Loading...
1685 Donegal CtAddress 1685 DONEGAL CT, EAGM, MN Lot in Blk 1 Zip 5512 3 Sub mmwav FArmr THESE ITEMS WERE / WERE NOT COMPLETE AT THE TIME OF THE FINAL INSPECTION. Date: ?-A /? p Yes No Inspector: a-fj Final grade (6" from siding) Permanent steps (garage) Permanent steps (main entry) Permanent driveway v Permanent gas v Sod/Seeded grass L/ Trail/curb damage //- Porch l/ Basement finish 1l Deck f? Please verify with the builder the removal of roof test caps from the plumbing system and the shutoff of water supply to the outside lawn faucet before freeze potential exists. Contact engineering division at 681-4645 before working in right-of-way or installing underground sprinkler system. White - City Copy Yellow -Resident Copy Pink - Contractor Copy r_ certificate of CCCupancC lgit? of Wagan Tepartraent of zKoing anapecrion This Certificate issued pursuant to the requirements of the Uniform Building Code certifying that at the time of issuance this structure was in compliance with the various ordinances of the City regulating building construction or use. For the following: a tu, / •. Use Classification: S' DWG Bldg. Permit No. 34441' Occupancy Type ZAgigg District Type Const. Owner of Building , IM Addr., 7694 120th K W APPLE VM M • M Building Add. 1685 D(11EGAL CT Locality Ltd, B1, KJRPHY FARO Date f Building Official POST IN A CONSPICUOUS PLACE CITY OF EAGAN 3830 Pilot Knob Road Eagan, Minnesota 55122-1897 (612) 681-4675 SITE ADDRESS: PERMIT SUBTYPE: RU 1 1 It I N6 0 t1 44,' A?/tt/Ith TYPE OF WORK: INSPECTION TYPE DDATE INSPTR INSPECTION TYPE DATE INSPTR. . L 1- ?akW W V N : I7 1 WF t tIFIN 1 CAI PI AN REVIIW11) ti`I 104 1Pr F i ON ;CORD PERMIT TYPE: Permit Number: Date Issued: to fit fl o k I APPLICANT: 3 I Permit No. Permit Holder Date Telephone # ELECTRIC PLUMBI ?3 ya3 37?v HVAC /,Ic S9?-Ooo In9peetion Date Insp. Comments FOOTINGS J/-)'A ? 4, FOUND FRAMING ROOFING ROUGH PLUMBING PL REST 'r If L?7.3 / $ L J ROUGH HEATING 97- ilAT a y-fj - 9 a f ??j/ GAS SVC TEST y( INSUL G/!7(?? /all?? GGr// GYP BOARD FIREPLACE 7? d FIREPLACE AIR TEST FINAL PLBG s/,ZLIQ FINAL HTG ORSAT TEST BLDG FINAL BSMT R.I. BSMT FINAL DECK FTG ??cJ I DECK FINAL ` K/ Ra" qa_e_? ¦ WA071\7 IG1 XIMI 104 ON: ATTORNEYS AT LAM, 7301 ORms LANE, SUITE 360 ' MINNEAPOLIS, MN 55439 TELEPHONE (952) 844-9033 FACSIMILE (952) 844-0114 DAVID D. HAMMARGREN w .nAMMAELAw.COM PAUL T. MEYER* TIMOTHY C. COOK BRENDA M. SAURO JENNIFER A. THOMPSON ANTHONY W. THOMPSON ' Lsowsan Pwrcm,onu, Encwecv VIA U.S. MAIL June 26, 2007 City of Eagan Building Inspections 3830 Pilot Knob Rd. Eagan, MN 55122 RE,: Mitchell and Andrea Goldberger 1685 Donegal Court Eagan, MN 55122 Dear Sir or Madam: Writer's direct dial (952) 224-2926 Writer's e-mail sara@hammarlaw.com This office represents Mitchell and Andrea Goldberger, owners of a single family home at 1685 Donegal Court, Eagan, MN. Pursuant to Minn. Stat. Ch. 13, the Government Data Practices Act, I am requesting access to any and all files, documents or information in the City's possession relating to or arising out of the design and construction of the Goldberger home located at 1685 Donegal Court request includes, but is not limited to, the following: 1. Applications for any and all building permits and the permits themselves. 2. All plans, drawings or other documents submitted to the Citv in connection with the construction of the home plus any comments or orders issued by me City. 3. All inspection records and notes. 