Loading...
1458 Englert RdAddress: 1458 Englert Rd Lot: 5 Block:l Subdivision: Waters Edge Zip: 55122 THE FOLLOWING ITEMS WERE/WERE NOT COMPLETE AT FINAL INSPECTION ON ?- -) 3,-O Yes No Comments Final grade - 6" from siding ; s Permanent ste s- gara e $C Permanent ste s- main entry Permanent driveway X Permanent as X Retainin Wall or 3:1 Maac 51o e X Sod/Seeded lawn Trail/curb dama e Porch Lower level finish Deck X Fire lace X • Verify with your buildcr that roof test caps from the plumbing system have been removed. • Turn off water supply to the outside lawn faucets before freeze potenlial exists. • Call the City's Engineering Depar[ment at 651-675-5646 prior to workmg in rightof-way or installing irrigation system. J BUILDINC INSPECI'OR: 3 CONTRACTOR: McDonald Construction 7601 145th Street W Apple Valley MN 55124 IT= = CO INSTANT TESTING COIMPANY 7125 West 126"' Street Suite 500 Savage, hNIN 55378 •(952) 890-7366• Fax: (952) 890-5883 DENSITY TIiiST REPORT KEN CORDES SPECIALIZED Tl1RF 12255 120T" STREET SOUTH HASTINGS MN 55033 Proieet: 1458 Ennert Road. Eanan bate 7ested: August 19, 2004 @ 1120 am prdered By: Ken Cordes Repr_ ited! August 20, 2004 Fielcl'fechnician: Davfd Kolstad, 17C0 Inplace DensHy Tes= Test Humber. 1511111111111111 LocaGon: 1 SW comer of buildin De th Below Grade: Grede Visual Soil Class: Loam sand Proctor Curve Number: 0401 Percent Moisture: 4.3 O timum Mbisture: 9.7 Relative Molsture. Percent: 116 Field Densl , PCF: 126.6 Standard Maximum D Densi , PCF: 128.8 Relative Densi , PerceM: 98 Re uired Minimum: 95 Remarks: Copies To: Charge Codes: Pads constructed of en8ineered fill could be subject to a io .: nf consolidatlon if loft unhuiR upon over a smgle wlnter. Penetrating frost comGineC wifh a season of F?eze•thaw cycles might loosen soils to the depth of the frost. This applles to fill composed ot gither gr,enular or fine-grained coheslve material. All pads left exposed for one winter should be inspeCted by a g-:ocechnical engineer or technician. Mobilization #701 1 Density Tests 1 #601 i Charge Per Test t1306 1 Mileage #812 22 . J ? ?! Signed _ ? Dan.iil J. Naughton, P essional Engince Registratlon No. 20191 T00121 QllI'I'Id/901592 S.Nd.LSNI C889068 Rt3 Cfi:bT OZ/80 EOOZ 6 0 Siteaddress: IqSY ClJ6LG2.T C?? Lot S Block --L suna. YJATtJP-s Eb&E On April 15, 2000 the Minnesota Energy Code, Category I Building Requirements for insulation protection, air tightness, and ventilation, was adopted. As a result, the City of Eagan is requiring that the following information be su6mitted prior to issuance of a Certificate of Occupancy. ? This structure: is consWCted to meet minimum requirements of the Mn Energy Code, Chapter 7670 OR _ This structure: will be constructed to meet more restrictive requiremenGs of Chapters 7672 or 7674 APPLL4NCE GAS ELEC MANUFACTURER MODEL 8TU'S VENTINGTYPE WaterHeater 1/ (j,-Qd&r4 WHt7G ('1ZsyrW50 Tb Bd 4Sooo powfrVrn"E Furnace V11' V,,,ZX}M?"9- 69M PD I opJZo oo 000 J\VGCf V?e - Dryer tl/ y,JNrLLPoob 66 w laoo L -a I 006 T\Ye(?7 v2n} EXHAUST SYSTEM LOCATION TYPE MODEL CFM's VENTED YES No Kitchen kitchen Venk-a-k-4ovc{ SLN?18'13?0 3a? ? Bathroom 1 MA tQ, ljvUPFN S0 Lc. Bathroom 2 p ?? ?r?Q? S g 0 Gf VU L,- Bathroom 3 Bathroom 4 Other j%s"cR. ?oYOa" FIREPLACE S LOCATION GAS WOOD MANUFACTURER MODEL BTU'S VENTING DittECT ATI#OS yLo- 2. R n ? Ntn4 -n-6L0 &000 TR 30,000 ? MAKE-UP AIR MODEL TYPE CFM's N? fjC I hereby acknowledge that the above information is correct and agree to comply with the Minnesota Energy Code and City of Eagan requirements. 