3060 Poppler LaneCITY OF EAGAN Remarks
/+dditio Popplers Homestead Lot 5 eik ? Parcel 1?0??581?OO?Oi0?00?tr
n
Owner?uAj a Y' o.z? 0 C) 11 t n. n 0 tr i. )Street 3060 Poppler Lane State Eagan,MN 55121..
Improvement Date Amount Annual Vears Payment Receipt Date
STREET SURF.
STREET RESTOR.
GRADING
SAN SEW TRUNK 1
970 125, 0 Z.
SEWER LATEftAL .
WATERMAIN
WATER LATERAL
WATER AREA 1 77 160.00 10.66 15 . o0
STORM SEW TRK
STORM SEW LAT
CURB & GUTTER
SIOEWALK
STREET LIGHT
WATER CONN.
BUILDING PER.
SAC
PARK
Date: 06/14/05 Revision Date: 6/14/2005
Site Information
Address 1: 3060 Popler Lane
Address 2:
City: Eagan County:
Application Information
Business Name: Air Mechanical Inc.
Contact Person: Brian Ebert
New Construction
Project #:
Lot: Block:
Subdivision:
MN Contractor License #:
Office Ph: 763-746-3753 Fax: 763-434-1699 Cell Ph:
Address 1: 16411 Aberdeen St. N. E.
City: Ham Lake State: Mn. Zip Code: 55304
House Details
Square Feet: 4244 sq. ft. Avg. Ceiling Ht: 8 ft. Number of Bedrooms: 3
Ventilation : Batanced
Total Ventilation Capacity : 149 cfm.
Minimum Continuous Ventilation :60cfm.
Intermittent Ventilation: 89 cfm.
Combustion Appliance
Water Heater: Power Vent Input BTUs: 50,000 Independently Vented
Furnace/Boiler: Direct VenUSealed Combustion Input BTUs: 112,000 Independently Vented
Other Combustion Appliances
Gas Fired Direct Vent Fireplace(s): Yes Gas Fired Power Vent Fireplace(s): No
Gas Fired Natural Draft Fireplace(s): No Solid Fuel Appliance(s): No
Exhaust Equipment
Continuous Exhaust Ventilation Capacity (cfm): NA Clothes Dryer (cfm): 135
Exhaust Fan Rating (cfm): 350
Make-Up Air
No Make-Up Air Required 6y Code
Combustion Air
Round Rigid Required: 4 inches or Insulated Flex: 5 inches
Applicant Name (print): gr i,;,., ELe„A- Signature/Date:? 61)`( o_5,
Code Official (print):
Signature/Date:
C 2004 CenterPoinf Hnergy Minnegasco. 2004 Mechanical Code Guidelines. Page 1
m
(o
m
A
W
?
%q???rmtfiRutt Gdisr p7lte?,i'x+?f
•kYltuh; lr:'a7'? :ti ol` f1[Yyfi •EE lY 00
I[ UWCC'Wj' .,f: i w4'C[Yr1W1ed 1kA
'000 d11i, 14itr:'n1 i'IL:%igI
?/Yatl' U w7eG.C w Ws U? fI1P dli4
1? J?flGW?? ? .
3aighwft,&i„M
9w
? O/2'
-?O(OD
P(.giOjOZ 4`-04L
"-° - v
The right hee{ was nuchd (7-1 1/2° x 0`-3 112" far a ledger. Ranforce the M:e!?wtY a i,"2':DX ar QSe
plywood gusset on 6cth sdftof the Cruss, hppiy 5troctura{ adheswe for wocd tq tle9mj*be'are
xiuruig them in place wih a aunumum of (3)-4 Od nads m each member anci on bod stdm ef tk tri55.
NI m?dVlL bg?lrystyl?a. JM+i? rl an^'}?a'p b0a/M tludswy?c tle
Pp?Y?f Me?6hul.UG '?9'?ae u?phsl+nBVwd+a+.w IrW ?l?I'^i?
a?1adliekM wJ v?OM ?W Mr a?w.i?mrtd Ns6?R It4
` IJELSTRIK.7. LIC.. CAU CWit. IM1:OT'RIGMI'
a
N
p
ka
td
a
A
*
#
?
O
NpSaN SfRUC1WBft Ei$NE9NC J031277
` k"
2820 STEIN BOllUYf/tD ._ (71 03 I i77?i 9.I0; Ut I J?{" FiHI CWRE W1 5A07
(7rs) eas-sTruss M 5hiR ,0."" i
Lon.
?
r?
m
n
..
?
N
?
?
C .a
v
?
?
n,
m
?
?
N
?
a
?
N
i
m
cn
N
U
C
?
N
W
E
0
2
L
N
43 ?
N ?
m
[ I
•M ?
C
L
O
L
~ O6Y4v?- o'a"7^ ?Nlt pYM. aLMns JM ?rrw?pnpiy
PoRhM lYL',AyR,ILC. Try wbM
w_•tue+din?abw?a?p?tl
10 MIlelmt4 w/wrae,oJscejrn;hwtlftmprpb ? i
NM-5TRuc?, «c. eAU cwae,.v,?,?FM,
m
El ?
Tru55 D4GT
?
28X40
? ncr-bv c?•-ti,r •t,? ? ?i-fs nran, pi+cah:
f+•.?:,
.
?r .?:....: ' -
: .. ?. ;:i Ly me
iS.iM....
•:c J
?
.
. : a...
41 .ai1lo-, jF, ?i•s. ... .: oI :LU "
[hte.l04La 0.
9
\V /
N STRUCSURAL ENCIME8RINC p? ?
o ? Wo
2620 srew eoui,EV,wo! J031 277 s?
O m EAV CI
A?Rf. W! SC?Ot . JC
00 "z?7 ?10.7-0 I/4 ?•=
(»s) a3e-9,9. Truss D5 t D4GT
W ,d
.. . 9E . _. ?A/P .
[
C
?R
a
aN
1 m
g?
A
6
am
•• W
A •V N
D
a?
z
?
r
mi
N3
i
A
C
n D
?j ?
m?
Z -
L1 ?
W
A
r
W
?-
01
.y. ?
U LD
?
UI
P
d A
A ?
P
v
m
M
m
ti
?
U
f.7 . ,
; ? w? a33 c ?- LelqSO ?t 5s53. $?
c) O RESIDENTIAL BUILDING
-70 - ?
( p,, Permit Application PP '
City Of Eagan tD ?? S 2. i$ °1 b• 5?
3830 Pilot Knob Road, Eagan MN 55122` Telephone # 651-675-5675 FAX # 651-675-5694 ? ?? 1 Lt: 9 ?
New ConsWCtion Reauirements
3 registered site surveys showifg sq. ft. of lot, sq. tt. of house; and all roofed areas
(20% maximum lot coverege ellowed)
2 mpies of plan showing beam & window sizes; poured found design, etc.
1 setof Energy Calalations
3 copies W Tree Pmservalion Plan if lot platted after 711193
Rim Joist Defail Op6ons seledion sheet (bldgs with 3 or lass units
RemodeVReoair Reauirements
2 copies of plan
1 set of Energy Calculations for heated addi6ons
1 sife survey Por addilions & tledcs
AtldiNon - iridicate ifonsife sepfic system
orr
Cert of Survey Recd
J&- ' ?
