Loading...
1926 Covington LaneBUILDING PERMIT SF 77,000 N_ 11207 Receipt jk (:;'2'? // '?_ SiteAddress 1926 COVINGTON LN Erect ]p occuPancy R3 Lot 16 elock 3 aeclSub. BERKSHIRE PONDS Remodel ? Zoning R1 Percel No. nlame SONS CONSTRUCTION Address 4370 RAHN RD City EAGAN phone 452-4721 4c Name SAME Addresa ity Phone -?Z I Name ED MELICH x0 Address $522 LAKE ST ?W citv Phone 866-3800 I hereby acknowladge thot I have read this opplication and state fhaf fhe inlormafion is correct ond agree to comply with all applicoble State of Minnewto Stotutes ond Ciry oF a n =s. Sipnaturc of PermiMee ? A Buildiny Pennit is issued to: SONS ONSTRUCTION all work sFall be done in accordance with nll pMicable Stot ot Mi CITY OF EAGAN 3630 Pilot Knob Road, P.O. Box 21•199, Eagan, MN 55121 PHONE: 454-8100 Repair ? TypeofConst. ?? AtldRion ? No, Stories T Move ? Length 49 Demolish ? Depth 48 Int Impr. ? Sq. Ft. Install ? Approvals Fees Assessment Woter 8 Sew. Police F+re Erp. Plonner Council Bidg. Off. 11/4/E APC Var Dete Permit S 3b4.UU suronarge 38.50 PlanReview _.182._O0 snc 5 2 r) -0 0 WaterConn. 500.00 WaterMeter 63.00 RoadUnit 280.00 Tr.PI. 132.00 Parks ' I CoPies O Total on tha exprc% cordifion thoo pofo $tatutes and City of Eapon Ordinancea. Buildirp O4Nda1 SEDGWICK HEATING & AIR CONDITIONING CO. 8910 WENTWORTH AVENUE SOUTH • MINNEAPOLIS, MN 55420 •(952) 881-9000 ADDRESS ` r"? Cb ?1 Ky1c,, L?Y 120`tiLJ OCCUPANT m I W i.. l? ?b SOLDBV MAKE Lf? SERIALNO. 171.1;6 w 7HERMOST T 1/ VALVE LIMIT ?7 LIMIT SETTING nh ? - FANSETTWG T,? /v?"?l PILOTTYPE?h'lJ IGNITIONMODEL PILOTTIMING • (IJL. PRESSURE 5K Q? INPUTCFH `? PERCENT COz PERCENTOz ?pb /?,D? `? STACKTEMP. igo PERCENT CO -QL- FORM 235 (flEV. 11B9) CITY _ OWNE INSTAI MODE INPUT VENT SIZE HEATING TEST RECORD JOB S6 7i-r TVPEOFLINER J-/ %wrSA l1 LINEF SIZE & ?Q'? FILTERS: SIZE/? T?1AL-G W - NUMBER ? WIIiWG -_rj?P LPQ"t'fb TEST TAG LIGHTMG INSL `- DATE TESTED COMPANY TESTING NAME OF TESTER FORMDISTRIBIfrION: WHITECOVY-JOBFIIE YELLOWWPY- CRV .t7,qI9uM ?T/2 z, F : r ,(° BUILDING PERMIT CITY OF EAGAN 3830 Pilot Knob Road, P.O. Box 21-199, Eagan, MN 55121 PH ON E: 454-8100 D?' 'lsi?' IMr000 111 11 2Q / Reteipt # Site Address Erect Lot Block sec/Sub. ? Remodel Parcel No. Repalr Addition W Name Move Z Address Demolish r Int l ? City Phone mp , . Install Z? Name v? Address City Phone F W Name U? Address tW City phone I hereby acknowledge thot I hove read this opplicotion ond stare that the informofion is torrect and agree to tomply with all opplicable ? ? ? ? ? 0 Occu pancy Zoning Type of Const. No. Stories Length Depth Sq. Ft. " Water & Sew. Pol ice Fire E?+p. Plonner Council Bldg. Off. ?..? F*es Permit Rurchamw Plan Review SAC Water ConrL Water Meter Road Unit State of Minnesota Statutes and Ciry of Ec9an Ordinances. APC I Parks Var. Date C?ies ? Sipnoture of Permittee Total h Bullding Pertnif is issued fo: on the exprcss condition Ihat oll work shall be done in uccordence with oll opplicable State of Minnesota Statutes ond City of Eoflen Ordinances, , Buildinp Official ' Pwmit No. Pormit Holdsr Dato Tslephone # PlumL%np H.V.A.C. U ENctrie Sokaner Inwection pate Insp. Other Footings 1 Footings 11 ? Foundatlon Framing ? a GL)4 Roofing 1 Rough Plbg. k? _ Rough Htg. 3 ? Insul. Fireplace Final Htg. Flnal Plbg. g Z 7 ?6 Finei C4rt/Oee. U>k CA Wator ??ibe Loeation: Well Sevvor Pr. Disp. J ? t? U ?- •PERMIT # r/ < • RECEIPT # DATE ,?,j CITY OF EAGAN MECHANICAL PERMIT 454-8100 MINIMUM RESIDENTIAL FEE - $10.00 + $.50 MINIMUM COMMERCIAL FEE - $20.00 + $.50 ? FEE .? S/C TOTAI. 1. Bldg. Type: Res ? Comm Inst 2. New A?- Add Alter Repair 3. Total Bid Price 4. Job Address L, -Z G°' el¢ r??n Lot ?•'n Block J Sec 7, 5. Owner.,_?,017'f 610 n 5 ? . 6. Contractor ,? ? Yi1 ? ri,? p (.l/R /,. ,Sf.0 JiJd , fk 7 {Name} (Sheat) (City) (Zlp) 7. Contractor Phone #,F &`? RESIDENTIAL HEATING - 0?_?U's -$24.0o. Each additional 50,000 BTU's or fraction -$6.00 RESIDENTIAL COOLING - 01-24,000 BTU's -$12.00. Each additional 6,000 BTU's or fraction -$6.00 MODIFICATIONS/ALTERATIONS -$10.00 minimum fee 4-5iEATING VENTILATING HOT WATER STEAM AIR CONO. eIR PIPING PROCESSED PIPING AIR HAND. EQUIP. ReFRIG. RES. GAS PIPING OUTLETS -$1.50 TANKS: L.P. UNDERGROUND OTHER COMM./IND. RATE - 1% OF TOTAL BID PRICE PLUS $.50 STATE SURCHARGE FOR EACH $1,000 OF FEE. Signed: for Approved Inspections: Date Rough Insp. Date Final Insp. Reoeipt PLUMBING PERMIT Parmit No. ? CITY OF EAGAN Fee I Fil1 in numbered spaces S/C Type or Prin[ IeyiWy Tot 1. Date 2. Installation Cost 3. Job Address Lot ` Blk. Tract 4. Owner I 5. Contractor ` Phone 6. Address - , 7. City ? State 2ip 8. 8uilding Type: Residential 0 Commercial ? Institutional O 9. Work Description: New D Add O Alter O Repair 0 10. Describe i I 11. No. Fixtures Water Closet No. Fixtures C l/D i fi ld Bath tubs esspoo ra n e tic T Se k Lavatory p an Sottner Shower Well Kitchen Sink Urinal/Bidet Oth Laundry Tray er Floor Drains _ Drinking Ftn. Slop 5ink Gas Piping Outlets 12. I hereby certify that the above information is true and correct, and I agree to comply with all ordinances and Codes governing this type of work. Signad : for Rouyh f inal Inspectians: Date Insp. Date Insp. This is your permit when numbered and approved. Approved CITY OF EAGAN 464-8100 CITY OF EAGAN Remarks Addition BERKSHIRE PONDS Owner Street 1926 Covington Lane 10 13750 160 03 Improvement Date Amount Annual Years Payment Receipt Date STREETSURF. i 1982 239.09 23.91 10 STREET RESTOR. 123-80 8-99 15 GRADING SAN SEW TRUNK 1982 1](.04 11.74 15 SEWER LATERAL 1982 57.24 3.82 15 * 8 53 WATERMAIN 1 19$2 46.09 3.07 15 ?c WATER LATERAL WATER AREA 1982 176.04 11.74 15 STaRM SEW TRK STORM SEW LAT CURB & GUTTER ' SIDEWALK STREET LIGHT Roa Unit $280.00 1174785 WATER CONN. SUILDiNG PER. 11207- SAC 525.00 PARK _. : ? ? . _. _ INSPECTION RECORD CITY OF EAGAN PERMIT TYPE: 3830 Pilot Knob Road Permit Number: ?6;`' Eagan, Minnesota 55122-1897 Date Issued: (612) 681-4675 . , i.? SITE ADDRESS: APPLICANT: rN6 rI) h I Aar PERIUIIT SUBTYPE: TYPE OF WORK: • ? ? i?; il INSPECTION . DA g -66 . DA { i-t 1,+ARk'-;- Pl.AN RFVtr.wE1) RY 811 !. nDnMfs F L Permit Holder Date Telephone N PLUMBING HVAC Inspection Date Insp. Commenta FOOTINGS FOUND FRAMING ROOFING ROUGH PLUMBING PLBG AIR TEST ROUGH HEATING GAS SVC TEST INSUL GYP BOARD FIFIEPLACE FIREPLACE AIR TEST FINAL PLBG FINAL HTG ORSAT TEST BLDG FINAL DOMESTIC METER IRRIGATION METER FLUSH MAINS CONDUCTIVITY TEST HYDROSTATIC TEST BSMT R.I. BSMT FINAL DECK FTG -?v DECK FINAL / CITY OF E AGAN WATER SERVICE PERMIT 3830 Pilof Knob Road ; 1'. O. Boac 21199 PERMIT NO.: E EagSh, MN 55T DATE: Za+i^g: - No. of Units: ? ? 