONS Existina ?/ ?? • Sewer service (or Proposed) M O ? Property corners GK?M ? Top of curb at the driveway ? W?-O • Elevations of any existing adjacent homes Proposed ?? ? Garage floor L9' ? • First floor O ? • Lowest exposed elevation (walkoutWndow) M-"10 ? Property corners ®?'O ? • Front and rear of home at the foundation PONDINGPONDING AREA (if apOicable) ? a8'? Easement line ? 0'-'O • NWL ? B -'O • HWL ? O • Pond # designation ? .IY ? Emergency Overflow Elevation DIMENSIONS tti? ? • Lot lines/Bearings & dimensions ?? ? Right-of-way and street width (to back of curb) Q? ? Proposed home dimensions including any proposed decks, overhangs greater than 2', porches, etc. (i.e. all structures requiring permanent footings) ? • Show all easements of record and any City utilities within those easements ?'p • Setbacks of proposed structure and sideyard setback of adjacent existing structures ? t9' ? Retaining wall requirementsjany Reviewed: January 1996 CRAIG19Mf8LDG PRMT. FM 1999 BUILDING PERMIT APPLICATION (RESIDENTIAL) RD - O CITY OF EAGAN 3830 PILOT KNOB B RD 55122 3 I (651) 681-4675 New Construction Requirements ? 3 registered site surveys ? 2 copies of plans (include beam & window sizes; poured fnd. design; etc.) ? 1 energy calculations ? 3 copies of tree preservation plan if lot platted after 7/1/93 required: _Yes - No DATE: June 3. 1999 DESCRIPTION OF WORK: STREETADDRESS: 3967 Done Remodel/Repair Requirements A o'?? ? 2 copies of plan ? 1 site surveys (exterior additions & decks) ? 1 energy calculations for heated additions CONSTRUCTION COST; 1500.00 `( "w?,? Vl,t Ci V f LOT: 3 BLOCK: 1 SUBDJP.I.D.# 5Qr11 ) N;une: Steinwand Builders-, Inc. Phone#: 612[°225111___----- -__ PROPERTY Lut rUsL OWNER Street Address: 23050 Pillsbury Avenue City ______ Lakeville -------- State: CONTR.ICTOR ARCHITECT/ ENGINEER zip: __5SQ4_4___ -- Cot„p;n,y,_-Steinwand Builders, Inc. Phone#: 612(985=5111 _ - Street Address:__ 23050 Pillsbury Avenue License # _jQ5.5_-__ExP. "_ / ;1 M0 Cite Lakeville ---- -- State: _ 11N -......... zip: _55044 -___-- Company: r/A -- Name:_-____- Street Address: City - Sewer & water licensed plumber (new construction only): _ change and lot change is requested once permit is issued. Phone #: ____--- --------- Registration #: --- - - ------ - ---- State: --- Zip: I hereby acknowledge that I have read this application, state that the infor State of Minnesota Statutes and City of Eagan Ordinances. S I Signature of Applicant: OFFICE USE ONLY Certificates of Survey Received Yes No Tree Preservation Plan Received Yes No Penalty applies when address and ree to comply with all applicable s Inc. W d, Pres RECEIVED Not Required JUN 0 8 1999 BY:? OFFICE USE ONLY BUILDING PERMIT TYPE ? 01 Foundation ? 06 Duplex ? 02 SF Dwelling ? 07 4-plex ? 03 SF Addition ? 08 8-plex ? 04 SF Porch ? 09 12-plex ? 05 SF Misc. ? 10 = plex ? 11 Apt./Lodging ? ? 12 Multi Repair/Rem. ? ? 13 Garage/Accessory ? ? 14 Fireplace ? 15 Deck 16 Basement Finish 17 Swim Pool 20 Public Facility 21 Miscellaneous WORK TYPE ?k31 New ? 33 Alterations ? 32 Addition ? 34 Repair GENERAL INFORMATION ? 36 Move ? 