Tree Pres Plan Recd
)aLTree Pres Not Reod _
_ On-site Septic System
DaYe * l Z1i l
Si[e Address 9,0O 3?
30t0 0 Construction Cost
pOp/??a L44'4k5 UniUSte #
Description of Work ? l ro1N 'D .
Multi-Family Bldg _ YIg. N Fireplace(s) _ 0 X 1 _ 2
Property Owner FQ.( LdZp g}{ ' ?-!? V551 Telephone # (??? ) ? 3 ? ' / 'C L8
Contractor t'"(o RN + N GS'T'alZ f-10 Me-ri l hl G.
Address 1284
S[a[e t"'I ! N nl • 5 Iq57" <kv. r-t,w,
Zip '"?j?'j'?'?'30 city euc t2ivefz
,4
Telephone #((,(Z,) 24(O 'I9/
COMPLETE THIS AREA ONLY IF CC
Energy Code Category Minnesota Rules 7670 Cateeorv 1
. Residential Ventilation Category t '
(J submission type) Submitted
?. .? Energy Envelope Calculations Su6
,
A NEW BUILDING
e r ? • INew Energy Cade Worksheet
Op ?III[7L??1-
? `Suhmitted
auCI)r2l& ??,>>1°?
Ji c?s1-._.??-?t
Licensed Plumber ielephone
BY-
Mechanical Contractor plCl R MGE44 n! I C A L Telephone
Sewer/Water Coniractor VfQ&);jdj9&1> 1V1G?i7-AL Telephone #65j) qSZ SS,,-S
I hereby apply for a Residential Building Permit and acknowledge that the information is complete and accurate;
that the work will be in conformance with the ordinances and codes of the City of Eagan and the State of MN
Statutes; I understand this is not a permit, but only an application for a permit, and work is not to start without a
permit; that the work will be in accordance with the approved plan in the case of work which requires a review and
approval of plans.
V, lG{G 5C17-4t1?? &"
Applicant's Printed Name Applicant's Signature
,
OFFICE USE ONLY
,
Sub Types
? Ot Foundation ? 07 05-plex ? 13 16-plex ? 20 Pool ? 30 Accessory Bldg
x 02 SF Dwelling ? 08 06-plex ? 16 Fireplace ? 21 Porch (3-sea.) ? 31 Ext. Alt- Multi
? 03 01 of _ plex ? 09 07-plex ? 17 Garage ? 22 PorchlAddn. (4-sea.) ? 33 Ext. Alt - SF
? 04 02-plex ? 10 08-plex ? 18 Deck ? 23 Porch (screenlgazebo) ? 36 Muiti Misc.
? 05 03-plex ? 11 10-plex ? 19 Lower Level ? 24 Storm Damage
? 06 04-plex ? 12 12-plex Plbg_Yor_N ? 25 Miscellane0u5
Work Types
'K 31 New ? 35 Int Improvement ? 38 Demolish (Interior) ? 44 Siding •`
? 32 Addition ? 36 Move Bldg. :. . ?. 42 Demolish (FOUndation) ?. 45 Fire Repair
? 33 Alteration ? 37 Demolish (Bldg)" ? 43 Reroof ? 46 Windows/DOOrs
? 34 Replacement 'Demolitlon (Entire Bldg) - Give PCA handout to applicant
Valuation ?? ?- a
-r-r- Occupancy ? MC/ES System
Census Code i0 r Zoning City Water
SAC Units Stories ?_ . Booster Pump
Nbr. of Units I Sq. Ft. PRV
Nbr. of Bldgs P Length l00,- Fire Sprinklered
Type of Const Width
REQUIRED INSPECTIONS
'V, Footings(new bldg) ? FinaUC.O.
_ Footings (deck) , _ . FinallNo C.O.
Footings (addirion) _ Plumbing
'yt Foundarion _ HVAC
Drain Tile Other
Roof Ice & Water Fi nal Pool t s Au/Gas Tests Final
Framing _ Siding Siuc Stone
? Fireplace K R.I. ?{Air Test ?[ Final _ Windows (n placement)
Insularion ?? _ Reraining Wall
?-
Approved By Building Inspector
Base Fee
Surcharge
Plan Review
MC/ES SAC
City SAC
Utility Connection Charge
S&W Permit & Surcharge
Treatment Plant
License Search
Copies
Other
Total
?1Y 7)f
z
.?i'0! o
I ?G?b
Xo?' --
/ 3`1'
x s-q =
???. ol5/ X
Ljv X 3 0
STa,rP
;?/7 Z-16-6
171
"2 j aa. .0
/! a V Q
r
. F"?OM : RRI
?
F,?41,; tN]. . i-lay. 31 2003 07,:35Pi•I P2
MNr.}ieck COMPLIANCC 3EFOiiT
Minnesota L;.7oryy Co^e
uNe.heck Sof.tware ve7:sion
COUNTY: Oakota
STATL": N.innesCtd
2-ONE: 2
CONSTROCTI()h TYPE: Si.n_y].A Vdm11'y
naTs: 5-11-2003
DATE ilF PLANS: 5-12--03
PRUJFCT ICFOR_MATLON:
---?TOUSS:t RG7IDENCE
COMPANY Zh*FORA9rlTi:ON:
ARI
7943 R_ypDE I9LF11VD I:IR.
HLooMINGTON, MN 55438
COMPLIANCE: PA53ES
Aequired'UA = 718
Your Home = 712
0.8% Better Than Code
i
+ _.. .. ___
I
I
i CI1er.Ked i?y/Cate
I
A:ea or CaviCy Cor.t. Glazing/DOr,r
Ueri.meter !?-Valu e k:-Valua U--Value JA
. -.--------------.----------- .__-..
CEILINGS T 14^36 _____.-.--
46.0 -----.---_
0.0 ____----`- `----
33
WALLS: Wood Frame, 16" O.C. 2556 19.0 d.0 131.
WAZLS: Wood c^xame, 16" C.C. 264 11.6 4,17 7.U
BSMT: Conc. 8.0' hti'7.4' bg/8.0' insttl 1830 5.0 0.0 155
GLP..zING: wincloNS r>r Goors, Abave Grade 982 0.370 179
GI.AZING: Windows or Goors, Abcve Gratle 4'.i 0 .370 i7
DOORS 48 0.350 - 17
?"LOOR3: Over Outside Air 36 30.0 0.0 1
SLAB FLOORS: Unhear.ed, G.0" ir.3ui. 152 0.0 156
HVAC EQOIpMECST: 'Curnace, 92.0 AEUE
------
-----
-------
-------------------------
COMPZTANCE STATEMENT The propased buildina de.sign dascribed here is
ennsistent with the Luildir;_-i plar.e, sp°cific acions, and otha:: caLcular_ions
submitted with 'the permit application. 'i'he pxOp03eCl buildir.g has been
oi: kh? b7in
s
deslgned to meet th- requiremer.t. ztcsota E nergy Code .
/
'
i
D
il
l U t
`?
n/?k Pa
gner
c
es/
es
Bu a e
A _
• ~ '
,? -' LOT SURVEY CHECKLIST FOR RESIDENTIAL
' BUILDING PERMIT APPLICATION '
r PROPERTY LEGAL: ?07 S ?oF>PG?R Nom?src--a os
., DATE OF SURVEY: Co - O(
LATEST REVISION: ? - 13 - 03
m
rn
c
a
s
U
Q
O ?