'pwrwr; Sons Construction Addross: ?Site Add,ess: ?936 G6via??ton Lar.e I] F 133 Berkahire Ponds , Plumber. Plu±7b 4 wom e j Mater No.: 3<o .5+ 5/ S3 / wftM& Charpe: 500, f)Opd ? srze: 5/s Ro ? i?s Be#o? ???es i?•'?t?rd ? rreaae, No.: raM %W#RW-GVSEtc 10.00pa ? 1 pm to oompyr wNb !MG? y i Odiw? K??i V ?Sy?h 5 i1 rid IR UI.M . 132 . OJpd iP ? . Totoi: 63.102d '_?teter I BY Dote Paid: I nop.: CITY OF EAGAN SEVM SERV 3830 Pilot Knob Rosd ICE PERMIT P. O. Box 21199 PERMIT NO.: Eagan, MN 55j;1 p^TE; Icrinp NO. af Units: ?;_+.+1;= Ownar: - .. . _ . ..: : Address: Site Address: Plumber: 1 pm te eony* wilh !M Qhr ef Eqa¦ Ordiwnoa. ey Dcte af lenp,: Connectlan Choros: Accaunt Deposit: Par?nit Fea: Surchorye: Misc. CFrorqm Total: Doh Pold: PERMIT CITY OF EAGAN 3B30lilat Knob Road Eagan, Minnesota 55122-1897 (612) 681-4675 PERMITTYPE: BuzLorNe Permit Number: 0 3 2 3 5 5 Date Issued: 0 6/ 2 6/ 9 8 SITE ADDRESS: P.I.N.: 10-13750-160-93 1926 COVINGTON LANE LOT: 16 BLOCK: 3 BERKSHIRE PONDS DESCRIPTION: B,ytrilding;; Permit Type B'uilding Wq;rk Type -Census Code"'\ , DECK NEW 434 ALT. RESIDENTIAL ' t t L `:l r REM?RP:REVIEWED BY BZLL ADAM5 FEE SUMMARY: Base Fee $50.00 Surcharge $.50 Total Fee $50.50 CONTRACTOR: OWNER: - Applicant - GIBBONS MIKE 1926 COVINGTON LANE EAGAN MN 55122 (612)406-1097 ' I hereby acknowiedge that I'have read this , infqrmation ie oo!rrecC and agree to comply Statutes and City of Eagan OrdznanGes. APPLICANTlPERN1 E SIGNATURE application and state t'hat the wit'h all applicable State of Mn. ? ? UED BY: SIGNAT RE ?('? ? 1998 BUILDING PERMIT APPLICATION (RESIDENTIAL) 0,Cjb ? CITY OF EAGAN 3830 PII.OT RNOB RD - SS ? 32 ? 681•4675 pr`s. fta. New,ConstruUion Reaui2ments Rem URe air R uire?nts N ?ialip! bl . .? - .- 0 3 registered site surveys ? 2 cop f lan ? 2 copies of plans (include beam 8 window sfzes; poured fid. tlesign; etc.) ? 2 stte surveys (extior adddions & Cecl ? 7 energy wlwlations ? 1 energy ntculation. heated ad ' n • 3 copies of tree presenation plan H lot plat[ed after 7l1193 requirea: _ Yes No DATE: G- aa , Z r CONSTRUCTION COST; DESCRIPTION OF WORK: Y L C/( STREET ADDRESS: / q LOT: BLOCK: ? SUBD./P.I.D. Name: Cl I? rhN!? [- r CkC P6one #: '?0S_( 0 G_7 PROPERTY 1.est First OWNER 1 /Street Address:_ ? j d? ? y I City ? t 6-/q',,,v State: /11 Zip: CONTRACTOR Street Add City ARCHITECT/ ENGINEER Company:, Name: Street Add City _ Phone tt License # _ Stare: Zip: Phone #: Registration 1t: _ State: Zip: Sewer & water licensed plumber (new construction onry): . Penalty applies when address chang and lot change is requested once permit is issued. I hereby acknowledge that I have read this application and state that the information is correct and agree to comply with all applicabl State of Minnesota Statutes and Ciry of Eagan Ordinances. _' n rn _ A „ Signature ofApplicant / ` OFFICE USE ONLY LJ Certificates of Survey Received _ Yes _ No '02 2M 4A_ Tree Preservation Plan Received _ Yes _ No Not Required a , CITY Ot EAGAN 2 / O Q APPLIC:1TIvN FOR PER:tiIIT SELJER AND/OR WATER CONNECTIOr1 P RODERT!' ACDRE55: ? ? (PLEASE PfiiNi) y ? C? Q ' J'j l"/ / 1 ? _L_,h TF''?21,I. D'ASP'TZC:J: C ? CA /V i ( tB/S u:XuT?isicn or Tax Parcel I.D. Numerl sTRcc ILT:E , naT oF cRTIcLI;?L : Ur...D=:c =_-7.= zss,;;-Nc: PDF..CL.T =7T,vr:1'1:1:?0P0SJ L'S: ?;;-1 Si:= cP_MIILY - ? R-2 BU?'"{ (7%'0 LNI:S) ? R-3 'ICF,.???^L?SE (?'Y_°EE + L^]ITS) ( Wi ITS) 17 .-4 Ui;ITS) Q CCitiIES=:.C.L?2,/RE^'•AIZ,/OF:'IC : Q --N:: 1.;Si='eL Q T`..:STITTUTIONAL/GGVF..'?`AENT 2) A7n=2.? 1PLESJE 'flliiiJ . ? a N ST ADoPESs: CZZ"_', STA':'', ZIP: I 09 IId I? lT ,f 19' aj- PhONE. J j) plj,,.^E?, tiTZ' NP ('7? )A? /] ?,y?-' :Jf/ ryl?Yi J 6?1 ?7 T FOR CITY USE 04LY - : 1 , ? / ? PDD?ESS: ? ? ` 1 ? ? PLJHBERS E4SE: . CITY, STA?'E, ZIP: ? C /` l lJ , J??,?r• Active ? Ez ?r PHO?IE:Y -3C?: PIU:'BER LICENSE p F Record ? tI tntci 4) O=u'?=1 /CS,Z:E2 NkME• S 15? C ADDRESS: CI'I"l, STATL', ZIP: , PfiQ`IE: -, 5- 5} IIVDIG,TE "7FIICH PERi•IIT IS BEING RE?UE=: JE CO.+iVECPIO:] 'Ib CITY SE';•ir12 ? CO^&v'ECTZO:I 'IL7 CZTY S,iAT...'Tt U Vi1a?:R (PLPlLcZ D=;SBE) • ? P*.Y-`,SE f?OID r1PPPC7l,'ID P?'ST FOR PICi:-IIP BY ONE OF 11£GVE ?°LE-+Sc: ?7LIL APPDUtIp P=_•LLT T'J 1. 2. 3, 4 A&WE (Circle one) 7) SIC:?,TLTti.. j DATE, !!l aliiil/R.is i? +? d????ra ae : A o s?aa r?1 s ?isi:a:? a ia r? ?c:.?rsa ???? as¢a.ay . F O R C Z T Y U S E O N L Y Pfa`1IT " ZSSUED . rEES : $ /^ U $ /G S v $ 63 fl nr?.. / . ?.. _ITT lI,'.1.....:iL .? l.- WAT°3 PE3"lTm (T..G:.,. ? J _? ?UD:. GL WATEi2 MET°R/COPFER:?ORN/CL'TS= R;:.DE.R S WATER T.'-1P (INC:.i;DE CORPORnTION STOP) $ S::dcR TAP $ AC^OuNT D•:.P^SIT - S•i2 T?3 $ ?G? ... WaC $ S:z sAc $ TR[;VK [VAT°:2 ASSESS?::T $ TFci::Q?C SE:':: R ASSESS?::2iT 'S LATERAL bLi:'ct'T ^- T/T li`Ii( S?i:c:= , _ _ $ Li-1TLR'iL tSLNLi -_T/TDUNK $ ? ??ATER TREAT?E:?T PLA\T SLRCHa RGE . $ OTAER: $ TOT= . .. . .. • , $ - ?Go2. cC? AMOti`:T PAIDl3E?E':.-_ R DOcS UTI:,ITY CON.;ECTION REQUIP.E EXCaVATION IDI PU5L_TC RIGHT OF LVAY? ? YES IF YES, THE:: n"PERAIZT rOR :'7035 LdIiF?T?I PUBLIC ROAOI9AY" MUST Bv iS5[iE.r. BY TH? NO ENGI.IEERING DIVZSION. LIST .iiS A CONDI- TION, - SUBJECT TO TfiE FOLLOS4ING CONDITIONS: APPROVED BY: TZ':Lc: - DAT° : 2m aw Ei mw? .Em wc m .a wkm wtm w Mw +tir wrg stw wR-M w Ww 4.pv mtm N*W se W:p+ w?w mm M04 srn m m 1985 BUILDING PERHIT APPLICATION - CITY OF EAGAN NOTE: ALL CONTRACTORS NUST BE LICENSED WITH THE CITY OF EAGAN COl41ERCIAL SINGLE FATIILY DWELLINGS INCLUDE 2 SETS OF ARCHITECTURAL INCLUDE 2 SETS OF PLANS & STRUCTURAL PLANS, 1 SET OF 3 CERTIFICATES OF SURVEY SPECIFICATIONS AND 1 SET OF '1 SET OF ENERGY CALCULATIONS ENERGY CALCULATIONS $2,000 LANDSCAPE BOND To Be Site l-7 ,c'apo Used For: A/dh, e Valuation: 4;'z'-6fr?- Address ??2-6 C001A?6r4',r/ Z= OFFICE Lot /? Block 3 Parcel/Sub ?87h 1L$A/1/tN pA"t7Dt Owner Sb,UJ Co ASr2u.ur.c, u Address L/370 R-qkAJ IZrX City/Zip Code .TS/1 Phone `75 Z -'-/7 Z/ Contractor 50&-% CoNs7-h-ccr:r1e0 Address L(37c py (LtF' City/Zip Code E.