Loading...
1688 Donegal CtCITY OF EAGAN f"W.311I'.EFY- S TERMINAL NCI: 949 DATE: 06/30/99 TIME: 0:3207 I1J NAME. R A ROT HOMES INC 12252 9220 1.688 1XNEGAL. CT 10.00 320 9001 :1688 DONEGAL CT 27:3.7`1 0273.75 3866 9379 BOB MWEGAL. CT 100.00 3422 9001 1688 1"10t1EGA1. CT 827.94 2276 9220 168£3 DONE:,GAL. CT 11033.50 344E 9001 :15£3£3 V NEiGM.. CT i.0.50 2015 9001 i6BG DONEGAL CT 0.50 3743 922.0 1688 DONEE!!... C:1 50.00 205 900 1. 1688 DONEGAL CT 7,:x.00 f 326H 9f?20 088 DONEGAL.. CT 4E,8,00 Cft11.i2476 ## CONTINUE. USER IDc NANCY 21 CONTINUE M'F ??k * ? * ?>cc ?k ? Yt ? ? ? W. ? *>K:t>K k %K ? k1><c>k ? ? k<1X>k 1k ? ?k>k>K #k< # ? k? kY?X:d X? XWKkkK Mk *k*Mk CONTINUE. CITY OF EAGA.N CASHTER'" S 'T'ERMINAL. NOr. 947 DATE„ 06/30/99 TIME: 0:30 08 ID NAME: R A KOT HOMES INC :3716 9220 1688 DONEGAL. CT 114.00 3713 9220 :1.x_,88 DONEGAL CT 50.110 3865 922£3 W88 DONEGAL f'..'T' 825.00 Total Receipt Amounts 41864.1.9 W12476 USER ID: NANCY *?X**%ek1*?k??k1?*?>#*?* ?C??/?k*?NC?C?%c#1k>k??%sX?X??#? _r ?$ 1999 BUILDING PERMIT APPLICATION (RESIDENTIAL) - CITY OF EAGAN G 3 / l 3830 PILOT KNOB RD - 55122 ? t O ? 4- (0 j ?o 0 651-681-4675 New Construction Requirements Remodel/Repair Requirements ? 3 registered site surveys showing sq. H. of lot, sq. ff. of house and all roofed areas (20% maximum lot coverage allowed} 2 copies of plans (show beam S window sixes; poured fnd, design; etc.) 9 1 set of energy calculations 3 copies of tree preservation plan R lot platted after 7/1/93 DATE: to 11 I0(9 DESCRIPTION OF WORK: S I "`A Lc _. STREET ADDRESS: 1110 LOT: 5? BLOCK: I SUBD./P.I.D. #: Name: f\ (C?? Phone #: /o- t? OD-7 -?1`2 Last First PROPERTY OWNER Street hys Fay City State: A4 A Zip: s ?/ Z Company: _62 • A • f 6 1 6?S Phone #: (-%!?( C &7--• 9 y/3 (area code) CONTRACTOR Street Address: S 0 License# t?6 Exp. ;1006 City smil) It V,tA? State: /n Zip: S?l? ARCHITECT/ t ENGINEER Company: ' ? • S 1 h Name: , JCt y A Telephone #: area code-( ('v 6 % I ^4S 13 Street city Registration #: State: Zip: Sewer & water licensed plumber (required for new construction only): \d lFA,% i-L Mf ( -a4g J (, c ? -A rj, '-- Pihaity applies when address change and lot change Is requested once permit is issued. I her¢ .y,acknowledge tt at?l hay re _ d this application, state that the Information Is correct, and agree to comply with all applicable State'9licli'ates Minnesota Stafutes-and' ity' f Eagan Ordinances. k9a Signature of Applicant: OFFICE USE ONLY Certiof Survey Re'celve Yes No Tree Preservation Plan Received - Yes No /Not Required 2 copies of plan 1 set of energy calculations for heated additions 1 site survey for exterior additions & decks CONSTRUCTION COST: ate, OQ C3 New ( c^AnKT?Ir.? r ?lvrn Z 8Y-A s -t' `l JInV J OFFICE USE ONLY BUILDING PERMIT TYPE ? 01 Foundation ? 06 4-plex ? 11 10-plex ? 16 Fireplace ? 21 Porch (3-sea.) % 02 SF Dwelling ? 07 5-plex ? 12 12-plex ? 17 Garage ? 22 Porch/Addn. (4-sea.) ? 03 1 of _ plex ? 08 6-plex ? 13 16-plex ? 18 Deck ? 23 Porch (screened) ? 04 2-plex ? 09 7-plex ? 14 Apartments ? 19 Lower Level ? 24 Storm Damage ? 05 3-plex. ? 10 8-plex ? 15 Lodging ? 20 Pool ? 25 Miscellaneous WORK TYPE 1, 31 New ? 35 Tenant Impr ? 39 Gas Line Only ? 43 Siding/Soffits/Fascia ? 32 Addition ? 36 Move Bldg. ? 40 Gas Insert ? 44 Windows/Doors ? 33 Alteration ? 37 Demolish Bldg.' ? 41 Wood Stove ? 45 Fire Repair ? 34 Repair ? 38 Demolish (Interior) ? 42 Reroof " Give PCA handou t to applicant for demolition permit GENERAL INFORMATION Const. (Actual) (Allowable) UBC Occupancy Zoning # of Stories Length Width APPROVALS Planning 5 • t? Basement sq. ft. 351 V.F. ( Census Code (t? 1 5 • nI Main level sq. ft. ( (.- 2 SAC Code 011, R • 3 Ae , sq. ft. q oq No. of Units R I sq. ft. 100 No. of Bldgs _ sq. ft. MC/ES System sq. ft. City Water 5$ • 4'? Footprint sq. ft. - _ Booster Pump PRV Fire Sprinklered Building Engineering Variance Permit Fee Surcharge Plan Review License MC/ES SAC City SAC Water Conn. Water Meter Acct. Deposit S/W Permit S/W Surcharge Treatment PI. Park Ded. Trails Ded. Other Copies Total: SAC Units Valuation: 351 X 1,5 = 12 go, 4 1'c 25 $' lSofaao- 5 *5- 16 T7 IoU.? x 64= g1,(03d `Coll cC tlr = 14 , 544 ° o ( $o +t 'moo = S?