?
Q
DOCUMENT STANDARDS
?? ? • Registered Land Surveyor signature and company
?? ? • Building PertnitApplicant
ral ? ? • Legal description
,9'. ? ? • Address
i3? O 0 • North artow and scale
401;? • House type (rembler, walkout, split wlo, split entry, lookout, etc.)
? ? • Directional drainage arrows wfth slopelgradient °k
-Cdi; • Proposedlexisting sewer and water services S invert elevabon
? ? . SVeetname
? ? OW@6 • Driveway
y7/p ? • Lot Square Footage
? ? ? • lot Coverage
ELEVATIONS
?
?
• Existin
Sewer service (or Proposed)
? • Property comers
f;? ? ? . Top of curb at the driveway and property line extensions
U-?'Cl ? • Elevations of any existing adjacent homes
>C 0 ? • Adequate footing depth of structures due to adjacent udlity trenches
? V? • Waterways (pond, stream, etc.)
Pro ose
}7 ? • Garegefloor
L9? ? ? • Basement floor 12"0 ? • Lowest exposed elevation (waikouUwindow)
? ? ? • Property comers 4*
f1/0 ? • Front and rear of home at the foundation
PONDING AREA fif aDolicable
? L?7 ? • Easement line
? I? ? . NWL .
? GY ? • HWL
0 ? • Pond # designation
fl
El
i
O
? GY ? ver
ow
• Emergency
evat
on
? (R/ ? • Pond/WeUand bufferdelineation
/ DIMENSIONS
?" 0 ? • Lot IinesBearings & dimensions
?? • Right-of-way and sVeet width (to 6ack of curb) 4q
t5? ?? • Proposed home dimen"o? ncluding any proposed decks, overhangs greater than 2', porches, etc.
/ (i.e. all structures requirin9 permanent footings)
Ix ?? • Show all easements of record and any City utilides within tlwse easements
X? • Setbacks of proposed structure and sideyard setback of adjacent exisFlng structures*
?V? • Retaining wall requirements, if any /
Reviewed:
`03
r
G:/FORMS/Building Permit Appliwdon
, Q-eF LC?? ?? LE, CCIC I
. ,
"TREE PRESERVATION PLAN SUMNtM
CITY OF EAGAN FORE57RY DIVISION
' 651-675•5300
(SEE ATTACHMENTS)
Development FC)pPl.A12 ?AUMnjztl?
Lot Number 1 Block Number I
Address 3Ub FOa(-?M(Z t f4"N-6
Builder ?CNZf.?i t?'??rYiZ nvviM?
CL N-TLI-('T t F'l G K s-CR i`1'US
Pl-1Or.sC ` 617 - 7,16 - q qG`I
Tree Protection Reauirements:
4-1- Tree Fencing
Oak Tree Pruning (Immediately seal wounds during April 1 to July 31)
Therapeutic Pruning
Retaining Wall
Other:
Replacement Trees:
?
Attachments:
--?
?--
Additional Notes:
Not Required
As Follows:
Yes
Mo
..?..
EAGAN FORESTRY DIVI510N
REV6EWED
BY
?AYE
H:lghove12002f11e1lreepreslTree Preservation Plan Summary-2002
01n682 10;27/2? TOUS51. FARROKH 6 FARNAZ ? y`
g`
BARK: qpPROXIAIATE . f?? L? ?., ? [i[v•aea.o ?y
ADVANCE SURVEYING & ENGINEERING CO. ENCHM C""" a"4N -
RIM OF MANHOLE LOCA110N OP :.... ppOPERTY CORNER
$ i00 S. HH)'. No. 101 Minnetonka. MN 55345 PhOn¢ (952) 474 7964 F2X (952) 474 8267 ELE\'.=8929 EJ]STING SEWER? -FAKS ON EOGE
esx.z OT. ,. _ ... pF AAANHOLE lO
5 89'55'07° E"esi i-, .`(vux* mon i
sLRVE}'FOK: FARROKH & FARNAZ TOUSSI
INV=86J.D1 _-,3a.sz-- 2.0% ? 2.0% ?- 890
? DRAFTED: ]une 18, 2001 5 s c B? 89.5
$UR??EYE?: June. _OOI ? ?.? 2.0 R 16' pRAINAGE & ?
? ozasos i -? ? ILIiY EASEMENT ?i
; N? p :S za' nsN
REN'ISED: July 30. ?001 to shnw newproposed dweltin2 ? +' p ? p'ce Ooc. t38aa65 - //'
------- _ _ _ - _ - - ' _ ' - _ - - - r-
?LE\'15ED: .Auc 13. 2003 to moee proposed dwellmg 10' s'wth and west to setback line. 3DA ?
__'
'___ I _""_"J0.0__"' =aso.
a
RE\'15ED: Aug 13. 2005 to add additional itnns per Cin? of Eacan. ?'?.2
REVISED: Sept23,2003toshoa'changesperCiryofEngan. rF` P ?
RE\'ISED: Sept 29. 2003 to shou' erade dhxnmes alon_ nor[h property Iine. 'r 1 30.6 yo. ? wnLK oUT 1ts=o
REl'ISED: Oci 9, 2003"ro show changes per Ciry ofEapan. ? o° ---------- '- CoURT ?--? --
r
w '? ? 5 I I
LEGALDESCRIPTION: I Q o N xWOY.77 I
LoL ?. Pnppler Homesteads, Dakota County, Minnesota. ?, o? e'wxe
ADDRESS s'^ o I ??? ?
• wm o ? pO ?
3060 Poppizr Lnne. Exean. Minnesotn SSl?? 34 e-B w
w o j o
PRDPOSED ELEVATIONS: m o
0
Top of founda[ion 898.9. Lowes Floor 895.9, Garege Flnor 898A ? ?l ?o a 0
Benchmxrk* 89?.9,'Rim oCmunhole us shoum I?- M o
L1M7TATI0NS. ? 'a'P1NE z
i'he +cnEx of our services fnr this jnb is as follows 8950 B.1 ` .es?.s
1. Shmcing the lenerth and direction of boundury lines oTihe legal descripcion which you fumSshed. S,`-l 1cje' I I
2. Sho..'ing [hr Iocazino of existinc impmvremems we deemed importxnt
3. Seuing new' monumenu or verifyinc esistinc monumenb ro marA the wmers o£the property.
4. Show'in,_ ezistine spot elevations necesvary ro shoa' devation differences on the site.
5. N'hile we shnH' a proposed location for this home. H'e are not as familiar wi[h your house plans p0.?P ? 3 ?
as you and your architect and/or builJer xre. ChecA wr proposed locaiinn anJ sieine of the home ? ag? p 60 P? ?5???
and y:vd ;•radea curefully to see thut they match yom' pl:uis before com[metion becins. Also, we are ? ` I ? ?
5.0
nnr a.v famitiar with local codes az the local 6uildin, official and zoning olTciai in this commufliry O?.' ?
are. Bz .ure m.no?+ this survey to these officials. o.' ar.}' olher ofticixlti ihai may havejurisdiction ?0 D ?-F--?