¢(ep,J ('-r/yi Phone _4 f't - q7 LJ Arch./Engr. re,C Address O J L -,- 1-41t , ST City/Zip Code Phone a Date: Erect X Remodel ? Repair ? Addition Move ? Demolish Int.Impr. ? Install ? APPROVALS Oecupancy Zoning Type of Const II of Stories Length Depth Sq Ft FEES Assessments Permit Water/Sewer ' Surcharge Police Plan Review Fire SAC Engr Water Conn Planner Water Meter Couneil Road Unit Bldg Offll Treatment P1 APC Parks Variance Copies TOTAL ? \ SQ 2ox 4? =_, 1Z22 x ?08JG ZO X 22 - 1?40 n 12 = SZgo (cx7 x 8 - e3oo 7Co`l 5 & 41 , , EXTERIOR ENVELOPE AVERAGE "U" COMPUTATION OWIlIR: SITE ADDRESS: ?«lAr C-- Y ;.:iNTRACTOR: DATE: PHONE: DETERMINE WORKINf, SOUARE FOOTAGE OF EACH: TOTAL EXPOSED WALL AREA,,,,,,,, Ig'} (o gq ft x"U" .11 . 2?7•36 :. TOTAL ROOF/CEILING AREA,,,,,,,, ( 2 S¢ sq ft x"U" .026 i. TOTAL EXPOSED 1JALL ARE.4 CALCULATIONS: Total exposed wall area above floor,,,,,,,, sq ft a) Total wa11 window area: 4lazed...... I 3 2 sq ft x"U'' ,?j9 • $8 qlazed,,,,,, sq ft x"U" = q,ZO b) Total door area ,,,,,,,,, 40 sq ft x"U" •2 3 ° c) Total sliding glass door area: 9lazed...... 4o sq ft x"U" . S8 s 23.Zo qlazed...... Sq ft x "U" u d) Total flreplace wall area sq ft x "U" e) Tota) wall framing area (Averaqe 10)......... I?v ( sq ft x"U" .I O f) Total net wall area above ° 1("10 floor (Insulated)....... 1451 sq ft x"U" . a4 = S.04 q) 7ota1 rim Jotst area...... I S L sq ft x"U" . O 4 = !o , 0 8 Total foundatlon area (Exposed).......... sq ft h) Total foundatton window area............. sq ft x"U" ° t) Total net foundatlon area above grade........ sq ft x"U" ? i 9 7 ? , iTo,So TQTAL a) thru 1) If Item e; Is the same as, or less than item pi, you have met the intent of 2 :1CAR 1.16008 A and O. Page 1 4. TOTAL.EXPOSED ROOF/CEILINf, CALCULATIONS: Tota) exposed roof/ceitlnq area........ I ZS+sq ft J) Total skyilaht area....... sq ft x"U" k) Total roof/ceflinq framing 3.4 5 area (Average l?g)...... 1?_ sq ft x"U" . ? z?` '- I) Total oet lnsulated , 024 . 2??10 roof/cetlinq area....... I I"L 9 sq ft x"U" 4 TOTAL J) thru 1) 3° .55 If total of dh is the same as, or less than N2, you have met the intent of 2 MCAR 1.16008 A and 0. ALTERNATE BUILDINC. ENVELOPE DESIGN To utilTze the total envelope system method, the values established by the sum of items 93 and #4 shall not be greater than the sum of items pl and 02. 1. + 2. ° 3. + 4. ° C E R T 1 F I C A T I 0 N I hereby certTfy that I have calculated the "U" factors and "R" values heretn and that the Aulldinq here descrlbed meets ar exeeeds the State of Minnesota Enerqy tonservation Act. Siqnature (Date) P8$e 2 p ' ?•e ?.? -? A 'P.« e. A •?.Q• 1-* .• , Q:•q, :e•_' d-.f:: J;,4 NSTRUCTION R YALUE AMING SECTION: Interior air f11m 0.6A arywe ?? . . S otr S'/2 inc ett` soft w o o d Ce,12 sa+?e7uI uc, 2.o4 ?1D1NG • Z Exter or a r film TOTAL R ? Ia.iS U - 1/R - .1o WALL SECTION (INSULATED) -?1 Interior air film Pi tiG erior i u - 1/R - .04 RIM J015T SECTIDN: '1 Interior air ftlm 0.69 '2 tN -? uL- . 7 0.00 Il/l'' WOOD t.s8 4 SNYe GTH I6lG ?,OG 5 S?D?U4 6 Exterior air flm 0.17 TOTAL R - 25•4G FOUNDATION INSULATION REQUIRED: Min. R-5 on entire wall OR U ' I/R '. 0 4' Min. R-10 down to frost depth FOUNDATION SECTION: --{1 Interior air film O./,R r, 43 (4 (5 ?F Exterior a r iim 0.17 SLAA ON GRADE Unheated Slabs: Minimum R - 6.2 TOTAL R s U = 1/R - PAOP I CONSTRUCTION R VALUC• CEILINf, SECTIQN (INSULATEW 1 Interlor alr film O.hl AIR 2 V?tYWC?I -b(o CHUTE 3 .o a 4 Exterlor air film still ?•F1 TOTAL R - I . "18 u - 1/R - .oz4 F CEILINf FRAMINC, SECTION: 1 Intarlor air fllm ?•F1 Q 7?1?" pRYw.?LI iS?e 3 4 Interior alr lm still n. 1 5 FVz, 1 nches so t wooA 4, 3 6 TOTAL R U - 1/R n oZIG CEILING SEf,TION (INSULATED): 1' Interior air film ?•F) 2 3 4 Exterior air ilm stfl 6.61 TOTAL R s U0 i/R- __ VENTED CEILINr, FRAMIHf; SECTION: 1 Interior air fTlm 2 3 ? 4 Exterior air ?lm -,qT- S Inches soft wood TOTAL R U - 1 /R o .__ H 1 .Inside atr film nAl 2 3 5 Dutside air ?,m TOTAL R U- 1/R pA4P 4 GUIOELINE TO (R) FACTORS FROM ASNRAE MANUAL OF TYPICALLY USED PRODUCTS AIF FILMS iq SHEATHING (R)- Interior Air Film (Walls) 0.68 3/4" Wood Subfloor or Sheathing 0.94 62 0 Exterior Air Film (Walls) 0.17 1/2" Plywood Sheathin9 . 66 0 Irterior Air Film (Vented Ceiling) ) li 0.61 61 0 1/2" Particle Board ' Gypsum or Plaster Board 3/8 . 0.32 Exterior r i I t Air Film Air Film ng (Vented Cei (Non Vented) . 0.61 Gypsum or Plaster Board 1/2" " 0.45 er o n Exterior Air Film (Non Vented) 0.11 Gypsum or Plaster Board 5/8 " 0.56 47 0 Plywood 3/8 . Plywood 1/2" ? 6Z BLOWING WOOLS Plywood 3/4" Sheathing, Reg. Density 1/2" 0.93 1.32 FFprox. 3" 9.00 Sheathing, Re9. Density 25/32" 2.06 Approx. 4 1/2" 13.00 Nail-Base Sheathing 1/2" 1•14 Approx. 6 1/4" 19.00 Approx. 7 1/4" 24.00 Approx. 14" 30.00 ROOfS Approx. 18" 40.00 guilt-up Roofs 0.33 All other insula tion materials must Asbestos-Cement Shingles 0•21 be verified (R F actor) Asphalt Roll Roofing 0:44 Asphalt Shin9les INSULATION Insulation: 2-2 3/4" Fiber9lass 7,00 SIDING 61 0 insulation: 3 1/2" Fiberglass 11•00 Aluminum Siding . 1 82 Insulation: 6" Fiberglass 19.00 Aluminum with Backer iled R F • 2 6 Insulation: 3 5/8" Fiberglass 13.00 00 o Aluminum with Backer (Wood) Sidi ?:8 Insulation: 9" Fiberglass 30. ng 112 x 8 Lap 67 0 insulation: 12" Fiberglass 38.00 7/16 x 12 Hardboard Siding . 21 0 Insulation: 8" Cellulose 29•00 Asbestos Sidings 1/4 Lapped h Coat) i . ---- Insulation: 10" Cellulose 37.00 s Stucco (erown and Fin Insulation: 12" Cellulose 44.00 insulation: 1 1/2" Thermax 12•00 ? Insulation: 2" Thermax 16.00 DOORS 1 3/4" Solid Core Door .46 .,IOODS w/Storm, Wood •31 26 - w/Storm, Metal • Fir, Pine & Similar Soft Woods Pease Steel Door Insl/N/6L 7.45R .13 1 1/2 " 1'89 12 3 Sliding Glasr Door, Wood .65 2 112 . Metal .72 3 112" 4.35 5 1/2" 6.87 WINDOWS i.ONCRETE BLOCK R" Concrete Block (S 8 G Re9.) 1•11 All Windows (w/5torms 1" to 4" Soace) .56 (Filled with Vermiculite) 1.93 Removal Double Glazing (RDG) .55 12" Concrete Block (5 & G Re9.) 