Loading...
1630 Harbour Pt2004 RESIDENTIAL BUILDING PERMIT APPLICATION City Of Eagan 3830 Pilot Knob Road, Eagan MN 55122 Telephone # 651-675-5675 FAX # 651-675-5694 c.?aU(0 S-36 New Consimdion Reauiremenis 3 registered site surveys showing sq. fl. of lot, sq. R. of house', and all roofed areas RemodeVReoair Reauiremenls 2 copies of pian Ce11 Gf 5wve!!R¢e? --.:Y N (20%marzimum lotcoverage albwed) 1 set of Energy Calculations for heated additions 7h9g At2sPlan.?OCd Y _N 2 copies of plan showing beam 8 window sizes; poured faund design, etc. . 1 site survey for addilions & decks Tree Pres Ret?uued 'Y Pl 7setofEnergyCalalafions Addifion-indicateifon?sitesepficsysfem D?SIIeSepA?:?yst0m Y_N? 3 copies of Tree Presenralion Plan if loi plafted afler 711N3 Rim Joist Delail Oplions selection sheet (bldgs with 3 or less units Date Site Address Construction Cost 4.01 UniUSte # Description of Work n: /P v N Y- / - Multi-Family Bldg _ Y_ o N Fireplace(s) _ 0 _ 1 _ 2 PropertyOwner ??,,whn Y /21&1-Aa4 L?IC Telephone#(G3S'a Contractor Address State Zip City J ? ?.Lv1 ? ? Telephone # (c'$:2) COMPLETE THIS AREA ONLY IF CONSTRUCTING A NEW BUILDING - Minnesota Rules 7670 Cate¢orv 1 Minnesota Rules 7612 Energy Code Category , Residentlal Ventilatlon Category 1 Worksheet • New Energy Code Worksheet (Jsubmissiontype) Submitted Submitted . Energy Envelope Calculatlons Submitted Have you previously constructed a building in Eagan with a similar plan? _ Y _ N if so, 25% plan review fee applies. Licensed Plumber Mechanical Conhactor Sewer/Water Contractor Telephone #( Telephone #( Telephone #( I hereby apply for a Residential Building Permit and acknowledge that the information is complete and accurate; that the work will be in conformance with the ordinances and codes of the City of Eagan and the State of MN Statutes; I understand this is not a permit, but only an application for a permit, and/jork is not to start without a permit; that the work will be in accordance with the approved plan in the case of w r which requires a review and approval of plans. ,/ %,?-r-/l Z-?l ei k\ Applicant's Printed Name U A plicant's Signature OFFICE USE ONLY Sub Types ,,.. - ? 01 Foundation ? 07 05-plex ? 13 16-plex ? 20 Pool ? 30 Accessory Bldg ? 02 SF Dwelling ? 08 06-plex ? 76 Fireplace ? 21 Porch (3sea.) ? 31 Ext. Alt - Multi ? 03 01of_plex ? 09 07-plex ? 17 Garage ? 22 Porch/Addn.(4-sea.) ? 33 Ext.Alt - SF ? 04 02-piex ? 10 OS-plex ,J2-18 Deck ? 23 Porch (screenlgazebo) ? 36 Multi Misc. ? 05 03-plex ? 11 1 D-plex ? 19 Lower Level ? 24 Storm Damage ? 06 04-plex ? 12 12-piex Plbg_Yor_ N ? 25 Miscellaneous Work Types New ? 35 Int Improvement ? 38 Demolish Interior ? 44 Siding ? 32 Addition ? 36 Move Building ? 42 Demolish Foundation ? 45 Fire Repair ? 33 Alteration ? 37 Demolish Building` ? 43 Reroof ? 46 WindowslDoors ? 