4. All correspondence, notes, memos or other documents in the City's files relating to this home. If all items can be copied and sent to my attention for under $100.00 please have them copied and mailed to my attention. Please call me with the applicable charges and I will be certain you receive payment. If the copying costs will exceed $100.00 and /or if we must personally review and copy the documents at your offices, please make such arrangements with me at (952) 224-2926. ??I?GC`IIC?n JUN 2 1 Luut I? , CITY OF EAGAN 3830 Pilot Knob Road Eagan, Minnesota 55122-1897 (612) 681-4675 SITE ADDRESS: PERMIT PERMIT TYPE: Permit Number: Date Issued: 1685 DONEGAL CT LOT: 10 BLOCK: 1 MURPHY FARM DESCRIPTION: SF OWG NEW R-3 U-1 VN R-1 69 56 2 2,277 101 1 - FAM. DETACH :6? IM u 'hassc as V?P @ a4mA`a4 ;-r`& i Nwk r ,. BUILDING 031442 02/11/98 REMARKS: S&W: WENZEL MECHANICAL PLAN REVIEWED BY MIKE BARCK FEE SUMMARY: VALUATION Base Fee $1,467.25 Plan Review $953.71 Surcharge $108.00 SAC $1,000.00 SAC 100 SAC Units 1 Subtotal $3,528.96 $216,000 MISC. FEES $1.592.50 Total Fee $5,121.46 CONTRACTOR: - Applicant - ST. LIC OWNER: K0f HOMES, R A 16879513 0001506 R.A. KOT HOMES, INC. 7694 128TH ST W 7694 120TH ST. W APPLE VALLEY MN 55124 APPLE VALLEY MN 55124 (6'12) 687-9513 (612)687-9513 ? 1 gall,' I: ?I? c:r'rv OF EAGWiN DATE M?11:1.199 T:I:NE: ,T. 11 NAME"u ( A h'OI F4 MFr4.' INC. 900j. 160".'i DONEGAL Cr `i (r lr:lr?????' i ' ? .. .? ? ? . .1 ?I :'. r }. '. ... ail P'I •?..I ):?? ? `?!^: 1:.I ..I ..I... ,i i. ,v,.ii T a :. p n"! !n .r?, .-i ,. •?'?r :rr II;- ,.r ? 4?rr fry:, : ?? 1998 BUILDING PERMIT APPLICATION (RESIDENTIAL) ?l CITY OF EAGAN 3830 PILOT KNOB RD - 55122 681-4675 New Construction Requirements Remodel/Repair Requirements ? 3 registered site surveys ? 2 copies of plan ? 2 copies of plans (include beam & window saes; poured find. design; etc.) ? 2 site surveys (exterior additions & decks) ? 1 energy calculations ? 1 energy calculations for heated additions • 3 copies of tree preservation plan If lot platted after 7/1193 required: _ Yes _ No DATE: ?S ?f DESCRIPTION OF W STREET ADDRESS: LOT: ( o CONSTRUCTION COST; 29 S-00 C1 BLOCK: SUBD./P.I.D. Name: 9C % _ & Phone #: G O 7' qS 1,3 PROPERTY Last First OWNER Street City State: Zip: Company: 9 -/1-I`?! 17p"-S' -z' Phone #: CONTRACTOR Street Address: 7/ ST k,) License# ODCJ/S' 4 _(/Ji State: _ Zip: 5.-1 2 City A?W ENGINEERT/ Company: U t'S it Phone #: 8 2- q --13 Registration #: Street City State: Zip: Sewer & water licensed plumber (new construction only): WCM 2- ? A-L C lo-11 ca (Penally applies when address Chang and lot change is requested once permit is issued. hereby acknowledge that I have read this application and state that the information ' oort nd agree to comply with all applicabl State of Minnesota Statutes and City of Eagan Ordinances. /j / I/ , Signature of Applicant OFFICE :USE O Y - Certificates of Survey Received Yes No 60 Tree Preservation Plan Received Yes No Not Require OFFICE USE ONLY BUILDING PERMIT TYPE ? 01 Foundation ? 06 Duplex Rr 02 SF Dwelling ? 07 4-plex ? 03 SF Addition ? 08 8-plex ? 04 SF Porch ? 09 12-plex ? 05 SF Misc. ? 10 _-plex WORK TYPE 0'31 New ? 33 Alterations ? 32 Addition ? 34 Repair GENERAL INFORMATION Const. (Actual) (Allowable) UBC Occupancy Zoning # of Stories Length Depth APPROVALS ? 11 Apt./Lodging ? 12 Multi Repair/Rem. ? ? 13 Garage/Accessory ? ? 14 Fireplace ? ? 15 Deck ? 36 Move ? 37 Demolition 16 Basement Finish 17 Swim Pool 20 Public Facility 21 Miscellaneous ?nl /? Basement sq. ft. Main level sq. ft. } -? 7-4 sq. ft. R-I sq. ft. 2 sq. ft. L,?'? sq. ft. .5 L' k+" Footprint sq. ft Planning Permit Fee Surcharge Plan Review License MCAJVS SAC City SAC Water Conn. Water Meter Acct. Deposit S/W Permit S/W Surcharge Treatment PI. Park Ded. Trails Ded. Other , Building Ama 1553 MC/WS System 15 s3 City Water ,`ian Fire Sprinklered '12 ,4 Booster Pump Census Code. ,o ZZ 7 7 SAC Code r Census Bldg Census Unit I Engineering Variance Valuation: 5e?hsw'i'- 7 yW 29 2 riz zq z82-srIz rl oH 'H's X/G 232 2N7 ,H yv"3 -52. Zulz 24 22 w(2. S 2')S ,553 t4 i 24 2",/ 2Y/z 32>r ? zy?