37 Demolition Const. (Actual) Basement sq. ft. Census Code y (Allowable) Main level sq. ft. SAC Code U UBC Occupancy sq. ft. Census Units U Zoning sq. ft. Census Bldg # of Stories sq. ft. MC/WS System Length sq. ft. City Water Width Footprint sq. ft. Booster Pump PRV Fire Sprinklered APPROVALS Planning Building IM Engineering Variance Permit Fee Valuation: $ >2C%(7 Surcharge ---__ .° Plan Review License " :r,a r r;Tt 8 MC/WS SAC Ci a/c, r = 1. ° , City SAC Water Conn. Water Meter Acct. Deposit ,nt I -E, I r701?, _G'tl... L, 6r?.,rr7 S/W Permit 2:."B 90[t:i. ^9r--, nni:.;„q' ;pY 50 S/W Surcharge Treatment PI. Park Ded. Trails Ded. Other Copies Total: i , % SAC CR : 1.!:»2. Z: SAC Units _:= [r'.. !ra 'C:Y i 1999 BUILDING PERMIT APPLICATION (RESIDENTIAL) CITY OF EAGAN ??S Y 3830 PILOT KNOB RD - 55122 (651) 681-4675 v ? New Construction Requirements Remodel/Repair Requirements 70 ? 3 registered site surveys ? 2 copies of plan ? 2 copies of plans (include beam & window sizes: poured fnd. design; etc.) ? 1 site surveys (exterior additions & decks) ?J ? 1 energy calculations ? 1 energy calculations for heated additions 'S/ ';k' 1,0 # 3 copies of tree preservation plan if lot platted after 7/1193 required: _ Yes - No DATE: May 14th, 1999 DESCRIPTION OF WORK: Finish CONSTRUCTION COST; $2000.00 STREET ADDRESS: 3967 Donegal Way LOT: 3 BLOCK: 1 SUBD./P.I.D. #: 6 588-938-91- t fyV&"G'6' A--7a f PROPERTY ( ) WIN ER C O NTRACCOR ARCHITECT/ ENGIA EER 'Nan=Steeiinwand Builders, Inc. Pltoiic#: -612/985-5111------- last ------ Firs[ -- street Address:__23050_ Pillsbury-Avenue ----------------------------------------- City ....... -Lakeville ---------------- State: NIN ------- Lip: - _-5-5S2L4 ----- Conipuiv:_ Steinwand Builders, _Inc. Pttone #: __6121$5-_511.1----- ---- Street Address:-23050 Pillsbury Avenue _-_ --__- Licettse# _105.__-Esp. -31-311200 City ---------Lakeville---------------- State: __--rIrL-- - Zip: ---- 55.0-44----- -- Street City N/A --------- Phone #: -------- -------- Registration #: ---- -------------- State: ------------------ Zip: Sewer & water licensed plumber (new construction only): K N/A change and lot change is requested once permit is issued. Penalty applies when address I hereby acknowledge that I have read this application, state that the information is correct, and agree to comply with all applicable State of Minnesota Statutes and City of Eagan Ordinances. Ste3?. yTan Builders, Inc. Signature of Applicant: bv?7l? a. Pres . i OFFICE USE ONLY Certificates of Survey Received - Yes No Tree Preservation Plan Received Yes No Not Required 2 4 OFFICE USE ONLY BUILDING PERMIT TYPE ? 01 Foundation ? 06 Duplex ? 02 SF Dwelling ? 07 4-plex ? 03 SF Addition ? 08 8-plex ? 04 SF Porch ? 09 12-plex ? 05 SF Misc. ? 10 = plex WORK TYPE ? 31 New 33 Alterations ? 32 Addition 34 Repair GENERAL INFORMATION ? 11 Apt./Lodging ? 16 Basement Finish ? 12 Multi Repair/Rem. ? 17 Swim Pool ? 13 Garage/Accessory ? 20 Public Facility ? 14 Fireplace Or 21 Miscellaneous ? 15 Deck ? 36 Move ? 