0 n
II ? i0.o
o.er the hninc nnd its siiinc. and obeain their xppro.a!x before beginnin, wnstmction. pi 30 - 5.0
i_
F. N?e hace Fro` ideJ . henclnnark for your use in deiennininm elevations for cnnsvuction on U»s ? ?
site. use thai bcnchm;vk and no[hing else for thai punose. Check the'eleeation of al leasl one other ?.esa5 ? ? 8 p g?x= ?rR ? I ?
o1 .,; i ? mix ss.i ? i T ?x ? I - I ..¢.x
feamrc rhuwnmveril';'yourdevations. yy?? y ?.?C
m ? . o,
L? S vpb?5 l0??'?29(.-`?9(0?' ssz,
ST.4?'DARDSI'\4BOLSSCON?`[NTIONS? e?
"1. Denuic> I"_,. ID pipe wiih piaseic plue bearinrt Siare Liceme Number 92i5. s'et. unles's em.a --105.22-- '' esz.'n
otherw'i.e noled. Prnpused ele•':niuns arr xho..n a'ith a box arnund them. while existine elevution> E esa.x I? nse.ax S d9'S5'49" E _ N` °` " I s'.3
?rr ,ho.? i• w nhnul d hox. .4ne N' indicate che propu.ed floe- of slom, ??'ater on the cite. n ?,y /??-? ..-.
1 h:rh. wrtd\ 1L•:i, Ihls plai . p«lilcauw repnn u: wrve?- u?ae prepaad by ine or under mv direct V r? Z '2%"'?mum Sle?pes
?
super, i>ior.:mu ih:u I an; a li.cn.cd Prole.sional Emcineer and Profe..ional Surveyo: under [he 20 o to 20 ao a Retatniog Wa11 Wdl
I:dyulr?
Iv?c> nl iim Siaic of A9m l:? LOT=16.948.4 SQ.FT.
HOUSE GOOTFRINT=1,002.6 SQ.FT.
- q? SCALE IN FEET CO?FRAGE=127R
s?o I?I w? n.-. tin. a,?nas
J niexli. Parkcr P E. ti P ti. Nn. ?)l:i
'f ree (-ryr)
? . R
?
5T7- ?
??- At_q .
c) L---
GL?-
`1?. ? v
rcr.t,ttvtU AUG 8 1990
s
t
.?
SEVERSON, WILCO%& SHELDON, P.A.
APROFESSIONALASSOCIATTON
ATI'ORNEYS AT LAW
LARRYS.SEVERSON•
JAME3 F. SHELDON
J. PATRICIt WILCOX'
TEAENCE P. DURKIN
MICFIAEL G. DOUCHERTY
MICHAEL E. MOLENDA'•
PAULd. 3TiER
'A140 LiCEN3EU IN IOWA
••AL50 UCEN6ED IN N7SCONSIN
... ALAO LICENSED IN NEBRASIU
August 7, 1990
Bruce Allel.rC
City of Eagan
3830 P?lot Knob Road
P.O, PoX 21199
Eagan, MN 55121
600 MIDWAY NATIONAL BANK BUILDINC
7300 WEST 147fH STREET
APPLE VALLEY, MINNESOTA 66124
(612) 432-3136
TELEFAX NUMBER 432-3780
RE: Lots 4 and 5, Poppler Homestead -"*
Our File No. 206-4768
KENNETH R. HAI.L
'•'SCOTI' D. JOHNSTON
JOSEPH P. EARLEY
LOREN M.SOLFEST
CHRISTiNE M.SCOTILLO
ANNETPE M. MAFiGARIT
DANIEL M.SHERIDAN
OFCOVNSEL
JOHN E. VURELICH
Dear Bruce:
I have recently received a letter from Rollie Crawford, the attorney
for the Popplers, a copy of which I have attached hereto. Mr.
Crawford has attached a letter from you to him dated April 10, 1990
expressing concern by the City to acquire an additional permanent
easement over property now encumbered by a temporary easement.
My understanding of the facts are that the temporary easement arose
out of the construction of a sanitary sewer sometime during the early
1980s. That the property in question is part of land that was
previously platted by Mr. Poppler. Although I do not have the
document in front of ine, I would have to assume that the temporary
easement designated purpose was for the construction of the sanitary
sewer line. ;
Based on the foregoing facts, 2 sincerely concur with the arguments
raised by Mr. Crawford in his letter that the easement has expired as
a matter of law, and without anything further, the City has an
obligation to remove any potential cloud on title. Under the present
law, Mr. Crawford could request the City to release their interest in
the temporary easement and if the City failed to do so, Mr. Crawford
could bring an action against the City and obtain an order of the
court requiring the City to pay for any and all costs incurred by Mr.
Crawford in obtaining the release. If my understanding of the facts
is mistaken, would you please let me know. Otherwise, since the
easement is temporary in nature, a vacation of the easement would not
be required but rather an affidavit executed by somebody with actual
knowledge of the termination of the purpose for the easement would
Mr. Bruce Allen
August 7, 1990
Page Two
act as a satisfaction or release of the City's interest in the
temporary easement.
If you have any questions or concerns relating to the above items,
please feel free to be in contact with me.
Sincerely,
SEVERSON, WILCOX & SHELDON, P.A.
Michael G. Dougherty
MGD/djk
Enclosure
cc: -iQtike Foertsch (w/enc)
Dale Runkle (w/enc)
LAW OFFICES
LeVander, Gillen, Miller, Anderson & Kuntz
402 DROVERS BANK BLOG. • 633 SOUTH l'ONCORD ST, • P.O. BOX 298
SOUTH ST. FAIIL. MN 55075A299 • 1612- 451-1831 • FAX i6121 450?7384
August 1, 1990
Mr. Michael Dougherty, Esq.
Severson, Wilcox & Sheldon
7300 W. 147th Street
Apple Valley, MN 55124
Re: Poppler Homestead
Gentlemen:
Mr. Dale Runkle
Municipal Center
3830 Pilot Knob Road
Eagan, MN 55122-1897
HAROLO L[VANDER
ARTHUR GILLEN
ROGER C. MILLER
PAl1L H. ANDERSON
TIMOTHY J. MUNT2
OANIEL J. 6EESON
ROLUN H, CRHWFORO
KELLY NEILAN KRUEI_L
The above-named subdivision was given preliminary approval by
the City Council in January, 1990. In our discussions and
corxespondence with staff leading to the final platting
procedure we have encountered a serious situation. In our
desire to sell some of the existing previously platted lots to
raise the cash to meet the demands of the new project, we
discovered an existing temporary easement that had never been
released.
While I believe that the easement has expired as a matter of
law, and I could obtain such a ruling, the covenient way for
this to be handled would be for us to be given a release for
recording by the City. City staff has refused to do so on the
basis of "policy." Please note the copy of the letter dated
April 10th from Bruce Allen attached. If the letter correctly
states the policy, I would like to see that policy in writing,
when it was adopted by the Council, and the statutory authority
for it.
If, as I suspect, there is no such policy, perhaps I could
receive an executed release of the easement within five days of
the date of this letter.