{-oo Trrral 0 G7 % SAC EXTERIOR ENVELOPE AVERAGE "U" COMPUTATION OWNER MATHEIS, JOE & JEANNE PLAN NO. 9-0504-9 SITE ADDRESS LOT 5, BLOCK 1, MURPHY FARM CONTRACTOR: R.A. KOT HOMES, INC. DATE 06/08/ 9 PHONE 651-687-9 OETERMIME WORKING SQUARE FOOTAGE 2971.643' 1. Total exposed wall area305O.475 sq.ft. x .11 335.5523 2. Total roof/ceiling area 1736 sq.ft x .025 45.136 3. Total floor cant. area 7.5 sq.ft. x 0. 5 0.375 ,. (over unheated enclosed areas) 4. Total floor cant. area 226.67 sq.ft. x 0.02 5 5.66675 (over unheated exposed areas) j 5. Total exposed wall area above the floor. 2763.983 a. Total wall window area ................. :.. 353.71 b. Total door area ........................... 55.6278 c. Total sliding glass door area ............. 80.04 d. Total fireplace area .... ...............:.. 0 e. Total wall framing area (ave. 10%)........ 276.39B3 f. Total net wall area above the floor....... 1998.207 g. Total rim joist area ....................... 207.66 TOTAL EXPOSED FOUNDATION AREA .............. 1.. 78.8322 h. Total foundation window area.............. 0 i. Total net foundation area ................. 78.8322 Determine "U" value of each wall 4egment. a. 353.71 x "U" 0. 9 = 137.9469 b. 55.6278 x "U" 0. 6 = 3.337668 C. 80.04 x "U" 0. 5 = 28.014 d. 0 x "U" 0 = 0 e. 276.3983 x "U" 0.1034113 = 28.58307 f. 1998.207 x "U" 0.045998 = 91.91383 9. 207.66 x "U" 0.043141 = 8.958585 h. 0 x "U" 0.39 = 0 1. 78.8322 x "U" 0.073638 = 5.805022 6 ......:....::.......................Total 304.5591 If item #6 is the same as or less than item #1 you have met the current energy codes. 2 MCAR 1.16008 A AND O. TOTAL EXPOSED ROOF/CEILING AREA J. Total skylight area ....................... k. Total flat roof/ceiling framing area...... 1. Total net flat roof/ceiling area.......... Determine "U" value for each roof? clg J. 0x ful 10= k. 173.6 x "U" 0.0255 9 = 1. 1562.4 x "U" 0.02180 1 = 1736 0 173.6 1562.4 segment 0 4.43536 34.06148 7 ...................................Total ( 38.49684 If item #7 is the same as or less than item #2 you have met the energy code. 2 MCAR 1.16008 A AND 0. TOTAL FLOOR CANT. AREA (enclosed). 7.5 o. Total floor cant. framing area (ave. 10%). 0.75 p. Total net insulated floor/cant. area...... 6.75 Determine "U" value for each floor/cant. segment. 0. 0.75 x "U" 0.042863 = 0.032147 p. 6.75 x "U" 0.018265 = 0.123423 8 .......:...........................Total 0.15557 If item #8 is the same as or less than item #3 you have met the energy code. 2 MCAR 1.16008 A AND 0. TOTAL FLOOR/CANT. AREA (exposed) 226.67 q. Total floor/cant. framing area (ave. 10%). 22.667 r. Total net insulated floor/cant. area.... 204.003 Determine "U" value for each floor/cant. segment. q. 22.667 x "U" 0.035932 = 0.814481 r. 204.003 x "U" 0.016895 = 3.446579 . 9 ...................................Total 4.26106 If item #9 is the same as or less than item #4 you have met the energy code. 2 MCAR 1.16008 A AND 0. 1 I HERESY CERTIFY THAT I HAVE CAL E THE "U" FACTORS AND "R" VALUES HEREIN AND THAT THE BU LDING HERE D SCRIBED EETS OR E?CCEEDS THE STATE OF MINNESOTA ENERG CONSERVATirM CT. / s a ANSWER THESE QUESTIONS ABOUT THE STRUCTURE. (in the case of windows and doors, round up to next foot.) 1. 2. 3. 4. 5. 6. 7 8 9 10. 11. 12. 13. 14 15 16 17 WHAT IS THE TOTAL LIN. FT. OF SECOND FLOOR RIM JOIST?...... WHAT IS THE TOTAL LIN. FT. OF FIRST FLOOR RIM JOIST?........ HOW MANY LIN. FT. OF 1ST. FL. RIM HAS PARTIAL W/O BELOW?... HOW MANY LIN. FT. OF 1ST. FL. RIM HAS FULL W/O BELOW?...... WHAT IS THE TOTAL INSULATED CEILING SQ. FOOTAGE?........... HOW MANY PANES OF WINDOW GLASS ARE THERE? ...... 11 ........... 6A. HOW MANY 21 HIGH? ..............Transoms Averaged. 6B. HOW MANY 3' HIGH? ................................ 6C. HOW MANY 41 HIGH? .............................. 6D. HOW MANY 5' HIGH? .............. Transo s Averaged 6E. HOW MANY'61OR MORE HIGH? ......................... HOW MANY 3FT. EXTERIOR DOORS ARE THERE? .................... HOW MANY 218" EXTERIOR DOORS ARE THERE?. ................... HOW MANY SL. GLASS DRS. OR ATRIUM DRS. ARE THER AT: ........... 9A. 5'0" ................................. 9B. 6'0" .............................................. 9C. 710" ............................................. 9D. 8'0"..................................!........... 