37 Demolition Const. (Actual) Basement sq. ft. (Allowable) Main level sq. ft. UBC Occupancy sq. ft. Zoning sq. ft. # of Stories sq. ft. Length sq. ft. Width Footprint sq. ft. APPROVALS Planning Building Census Code SAC Code Census Units O Census Bldg MC/WS System City Water Booster Pump PRV Fire Sprinklered Engineering Variance Permit Fee Surcharge Plan Review License MC/WS SAC City SAC Water Conn. Water Meter Acct. Deposit S/W Permit S/W Surcharge Treatment PI. Park Ded. Trails Ded. Other Copies Total: % SAC SAC Units Valuation: $ 2 ?NC k I.,_.iI':i Tii9 i' d:i;.- ''.-. ^ CITY USE ONLY LOT =M BL RECEIPT #: ?/ SUBDe! ' .?U? r / tIti`. RECEIPT DATE: /a3/ 9 9 0' 1 MECHANICAL PERMIT # I5 V A Q ? 1999 MECHANICAL PERMIT (RESIDENTIAL) CITY OF EAGAN 3630 PILOT KNOB RD EAGAN MN 5518E / ??? Date: (651) 681-4675 Complete ±his section WL if you are installing ??VAC in a single fare ly dwelling, townhome or condo under construction and not owner /occupied. • HVAC: 0-100 M B T U ADDITIONAL 50 M BTU • Gas outlets (minimum of one required @ $3.00 ea.) State Surcharge Total $ 30.00 6.00 3LP' Co .50 $ ,5 Complete this section only if you are remodeling, adding to, or repairing an existing single family dwelling, townhome, or condo. Please indicate if it is a new item, alteration, or repair. New _ Alteration _ Repair _ Other Reminder: Call 681-4675 for inspections. - Furnace Air conditioning Air exchanger Other $ 30.00 State Surcharge .50 Minimum Total Due $ 30.50 SITE ADDRESS: OWNER NAME: PHONE #: ?-' (AREA CODE C C?? J INSTALLER NAME: PHONE#: Of - 13 STREET ADDRESS: / 7 O I jho e -SS-Qt?Jd /- UN ' 5. (AREA CODE) CITY: - STATE:YJ fo zip:. 5 3 / IG T F PERM[ L BL SUBD. APPROVED BY: CITY USE ONLY RECEIPT #: RECEIPT DATE: INSPECTOR MECHANICAL PERMIT#: 1999 MECHANICAL PERMIT (COMMERCIAL) EAGAN, MN 55122 Please complete for: all commercial/industrial buildings multi-family buildings when separate permits are not required for each dwelling unit DATE: CONTRACT PRICE: WORK TYPE: NEW CONSTRUCTION INTERIOR IMPROVEMENT DESCRIPTION OF WORK: PHONE #: (AREA CODE) STATE: ZIP: FEES: 1% of contract price OR $30.00 minimum fee, whichever is greater. Processed piping - $30.00 CONTRACT PRICE x I % PROCESSED PIPING PERMIT FEE STATESURCHARGE TOTAL SITE ADDRESS: OWNER NAME: TENANT NAME (IMPROVEMENTS ONLY): INSTALLER: ADDRESS: CITY: ($.50 per $1,000 of permit fee due on all permits.) PHONE #: (AREA CODE) CITY Of EAfiAN 5830 PILOT KNOB RD (651) 681-4675 4g,3?,?jb SIGNATURE OF PERMITTEE L BL 1 CITY USE ONLY SUBD. 1 43T? RECEIPT #: 0 yffo RECEIPT DATE: `5 t? 7 PERMIT# 3r3iJ I 9? 1999 PLUMBING PERMIT (RESIDENTIAL) CITY OF EAGAN 3$30 PILOT KNOB 1tD EAGAN, MN 55122 (651) 691-4695 Please complete for: > single family dwellings > townhomes and condos when permits are required for each unit > backflow preventer for underground sprinkler system FIXTURES EACH # TOTAL Bath tub $ 3.0n x _ $ Floor drain 3.00 x $ Gas piping outlet ` minimum - 1 3.00 x = $ Hot tub/spa 3.00 x = $ Kitchen sink 3.00 x = $ Laundry tray 3.00 x $ Lavatory 3.00 x 14 _ $ 1 Minimum fee alterations to existing dwelling 30.00 x = $ Private Disposal System new/refurbished ' requires MPC tic. 75.00 x = $ Private Disposal System abandonment 30.00 x = $ RPZ new installation/re air 30.00 x = $ Rough opening 1.50 x = $ S o Shower 3.00 x $ Underground srinkler if dwelling is under construction 3.00 x = $ Underground srinkler if existing dwelling 30.00 x = $ Water closet 3.00 x = $ Water heater 3.00 x I = $ Water softener