Loading...
1166 Lexington Ridge Ct Date: 3/16/2006 Revision Date: 3/16/2006 Site IrMormation Address 1: 1166 LEXINGTON RIDGE Address 2: ? City: EAGAN MN County: DAKOTA Application Ir?formation Business Name: MILLERVILLE HOMES Contact Person: RAY MILLER Office Ph: 612-723-7137 Fax: 651-686-8098 Address 1: 1566 MURPHY PKWY City: EAGAN State: MN Zip Code: New Construction Project #: B-UNIT Lot: Block: Subdivision: MN Contractor License #: Cell Ph: House Details Square Feet: 4340 sq. ft. Avg. Ceiling Ht: 9 ft. Number of Bedrooms: 4 Ventilation : Balanced Total Ventilation Capacity : 171 cfm. Minimum Continuous Ventilation :75cfm. Intermittent Ventilation: 96 cFm. Combustion Appliance Water Heater: Power Vent Input BTUs: 75,000 Independently Vented Furnace/Boiler: Direct VenUSealed Combustion Input BTUs: 80,000 Independently Vented Other Combustion Appliances Gas Fired Direct Vent Fireplace(s): Yes Gas Fired Natural Draft Fireplace(s): No Exhaust Equipment Continuous Exhaust Ventilation Capacity (cfm): NA Exhaust Fan Rating (cfm): 350 Make-Ua Air No Make-Up Air Required by Code Gas Fired Power Vent Fireplace(s): No Solid Fuel Appliance(s): No Clothes Dryer (cfm): 135 Combustion Air Round Rigid Required: 5 inches or Insulated Flex: 6 inches Applicant Name (print):? l/LC??11L?F /NC ' Signature/Date: 1;'(4*S Z-7 Dlv Code Official (print): SignaturelDate: O )(1(ld ('?IprPn:ni FnPrm? ?R:nnPnacrn )llfld TTsv-hanir?l I`r..ln (L..UPIi..?c PwnP 1 Siteaddress: Lexi^161tY?) 1L; 14rk Lot 4? Block ? Subd.Z,eXj'w-k?sj gi?g On April 15, 2000 the Minnesota Energy Code, Category I Building Requirements for insulation protection, air tightness, and ventilation, was adopted. As a result, the City of Eagan is requiring that the following information be submitted prior to issuance of a Certificate of Occupancy. _ This structure; is constructed to meet minimum requirements of the Mn Energy Code, Chapter 7670 OR _ This structure: will be constructed to meet more restricfive requirements of Chapters 7672 or 7674 APPLIANCE GAS LEC MANUFACTURER MODEL BTU'S VENTINGTYPE Water Heater W?'4 .r?u"'&J [?j oco `? C 3 Fumace 3V AAV03Gp`dOAMk oLV Z' t'?/C Dryer -DFX u C's r nJ ZO " 51 to " EXHAU5T SYSTEM LOCATION TYPE MODEL CFM's VENTED YES No Kitchen kitchen I aU 350 Bathroom 1 .j v. 0lgq Q 3 ? O Bathroom 2 [ ? ( l $? ? Bathroom 3 Bathroom 4 Other FIREPLACE S LOCATION GAS WOOD MANUFAC RER MODEL BTU'S VENTING DIRe ATMOS yewft') &to s- ? gtk&,+ ke-oW ti t1 Glo D J / oo0 ? Lo,.w Le'e` ? f?a4' nJ G(p ?lE h 33 000 MAKE-UP AIR MODEL TYPE CFM's it- ko A%"/ v.e .,1 J4 : J P i l I hereby acknowledge that the above information is correct and agree to comply with the Minnesota Energy Code and City of Eagan xlov ,?jLC# 27/ ? Date ? ` This form is the responsibility of the General Coniractor. -T----- ' , jrVE ( I ? i ? + '-T- - ;??G•AW ??L __ : ' ? 8/p4? f , -- ? ? -- ? ? ? ' !3-L O? `?_-?` ' .?'Q?=L/?_ • ' - ---- '- ? ----- --- , _am i ' $ i tf?:--?-??-?- ? i -?-- t _4A?! ! ? ? ? i I ? i • __ ? i 1_?_! _.1-?-----=-'---? i- ? -----? -! ' --r-;-?? -- -- _ iU?T ? n I I ? - ' ` - ----T?'-- - ? - , '??---?--r i --- ? I ? r _T '_ -- -T--,---?-- t _ --,-- - ; , ? - ' ? ? ? !- ?- -- - -- , . 1 ? j r s. , I _ •? ? I y I ? . ? , , , . ( , ''• ? .--?----? ---c- -- -- I ` ? I' ! i' `?;•-e,',-.. !. . . I?`i I "T--' -------' ; ' ? ? i =- '; ?-------- -:- - ? '? ? ? t a p.dn, specjf;catio5 , "un3=a M7 ? visioa ? eseion?.1 E:)oe undea ih9 'f I- ? I 4u 1a wa ' , c? _. -„e _.:fcie s? s. sceeot?- ?--; -- ? ? - . I I ? ? _-- A---? !, ? L'ate 'L D?f, Rag.'PIo.I ? , ' ,- ? ? ; I I , ? ? ? I I I i , , , , ? ' i, I I ? I ? i ' ------' -'- -- . --------=-?---- r- -'- ; . , , - ------ -- - --- - - --- -- - ----, -- --- --- II I o frkI w (o--? '?-? ? (3 6?- `? 2*4 RESIDENTIA BUILDING PERMIT APPLICATIO?N City Of Eagan YYl ? • 3830 Pilot Knob Road, Eagan MN 55122 Telephone 4 651-675-5675 FAX # 651-675-5694 New Construdion Reomremenis 3 registered sile surveys showing sq R of lof, sq. fl. of house; and all roofed areas (20% mazimum lot coverage allowed) 2 copres of plan showing beam & window sizes; poured found desgn, efc. 1 set of Energy Cakulalions 3 copies of Tree Preservaiion Plan if lol platted afler 7l1193 Rim Jast Detail Op6ons selection sheet (bldgs with 3 or less units O L 3 ? -10,?3b\ RemodeVfteoair Reauiremenis &" Use40niv . 2copicsofplan Crs!'Gf8uroE1'Recd 1`N 1 set of Energy Cakulatiwns for hea(ed addilans Tt2e'Ptrs,PlmiRecd'_ isitesurveyforadcFitions&decks ?reC:pies;iiaz@iicEE[: ?.„,;YN Addifion-irrdMateifon-sitesepticsysfem S3a?siteSe"pt?5ysleitii?::::_Y:_N .., -AL- `7 <t-4-51 Date ? / ? / ? ? Site Address (?Ou L^-2-X.i?1G "- - • Constr?uction CosLt ?? 3? c ? ?-0 1 Unit/5te # Description of Work ? C-on Multi-Family Bldg -Yf?_ N Fireplace(s) _ 0 V 1 _ 2 Property Owner 1- \ll 1 kC??' ?^? ? ?v I C - Telephone # k I ? 7 ?-Zl ? 71 .Jj Contractor Addresa State M? CitY Zip Telephone # (&(-X -? COMPLETE THIS AREA ONLY IF CONSTRUCTING A NEW BUILDING Minnesota Rules 7670 Categorv 1 Mlnnesota Rules 7672 Energy Code Category , Residential Ventiiation Category 7 Worksheet • New Energy Code Worksheet (J submission type) Su6mitted Submitted . Energy Envelope Caleulations Submitted Have you previously constructed a building in Eagan with a similar plan? _ Y _ N If so, 25% plan review fee applies. Licensed Plumber ??1.1?1 9'IUYVU' d1 ?lCl Telephone #(qpu- y?a' ?U?N-o Mechanical Contractor Telephone #(9SZJ. 7H6-5ZOD Sewer/Water Contractor Ve1 W Telephone I hereby apply for a Residential Building Permit and acknowledge that the information is complete and accurate; that the work will be in conformance with the ordinances and codes of the City of Eagan and the State of MN Statutes; I understand this is not a permit, but only an application for a permit, and work is not to start without a permit; that the work will be in accordance with the approved plan in the case of work which requires a review and approval of plans. k?1 j ApplicanYs Print Name Applicant's Si ture OFFICE USE ONLY Sub Types ? 01 Foundation ? 07 05-plex ? 13 16-plex ? 20 Pool ? 02 SF Dwelling ? 08 06-plex ? 16 Fireplace ? 