1,M)3 loy Si r@ L.D{?/?VL(° ?/DN, ?NC, Dat ?O !(Y CompanyName This form is the responsibility of the General Contractor. L& L:? 6i c?ck i S-r-?? ??? ?7 y- 6 Q 2004 RESIDENTIAL BUII.DING PERMIT APPLICATION City Of Eagan 'tYl'P 3830 Pilot Knob Road, Eagan MN 55122 ip P Telephone # 651-675-5675 FAX 4 651-675-5694 New ConsWction Reaui2menb 3 registered site surveys shwrirg sq. R of bt, sq. R of house; and all roofed areas (20% mazimum bt coverage allared) 2 copies ot plen shmmg 6eam 6 window sizes; poured found design, eic. 1 set of Energy Calculations 3 copies of Tree Presarvafron Plan if lot plat0ad aflx 717183 Rim Joist Defail Options selection sheel (bldgs wifh 3ur-less un'rts ? (05(,rj -, S?6014 .qg ri o.sb (?5.Lt9 RemodeVReoa'vReauitemants _nK SOB . 2 copies of plan ?.. ??, 1 sel of Erreigy Calwletions for heated addHlons Tfree?;?e3 _??, _, {- 1 site survey for addiUons & dedcs f„r? _??,?`^=N Add'?lon - indicate if on-sne seplic sysfem ?? ci _ 16? n Date ? 3 ?. O6 Construction Cost 104'? Site Address /? ? ? , r? ?? ?o"4) UniUSte # T Description of Work Multi-Family Bldg _ Y ,, N ` Fireplace(s) _ 0 x 1 _ 2 Property Owner MtO4 n n c,. `V l C`? ??y Telephone #(F,'?L) 4-,?aY • 7 6CD / ? 7 ? ' a Contractor c - , c?`y' C t?C e Address ?;n ?,/ i I Ltc"?. City _ ?ir -. State z!PZ;3"r2L y Telephone # 19CZO !. F. A COMPLETE THIS AREA ONLY IF CONSTRUCTIN6 A NEYY BUILDING ? Tvlinnesota Rules 7670 Cateeorv 1 _ Nlinnesola Rules 7672 Energy Code Category . Resldential Ventilation Category 1 Worksheet • New Energy Code Worksheet (q submission type) Submitted Submitted . Energy Envelope Caiculations SubmiNed Have you previously constructed a building in Eagan with a I?r ptan? ??? N If so, 25% plan review fee applies. J UL 9 2004 Licensed Plumber F v-c- tC_ ?one #( J?S?/ 3 Mechanical Contractor ?co nT?d r?rJ A f? Telephone #(Fj$"f) Sewer/Water Contractor Vz,?r-_E? ewiu???5 - Telephone #F&gT?SR'I - rlok 3? I hereby apply for a Residential Building Permit and aclmowledge that the information is complete and accurate; that the work will be in conformance with the ordinances and codes of the City of Eagan and the State of MN Statutes; I understand this is not a permit, but only an application for a permit, and work is not to start without a permit; that the work will be in accordance with the approved plan in the case of work which requires a review and approval of plans. a'Q C L" 12x?l sv-- ApplicanYs Printed Name OFFICE USE ONLY Sub Types 0 01 Foundation ? 07 05-plex ? 13 16-plex ? 20 Pool ? 30 AccessoryBldg P< 02 SF Dwelling ? OS 06-plex ? 16 Fireplace ? 21 Porch (3-sea.) ? 31 Ext. Alt - Multi , ? 03 01 of _ plex ? 09 07-plex ? 77 Garage O 22 PorchlAddn. (4-sea.) ? 33 Ext. Alt - SF ? 04 02-plex ? 10 08-plex ? 18 Deck ? 23 Porch (screen/gazebo) ? 36 Multi Misc. ? 05 03-plex ? 71 10-plex ? 19 Lower Level ? 24 Storm Damage ? OB 04-plex ? 12 12-plex Pibg_Y or_ N ? 25 Miscellaneous wark TyPes , ?? 