.,?.,...z??,CODEINVESTIGATION:? ?..,?s,?
T-360 Eagan, P.C. 1352
Cliff Road at Rahn Road
Eagan, Minnesota
Camnission No. 9088.801.33
Issued: 15 taarch 1988
Reissued: 31 xarch 1988
„>e::.
.:. a<c .. . .. ..., ?` zz:;.u°£s??x?r%r:.o:? . a?s ..?. ? ?•n:.o??.>:z-.:i'.::z::?ow;::;;s33:v°%??z,s?,s..°°,.?. :?,8u • ?:?, ,?...y?.r. z„vr'K:?' u*.( :'?S`>? .nb?
?,.<i???:?..?•CODES ?:?.°}'?3.Y.bw..'...?..a.9. ........,.?i?w?.sEi.cY??nw? n'..?r.:ro'.v"?`?'?'.`..:`...'6iNi;.ryH"?°FZ°Sa.,,?wtna.?s£`,:'d1ra•,,.=o-?"«:`i:v..ur'.''r.r.a&»i........?<aoa
LSH?3.???'???...???c?o'"','u,°:>"!??>. '... rA?w:.u3S?r~«,,,A,'"?.tZ"......Y..'.?....sr.e
DIVISIQN I GIIVERAI. - Uniform Building Code, 1985 Edition (85 UBC)
- Minnesota State Building Code, 1985 Fdition (85 MSBC)
DIVISIdN II HUIDICAPPF.D ACCESSIBILITY - Minnesota State Building Code, 1987 Fdition, Chapter 1390;
Facilities for the Handicapped (87 M5HC)
DIVISICN III SPRUC1LIItAL - Uniform Building Code, 1985 Edition (85 UBC)
- Minnesota State Buildinq Code, 1985 Edition (85 MSBC)
DIVISION IV I+E(MIICAL - tJniform Mechanical Code, 1985 Fdition (85 UMC)
- Minnesota State Building Code, 1987 Edition, Chapter 1345,
HVAC Code (87 t4SBC)
DIVISICN V PL[MIIVG - Department of Health, Minnesota State Pltnabinq Code, Chapter 4715,
1987 Edition (87 MSPC)
DIVISIQR VI FIRE PRL71'SC'1'ICN - Unifocm Fire Code, 1982 Edition (82 UFC)
- Minnesota State Building Code, 1986 Edition, Chapter 7510,
Fire Safety (86 MSFC)
DIVISIQN VII E•E`T+TQw - National Electrical Code, 1987 Edition (87 NEC)
- Minnesota State Building Code, 1987 Edition, Chapter 1315,
Electrical Code (87 MSEC)
DIVISIQd VIII REAL7H RE7G7LATiQNS - Minnesota State Health Department Regulations, Chapter 4625,
Food and Beverage Regulations
DIVISIQd IR ENERGY - Model Energy Code, 1983 Edition (83 MEC)
- Minnesota Energy Code, 1985 Edition, Chapters 1325 and 4215 (85 MSEC)
m m m m m m m i¦¦i m ? s m m m mm r m ^
m m m m m m m m m m m m m ? ! m W m m
DIRHCiaRY
Ea9a[?. 19innesotd
Building Official Doug
Stev
Address City
Plwnbing Official Bill
Address CitY
Jerr
Address Minn
Mechanical OfEicial
Address
Electrical Official Bill
Address CitY
Fire Department Dale
Address Eaga
s Fire Marshal Phone (612) 954-8100
Dirk House Phone (612) 454-5100
Phone
Health inspector Dave Goff, Public Health Sani
Address Minnesota State Health Depart
Public Works Tom
Address CitY
Planning Department Dale
Address CitY
Others (List):
Address
Phone (612) 489-9009
Fire
Phone (612) 454-8100
N¢V 55122
Colbert - Director, Ed Kirscht