34 Replacement 'Demolition (Entire Bldg) - Give PCA handout to applicant 00 Valuation ?D-o v0- Occupancy MCESSystem Census Code Zoning City Water SAC Units Stories Booster Pump # of Units Sq. Ft. PRV # of Bldgs Length Fire Sprinklered -? Type of Const Width REQUIItED INSPECTIONS _ Fooungs (new bldg) _ FinallC.O. _ Footings(deck) _ FinaUNo C.O. _ Footings(addition) _ Plumbing Foundation _ HVAC Drain Tile Other Roof Ice & Water Final Pool _ Ftgs _ Air/Gas Tests Final _ Framing _ Siding _ Stucco _ Stone _ Brick _ Fireplace _ RI. _ AirTest _ Final _ Windows Insulation _ Retaining Wall Approved By: 8uiiding Inspector Base Fee Surcharge Plan Review MC/ES SAC City SAC Utility Connedion Charge S&W Pertnit & Surcharge Treatment Plant License Search Copies Other Total ? * * * y* PIONI 8 T* Ipt * * Certific(ite of Survey for: '?0 SUfl12YIXt5 • CINL rinrvue?s• usosc RBOR aAQ?IES?IN_-- - 16J0 IIAR80UR POIt4T FAGAtJ, MIIdNE507A ??,84 -; , h8f'30'33"yy 907.7 N: ? 08.O?L, .. . 1-10USE TYPE 2- STORY WALKOUT ? 1511 l` to \ M f ? LOT AREA = 12,825 sq. ft. FiOUSE AREA = 2,045 sql ft. COVERAGE =15.9% SERVICE ELEV.= 898.8 (PLAN) BENCH'MARK TOP OF SPIKE-- ELEV.=910.04 7 n ? r 3 910.0 ? 3g? TU ToF 903.6 /909.1 i'?lU'I N 89'00' S1 "E 906.9 `1?11.61 U NOTE: PROPOSEO GRAOES SHONM PER GRADING PLAN BY: dftV! NUIE: BUILUING UIMENSIONS SNOWN ARE FOR HORIZONTAL NJD V?'RTICRL LOCATION OF STRUCNRES ONLY. SEE ARCHITECIUAL PLAIJS FOR BUILDING AAIO FOUNOATION DIMENSIONS. NOTE: NO SPEQFIC SDILS WbESiIGA710N HAS BEEN COMPLETED ON TFIIS L'JI BY 7HE SURVFYOR. THE SUITA6ILITY OF SOILS TO SUPPORT THE SPECIFIC IIDUSE nn0^OS.C {.. ?.v: AiC 'E SF ° _ UtJolu'llTY Gf IiSE SURVEYOR, NOTE: THiS CERTIFlCATE DOES NOT PURPOftT TO 5{ 7 ( ? ? r>..,) ? ?. = ?3 07. j °ROPosEO iiousE rLE7Vp, ?io'N L6iN'EST FLOOR ELEVATION: ? (? TOP OF BLOCK ELEVATION: GARAGE SLAB ELEVATION: TQR hL Inntin?i'I' ELr?,in?r!.%;.i._"_'____ EASEMENTS OTRER TFIAN X 000.00 OENOTES E%IS71NC ElEVATION 7HOSE SHOWN ON 7}?E RECORDED PLAT. SHOW ( 000.00 ) f1ENOlES PROPOSEU ELEVATION NO7E: CONIRACTUR MUST VERIFY DRIVEWAY OESIGN. --- DENOTES DRAINAGE AfiO UTILIIY EASEMENi NG7E: HEARINCS SHOWIJ ARE BASED ON AN ASSUMEO DAIUM - DENOTES DRAINAGE FLOW DIRECTION , ---? DENOTES SPIKE -B OENOTES OFFSET HUB WE HERE6Y CERTIFY TO AARBOR HOMES INC. Th1AT THIS IS A TRUE AND CORRECT REP,R.ESENTATION OF A SURVEY OF THE BOUNDARIES OF: LOT 23, BLOCK 1, MURP-IY. FARM 3RD ADDITI7N DAKOTA COUNiY, MINNESOTA IT DOES NOT PURFORf TO SHOW IMPROVEibiEiV';5 OR fNCtiOACHMENTS, EXCEFT AS SHOWN, AS SURVEYEG 6'( ME OR UNOER MY DIRECT SU?ERVISION ftilS 17TH DAY CF FEBRiJARY, `L004. R10NFFy? EidGINEGRING, P.A. iIGNED: ?/ SCALE : 1 INCH = 30 FEET ' REVISEO OZ-23-(3ti STAKED HOUSE BY:?/? •? ? ? --- -?`- : ?-_. 25 iD04?1pp5?SIdO\TJW rIf1?E Peter J: Ilawkinson Reg. No.. 427.99 I l,_(_v 4p 1 I l? ??\ o,. _ BENCH MARK TNFE L015 20 Ac 21 BLK 1 ELEV.=913.06 i !r,? 1)3 ? v ??F ?, AO g;,•, ,, . 9!0.3 ' 9:0.5 ?p sitz io. PRppAED 5 m RIVE?jyY a ? BENCH MARK -----TOP OF SPIKE siz.e ELEV.- 12.67 912.7 \ 5.0 3 41 9- 5i) ?i I PER PLAT ` -- - - .b\o.'_ /\A SO \?f\o a ° 90J, ? L?q 90 .4 ? ? ? ?y M? ` ?t- ? xaos. ./ .? o J ' o-l C!8 y? O • 909.9/, °o ? .6 90fi x `23 04 . Z? Is DRAIUAGE & U1ILITY _,?:'?/ EASEME"'-? 2422 Enterprise Drlve Mendulu Ileights, MIJ 55120 E4GINEEflS (851) 881-1914 FAX:BB1-94B6 avcinECrs -.. iwc wuy 10 N E ?