1•28 Thermo or Welded 3/16" Air Space .64 (Filled with Vermiculite) 3•15 1/4" Air Space .65 8" Light Weight 2.18 1/2" Air Space .58 (Filled with Vermiculite) 5.03 (Other windows specifically teste light Weight 12" p,48 can use better ratings) (Filled with Vermiculite) 5.82 Page 5 OVILUNHL UtSlUN METHUU ' As an,optlon to completing the Exterior Envolope Average "U" Computation where "U" values have to be calculated, the following method may be used. NOTE: All of the following six items must be accomplished in order to utilize this method. ??? I. Ceilings which meet one of the following criteria satisfy this requirement: A. R-38 throughout the entire ceiling. Indicate on plan section dr.awing how this will be accomplished. Complete appropriate diagram F, G, or H. B. If a portion of the ceiling is less than R-38, the insulation in the remainder of the ceiling must be increased to yield an overall average thermal resistance of not less than R-38. C. Where the roof at the perimeter of the ceiling prevents installation of insulation to full depth, the insulation in the ranainder of the ceilino must be increased to reduce the overall ceiling heat loss to no more than if R-38 had been installed throughout the entire ceiling. (Submit calculations if this method is used). _ on-? 2. For the insulated cavity of opaque wall and rim joists, but not foundation walls, a minimum R-20 is required. Canplete diagrams 6 and C. 00-0- 3. For the insulated cavity of floors of heated spaces over unheated spaces, , a minimum of R-20 is required. on-? 4. Maximum glass area may not exceed 12% of the area of exterior walls not including foundation walls. All windows shall be double glazed or have storm windows. Complete the following equation using data from the first page: 3(a) = 3(t) x x (x) must be less than .12 to meet requirements of this item. n?oo. 5. Maximum glass area may not exceed 10% of the area of exterior walls, not including foundation walls, when a sliding glass door is installed. All glass shall be double glazed or have storm windows. If sliding glass doors are to be installed, complete the following equation using data from the first page: t3(a) + 3(c3 ; 3(t) _ -77? _ y (y) must be less than .10 to meet requirements of this itan. no-0- E. A 1 3/4" metal faced door system with an insulated core providing an R value equal to or greater than 3.0 or a conventional door and storm. Ail primary doors must have durabte weatherstripping. Page 7 Mike Maguire MAYOR Paul 8akken Peggy Carlson Cyndee Fields Meg Tilley COUNCIL MEMBEPS Thomas Hedges CITY ADMINISTHATOR MUNICIPAL CENTEP 3830 Pilot Knob Road Eagan, MN 55122-1810 651.675.5000 phone 651.675.5012fvc 651.454.8535 TDD MAINTENANCE FACIIJTY 3501 Coachman Point Eagan, MN 55722 651.675.5300 phone 651.675.5360fax 651.454.8535 TDD www.cityofeagan.com THE LONE OAK TREE The symboi oi strength and growth in our community. June l, 2007 Michael Gibbons 1926 Covington Lane Eagan, MN 55123 Re: Corrections for your porch addition (Permit 469816) and deck (Permit #69209) Dear Michael: Enciosed are copies of conections for your porch addition and deck. These should help you when making the necessazy corrections for your upcoming re-inspections. If you have any questions or concerns, please feel free to contact me at 651l675-5683. Sincerely, J. Craig Novaczyk SeniorInspector Report Name: Clty Of EagdII Printed: 05/30/2 Inspection Remazks age: 1 Inspection Remarks Permit: EA069861 (PoQrJ+ "o rr Mrd) PermitType: Building `- 8/4/05 Footings TM -ok to pour center footing & SW comer 1 ll08/OS Frarning TM -no drip flashine over windows -shingles not installed per manufactured specs (drip edge, gable ends, not bonded out -at west end facia boazd where it meeu existing house not cut off and shingled over -ridge vent not installed per manufacture, -could not see step flashing om east end will need to verify -missing siding on west end -missing squash blocks at rim (between house & addition) DONE jtw -2x6 rafters under spanned, add another next to it -fireplace needs to be rated as a furnace, homeowner to provide specs. {N/A added heat runs} (see seperate Mech 71510 permit for new fiunace and A/C) t U25/OSJTW Insularion - complete prevoious frazning carrections - add ventilation shoots to every rafter space done tm - dbl up 2X6 rafter side by side and add a hanger or tail block at the ridge beam - uncover htg duct in the floor for inspec6on DONE jtw - add squash blocks at 2 locations (bearing for ridge beam next to the fireplace done hn DONE jtw and at the east wall of the addition {accesible in the bathroom ceiling at LL}) DONE jtw •** Call forreinspection ofventilation shoou before insulating ceiling'* DONE jtw - provide documentation of 1" of wood = R-1 for R-38 in the floor - 2 X12 rafter 16" OC OK, (plan called for 12" OC) 12/19/05 Insulation TM -upper insulated with vapor barrier, homeowner did not call for inspection of shoots. Checked 3 spots and shoou were at a113. - Missing blocking at west comer also no vapor barrier at same spot. Still need to do all corrections from above 12i27/05 JTW framing / insulation - OK to insulate ceiling - still need to dbl one 2X6 rafter next to existing house - to acheive R- 38 in the floor contractor may use R-24 batts in the 2X8 joist space and add2" of R-7 per inch rigid at the underside. at the heat runs use 1 layer of R-7 rigid between joists and below the heat run and add the same 2" of continous on the under side and leave the batts out. OR submit an altemate assembly. its% M "'?? ReP°rt Naz"e: City of Eagan Prinfed: OS/Pa e 2 Inspection Remarks B Inspection Remarks ? Permit: EA069861 Permit Type: Building 5125/07 Framinn/insualtion CN •* List of corrections not completed as of 5/25/07 : - Install drip cap window flashing on all windows - Roofing inspection faliled for numerous reasons (shingling shall done per manufacturers specifications) - Verify that the step flashing has been installed per code - Install ridge vent per manufacturers specifications - Terminate new the facia boazd correctly where it imeets the existing house - Complete porch siding @ west elevation - Double 2"x 6" roof rafrers where minimum span requirements are not met (framing above and onto the opposing roof line) and add hangers or tail blocking where required - Ventillation shoots have been instalted and inspected - Complete interior insulation and vapor barrier @ vaulted ceiling and concealed attic space azea. Make sure all framing corrections have been completed and inspected prior to sealing these areas - Floor insulation (R-38 per energy calculations submitted) has been covered prior to inspection. Verify that adequate insulation has been installed (see suggested insulation installion per Jeff Wheeler dated 12/27/05), or submit an altemate method for approval - A seperate permit wil] be required for siding the existing structure - inspections shall follow , ReportName: C11y Of.Edgilri Printed: 05/30/2007 Inspection Remazks P?e? i Inspection Remarks Permif: EA069209 Permit Type: Building 5/25/07 Deck final CN: - Remove all untreated framing members from deck frazning (added to extend decking materials) - Straighten and level beam.Center post seams to be at feast 3" to 4" out beyond the comer posu. Center post is lower than comer posts - Install ACQ (galvinized) razed nails @ joist hangers - Use galvinized framin-, nails - Install ACQ mted ledger flashing - Install rim @ end of joists - Secure deck loose deck raiting . . ry?? 2005 RESIDENTIAL BUILDING PERNIIT APPLICATION rCity Of Eagan V 3830 Pilot Knob Road, Eagan MN 55122 Telep6one # 651-675-5675 FAX # 651-675-5694 New ConstrucNon Reaui2ments RemodeliReoair Reauiremenls 3 registe2d sfte surveys shovring sq. fl. of IoL sq. ft of house; and all roofed areas 2 copies of plan (20 % maximum lot coverege allowed) 7 sel o( Energy Calculatiore for heated add'Nons 2 copies of plan showirg beam 8 window s¢es; poured found design, etc. 1 site survey for add'Aions & decks isetofEnergyCalculations Addttion - indicate'rfon-sHesepticsystem 3 copies of Tree Preservatbn Plan rf lot platted after 711193 Rim Joisl DefaJ Oplions selection sheet (bu0dings with 3 or less unAS) CL,eck + CaSC, 47 Co.AA-?cx ? 1 ??- `-`^??'V ? OHice Use Onlv CehofSurveyRecd _Y _N Tree Pres Plan Recd _ Y_ N. T2e Pres Required _ Y_ N Onsite Septic Syslem _ Y. _ N Date L5_ / 3 / ? D -" n Cost Constructi o Site Address `7 d V ? / )1/?i- T)/1/ ? /} /1/e UniUSte tl LT6 M ? 1314 ?on TC h Description of W ork ?/ . Multi-Family Bldg _ YZN Fireplace(s) 2 PropertyOwner , '1 ?,?EL P (?- 1,0 jo 0?/? _ Telephone#(pS7) ?U- ( o Contractor Address CitY State Zip Telephone # ( ) COMPLETE THIS AREA ONLY IF CONSTRUCTING A NEW BUILDING - Minnesota Rules 7670 Cateeorv 1 _ Minnesota Rules 7672 Energy Code Category . Residential Ventilation Category 1 Worksheet • New Energy Code Worksheel (4 submissiontype) Su6mitted Submitted • Energy Envelope Calculations Submitled Have you previously constructed d;bi fee applies. A- Mechanical Licensed Plumber Contractor/ Sewer/Water Contrac-tor - in Eagan with a similar plan2 _ Y _ N If so, 25% plan review Telephone #( Telephone # ( Telephone #( I hereby apply for a Residential Building Permit and acknowledge that the information is complete and accurate; that the work will be in conformance with the ordinances and codes of the City of Eagan and the State of MN Statutes; I understand this is not a permit, but only an application for a permit, and work is not to start without a permit; that the work will be in accordance with the approved plan in the case of work which requires a review and approval of plans. /11/Zf` Et l' 61?8(71)13 Applicant's Printed Name 22Zid4 t Applicant's Signature ` OFFICE USE ONLY Sub Types 0 07 Foundation ? 07 05-plex ? 13 16-plex ? 20 Pool ? 02 SF Dwelling ? 08 06-plex ? 16 Fireplace ? 21 Porch (3-sea.) ? 03 01 of _ plex ? 09 07-plex ? 17 Garage x 22 Porch/Addn. (4-sea.) ? 04 02-plex ? 10 OS-plex ? 18 Deck ? 23 Porch (screen/gazebo) ? 05 03-plex ? 11 10-plex ? 19 Lower Level ? 24 Storm Damage O 06 04-plex ? 12 12-plex Plbg_Y or_ N ? 25 Miscellaneous Work Types ? 31 New 1? 32 Addition ? 33 Alteration ? 34 Replacement Valuation ?i, Census Code SAC Units ? # of Units - # of Bldgs Type of Const _ Footings (new bldg) Footings (deck) ? Footings (addition) _ Foundation Drain Tile ? Roof 4 Ice & Water je Final Framing ? Fireplace Y R.I. I Air Test fFinal Insulation / Approved By: Base Fee V ? Surcharge Plan Review MClES SAC City SAC Utility Connection Charge S&W Permit & Surcharge Treatment Plant License Search Copies Other Total ? 30 Accessory & ? 31 Ext. Alt - Multi ' ? 33 Ext. Alt - SF ? 36 Multi Misc. ? 35 Int Improvement ? 38 Demolish Interior ? 44 Siding ? 36 Move Building O 42 Demolish Foundation ? 45 Fire Repair ? 37 Demolish Building' ? 43 Reroof ? 46 Windows/Doors 'Demolitfon (Entire Bidg) - Give PCA handout to applicant Occupancy R-3 Zoning /?%? Stories Sq. Ft. Length ? Width MCES System City Water r Booster Pump '- PRV ? Fire Sprinklered J REQUIRED INSPECTIONS Final/C.O. ? Final/No C.O. Plumbing ? HVAC Other _ Pool Ftgs AidGas Tests Final _ Siding _ Stucco _ Stone _ Brick _ Windows _ Retaining Wall Building Inspector AnI?&S?r??? ?/? .h?? . ? Permit Number RFScheck Compliance Certiflcate cneckea syiDacc 2000 IECC REScheck Software Vetsion 3.6 Release 2 Data 5lename: C:\Documcnts and Se[tings\Mike\My Documen[s\Mikes Hockey School\2005 Addition D.rck PROJECT TITLE: Gibbons Addition CITY: Eagan STATE: Minnesota HDD: 7981 CONSTRUCTION TYPE: Single Funily W INDOW / W ALL RAT IO: 0.19 DATE: 07/ 18/05 DATE OF PLANS: 5J5/2005 COMPLLINCE: Passes Maximum UA = 672 Your Home UA = 672 0.0% Bet[er Than Code (UA) Gross (ilazing Area or Cavity Cont. or poor Peiimeter -Re -1?Vaue j-Factp? 3I6 4 Season - Ceiling Main: Cathedral Ceiling (no attic) 300 38.0 0.0 8 4 Season - West Wall: Wood Ftacne, 16" o.c. 160 19.0 3.0 7 Window-Short 1 pane 3' x 2' A: Wood Frame:Single Pane 6 0•320 2 Window-Short 1 pane 3' x 2' 6 B: Wood Frame:Single Pane 7 0320 2 Window-Tall I pane 3' x 5': Wood Frame:Single Pane 15 0320 5 4 Season - East W all: W oud Frame, 16" o.c. 140 19.0 0.0 5 Window-Tall 2 pane 6' x 5': Wood Framc:Double Pane with Low-E 30 0320 10 Window-Short 2 pane 6' x 2': Wood Frame:Double Pane with Low-E 12 0.320 4 Door l: Glass IS 0.280 4 4 Season - South Wall: Wood Frame, 16" o.c. 250 19.0 0.0 7 Window-Tall 3 pane 9' x 5' A: W ood Frame:Triple Pane with Low-E 45 0.320 14 Window-Short 3 pane 9' x 2' A: Wood Frame:Tnple Panc with Low-E 18 0320 6 Window-Tall 3 pane 9' x 5' B: Wood Frame:Triple Pane wi[h Low-E 45 0.320 14 Window-Short 3 pane'9' x 2' B: W ood Frune:Triple Pane with Low-E 20 0.320 6 4 Season - South upperwall: Wood Frame, 16" o.c. 60 19A 0.0 4 ........ _......"'e" "'....,..._ .," _""_"a? ' "' _ Skylight - Kitchen 1: W ood Frame:Double Pane 10 0320 3 Skylight - Kitchen 2: W ood Rrame:Dou61e Pmme 10 0320 3 Skylight - Bath 2: Wood Frarne:Double Pane 6 0320 2 Main-Upstairs-NorthWall:WoodFrame,l6"o.c. 376 19.0 0.0 18 W indow - Bedroom 2- Kelly: Wood Frame:Double Pane with Low-E 16 0.520 8 W indow - Bedroom 3- Shannon: Wood Frame:Double Pane with Low-E 16 0.520 8 Doors - 2 entry: Solid 40 0.180 7 Main - Upstairs - Sorth Wall: Wood Frame, 16" o.c. 200 19.0 OA 11 W indow - Master Bedroam: Wood Frame:Double Pane with Low-E 19 0.520 10 Window - Master Bath: Wood Frame:Single Pane 5 0.520 3 Main - Upstairs - East Wall: Wood Frame, 16" o.c. 208 19.0 0.0 12 Window - Master Bedroom: W ood Frame:Single Pane 8 0.520 4 Main - Upstairs - West Wall: Wood Frune, 16" o.a 145 19.0 0.0 8 Window - Kithen: Wood Frarne:Double Pane with Low-E 6 0.520 3 Main - Box-Out North Wall: Wood Frnme, 16" o.c. 50 19.0 0.0 2 Window 19: WoodFrune:SinglePane 11 0.520 6 Window20: WoodFrmne:SinglePane 3 0.520 2 Main - Box-Out South Wa1L Wood Frune, 16" o.c. 50 19.0 0.0 2 Window 19 copy 1: Wood Ftame:Single Pane 11 0.520 6 Window20 capy 1: WoodFrame:SinglePane 3 0.520 2 Main - Box-Out West Wall: Wood Frune, 16" o.c. 75 19.0 0.0 1 Window 23: Wood Frame:Double Pane 18 0.520 9 Window 24: Wood Frarne:Double Pane 18 0.520 9 Window 25: Wood Frame:SinglePane 9 0.520 5 Wlndow 26: Wood Frame:Single Pane 9 0.520 5 Main - Box-Out - Floor. All-Wood JoisUTmss:Over Unconditioned Space 20 38.0 OA 1 Main - Bsmt - N. W all 4ffx47: Masonry Block with Integral Insulation 188 13.0 0.0 19 Wall height: 4.0' Depth below grade: 3.0' Insulation depth: 2.0' Window 27: Wood Frame:Double Pane with Low-E 14 0.520 7 W indow 28: W ood Frarne:Double Pane with Low-E 14 0.520 7 Main - Bsmt - N. Wall 51x47: Wood Frame, 16" o.c. 235 19.0 0.0 13 W indow - Family Room - East Wood Frame:Double Pane with Low-E 11 0.520 6 Window - Family Room - West: Wood Frarne:Double Pane with Low-E 11 0.520 6 Main - Bsmt - S. Wall 4$x47: Masonry Block with Integral Insulazion 188 13.0 0.0 78 Wall height: 4.0' Depth below grade: 0.0' Insulation depth: 0.0' Main - Bsmt - S. Wall 5dx47: Wood Frame, 16" o.c. 235 19.0 0.0 11 Window 29: Wood Frame:Single Pane 16 0.520 8 Window 30: Wood Frarne:Double Pane with Low-E 6 0.520 3 4 Season -Nodh comer wall: Wood Frame, 16" o.c. ion0n 19.0 0.0 nn '5 10 W indow 31: W ood Frune:Double Pane with Low-E Door - Sliding Glass: Glass Main - Bsmt - E. W all 4fx26: Masonry Block with Integral Insulation Wall height: 4.0' Depth below grade: 4.0' Insulation depth: 3.0' Main - Ssmt - E. Wall 5flx26; Wood Frame, 16" o.c. Main - Bsmt - W. Wal148x26: Masonry Block with Integral Insulation W all height: 4.0' Depth below grade: 3.0' Insulation depth: 4.0' Main - Bsmt - W. Wall Sftx26: Wood Frame, 16" o.c. Window - Luandry Room: Wood Frame:Double Pane with Low-E Main - Basement-Concaete Floor. Slab-0n-Grade:Unhrated Insulation depth: 4.0' Futnace 1: Forced Hot Air, 90 AFUE Air CondiTioner 1: Electric Central Air, 14 SEER 16 0.520 8 20 0.580 12 104 13.0 0.0 g 130 19.0 0.0 8 104 13.0 0.0 7 130 19.0 0.0 7 6 0.520 3 Zgg 12.0 193 COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, speci8cations, and other plculations submitted with the permit xpplication. The pmposed building has been designed to meet the 2000 IECC requirements in REScheck Version 3.6 Release 2(&)rmerly MECcheck) and to comply wifh the mandatory requirements listed in the REScheck Inspection Checklist. -=? BuildedDesigner "Date ? ? ??? ? \ , NL) . SURVEY1NG SERVtCES 4655 NICOIS ROAO EAGAM1i, MINNESOTA 55122 S1TE PLAN FOR: scNS coNSrRuCrroH co., INC. a L "' CoyrNGrotv ?AN? _ 14 I cc ?; r STl2r:? _.... _ 3._' t? ?v ?•?L o 0 ?I??Lf? ; •'ii...',c:'.,,Y,rl,; -5 /l roo.z3 ? 0 0 N o I I N I 16 ' . L---- ?IOD-09 '"- ?S B7 zs'oz"w . 96.Sa . ' ...?.JL . ' Scale : 1"- 30" - -- ----- --------------- ------- ---- - PROPERTY dESCRlPTiON LOT-a, BLOCK 3 , :? ERKSNi.RE 1?o?vas ? . acco`jrdinq to the racorded pfat thereof nAUn-rA - CouMv. Minnesota 0 0ouse- zi•-7° ioavi ? I ?W ? ? W ? ? l C. -t q V / j,J 0 V [ / ? r,-, t -6 yz() ? 2005 RESIDENTIAL BUII.DING PERMtT APPLICATION City Of Eagan 3830 Pilot Knob Road, Eagan MN 55122 Telephone 4 651-675-5675 FAX # 651-675-5694 7o.sd ms? 11 . dl%i ? New Construction Reauirements RemodelA2eoair Reauirements ORCe Use OnN 3 regislered sHe surveys showiiq sq. ft. o( l04 sq. ft. oi hause; and a11 roofed areas 2 copies of plan CeK of Sprvey Recd _ Y_ N (20%maximumbtcoveregeallowed) lsetofEnergyCelculations forheatedadddans Tree:PresPlanRerd _Y _N. 2 copies of plan showing beam & window sizes; poured found design, etc. 1 site survey for add'Nons & decks Tiee Pres Requlred Y N 1 set of Energy Calculations Addition - indicafe 'rfon-sne sepfic sysfem On-si[e Septk Sgstem _ Y_ N. 3 copies of Tree Preservatbn Plan if lat platted aRer 711193 Rim Joist DetaO Options selection sheet (bm7dings wifh 3 or fess unfts) > / I Date Site Address ? q 05 )?: ? Z (J l/( /?- 6- Construction Cost *?, s U? rd Unit/Ste # Description of Work ox t L b ?C W y? L T` W' 0?'?`?S pariAn Mu1N-Family Bldg _ YN Fireplace(s) 7L 0` 1 _ 2 Property Owner jM_L 64?i/ 6 L r- 6 Telephone #(65() Contractor Address State Zip City Telephone !t ( ) COMPLETE THIS AREA ONLY IF Energy Code Category - Minnesota Rules 7670 Cateeorv 1 _ • Residential Ventilalion Calegory 1 Worksheel (Jsubmissiontype) Submitted • Energy Envelope Calculations Submitted Have you previously constructed a building in Eagan with a similar plan2 _ Y fee applies. Licensed Plumber Mechanical Contractor Sewer/Water Contractor Telephone #( Telephone #( Telephone #( N If so, 25% plan review I hereby apply for a Residential Building Permit and acknowledge that the information is complete and accurate; that the work will be in conformance with the ordinances and codes of the City of Eagan and the State of MN Statutes; I understand this is not a permit, but only an application for a permit, and work is not to start without a `•permit; that the work will be in accordance with the approved plan in the case of work which requires a review and approval of plans. . „ I __„_ 141 lc{??? ?r G I?D3 0?5 ?. Applicant's Printed Name ApplicanYs ? A NEW BUILDING Minnesota Rules 7672 • New Energy Code Worksheet Su6mitted 5 2005 OFFICE USE ONLY Sub Types ? 01 Foundation ? 07 05-plex O 13 16-plex ? 20 Pool ? 02 SF Dwelling O 08 06-piex ? 18 Fireplace ? 27 Porch (3-sea.) ? 03 01 of_ plex ? 09 07-plex ? 17 Garage ? 22 Porch/Addn. (4-sea.) ? 04 02-plex ? 10 OS-plex X 18 Deck O 23 Porch (screen/gazebo) ? 05 03-plex ? 11 10-plex ? 19 Lower Level ? 24 Storm Damage ? OB 04-plex ? 12 12-plex Plbg_Y or _ N ? 25 Miscellaneous Work Types ? 31 New X, 32 Addition ? 33 Alteration ? 34 Replacement Valuation Census Code V/ ? ?