37 New ? 35 Int Improvement ? 36 Demolish Interior ? 44 Siding ? 32 Addition ? 36 Move Building ? 42 Demolish Foundation ? 45 Fire Repair 0 33 Alteretion ? 37 Demoiish Building` ? 43 Reroof ? 46 Windows/Doors ? 34 Replacement •Demolitlon (Entlre Bldg) - Give PCA handout to appllwnt Valuation 1gpo Occupancy '?7 V ??? MCES System Census Code ?_) Zoning City Water SAC Units Stories ? Booster Pump # of Units T_ Sq. Ft. PRV # of Bldgs Length o? Fire Sprinklered Type of Const Width Footings (new bldg) REQUIRED INSPECTIONS FinaVC.O. _ Footings (deck) FinaUNo C.O. Footings (addition) Plumbing ?C Foundation _ HVAC _ Drain Tile Other ? Roof _ Ice & Water _ Final = Pool = Ftgs =Air/Gas Tes Final Framing Siding Stucco Stone ? Bric Pireplace V R.I. ,f Air Test I Final Windows ?L [nsulation ? Retaining Wall Approved By: Building Inspector Base Fee n (,,?n y Surcharge 3? y?? Plan Review MC/ES SAC City SAC , . , Utility Connection Charge S&W Permit & Surcharge ?fv'?? wr u o" ?,3 r v??p ? f/,?,?.? Treatment Plant License Search OtheeS Total ? 1 q y, ? Yerntit Number REScheck Compliance Certificate Checked By/Date 2000 Minnesota Energy Code RES check Software Version 3.5 Release 1 Data filename: C:\Documents and SettingsWaron Koller\Desktop\rescheck\04-287.rck TITLE:04-287 COLTNTY: Dakota STATE: Mirmesota ZONE: 2 CONSTRUCTION TYPE: Single Family DATE: 06/29/04 PROJECTINFORMATION: TINO & WONNEDA HING COMPANY INFORMATION: McDONALD CONST. INC COMPLIANCE: Passes Maxunum UA = 609 Your Home UA = 478 21.5% Better Than Code (UA) Gross Glazing Area or Cavity Cont. or poor Perimeter R-Value R-Value U-Fac[or UA Ceiling 1: Flat Ceiling or Scissor Truss 2566 45.0 0.0 69 Wall 1: Wood Frame, 16" o.a 3361 19.0 2.0 158 Window ]: Above-Grade:Above Grade, Wood Frame, Double Pane with L ow-E 417 0310 129 Door 1: Solid 20 0.230 5 Door 2: Solid 33 0.350 12 Door 3: Glass 78 0.330 26 Basement Wall 1: Solid Concrete or Masonry 1188 11.0 0.0 67 Wall height: 8.8' Depth below grade: 8.2' Insula[ion depth: 8.8' Basement Wa112: Solid Concrete or Masonry 172 11.0 0.0 12 Wall height: 3.5' Depth below grade: 3.0' Insulation depth_ 3.5' Floor 2: All-Wood JoisUTruss:Over Outside Au 12 38.0 0.0 0 Fumace 1: Forced Hot Air, 90 AFUE Proposed and Maximum U-Factor Averages Proposed Maximum Avetage U-Factor Allowed U-Factor Above-Grade Windows and Glass Doors 0313 0.370 Includes Foundation Windows > 5.6 fr2 COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications, and other calculanons submitted with the permit applicahon. The proposed building has been designed to meet the 2000 Minnesota Energy Code requirements in RES checkVersion 3.5 Release 1(formerly MECchec? and to comply wnth the mandatoty requirements listed in the R i checkInspection Checklist. Builder/Designer????iyr??/r?/ ?? c Date C) ? c I?? .GGJ Jc._ Jon si W Add,,'Ss. "CATEGORY 1" ALTERNATE FOR ONE & TWO FAMILY bWELLINGS *CitV oF ecigc INSTRUCTtOYS: This altcrnstive msy 6e used for one- and two-[amily dwellings Dallt to meet the Catcgury 1 requirements of Minnesota Rules, Chapter 7670. Complete Parts A. B. and C, Cleuty mark plans with: insufazion A-values, window and skyGght U- values; size and type of equipmenC equipment conVOls; and location of vapor «mrdcr and windwuA barricrs. More detaikd information can bc found in the Minnesota Ertergy Code summary sheers avylable From tAe Minnesora Depnrmient of Commerce. Part A. BUILDTNG ENVELOPE Check proposed envelope joint eealing op6on 4 O-Prc?