21 Porch (&sea.) A 03 01 of 2-plex ? 09 07-plex ? 17 Garage ? 22 PorchlAddn. (4sea.) ? 04 02-plex ? 10 OB-plex ? 18 Deck ? 23 Porch (screen/gazebo) ? OS 03-plex ? '11 10-plex ? 19 Lower Level ? 24 Storm Damage ? 06 04-plex ? 12 12-plex Plbg_Yor_ N ? 25 Miscellaneous Work Types A 31New ? 32 Add'Rion ? 33 Alteretion ? 34 Replacement Valuation 0 0?-v Census Code /d;_ SAC Units 4/ # of Units 0/ # of Bldgs ol Type of Const ? 35 Int Improvement ? 38 Demolish Interior ? 36 Move Building ? 42 Demolish Foundation ? 37 Demolish Building' ? 43 Reroof `Demolition (Entire Bldg) - Give PCA handout to applicant Occupancy R-3 MCES System Zoning 17 City Water Staries A Booster Pump Sq. Ft. A1J?5 PRV Length ? Fire Sprinklered Width ? r ? 30 Accessory 81dg ? 31 Ext. Alt - Multi ? 33 Ext. Alt - SF ? 36 Multi Misc ? 44 Siding ? 45 Fire Repair ? 46 WindowslDoors 1? ? ? Footings (new bldg) _ Footings (deck) FooUngs (addition) ? Foundarion Drain Tile Roof * Ice & Water _Z Final ? Framing ? Fireplace k R.I. _.*AirTes[ )? Final Insulation ? Approved By: Base Fee " ' Surcharge ' Plan Review P?ti9 MC/ES SAC City SAC Utility Connection Charge S&W Pertnit & Suroharge Treatment Plant License Search Copies Other ToWI REQUIRE INSPECTIONS FinaUC.O. FinallNo C.O. _ Plumbing _ HVAC Other _ Pool Ftgs Air/Gas Tests Final _ Siding _ Stucco _ Stone _ Brick _ Windows _ Retaining Wall Building Inspector h? w Permit Number REScheck Compliance Certificate 2000 Minnesota Energy Code REScheckSofhvare Version 3.6 Release 1 Data filename: B 1 otB 1-B 1.rck Checked By/Date i PRO fECT TITLE: Lexington Ridge: Units6 6' COUNTY: Dakota l!C 7-0a Xv? cT STATE: Minnesota ZONE: 2 CONSTRUCTION TYPE: Multifamily WINDOW / WALL RATIO: 0.13 DATE: 10/I9104 DATE OF PLANS: 10-14-04 ; DESIGNER/CONTRACTOR: Tim Fuller, AIA SALA Architec[s, Inc. COMPLIANCE: Passes Maximum UA = 931 Your Home UA = 598 35.8% Better Than Code (UA) ? Gross Glazing Area or Caviry Cont. or poor Perimeter R-Value R-Value II-Fac UA Ceiling 1: Raised or Energy Truss 1955 38.0 0.0 49 Skylight l: Wood Frame:Double Pane with Low-E 9 0.400 4 Walls - Upper: Wood Frame, 16" o.c. 3861 19.0 0.0 191 Window l: Above-Grade:Wood Frame:Double Pane with Low-E 426 0.340 145 Door 1 Glass 198 0320 63 Walls - Basement: Solid Concrete or Masonry:Interior Insulation 1042 0.0 11.0 74 Floor I: Slab-On-Grade:Unheated 78 5.0 58 Insulation depth: 3.5' Floor 2: All-Wood JoisUTruss:Over Uncondi[ioned Space 480 0.0 30.0 14 Furnace I: Forced Hot Air, 92 AFUE Air Conditioner l: Electric Central Air, 14 SEER Proposed and Maximum U-Factor Averages Proposed Maximum Average U-Factor Allowed U-Factor Above-Grade Windows and Glass Doors 0334 0.370 [ncludes Foundation Windows> Sb ft2 Skylights 0.400 0.000 Floors Over Unconditioned Space 0.029 0.033 COMPLIANCE STATEMENT: The proposed building design described here is wnsistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2000 Minnesota Energy Code requirements in REScheckVersion 3.6 Release 1(forttterly MECchecj? and to comply with the mandato .ry requirements Iisted in the RES checklnspection Checklist. Builder/Designer ac??`. X!(.L. ) Date loI ?ow 0 1 LOT SURVEY CHECKLIST FOR RESIDENTIAL ` BUILDING PERMIT APPLICATION PROPERTY LEGAL: I3lCr?K ) {'Q.7(_ i DATE OF SURVEY: LATEST REVISION: m a c m t U 0 2 Q DOCUMENT STANDARDS f? ? 0 . Registered Land Surveyor signature and company ? ? • Building Permit Applicant .? 0 ? • Legal description ? ? ? • Address ? ? ? • North arrow and scale ? ? • House type (rambler, walkout, split w/o, split entry, lookout, etc.) ? 0 ? . Directional drainage arcows with slope/gredient % 1?' ? 0 . Proposed/existing sewer and water services & invert elevation .W ? ? • Street name .H ? 0 . Driveway (grade & width - in RIW and back of curb, 22' max.) Xf ? ? • Lot Sguare Footage Z ? 0 . Lot Coverage ELEVATIONS Ew'stina ,¢I ? ? • Sewer service (or Proposed) ? ,g ? • Property comers ,H ? ? • Top of curb aT the driveway and property Iine eMensions ? ? • Elevations of any existing adjacent homes ? ? • Adequate footing depth of sVUCtures due to adjacent utility trenches ? g ? • Waterways (pond, stream, etc.) Prooosed .9 ? 0 • Garage floor z ? ? • Basement floor 'z ? ? • Lowest exposed elevation (walkouUwindow) D .? ? • Property comers A ? ? • Front and rear of home at [he foundation PONDING AREA (if aoplicable) ? ?f ? • Easement line ? ?B ? • NWL ? ? • HWL O ? ? . Pond # designation o ? 0 • Emergency Overflow Elevation ? fd ? • Pond/VJeUand buffer delineation DIMENSIONS ? ? ? • Lot lines/Bearings & dimensions .e( ? ? • Rightof-way and street width (to back of curb) ? ? ? • Proposed home dimensions including any proposed decks overhangs greater than 2' porches etc , , , . (i.e. all structures requiring permanent footlngs) ? ? ? • Show all easements of recorcl and a City utilities within those easements ,H ? ? • Setbacks of proposed structure a s eyard setback of adjacent existing structures ' ?B ? ? • Reta(ning wall requirements, if Reviewed: me ate G:/FORMSIBuilding Pertnit Application Rev. 12-16-03 . • Surveyor's Certificate SURVEY FOR : Millerville Homes DESCRIBED AS : Lot s&s, BIocXINGTON RIDGE, City of Eagan Dakota County, esota and reserving eosements af record. ? 3:9 Mattimum Slopes or -, .-:,1 l,ng Wall dUill Ba tieyuired -?d ? ?--------, ` i ? sso. OH1? i i I \-- ? 1 _4 N89'40'54"E 88.00 A 0 0 B o.ck o, .oo . o, o.cxE 7.33 0 0 6 6 F 0.0 o 0 ? ? m N 3 1-4 LOT 4 ? 0 ? ? ? ? (1) O O ? Proposed ? Tob=991.0 O frl J ?.17 0 Lo-0 flM7QLL MROS9OM -- a Mff OR D S' S . SEM'ER o ? 990. -L.P._ . N n " OIP WAlERMAIN Droino9e ond UtllitY Easement/ ? Propoaed d Townhomas ? 9'Pcw w/o R1 A J ? ? 91111 1 1 Garage Propoaed Townhomea 9'pcw w/o 1166 Garaga u .Oi 97.50 v +ra0 RIDGE I L -------------- LOT SQ. FOOTAGE HSE SQ. FOOTAGE LOT COVERAGE _ PROPOSED ELEVATIONS ? .• c Top of Foundation = 991.3 Garage Floor = 990.9 = Basement Floor = 982.3 • u Aprox. Sewer Service = 977.3=5/977.5=6 Proposed Elev. - 0 Existing Elev. _ Drainage Directions = Denotes Offset Stake = • HEDLUND PJ.ANNlNG !lNGINa'ERING SURV6YIN0 2005 Pin Oak Driva Eagan, MN 55122 Phone: (651) 405-6600 Fox: (651) 405-6606 = 6,864 = 4,280 62% ME`YN?WE? '?. 