- Citv Planner, Jim Sterm
Phone (612) 959-8100
Phone
Phone (612) 623-5390
is, tMI 55440
Phone (612) 454-8100
Phone
Address
? mm m m MW m m mmmr mmi mmm
PE[tlQT P%)CEI[IItE CmXZSST
Fa9an. Minitesota
TOPICS gpQ7IgEMENTS gFMARRs
1. DOCUMENT SUBMISSION ( x) Complete set of working drawings:
2 copies
( R) Site Plan: 2 copies
( x) Parking Analysis: 1 copy aai Site Plan
( R ) Specifications: 1 copy
( x) Snack Bar Equipment Plan: 1 copy
( ) Structural Calculations
( R) Energy Calculations Building Hrvelape and
6eat Loss Calculations
( ) Ehqineering Calculations
( x) Sprinkler Shop Drawings - Sprinkler Subcoo-
tractor to suhmit 5 copies for review by City
! ) Other:
2. PROFESSIONAL CERTIFZCATION ( R) Certification Statement and Signature of P?/E
Consultant
( ) Affidavit of Code Compliance to be prwided
by A/E Consultant
( ) Affidavit of Code Compliance to be prwided
by others
( ) other:
3. PLAN REVIEW ( x) Architectural
( R ) Structural
( R ) Mechanical
( % ) Electrical
( ) other:
Page 1 of 3
PEIaQT PROC'MM QRECIQ,IST
Edga[I, M1flilCSOta
TOPICS REQiJIREMEN'PS REMARRS
i R) By euilding Inspection Department
( ) By Design Review Board
( % ) By Others: Planninq Department
Minnesota State Health Department reviews
Snack Bai Plans. 1hiS review dceS not have
to take glace before 6uildinq permit is
issued.
9. CONSTRUCTIOlV PHASE ( ) Inspections to be performed by A/E
Consultant
( ) Inspections to be perfoimed by City
( ) On Site Observation by A/E Consultant
( ) On Site Observation by Others:
( R) Review of Plan Revisions by Building
Inspection Department
( ) Review of Plan Revisions by Design Review
Board
( R) Other: Site Plan revisions by Planning Dept,
5. FORMS AND GUIDELINES ( R) Building Permit Application Fonq/Instzuctions City of Eagan 1988
Buildinq Pecmit Applica-
tiat
( R) Snack Bar Permit Application Form/Instructions
Foc Minnesota State Health Department Review
submit two sets which include:
A1, 3/32^ Floor Plan
A5, 1/4" FlaOt Plan
A10, Schedules
I92. 3/32" Pltmbing Plan
146. 1/4° Plumbing Plan
Snack BaL Fquipment Plans (by Byczek)
Page 2 of 3.
m m m m r m m m r ? ? ? ? ? ? m im m ?
m r m mm m m mr
PFMQT PAO(EDURE CHECiQ.IST
Fagan. Miimesota
TUPICS REQIJIRIIMENTS gpMAM
( x) Building inspection Application Focros/ Inspectians required for
Instructions dwellings, multiple
dwellings azrl commer-
cial/industrial bldgs.
( R) Fee Schedule 1988 pecmit fees and
licensing reqiurements
( ) Plan Review Checklist
( ) Other:
Page 3 of 3.
? WiviM I "OneMP M W M M r ? M M. M M ? W M ?