-pdve (ceulking, gaskets. etc.) .... O Perfonnance (res[ per 7670.0470 suDp. 7.C.) Cbeekthamal mcgy ealeWation opCOO used 4 O"Cookbook" (eompleee wohshen below) ?K MnCh:ck medon (anxh rcpnn) O Perfomsnce (amep U-velur esleulatione) q Systems Mslysis medwa (a¢vch aoafyeis) "Cookbook" Worksheet INSfRUCT10N5 Step 1. Check ium(s) [hat design maa on Nlnimum Requiremons IIc[ m tbc ngh4 Musc mrn ell icems w ux -Cookbook" opiion. Siep 2. fndican proposed wall rype oo mble bebw. Sery 3. Indieam Window U•volue artd source. 5[ep 4. verify wisl window (ineluding area otill fovndauon windows) snd daor area is epuol cr less then alfowabk percmwge. Caltng Insulanon: Muumum R-38 with 7Y," eneryy becl; or Muwnum R-14 wiUi low mus hee1; Or TnHLE FOR DE7 ERM(NiN G M?1i 7M W1NDpW AND DODR aREa Mutimum Allowable Toral Windaw nnd DoorArea ss ePeccenp ofE. scdWell---? 12°h 14% 16°k 18'/0 20% 22% 24°k 26% 26% Wall T fSUnQar6 Ftsinin : Meximu m A Window ?F.value ezc e foundation windows : 02ca, R-13 insuW[ion, R•7 shcathi 0.55 0.47 O.a! 036 0.33 0.30 0.27 0.25 013 ? 2x4, R-IS insuladon. R-i sDeatAin 0.52 0.45 039 0.35 0.31 028 0 26 0.14 0.22 Q 24 R•19 insulaaon, <R-5 Shcedhin 0.08 0.4t 0.36 0.32 0.29 0.26 0.24 012 0.21 0 2c6. &-14 insulanon, R-5 sheathing 0.56 O.aB 0.a2 0.37 034 0.31 0.28 026 0.24 0 2z6. R-21 insulauon, <R-5 thrnthin 0.51 0.43 O.SB 0.34 0.30 0.28 0.25 0.23 0.22 0 2z6, A-21 instilation, R-5 3hm[hing Wa0 T Advaaeed Fiamin : 0.58 Maximwm 0.50 0.41 039 Avefo e Window U-vdlue ex 0.35 t Faunda 0.32 0.29 0.27 015 tion windnwsl: ? 2c6, R•t9'vuvlapon. ? R-5 cAeachin 0.52 0.45 0.39 035 031 0.28 0.26 0.24 0.22 0 bc6. R• 19 insulauon. R-5 sheahi 0.58 0.50 0.44 039 0.35 032 0.29 0.27 025 O 7x6. R41 insulauon. < R-5 sReaNm O,SS 0.47 0.41 0.36 0.33 a.30 0.27 0.25 0.23 O 2z6, R-21 uwulption. R-5 shesrh(ng 0.60 0.52 0.46 001 0.36 033 0.30 028 026 Window U-vslue: ? Souree; O T7FRC O ASFIRAE 1993 HytdEook 100x?.;C?-??<? window & door area goss ofpoeed wall area DESICN ALLOw'ABCE (trom table ebwe) MlNNESUTA ENERGY CODE - WNJCH RULES MAy I USE ? TVPE OF RESIDENT[qL BUILDfNG APPLICASLE RULES Dewthed R-7 oaupancy i- and 2-family dwalllnss Gwpter 7672; or Exam la: sin te (omil , nvin homes, d Icza Cha iq 7670 "Caleyory I" with statuimy tle ressuriadon and veneila4on viicmrnes Aaached R-] oeenpaacy dwdlinga Clmpttt 7674: or Ecvn kr tri lex lowMOUSes end row Aousa CAa ter 7670 wiih eithu "Cateury I" or "Category 2" rovisions R-1 occvpancy bullAings of 3 6torles or len Chnpm 7674; or Exam les: eonOOmimum.e or o aronenu Cha ter 9610 with erthcr "Care o I" a^Cote o 2^ rovison: A-1 aaupnncy bupolnef over J SNrIK hfe11 CILlpcer 7676 Esam les: h? btisteendo?ora men?s 1. ' JUL-10-2061 10:06 651 681 4694 96i P.05 c.i iV l VV'?? GnllrllY Llvil`.i. L??. ? JJ.JG'?JLIJOG ??U.VOJ Vc.? ' NEW CONSTRUCTION ONLY Part B. DEPRESSURYZATIQN PROTECTION Check uption used: O Fuel buming equipmeni (compleu schtdules beloW) D No fuel buming equipmenc lNSTRUCTI0N5 . $tcp 1. Complete the Combw•iion £qjupmenr