•)5 1 liyh Bloine, IdN b54.74 . . (783) 783-188U FA%:783-1883 Address: 1630 Harbour Pt Lot: 23 Block: 1 Subdivision: Muxphy Farm 3rd THE FOLLOWING ITEMS WERE/NERE NOT COMPLF.TE AT FINAL INSPF,CTION ON Zip:55122 Yes No Comments Final grade - 6" from siding Permanent ste s- ara e k Permanent ste s- main entry Permanent drivewa Permanent gas Retainin Wall or 3:1 Mzx Slo e Sod/Seeded lawn Trail/curb dama e Porch Lower level finish Deck Fire lace • Verify with your builder that rooF test caps from the plumbing system have been removed. • Tum off water supply to the outside lawn faucets hefore freeze potenfial exists. • Call the City's Engineering Ueparhnen[ a[ 651-675-5646 prior to working in righUOf-way or installing irrigarion system. Y BUII.DING INSPECTOR: Z?L CONTRACTOR: Aarbor Homes 1244 Canterbury Rd #304 Shakopee, MN 55379 t-6-r a'3 'f5 1 cD C-?_ I yY??v ti F?\f vv. 3r ?-? ?31?8? ?p t?3tp?4??&Sln?`1.?r1 2004 RESIDE NTIAL BUILDING PERNIIT APPLICATION , City Of Eagan itiLl? LQ3?'?? • ' 3830 Pilot Knob Road, Eagan MN 55122 QP (tr j jp?7 -??b `? • Telephone # 651-675-5675 FAX # 651-675-5694 ?. ?--?-? p?? New Construciion Reauirements RemodeVReoair Reauirements ?31z1 fo L 3 registered site surveys shaving sq. ft. of lof, sq. ft. of house; and all roofed areas 2 copies of plan (20% maximum bt coverage allowed) 1 set of Energy Calculations for heated addilions i ? 2 copies of plan showing 6eam & windovr sizes; poured found desig ,rJ'?tc. __{_ ? ?lsile-syrvey for additions & decks ( t8s 1 set of Energy CalalaUons ???17 ? 'J Affd'd7?n - indicafe if on-sde septic system ? - ? - - 3 oapies of Tree Preservation Plan if lol platted after 711193 ?.Y,.? eV-JP Rim Joist Depil Options selection sheet (61dgs with 3 or less units ? Cvh? Date ') / 3 Site Address 1(0100.Y?[lQU Construction Cost oc, I ?191 h'{' UniUSte # Description of Work J 1,r\?;14 11? f _ cxn?'? ? w ?{ (?' ? Multi-Family Bldg _ Y? N Fireplace(s) _ 0 2 Property Owner Dor ?aa r TT U Yl-\, =h 'L ? Telephone # ( a51) Contractor ? G YA,\o r Ilu rti ,p S hC ` , Address a ? () (_A_OU State N n( i CI? Cir?c? ?i Ol G P 7 Zip S?So q \ D C,` ?QCity Telephone #(qs?_) ?3 3-a(n C?j COMPLETE THIS AREA ONLY IF CONSTRUCTING A NEW BUILDING ? Minnesota Rules 7670 Cateeorv 1 Minnesota Rules 7672 Energy Code Category Residential Ventilation Category 1 Worksheet • New Energy Code Worksheet (Jsubmissiontype) Submitted Submitted • Energy Envelope Calculations Submitted Have you previously constructed a building in Eagan with a similar plan? _ Y _ N If so, 25% plan review fee applies. Licensed Plumber ?\f-S51 Q h C 1LG J^; V,A e r UlY'@S Telephone #(65'1) 6QSfI "$a b?. Mechanical Contractor Sewer/Water Contractor Telephone # (95a )-?f?= Telephone # R5o ) I hereby apply for a Residential Building Permit and acknowledge that the information is compWand aecurate; that the wark will be in conformance with the ordinances and codes of the City of?Ea$aR-aiicl- ft=Statc--of MN Statutes; I understand this is not a permit, but only an application for a rmit, and work is not to start without a permit; that the work will be in accordance with the approvepl?plan in the c?ise of work which requires a review and approval of plans. 5? ApplicanYs Printed OFFICE USE ONLY Sub Types ? 01 Foundation ? 07 OS-plex ? 13 16-plex ? 20 Pool ? 30 . Accessory Bldg ai1 02 SF Dwelling ? OS 06-plex ? 16 Fireplace ? 21 Porch (3-sea.) ? 31 Ext. Alt - Multi ? 