143T6 SCALE: 1 inch = 30 feet 0 (',NS PL,!. MIN. SETBACK REQUIREMENTS Front - House Side - Rear - Garoge Side- I HEREBY CERTIFY THAT THIS IS A TRUE AND CORRECT REPRESENTA710N OF 7HE BOUNDARIES OF THE ABOVE DESCRIBED PROPERN AS SURVEYED BY ME OR UNDER MY DIRECT SUPERVISION AND DOES NOT PURPORT TO SHOW IMPROVEMENTS OR ENCROACHMENTS, EXCEPT AS SHOWN. DAlE J-/2a09?t in. ' F D. LIND6REN, LAN URVEYOR MINNESOTA LICENSE NUMBER 14376 N0: 04R-591 BOOK: Lex-Ridge mm 7a r 7 1 2oos RESIDENTIAL PLUMBING PeRMir aPPUCAnoN CITY OF EAGAN 3830 PILOT KNOB ROAD, EAGAN MN 55122 651-675-5675 Please complete for modfications to existlng residenHal dwallings. So.Sd te / I 0? / ,:7300(o D ` ? a ?? ??nit a Site Street Address ? ? ? E' 1l ? 1Pv VM-e Tn `l, Telephone #((p? )al?-? Property Owner ? ? 6U QI? ?l ?? ?xy??? ? G? I?r t, Telephone # qw ? Contractor Address =? \1S I ?' 0 n c?c,? J o rd cu'? State n i• 1 N Zip553 The Applicant Is: _ Owner '?Z Contractor _Other Septic System _ New _ Refurbished Submit 2 sets of plans and MPC license fee Indudes County S 100.00 Per as-built $ 10.00 \ Alterations to existing dwelling _ Add piumbing fixtures. This fee indudes installation of a water softener and/or water , a . V ter heater at the same time. If you are installing on a water saftener and/or w ? dc\the heater, do not complete this section; move lo the next secfion and che appiiance(s) you are installing. _Septic System Abandonment Water Tumaround (add $13,Q 00 ff a 5/8" meter is re?re????) i? -?1.?1?'l ' otner. ?t r1 i 5k I7,f ??? gY) , Water Softaner _ Water Heater $ 15•00 _ new _ replacement Lawn Irrigation _RPZ _PVB _new _repair _rebulid $ 30.00 State Suroharge $ .50 $50, 5Q Total I hereby apply far a Residential Piumbing Permit and acknowiedge that the infwmation s complete arxl accurate, that the work will be in conformance with the ordinances and codes of the City ot Eagan and the plumbing codes; that f undersfand this is not a permit, lwt only an application for a permit, wro k is rrot to staA wi[hout a permit and work wdl be in a rdance with the approved plan in the event a plan is required o reviewed an ap ved. AppiicanYs Print d Name ApplipnYs Sign re .? . AUTOMATED BUILDING COMPONENTS, INC. COMPONENTPLANT June 21, 2005 Lexington Ridge Townhomes Millerville Attn: Aazon Topp 1166 Lexington Ridge Eagan, MN I have inspected the floor kusses in this unit and find them to meet the required specifications. L" s&JF Chuck Schultz Sales Rep. Automated Building Components P.O.BOX7 • MONTROSE, MINNESOTA 55363 •TEL.763-675-7376 2006 RESIDENTIAL BUILDING PERMIT APPLICATION City Of Eagan 3830 Pilot Knob Road, Eagan MN 55122 Telephoue # 651-675-5675 FAX # 651-675-5694 New Construchon Reauirements 3 registered sfle surveys showing sq. fl. of lot, sq. tt. of house; and all roofed areas (20%maximum lot coverage allowed) 2 copies of plan showing beam 8 window sizes, poured fountl design, etc. 1 set of Energy Calculations 3 copies of Tree Preservation Plan if lol plafled after 711193 Rim Joist DeWil Oplions seleclion sheet (buildirgs with 3 arless unils) Minnegasco mechanical ventila[ion form Remode6Reoair Reouiremenis 2 copies oi plan sMwing foolings, beams, joisls 1 set of Energy Calculations forheated additions i site survey for addiGons & decks Adddion - indkafe ilon-sde sepfic sysfem 4-7U. ??° office use onro CeA of Survey Recd _ Y. _ N Tree Pres Plan Recd _ Y_ N. Tree Pres Required Y _N On-sdeSeplicSystem _Y _N Date l 117__ 1zo& Site Address 1166, 1 2x'n16-7+J /(r p&C- Construction Cost 154 D d v UniUSte # 5 Description of Work Multi-Family Bldg _ Y -/lV Fireplace(s) _ 0 2 PropertyOwner //???2cd(1-E ?.?K Telephoneii(%1/Z ) 3SY'?'fG`f J////Le-C?LC!lCLF Contractor ? Address 15?& A-(01cpN4 !'ic? State //?l? ' City C"46 "1 ? Zip ,SS / 2 Z- Telephone # (Z, /Z ) TZ-?' - 71 ? 7 COMPLETE THIS AREA ONLY IF CONSTRUCTING A NEW BUILDING I _ q -, .. ' I Minnesota Rules 7672 Energy Code Category - Minnesota Rules 7670 Cateeoiv' i . Residenlial Ventilation Category t Worksheet ' • New Energy Code Worksheet (4 submission type) Submitted Submitted . Energy Envelope Calculatiorbfitted , In the lasl 12 months, has the City of Eagan issued a permil for a similar plan based on a master plan? _ Y _ N If yes, date and address of master plan: Licensed Plumber Mechanical Contractor Sewer/Water Contractor Telephone # ( Telephone #( 7elephone #( I hereby apply for a Residential Building Permit and acknowledge that the information is complete and accurate; that the work will be in conformance with the ordinances and codes of the City of Eagan and the State of MN Statutes; I understand this is not a permit, but only an application for a permit, and work is not to start without a permit that the work will be in accordance with the approved plan in the case of work which requires a review and approval of plans. AppIT icanYs Printed Name Applic ' ignature DO NOT WRITE BELOW THIS LINE Sub Tvpes ? 01 Foundation ? 07 OS-plex O 13 16-plex ? 20 Pool ? 30 Accessory Bldg ? 02 SF Dwelling ? 08 06-plex ? 16 Fireplace ? 21 Porch (3-sea.) ? 31 Ext. Alt - Multi O 03 0 7 of _ plex ? 09 07-plex ? 17 Garage ? 22 Porch/Addn. (4-sea.) ? 33 Ext. Alt - SF ? 04 02-plex ? 10 08-plex ? 18 Deck ? 23 Porch (screen/gazebo) ? 36 Multi Misc. ? 05 03-plex ? 11 10-plex ? 19 Lower Level ? 24 Storm Damage ? 06 04-plex ? 12 12-plex ? 25 Miscellaneous Work Tvqes ? 31 New ? 35 Int Improvement ? 38 Demolish Interior ? 44 Siding ? 32 Addition ? 36 Move Building ? 42 Demolish Foundation ? 45 Fire Repair )c 33 Alteration ? 37 Demolish Building' ? 43 Reroof ? 46 WindowslDoors ? 