ScFedule below. Only equipmenc with a Y(Yes) may be selected under the "Category I" altemate. Step 2. Complete Eshaur?Mnke-up Arr Schedufe on tbe nght ifdirect or power vemed nr soli0 fuel atmospheric vent space heeting equipment is selected. Exhaust COiMBUSTYON EQUIPMENT SCAEDULE check all es o osed) Spate heating - nonsolid fuel ealed cumbustion Y Heatth - nonsolid fuel O Sealed combusROn Y O Dvect or powa vented Y• O Diren ur power venied Y Am?o haicalt venmd N Amao herieall venud N Wazer hearing- oonsolid tucl O Scaled combustion Y Space heaong - solid fuel D Aanosptiaicslly venteA Y. O Director owuvented Y Wekrheatin -solidfiul O Aaw hericall venied Y Ahnos hericall veated N Hearth-solidfuel O Atrnas hericall venad Y If atmosphericelly verted solid fuel or dircct or power venkd noesolid fuel space hen[ing is instsllcd, thm mekrup air tu match tlow w is rc uired for rreh individual exhaust deviee whicii exceeda 300 cubic feet er minute. Part Ci. VENTILATION vsrrrIr.nrtox QonxrnY (Mechanical ventilalion must he provided per the larger quanriry calculaud below) ? ? euhie Feet x 0A0563/minute =? cfm (? x 15 efm/bedroom) + 15 cfm efm volume of habitsble rooinv number of 6edmoms Check method(s) proposed 4 VENTII.ATION FAN SCHEDULE ? Ezhaust oal Balanced eat recovem" ventilatar, au exchan er, ete. Fan ducri 4on or location 4 TOl'ALS VENTCT,ATION lntake cfm cfm cfm cfm cfrn AS DESIGNED Ezhaus[ cfrn cfm cfia cfm cfm Siatement of Comp6ance: 'ILe pro posad buildin design represenkd in these doeuments is consisient with the building plans, spccificadons, and other celculaiions submined with the,.permit applicarion. The proposed building tias been designed ro meet the ?J emen o e Minneso?a--Energy Code. 3? ` - ?..21?? Applfcsnt (print name) 9 t Dam Telephone number Part C2. VENTILATION (Snbmlt Part Cz upon compleriaa of system veriticationt) x - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - Iob Sim nddress: permit Number Fan deseri tion or loestion TOTALS MEqSURED Incslce cfm cfm cfm cfm cfm PERFOAMANCEt Exhaust efin efin cfm cfm efin T Ventila.tion rale must be measured snd verified when the perFormance oytian is used in lieu of the prescripuve option for tAe seelin of'oina in tAe Duildine condicioned rnvelo e(from Pan A. Camplisnee Smtmient: Insenllcd ven[iWtion system is in compliance wi[h MN Energy Code and is sized [o provide the design air flow. Signaturc Dete Telcphone numbsr Applicanl (print name) JUL-10-2001 10:07 651 681 4694 96% P.66 ? TREE PRESERVATION.,;PLAN.:?SU,MMARY. - "CITY OF EAGAN FORESfiRY DIVISION' - ` ... Ir 691 ?675-530D'? (PLEASE READ ATTACHMENTS) Development Lot Number ] Block Number ? Address 6N6-6ERT 2/ Builder n1 C7SUrUtt.i) C'ONS7? PHONE NUMBER: L,/Z CONTACT: 1 LFt' Tree Protection Reauirements: ? Tree Protection Fencing Installed On Site Oak Tree Pruning (Immediately seal wounds during April 1 to July 31) Therapeutic Pruning Retaining Wall Other: Replacement Trees: Not Required As Follows: °--? EA Attachments: Yes No _ll Additional Notes: - ?? -? ? H:\ghove\2004fi1e1treepres\Tree Preservatlon Plan Summary-2004 ' LOT SURVEY CHECKLIST FOR RESIDENTIAL ' BUILDING PERMfT APPLICATION PROPERTYLEGAL: -h6`I" S, P1Iw-? DATE OF SURVEY: LATEST REVISION: m oi c m L U Y a ? 