/ ?T SAC Units # of Units # of Bldgs Type of Const V d? Footings (new bldg) ?C Footings (deck) _ Footings (addition) Foundation Drain Tile Roof Ice & Water Final _ Framing _ Fireplace _ R.I. _ Air Test _ Final Insulation Width REQUIRED INSPECTIONS _ FinaVC.O. ? FinaUNo C.O. _ Plumbing HVAC Other _ Pool _ Ftgs _ Air/Gas Tests Final _ Siding _ Smcco _ Stone _ Brick _ Windows _ Retaining Wall Approved By: I Li , Building Inspector Base Fee Surcharge Plan Review MC/ES SAC City SAC Utility Connection Charge S&W Permit & Surcharge Treatment Plant License Search Copies Other Total ? 30 Accessory Bldg ? 31 Ext. Alt - Multi ? 33 Ext. Alt - SF ? 36 Multi Misc. ? 35 Int Improvement ? 38 Demolish Interior ? 44 Siding ? 36 Move Building ? 42 Demolish Foundation ? 45 Fire Repair ? 37 Demolish Building• ? 43 Reroof ? 46 WindowslDoors "Demolition (Entire Bidg) - Glve PCA handout to applicant Occupancy MCES System Zoning City Water Stories Booster Pump Sq. Ft. PRV Length Fire Sprinklered 2l c7 c? i7 'V I 7Q - _ , S 0- ? r "RC=LAND C-0, - , - -?,6 SURVEYING _ SITE PLAN FOR: SERVICES ?$ SOtdS CONSTRUCTlON CO., INC. 4655 NICOLS ROAD EAGAN, MINNESOTA 55122 O ? COV(IVG7-ON LAN?_ l?Y ° ? ? ...... _ ?:? ....,., L .1 , Sca !e : 1"= 30" 40 ERTY DESCRIPTION ? 'LOTj?,-, BLOCK 3 , . - BERxst-+tsx.E Potvos . ... . dccordinq to the recorded plat thereoi Dauri-ra - Courrtv. Minnesota , ? ?'4o?- 2005 RESIDENTIAL BUILDING PERMIT APPLICATION City Of Eagan 3830 Pilot Kuob Road, Eagan MN 55122 Telephone # 651-675-5675 FAX # 651-675-5694 New Constmction Reauiremenls RemodeVReoair Reauirements Offce Use-0niv 3 registered site surveys showing sq. ft. of IoL sq. tt. of house; and all mofed areas 2 copies of plan Ced of Survey Recd _ Y _ N (20qo mazimum btcoverage allowed) 1 set of Energy Calalations for heated additions Tree Pres Plan Recd _Y _ N, 2 copies 6f plan shawing beam & window s¢es; poured found design, etc. 1 sRe survey for additlons 8 decks Tree Pres Required _Y _ N 7 set of Energy Calculations Addifiwr -indicate i/onsite septicsystem On-sile 5eptic System _Y _N 3 cropies of Tree Preservation Plan iilot platted after 711/93 Rim Joist Deisil Options selection sheet (buildings wAh 3 or less units) Date 0r ? Construction Cost SiteAddress lC12 10 et7V( ??7'?? ?'', Unit/Ste # Description of Work ?/?'? S// ?I.L c, ?jl?/ f s 'LI?X, 1? Mutti-Family Bldg _ YtN Firepiace(s) _ 0 {'l 1 _ 2 ?{^ Property Owner I"1 i / t M 1 l? N? ( ?i MC.)A-)5 Telephone # ((99 ) ya - fd5 ? Contractor ? Address vJ. (3 City a??l ?l:L State Zip Telephone #(?'Z) COMPLETE THIS AREA ONLY IF CONSTRUCTING A Energy Code Category Minnesota Rules 7670 Catecorv 1 _ • Residential Ventilation Cafegory 7 Worksheet (Jsubmissiontype) Submitted • Energy Envelope Calculations Submitted -# -,n. c-0 BUILDING Have you previously constructed a building in Eagan with a similar plan? _ Y fee applies. Licensed Plumber Telephone #( Mechanical Contractor Sewer/Water Coniractor Telephone #( Telephone #( I hereby apply far a Residential Building Permit and acknowledge that the information is complete and accurate; that the work will be in conformance with the ordinances and codes of the City of Eagan and the State of MN Statutes; I understand this is not a permit, but only an application for a permit and work is not to start without a permit; that the work will be in accordance with the appro plan i case A/'vork,which requires a review and approval of plans. ? ?C ??T Applicant's Printed Name Appl? ant's Signature ? ? 2005 RESIDENTIAL MEQH.?INICAL PERNIIT APPLICATION V City Of Eagan 3830 Pilot Knob Road, Eagan MN 55122 Telephone # 651-675-5675 Please complete for: single faznily dwellings & townhomes/condos when petmits are requued for each unit Date W- / 9- / QS Site Address ? Unit # hane # ( (?l / ) 7?? ?? '?7 ? Tele P t O p raper y wner Contractor ' ,,,,, ' Street Address $910 Went:vorth Av?j : u City State (952) 881-9000Zip Telephone # ( ) Bond #: Expires: The Appticant is _ Owner _Z Contractor _ Other Add-on or alteration to existing dwelling unit ne_,V _// C/? ?ct ?! 6 ! 3?.00 ? fumace _Additional 1/Replacement _ New air exchanger i i _zZ a r condit oner heat pump other State Surcharge $ 50 Total $ ? ah. ? , I hereby apply for a Residential Muhanical Permi[ and aclrnowledge that the information is complete and accurate; that the work will be in conformance with the ordinances and codes of the City of Eagan and with the Mechanical Codes; that I understand this is not a pemut, but only an applica6on for a pernut, and work is not to stazt without a pemtit; that the work will b in accordance with the approved plan in the case of wor hich requires a review and approval of plans. ApphW**6"UT Applicant's Signature 8910 WentwortR qve??oQN'NGLLC; Minneapolis, MN 55420 . ? (952) 881-9000 TRI-LAND C0. SURVEYING SERVICES 4655 NICOLS ROAD EAGAN, MINNESOTA 55122 SITE PLAN FOR: SONS CONSTRUCTION CO., INC. 0 _ ? COV(NGTON L?{? ` loo.oo Na6•z6'tie`w 9G?Y ioo.oo O ? ------------- 1 ? ?•Y9 ino.oz ? ? N e ?adre ? ? g ,? I" ? I .. .... _ a... I 100.43 •?7•• I04.Y7 I N ; 1;?. fOG.S? ry o I "? ? o I `? House N I o ? o a -40. I iaa r ?? roo.x; ? 51 o P ? I 0 I I z° „ 1 16 i - 1 i L--'_'---'---'` g 10 o.Q9 f? S 8T°t?'oi w oe q6.So . . ?: . ,.. ,. ?, i..'..! L ... : . Scale : 1'"° 30' PROPERTY DESCRIPTION LOTp 1(0, BLOCK.?, pERKSH?RE Aotins aceordinQ to the recorded plat thereoi ?AkCTO CouMy, Minnesoto LEGEND o DENOTES IRON MONUMENT ? DENOTES WOOD HUB SET DENOTES EXISTING SPOT ELE VATI ON DENOTES PROPOSED SPOT ELEVATION DENOTES DRAINAGE DIRECTION 1 hereby certify fhat this survey,plun or report was prepared by me or under my diract supervision and that I am a duly Reqistared Land Surveyor under the Laws of ihe Stute of Minnesota. 50 W Z W ? ? W Q J V 50 PROPOSED GARAGE FLOOR ELEVATION= (ol.so PROPOSED FIRST FLOOR ELEVATION = 1oi.oo PROPOSED BASEMENT FLOOR = E LE VATI ON NOTE: VERIFY ALL FLOOR HEIGHTS WITH FINAL HOUSE PLANS 1,1Y Bradley J. enaon, Mn. Req. No. 15235 Date ? /0h9/BS t TRI-LAND C0. SURVEYING SERVICES 4655 NICOLS ROAD EAGAN, MINNESOTA 55122 0 M ? o 1OOAU ..... ? ? ?, 0 0 0 > t aP 0 .a .o N SITE PLAN FOR: SONS CONSTRUCTION CO., INC. C0v1NG1- aN LAN- E---,?-_ i? I N8@'26'Y8"W 9Oy ; ? 