Mr. Allen states in his letter that the
certain other permanent easements, and we
other "financial requirements" in connect
plat. We will be most happy to discuss
Poppler can achieve their mutual goals
release of the tempocary easement.
Sinc y,
rin ?? Ro H. Crawford
City is desirous of
are aware of certain
ion with the proposed
how the City and Mr.
upon receipt of the
RHC:tc
Enclosure
cc: Lawrence Poppler
Clty OF
3830 PILOT KNUd ROAD THOMA5 ECw+
EAGAN, A1INNESOTA 55122-1897 A&W
PHONE: (612) 454-810D MVID K. GUSTAfSpN
FAX: (614) 454-8363 DAMEU+xOiEn
nM vnwI.Errtv
n+eoooae wAtrnEa
April 10, 1990 COi"1AF1"1bG5
TNCNV.S HEDGES
Gty Mminsvawr
LAWRENCE G. POPPLER EucENEVaN ovExeEKE
3045 POPYLER LANE cly cwit
EAGAN. MN. 55121
RE: Release of Temporary Easement
Lots 4& 5, Poppler Homestead
Dear Mr. Poppler:
This letter is to provide you with a written record of the City of Eagan's policy
an releasing easements. As a rule, the City does not release permanent or
temporary easements until replacement easements that may be required have been
granted.
The temporary easement (Document #378234) that you have requested being released
6y the City sits on both sides of a 10' wide permaneat easement. This easement
sits over a 22' deep sanitary sewez. The ideal easement width is 2 times the
sewer depth. As this is often impractical, we will normally ask for somewhat
less than this. In your case, we would want at least a 30' wide easement. This
would add an additional 10' of permanent easement to both Lots 4 and 5.
As these are quite wide lots, we feel a 15' easement on each shouid not affect
any future building placement.
In addition to the increased easement over lots 4 and 5, the City, as part of
the proposed replat of Poppler Homesteads, will requiie an additional utility
easement in the northwest corner of Outlot A. The attached plat map shows a 30'
x 40' easement that will be required for future storm sewer. This can be
ded'.cated on Lot 9 on the new plac of Poppler Homesteads No. 2.
Please cor.tact me or Ed Kirscht at the City offices concernir.g drawing up a new
easeixent and releasing the oider temporary easemenc. Contact us a 454-8100.
I have enclosed a map uf this easement and the proposed additional easenent.
Sincerely, ours,
Bruce Allen
Engineering Technician
cc; Thomas A. Colbert, Director of Public Works
BA/jf
THE LONE OAK TREE...THE SYMBOL OF STRENGTH AND GROWfH IN OUR COMMUNIlY
Equal Opportunity/Aftirmative Action Employer
oF
3830 PILOT KNOB ROAD THQWS ECv4N
EAGAN, MINNESOTA 55142-1897 MayOf
PHONE: (612) 454-8100 DnMD K. GuSTnFFSON
FAX: (612) 454-8363 7Ah"EI.A McCREA
TIM PAWIEMY
THEODORE WACHIER
Caricil Members
April 101 1990 T*pM^SHEOGEs
Ctty Adminis[rator
EUGENE VAN OVFRBEKE
CM Ckrk
LAWRENCL+ G. POPYLER
3045 POPPLER LANE
EAGANI MN. 55121
RE: Release of Temporary Easement
Lots 4 8 5, Poppler Homestead
Dear Mr. Poppler:
This letter is to provide you with a written record of the City of
Eagan's policy on releasing easements. As a rule, the City does
not release permanent or temporary easements until replacement
easements that may be required have been granted.
The temporary easement (Document #378234) that you have requested
being released by the City sits on both sides of a 10' wide
permanent easement. This easement sits over a 22' deep sanitary
sewer. The ideal easement width is 2 times the sewer depth. As
this is often impractical, we will normally ask for somewhat less
than this. In your case, we would want at least a 30' wide
easement. This would add an additional 10' of permanent easement
to both Lots 4 and 5.
As these are quite wide lots, we feel a 15' easement on each should
not affect any future building placement.
Please contact me or Ed Kirscht at the City offices concerning
drawing up a new easement and releasing the older temporary
easement. Contact us a 454-8100. I have enclosed a map of this
easement and the proposed additional easement.
Sincerely yours,
r=,- N??----
Bruce Allen
Engineering Technician
cc: Thomas A. Colbert, Director of Public Works
BA/jf
THE LONE OAK TREE...THE SYMBOL OF STRENGTH AND GROWfH IN OUR COMMUNITY
Equal OpportunNy/Affirmatfve Actfon Employer
? ' ' , .a. ti'• ?. .
,
_643.59
I3A1 ea .
• ,?,? ? ?
.
l ' ? ? ' ' ? _ Pondin9 foseinen? ? e?V ?
Gbc. No 3189l4
T ' ? `l
? ? f/.?)USE 1' I \ , 1 I ?S 333' OF K J.i9' O. [. A. 1 e
? /S? ?i;kJPt/eV I `.v.i ??•tiC NJUSE ? • /
? L _v?cnJ J .. • I \ ? ? SNV,('E UNf !OL'A/E'O ?UNf /S, M8B `i N
I \ ` e O-
cttv 8;?5:2
? . . - . q ?to
??¢
?
s 5¢
; ?_ 1 ? ? ? ? ?•. ____,emP ?. P¢r
? .
1 _ _ - ---- - ---- --
w . •
? -- s?
. f - :i ,. ?'.• . - ?_ _ _ . _.. _ Bo -
- - - - ?-? ? .
---
--
?r,
40.26 , . e..v
i3 a.73 3 ia . ?o r-- -- ?--- , ? C K S4.?S9 ?"• ?Ex??
Ja .' •..,'
? ' _ U - ----- -.. -
.'
-- ? ? - -- --
, - _ . . --- -
e? C . C 2" NP N.Ir CAS ?fAPP OX ? ? ? ?-
? . f "_ ._'_ _._ _._. _ ..._. . _.._. .. ? .'__' •.'?"_ _'?'._'....
a ? .. B? iE0 ECfC lAOP.POA.) ? a
,?oodwoy Eosemenf Per
. ?
?? ' . "___•'__
\ " ?1 ? . . ,•`' ?. ? C .. ? T
?a°o \ Q
-? ?_.... p ma th ,d4`o .. v tio' O b
? v . ?b ?t• ' ?ti? I ? ? ?
Y
f NOUS'EC y
Cl+vvnYAW, !J ( r?Pr?C[R S rcti/iKC/iG?, r ?vritE.t 1
134 73 /49.70 /49 70 \ ("n :%%(?,
i i. :r. " r,• .?.: „ i: ,, ?.r i : . /
? 3 ? . .. . . .,. i. ? , . . . ,
? .j .. ? ?.'.1' ?.- .i .. . , , .?.i•:'i'. , . ?1; ,N...?'?tr.:_?,?o
C ri If? C I ••• ? - ?
s n w c
?? ? ?? /9 r IY w2 ?i?i L iv i,y7
. ?y... -- _ Ji
v ??dMi..i.. ,..... - n
P.ar [3• .;J' ! 1 1 :4`41 i;
sRwuN '
iNTERTEC
J???:II
r
I
DR4TnM
Projec! No.- 3:2"034--"3' Clienf: +4202-}-,I`^? 54' ?LH+k i Raport No.:
Locatlan: ??"?? a? s?GC? ?3C,,^P? ~
Dmw
Waother Condifions:
Arrived On $ite Att ?' - --
Personnel Clussilippiion j Mrive Depart .