34 Replacement •Demolition (Entire Bidg) - G ive PCA handout to applicant _ DBSCrIDt1011: Water Damage _ Yes Valuation o(" Occupancy MCES System Plan Review _ 100% or _ 25% Census Code Zoning Ciry Water SAC Units Stories Booster Pump # af Units Sq. Ft. PRV # of Bldgs Length Fire Sprinklered Type of Const Width _ Footings (new bldg) _ Footings (deck) _ Footings (addition) Foundation Drain Tile Roof Ice & Water Final x Framing Fireplace ? R.I. 4Air Test ? Final ? Insulation Approved By: Base Fee Surcharge Plan Review MC/ES SAC City SAC Utility Connection Charge S&W Permit & Surcharge Treatment Plant License Search Copies Other Totai REQUIRED INSPECTIONS _ Sheetrock FinaVC.O. ? Final/No C.O. ? HVAC Other _ Pool Ftgs Air/Gas Tests Fiual _ Siding _ Swcco Lath _ Stone Lath _Brick _ Windows _ Retaining Wall Building Inspector ? rr,?? S61, ?, Q r?v ? Address: 1166 Lexington Ridge Ct Zip: 55121 Lot: 5 Block: 1 Subdivision: Lexington Ridge THE FOI,LOWIN(:ITCMti R'ERA%WERF. NOT COMPLL'PE AT FI\AL INSPH(TIOV ON Yes No Comments Final grade - 6" from siding kll Permanent ste s- ara e Permanent ste s- main ent Permanent drivewa Permanent as Retainin Wall or 3:1 Max Slope SodlSeeded lawn Trail/curb dama e Porch Lower level finish Deck Fireplace v • Verify with your builder tktat roof test caps from the plumbing system have becn removed. • Turn off water supply to the outside lawn faucets before Geeze potential exists. • Call ihe Ci;y's Engincaring Departmer.t at 651-675-560.6 p:ior to svorking in nght-of-ivay or installing irrigation system. J BUILDING INSPECfOR ? CONTRACTOR: Millerville 1566 Murphy Parkway Engan vIN 55122 ct, l?? ?-l°l f3P-c??c?3-7 4R?'.? (C20 NTIAL BUILDING PERMIT APPLICATION City Of Eagan M ? ? - 3830 Pilot Knob Road, Eagan MN 55122 Telephone # 651-675-5675 FAX # 651-675-5694 S? 3(? .14 New Conslmc6on Reauirements RemodeVRmair Reauiremenis ?fl? ?1?? ?SeOrdv 3 registered sile surveys showmg sq. ft of IM, sq fl. of house, and gll roofed areas 2 copies of plan (20% mazimum lot coverage allwio 1 sel of Energy Cakulations for healed addhons Tree P?¢s"P19A {tecd? :. "".;:.::Y' ._ N 2 copies of plan shawng beam 6 window sizes; poured found design, elc . t site survey for adddwns & decks isetofEnergyCalculafwns Add'?tion-ind?cateilon-sdasepfresystem 01?§i105Epti??ySYeifi'.. N 3 copies of Tree Preservation Pian if lot plailed afler 7l1?3 l I Rim Joist Delail Opiwns selecfion sheet (bldgs wilh 3 or less units -1 Z Y c Date Coptruction Cost A J.Jq co0 Site Addreas ? ? b? L ?-\ ?lG tx? U UniUSte # Description of Work Ing-(A, C.Of-)?? ?V` Mulri-Family Bldg ? Y _ N Fireplace(s) _ 0 ? 1 _ 2 O Telephone #(?Q wner Property Contractor Address 15 r?-v? CiTy State Zip Telephone # COMPLETE THI AREA ONLY IF CONSTRUCTING A NEW BUILDING Minnesota Rules 7670 Cateeorv 1 Mumesota Rules 7672 Energy Code Category , Residential Ventilation Category t Worksheet • New Energy Cade Worksheet (J submission type) Submitted Submitted • Energy Envelope Calculations Submitted Have you previously constructed a building in Eagan with a similar plan? ZY_ N If so, 25% plan review fee applies. Licensed Plumber Bw °Im:?r) Telephone #( Mechanical Contractor 1 ('?-^ Telephone Sewer/WaterContractor VZ-l e- Telephone I hereby apply for a Residential Building Permit and acknowledge that the information is complete and accurate; that the work will be in conformance with the ordinances and codes of the City of Eagan and the State of NIN Statutes; I understand this is not a permit, but only an application for a permit, and work is not to start without a permit; that the work will be in accordance with the approved plan in the case of work which requires a review and approval of plans. &?, L. Applicant's Prin d Name Applicant's Sigi ture OFFICE USE ONLY Sub Types i ? 01 Foundation ? 07 05-plex ? 13 16-plex 0 20 Pool ? 30 Accessory Bldg ? 02 SF Dwelling ? OB 06-plex ? 16 Firepiace ? 21 Porch (3-sea.) ? 31 Ext. Alt- Multi ;1 d- 03 01 of04plex ? 09 07-plex ? 17 Garage ? 22 Porch/Addn. (4-sea.) ? 33 Ext. Alt - SF ? 04 02-plex ? 10 08-plex ? 18 Deck ? 23 Porch (screen/gazebo) ? 36 Multi Misc. ? 05 03-plex ? 11 10-pleac ? 19 l.ower Level ? 24 Storm Damage ? 06 04-plex ? 72 12-plex pibg_vor_nl ? 25 Miscellaneous Work Types X 31 New ? 35 Int Improvement ? 38 Demolish Interior ? 44 Siding ? 32 Addition ? 36 Move Building ? 42 Demolish Foundation ? 45 Fire Repair ? 33 Alteration ? 37 Demolish Building' ? 43 Reroof ? 46 Windows/Doors ? 34 Replacement •Demolition (Entire Bldg) - Give PCA handout to applicant Valuation /,?5-ay Occupancy /1` -3 MCES System Census Code O;_ Zoning RD City Water ? SAC Units 0l Stories Booster Pump # of Units a/ Sq. Ft. ? 37L PRV # of Bldgs ? Length ? Fire Sprinklered ? Type of Const Width ? Footings (new bldg) _ Footings (deck) Footings(addition) ? Foundation Drain Tile Roof -AL Ice& Water 4 Final Framuig Fireplace ,t- R.I. k-AirTest ' Final Insulation ? Approved By: _ v Base Fee Surcharge Plan Review MC/ES SAC A,7 °,fe City SAC Utility Connection Charge S&W Permit $ Surcharge Treatment Piant License Search Copies Other Total REQUIItED INSPECTIONS ? FinallC.O. FinaUNo C.O. _ Plutnbing _ HVAC Other _ Pool Ftgs _ Air/Gas Tests Final _ Siding _ Stucco _ Stone _ Brick _ Windows _ Retaining Wall Building Inspector , r Permit Number REScheck Compliance Certificate Checked By/Date 2000 Minnesota Energy Code REScheckSoftware Version 3.6 Release 1 Data filename: C:\Documents and Settings\bmurphy\Desktop\Energy Calc_I0-14-04 Ptans\3_4_1I_12.rck PROJECT TITLE: Lexington Ridge Units: 3, 4, 11, 12 COUNTY: Dakota STATE: Minnesota ZONE: 2 CONSTRUCTION TYPE: Multifamily WINDOW / WALL RATIO: 0.16 DATE: 10/19/04 DATE OF PLANS: 10-14-04 DE SIGNER/CON TRACTOR: Tim Fuller, AIA SALA Architects, Inc. COMPLIANCE: Passes Maximum UA = 795 Your Home UA = 552 30.6% Better Than Code (UA) ' Gross Glazing Area or Cavity Cont. or poor Perimeter R-Valu R-Value -Fact r LiA Ceiling 1: Raised or Energy Truss 1587 38.0 0.0 40 Ceiling 2: Cathedral Ceiling (no attic) 393 38.0 0.0 11 Walls - Upper: Wood Frame, 16" o.c. 3534 19.0 OA 168 Window I: Above-Grade: Wood Frame:Double Pane with Low-E 487 0340 166 Door 1: Glass 193 0.320 62 Walls - Basement Solid Concrete or Masonry:lnterior Insulation 644 0.0 11.0 46 Floor 2: Slab-On-Grade:Unheated 80 5.0 59 Insulation depth: 3.5' Fumace 1: Forced Hot Air, 92 AFUE Air Conditioner 1: Electric Central Air, 14 SEER Proposed and Maximum U-Factor Averages Proposed Maximum Average U- Factor Allowed U-Factor Above-Grade Windows and Glass Doors 0334 0.370 Includes Foundation Windows > 5.6 112 COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specitications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2000 Minnesota Energy Code requiremenu in REScheckVersion 3.6 Release 1(formerly MECchec'? and to comply with the mandatory, equirements listed in the RES checklnspection Checklist. Builder/Designer ?1?Z?' Date Lfq4t ? V . Surveyor's Certificate SURVEY FOR : Millerville Homes DESCRIBED AS : Loc 11&12, Block 1, LEXINGTON RIDGE, City of Eo9an __----Zkpto County, Minnesota and reserving eosements of record. \ - _ Droina e ond Ut(lit Easement II -__--___- 1?w /?4? - ?