` 8.S wiz s ? +? a $ z, v,aOO. De clz ,, 2- U 0, z, s, rp92s _ 3a sas.- , 553 cb il 54= z8 z4 X08$ ?9,z3 l+y crp ? ? S`? - Z. L yg' lb !L 83, a-LZ goy 41,0, o8z 0--' L?? 9- `CJ Q-? ? 4/ ? ?• ? M--? ? 0 w !pN? L 0,? ? ? ? ? Ey ? ? ? qi ? ELEVATIONS Extstina • Sewer service (or Proposed) • Property corners • Top of curb at the driveway • Elevations of any existing adjacent homes Proposed ra, ? ? E3' ? ? al ? ? ? ? ? Cy ? ? ? ?? ? ? Er- ? ? [7, ? ? ET ? ? C? ? 4?" ? ? El" ? ? ??'? ? M, ? ? EY ?? /Q ? c ? • Garage floor • First floor • Lowest exposed elevation (walkout/window) • Property corners • Front and rear of home at the foundation PONDING AREA (iapplicable) Easement line NWL HWL Pond # designation Emergency Overflow Elevation DIMENSIONS Lot lines/Bearings & dimensions Right-of-way and street width (to back of curb) Proposed home dimensions including any proposed decks, overhangs greater than 2', porches, etc. (i.e. all structures requiring permanent footings) Show all easements of record and any City utilities within those easements Setbacks of proposed structure and sideyard setback of adjacent existing structures Retaining wall Reviewed: PROPERTY LEGAL: LOT SURVEY CHECKLIST FOR RESIDENTIAL BUILDING PERMIT APPLICATION DATE dF SURVEY: 6?' / CIJ'?-" LATEST REVISION: 2T1(111 DOCUMENT STANDARDS • Registered Land Surveyor signature and company • Building Permit Applicant • Legal description • Address • North arrow and scale • House type (rambler, walkout, split w/o, split entry, lookout, etc.) • Directional drainage arrows with slope/gradient % • Proposed/existing sewer and water services & invert elevation • Street name • Driveway January 1We CRAIG19QWBLDGPRMT.FM EXTERIOR ENVELOPE AVERAGE "U" COMPUTATION OWNER R.A. KOT HOMES, INC. PLAN NO. 9-1231-7 SITE ADDRESS LOT 10, BLK 1, MURPHY FARM CONTRACTOR: R.A. ROT HOMES, INC. DATE 01/03/98 PHONE 687-9513 DETERMIME WORKING SQUARE FOOTAGE 5053.079 1. Total exposed wall area 5120.3 sq.ft. x .11 563.233 2. Total roof/ceiling area 1910 sq.ft x .025 49.66 3. Total floor cant. area 91.68 sq.ft. x 0.05 4.584 (over unheated enclosed areas) 4. Total floor cant. area 8 sq.ft. x 0.025 0.2 (over unheated exposed areas) 5. Total exposed wall area above the floor. 4646.079 a. Total wall window area .................... 636.895 b. Total door area ........................... 55.6278 C. Total sliding glass door area ............. 60.03 d. Total fireplace area ...................... 0 e. Total wall framing area (ave. 10%)........ 464.6079 f. Total net wall area above the floor....... 3428.919 g. Total rim joist area ...................... 407 TOTAL EXPOSED FOUNDA'T'ION AREA ................ 67.2211 h. Total foundation window area .............. 0 i. Total net foundation area ................. 67.2211 Determine "U" value of each wall segment. a. 636.895 x "U" 0.41 = b. 55.6278 x "u" 0.06 = C. 60.03 x "U" 0.33 = d. 0 x "U" 0 = e. 464.6079 x "U"- 0.097752 = f. 3428.919 x "U" 0.044843 = g. 407 x "u" 0.042123 = h. 0 x "U" 0.41 = i. 67.2211 x "u" 0.073638 = 261 .127 3.337668 19.8099 0 45.41622 153.7632 17.14406 0 4.950007 6 .....................................Total 505.548 If item #6 is the same as or less than item #1 you have met.the current energy codes. 2 MCAR 1.16008 A AND O. TOTAL EXPOSED ROOF/CEILING AREA j. Total skylight area ....................... k. Total flat roof/ceiling framing area...... 1. Total net flat roof/ceiling area.......... Determine "U" value for each roof/clg j- 0 x "U" 0 = k. 191 x "U" 0.025549 = 1. 