0 Z a DOCUMENT STANDARDS ? ' ? ? • Registered Land Surveyor signature and company ? ? ? • Building Permit Applicant iz ? ? • Legal description 'Cl' ? ? • Address .d ? ? • North arrow and scale '01 ? 0 • House rype (rambler, walkout, split w/o split entry lookout etc ) "6 ? 0 . , , , . Directional drainage arrows with slope/gradient °/, 'P ? ? • Proposed/existing sewer and water services & invert eleva5on ? ? 0 • Street name ? ? ? • Driveway (grede & width - in RNJ and back of curb, 22' max.) 'PJ ? ? • Lot Sguare Footage 'P ? ? • Lot Coverage ELEVATIONS Existina Jd ? ? • Sewer service (or Proposed) '0 ? ? • Property comers ,gr ? ? • Top of curb at the driveway and property line eMensions )2 ? ? • Elevations of any existing adjacent homes )z ? ? • Adequate footing depth of structures due to adjacent utility trenches ,? ? ? • Waterways (pond, stream, etc.) Prooosed )a ? 0 • Garege floor Jd ? ? • Basement floor 11 ? ? • Lowest exposed elevation (walkoutlwindow) ? ? • Property comers ? ? ? • Front and rear of home a[ the foundation PONDING AREA (if apolicabie) /Z 0 0 • Easement line ,H ? ? • NWL ? ? D • HWL ? ? ? • Pond # designation " fd ? ? • Emergency Overflow Elevation ,B ? ? • Pond/Wetlandbufferdelineation DIMENSIONS ,0 ? ? • Lot lines/Bearings & dimensions g 0 ? • Right-of-way and s[reet width (to back of cur6) ,171 ? ? • Proposed home dimensions including any proposed decks overhangs reater than 2' orches etc , g , p , . (i.e. all structures requiring permanent footings) ,0 ? ? • Show ail easements of record a City utilities within those easements ,0 0 0 • Setbacks of proposed structur eyar Ja d setGack of adjacent exis[ing structures ? ? ? • Retalning wall requirements a Reviewed: 30 ¢ ame Date G:lFORMS/Building permit Application Rev. 72-16-03 Building Permit Survey for: McDONALD CONSTRUCTION, INC. LEGAL DESCRlPTfON Lot 5, Block 1, WATERS EDGE, according to the recorded plat thereof, Dakota County, Minnesota. 15r-ST 15" 0 8" -W- ? EN 854 `t BC -Ni-... _ -8°-S---F Sanitory sewer service = 844.0 feet (Per plan) O ? 860.9 ? ? . I ? 6 s. ? :.. y .`7 7 4?i = g5? ? s 853.8 e?"? ? 14" Cant ever '. 5cale: 1 inch = 30 feet 850.8 85 Top 853.75 lnv. 845.37 MH -S : ER T :? Garage Floor E ion = 857.45 Top of , LEW ? ?JS Basemen By 11 l p? yZ-1a/oL ?NG?ERIIVG D?T: gaaay 87.00 x - n 0 0 ? N /Qg3 °o ?ee a ?b LL?i.QQJ \ 7 1.6 851.5 x x851.7 i 1 i Drainage and utility easements • ,v:_per plat of WATERS EDG -? ? 850 x J 5 r s ? k ?- •°-Buildinq setback lines 848.4 0 N '35 LEGEND • lron Monument Found -S-Sanitary Sewer -sr-Storm Sewer -w - Watermain MHQ Manhole inv. Inverf Elevation 7_718ituminous Surfoce _.-Overhead Wires 960.ix Denotes Existing Elevation so. . Denotes Proposed Elevation --Denotes Proposed Surface Droinage ? Denotes Hub Area = 13,747 squore feet (0.32 acre). °--Grade swale or construct retaining walf ta provide drainage araund house 85] 1 '"'? Address: 1458 Englert Road ? House Type: Rombler walkout ? M O M ? ? Z I- /? ?p 87.00 '.'a°tia?rL? 84s.o '_ L?ll?l?i?; for Lots i, 2, 4, 5, 6 and 7: 22,6191148,926 = 15.199 Allowed = 25% I hereby certify that this is a true ond correct representation of a survey of the boundaries of the land a6ove described and of Y?pMj?1?Hiqf a proposed house. JvID .? ; • ''. ;F Dated this 7th day ot July, 2QQ'4.p : ? LICENSED ' R HDER & ASSOCIATES, INC. LAND : - ' SUFVEYOR • 42616 s.Q David C. Craigie, Land Surveyor • F,`n Minnesota License No. 42618 ??ij?F•AqjtNN` Revised: July 21st, 2004 - Update perj?HM?nents Revised: July 27th, 2004 - Update House design Rehder and Associates, Inc. CIV1L ENGINEEAS AND LANO SURVEYORS ]LIO FeEmol orire • S.R. YIO •Eagrn, Mlnnsaata Phme (851) 452-5051 o CN M ?i ? 