03 Ot of _ plex ? 09 07-plex ? 17 Garage ? 22 Porch/Addn. (4-sea.) ? 33 Ext. Alt - SF ? 04 02-plex ? 10 OS-plex ? 18 Deck ? 23 Porch (screen/gazebo) ? 36 MuRi Misc. ? 05 03-plex ? 11 10-plex ? 19 Lower Level ? 24 Storm Damage ? 06 04-plex ? 12 12-plex Plbg_Y or _ N ? 25 Miscellaneous Work Types x 31 New ? 35 Int Improvement ? 38 Demolish Interior ? 44 Siding ? 32 Addition ? 36 Move Building ? 42 Demolish Foundation ? 45 Fire Repair ? 33 Alteration ? 37 Demolish Building* ? 43 Reroof ? 46 Windows/Doors ? 34 ReplaCement "Demolition (Entire Bldg) - G iva PCA handout to applicant Valuation / Census Code /eg/ SAC Units O/ # of Units # of Bidgs Type of Const ? Footings (new bldg) _ Footings (deck) Footings (addition) ? Foundation Drain Tile Roof - _,t Ice & Water „ Final ? Framing Fireplace ?L R.I. _,fAir Test _t Final ? Insulation j Approved By: Base Fee Surcharge Plan Review MC/ES SAC City SAC Utility Connection Charge S&W Permit & Surcharge Treatment Plant License Search Copies Other ToWI Occupancy 4-3 Zoning 9-1 Stories Sq. Ft. Itl Length 3 7 Width '26 MCES System City Water - Booster Pump - PRV Fire Sprinklered - REQUIRED INSPECTIONS # Final/C.O. FinaUNo C.O. _ Plumbing _ HVAC Other _ Pool Ftgs Air/Gas Tests Final _ Siding _ Stucco je? Stone _ Brick _ Windows _ Retaining Wall Building Inspector 7- y -? 3 ??---- ? ;- v ? s% ?crw/L ? ?a J=LQ3N poncii /A 53 !-?/& 15? 12.93I?1'@ a"y°i &I6 'Tk `' l55-0Q 30`' J53`s3 ( g?? 1-t ? /?? ?S Shaetl EXFERTOR EtJVEtAPE AVE&r16E'Y3" C(7AhPUTAIZON OWNER The M¢yer Residente P4AN NO. 0-1205-3 SiTE ADDRE55 1630 Hnrbaur Poim - Eagan, Mn .. CONTRAGTOR Aarbor Homes, Snc. bATE - Dec.-03 OETERMINE WOlYKZN6.SQUAfiE'FOOTA6£ 1. Total exposed wdl area 3556.45 . sq. ft. x 11 = 391.21 2. Total rouf / ceiling aren 1354,00 sq. ft, x,fl26 = 3520 3. Total floor cant. aren 0.00 sq. ft. x.p26 = 0.00 (over unheatedenclosedareos) 4. Total flnar cont. area 5.00 sq. ft x.OB = 0.64 (over unheated eacposcd areas) 5. Totatexposedwnllnr¢oabovetfiefloor. '-----'--"---'-'-------'---' 3176.22 o. Total wdl window area . . . ... . . ... .. .. . . :... _ .... ... .. . . ... .. .... . . 429.77 b. Totaldoor area 37.82 c. Total sliding glass door area ...... .... ..... ... ... .. ... . ..... . .. . . .... . 146.55 d. 7otalfireplace area ............... ........................... ........ 0.00 e. Total wallframtng area ( ave. SO% ) ..................................... 317.61 f. Total net wall areo above the floor . . . . . .. . . . . . . . . . . . . .. ... . . . : . . . . . . . . . . 2284.27 y. Total wim joist area. . . . . . . . . . . .. . . . ?. . . . . .. . . . . : . . . . . . . . . . . . . . . . . . . . . 314.00 T07AL EXP45ED FOUNUATZON AREA . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66.33 h. Totalfoundotion window area ................. _............. ......... i. Total net foundatinn area ..... ... ........... . . ... ..... _ . .. . ..... . . .. betermine "U" vokie of each vrotlsegmeM a 429.77 x"U" 0.32 ? b. 37.82 x "U" 0.40 = c. 196.65 x "V" 0.32 = d 0.00 x "U" 0.00 = e. 317:61 x "U" 0.09 = {. 2284.27 x "N" 0.04_ g, 314.00 x "U" 0.04 = h. 0.00 x "U" 0.32 = i. 65.33 x "U" 0.08 = 0.00 LF 21 13].53 15.13 34.13 O.W 28.59 98.72 12.77 0:00 5.05 ' 6 ....................... _..............Total: .. 