[NIFM B7ILDIING CtiDE, 1985 Edition (85 (mC)
!@MMPA STATE BOILDING OODE, 1985 EDITION (85 MSBC)
SR
1VPICS REQUIREMQVTS SECTIONS RII4ARRS
1. PERMZTS AND INSPECTICNS UBC Section 305 (E) amended to See 85 UBC Chapter See outline receided
require the following on-site 3 and 85 MSBC, fram City of Fagan
inspections: Administration for required inspections
1. Footing/foundation Section
2. Concrete slab
3. Frame inspection
4. Insulation inspection
5. Lath and/or gypsum board
inspection
6. Final inspection
2. OCCUPANCY CLASSIEICATIM
A. Retail Sales, Office & B-2 701, pg 47 O1C
Support Areas (Sales) Table 5 A, pg 37
3. FIRE DISTRICT CLASSIFICATIOAI Prescribed by local juris- Not addressed in No fire districts
diction UBC or MSBC
4. TYPE OF CODiSTRUCTION II-N 1901, pg 99 Sprinklered
5. ALI.OKABLE HEICHT 2 stories, 551-0" maximim Table 5-D, pq 42 1 story,
261-6" at highest
point of parapet
(, ar.rrxaaar.F FLppg ARFA Unlimited Floor Area with 506(b), pg 32 114,232 sf footprint
apprwed sprinkler system and +3,500 sf inezzanine
601-0" min. public ways or yards = 117,732 sf actual
on all sides area
euilding Dept. will
accept unlimited area
cwntingent on yard
agreement
T-360 Division 2
Paqe 1 of 14
Division i - General
iWIFOIt?! HiTILDIIM (ODE. 1985 Editiaai (85 UBC)
KMMM STATE B[IILDDIG dODE, 1985 EDITICbi (85 ASBC)
SR
R+DPICS REQiJIRIIMENTS SEGTIaNS gEMpRKg
Fire separation is
601-0" oc greater, on
three sides with
abutting shoppinq
center on fourth side
7. FIRE RESISTIVE REQUIgpKENT5 Foi Type II-N
A. Extecior Bearing Walls No requirements Table 17 A. pq 89
Non-combustible
B. Interior Bearing Walls No requirements Table 17-A, pq 89
C. Exterior Non-bearing Walls No requirements Table 17-A, pg 89
D. Structural Frame Non-combustible Table 17 A, pq 89
E. Partitions - Pecmanent Non-combustible, or 1705(b), pq 78
Non-Bearing pressure-treated fire- 1901, pg 99
retardant wood
F. Shaft Enclosures Non-comtnistible 1706(a), Exceptions
1 and 5, pg 80
G. Floor Construction Non-combustible, Table 17-A, pq 89
1904, pg 100
H. Roof Construction Non-combustible Table 17 A, pq 89
1906, pq 100
T-360
Sprinkleced
OK
Division I
Page 2 of 14
m i m mm mr m m mm m m M` m aft ? m
? MPivWW IMpne? ? ? ? ? M go M r ? M M
INRFOM &JILDM CODE, 1985 Edition (85 iIDC)
MII3N[ESO'1k STATE B[TILD= OODE, 1985 EDITI(N (85 17SBC)
SR
TOPICS REQUIREMEN'p5 SECTIONS gMipM
1. Exterior poors and Not permitted less than 51-0" Table SA, pg 37
Windows from coimaon property line;
protected less than 101-0" from
property line
J. Roof Covering Fire retardant 3202(b), pg 538
K. Fxit Access
1. Stairaays No fire-rated enclosure 1905, pq 100
zeNlred 3309(a), Exception
1, pg 566
2. Corridors No fire-rated enclosure 3305(g), FSCCeption
required when occupant load is 5, pg 562
less than 100, fully sprinklered
and smoke detectors installed
L. Interior Wall and Ceiling
Materials less than 1/28" in
thickness shall have flame
spread characteristics no
greater than paper and shall
be cemented to non-
combustible backing.
4201, pg 608
T-360
Verify if door by
Grids 2 and 11 can
occur in location
shown. Acceptable
location cattingent
ai yard agreement.
Class 'B' provided
09 - Not enclosed (see
Architectural Checklist)
Office mezzanine has
occupancy of less than
100 and is sprinklered
throughout
Corridor does not have
to be rated if smoke
detectors are installed,
Prwided
Division I
Page 3 of 14
bivision I - General
[S1IFOW BMIaING oODE. 1985 Edition (85 UHC)
MIfP1FS0"lA 51'ATE BuILDIIVG OODE, 1985 EDITIQN (85 MSHC)
SR
'1OPICS REQUIRE:MENTS SECTIONS RII4ARRS
Finish material greater than
1/28" thick shall meet the
following flame spread
classifications:
8. OCCUPANCY SEPARATION
Rooms or Areas - Class TII
Enclosed Vertical Exit Ways
(if any) - Class Ii;
Other Exit Ways - Class III
when sprinklered
A. Target/Adjacent Building Unlimited Area, 601-0" yards
No Connection around entire complex of
connected buildings, fully
sprinklered, same constzuction
type. = No requirements.