if dwelling under construction 5.00 x = $ Water softener if existing dwelling 30.00 x = $ Water turnaround 30.00 x = $ State Surcharge .50 > > > $ 50 Total --> > > ----> $ 9. so Reminder. Call for inspections of alterations, i.e. water heaters, water softeners, etc. -------- --- ---- • -- --- --- --- - --- I hereby acknowledge that I have reatl this application, state that the information is correct, and agree to comply with all appli-cable City of Eagan ordinances. It is the applicant's responsibility to notify the property owner that the City of Eagan assumes no liability for any damages caused by the City during its normal operational and maintenance activities to the facilities constructed under this permit within City property/right-of-way/easement. SITE ADDRESS: / Co D o n es < 1 OWNER NAME:: p?Q, I anC Q uTl?er? TELEPHONE #: (yla.- 9$S-- )1I (AREA CODE) INSTALLER NAME: is e JJ I an S e r.. I ccs STREET ADDRESS: .ro._ Tl' TELEPHONE#: Cc S l' G ' ) - 8 a S 2 (AREA CODE) L-1- CITY: 1 Cam - /--/ - '7-7 r S S 0 7 "1 STATE: ZIP: SIGNATURE OF PERMITTEE :?? 2000 BUILDING PERMIT APPLICATION (RESIDENTIAL) RD 4 17? CITY OF EAGAN 3830 PILOT KNOB B RD - 55122 651-681-?467(5?(I New Construction Reaulrements ?n 1 I ?1 ? 1 Remodel/Repair Reaulrements lf(1 4 171.76 CA11-41-1$-vo ym 3 registered site surveys slowing sq. ft. of lot, sq. ft. of house p p 2 copies of plan and gL roofed areas (20% maximum lot coverage oilowedl / 1 set of energy calculations for heated additions 2 copies of plans (show boom & window sizes; poured Ind. design; etc.) 1 site survey for exterior additions & decks 1 set of energy calculations 3 copies of tree preservation plan If lot platted after 7/1/93 DATE: CONSTRUCTION COST. DESCRIPTION OF WORK: ?&4fW N , )4);d4_ g If multi-family bldg., how many units? STREET ADDRESS: LOT: V BLOCK: SUBD./P.I.D. C. Name: Avod /?w t®LI' Phone C(p PROPERTY Last Irst OWNER Street Address: , 3 26 -2 a tT Pci e/ City Fa r 0/ State: ?i ll Zip: Company: ( oC) b S 61)(4 ? n Phone #: (o S-Z _727-0669 (area code) CONTRACTOR //'' Street Address: 3 M C) )©C1K TeerC' C-F ' ?1e License # Exp. City UA, 4 6 ear l1P f?!_ State: vu( L/? , Zip: sx?_l/ ARCHITECT/ / ENGINEER Company:s 1(Q?V S ?i? l 2 i Name: / ? ill/1/I f yK ke Telephone #: ((p ??) 2 7 7-06, 6 Street Address: 3 `f 00 Qc ! 7?ydQ C'Q Registration #: City W • 6,L- State: Sewer/water licensed plumber (if installing sewer/waterPhone Zip: I hereby acknowledge that I have read this application, state that the information Is correct, and agree to comply with all applicable State of Minnesota Statutes and City of Eagan Ordinances. Signature of Applicant / OFFICE USE ONLY Certificates of Survey Received - Yes No I JUL i Tree Preservation Plan Received - Yes No Not Required ` OFFICE USE ONLY BUILDING PERMIT SUBTYPES ? 01 Foundation ? 07 05-plex ? 13 16-plex ? 21 Porch (3-sea.) ? 02 SF Dwelling ? 08 06-plex ? 17 Garage ? 22 Porch/Addn. (4-sea.) ? 03 01 of_ plex ? 09 07-piex ? 18 Deck ? 23 Porch (screened) ? 04 02-plex ? 10 08-plex ? 19 Lower Level ? 24 Storm Damage ? 05 03-plex ? 11 10-plex Plbg _Yor_ N ? 25 Miscellaneous ? 06 04-plex ? 12 12-plex 20 Pool ? 30 Accessory Bldg. W9RK TYPE X 31 New ? 36 Move Bldg. ? 