9E. 9'0" ............................................. WHAT IS THE SQ. FOOTAGE OF SKYLIGHTS? ...................... WHAT IS THE 1ST FL. SQ. FOOTAGE? ........................... WHAT IS THE SECOND FLOOR SQ. FOOTAGE? ...................... WHAT IS THE 1ST FLOOR CEILING HGT.? ...............AVG...... WHAT IS THE 2ND FLOOR CEILING HGT.? ........................ WHAT IS THE TOTAL ENCLOSED CANT. SQ.FT ..................... WHAT IS THE TOTAL EXPOSED CANT. SQ.FT ...................... WHAT IS THE TOTAL FOUNDATION WINDOW AREA ................... 0 207.66 12 78 1736 39.5 10.5 1 7 15 6 1 2 0 0 2 0 0 0 0 1697 0 9.58 0 7.5 226.67 '0 DETERMINE "U" VALUES" THRU STUD WITH SIDING & S.R. Interior-Air...... 0.68 Sheet Rock..::.... 0.45 Thermo-Break...... 0 Stud .............. 6.93 Shthng(Oxboard)... 0.66 Siding............ 0.78 Exterior Air...... 0.17 Total "R" Value..... ....... 9.67 1/R = "U" Value ..... ....... 0.103413 THRU INSULATION WITH SIDING & S.R. Interior Air...... Sheet Rock........ Thermo-Break...... Insulation........ Shthng(Oxboard)... Siding............ Exterior Air...... 0.68 0.45 0 19 0.66 0.78 0.17 Total "R" Value............ 21.74 1/R = "U" Value ............ 0.045998 THRU CEILING MEMBER Interior Air...... 0.68 Sheet Rock........ 0.58 Ceiling Member.... 4.35 Insulation........ 32.92 Still Air......... 0.61 Total "R" Value............ 39.14 1/R = "U" Value ............ 0.025549 THRU CEILING INSULATION Interior Air...... 0.68 Sheet hock........ 0.58 Insulation........ 44 Still Air......... 0.61 Total "R" Value............ 45.87 1/R = "U" Value ............ 0.021801 THRU CONCRETE BLOCK Interior Air...... conc. Blk......... Insulation........ Sheet Rk. (opt.). Exterior Air...... 0.68 1.28 11 0.45 (Add 0.45 0.17 Total "R" Value............ 13.58 1/R = "U" ..................0.073638 THRU RIM JOIST Interior Air...... 0.68 Insulation........ 19 Rim Joist......... 1.89 Shthng(Oxboard)... 0.66 Siding............ 0.78 Exterior Air...... 0.17 Total "R" Value..... ....... 23.18 1/R = "U" ........... ..... 0.043141 U" value for window........ U" value for doors......... U" value for Patio Drs..... THRU CANT. @ MEMBER (enclosed) (Assumes 9 1/2" LPI Joists) Interior air...... 0.68 Finish Flooring... 1.23 Shthng(Oxboard)... 0.66 Plywood........... 0.93 Joist(W/2x6 Furr). 18.64 Sheet Rock........ 0.58 Still Air......... 0.61 0.39 0.06 0.35 Total "R" Value............ 23.33 1/R = "U" ..................0.042863 THRU CANT. @ INSULATION (enclosed) (Assumes 9 112" LPI Joists) Interior Air...... Finish Flooring... Shthng(Oxboard)... Plywood........... Insulation........ Sheet Rock........ Still Air......... 0.68 1.23 0.66 0.93 50 0.58 0.61 Total "R" Value............ 54.69 1/R = "U" ..................0.018285 THRU CANT. @ MEMBER (exposed) (Assumes 9 1/2" LPI Joists) Interior Air...... 0.68 Finish Flooring... 1.23 Underlayment...... 0 Plywood........... 0.93 Joist(W/2x6 Furr). 18.64 Shthng(3/4" RMAX). 5.4 Soffit........... 0.78 Exterior Air...... 0.17 Total "R" Value.... ........ 27.83 1/R = "U" .......... ........0.035932 THRU CANT. @ INSULATION (exposed) (Assumes 9 1/2" LPI Joists) Interior Air...... 0.68 Finish Flooring... 1.23 Underlayment...... 0 Plywood........... 0.93 Insulation........ 50 Shthng(3/4" RMAX). 5.4 Soffit............ 0.78 Exterior Air...... 0.17 Total "R" Value............ 59.19 1/R = "U" ..................0.016895 ,i=. ar A LOT SURVEY CHECKLIST FOR RESIDENTIAL BUILDING PERMIT APPLICATION PROPERTY LEGAL: t c?T J ?LO?' e /? fQf Nj DATE OF SURVEY: LATEST REVISION: DOCUMENT STANDARDS -. c r - ? Registered Land Surveyor signature and company ? Building Permit Applicant ? ? - Legal description ? ? Address ? ? North arrow and scale v'? ? House type (rambler, walkout, split w/o, split entry, lookout, etc.) a" ? ? Directional drainage arrows with slope(gradient % ? ? Proposed/exisfing sewer and water services & invert elevation V ? p ? Street name n ? Driveway o? ? ? Lot Square Footage V O ? Lot Coverage ELEVATIONS Existln9 ? ? Sewer service (or Proposed) ? Property comers 0 ? Top of curb at the driveway ? ? Elevations of any existing adjacent homes Er ? ? Adequate footing depth of structures due to adjacent utility trenches Proposed a? ? Garage floor ? ? First floor / ? ? Lowest