S. Retail Sales/Storage
for Sales
62/B2 = No requirements
C. Retail Sales/Office
T-360
B2/B2 = No requireraents
9201, pg 608 Kydex is a Class II
material
4204, Table 92-8, Provided
pq 610
4204(a), Exception Sprinklered
2, pg 609
One-hOUr separation re-
quired between Target
and shopping center.
RSP/SLL will send detail
of wall system for
Buildinq Dept. approval
as a ane-hour wall.
702(b), Exception, Sprinklered (See
pg 48 Architectural Checklist)
OK
Table SB, pg 40 Lounge/Training Room
is considered part of
administrative and
clerical office
occupancy. - pR
Division I
Paqe 4 of 14
r m w m m m m m ? m " m ? " " m " m m
? WRiviSM I "kneMP = M M = r
tAdiFOM BiJILDDIG CODE, 1985 Fdition (85 MC)
PMqESOTA SnTE Hi1ILDING CODE, 1985 IDITICii (85 I+iSHC)
SR
TOPICS RFMIRF.MENTS SECTIIXNS REMARRS
D. Retail Sales/Snack Bac B2/B2 = No requirements Table SB, pg 40 OR
9. OCCf7PANCY IAAD pR
A. Main Level
1. Sales 83,077 sf Table 33-A,pq 582 Rms #101,102,119,150,151
30 sf/occ
2. Offices 720 sf
100 sfJocc
3. Storage/Stock 25,199 sf
300 sf/occ
= 2,769 occ
= S occ
= 84 occ
9. Snack Bar
Food Preparation/Serv. 565 sf
200 sf/occ = 3 occ
Seating 836 sf with
48 fixed seats = 48 occ
5. Mechanical Equipment 781 sf
300 sf/occ = 3 occ
6. Accessory Spaces Areas ordinarily used by
persons who occupy the main
areas of an occupancy need not
be included in the total occupant
T-360
Table 33-A, pg 582 lbns #103, 108, 123,
124, 125, 126, 127
Table 33-A, pg 582 Rms #113,118,121,
122, 133, 134, 135
136, 137, 138, 152
Table 33 A, pg 582 Rms A114, 115
Table 33-A, pg 582 Rm #116
Table 33 A, pg. 582 Rms #104, 120, 140
3302(a), Exception
pg 555
Rms #100, 105, 106, 107,
109, 110, ill, 112, 128,
129, 130, 131, 131A, 132
(Circulation, vestibule,
Division I
Page 5 of 14
Division I - General
INIPOM BUILDIIC OODE, 1985 Fdition (85 UBC)
m@IIwSO'1'A STATE HtTILDDG CODE. 1985 FDITICN (85 PISBC)
SR
TOPICS REQUIREPlEPPPS SECTIONS REMARK5
load of the building. Required restrooms, etc., areas)
exits from the accessory areas Each areas exiting
must be prwided for fully requirements met.
occupied areas
7. Totdl Occupancy/
Main Level (114,232 sf) =2,915 occ
S. Mezzanine Level
1. Offices 1,326 sf
100 sf/occ = 19 occ
2. Lounge/Training
3. Accessory Spaces
4. Total Occupancy/
Mezzanine (3,500 sf)
C. Total Occupancy/
Both Levels (117,732 sf)
T-360
Tahle 33 A, pg 582 Rms #201, 202, 204, 205,
206, 207, 208, 210, 211,
212
938 sf Table 33-A, pg 582
15 sf/occ = 63 occ
Required exits from each space 3302(a), Exception
are provided. The occupant pg 555
loads of accessocy spaces are
not applied to total occupant
load (see accessory spaces,
main level)
= 77 occ
=2,992 occ
Rm #203, occupant load
must be posted.