43 Reroof ? 32 Addition ? 37 Demolish (Bldg)" ? 44 Siding ? 33 Alteration ? 38 Demolish (Interior) ? 45 Fire Repair ? 34 Repair ? 42 Demolish (Foundation) ? 46 Windows/Doors * Give PCA handout to applicant for demolition permit GENERAL INFORMATION SAC Code 0 1 # of Stories sq. ft. No. of Units o Length 3S sq. ft. No. of Buildings 1 Width 16 Footprint sq. ft. Const. (Actual) Basement sq. ft. Census Code (Allowable) Main level sq. ft. MC/ES System UBC Occupancy sq. ft. City Water Zoning sq. ft. Booster Pump PRV Fire Sprinklered MISCELLANEOUS INSPECTIONS ? Stucco/Stone APPROVALS Planning B uilding Engin eering Variance ? 31 Ext. Aft - Multi ? 33 Ext. Aft - SF ? 36 Mufti Permit Fee Surcharge Plan Review License MC/ES SAC City SAC Water Conn. Water Meter Acct. Deposit S/W Permit S/W Surcharge Treatment PI. Park Ded. Trails Ded. Other Copies Total: Valuation: $ 1000 SAC Units % SAC i't' 6So$S \ \ 101.65 a g 4r ,DONEGAL 9914 z I p ?# A _-?? 1^ COURT 130.( 186.68 S 89 36'14" W N ?I tH ss?ss?\ ` U $ S 8932'. V 30 I / /\ 101.70 o N =` I iO N o ?? a? Iv p mow) °I I° Vj `fir, r!- ,? _ 130 ,j, aN 25 25 - k„ I I = T S 89.32'. C 4 zia ? _ Vat ;p qf IL _ s - \A ^l b / x ;. / AV ? \ i 58_20--- -`- =? 5911 -200.00- yti m `S 89°36'14., W 1 ' ----------- --- LO w m y w /P ?o, ? ? ° U v Pl? U) a ? O CP?'b F cF 10 ?;? is N /? / \'O? m • ?w C2 r# 0000, ?. 5`288.95 86.05 4828 I ` ' ,:? ?6 dry ?-j cJ' 2 223.26 S8903309W 125.44 '30.85- 7eoooo ?,,???' ? ? d=08016'31 R=868.51 Q` "`'--SOUTH LINE OF SW 114 OF NW 114, SW CORNER OF NW 1/4, SEC. 21, TWP. 27, RGE. 23 SEC. 21, TWP. 27, RGE. 23 o (DAKOTA CO. MONUMENT) ?? 1 * * * * PIONEER All, err®-fn e 2422 Enterprise Drive Mendota Heights, MN 55120 (612) 681.-1914 FAX:681-9488 625 Highway 10 N.E. Blaine, MN 55434 (612) 783-1880 FAX:783-1883 Certificate of Survey for: STEINWAND BUILDERS, I&Ay 6-NEGAL WAY EAGAN MN fan 4UG:C400 ?C, ?,..Y• V?LCI TI? 5? rU !%TN9? 5 INC. BENCH 'MARK DONEGAL TOP OF PIPE ELEV,=914.74 . (VACANT) oo 11 97 aC 911 awl SO&1 5 ?F 9oe.7 rt 11 1p 94V 9o9.3> pa / v 0a (C6 L7, Q ST.MH, 901.7 ?y \ l tell 4 \? ? \ SA 908.9 1 3 g5O eta.e \ T ?1 \ / t 4, Qo 11 \ \° 3 Vt ? 911. O 9 ,NI 10.2 J VP sF?yyc ?=? 1 - / ?fia ?yh?a4. Syr 1 1 11 ! i ! i ! i ! i ! I I ! 0 J 89, hj TREATMZNT POND c0i 100 YVHWL.=894.1 ! / I 1 7/D,S again WE 86.05 2 cl (VACANT) WAY-,1 I ! 5 ,9q1NyV. NOT 911.41 tX ACITY r? SERVICE \-BENCH MARK TOP OF PIPE ELEV.=912.23 / g OPQ5ED HOUSE ELEVATION ?? LOWEST FLOOR ELEVATION: 96-7• !>, '?7 BLOCK ELE VA TiON: ?tv TOP OF 9ly8 GARAGE SLAB ELEVATION: X 000.00 DENOTES EXISTING ELEVATION ( 000.00 ) DENOTES PROPOSED ELEVATION - ?. DENOTES CRANAGE AND UTILITY EASEMENT -->~ DENOTES DRAINAGE FLOW DIRECTION . ?DFNOTES M"MENT? pFTt7OTES, 't T' .? y I n A nC ILI?Jr±1' as u"u'. t?tit 131 bl+ NOTE: PROPOSED GRADES SHOWN PER-GRADMN PLAN'SY-BRW AND NOTE= OP STRUCTURES DIMENSIONS ONLY. SHE ARCH ECYUALRPLANSA FOR BUILDINCAAND CATION FOUNDATION DIMENSIONS. NOTE: NO SPECIFIC TH?I SUITABILITY OF SOILS S 10 1 SUPPORTL THE SPECIFIC MOUSEY THE ON THIS LOT PROPOSED 15 N07 THE RESPONSIBILITY OF THE SURVEYOR. NOTE: THOSE SHOWN ON THE RECORDED PLAT. TO SHOW EASEMENTS OTHER THAN B. NOTE: CONTRACTOR MUST VERIFY DRIVEWAY DESIGN. NOTE: BEARINGS SHOWN ARE BASED ON AN ASSUMED DATUM WE HEREBY CERTIFY TO STEINWAND BUILDERS, INC. THAT THIS IS A TRUE AND CORRECT REPRESENTATION OF A SURVEY OF THE BOUNDARIES OF; LOT 3, BLOCK 1, MURPHY FARM DAKOTA COUNTY, MINNESOTA 11 DOES NOT PURPORT TO SHOW IMPROVEMENTS OR ENCHROACH MENTS, EXCEPT DOWN. A$ SURVEYED BY ME UNDER MY DIRECT SUPERVISION THIS 9TH DAY OF OCTOBER,' 1995. GNED:? PIONEER ENGINE ING, P A ?, c, I Sa SCALE : 1 INCH = 40 FEET „hn a. ?rnQ^I I aRq. Na. 1982E Jr,_ .