exposed elevation (walkouVWndow) lr'? ? Property comers V ? ? Front and rear of home at the foundation R/ ? ? rah ? ? y ? ? ? ?? D/? ? M-11,1Z ? V? ? ? W ? PONDING AREA (if applicable • Easement One • NWL • HWL • Pond # designation • Emergency Overflow Elevation DIMENSIONS • Lot linewBearings & dimensions • Right-of-way and street width (to back of curb) Proposed home dimensions including any proposed decks, overhangs greater than 2', porches, etc. (i.e. all structures requiring permanent footings) • Show all easements of record and any City utilities within those easements • Setbacks of proposed structure and sidayard setback of adjacent existing structures Retaining wall requirements, Reviewed: March 1909 CRAIG) LDoPRW FM II CITY USE ONLY LOT 1l BL `- { RECEIPT #: 15 ! ??? A Q JJJ SUBD. N`?1i1 ?( [ Arm RECEIPT DATE: 1999 MECHANICAL PERMIT (RESIDENTIAL) CITY OF EAflAN 3830 PILOT KNOB RD EAGAN MN 55122 (651) 661-4675 Date: Complete this section only if you are installing HVAC in single family, townhomes or condos under construction and not owner /occupied • HVAC: 0-100 M B T U $ 30.00 ADDITIONAL 50 M BTU 6.00 • Gas outlets (minimum of one required @ $3.00 ea.) 3 CIO • State Surcharge: .50 3 C) sJ '. TOTAL: Complete this section only if you are remodeling, adding to, or repairing existing single family dwellings, townhomes, or condos. Please indicate if it is a new item, replacement item, or repair. New - Replacement Furnace Air exchanger, i.e. Vanee system, etc. Reminder: Call 681-4675 for inspections. Air conditioning Other $ 30.00 State Surcharge: .50 Total: $30.50 SITE ADDRESS: OWNT ER NAME: PHONE #: EYSTALLER NAME:?uh- cc?2 c L (? a K e `f? ??Z PHONE #: 6,?-OV o0o f- STREET CITY: 1'- F1 'X JS/FORMS BLD/MECII PERMIT (RES) - 1999 - Repair _ Other _ STATE: z?'?-- ZIP: 76 SIGN?m---?4& L BL SUBD. APPROVED BY: RECEIPT M RECEIPT DATE: CITY USE ONLY INSPECTOR 1999 MECHANICAL PERMIT (COMMERCIAL) CITY OF EAGAN 3830 PILOT KNOB RD EAHAN, MN 55122 (651) 6$1-4675 Please complete for: all commercial/industrial buildings multi-family buildings when separate permits are not required for each dwelling unit DATE: CONTRACT PRICE: WORK TYPE: NEW CONSTRUCTION INTERIOR IMPROVEMENT DESCRIPTION OF WORK: FEES: 1% of contract price OR $30.00 minimum fee, whichever is greater. Processed piping - $30.00 CONTRACT PRICE x I% PROCESSED PIPING PERMIT FEE STATE SURCHARGE ($.50 per $1,000 of nermn fee due on all permits.) TOTAL SITE ADDRESS: OWNER NAME: TENANT NAME (IMPROVEMENTS ONLY): INSTALLER: ADDRESS: CITY: PHONE #: PHONE #: STATE: ZIP: 4 SIGNATURE OF PERMITTEE CITY USE ONLY L BL SUBD. hur OhJw vy\ RECEIPT #: 116`+' q (,7 RECEIPTDATE: 6-15-1q PERMIT# 3gotd 1999 PLUMBING PERMIT (RESIDENTIAL) CITY OF £AeAN 5830 PILOT KNOB RD EAGAN, MN 55122 (651) 681-4675 Please complete for: > single family dwellings > townhomes and condos when permits are required for each unit > backflow preventer for underground sprinkler system FIXTURES EACH # TOTAL R3+h hlh Y Floor drain 3.00 x $ -00 Gas piping outlet " minimum - t 3.00 x = $ v.60 Hot tub/spa 3.00 x = $ Kitchen sink 3.00 x $ Laundry tray 3.00 x $ 3.00 Lavatory 100 x Ys-60 Minimum fee alterations to existing dwelling 30.00 x = $ Private Disposal System new/refurbished ' requires MPC Nc. 75.00 x = $ Private Disposal System abandonment 30.00 x = $ RPZ new installation/re air 30.00 x = $ Rough opening 1.50 x = $ ,0 Shower 3.00 x = $ 3.00 Underground srinkler if dwelling is under construction 3.00 x = $ Under roundsprinkler if existing dwelling 30700 x = $ Water closet 3.00 x 3 = $ 9.00 Water heater 3.00 x = $ 3.00 Water softener if dwelling under construction 5.00 x = $ Water softener if existing dwelling 30.00 x = $ Water turnaround 30.00 x ---- _ $ State Surcharge .50 > > > $ 50 Total > > > > $ 5-Ro"rs,nder: '-a!! for !nsnectic:is of alterations, --. vwater heaters, water softeners, etc, - I h-----ereb--yacknowledge a6wolm--'-- th-'at_I thi- h6--------ave read ---s- s--.tat-e that the in ---- to- -comply -. application, fo rmati on is correct, and-agree with all applicab le Ci ty of Eagan ordinances. It is the applicant's responsibility to notify the property owner that the City of Eagan assumes no liability for any damages caused by the City during its normal operational and maintenance activities to the facilities constructed under this permit within City property/right-of-way/easement. SITE ADDRESS: OWNER NAME:: Q, yl xin? TELEPHONE #: 69/ 0092 - 06:30 (AREA CODE) INSTALLER NAME: TELEPHONE M 6,5-1 565 -Z-Izo ??77 (AREA CODE) STREETADDRESS: STATE: lXn zip: za-66F ?I AUG 19 1999 ?. SIGNATLIE OF PE EE SUED. CITY USE ONLY j,BBL. / RECEIPT #: 1 `?1 O a- RECEIPT DATE: 1 1 - ' PERMIT # \? 