=m11- ? COURT-? ?,,,,, A 8" SAN. SE'MER ??aonn?? vr[ ?• "M 2 o.sq --? ' 6 DIP WA - _-_ - --__ ?3 ?v4v . -?__---- I o _ __--_ ?77. 0l 22.00 22.00 ?11 ? 26.9 ? m I ? u Carage u o 990. w Garoge u I Proposed HYDR? ?1 I 01169 o 990.7 g »ss o i I iob=992.5 O O 0 ? 9 00.`? 9.00 1.50- . 3 J . p o 9.5 7 50 0 0 9.50 7 50 $ o u {>0 . . 1.50 ? . 0 ? 1.50 LOT 10 01 I ? I 2-Story Z-StOfy m I N m 9'pcw w/o ' I Townhomes pcw w/o 9 ? ? ? Proposed Townhomes Proposed 1 ? O ? 14.00 p 11 12 j 14.00 ? O ? 9 Dsck J 76.4$ A A 16.45 J Oeck ? 1 .- I 81am_ ?i.,?- 0 17.54 r 17.54 ° F?s -'?00.8 1 ? S89'40'54"W 106.00 ? EWE D .? By Date /0/7 04INSTALL EAGAN ENGINEERING DEP1: SILT FENCE LOT SQ. FOOTAGE = 8,268 HSE SQ. FOOTAGE = 5,069 LOT COVERAGE = 61 % PROPOSED ELEVATIONS Top of Foundation = 991.3 Garage Floor = 990.9 Basement Floor = 982.3 Aprox. Sewer Service = 977.3=11 /977.5=12 Proposed Elev. _ <Z--::> Existing Elev. Orainage Directions D t Off t 5t k LOT l3 Proposed Tob=993.3 M A? ? ? ? ?? z cn "O rmn A, ?? BENCHMARK : r : SURVc pR : nt i . t aS 1 : f ?9i.'•. 437$ .tie..? eno es Se 0 e- - SCALE: 1 Inch = 30 feet HEDLUND PLINMNG 6NGINEBRING SURVBYlNC 2005 Pln Oak DrIve Eagan, MN 55122 Phone: (651) 405-6600 Faz: (651) 405-6606 r' - s? P"11 , ? MIN. SETBACK REOUIREMENTS Front - House Side - Rear - Garoge Side- JOB NO: I HEREBY CERTFY TriAT THIS IS A ii2VE AND CORRECT REPRESENTATION 04R-593 OF THE BOUNDARIES OF THE ABOVE DESCRIBED PROPERTY AS SURVEYED 8Y ME OR UNDER MY DIRECT SUPER41510N AND DOES NOT PURPORT TO BOOK: PAGE: SHOW IMPROVEMENTS OR ENCROACHMENTS, EXCEPT AS SHOWN. DA7E _1`_/?/SLS O' CAD FILE: F D. LI GREN, LA SURVEYOR MINNESOTA LICENSE NUM R 74376 Lex-Ridge Date: 5/9/2005 Revision Date: 5/9/2005 Site Information Address 1: '1"169 LEXINGTON RIDGE Address 2: City: EAGAN County: Application Information Business Name: MILLERVILLE Contact Person: RAY MILLER Office Ph: 612-723-7137 Fax: Cell Ph: Address 1: 1566 MURPHY PKWY City: EAGAN State: MN Zip Code: 55122 New Construction Project #: TOWNHOMES Lot: Block: Subdivision: MN Contractor License #: House Details Square Feet: 2806 sq. ft. Avg. Ceiling Ht: 9 ft. Number of Bedrooms: 4 Ventilation : Balanced Total Ventilation Capacity : 110 cfm. Minimum Continuous Ventilation :75cfm. Interrnittent Ventilation: 35 cFm. Combustion Appiiance Water Heater: Power Vent Input BTUs: 50,000 Independently Vented Fumace/Boiler: Direct VenUSealed Combustion Input BTUs: 80,000 Independently Vented Other Combustion Aapliances Gas Fired Direct Vent Fireplace(s): Yes Gas Fired Power Vent Fireplace(s): No Gas Fired Natural Draft Fireplace(s): No Solid Fuel Appliance(s): No Exhaust Equipment Continuous Exhaust Ventilation Capacity (cfm): NA Clothes Dryer (cfm): 135 Exhaust Fan Rating (cfm): 500 Make-Ua Air Total Make-Up Air Required (cfm): 114 Passive Make-Up, Round Rigid: 6 inches or Insulated Flex: 7 inches Combustion Air Round Rigid Required: 4 inches or Insulated Fiex: 5 inches Applicant Name (print): /vliLt-&?J Ilcf 44C, Signature/Date: Code Official (print): Signature/Date: n innd )nnn nnP?hA.,;,.9i r.waP va?P i Siteaddress: (a Lot // Block ? Subd. r? --? .11 ? vi?? C4 .. On April 15, 2000 the Minnesota Energy Code, Category I Building Requirements for insulation protection, air tightness, and ventilation, was adopted. As a result, the City of Eagan is requiring that the following information be submitted prior to issuance of a Certificate of Occupancy. This structure: is constructed to meet minimum requirements of the Mn Energy Code, Chapler 7670 OR This structure: will be constructed to meet more restrictive requirements of Chapters 7672 or 7674 APPLIANCE GAS ELEC MANUFACTURER MODEL BTU'S VENTINGTYPE waterHeater B??, 0OI11 3it PvC Fumace ?J(L ar?.. ?`fpMA.?Oz?fo?f0 (e0 10D I? ?L Dryer ? L-r- CL£G K..il G 7-52Z IJ S Ni x EXHAU5T SYSTEM LOCATION TYPE MODEL CFM's VENTED YES NO Kitchen kitchen I IYF l/ 5 u Zc?s 5av Y Bathroom 1 ?J ?ro?n p ?Q Bathroom 2 c,,? ? 5- 0 V? g p Bathroom 3 ru u r ?lU U A r Bathroom 4 6f- 0 ei N r 's Other P FIREPLACE S LOCATION GAS WDOD MANUFACTURER MODEL 8TU'S VENTING DIRECi ATMOS /LCAy QaDn, L"? T rl l.0 li 000 T121 "II i --b 000 MAKE•UP AIR MODEL TYPE CFM's tzemylj ; r-I ? o 0-V /?8-- I hereby acknowledge that ihe above mformation is correct and requirements. 1 4?/ ignat,h' /-?/iL r tt2JI uT_ CompanyName agree to comply wifh the Minnesota Energy Code and City of Eagan A I f ? v o Date ' This form is the responsibility of the General Coniractor. Mar 18 OS 06:05p Jerry Palms 6123783736 p.2 P,SAe1ji7'# 6?637 STRUCTURES ?erry Palms P.E. Slructural Enginecr 416 Hennepin Avenuc East Minneapolis MN 55474 612 / 378 0393 (Voice) 6121378 3736 (Fax) - - .hu<9o,ireunoLcum MEMC7RANDUM #6 LEXINGTON RIDGE TOWNHOMES DIFFLEY ROAD AT LfXINGTON WAY EncnN MN SALA #04070 i- iSTRUCTURES #0408-2 Mazch 18, 2005 Jeff Wheeler Building Inspections Cify of Eagan MN Deaz Jeff: At the request of Ray Miller, I have reviewed the following structural conditions which you observed during a recent site visit at the above referenced project. There are also a couple of additional concerns which will be addressed when the contractor and I have an opportunity to mect on the si#e ihe week aRer next. I44 b.0W ?,pYeva? r2fp? G7? It is my understanding that all of these concerns are related to Unit 11, hich is currently under construction. However, if similar conditions should arise later in the project, they may also be addressed in the same way: Item #1: Steel oost bearine on nad footinQ: The contractor has selected a steel post with an adjustabie screw jack. The sc:rew jack has been positioned at the bottom end of the post. You have