*:,* * 4L * PIONI * e **** Certificate of Survey for: V.11YtTr/ Spu+?? ?.O.rvlr.l 2422 Enterprise Drive Mendota Heights, MN 55120 (612) 681-1914 FAX:681-9488 LAND PLANNVAS, IANASCAPE ARCHITECTS [625 Highwoy 10 N.E. Blaine, MN 55434 (612) 78.-1880 FAX:783-1883 STEINWAND BUILDERS, INC. 366Y DONEGAL WAY, EAGAN, MN BENCH MARK DONEGAL TOP OF PIPE ELEV.^914.74 (VACANT) 1JD0 0`Cll 91 g"E . W 3 6 a ' ?11M1?0 906.1 1 ?" g0 V 906.7 ? > \ gl i.. a: ?Sry/ T N S 4;QJ?F tP r-1 r 1 . ?`ld S/ ,v 535 0 907.2 / ?p p0 ?o /g 5p 914.8 / ? a v7• ` j' ? ? 4 ? 909.3 "? S ?l qC J` I\ A WAY-\ 1 r 5 v' 911.4 1 , "4F 'ra2.,:A 901.7 ryA? \ 1 O. \ ?p I i ? ?3S'6 10.2 / 2 \ 9.2 ti \ 906.9 `t r / 3 ?1r \ s? i?o D9 ?4z ?s bq r? M 62 e1 (VACANT) r 9 r 7 Y 7 r r r r` //Q?1 i AV I A A D TR NW __89 r7 8 ND . jOPOSLD HO''.1.,>;,,` ELEVA II N ??•' LOWEST FLOOR ELEVATION. TOP OF BLQCK ELEVATION: ?".',:AGE SLAB ELEVATION: too YRr HWL.=894.1 r r N TE: PROPOSED G ( N?TP-9UIL`O7-NG SI >j. "OF $TRUCTURES/ I FMINnATrn Di5E g ;;00,00 DENOTES EXISTING ELEVATION ( 000.00 ) DENOTES PROPOSED ELEVATION DENOIES DRAINAGE AND UTILITY EASEMENT DENOTES DRANACE FLOW DIRECTION -?? DENOTES MONUMENT -? DENOTES OFFSET HUB LADING _PEAN .BYE._BRW FOR HOR12ONTAL AND VERTICAL LOCATION IE4TUAL PLANS-FOR BUILDING AND p(Ip ,[ NOTE. NO`SPECIW_ IL5 INVE70GR T10N Has OCEN CCNPLE TEO ON THIS LOT 0'/ THE I ?(`?3 t SURVEYOR. THE SUITA6141TY OF SOILS 10 SUPPORT THE SPECIFIC HOUSE NV9*.3'0ry 7"E 86055 PROPOSED IS NOT THE RESPONSIRILITY OF THE SURVEYOR. THE RECORDED PURPORT TO SHOW EA55MENTS OTHER THAN PLAT. .7 J .l G fTC7 NOTE: THIS THOSE ON DOES NOT NOTE: CONTRACTOR MUST VERIFY DRIVEWAY OESIGN. NOTEi SEARING$ SHOWN ARE BASED ON AN ASSUMED DATUM WE HEREBY CERTIFY TO STEINWAND BUILDERS, INC. THAT THIS IS A TRUE AND CORRECT REPRESENTATION OF A SURVEY OF THE BOUNDARIES OF LOT 3, BLOCK 1, MURPHY FARM DAKOTA COUNTY, MINNESOTA IT DOES NOT PURPORT TO SHOW IMPROVEMENTS OR ENCHROACHMENTS, EXCE-.SHOWN, AS SURVEYED BY ME OR UNDER MY DIRECT SUPERVISION THIS 9TH DAY OF Q/CTOBER •' 19w ) PI ONEER ENGINEE NO. P A• U ( ) T (Y 1 Poi ND. 198'28 SCALE : 1 INCH = 40 FEET Juhn G III PERMIT City of Eagan Permit Type:Building Permit Number:EA113101 Date Issued:08/29/2013 Permit Category:ePermit Site Address: 3967 Donegal Way Lot:3 Block: 1 Addition: Murphy Farm PID:10-49500-01-030 Use: Description: Sub Type:Reroof Work Type:Replace Description: Census Code:434 - Zoning: Square Feet:0 Occupancy: Construction Type: Comments:If there is no ice protection inspection prior to final, the contractor must meet the inspector w/ a ladder and flat bar. Pictures are not acceptable in lieu of inspections. Carbon monoxide detectors are required by law in ALL single family homes . Matt Wagoner Valuation: 4,000.00 