5 1999 PLUM$INC PERMIT (RESIDENTIAL) CITY of EAraAiN 3630 PILOT KNOB RD EAGRAN, MN 55122 (651) 661-4675 Please complete for: > single family dwellings townhomes and condos when permits are required for each unit > backflow preventer for underground sprinkler system FIXTURES EACH # TOTAL Lath tUb avu x i = $ I Floor drain 3.00 x = $ Gas i in Outlet ' minimum -1 3.00 x = $ Hot tub/spa 3.00 x = $ Kitchen sink 3.00 x = $ Laundry tray 3.00 x = $ Lavatory 3.00 x = $ Minimum fee alterations to existing dwelling 30.00 x = $ Private Disposal System new/refurbished ' requires MPC tic. 75.00 x = $ Private Disposal System abandonment 30.00 x = $ RPZ new installation/re air 30.00 x = $ Rough opening 1.50 x = $ Shower 3.00 x = $ Underground srinkler if dwelling is under construction 3.00 x = $ Underground srinkler if existing dwelling 30.00 x = $ Water closet 3.00 x = $ Water heater 3.00 x = $ Water softener if dwelling under construction 5.00 x = $ Water softener if existing dwelling 30.00 x = $ Water turnaround 30.00 x = $ State Surchar a .50 > > ----> $ 50 Total --> > > ---,.> Reminder- CPil rr- }nG',4c`Ionc ^: nits-7? ' a__ ,. _?__-... .. ..iiv:..:, ..¢. Yv aacr Hatai&i 6, Yir'tliV'r' SUftenerS, etc. ___ ______ ____-information' --------- _--_____.-__-_______---- --__.--__ _ _._--_.-_..____.-__.________. I hereby acknowledge that I have read this application, staie that the is_ correct, _ _and agree-to comply with all appli_cable City of E_agan ordinances. It is the applicant's responsibility to notify the property owner that the City of Eagan assumes no liability for any damages caused by the City during its normal operational and maintenance activities to the facilities constructed under this permit within City property/right-of-way/easement. SITE ADDRESS: OWNER NAME: : INSTALLER NAME: _ TELEPHONE #: / _5? - (?r9 - D 3 3 (AREA CODE) J TELEPHONE #: 5;2 - Lb - D 633 (AREA CODE) STREET ADDRESS: % / 5U / J 3S can ??? kM 'rte - CITY: &O 2 " STATE: ZIP: 5 r?? 6zkz SIGNATUR F PE MITTEE * PIONG®R * ang Weer -t* ** LM91 wNVeTU?a . um ENILR LAND PLANNERS. I.ANDSCME ARCHITECTS 2422. Enterprise Drive +• t?: Mendota Heights, MN 55120 ? a..i (851) 881-19WFAX:88f=9488" E-mail: PIONEEROPRESSENTER.COM 625 Highway 10 N.E. Blaine, MN 55434 (812) 783-1880 FAX-M-1883 E-mail: PIONEER28PRESSENTER.COM Certificate of Survey for: R.A. KOT 1688 DONEGAL COURT DONEGAL COURT 910.6 N LOT AREA =34,097 SO. FT. HOUSE AREA =2,589 SO. FT. COVERAGE =7.69, 911'0 co HOUSE TYPE-,Z 5-JbYy a..ar PROPOSED SERVICE 1 910.0 INVERT ELEV.-901.00 9 ELEC. K91d 11 O? O? + CATV. ' 1 9 (909,1? 908.9G.B n o 0 BENCH MARK ?TE-t909 6 SERV. TOP OF PIPE- ' ELEV.=911.35 \ CATV•? 0 0 aj' I N 10 ra? °0 ao I BENCH MARK 9121 0 .82! I 10.0 ?L -TOP OF PIPE 762 -_-_ 911.0 517 ELEV.=911-84 110.4 021.67 Q 11.16 ?A, 11.7 0 R3 m\ }?0 1.008 _ 00 GARAGE 19 .67 12.83 \ \" I . $68 909.4 n v 14 0 19.33 N s? s? 907.21 0 C e? o ! PROPOSED 8.0 1 (VACANT) q?'1 p O ! I \HOUSE \ 1 I pp 26.0\ °o I o 0 1 903.87=' _. ° 8.00 -_---- 1 15 906.17 C TB?L3 904.6 10.r i X X )0 ! SALT FE-rlcE r C9ca, c) L - - - - - 901.6 1ZE4 usR ED 887.Os 9.36'14"E 59.1d?.?? DRAINAGE- & UTILITY -EASEMENT PER PLAT 892.9 Alp FES ry WATER ELEV.=891.8 5-25-99 AP- 2._! TREATMENT POND NWL=892.8 HWL=894.1 444 A^ O CliR N89'33'09"E 88.95 DEERWOOD DRIVE w g NOTE: PROPOSED GRADES SHOWN PER GRADING PLAN BY BRW NOTE: BUILDING DIMENSIONS SHOWN ARE FOR HORIZONTAL AND VERTICAL LOCATION OF STRUCTURES ONLY. SEE ARCHITECTUAL PLANS FOR BUILDING AND FOUNDATION DIMENSIONS. NOTE: NO SPECIFIC SOILS INVESTIGATION HAS BEEN COMPLETED ON THIS LOT BY THE SURVEYOR. THE SUITABILITY OF SOILS TO SUPPORT THE SPECIFIC HOUSE PROPOSED IS NOT THE RESPONSIBILITY OF THE SURVEYOR. NOTE: THIS CERTIFICATE DOES NOT PURPORT TO SHOW EASEMENTS OTHER THAN THOSE SHOWN ON THE RECORDED PLAT. NOTE: CONTRACTOR MUST