observed that the contractor's installation of the post vazies in two respects from what I specified in thc structural notes: a.) Whereas I called for '/z" or so of grout under tlae post bearing plate, the post was installed without grout. Evaluxtion: Although grout helps to distribute the load &om the post evenly over the conerete footing, I can nevertheless approve of this installation in this case. b.) Whereas I called for an anchor bolt connection between post and footing, the contractor's method of installation wi11 serve the same pwpose just as well. Mar 18 OS 06:05p Jerry Palms 6123783736 p.3 <,STRUCTURES Jerry Paims P.E. S(rucwral Enginecf 416 Hennepin Avenue East Minneapolis MN 55474 612 l 378 0353 (Voicc) 612 1378 379G (Fax) 1e1 yPe 11, u<Uni nel Evaluation: My purpose was to assure titat tlie post cannot move. Once the coiatractor pours the floor slaU around the post, the post will be locked in place, and the same purpose will be accomplished. x * x x m Item #2: Steel beams bearina at end walls: T'he contractor has indicated that in two cases a steel beam bcars only 1% inches on the wall. In one case, the wall is wood stud constructioa In the other case, it is a concrete wall. Evaluation: Where a steel beam beazs on a wood waD, the contractor will fur out the wall with a treated 2x6, nailed continuously to the existing wood post in the wa11. The 2x6 should be installed very snug. This will provide a minimal, but adequate, 3" of bearing for the steel lxam. Where a steel beam beazs on a concrete wall, the contractor will add a 4x4 parallam post under the steel beam. If the parallam is not treated, iY must bear on treated wood in order to isolate it from any concrete. Again, the post should be installed as snug as possible. ? r x * Item 43: Window he?adcr at uuoer floor: At the upper roof framing plan for Plan "A", I calied for a(2)2x10 header at one of the end windows. A(3)2x8 header will a(so be adequate. Sincerely, Jerry Palms PE Structural En-ineer tiTRUc, TUREti I hereby certify that this pian, specifica- tion or report was prepared 6y me or under my direct supervision and that I am a duiy gisrered prof i al engineer under th I of the st in ewta. ? ?b1N 'e4 3 arch 18, 2W5 Mnecn 18, 2005 / PnGe 2 MPy-12-2005(THU) 10:37 517 Flcst Sfreet Fartnington, MN 55024 (651)4639333 (651 )t83-9339 - Fau =mr;WA ._y To: Je}F Fron! Fa= 651-6754694 p+8es; 1 pywe: naec: 512-05 wx Spray toam Info cC. ? Lrgont E3 For Rw»w 0 Ptsase Conunsnt 17 Plcasc RoWY G Plaaso RecyGs 9 Commcntx We used(class one spray foam In the rlm Joist atea at Lwdngton Rldga -?_ __ - .... .. P.0011001 The toam vras kiuraseai foam ?-_ (G6 3? 69 G.Bx l!„6 c7 . .? ¦ AUTOMATED BUILDING COMPONENTS, INC. COMPONENTPLANT May 9, 2005 L,exing[on Ridge Townhomes Millerville Attn: Aazon Topp Unit A, Lot Iff, I/ 1169 I,exington Ridge Eagan, MN I haue inspected the floor trusses in this unit and find them to meet the required specifications. l:_7w" Chuck Schultz Sales Rep. Automated Building Components P.O. BOX 7 • MONTROSE, MINNESOTA 55363 • TEL. 763-675-7376 flpr 06 05 09:I5p Jerry Palms 6123783736 p.2 ARCHISTRUCTURES leny Palms P.E. 5lrucwral Enginreer 416 Hennepin Avenwe East Minneapolis MN 55414 672 1378 0391 (Voice) 672 / 378 3736 fFaa) m hiqlucUU"iAaol uwu April 6, 2005 Jeff VJheeler Building Inspections City of Eagan MN Deaz Jeff: MEMORANDUM #7 LE%INGTON RIDGE TOWNlfOMES DIFFLEY ROAO AT LFXINGTON WAV EncnN MN SALA 1f0407o ARCHISTRUCTURES #0408-2 At the request of Ray Miller, I have reviewed the following structural conditions which you observed during a recent site visit at the above referenced project. Again, thank you for alerting me to these coneerns, especially Item #5 below. Please also refer to Memorandum #6, dated Mazch 18, 2005, in which I previously addressed tlvee ofyour concerns, which I have listed as [tems #I, #2 and #3. I visited the site on Thursday to make observations reiated to two additional concerns, which are listed in the following as Items #4 and #5. h is my understanding that all of these wncems are related to the unit under construction at 1169 Lexington Ridge Cour[. However, if similaz conditions should azise elsewhere on the project, they may also be addressed in a similar way. Item #4: Vertical crack in t6e concrete basement foundation wall: The vertical crack extends almost full height of the north wa1L [t is a micro-crack which appears to have formed shortly after the wall was poured, while the concrete was still curing. Evaluation: Assuming that [he #4 @ 2'-0" hoc specified, the cracks would not have been cau; veRical crack forms while the concrete is sti accidentally kriocked during the backfill process. and discussion with the contcactor, I was not a61 the cause. wntal steel reinforcing was placed as ed 6y shrinkage. Most often, when a I curing, it is 6ecause the wall was However, based upon my observations ? to make a defmitive determination of In any case, the crack does not compromise the s[ructural capacity of the wall. No repair is required. Hpr 06 05 09:17p Jerry Palms 6123783736 p.3 ARCHISTRUCTURES lerry Palms P.E. StrucWral Enginecr 416 Hennepin Avenue East Minneapolis MN 55414 612 / 778 0393 IVoicc) 612 / 378 7736 (Fax) jenYiv.u, L.qmclwra nNl the top of the noRh foundation wall is unbraced by any against the wall could cause it to move forward. +alls• I observed that so that sofl pressure Evaluation_ As a general performance standazd, it is essential that the top of the concrete foundation wall be effectively braced against possible inward movement t}ut could be caused by exterior soil pressure. In this case, floor trusses run parallel to the north wa11, so that some system of blocking must be installed petpendicular to the trusses. Norrmlly, this blocking would be installed at 24" on center, similaz to the spacing of the tnuses. It is essentiat that t6e blocking be effective in bracing the top of the concrete wall by transferring any load from the top of the wall into the plywood diaphragm of the floor. In fhe present case, the noRh wall is comprised of relatively short lengths interrupted by jogs in the walk. As