Fee Summary:BL - Base Fee $4K $103.25 0801.4085 Surcharge - Based on Valuation $4K $2.00 9001.2195 $105.25 Total: I hereby acknowledge that I have read this application and state that the information is correct and agree to comply with all applicable State of Minnesota Statutes and City of Eagan Ordinances. Contractor:Owner:- Applicant - Joan C Peterson 3967 Donegal Way Eagan MN 55122 Limitless Construction Inc 8951 HWY 55 Golden Valley MN 55427 (612) 240-9364 Applicant/Permitee: Signature Issued By: Signature PERMIT City of Eagan Permit Type:Building Permit Number:EA136777 Date Issued:05/31/2016 Permit Category:ePermit Site Address: 3967 Donegal Way Lot:3 Block: 1 Addition: Murphy Farm PID:10-49500-01-030 Use: Description: Sub Type:Windows/Doors Work Type:Replace Description:Two or More Windows/Doors Census Code:434 - Zoning: Square Feet:0 Occupancy: Construction Type: Comments:Improvements to the home require smoke detectors in all bedrooms. If altering window openings or installing Bay or Bow windows, call for framing inspection. Call for final inspection after installation. Carbon monoxide detectors are required within 10 feet of all sleeping room openings in residential homes (Minnesota State Valuation: 4,000.00 Fee Summary:BL - Base Fee $4K $103.25 0801.4085 Surcharge - Based on Valuation $4K $2.00 9001.2195 $105.25 Total: I hereby acknowledge that I have read this application and state that the information is correct and agree to comply with all applicable State of Minnesota Statutes and City of Eagan Ordinances. Contractor:Owner:- Applicant - Joan C Peterson 3967 Donegal Way Eagan MN 55122 Renewal Andersen 1920 County Road C West Roseville MN 55113 (651) 264-4777 Applicant/Permitee: Signature Issued By: Signature PERMIT City of Eagan Permit Type:Building Permit Number:EA136777 Date Issued:05/31/2016 Permit Category:ePermit Site Address: 3967 Donegal Way Lot:3 Block: 1 Addition: Murphy Farm PID:10-49500-01-030 Use: Description: Sub Type:Windows/Doors Work Type:Replace Description:Two or More Windows/Doors Census Code:434 - Zoning: Square Feet:0 Occupancy: Construction Type: Comments:Improvements to the home require smoke detectors in all bedrooms. If altering window openings or installing Bay or Bow windows, call for framing inspection. Call for final inspection after installation. Carbon monoxide detectors are required within 10 feet of all sleeping room openings in residential homes (Minnesota State Valuation: 4,000.00 Fee Summary:BL - Base Fee $4K $103.25 0801.4085 Surcharge - Based on Valuation $4K $2.00 9001.2195 $105.25 Total: I hereby acknowledge that I have read this application and state that the information is correct and agree to comply with all applicable State of Minnesota Statutes and City of Eagan Ordinances. Contractor:Owner:- Applicant - Joan C Peterson 3967 Donegal Way Eagan MN 55122 Renewal Andersen 1920 County Road C West Roseville MN 55113 (651) 264-4777 Applicant/Permitee: Signature Issued By: Signature PERMIT City of Eagan Permit Type:Mechanical Permit Number:EA142903 Date Issued:05/23/2017 Permit Category:ePermit Site Address: 3967 Donegal Way Lot:3 Block: 1 Addition: Murphy Farm PID:10-49500-01-030 Use: Description: Sub