332A2.'.. If i+em #b is the same as or less than item#1 you have mefi the curreM snergy code5. '.. 2 MGAR 2.16008 A AND O. TOTAL pfP058D ROQF / CE2LIN6 AREA- _ _ ' ' - - ' ' - - ' ' ' " - - ' ' ' - ' 1354.00 ,... Page 1 Shee#1 j. ToYal skylight areu .. . .. . . . . . . . . . . . . . . . . . . . . . . .. . . . . .. . . . . . . . . . . . .4 0.00 k. Tofiol fl¢t roof ! ceiling framing area ... . . . . . . . . .. . . . . . . . . . . . . . . . . . . . . . . 195.40 L Total net fiat roo# / ceiling area ... . .... .... .. ... . .. .... . ... . .. ...... .. 1216.60 Determine'"U" value far euch raof i ceiling segment j. 0.00 x°U" 0.00 = 0.00 k. 135.40 x"V" 0.03 = 3.34 1. 1238.54 x"V" U2 = 26.34 7 .............................................. Tatal: ? 29.93 Ifi item #T is the same bs ar tess thoa item #2 you hqve enet 1h¢ ¢nergy code. 2 MCAR 1.16008 A ANb O. TOTAL FLdOR CANT. AREA ( sncivsed )._ ' ' ' ' " ' ' ' ' ' ' ' ' _ ' " ' ' " ' ' 0.00 a. Totalfloor cont.framing area(avq.10%) ................................. a.DO p. Totn3 net insulated flaor / tant. areu .... ..... ..... . .. 0.00 batwmtne "U" wlue far ench fbor ! cnrcr, sagment o. 0.00 z"U" 0.07 = 0•00 p. 0.00 z"l1" 0.03 = 0.00 B ............................................... Totat: ?.00 Tf item #9 is the same as or iess ihpn item #3 you have met th¢ energy code. 2 MCAR 4.16008 A ANO O. TOTAL FIAOR CpNT. AREA ( exposed ). - ' ' ' ` - - - ' ' - ' _ ' - ' - ` ' - ' ' ' 8.00 q. Total fbor cant. framirig are,a (avg. SII%) . . ... . . . _ . . .. ... ....... ... .. ... 0:80 r. Total net inSUlated itnor ! cant. orea . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7.20 Oetermirx "U" vaiue for aach fioor / uM. segment q. 0.80 x"U" 0.03 = 0A2 r. 7.20 x"U" 0.03 e 020 9 ................................................ Total: 6.2z If item #1;9 is the sgme as or Iess ihan item #4 you hnve mef the energy cade. 2 MCAR S?at6D8 Fr`AN?.1 U. I HEREBS' P. FY AT S NAYE CALCULk'SEO SHE "LP' FACTORS AIJD "R" VAWES Vk1EitEIN AND fiiAT S}iE SUILDING HERE 06 R EKCEEDS THE STATE Of M2NNESOSA ENER6Y CONSERVATION ACT. Page 2 Sheetl OETERM2tJE"U"VALUES TNROU6H 5TUD WITH SIOIN6 SHEET ROCK Enterior air 0.68 Shezt Rock 0.45 Thermo-Break 0 5tud 6.93 Sheathing 2.06 5iding 0.78 F-xterior AIr 0.17 Total"R" 11.07 1/R = "U" 0.0903342 TNROU6H INSUTATTON WiTN SIpING & SWEET ROCK Interior Air 0.68 Sheei Rock 0.45 Thermn 6reak 0 Insulation 19 Sheathing 2.06 Siding 0.78 Exterior Air 0.17 Totsal "R" 23.14 1/R = "U" 0.0432152 THROUGH GEZLIN& MEMBER Interiar Air 0.68 Sheet Rack 4.58 Ceiling Member 4.35 Tnsulatinn 33.75 Still Air 0.61 Total"R" 39.97 1/R = "U" 0.0250188 THROU6H CEILINfi INSUI.ATtON Interior Air O.b$ 5heet Rock 0.58 InSUlation 45 ToTal "R" 4626 Page 16 Sheetl 1/R = 'U' 0A216169 TNROUGH CONCRETE 9LOCK InfierioP Air 0.68 Concrete Block 128 Insulation il Shee4 Rock (npt.) ? ExterioP Air 0.17 Total"R" 1313 1/R = "U" 0.0761615 THROU6H RIM TOI57 Lntarior Air 0.69 InsulaTion 14 Rim Saist 1.89 5heathing 2.06 Siditg 076 Exterior Air a.P Totut "R" 24.58 1/R = "U" 0.0406835 "U" value for window 0.32 "V" vnlue far doors 0.4 "U" value for Patio Drs. 0.32 THROUGH CANT. @ MEMSER (enclosed) Inierior Air 0.68 Finish FEooring 123 Vnderlayment fl Plywoad 0.93 Joisi 1i,56 STill Air 0.61 Total"R" 15.01 IJR= "U" 0.0666223 TWROVGH CANT. C INSULATLON (encto5ed) Page 17 Sheet1 Tntertor Air 0.68 Finish Flooring 1.23 Underim/ment 0 Plywoad 0.93 InsulaSion 30 SheeY Rack 0.55 Still Air 061 Tatal"R" 34.03 f/R-"U" 0.0293$58 THROUGN CANT. @ MEMBER (exposed) Znierior Air 0.68 Pinish Ploorittg 1,23 Underlayment 0 Ptywood 0.93 7oist 12.56 Sheathittg 20.6 Soffit a.7$ Exteriar Air 0.17 T6ta1 „R" 35.95 l/R = "U" 0.0276164 THROU6H CANT. @ INSUlATfON (expased) Interior Air 0.68 Piaish Flaor 1.23 Underloyment a Plywood 0.93 Insulation 30 Shenthing 2.06 5offit 018 Ezterior Air 0.17 To+et"R" 35.85 tJR = "U" 0.027994 Page 18 Development Lot Number Z3 Block Number ( Address ?63d t?'?'?(Z13?1K Tat n1-t Builder ?F p"1Zi?OlZ. ??mf'il t Z(\JE- PHONE NUMBER: ct YZ - 233 " Zb 0-0 CONTACT: U ??O NYC STCI 1V ??J 1) Tree Protection Reauirements: ? Tree Protection Fencing Installed On Site Oak Tree Pruning (Immediately seal wounds during April 1 to July 31) Therapeutic Pruning Retaining Wall Other: Reulacement Trees: ? Not Required As Follows: Attachments: ? Yes No Additional Notes: ?-- H:\ghove12004f1e5treepres\Tree Preservation Plan Summary-2004 (PLEASE READ ATTAGHMENTS) #** ** MendototHeghts,OMN 55120 * PION6HR ?uio wAVCmvs oH? Exararrs (651) 881-1914 FA%:881-94B8 *efle n BOP Tn9 uxoriumEns. ?moswre,wouhcrs 615 Highway 10 N.E. {t * * * Blaine, MN 55434 (767) 787-1880 FA%783-18BJ Certificate of Survey for??ARBOR HOM S, INC ? 1670 HARBOUR POINT EAGAN, MINNESOTA 1 ? I ? 12.84 ?a?----_---- N86'30'33"H( j ;' p - - - - - ? I 90).] ? BOB.O m - oe.s BENCH MARK m 7NH LOTS 20 dc 27 BLK 7 908. g m4 ? ELEV.=913.06 609 0 L ? Z HOUSE iWE S AI 'O 908.6 2- STORY WALKOUT %? O M !r 1 ?G.f? x?S,O p7 LOT AREA = 12,825 sq. fL \ HOUSE AREA = 2,045 sq, ft, y? ?A S!a COVERAGE =1$.9q, ? SERVICE ELEV.= 898.8 (PLAN) 7I /?/T r ` 910.1 ? ? 810.3 810.5 OPNOF SPIKE--?? EIEV.=910.04 • ?? I ?C ? p ? l0? e/Li.z ? 6}910.0 `0 ' `? I0.8? . 3 919?n 'POR??z g7¢¢ , ORIED 5 m n ?`t h? 40.1 915.e qY n`n h O ry I .?? PROP ro BENCH MARK -- N?p C9a?¢ ?? ?.\ HOUSEED hi 1 Y97 70P OF SPIKE .>eiz.e ELEV.= 1,2.67 3 vas? ., soz? 7. 5.0 [o oo° o 04 RqCf o a ? ? e07. qab '`° . sa oi M1 W'O 15 N 44. n+ ? x905.0 5/ sl?f / vi? I 10.?5 9 O ?9?0-? /?Z x N 908.8 i L J ?-- BOJ .6 Vo9.2) DRAINAGE TIL ? P l - vou.i N89'00'51"E . 1-P14C 906.9 J , N vN 0.%LO) v PROPOSED U ON NOtE PROPOSED CRPDES SHOMN PER dUDINC PLVI BY: 8RW LOwEST ROOR ELEVATION: NOM: BUIWING ARCHITECIUA?LRPL?S ?FOR BU?INO u?D OI 70P OF BLOCK ELEVA¶ON: FWNOAlION OINENSIONS. 5? 4 7 NOTE NO SPEpFlC SqLS IAbESTGAl10N HAS BEEN COUPLEIFD ql GARAGE SLAB ELEVATION: tH15 LOT BY TfE ' SUR?EYIXi. 1HE SUITABI?tt OF 50¢.5 TO SUPPORT 1HE SPEtlFlC HWSE TOB ? LOOKOUT ELEVA¶ON: PROPOSFll i5 NOT.'1HE RESPONSBttItt Of E SURUEVOR. xalE; T1I5 CEftiiFlCATE DOES NOT PUqPOqT iiOw EASEMENTS OIHER THnN % 000.00 OENOTES EYlSIINC ELEVATON TMOSE SHOVM pH IHE RECIXVOE? PIAi. ( 000.00 ) OENOTES PflOPOSED ELEVATON NOTE CONTRACTOR MUST VYRIFY ORIYEWAY DE9GN. -- DENUTES URNNAGE AND U?UTY EASEMEfIT DENOiES ORAINAGE ROW DWECPON NOIE BEARINGS SHOMTI ARE 8.15ED Ox ,W A5511NE0 DAIUM ---?