0 a 0 ? .50 •SO Scale : 1"= 30" PROPERTY DESCRIPTION LOTp 1?2, BLOCK5 , CJERKSNIRE PocvoS aecordinq to the recorded plat Thereot Da,urJ-ra CouMy, Minnesoto LE6END o DENOTES IRON MONUMENT o DENOTES WOOD HUB SET DENOTES EXISTING SPOT ELEVATION DENOTES PROPOSED SPOT ELEVATION ? DENOTES DRAINAGE DIRECTION I hereby certify fhat this survey,plan or report was prepored by me or undar my direct supervision and that I am a duly Reqistered Land Surveyor under ihe Laws of the State of Minnesota. Brndley J. enson, Mn. Req. No. 15235 Dote: /0/2e/es- W D Z w > Q W Q J Q ? So PROPOSED GARAGE FLOOR ELEVATION= lol.so PROPOSED FIRST FLOOR ELEVATION = ?02.00 PROPOSED BASEMENT FLOOR = E LE VATI ON NOTE * VERIFY ALL FLOOR HEIGHTS WITH FINAL HOUSE PLANS rozm ser-z"z w ?{1 ....a???L ..1. :?• PERMIT City of Eagan Permit Type:Building Permit Number:EA119818 Date Issued:12/19/2013 Permit Category:ePermit Site Address: 1926 Covington Lane Lot:16 Block: 3 Addition: Berkshire Ponds PID:10-13750-03-160 Use: Description: Sub Type:Windows/Doors Work Type:Replace Description:Two or More Windows/Doors Census Code:434 - Zoning: Square Feet:0 Occupancy: Construction Type: Comments:Improvements to the home require smoke detectors in all bedrooms. If altering window openings, call for framing inspection. Call for final inspection after installation. Carbon monoxide detectors are required by law in ALL single family homes . Valuation: 4,000.00 Fee Summary:BL - Base Fee $4K $103.25 0801.4085 Surcharge - Based on Valuation $4K $2.00 9001.2195 $105.25 Total: I hereby acknowledge that I have read this application and state that the information is correct and agree to comply with all applicable State of Minnesota Statutes and City of Eagan Ordinances. Contractor:Owner:- Applicant - Michael & Nancy Gibbons 1926 Covington Lane Eagan MN 55122 (612) 229-3449 Mn Superior Exteriors 1048 B Payne Ave N St Paul MN 55130 (651) 774-5582 Applicant/Permitee: Signature Issued By: Signature 40/11. City of Etall 3830 Pilot Knob Road Eagan MN 55122 Phone: (651) 675-5675 Fax: (651) 675-5694 Use BLUE or BLACK In For Office Use Permit #: Permit Fee: / J" ;,?5 Date Received: Staff: 2016 RESIDENTIAL BUILDING PERMIT APPLICATION Date: t O q/K0 Site Address: l q C.ovrL , L..fes°` Unit #: Resident! Owner Name: Jcc (Gt-t' 4/10t/of Phone: c/2.27it. 3Liget Address / City / Zip: I C 2.4 C Otiori5 j - c,..-1 L.4.', PaS,,„� ,4.i 5-5-1 2 L Applicant is: Owner V Contractor Type of Work Description of work: Re - Rcc' +- Construction Cost: I -1-0-"S I -4-g! Multi -Family Building: (Yes / No /� ) Contractor Company: Z I'( tae iro i -R- Contact: Sec i at/. Li& 9, 7 co -_ Address: CPC,/ C-1 `((s' -/QVC- %,•tet/ City: Pc{vPIScY State: /f/I,4/Zip: 5 c30 Phone: 743, 753, email: 5 71-f eeSame-c.Cc.A.4-. License #: 13 C 3013 7-1 Lead Certificate #: If the project is exempt from lead certification, please explain why: In the last 12 months, Yes No COMPLETE THIS AREA ONLY IF CONSTRUCTING A NEW BUILDING has the City of Eagan issued a permit for a similar plan based on a master plan? If yes, date and address of master plan: Licensed Plumber: Mechanical Contractor: Sewer & Water Contractor: Fire Suppression Contractor: Phone: Phone: Phone: Phone: NOTE: Plans and the information supporting documents that you submit are considered to be public information. Portions of may be classified as non-public if you provide specific reasons that would permit the City to conclude that the are trade secrets. CALL BEFORE YOU DIG. Call Gopher State One Call at (651) 454-0002 for protection against underground utility damage. Call 48 hours before you intend to dig to receive locates of underground utilities. www.gopherstateonecall.org I hereby acknowledge that this information is complete and accurate; that the work will be in conformance with the ordinances and codes of the City of Eagan; that I understand this is not a permit, but only an application for a permit, and work is not to start without a permit; that the work will be in accordance with the approved plan in the case of work which requires a review and approval of plans. Exterior work authorized by a building permit issued in accordance with the Minnesota State Building Code must be completed within 180 days of permit issuance. x Applicant's Printed Name s Signature Page 1 of 3 PERMIT City of Eagan Permit Type:Plumbing Permit Number:EA167621 Date Issued:03/23/2021 Permit Category:ePermit Site Address: 1926 Covington Lane Lot:16 Block: 3 Addition: Berkshire Ponds PID:10-13750-03-160 Use: Description: Sub Type:Residential Work Type:Replace Description:Standard Water Heater Meter Size Meter Type Manufacturer Serial Number Remote Number Line Size Comments:Carbon monoxide detectors are required within 10 feet of all sleeping room openings in residential homes (Minnesota State Building Code). Please call Building Inspections at (651) 675-5675 to schedule a final inspection. Fee Summary:PL - Permit Fee (WS &/or WH)$59.00 0801.4087 Surcharge-Fixed $1.00 9001.2195 $60.00 Total: I hereby acknowledge that I have read this application and state that the information is correct and agree to comply with all applicable State of Minnesota Statutes and City of Eagan Ordinances. Contractor:Owner:- Applicant - Vayong & Pha Chia Moua 1926 Covington Ln Eagan MN 55123 Champion Plumbing 3670 Dodd Rd., #100 Eagan MN 55123 (651) 365-1340 Applicant/Permitee: Signature Issued By: Signature PERMIT City of Eagan Permit Type:Building Permit Number:EA170010 Date Issued:06/17/2021 Permit Category:ePermit Site Address: 1926 Covington Lane Lot:16 Block: 3 Addition: Berkshire Ponds PID:10-13750-03-160 Use: Description: Sub Type:Siding Work Type:Replace Description: Census Code:434 - Residential Additions, Alterations Zoning: Square Feet:0 Occupancy: Construction Type: Comments:Please leave printed pictures of house wrap on site for the final inspection. When installing ventilated soffit material, remove existing material (i.e. debris that could block vents) and take steps to ensure maximum ventilation to attic. Call for final inspection after installation. When a weather barrier is installed or Valuation: 5,000.00 Fee Summary:BL - Base Fee $5K $118.00 0801.4085 Surcharge - Based on Valuation $5K $2.50 9001.2195 $120.50 Total: I hereby acknowledge that I have read this application and state that the information is correct and agree to comply with all applicable State of Minnesota Statutes and City of Eagan Ordinances. Contractor:Owner:- Applicant - Vayong & Pha Chia Moua 1926 Covington Ln Eagan MN 55123 (612) 229-3449 Jr Remodelers & Builders 2920 Greenbrier St St. Paul MN 55117 (612) 770-4261 Applicant/Permitee: Signature Issued By: Signature