1719 x "U" 0.021801 = 1910 0 191 1719 segment 0 4.879918 37.47547 9 7 ...................................Total. 42.35539 If item #7 is the same as or less than item #2 you have met the energy code. 2 MCAR 1.16008 A AND O. TOTAL FLOOR CANT. AREA (enclosed). 91.68 o. Total floor cant. framing area (ave. 10%). 9.168 p. Total net insulated floor/cant. area...... 82.512 Determine "U" value for each floor/cant. segment. 0. 9.168 x "U" 0.047192 = 0.432657 P. 82.512 x "U" 0.021622 = 1.784043 6 ...................................Total 2.2167 If item #8 is the same as or less than item #3 you have met the energy code. 2 MCAR 1.16008 A AND 0. TOTAL, FLOOR/CANT. AREA (exposed) 8 q. Total floor/cant. framing area (ave. 10%). 0.8 r. Total net insulated floor/cant. area...... 7.2 Determine "U" value for each floor/cant. segment. q. 0.8 x "U" 0.039793 = 0.031834 r. 7.2 x "U" 0.019924 = 0.143455 9 ...................................Total If item #9 is the same as or less than item #4 you have met the energy code. 2 MCAR 1.16008 A AND O. I HEREBY CERTIFY THAT I HAVE CALCULATED THE "U" FACTORS AND "R" VALUES HEREIN AND THAT THE BUILDING HERE D SCRIBED MEETS OR EXfc THE STATE OF MINNESOTA ENERGY CONSERVATION ACT. Fi i (sig/n?tu/re} 0.175289 S ANSWER THESE QUESTIONS ABOUT THE STRUCTURE. (in the case of windows and doors, round up to next foot.) 1. WHAT IS THE TOTAL LIN. FT. OF SECOND FLOOR RIM JOIST?...... 192 2. WHAT IS T HE TOTAL LIN. FT. OF FIRST FLOOR RIM JOIST?........ 215 3. HOW MANY LIN. FT. OF 1ST. FL. RIM HAS PARTIAL W/O BELOW?... 66.67 4. HOW MANY IIN. FT. OF 1ST. FL. RIM HAS FULL W/O BELOW?...... 48 5. WHAT IS THE TOTAL INSULATED CEILING SQ. FOOTAGE?........... 1910 6. HOW MANY PANES OF WINDOW GLASS ARE THERE? .................. 75.5 6A. HOW MANY 2' HIGH? ................................ 22.5 6B. HOW MANY 3' HIGH? ................................ 2 6C. HOW MANY 4' HIGH? ................................ 14 6D. HOW MANY 5' HIGH? ................................ 35.5 6E. HOW MANY 61OR MORE HIGH? ......................... 1.5 7. HOW MANY 3FT. EXTERIOR DOORS ARE THERE? .................... 1 8. HOW MANY 218" EXTERIOR DOORS ARE THERE? .................... 2 9. HOW MANY SL. GLASS DRS. OR ATRIUM DRS. ARE THERE AT: 0 9A. 5'0" ............................................. 0 9B. 6'0" ............................................. 1.5 9C. 7'0" ............................................. 0 9D. 8'0" ............................................. 0 9E. 9'0" ............................................. 0 10. WHAT IS THE SQ. FOOTAGE OF SKYLIGHTS? ...................... 0 11. WHAT IS THE 1ST FL. SQ. FOOTAGE? .......................... 1740 12. WHAT IS THE SECOND FLOOR SQ. FOOTAGE? ...................... 1367 13. WHAT IS THE 1ST FLOOR CEILING HGT.? ...............AVG... 10.5 14. WHAT IS THE 2ND FLOOR CEILING HGT.? ........................ 8.17 15, WHAT IS THE TOTAL ENCLOSED CANT. SQ.FT ..................... 91.68 16. WHAT IS THE TOTAL EXPOSED CANT. SQ.FT ...................... 8 17. WHAT IS THE TOTAL FOUNDATION WINDOW AREA ................... 0 DETERMINE "U" VALUES" THRU STUD WITH SIDING & S.R. Interior Air...... 0.68 Sheet Rock........ 0.45 Thermo-Break...... 0 Stud .............. 6.93 Shthng(Bracerite). 1.22 Siding............ 0.78 Exterior Air...... 0.17 Total "R" Value..... ....... 10.23 1/R = "U" Value ..... ....... 0.097752 THRU INSULATION WITH SIDING & S.R. Interior Air...... 0.68 Sheet Rock........ 0.45 Thermo-Break...... 0 Insulation........ 19 Shthng(Bracerite). 1.22 Siding............ 0.78 Exterior Air...... 0.17 Total "R" Value............ 22.3 1/R = "U" Value ............ 0.044843 THRU CEILING MEMBER Interior Air...... 0.68 Sheet Rock........ 0.58 Ceiling Member.... 4.35 Insulation........ 