Type:Residential Work Type:Replace Description:Air Conditioner Comments:Questions regarding electrical permit requirements should be directed to State Electrical Inspector, Mark Anderson at (952) 445-2840. Carbon monoxide detectors are required within 10 feet of all sleeping room openings in residential homes (Minnesota State Fee Summary:ME - Permit Fee (Replacements)$59.00 0801.4088 Surcharge-Fixed $1.00 9001.2195 $60.00 Total: I hereby acknowledge that I have read this application and state that the information is correct and agree to comply with all applicable State of Minnesota Statutes and City of Eagan Ordinances. Contractor:Owner:- Applicant - Joan C Peterson 3967 Donegal Way Eagan MN 55122 (651) 485-7805 Standard Heating & Air Conditioning 130 Plymouth Ave. N Minneapolis MN 55411 (612) 824-2656 Applicant/Permitee: Signature Issued By: Signature PERMIT City of Eagan Permit Type:Building Permit Number:EA149152 Date Issued:05/09/2018 Permit Category:ePermit Site Address: 3967 Donegal Way Lot:3 Block: 1 Addition: Murphy Farm PID:10-49500-01-030 Use: Description: Sub Type:Windows/Doors Work Type:Replace Description:One Window/Door Census Code:434 - Residential Additions, Alterations Zoning: Square Feet:0 Occupancy: Construction Type: Comments:Improvements to the home require smoke detectors in all bedrooms. If altering window openings or installing Bay or Bow windows, call for framing inspection. Call for final inspection after installation. Carbon monoxide detectors are required within 10 feet of all sleeping room openings in residential homes (Minnesota State Valuation: 1,500.00 Fee Summary:BL - Base Fee $1500 $62.50 0801.4085 Surcharge - Based on Valuation $1500 $0.75 9001.2195 $63.25 Total: I hereby acknowledge that I have read this application and state that the information is correct and agree to comply with all applicable State of Minnesota Statutes and City of Eagan Ordinances. Contractor:Owner:- Applicant - Joan C Peterson 3967 Donegal Way Eagan MN 55122 Renewal Andersen 1920 County Road C West Roseville MN 55113 (651) 264-4777 Applicant/Permitee: Signature Issued By: Signature PERMIT City of Eagan Permit Type:Plumbing Permit Number:EA152915 Date Issued:11/08/2018 Permit Category:ePermit Site Address: 3967 Donegal Way Lot:3 Block: 1 Addition: Murphy Farm PID:10-49500-01-030 Use: Description: Sub Type:Residential Work Type:Replace Description:Water Heater Meter Size Meter Type Manufacturer Serial Number Remote Number Line Size Comments:Please call Building Inspections at (651) 675-5675 to schedule a final inspection. Allow an 18" minimum radius clearance to the water meter from all appliances (i.e. furnace, water heater, water softener). Fee Summary:PL - Permit Fee (WS &/or WH)$59.00 0801.4087 Surcharge-Fixed $1.00 9001.2195 $60.00 Total: I hereby acknowledge that I have read this application and state that the information is correct and agree to comply with all applicable State of Minnesota Statutes and City of Eagan Ordinances. Contractor:Owner:- Applicant - Joan C Peterson 3967 Donegal Way Eagan MN 55122 (651) 485-7805 Warner Stellian Co Inc 550 Atwater Circle St Paul MN 55103 (651) 222-0011 Applicant/Permitee: Signature Issued By: Signature