noted in the code, such a wall of uregulaz construction is at least partially self-bracing. However, it is not prudent to ignore the bracing entirely, since a wall failure wou(d be cosdy to repair. Recommendation: Please refer to the attached Detai] Sheet D4, where I have provided a sample bracing solution. I know that the contractor must make room for ductwork, so that if this solution does not work in every case, the contractor is responsible to provide alternate bracing of equal or better capacity according to the above performance standard. I may be contacted for additional assistance. Sincerely, Jerry Palms PE Structural Engineer ARCHISTRUCTUR[ti Copy to: Ray Miller / Millerville Inc I hereby certi(y that this plan, specifica- lion or report was prepared by me or under my direct supervision and that I am a duly registered prokssiogaI engineer under the?laws 9f the st?9Minnesota. MN RcIA J#9033 tl April G, 3005 APRIL 6, 2005 / PAGE 2 L9xIN & raH RJ OGE 6q 0 11,49,r_ ;' 0?3 G_C14/NGTON K/OG E -- S? / E? A fr ? MN- sur ??aon ? ?,?-? GaRAGw F[oaR ?- ? a64Q JotsT ? - -.? ?• ?/ \ j. \ I 4- /o /'ENNy b I p?WHERE Tf4E G?4RAG? N/]/ts ? E4 X.C3kA CING US/?G ,VE Wf}L.L ISlO X ENO.(fY?"? 2?'f3 L' G?O`U.C I r/ oN1-y i? r,s<E otllsioE- v?L a,2Rc. wc. QE ,eG 9v. W/F G-G S G/tNS /? c/k' Ffl?iE? TH etoe! 8'- e" /lORt Z, 4,VD ?- TNE /•=/LL i76-RfA?7Y%te yu/}LL /S flr11z`/th!"i79f 9'. . hezeby certify thai this plan, sp_cificatiou, ir xeport was pxopaxed by me ot undei mq 3iiect supe:vision and that I am a dulp 8egistered Professional Engineex undex the tawa of the Staie oi Minneso?a. ?? `?? Date y?;? " Aeg. No. TDA/ /lJDG E COv/Zr s'' tt 8 v C oacYele e,Ja // ??, ?= 3d4 D?s,. G o1 OoPIy, w sw/ saNdy s??Z -/ G/e?t?, =3D?a? -fi-J ? ,P..?f ?. F ?/PV7(C-a / 4 ,6'A g Tl+ jt?v1- Z t1---I6A7- aic- Wg Z? 7v S/ ? ?'os w= w HL ? p N = 3? x 9 Z? iz ?? P` ? Z z y /Z.:..'911 k?f4 - 0.23 %!Z/.J /yv ? /• -f 6 3.,K /. 7 - Z. 39 -F f -K?s /r4 cr/a// Flesisfa.IGe ?+1,? = 7" Cd -?? T= o, 44 xepa ? B. a ?t?ps .• Z 3 d ° Co Mu = -ry 8 8 ?eo - o.zZ?? i.V- k?s 1,r?4 ' -.Z°a8 /N g z 9 } z. ?? o Kay R i's vcsefI-ed ?Je?P2,v?iCU?2 v t?a,//s. ???ii??i ?Y2.vs ?'sr f yrouNl. S/, eay ,CvYC ?s?o A? F{= W, % S> goS?c r R, ? ??> y= ?zi5 ?? v Bia p?. F 3 Address: 1169 Lexington Ridge Ct Zip: 55121 Lot: 11 Block: 1 Subdivision: Lexington Ridge THE FOLI.OWING ITEMS WERF.Ai'ERH NOT (bMPLETE AT FINAL INSPECTION ON A I Yes No Comments Final grade - 6° from sidin Permanent ste s - garage Permanent ste s- main ent Permanent drivewa Permanent as Retaining Wall or 3:1 Max Slo e Sod/Seeded lawn Trail/curb damage Porch Lower level finish x Deck Fire lace / . Verify with your builder that roof test caps from the plumbing system havc been removed. . Twn off water supply to the outside lawn faucets beforc freeze potenfial exists. . CaL Lhe Criy's Engineering Deparrincn[ at 651-675-5646 prior to working in right-of-way or installing irrigarion system. J BUILDING INSPF.CLOR: CONTRACTOR: Millerville 1566 Murphy Parkwuy MN 55122 ?'7a, 7arP25 2006 RESIDENTIAL BUILDING PERNIIT APPLICATION City Of Eagan 3830 Pilot Koob Road, Eagan MN 55122 Telephone # 651-675-5675 FAX # 651-675-5694 New Conswc6on Reauirements 3 registemd sRe surveys shoxnng sq. fl. of Im, sq. ft of house; and all roofed areas (20qo maximum lot mvera9e allowed) 2 copies of plan showing beam & window s¢es; poured found design, etc. i set of Energy Calwlations 3 copies of Tree Preservabon Plan if bt platled afie 7N193 Rim Joist Delail Ophons sele;.tian sheet (buildings with 3 or less uniLS) Minnegasco mechanical ventilation fortn RemodeVReDairReouirements ? ????Y Use ? Recd? _ Y _ N 2 copies of plan shvHing foo6ngs, beams, jo?s6 i set of Energy Calculaliorrs for heated addilions _ Tree Pres PWn Recd _ Y_ N, 7 site survey lor addifions 8 decks - Tree Pres Required Y_ N Addttion - nMrcate if on-site sephc system On-site Sepbc Syslem _ Y_ N Date S//7` / 07006 ConstruMion Cost 50,000 -?'b OCa Site Address ll( p 9 .tEX,Hfl ? ? / /i i!!? C9l. UniUSte # Description of Work I?y i t h Aw? r P f/el Multi-Family Bldg Y_ N Fireplace(s) _ D _X 1 _ 2 / Property Owner i ? y? ?/lhAu ./ Te /Ir?sra-,Q Telephooe #(/? S/ ) yS'/- 314k Contractor St ?,l Address City State Zip Telephone # ( ) ? COMPLETE THIS AREA ONLY IF CONSTRUCTINCs A NEW BUILDING - Minnesota Rules 7670 CateEOrv 1 _ Minnesota Rules 7672 Energy Code CategOry . Residential Verrtilation Category 1 Worksheet • New Energy Code Worksheet (V submission type) Submdted Submilted • Energy Envelope Calculations Submitted In the last 12 monihs, has the CiTy of Eagan issued a permit for a similar plan based on a master plan8 _ Y _ N If yes, date and address of master plan: Licensed Plumber Mechanical Contractor Sewer/Water Conhactor Telephone #( Telephone # ( Telephone #( I hereby apply for a Residential Building Permit and acknowledge that the information is complete and accurate; that the work will be in conformance with the ordinances and codes of the City of Eagan and the State of MN Statutes; I understand this is not a permit, but only an application for a permit, and work is not to start without a permit; that the work will be in accordance with the approved plan in the case of work which requires a review and approval of plans. Sr? A plicanYs Printed Name 4 D ? A 1C371f 5 Slg [C ik:_ or DO NOT WRITE BELOW THIS LINE Sub Tvqes ? 01 Foundation ? 02 SF Dwelling ? 03 01 of _ plex ? 04 02-plex ? 05 03-plex ? 06 04-plex Work Tvpes ? 31 New ? 32 Additian 1 33 Alteration ? 34 Replacement ? 07 05-plex ? 08 O6-plex ? 09 07-plex ? 10 0&plex ? 11 10-plex ? 12 12-plex DCSCriDt10n: Watar Damaga Valuation i} O 0 U ? 13 16-plex ? 16 Fireplace ? 17 Garage ? 18 Deck "43 19 Lawer Level ? 20 Pool ? 21 Porch (3-sea.) ? 22 PorchlAddn (4-sea.) ? 23 Porch (screen/gazebo) ? 24 Storm Damage ? 25 Miscellaneous ? 30 Accessory Bldg ? 31 Ext. Alt - Multi ? 33 EM. Alt - SF ? 36 Multi Misc. ? 35 Int Improvement ? 38 Demolish Interior ? 44 Siding ? 36 Move Building ? 42 Demolish Foundation ? 45 Fire Repair ? 37 Demolish Building' ? 43 Reroof ? 