32.92 Still Air......... 0.61 Total "R" Value............ 39.14 1/R = "U" Value ............ 0.025549 THRU CEILING INSULATION Interior Air...... 0.68 Sheet Rock........ 0.58 Insulation........ 44 Still Air......... 0.61 Total "R" Value............ 45.87 1/R = "U" Value ............ 0.021801 THRU CONCRETE BLOCK Interior Air...... conc. Blk......... Insulation........ Sheet Rk. (opt.). Exterior Air...... 0.68 1.28 11 0.45 (Add 0.45 0.17 Total "R" Value............ 13.58 1/R = "U" ..................0.073638 THRU RIM JOIST Interior Air...... Insulation........ Rim Joist......... Shthng(Braceri.te). Siding............ Exterior Air...... 0.68 19 1.89 1.22 0.78 0.17 Total "R" Value............ 23.74 1/R = "U" ................ 0.042123 U" value for window........ U" value for doors......... U" value for Patio Drs..... THRU CANT. @ MEMBER (enclosed) Interior air...... 0.68 Finish Flooring... 1.23 Shthng(Bracerite). 1.22 Plywood........... 0.93 Joist(W/2x4 Furr). 15.94 Sheet Rock........ 0.58 Still Air......... 0.61 0.41 0.06 0.33 Total "R" Value............ 21.19 1/R = "U" ..................0.047192 THRU CANT. @ INSULATION Interior Air...... 0 Finish Flooring... 1 Shthng(Bracerite). 1 Plywood........... 0 Insulation........ Sheet Rock........ 0 Still Air......... 0 (enclosed) 68 23 22 93 41 58 61 Total "R" Value............ 46.25 1/R = "U" ..................0.021622 (Assumes 200 Joists) THRU CANT. @ MEMBER (exposed) Interior Air...... 0.68 Finish Flooring... 1.23 Underlayment...... 0 Plywood........... 0.93 Joist(W/2x4 Furr). 15.94 Shthng(3/4" RMAX). 5.4 Soffit............ 0.78 Exterior Air...... 0.17 Total "R" Value............ 25.13 1/R = "U" ..................0.039793 Interior Air...... 0.68 Finish Flooring... 1.23 Underlayment...... 0 Plywood........... 0.93 Insulation........ 41 Shthng(3/4" RMAX). 5.4 Soffit............ 0.78 Exterior Air...... 0.17 THRU CANT. @ INSULATION (exposed) (Assumes 200 Joists) Total "R" Value............ 50.19 1/R = "U" ..................0.019924 CITY USE ONLY L BL RECEIPT#: O G SUB `. RECEIPT DATE: 3 1998 PLUMBING PERMIT (RESIDENTIAL) CITY OF EAGAN 3830 PILOT KNOB RD EAGAN, MN 55122 (612) 681-4675 Please complete for: ? single family dwellings ? townhomes and condos when permits are required for each unit ? backflow preventer for underground sprinkler system FIXTURES _ _ ^ EACH # TOTAL Shower 3.00 x \d.40 Water Closet 3.00 x 13 = 99-40 Bath Tub 3.00 x .2. = L.oD Lavatory 3.00 x _ A,57eo Kitchen Sink 3.00 x \31ao Laundry Tray 3.00 x Hot Tub/Spa 3.00 x = Water Heater 3.00 x Floor Drain 3.00 x Gas Piping Outlet * minimum - 1 3.00 x _ \3.00 Rough Openings 1.50 x S = -So Water Softener * for dwellings under construction 5.00 x = Water Softener * forexisting dwelling 20.00 x = U.G. Sprinkler * for dwelling under const. 3.00 = U.G. Sprinkler * for existing dwelling 20.00 = Alterations * to existing residence 20.00 = Water Turn Around 20.00 = Private Disposal System * MPC lic. 75.00 = (new and refurbished systems) Private Disposal Systems * Abandonment 20.00 = STATE SURCHARGE .50 TOTAL _Sh.bn - ------ ----- --- - ------ --- ----- - ------ --- --------------•- ----- --- ------ Ihereby acknowledge that I have read this application, state that the information is correct, and agree to comply with all applicable City of Eagan ordinances. It is the applicant's responsibility to notify the property owner that the City of Eagan assumes no liability for any damages caused by the City during its normal operational and maintenance activities to the facilities constructed under this permit within City property/right-of-wayleasement. SITE ADDRESS: OWNER NAME: INSTALLER NAME: i1LiuJ fl/? r??f? .ice.. TELEPHONE # -,?5-3`Xw STREET ADDRESS: d CITY: xlJ ut r t, STATE: ZIP: S?i069, JS/FORMS BLDG/PLBG PERMIT (RESIDENTIAL) 1998 CITY USE ONLY LQT A? 131, RECEIPT SU 9B ?Y/3 L, RECEIPT DATE: 1998 MECHANICAL PERMIT (RESIDENTIAL) CITY OF EAGAN 3830 PILOT IQ70B RD EAGAN MN 55122 (612) 681-4675 Date: 130q?? Complete this section only if you are installing HVAC in single family, townhomes or condos under construction and not owner /occupied • HVAC: 0-100 M B T U $ 24.00 ADDITIONAL 50 M BTU .00 • Gas outlets (minimum of one required @ $3.00 ea.) 35c) • State Surcharge: .50 • TOTAL: 33.50 Complete this section only if you are remodeling, adding to, or repairing existing single family dwellings, townhomes, or condos. Note: Mechanical permit is not required for alteration/add-on to ductwork in existing residential units; but is required for the following: Install furnace Install air conditioning Install air exchanger, i.e. Vanee system, etc. Other Minimum fee applies to all remodel or add-ons of existing residences $ 20.00 State Surcharge .50 Total: $ 20.50 SITE ADDRESS: OWNER NAME: )e 9eb- PHONE#: a6,f7- g5-1 INSTALLER NAME: PHONE #: d Q O?5 STREET ADDRESS: IcZyXI (tJQy 1?//??lL? ?U? 5, CITY: ST TE: ZIP: ???3?? 42 -IGNATURE OF PERMIT IS/FORMS BLD/MECH PERMIT (RES) - 1998 CITY USE ONLY L BL SUBD. RECEIPT * RECEIPT DATE: 1998 MECHANICAL PERMIT (COMMERCIAL) CITY OF EAGAN 3830 PILOT KNOB RD EAGM, MN 55122 (612) 681-4675 Please complete for all commerciallindustrial buildings multi-family buildings when separate permits are not required for each dwelling unit DATE: CONTRACT PRICE: WORK TYPE: NEW CONSTRUCTION INTERIOR IMPROVEMENT DESCRIPTION OF WORK: FEES: 1 % of contract price OR $25.00 minimum fee, whichever is greater. Processed piping - $25.00 CONTRACT PRICE x 1% PROCESSED PIPING PERMIT FEE STATESURCHARGE TOTAL SITE ADDRESS: ($.50 per $1,000 of permit fee due on all permits.) OWNER NAME: TENANT NAME (IMPROVEMENTS ONLY): INSTALLER: ADDRESS: CITY: SIGNATURE OF PERMITTEE STATE: PHONE #: #: ZIP: CITY INSPECTOR L _1d BL CITY USE ONLY RECEIPT#: 9&o 9 SUBD.' RECEIPT DATE: Old 1998 PLUMBING PERMIT (RESIDENTIAL) CITY OF EAGAN 3830 PILOT KNOB RD EAGAN, MN 55122 (612) 681-4675 Please complete for: ? single family dwellings ? townhomes and condos when permits are required for each unit D backflow preventer for underground sprinkler system FIXTURES EACH # TOTAL Shower 3.00 x = Water Closet 3.00 x = Bath Tub 3.00 x = Lavatory 3.00 x = Kitchen Sink 3.00 x = Laundry Tray 3.00 x = Hot Tub/Spa 3.00 x = Water Heater 3.00 x = Floor Drain 3.00 x = Gas Piping Outlet ' minimum -1 3.00 x = Rough Openings 1.50 x = Water Softener "for dwellings under construction 5.00 x = Water Softener * for existing dwelling 20.00 x = U.G. Sprinkler * for dwelling under const. 3.00 U.G. Sprinkler * for existing dwelling 20.0 = Alterations * to existing residence 20.00 = Water Turn Around 20.00 = Private Disposal System * MPC lic. 75.00 = (new and refurbished systems) Private Disposal Systems * Abandonment 20.00 = RPZ (new installation only) 20.00 = STATE SURCHARGE .50 TOTAL o2? ----------------------------------------------------------------------------------- I hereby admowledge that I have read this application, state that the information is correct, and agree to comply whh all applicable City of Eagan ordinances. It is the applicant's responsibility to notify the property owner that the City of Eagan assumes no liability for any damages caused by the City during its normal operational and maintenance activities to the facilities constructed under this permit within City property/right-of-way/easement. SITE ADDRESS: 4 OWNER NAME: ?l o AZ??pp=f INSTALLER NAME: pz TELEPHONE#: STREET ADDRESS: ?? l7 ya CITY: -ke-dx- STATE: Gam' ?