Compocfion Testiog ?
No. of Tests:
Staning Test No.: I A-
Proctor Informatian-
Svbmitted To-
Conerata Teating
Performed By:
,
Page _ os
Dote Castr Supplier. Spcc. Strengfh:
SeT: Mix: Air: Slump: Temperature:
Set! Miz: Air: Slump:.-- Tereiperuture: ?-
Set: - Mix: Air. $lump: Temperuture: ?,.
Sotr Mix: Ai? Slump: Temperature:
Set: Mix: Afr. Slumpo - Temperatvre: ?
r.........a..s?.
?
Suhmiried Te:
Parformad By: S??R?
White copy 1o Broun lirtarfec file. Blve copy ta Yroject Site ReprtsenkAeve.
Ending Test No.: ZSZ
Address: 3060 Poppler Lane Zip: 55121
Lot: 5 Block: 00 Subdivision: POPPLER HOMESTEADS
THE FOLLOWING TTEMS WERE/WERE NOT COMPLETE AT FINAL TNSPECTION ON
Yes No Comments
Final grade - 6" from sidin
Permanent steps - arage
Permanent ste s- main ent
Permanent driveway ?Q
Permanent gas 'hr
Retainin Wall or 3:1 Max Slo e
So Seeded awn
TraiUcurb dama e
Porch
Lower level finish
Deck
Fire lace
. V erify with your builder that toof test caps from the plumbing system have been removed.
• T um off water supply to the ouuide lawn faucets before freeze potenrial exists.
• Call the City s Eng'vieering DeyarGnent at 651-675-5646 prior tu working in right-of-way or installuig
arigation system.
V BUILDING INSPECTOR: ?j a,k4
CONTRACTOR:
Morningstar Homes
12845 195th Avenue NW
Elk River MN 55330
f . ?
?)f?!'t : ??????E ??rCE' t=Yo?: ?+YYix? 7?usli'
SPRAY FOAM TECH, LLC
DATA SHEET FOR HEATLOK 217-4
ALL NUMBERS ARE FROM DEMILEC USA, LLC AND CAN BE VERIFIED
BY CALLING 1-877-336-4532.
DENSITY ASTM D1622 1.7 LB/ CUBIC FT
R-VALUE ASTM C 518 R-TIN•
FLAME SPREAD ASTM E84 LS" 22 4" 22 Class I
SMOKE DEVELOPED ASTM E-84 1.5" 327 4" 404
PERM RATING ASTM E96 .93 c? 2" THICK
For any questions call :
Russ Adamski 763-350-2243
Or f f
Andy Anderson 612-859-9706
4
FYow r FARKNH Tussj
?ti ?i?"2s2 l M /I./ / Jr ? ?'
U MOISTURE
SHERWIN
WIlLIAMS.
108.17
INTERIOR LATEX
VAPOR BARRIER
B72W1
CHARACTERISTICS
Interior Latex Moisture Vapor Barrier
Primer/Finish is a coating designed to
reduce the loss of moisture through walls
and ceilings.
Moisture Vapor Barrier PrimedFinish
combines a primer and finish in a single,
fast drying coat.
Maisture Vapor Sarrier Primer/Finish
is specially formulated for manufactured
housing facilities.
Upon feld instaliation of the home, this
product can be topcoated with any
Sherwin-Williams' interior latex or alkyd
product.
Color. White
Coverage: 200 - 250 sq ft/gal
@ 6.0 - 8.0 mils wet; 1.8 - 2.4 mils dry
Drying Time @ 77°F 50% RH
(temperature and humidity dependant)
Totouch: 1 hour
To topcoat: 4 hours
Finish: 0- 10 units @ 85°
Flash Point: NIA
perm Rating: less than 1.0 perm
ASTM E96
SolvenUReducer: Water
Tinting with Blend-A-Color:
Base 0 I Stren Yh
White 'a
Vehicle Type:
Vinyl AcryliGStyrene Butadiene
VOC (less exempt solvents):
74 g/L; 0.61 Ib/gal
Volume Solids: Zs t 2%
Weight Solids: 40 t 2%
Weight per Gailon: 10.3 Ib
OTC Compliant
SPECIFICATIONS
Drywall
System 1:
1-2 cts. Moisture Vapor Barrier Primer/
Finish
System 2:
1 Ct. Moisture Vapor Barrier Primer/
Finish
2 cts. Sherwin-Williams fnterior, Latex
or Alkyd, Architectural Topcoat
APPLICATION
Do not thin. Reduction will adversely
affect the perm rating.
Apply at temperatures above 50°F.
Brush - Use nylonlpolyester brush
Roller - Use 3!8" - 3/4" nap cover
Spray - Airless
Pressure ................................2000 psi
Tip .................................... .017"-.01911
SURFACE PREPARATION
WARNINGI Removai of old paint by sand-
irtg, scraping or other means may gener-
ate dust orfumes that contain lead. Expo-
sure to lead dust or fumes may cause brain
damage or other adverse health effeds,
especially in children or pregnant women.
ConU'olling exposure to lead or other haz-
ardous substances requires the use of
proper protective equipment, such as a
properly fiUed respirator (NI OSH approved)
and proper containment and Geanup. For
more information, call the Nafional Lead
Information Center at 1-800-424-LEAD (in
US) or contad your local health authority.
Remove a!I surface conYamination by
washing with ProClean Professional@
Prep Wash Concentrated Cleaner or
other appropriate cleaner, rinse thor-
oughly and allowto dry. Scrape and sand
peeled or checked paint to a sound sur-
face. 5and glossy surfaces dull. Seal
stains from water, smoke, Ink, pencil,
grease, etc. with PrepRite@ ProBlodc@
Primer Sealer.
Drywall
Fill cracks and holes with patching paste/
spackle and sand smooth. Joint com-
pounds must be cured and sanded
smooth. Remove all sanding dust.
CLEANUP INFORMATION
Clean spills, spatters, hands and tools
immediately after use with soap and warm
water. After cleaning, flush spray equip-
ment with mineral spirits to prevent rust-
ing of the equipment. Follow
manufacturer's safety recommendations
when using minerel spirits.
1/2005 wwev.sherwin-williams.com continuetl on back
° FROM : M.T PHONE N0. : 1 AUG. 04 2005 11:64RM P3
,lq??rr : l?? FroJ*l : FavrurcA Vu ss,'
SPRAY FOAM TECH, LLC
? DATA SHEET FOR HEATLQK 217-4
A1:,.X, IVCTMF3FRS Ak2E FRUM DEMILEC USA, LLC AND CAN BE'YET21FiED
BY CALLiNG 1-877-336-4532.
DENSITY ASTM D1622 1.7 LB/ GUBIC FT
?
R-VA[,UE ASTM C 518 R-7/iN.
FI,AME SYREAT7 AS"1'M E84 1.5" 22 4" 22 C1ass T
?W
SMOKE DF.VELDPED .AS7'NI E-84 1.5" 327 4" 404
PERM RATTNCi ASTM E96 .93 a) 2" TH1CK
For any questions call :
.•:?.