VERIFY DRIVEWAY DESIGN. NOTE: BEARINGS SHOWN ARE BASED ON AN ASSUMED DATUM PROPOSED HOUSE ELEVATION LOWEST FLOOR ELEVATION: goy s TOP OF BLOCK ELEVATION: ?, 0 GARAGE SLAB ELEVATION: 9)3.G, TOB B LOOKOUT ELEVATION: WE HEREBY CERTIFY TO R.A. KOT THAT THIS IS A TRUE AND CORRECT REPRESENTATION OF A X 000.00 DENOTES EXISTING ELEVATION SURVEY OF THE BOUNDARIES OF: t 000.00 ) DENOTES PROPOSED ELEVATION - - - DENOTES DRAINAGE AND UTILITY EASEMENT LOT 5, BLOCK 1, MURPHY FARM DENOTES DRAINAGE FLOW DIRECTION DAKOTA COUNTY, MINNESOTA 0 DENOTES MONUMENT - 9 DENOTES OFFSET HUB IT DOES NOT PURPORT TO SHOW IMPROVEMENTS OR ENCHROACHMENTS, EXCEPT AS SHOWN, AS SURVEYED BY ME OR UNDER MY DIRECT SUPERVISION THIS 20TH DAY OF MAY, 1999. S*E: PIONEER ENG EEP. A. SCALE : 1 INCH = 40 FEET a /' i 1 4 1? C. Larson, L.S. Reg. No. 19828 6 97500.06 NJK r- 1 1 7 N * PION61 * and * 'Jf'1 _7 ':I 19.ie< N' ll P .i •.C f LAND PLVINERS• IANDSCAPE ARCHITECTS Certificate of Survey for: PROPOSED SERVICE INVERT ELEV.-901.00N, I I 908.9c.e. II, (9O, 2) a 1688 DONEGAL COURT DONEGAL COURT LOT AREA =34,097 SQ. FT. HOUSE AREA =2,589 SQ. FT. COVERAGE =7.6% HOUSE TYPE- 02 "Ibv y W-0, 0 B TOP ENCH OF PIPEMARK--- TEL. ELEV.=911.35 CATV. R.A. KOT ozo nlgnway w N.a. Blaine, MN 55434 (612) 783-1880 FAX 783-1883 E-mail: PIONEER20PRESSENTER.COM 910.6 N 911.0 AOO '0 9 ELEC. ?91d, 9JJ 1 CATV. )' • Z ?o oX! ?5 ? W o? r,? o I C7 911.01 110.4 C4133) 1 J 1 I PN ( t0 BENCH MARK 1 ,TOP OF PIPE 51z ELEV.=911.84 2.1 11.1 6 A? e 4)1= e.oa ?I ,2. a3 4 / \p? 19.33 N 909.4 (Atx9) n ?I M\\HOUO\EED 8.00 907. 1 0 (VACANT) ?0, O I 26.0 OD 903.871` I 11 _ _O -°1e'00, __ _ - - - 1 15 906.17 2 -f s 904.1 (90L),b)904.6 ,0.( x x / 70I I STLY FE'I'ICE C9e?, c) _L - - -990?1.6 REQ U-IRE.0 l 887.05 ,H,N89'36'14"E 59.1?T.M.ricjs /S DRAINAGES & UTILITY,, _EASEMENT PER PLAT 892.9 FES 4) 5 ti WATER ELEV.=891.8 5-25-99 AP- Z.1 TREATMENT POND N WL=892.8 HWL=894.1 11 Lea ?. t V ' & = T., 7PT t N89'33'09"E 88.95 DEERWOOD DRIVE NOTE: PROPOSED GRADES SHOWN PER GRADING PLAN BY: BRW NOTE: BUILDING DIMENSIONS SHOWN ARE FOR HORIZONTAL AND VERTICAL LOCATION OF STRUCTURES ONLY. SEE ARCHITECTUAL PLANS FOR BUILDING AND FOUNDATION DIMENSIONS. NOTE: NO SPECIFIC SOILS INVESTIGATION HAS BEEN COMPLETED ON THIS LOT BY THE SURVEYOR. THE SUITABILITY OF SOILS TO SUPPORT THE SPECIFIC HOUSE PROPOSED IS NOT THE RESPONSIBILITY OF THE SURVEYOR. NOTE: THIS CERTIFICATE DOES NOT PURPORT TO SHOW EASEMENTS OTHER THAN THOSE SHOWN ON THE RECORDED PLAT. NOTE: CONTRACTOR MUST VERIFY DRIVEWAY DESIGN. NOTE: BEARINGS SHOWN ARE BASED ON AN ASSUMED DATUM PROPOSED HOUSE ELEVATION LOWEST FLOOR ELEVATION: q0415 TOP OF BLOCK ELEVATION: 1 1 GARAGE SLAB ELEVATION: TOB 0 LOOKOUT ELEVATION: WE HEREBY CERTIFY TO R.A. KOT THAT THIS IS A TRUE AND CORRECT REPRESENTATION OF A X 000.00 DENOTES EXISTING ELEVATION SURVEY OF THE BOUNDARIES OF: ( ODO.00 ) DENOTES PROPOSED ELEVATION - - - DENOTES DRAINAGE AND UTILITY EASEMENT LOT 5, BLOCK 1, MURPHY FARM DENOTES DRAINAGE FLOW DIRECTION DAKOTA COUNTY, MINNESOTA - DENOTES MONUMENT $ DENOTES OFFSET HUB IT DOES NOT PURPORT TO SHOW IMPROVEMENTS OR ENCHROACHMENTS, EXCEPT AS SHOWN, AS SURVEYED BY ME OR UNDER MY DIRECT SUPERVISION THIS 20TH DAY OF MAY, 1999. SI E PIONEER ENG! EERIN , P.A. SCALE : 1 INCH = 40 FEET q f, B ,1 n7mnnna kIIV ED JUG 1 ""°° ohn C. Larson, L.S. Reg. No. 19828 RESIDENTIAL BUILDING PERMIT APPLICATION yql 7 L/ CITY OF EAGAN I / / 3830 PILOT KNOB RD - 55122 651-681-4675 New Construction Requirements • 3 registered site surveys showing sq. ft. of lot, sq. ft. of house; and all roofed areas (20%mazimum lot coverage allowed) • 2 copies of plan showing beam & window saes; poured found design, etc.) 1 set of Energy Calculations • 3 copies of Tree Preservation Plan if lot platted after 711193 • Rim Joist Detail Options selection sheet (bldgs with 3 or less units) DATE I -M - Lob 1 RemodetiRegair Requirements • 2 copies of plan 1 set of Energy Calculations for heated additions 1 site survey for exterior additions & decks 0 i MVqtly fimr r)-N ,170,0-0 CalW 1-110--1 Hyo VALUATION (EXCLUDING LAND) r (nlbb 0 . C )o JOB SITE ADDRESS ll00B Ikon-to a I t6itt + IF MULTI-FAMILY BUILDING, HOW MANY UNITS? 