- ZIP: ZE3 2 ISkKD LSDIJ SIGN TORE OF PERMITTEE Aj O wa CD/PERMIT FORMS/RPLBG PERMIT (RES) - 1998 J Address 1685 DONECAL CT, EAGM, NN Zip 5512 -.SL Lot to Blk i Sub ^°zm nmpw THESE ITEMS WERE / WERE NOT COMPLETE AT THE TIME OF THE FINAL INSPECTION. Date: ?1 a C? Yes No Inspector: Final grade (6" from siding) Permanent steps (garage) Permanent steps (main entry) vl? Permanent driveway V Permanent gas 1/ Sod/Seeded grass L/ Traillcurb damage l? Porch <f Basement finish Deck V" Please verify with the builder the removal of roof test caps from the plumbing system and the shut-on or water supply to the outside lawn faucet before freeze potential exists. Contact engineering division at 681-4645 before working in tight-of-way or installing underground sprinkler system. White - City Copy Yellow - Resident Copy Pink - Contractor Copy 11 it IT 41 * PIONEER * lft??fBBf? BENCH MARK jV a "! 10 5 TOP OF FIFE FafV=912.14 (y h / / I/ 12../00 y / 912.2 1 0 B.000 E S Certificate of Survey for: tANC SURK 2P.5 CMl i LuIJ Sirv+;En6• LANO^u(:AF( R.A. KOT 7..422 Enterprise Drive Mendota Heights, MN 55120 (612) 681--1914 FAX:681-9488 625 Highway 10 N... Blaine, IAN 55434 (612) 783-1880 FAX.783-1883 1693 DONEGAL COURT 2AQI'%m 112 1--2 E,,?"Q?. sos a N7 , -- z,l_1? 5/! z79?8ww 907.E Il 3 ILDING INSPECTIONS DEPb 4_-- 0R1'0 X000 q1° 10 ^. j x EAS'CM ?T h 79/fJ7'Z.X ?+??- T _? l 9T 0 910.fi 9 0 /{ 905.5 9 O eR "AT i j li /J J I 10 l.Y<???1R / 907.4 "To UL J 908.1 ? 971.6 -- 51 $18. ?G? `? DECK i 29.97 4°o 1123 1 i I N j 2.33 PROROSFyO /°D/ ' `?m BY DA _ 911.7 910.E X31 Tp3" ` / i 1 loll, P /// r 021 o I 0 1500 p 21.67 pj 11. 9-.7.8 ,. G15_oJ PROPOSED \ iSERVICE all DRIVEWAY INV_=901.0 ^ _ to 9114 S89R36'14"W 912.0 911,4 4f 3U i? N I 5j 9I2.9 30_02 ---J 10 _ Q 101.85 91 DONEGAL COURT 4 W z 0 BENCH MARK TOP OF PIPF? 5 I `M1 cLEY.=913.0_ tit t ) J 912.9 e L J NOTE: FROPOSED GRADES SHOWN PCB GRADING PLAN BY BAY NOTE: BUILDING O?MENSIONS SHOWN ARE FOR HORRONTAL ANO VERtICA'. LOCATION OF STRUCTURES ONLY, SEE ARCHITEC'TUAL PLANS FOR BVILC'ING AND FOUNVATION DIMENSIONS. NOTE: NO SPECIFIC SOILS INVESTIGATION HAS BEEN COMPLETES ON T/K LOT BY WE SURVEYOR. THE SUITABILITY Of SOILS TO SUPPORT THE HOU':E PROPOSED 15 NOT THE RESPONSIBILITY OF THE STRYF. 00- .PROPOSED HOUSE ELEYAL'DN_ r• LOWES( PLODR ELEVATION: .LZ TCP OF BLOCK ELEVATION: 1&-k. GARAGE SLAB ELEVATION: l Li' O NOIC THIS CERTIFICATE DOES NOT PURPORT TO SHOW EASEMENTS OTHER THAN X OOD.00 DENOTES EAISTING ELEVATION THOSE SHOWN ON THE RECORDED PLAT. t 000.00 ) DENIMS PROPOSED ELEYATION 401E: CONTRACTOR MUST VERIFY DRIVEWAY DESIGN. - - -- DENOTES DRAINAGE AND UTILITY EASEMENT - I DENOTES DRAINAGE FLOW DIRECTION NOTE BEARINGS SHOWN ARE BASED ON AN ASSUMED DATUM -?-- DENOTES MONUMENT 9 DENOTES OFFSET HUB VIE HEREBY CERTIFY TO R.A. KOT THAT THIS IS A TRUE AND CORRECT REPRESENTATION OF A FLIRVEY OF THE BOUNDARIES OF: LOT 10, BLOCK 1, MURPHY FARM DAKOTA COUNTY. MINNESOTA :T DOES N07 PURPORT TO Sr!OW IMPROVEMENTS OR ENC.HP,OACHMENTS, EXCEPT AS SHOWN, AS SURVEYED BY ME OR UNDER MY DIRECT SUPERVISION THIS 27TH DAY OF JAN_ 1998, /(?A Ule", /d' l„y SIGN', PIONEER ENGINEVRIN A. SCALE : 1 INCH = 30 FEET /),/=. el, v. BY( D, 1 9•d Use BLUE or BLACK Ink r-------------------, I For Office Use l' (fly" t i ! Permit#: I City of Faun I Permit Fee: 3830 Pilot Knob Road I I Eagan MN 55122 Date Received: Phone: (651) 675-5675 I I Fax: (651) 675-5694 I Staff: I I 2012 RESIDENTIAL BUILDING PERMIT APPLICATION Date: Site Address: Unit Namel~aK E (Iho dk Phone: ss RESIDENT 1 I OWNER Address/ City /Zip: 1 b De Q \ C _J P Applicant is: Owner Contractor TYPE OF WORK Description of work: S+0 Cco X~C W,I(A C?oxs Construction Cost: Multi-Family Building: (Yes / No ) Company: Contact: CONTRACTOR Address: City: State: Zip: Phone: License Lead Certificate If the project is exempt from lead certification, please explain why: (see Page 3 for additional information) COMPLETE THIS AREA ONLY IF CONSTRUCTING A NEW BUILDING In the last 12 months, has the City of Eagan issued a permit for a similar plan based on a master plan? _Yes _No If yes, date and address of master plan: Licensed Plumber: Phone: Mechanical Contractor: Phone: Sewer & Water Contractor: Phone: NOTE: Plans and supporting documents that you submit are considered to be public information. Portions of the information may be classified as non-public if you provide specific reasons that would permit the City to conclude that they are trade secrets. CALL BEFORE YOU DIG. Call Gopher State One Call at (651) 454-0002 for protection against underground utility damage. Call 48 hours before you intend to dig to receive locates of underground utilities. www.gopherstateonecall.org I hereby acknowledge that this information is complete and accurate; that the work will be in conformance with the ordinances and codes of the City of Eagan; that I understand this is not a permit, but only an application for a permit, and work is not to start without a permit; that the work will be in accordance with the approved plan in the case of work which requires a review and approval of plans. Exterior work authorized by a building permit issued in accordance with the Minnesota State Building Code must be completed within 180 days of permit issuance. x Ap lican 's Printed Name / App ' s Signature Page 1 of 3 PERMIT City of Eagan Permit Type:Mechanical Permit Number:EA167066 Date Issued:02/22/2021 Permit Category:ePermit Site Address: 1685 Donegal Ct Lot:10 Block: 1 Addition: Murphy Farm PID:10-49500-01-100 Use: Description: Sub Type:Residential Work Type:Replace Description:Furnace Comments:Carbon monoxide detectors are required within 10 feet of all sleeping room openings in residential homes (Minnesota State Building Code). Questions regarding electrical permit requirements should be directed to State Electrical Inspector, Pete DeGrood at (507) Fee Summary:ME - Permit Fee (Replacements)$59.00 0801.4088 Surcharge-Fixed $1.00 9001.2195 $60.00 Total: I hereby acknowledge that I have read this application and state that the information is correct and agree to comply with all applicable State of Minnesota Statutes and City of Eagan Ordinances. Contractor:Owner:- Applicant - Rak Eun Choi 1685 Donegal Ct Eagan MN 55122 (651) 248-7241 Home Energy Center 2415 Annapolis Lane N #170 Plymouth MN 55441 (763) 476-1990 Applicant/Permitee: Signature Issued By: Signature PERMIT City of Eagan Permit Type:Plumbing Permit Number:EA167240 Date Issued:03/04/2021 Permit Category:ePermit Site Address: 1685 Donegal Ct Lot:10 Block: 1 Addition: Murphy Farm PID:10-49500-01-100 Use: Description: Sub Type:Residential Work Type:Replace Description:Standard Water Heater Meter Size Meter Type Manufacturer Serial Number Remote Number Line Size Comments:Carbon monoxide detectors are required within 10 feet of all sleeping room openings in residential homes (Minnesota State Building Code). Please call Building Inspections at (651) 675-5675 to schedule a final inspection. Fee Summary:PL - Permit Fee (WS &/or WH)$59.00 0801.4087 Surcharge-Fixed $1.00 9001.2195 $60.00 Total: I hereby acknowledge that I have read this application and state that the information is correct and agree to comply with all applicable State of Minnesota Statutes and City of Eagan Ordinances. Contractor:Owner:- Applicant - Rak Eun Choi 1685 Donegal Ct Eagan MN 55122 Farr Plumbing & Heating Llc 2525 Nevada Ave N #104 Golden Valley MN 55427 (763) 732-9497 Applicant/Permitee: Signature Issued By: Signature