Russ Adamski 763-350-2243
Or
Andy Anderson 612-859-9706
y_;
?682 10/27/23 TOUSSl, FARROKH & FARNAZ
AD VANCE SUR VEYING & ENGINEERING CO.
5300 S. Hwy. No. l Ol Minnetonka, MN 55345 Phone (952) 474 7964 Fax (952) 474 8267
suRVEY FoR: FARROKH & FARNAZ TOUSSI
IN V=867.01
SURVEYED: June, 2001
DRAFTED: June 18, 2001
\
?
1
REVISED: July 30, 2003 to show new proposed dwelling
REVISED: Aug 13, 2003 to move proposed dwelling 10' south and west to setback line. 30.0
REVISED: Aug 13, 2003 to add additional items per City of Eagan.
REVISED: Sept 23, 2003 to show changes per City of Eagan.
REVISED: Sept 29, 2003 to show grade chanaes along north property line. ?
REVISED: Oct 9, 2003 to show changes per City of Eagan. ?
LEGAL DESCRIPTION:
L
5
P
l
H
D
k
C
Mi
d ?
ot
,
er
omestea
s,
a
ota
ounty,
nnesota.
opp
?
ADDRESS:
3060 Poppler Lane, Eagan, Minnesota 55122
34 B-B
Top oi Foundation 898.9, Lowest Floor 895.9, Garage Floor 898.4
PROPOSED ELEVATIONS: II I ?y
'??
not as familiar with local codes as the local building officixl and zoning official in this communiry
are. Be surc to show this survey to thesc officials, or any other officials that may have jurisdiction
over the home and it, sitin-,,, and obtain tlieir approvals before beginning construction.
6. We have provided a benchmarl< for your use in detennining elevaYions for construcYion on this
site, use that benclimdrk and nothing else for that purpose. Check the elevation of at least one other
f'eature shown 2o verify your elevations.
LIMITAT10NS:
The scope of our services for this job is as follows: n-
1. Showing the length and direction of boundary lines of the ]egal description which you furnished.
2. Showfng the location of existing improvements we deemed important. ?
3. Setting new monuments or verifying existing monuments to mark the comers of the property. O
4. Showing existing spot elevations necessary w show elevation difFerences on the site.
5. While we show a proposed location for this home, we are not as familiar with your house plans ^
as you and your arcliitect and/or builder are. Check our proposed location and siting of the hotne 01I
and yard grades carefully to see that they match your plans before construction begins. Also, we are
Benchmark* 892.9, *Rim of manhole as shown [ 44
a
STANDARD SYMBOLS & CONVENTIONS:
"e" Denotcs 1/2" ID pipe with plastic plug bearing State License Number 9235; set, unless
otherwise noted. Proposed elevations are shown witli a box around them, while existing elevations
ate shown without a box. Arrows indicate the proposed flow of stonn water on the site.
I hereby cenify that this plan, specification, report or survey was prepured hy me or under my direct
supervision and that 1 am a licensed Professional Engineer and Professional Surveyor under the
:@t?
laws of the State o in? ???
/? )
J me H. Parker P.E. & P.S. No. 9235
1 n ?, .-,`
,
'7 . n rrq;?
i-?
? ? ? ??• n
. .,
,
t
HMARK: ?
,
qppROxiMqTE CT?CH BASIN
MANHOLE LOCATION OF -
EXISTING SEWER B? ' ,
TY CORNER
- RiM ?v.=avs.o,
.=892.9
T892.2 -
L=TDFALLS ON,EDGE O/
H
^' MAN
OLE
S 89'S5'07" (PAINT ?On
890A
2.0%
- 2.0%
--134$2 c 889.0
?
?
G
S s
?
2.0 %
- - - x 890.6
----- ?
--------------
14.2 30.0
I
I
0
O
c6
r,
w
v? .
W ao O
N? o
o: z Q
?pe o
0
3w
43N Z
A
F
30.6
------
---
? ?
8"PINE
?
I?
?
15' DRAINAGE
UTILITY EASEMENT ? ° i
PER DDC. 1384365 //11
20' ASH ?
----?-- ?--7-------?-----r--
?
?
WALK OUT I
COURT - 75.0
?-----
?,.
QRpP0?
5- 0
pR OpE
19?
mO? ___--''--
?
? xB97.3
8982
897
20 0 10 20 40
SCALE IN FEET
5
o ? X 893.7 I
55 I (
9 .4 I
n • ????{- ? w
? i 10"PWE I w
10 ?
? 10'PINE I =
I ?
I I O
? I
?
m ?
3
c ?
?--I-5.0 25.0
? fl i`10_0
1 IN I
SE7BACK (TYP.) z
a8s.5
x 890.4
3
(p O
O) P
40
?o
?o
z
x 891.5
I °
0 896.1 - ToT 892.D X I z I xe922
n ?
o ,
asz.7
--105.22-- --' s92 .7
996.4x S 89'55'49" E ' 894.0 x x1893.3
/
L or Fietaining !Alall Wig
Lor=is,saa.a so.FT. Raquired
HOUSE FOOTPRINT=3,002.6 SQ.FT. -?
COVERAGE=17.7%
Dwn. Na. 037003
? RECEIVED
OCT 10 2003
EAGNfV
ENGINEERING DEPARTME{VT
FROM : M. T
w?u?a
.
PHDNE N0. :
FYvr? ?A??QQ?'?I ?uss?
1 faUG. 04 2005 11.03AM P1
108.17
30160 fio,%LerZn
9ok??I„„f sse INTERIOR LATEX
U
MOISTURE VAPOR BARRIER
SHERW/N
VVILUAMS.
B72W1
CHARACTERISTICS
Inhvlor late: Moiswre Vapor Barrier
PrlmartFinish is a coating designed to
teduce th0loss of moisWrCthrough watls
and csilinps.
MoistuR Vapo? Ba?rier PrimeNFinish
combines a primer ar+d finish in a single,
tast drying coat
Moisture Vapor Barrier Primer/Finish
is specially fotmulatect for manufac[ured
housing facinties.
Upon field instaliatian of the home, this
prOduct can be topcoated with any
Sherwin-WilAams' iManor latex ar atkyd
product.
Color. White
Coverage: 200 - 250 sq iVgal
@ 6.0 - 8.0 mils wet; 1.8 - 2.4 mils tlry
Drying Time @ 77°F 50% RH
(temperature ana humidity dependarrt)
To touch: 1 hour
To Yopcoat 4 hours
Finish: 0- 10 units @ 85°
Flash Polnt: wA
Perm Ratlng: Iess fhan 1.0 peffn
ASTAA E96
SolveMlReducer Water
TlMing wifA 61end-A-0olor.
Base o I 'Stren th
VJhite ?
Vehicle Type:
Vinyl AcryliGStyrene Buiadiene
VOC (fess exempt sowems):
74 gn; 0.61 Ib/gal
Volume Sollds: 26* 2%
WeigM Solids: 40 t 2%
WeigM per Gallon: 10.3 Ib
OTC CompliaM
SPECIFkCATIONS
Drywali
5ystem 1:
1-2 cts. MoiSSUre Vepor Barrier PrimeN
Fnish
System 2:
1 d. Moisture VapOr Batrier Primed
FinisR
2 ds. Shsiwin-Witliems Irderior, Latax
or Alkyd, ArChiteCtural TopCOat
APPUCA710N
Do not 1hin. Reduction yYill adverseiY
aHxt the perm watittg.