1 PROPERTY OWNER J ea -in i?p_ Ma l h2 15 TYPE OF WORK N?. \J Df P_ IL.. FIREPLACE(S) ?0 _1 _2 _3 APPLICANT W 1 t I tf 1,- P6VtS-1-n-t t+ eyt __ PHONE # ?{S Z - 44o - -n,(, ADDRESS Is Dlalo AyidLL(WLL4el,- Dy . SQ1?Aq(? ZIPCODE 553 78 PAGER # CELL PHONE # Iola-- 3 L8- 0942 FAX # 19111 $a.v-?byt, NIEW RESIDENTIAL BUILDING ONLY - FILL OUT COMPLETELY Energy Code Category _ MINNESOTA RULES 7670 CATEGORY 1 (check one) Residential Ventilation Category 1 Worksheet Submitted Energy Envelope Calculations Submitted MINNESOTA RULES 7672 New Energy Code Worksheet Submitted Plumbing Contractor: Phone Plumbing System Includes: Water Softener _ Lawn Sprinkler Water Heater _ No. of R.I. Baths No. of Baths Mechanical Contractor: Phone # Mechanical System Includes: _ Air Conditioning Heat Recovery System Sewer/Water Contractor: Phone # All above information must be submitted prior to processing of application. Fee: $90.00 Fee: $70.00 I hereby acknowledge that I have read this application, state that the information is co ct, and ogre to comp) with all applicable State of Minnesota Statutes and City of Eagan Ordinances. J By Signature of Applicant ?? /Y1125"Ch?J? C? Certificates of Survey Received _ Tree Preservation Plan Received - Not Required _ Updated 1/01 OFFICE USE ONLY ? 01 Foundation ? 02 SF Dwelling ? 03 01 of_ plex ? 04 02-plex ? 05 03-plex ? 06 04-plex ? 07 05-plex ? 13 16-plex ? 08 06-plex ? 16 Fireplace ? 09 07-plex ? 17 Garage ? 10 08-plex *18 Deck ? 11 10-plex ? 19 Lower Level ? 12 12-plex Plbg_Y or _ N ? 20 Pool ? 21 Porch (3-sea.) ? 22 Porch/Addn. (4-sea.) ? 23 Porch (screened) ? 24 Storm Damage ? 25 Miscellaneous ? 30 Accessory Bldg ? 31 EM. Alt - Multi ? 33 Ext. Alt - SF ? 36 Multi ill Y 31 New ? 35 Int Improvement ? 38 Demolish (Interior) ? 44 Siding ? 32 Addition ? 36 Move Bldg. ? 42 Demolish (Foundation) ? 45 Fire Repair ? 33 Alteration ? 37 Demolish (Bldg)' ? 43 Reroof ? 46 Windows/Doors ? 34 Replacement *Demolition (Entire Bldg only) - Give PCA handout to applicant Valuation 2 C2 IV Q Occupancy MC/ES System Census Code `i! Zoning R._ City Water SAC Units / Stories Booster Pump Nbr. of Units Sq. Ft. PRV Nbr. of Bldgs Length Fire Sprinklered Type of Const S Width REQUIRED INSPECTIONS Footings (new bldg) Final/C.O. - Footings (deck) Final/No C.0- - Footings (addition) _ Plumbing _ Foundation _ HVAC _ Drain Tile Roof _ Ice & Water _ Final _ Other - Framing _ Pool _ Ftgs _ Air/Gas Tests _ Final - Fireplace _ R.I. -Air Test -Final - Siding Stucco _ Stone - Insulation - Windows (new/replacement) ' .. Approved By /motto , Building Inspector Base Fee Surcharge Plan Review MC/ES SAC City SAC Water Supply & Storage S&W Permit & Surcharge Treatment Plant Plumbing Permit Mechanical Permit License Search Copies Other Total      ñ  þ    û ÿþýþü ÿÿ þ ýõý     üþþÿÿ ð   ô ùæ øþ ñ ë  ÿø  û ú ùð î  ú ù  ðùþ   ß Ýäþ þý î îï ùþ  âý ûá þ  òæ  ù  ùù  òþüæ þ ñ ñæ ù õãþþ þòþ þ ç  ÿ   þ þùþ  ò ù ç îþ ñ÷ þ  á   þõ ýòþñ æñ ç þ øèÞèçç ÷ü  û æþ èçëçìë àþ þüç  öúô ø óò ùùþ Þ úæñþ î  ÕÚûþ ý þî ÿþ þî ìíä þ ûù ýþ  òòþôöþ àýþ öàë êíéíìë æ  þõýæþæþå þæ þùùþþ þæþæò ñþ  þþý ñù õæþþùùþ ûþ òô þûþ  þî òÿþýþï þ ç ùùþã ñûýþ   ûýþ  PERMIT City of Eagan Permit Type:Plumbing Permit Number:EA135751 Date Issued:04/01/2016 Permit Category:ePermit Site Address: 1688 Donegal Ct Lot:5 Block: 1 Addition: Murphy Farm PID:10-49500-01-050 Use: Description: Sub Type:Residential Work Type:Replace Description:Water Heater Meter Size Meter Type Manufacturer Serial Number Remote Number Line Size Comments:Please call Building Inspections at (651) 675-5675 to schedule a final inspection. Carbon monoxide detectors are required within 10 feet of all sleeping room openings in residential homes (Minnesota State Building Code). Fee Summary:PL - Permit Fee (WS &/or WH)$59.00 0801.4087 Surcharge-Fixed $1.00 9001.2195 $60.00 Total: I hereby acknowledge that I have read this application and state that the information is correct and agree to comply with all applicable State of Minnesota Statutes and City of Eagan Ordinances. Contractor:Owner:- Applicant - % Jl Sargent Bobbys Place Llc 2705 Grassy Spring Place Las Vegas NV 89135 (651) 797-2798 Benjamin Franklin Plumbing 5718 International Parkway New Hope MN 55428 (612) 604-4285 X61 Applicant/Permitee: Signature Issued By: Signature EAGAN 3830 PILOT KNOB ROAD I EAGAN, MN 55122-1810 (651) 675-5675 I TDD: (651) 454-8535 I FAX: (651) 675-5694 Email: buildinginspectionsacitvofeagan.com Commercial Plan Submittal: eolansOcitvofeagan.com L For Office Use l Permit#:/// �p Permit Fee: 6j 'f ' d V Date Received: Staff: 2020 RESIDENTIAL MECHANICAL PERMIT APPLICATION Date: if.N Site Address: 1(6(Fe- Pc/K R.L CCi(.trfi Tenant: Suite #: (c Resident/Owner Contractor Permit Type Name: Al . w i. f Address / City / Zip: I (E kr" Pd n 24 ' C Name: ��t9.t c.w PC Address: 7 �/ pU•1.