46 Windows/Doors •Demolifion (EMire Bldg) - Give PCA handout to applicaM Yes Plan Review 100% or 25°k Census Code ? ? I-/ SAC Units a # of Units 1 # of Bldgs • Type of Const J Occupancy ZQ ` ;12 MCES System Zoning City Water Stories Booster Pump Sq. Ft. PRV Length Fire Sprinklered Width _ Footings (new bldg) _ Footings (deck) _ Footings (addition) Foundation Drein Tile Roof Ice & Water Final ?f Framing ? Fireplace _ R.I. _ Air Test _ Final insulation REQUIRED INSPECTIONS Sheetrock ? FinaVC.O. ? . Final/No C.O. S? HVAC Other Pool Ftgs Air/Gas Tests Final _ Siding _ Stucco Lath _ Stone Lath _Brick _ Windows _ Retaining Wall `n 3-IS-°`- Approved By. '/U' , Building Inspector Base Fee Surcharge Plan Review MGES SAC City SAC Utility Connection Charge S&W Permit & Surcharge Treatment Plant License Search Copies Other Total 7P25qs 2oos RESIDENTIAL PLUMBING PeRMiraPPLicarioN CITY OF EAGAN 3830 PILOT KNOB ROAD, EAGAN MN 55122 651-675-5675 Please complete for modifications to existing residential dwellings. Date1ol-7l a? Site Street Address 1 ICOC'1 Le3<< (1L-r-? F\ 1'Zt f?? G?T Unit # Property Owner?y Telephone #( ) Contractor F'--?-'OLoM A)n ?J (u y-6 rb i ()L-n Telephone # PSa) 1/3a Address ?,? // 51 / .?E?>? .40k- City 5?aq n State/94/4'? Zip The Applicant is: _ Owner -eContractor _Other Septic System _ New _ Refurbished Submit 2 sets of plans and MPC license Includes County fee $ 100.00 Per as-built $ 10.00 Alterations to existing dwelling $ 50.00 ? Add plumbing fixtuees. This fee includes installation of a water softener andlor water heater at the same time. If yov are insfailing only a water so/tener and/or water heater, do not complete this section; move to the next section and check the appliance(s) you are installing. _Septic System Abandonment _ Water Turnaround (add $130.00 if a 5/8" meter is required) Other: Water Softener Water Heater $ 15.00 _ new _ replacement Lawn Irrigation _RPZ _PVB _new _repair _rebuild $ 30.00 State Surcharge $ .50 Total $ I hereby apply for a Residential Plumbing Pennit and acknowledge ihat the mto s compiete ana acwrace; wa< <nr work will be in conformance with the ordinances and cq(1 e of the C' E an and the plumbing codes; that I understand this is not a permit, but only an application for a it, w -is n?'d start without a permit and work will be in accordance with the approved plan in the event a plan is req'?Pf djo be revie and approved. ? &11;2/,5 A-RLI?.41l ?? ?x ApplicanYs Printed Name A nYs Signature       þý ý              ÿ  üý û    ÿ þýüû   ú  ÿ ùø÷ ý    ÿ þýüû   öû õ  ÿ ùø÷  ôóòû ñ õ ñð÷ùø÷  ôóï÷ýý î  ñð÷ùø÷  ÷öûïýíôþ÷ ì  ñÿ ëûð  êû ýí  ñêû þëûý  û   ñÿ ÷þëûý     ñÿéþþëûý  ò    ñÿ þëûýè û   ñÿ þëûý    ñþëûý  û   ú îÿ ùø÷  û õ ì îÿ ùø÷  ç õìöï õ ì îùø÷  ç õìöï õ ì îÿ ÷ùø÷  ç õìöï õ ì îÿùø÷  õ ì îÿÿùø÷  õ õ ì îÿèíôíæ ùø÷  û õ ú îÿèíôíæ ùø÷  û       þý ý              ÿ  üý û ñ  îÿèíôíæ ùø÷ ý ñú îÿèíôíæ ùø÷                  ÿÿþý           ÿ   ÿþþý  ÿþþüÿûþþÿ  ýÿþþüÿþþú  ù ø÷ ö ýý ü  þü õþô ó  üþ ÿ     ø÷ ö ü ýòÿ þþ ñð þ  ûþ ú þ óþõ üüý ÿ   þþï þ  øþö  õ îù íìþÿþ þ   ë ê  þÿþ þé è  ýþÿþ þ îù íìþÿþ þ  í ì êþçñ þ  ÿïþæñåäÿ þ  þ  ýäüÿ  þþý þþ ÿ ÿæñåäÿ  þü þæñåäÿ  í ë êåöçñ çñ ï  ê þ  þ  ýäüÿ        þý ý              ÿ  üý û         ÿ    þ  ÿ    ýýüü  û    ýú   û ù øýý÷      ù ÿ    ýý ö  ùõÿ   ö û ùõÿ                  ÿÿ þý ÿ       ÿ þ ý ü  ûú ÿ þ       ýüü              ÿþ   ûü ú               ÿ þýýü  û ú ù ÿø  ÷ ú  ÿø                   ÿÿ þþýü ÿ       ÿ þ ý ü  ûú ÿ þ        üûû            ÿ þý ÿ  úû  ù        ÿþýü             ýüü               ÿþ   ûü ú          ÿ þ         ÿûúú          ÿþ  ýü ÿþ ùú  ÿøÿ      ÿþý  üý     ûúùøýþ     ÷ ùøýþ      ùøýþ     ùøýþ   ö õùôóóòû  ö ñ ÷ ôóóòû  ö ñ ôóóòû  ö ñ ú ðïðî ôóóòû                ÿ þ ÿÿ ýýüüûú ÿ       ÿþ    ÿÿÿ  þ  þ ý   ÿÿÿ üþÿ ûþ þ   úûù Oct 04 2014 10:10AM HP Fax page 4 I Use BLUE or BLACK!nk ' � ForOfficeUse---------� I I � j Pem�it#' � �J i Clty of Ea�an � p it Fee �� � �� 3830 Pliot Knob Road Eegen MN 55122 j Date Received ���� j Phone:(651)675-5675 I I Fax:(651)675-5694 I Staff� I I I v�������� �������J 014 RESIDENTIAL BUILDING PERMIT APP�ICATION Date: ( ��! � Site Address: I I�� �j 1L•a.!(i.�� Unit#: Name: ��►�z,— ll' 1���- Phone: <"J.�z`"�I�"� ;�c'S y'` ResldenV Owner Address�city�zip: _��'l�tL h-S �c�v'-� Applicant is: Owner 'V Contractor Typ@ C�WOrk �escription oi wark: �e'h'n-- ���� Construction Cost: �3`�� � ' 3� MuNi-Family Building:(Yes�I No� Company:vAt�i�S'� ��-N�C-=�y� r' : ��---- Contact: /.���� Contractor Address:���� ��S�'-'�t � i���� �G'� '�j�/ City: J�r'�'"�'��-E''/`� � � State:�`�Zip:S�''ly7 Phone: �r�'L�Z?� 3y5 Ernail:/�t.=�?,c�r.r�>�����C��h+�� License#•.lx%-CG��,� ��/ 3 Lead Certificate#: .�� �/`Z 7 S� � If the project is exempt frorn lead certlfieation, please explain why: (see Page 3 for additional information) COMPLETE THtS AREA ONLY IF CONSTRUCTING A NEW BUILDING In ihe last 12 months, has the City of Eagan issued a permit for a similar plan based cn a master plen? _Yes _No If yes,date and address of master plan: Licensed Plumber: Phone: Mechanical Contractor: Phone: Sewer&Water Contractcr: Phone: NOTE:F)ans and supporting documents that you submit are cons/dered to be publlc lnfo�ma#lon. Portlons of the Informat/on may be classlt/ed as non public if you provide speciflc reasons that would permit the Cfty to cortclude that the are trade secrets. CALL BEFORE YOU DIG. Call Gopher State One Cali at 651 4540002 for protedion against underground u[ility damage. Call48 hours before you intend t0 dig t0 leceive lOC2tes of underground utilities. www. o herstateonecall.or I hereby adcnowledge that tnis informalion is complete and accurate;that the work will be in conformance with the ordinances and codes o(the Cfty af Eagan; that I understand this is not a permlt, but only an application for a permft, and work is not to start without a permit; that the wotk will be in accordance with Ihe approved plan in the case of work which requires a review and approval of plans. Exterior authorized by a bullding permlt Issued In acoordance wlth the Mlnnesota State Building Code must be Completed wlfhln 180 da pe I1lssuance. � x ��'v � x ��� Applicant's Printed Name Applicant's Slgnature Page 1 of 3