Apply et tempereWres above'SU°F.
Brush - Usa nyloNpolyester bru5h
Roller - Use 3le" - 3/4" nap cover
Sptay - Airless
Ptessure ........... ..................... 2000 psi
Tip .................................... .017"419"
SURFACE PREPARATION
YIO4RNINGI Remov8l ofold peiM by San6-
ing, scraping or other means may gener-
ate dust or fumes that contain lead. Expo-
sure to lead dustatumes may rause 6rsin
damage or otlw edver52 haallh etteds,
especieElY in childran orProBnarft wamen.
canadung evoura m leaa or otner nez-
ardous substances requires the use of
proper protective equipment euch as a
AroperlYfilled respirator(NIOSM eWovedl
and proper conminment and Geanup. Fa
more Infomiadon, call the NaUOnal Lead
InfOrmetion Cenwat 1$0Q4241.fJ1D (in
US) or cwtad your ixal health authority.
Remova all surface contamination by
washirg wilh ProClean ProfeeslonaM
Prep Wash Coneentrated Cleaner or
Othef 8ppropri2tB CIEeRBt, f1n6B thar-
oughly and allow to dry. Scrapa and saM
pseled or dhedced pairrt to a saund sur-
face. Sarid glossy surtaces dull. Seal
smirvs fran water, smoke, ink, pencil,
grease. etc. with PrepRiteS Pro6lodcO
Primer Sealer.
Drywail
FiU cradcs and hWes with patching pwe(
spadcle and sand smooUi. Joint cam-
pounds must be cured and sanded
smooth. Remave all sanding dust
CLEANUP FORMATION
Clean spills, spafAers, hands and tools
enmedietely after use wilh soeP and wartn
water. after deaning, flush sprey equip-
ment wi[h minerW Spirits to preveM rust-
ing of the equipment. FoUow
manufacWrer's sataty reeammendaeions
when using minCr81 SpIrt2S.
Ir2005 www.aMnvirwwilliams.com continued on back
FROM : M.T PHONE N0. :
108.17
I NTERIOR LATEX
MOfSTURE VAPOR BARRIER
B72W 1
1 AUG. 04 2005 11:03RM P2
CAUYIONS
For interior usa only.
Proted Nom freezin9•
C,qUTIpN conbin5 CRVSTALLINE SILJG0. U9e only
xrilh a0e7uam va?laflon. To iVdd weKA=U+e.
.W WnEOws ind aoors of uae otllet moons b
enatmafteshaReMrydufin9eWICati0nam 0ryup. tf
you eocPafiGhee eye wAteAnC. hC?tleohes. or aan
ree4 inCrcaze(rec0 airorweer iesP??Y P?on
(NI0.sl/ appmved) a Ifiawme aroe. Aaequaee -
Ylalia+ reQutred rwwn sendino w e6rad'mD MeE?
flm. I(edeQwEG ven01eti0n C7nrot be Wa'i6M v.9ar
an approwe o?+? rcsviraeor ( IiIOS N eppmvtaJ.
Ftlbw ?aapitab? ^?eMR'.1ctu'ars dirocUoos for ie60h
ralor use- Awid Wtaa wwah el'es eM ekin. Wa'in
hands after uEinB. IfaeV con W ner dose0 wW not in
u9e. Oo n0l trenefef COOMM m~ CmtlsN°h? TOt
etoreqa F1w3T ND: In eme of qe eonmU. Auth
tliaaghNwitli IaroeamwNSmVIa9ar. GetmeCUxl
e(tMGOn Nirtilefion p?eids. R9wiHiwned. eall Pelpon
rantrol CmteinoePitel tmer8ency mom, or PhYw
den imm07iemy. DELAYEO EFFEGTS FROM LOHG
TERIA OVERDCPOFURE. AbedMOafsa1cft dthe
dlYflm meY rebeee CtystalUne ailied Whkc+hes Eben
shewn Sp esum lunp Aamage eeW eanW und- lan0
, tetm sxpptytB. WARNWG: THis pmduCt w^tBins
nnertecets known m tlre SWe d CalCOmia 1o tause
I? cenaranaoo-mdetsasaomarFawoduetiuenarm
' DO NOT 7AKE INTE33NALLY. KF:EP OU7 OF TtiE
RFACN OF CHILDREN. FOR PROFESSIONALUSE
pNLY.
HOTW 11/1Bf200a 872W00001 0400
7he infortnation and recornmendations
set foAh in this Produd Dafe Sheet ere
based upon tests conducted by w on
behalt of The Sherv+in-Williams Com-
parry. Such infortnation snd recommen-
dations set forlh Ierein are subject to
chenge and pertain to the produd offered
at the Uma of publication. Consult your
Shetwin-Williartl5 reple50Meliv2 M obbin
the most recent Ptvdud DBRt SheCi.
FROM : M.T PHONE N0. : 1 RUG. 04 2005 11:04AM P3
,A P441l?'e ie5hCe r'Yowr : FaYruxA 7au ss? SPRAY FOAM TECH, LLC
? DATA SHEET FOR HEATLOK 217-4
AI..I, NY7M13E12S A,12E FRUM DEMILEC USA, LLC AND CAN RE VEY2IFIED
BY CALLI1lG 1-877-336-4532.
DENSITY ASTM D1622 1.7 LB/ CUBIC FT
'
R-VALITE ASTM C 518 R-7/iN.
FLAME SPREP,D AS"1'M E84 __
1_5" ?? 4" 22 C1ass Y
SMC7KE DF.VEI.OPED ASTM E-84 1.5" 327 4" 404
PERM RATINCir AS'1'M E96 .93 (7 2" T'141CK
Fvr any questions call :
Russ Adamski 763-350-2243
Or
Andy Anderson 612-859-9706
?;
PERMIT
City of Eagan Permit Type:Mechanical
Permit Number:EA164262
Date Issued:09/24/2020
Permit Category:ePermit
Site Address: 3060 Poppler Lane
Lot:5 Block: 0 Addition: Poppler Homesteads
PID:10-58400-00-050
Use:
Description:
Sub Type:Residential
Work Type:Replace
Description:Furnace & Air Conditioner
Comments:Carbon monoxide detectors are required within 10 feet of all sleeping room openings in residential homes (Minnesota State
Building Code).
Questions regarding electrical permit requirements should be directed to State Electrical Inspector, Mark Anderson at (952)
Fee Summary:ME - Permit Fee (Replacements)$59.00 0801.4088
Surcharge-Fixed $1.00 9001.2195
$60.00 Total:
I hereby acknowledge that I have read this application and state that the information is correct and agree to comply with all applicable State
of Minnesota Statutes and City of Eagan Ordinances.
Contractor:Owner:- Applicant -
Farrokh M Toussi
3060 Poppler Lane
Eagan MN 55121
(612) 707-2442
Sedgwick Heating & Air Conditioning
1408 Northland Drive, Suite 310
Mendota Heights MN 55120
(952) 881-9000
Applicant/Permitee: Signature Issued By: Signature