�-�a.� State: / 4\ Zip: 6-s-( a"U sCt Phone: License #: S' t —t° P L • City: /`%t. tie 'Fe- 6frir Phone: 4 S 1— Contact: QA"p` . Email: RESIDENTIAL Furnace 1 Air Conditioner _ Air Exchanger _ Heat Pump Other e14K c0 a R 2ct'- w1®t[(u, cat Type of Work New ✓ Replacement Additional Alteration Demolition Description of work: R a'( 4-svece c6 Ave 4. exage -k A/C._ RESIDENTIAL FEES $60.00 Minimum Add or alteration to an existing unit, includes State Surcharge I' $100.00 Residential New, includes State Surcharge = $ TOTAL FEE You may subscribe to receive an electronic notification from the City of proposed ordinances by signing up for an email update on the City's website at www.citvofeaaan.com/subscribe. I hereby acknowledge that this information is complete and accurate; that the work will be in conformance with the ordinances and codes of the City of Eagan; that I understand this is not a permit, but only an application for a permit, and work is not to start without a permit; that the work will be in accordance with the approved plan in the case of work which requires a review and approval of plans. Applicant's Printed Name7 X Applicant' gnature FOR OFFICE USE Required Inspections: Underground Rough In Air Test Gas Service Test In -floor Heat Final Reviewed By: Date: EAGAN 3830 PILOT KNOB ROAD I EAGAN, MN 55122-1810 (651) 675-5675 I TDD: (651) 454-8535 I FAX: (651) 675-5694 bu ildi nginspections(ir).citvofeaoan.com For Office Use Permit #: /e6 �6 Permit Fee: (`it)' 0 6 Date Received: Staff: �/ 2020 RESIDENTIAL PLUMBING PERMIT APPLICATION Dater/ 14/- O Site Address: MOFtt Pa ti ea ar C C O Le. r Tenant: Suite #: J CC Resident/Owner Name: M t4 Phone: Address / City / Zip: Set 6 Contractor Name: cTahG-C-cGY P1. "✓ S License#: ccf (~(4( Address: 14) U PGH/ ,. PC." City: Ale A CI -Cot 4`{]" p^ _ _ State: I'W\ Zip: 5-5-c.-1-v Phone: (aSI ^ {5 I .2—el., Contact: DA4P2— Email: cJ 64. . cr Q KAz- c.v?' & t+L1 #1 � cfrfi — Type of Work New Replacement Repair Rebuild Modify Space — Work in R.O.W. — — Description of work: ! wet. 'tom Description Tankless Water Heater Lawn Irrigation (_ RPZ / PVB) _ X Standard Water Heater Add Plumbing Fixtures (__ Main / Lower Level) _ Water Softener Description: Septic System Connection to City Water from Well New Abandonment RESIDENTIAL FEES $60.00 Water Heater, $60.00 Lawn Irrigation $60.00 New fixtures, $60.00 Septic System $100.00 New Residential $115.00 New Septic $60.00 Connecting to *Sewer & Water Water Softener, or Water Heater and Softener (includes State Surcharge) (includes State Surcharge) adding or removing piping (includes State Surcharge) Abandonment (fee collected with Building Permit) System (includes County fee and State Surcharge) City Water from Well* + $290 for Meter and $200 for Radio Read = $550 • Permit also required for connection charges 6 a` TOTAL FEES $ CALL BEFORE YOU DIG. Call Gopher State One Call at (651) 454-0002 for protection against underground utility damage. Cali 48 hours before you intend to dig to receive locates of underground utilities. www.gopherstateonecall.org You may subscribe to receive an electronic notification from the City of proposed ordinances by signing up for an email update on the City's website at www.citvofeagan.com/subscribe. I hereby acknowledge that this information is complete and accurate; that the work will be in conformance with the ordinances and codes of the City of Eagan; that I understand this is not a permit, but only an application for a permit, and work is noo start without a permit; that the work will be in accordance with the approved plan in the case of work which requires a review and approval of plan x Otkici I4QCf Applicant's Printed Name � x Applicant's J'nature Page 1 of 2