0 ? ? 855.8 ,c y ?. h ?l ? X ? 0 ? ?6" Water of oroo. line Proposed House 5 J08: 034-1845.02S 1'1 Building Permit Survey for: McDONALD CDNSTRUCTION, !NC_ LEGAL DESCRIPTION Garage Floor Elevation = 857.45 Lot 5, BIoCk 1, WATERS EDGE, Top of House Foundotion Elevation = 860.75 Bosement Floor Elevotion = 852.04 accordrng to the recorded plat thereof, Dokota County, Minnesota. I 8" -W ENGLER T ROAD - ......6° wuter af -S prop. line Sanitary sewer service ... = 844.0 /eet (Per plan) -°Grode swale or construct retoining wall to provide droinage around house Address: 1458 Englerf Road House 7ype: Rambler walkout Scale: 1 inch LEGEND • lron Monument Found -S-Sonitory Sewer -ST- Storm Sewer -W- Watermain MHQ Monhole inv. Invert Elevotion Oeituminous Sur/ace -_-Overhead Wires 960.Ix Denotes Existing Elevation so. . Denotes Proposed Elevation -Denotes Proposed Surface Drainaqe O Denotes Hub Area = 13,747 squore feet (0.32 acre). ?w Pt Cumulative impervious sur(ace coverage for Lots 1, 24 5, 6 and 7: 22, 619/148, 926 = 15.199 Allowed = 25% I hereby certify that this is a true ond correct representation of a survey of the boundaries of the land above described and of the lo;atianof a proposed house. `\`??\O C. CqA Oated this 7th day of July, 2004?.`OP?•"'' ? REHDER & ASSOCIATES, INC. - ' LiCENSED ' LAND SURVEYOH 42618 vid C. Craigie, Land Surveyor ???9•., , Minnesota License No. 42618 '?.'0 pF"'iNN? Rehder and Associate1??r1L: CINL ENGINEERS ANO LANO SURVEYORS 3IIO FeEerul Oriw • Sulla 210 •EOqan. YNnaola ?one (831) 132-5051 eyi 5?I N& ?KcIeCTII 4?CW C-F rew $lfi JOB: 034-1845.028 roP as3. 75 I - Inv. 845.37 - 15-ST MH PERMIT City of Eagan Permit Type:Building Permit Number:EA142505 Date Issued:05/05/2017 Permit Category:ePermit Site Address: 1458 Englert Rd Lot:005 Block: 001 Addition: Waters Edge PID:10-83475-01-050 Use: Description: Sub Type:Reroof Work Type:Replace Description:Does not include skylight(s) Census Code:434 - Zoning: Square Feet:0 Occupancy: Construction Type: Comments:Please print pictures of ice and water protection and leave on site. Carbon monoxide detectors are required within 10 feet of all sleeping room openings in residential homes (Minnesota State Building Code). Valuation: 4,000.00 Fee Summary:BL - Base Fee $4K $103.25 0801.4085 Surcharge - Based on Valuation $4K $2.00 9001.2195 $105.25 Total: I hereby acknowledge that I have read this application and state that the information is correct and agree to comply with all applicable State of Minnesota Statutes and City of Eagan Ordinances. Contractor:Owner:- Applicant - Tino Hing 1458 Englert Rd Eagan MN 55122 (612) 518-9876 Galvin Home Renovations Inc 6043 Hudson Rd, Suite 140 Woodbury MN 55125 (612) 518-9876 Applicant/Permitee: Signature Issued By: Signature