- pE}10TE5 SPME -@- DENOlES OfFSET HUB WE HEREBY CERTIFY TO AARBOR HOMES INC. 7HAT THIS IS A TRUE ANO CORRECT REPRESENTATION OF A SURVEY OF THE BOUNDARIES OF: LOT 23, BLOCK 1, MURPHY FARM 3RD ADDITION DAKOTA COUNiY, MINNESOTA - ?? IT DOES NOT PURPORT TO SHOW IMPROVEMENTS OR ENCROACHMENTS, EXCEPT AS SHOWN, AS SUR YEOVE BY ME OR UNDER MY OIRECT SUPERVISION THIS 17TH DAY OF FEBRUARY, 2004. SIGNED: ION ENGINEERING, P.A. SCALE : t INCH = 30 FEET y RE?ASED 02-23-04 STAKED HOUSE BY: i 2825 100410005 SMD TJW ? zlZq?? Peter J. Hawkinson Reg. No. 42299 ? _'_ ? LOT SURVEY CHECKLIST FOR RESIDENTIAL BUILDING PERMIT APPLICATION we ??" • - ? • PROPERTY LEGAL: Z-d ? ?3, Rlmr ? I MGr?Ohti riev., Z?? DATE OF SURVEY: ? Z-Z7 -O? LATEST REVISION: _Jf? lr Dy d a? c A t U ? O `z Q DOCUMENT STANDARDS IK ? ? • Registered Land Surveyor signature and company 'K ? ? • Building Permit Applicant 1< ? ? • Legal description g ? ? • Address jK ?? • North arrow and scale k a ?? (q ? 0 • House type (rambler, walkout, split w/o, split entry, lookout, etc.) tyCQ ? jn? ??? • Directional drainage arrows with slopelgradient %(WCS'f S1? ?!t ? qft • Proposedlexisting se_ w?er and water services & inveR elevation "/.e.¢noa't- rc'j,ui etclf) ? ? ? • Street name X ?.0b. • Driveway (grade & width - in R/W and back of curb, 22' max.)(QX4e,,%d </D? ? ? ? • Lot Square Footage ?e-Galc ? ? • Lot Coverage ELEVATIONS Existin ? ? ? • Sewer service (or Proposed) 00 ? • Property corners ?? 0 • Top of curb at the driveway and property line extensions .? ? ? • Elevations of any existing adjacent homes ?)( ? • Adequate footing depth of structures due to adjacent utiliry trenches ? 'X ? • Watervvays (pond, stream, etc.) Prooosed ? ? • Garage floor ? ? ? • Basement floor pS' ?? • Lowest exposed elevation walkouUwindow) ? ? 0 • Property corners ?? ? . Front and rear of home at the foundation PONDING AREA (if aeolicable) ? ? ? • Easement Iine ? ? ? • NWL ? ? ? • HWL ? ;K ? • Pond # designation ? ? • Emergency Overflow Elevation ? ? • Pond/Wetland buffer delineation DIMENSIONS ? ? 13 • Lot Iines/6earing5 & dimensions ?? ? . Right-of-way and street width (to back of curb) ?? • Proposed home dimensions including any proposed decks, overhangs greater than 2', porches, etc. (i.e. all structures requiring permanent footings) ?? ? • Show all easements of record and any City utilities within those easements ?? ? • Setbacks of proposed structure and sideyard setback of adjacent existing structures ?)< 0 • Retaining wall requirements, if any Reviewed: ? 3- 9- o Name Date G:lFORMSlBuilding Permil Application Rev. 12-16-03 *4t * - * PION . . *a- R-9- rn T y *? T Certificate of Survey for: m?vV+ 1p ?p - - ? ? "sm.7 ? i 908.0 ci o 908 ? 080 9 4 ? 51? 10 1830 HARBOUR POIN7 EAGAN, MINNESOTA 12.84 N86'30' HOUSE TYPE 2- STORY WALKOUT LOT AREA = 12,825 sq. ft. HOUSE AREA = 2,201 sq. ft. ? COVERAGE =17.27 ? SERVICE EIEV.= 898.8 (PLAN) }kYTE'. G??^DVT R.£W. I fjy G?l'?( 910.1 ? BENCH MARK TOP OF SPIKE--_ ELEV.=910.04 wc? ? 3 e) Y „? 0 h f_J a? ?-- , 903.6 909.1 (9 ° 1 U 2422 Enterprise Drive Mendota Heights, MN 55120 s- aex a+anccRS (651) 881-1814 FAX:881-9488 UNOSCnPE APqII1EL15 625 Highway 10 N.E. Bloine. MN 55434 (783) 783-1880 FAX:783-t883 A \ \ \ ? ? k4u•t , , , a0.- M ai? /??o ??Po.._ x ??oG? ?°o ? Q R? ?O A ?Sl a TNH L0? 20 &A21 BLK 1 ELEV.=913.06 ?se&( ? eo"os ?? C? ?/ ?A 0.3 - 910.5 r - 2j• ? /p 0y ? /0 10 OR,rK,AED , ? y! >} ??_ p4.k .t? p° \ ° \?ARqGf ) 907. q 6 ? °• s. ? I w?.x/pb ¢ 15• 9 D I 44.o0 I/ xsos.o? 906.6 I 2 7 J ?/ ? , ??' I ?1IN DRAINAGE & UTILiTY EASEMENT PER PLAT N89'000 51 "E h v • . (`?o$. .s lL? ?wce 111.61 906.9 (qDB.3:9 Nlax':rr,?rr, G!c,r,es or,L:-_ Vvill Be kayuirzd YNbTE!'PROPOSED`GRAOES'SHDNTI PER GRAOINC PLAN BY: BRW NOTE: BUILDINC OIMENSIONS SHOWN ARE FOR NORIZONTAL ANU VERTICAL LOCA710N OF STRUC7URE5 ONLY. SEE ARCHIIECNAL PLANS FOR BUILDING AND FWNDAl10N DIMENSIONS. NOIE: NO SPEqFIC SOILS IN4ESTIGATION HAS BEEN COMPLE7E0 ON 7HIS LOT BY 7HE SURVEYOR. 7HE SUITABILITY pF SOILS TO SUPPORT 7HE SPECIflC HOUSE PR0POSE0 IS N0T 7HE ftESFONSIBILITY OF 7HE SUR4EYOR. NOTE: 7HIS CERTFlCA7E OOES NOT P ROPO ?HO S V T N LOWEST FLOOR ELEVATION: 907 TOP OF BLOCK ELEVATION: 9)s•? GARAGE SlAB ELEVATION: 914 7 T08 0 LOOKOUT ELEVATION: URPORT TO SHOW EASEMENTS OiHER THAN % 000.00 DENOTES EI(ISTING ELEVATION THOSE SHOVM ON THE RECORDED PIAT. ( 000.00 J DENOTES PROPOSED ELEVATION NOIE: CONTRACTOR MUST VERiFY DRIVEWAY DESIGN. --- DENOTES ORAINAGE AND U111JTY EASEMENT ' DEN07E5 DRAINAGE iLOW DIRECTION NOIE: BEARINGS $HpWN ARE BASED ON AN ASSUMED DATUM -l?--- DENOTES SPINE - B DENOTES OFFSET HUB WE HEREBY CERTIFY TO AARBOR HOMES INC. THAT THIS IS A TRUE AND CORRECT REPRESENTATION OF A SURVEY OF THE BOUNDARIES OF: LOT 23, BLOCK 1, MURPHY FARM 3RD ADQITION MAR2 S REC'D OAKOTA COUNTY, MINNESOTA IT DOES NOT PURPORT TO SHOW IMPROVEMENTS OR ENCROACHMENTS, EXCEPT AS SHQWN, AS SURVEYED BY ME OR UNDER MY OIRECT SUPERVISION THIS 17TH DAY OF FEBRUARY, 2004. 31111Qa? nxip? SIGNED: ? 0 ENGINEERING, P.A. SCALE : 1 INCH = 30 FEET ; REVISEO 02-2j?-Q4 STAKED HOUSE BY? ?8? 100410005 SMD\TJW QC`FtS?' ?,1??(04ZrL7/4 Peter J. Hawkinson Reg. No. 42299 BENCH MARK _ -_- TOP OF SPlKE ELEV.- 12,6 2.7 ?4? y? - s.o 3 M ? « ? N 'a ' ? p ? 9 . p (n 1 4 0 PERMIT City of Eagan Permit Type:Building Permit Number:EA113777 Date Issued:09/09/2013 Permit Category:ePermit Site Address: 1630 Harbour Pt Lot:23 Block: 1 Addition: Murphy Farm 3rd PID:10-49502-01-230 Use: Description: Sub Type:Reroof Work Type:Replace Description: Census Code:434 - Zoning: Square Feet:0 Occupancy: Construction Type: Comments:If there is no ice protection inspection prior to final, the contractor must meet the inspector w/ a ladder and flat bar. Pictures are not acceptable in lieu of inspections. Carbon monoxide detectors are required by law in ALL single family homes . Vladislav Fogel Fee Summary:BL - Base Fee $4K $103.25 0801.4085 Surcharge - Based on Valuation $4K $2.00 9001.2195 $105.25 Total: I hereby acknowledge that I have read this application and state that the information is correct and agree to comply with all applicable State of Minnesota Statutes and City of Eagan Ordinances. Contractor:Owner:- Applicant - Lena Ginzburg 1630 Harbour Pt Eagan MN 55122 Estate Claim Services Llc 934 Cromwell Avenue, Suite 2 St Paul MN 55114 (651) 309-1114 Applicant/Permitee: Signature Issued By: Signature