3302(c), pg 556
Rms #200, 209, 213, 214,
Stair A, Stair B
Division I
Page 6 of 14
? ? ? ? ? ? ? ? ? ? ? ? ? ? ? =so m m
? =Xivi? I M*nei r l? ? ? ? ? ?
U4IPCRi HUILDING CME, 1985 Editiat (85 UBC)
!II[OO90'lA SrA1E BUIi.DING CODE, 1985 mITIQ1 (85 liSBC)
SR
70PICS REQ[]IRIIMEN!'S SEGTICN$ MAR$
10. IXIT xEQ[nxEMDrrs
A. Ivumber 4 exits min. 3303(a), pq 557 9 exits provided - OR
B. Total Width 59.84' min. 3303(b), pg 557 601-0" for qeneral
(50 xc per 1 ft. exit width) exiting provided
50 occupants plus 31-0" for
marking and
receiving.
631-0" total - Ott
C. Arranqement Reasonable distance apart 3303(c), pg 557 OR
when three or more required
D. Distance to Exit 2001-0" with approved 3303(d), pq 557 2001-0" max. provided.
sprinkler system EV].ly sprinkleced.- OR
E. Doors
OR
1. Width 36" min., 48" max, leaf 3304(e)(f), pg 559 36" min., 48" max,
width prwided
2. Heiqht 61-8" min. 3309(e), pg 559 71-0" min., V-S"
max. prwided
3. Capacity 50 persons/foot of exit 3303(b), pg 557
width
4. Guide Rails Required on swing side of 3304(g), pg 559 Prwided
power-operated doocs used
by public unless protected
by M*all, etc. Rails to
be at least 30" high with
T-360 Division I
Page 7 of 14
Division I - General
[IIdIFO[tl4 BuIIDIIM CODE, 1985 Editiai (85 [mC)
MINNESOT& STATE HUILDIIVG CODE, 1985 IDITIQN (85 MSBC)
SR
TOPICS REQUIREMENTS SECfICJS RFMARKS
solid or mesh panels and to
project a distance not less
than widest door leaf
F. Through Adjoining or Exits from a room may open 3303(e), pq 558 Exit lights required.
Accessory Areas into an adjoining or inter- gxits throuyh back and
vening room or area prwided side stockroams not
such adjoining room is =eqLired to be ra{ed
accessocy to the area, and corridor.
prwides a clearly marked, Building Dept. may re-
direct means of egress to quire that floor strip-
an exterior exit ing be added later if
durittg their inspections
they see that rnrridor
is blocked.
11. STAIR RE($JIREKMTS
A. Width 94" min. for occupant load 3306(b), pq 563 44" min. prwided - OR
of more than 50
B. Rise 4" min., 7" max. 3306(c), pq 563 7" max, provided
C. Run 11" min. 3306(c), pg 563 11" provided
D. Landings Required when vertical rise 3306(g)(i), pg 563 Verify that landing
more than 121-0". Dimension of stair in center
measured in the direction of back is acceptable
travel shall equal the width 44" laKlinq with three
of staiLway. (Required max. 11" treads acceptable.
of 94" for stairs with
straight run)
T-360
Division Z
Page 8 of 14
? ? ? ? ? mm Mon ` ? man mmmm mm
? OftivAM I MneW M M M
[1QIFM B[JILDIIG OmE, 1985 0ditiaat (85 UBC)
MURF-W7'A SrA7.E HUILDIPIG ODDE, 1985 F.DITIaN (SS MSBC)
SR
'POPICS RE(x1IREMENT$ SECTICY9S RFMARRS
E. Guardrails Requited for changes in floor 1711, pg 82
elevation more than 30"
42" minimum heiqht
Intermediate rails required.
Spaced to prohibit the passage
of a 6" sphere (or 12" sphere
in areas not used by public)
F. Handrails Required on both sides the full 3306(j), pg 564
length of stairs; at least 1711, pg 82
one handrail shall extend
min. 6" beyond the top and
bottom risers and have ends
returned.
T-360
cuardrails that
prohibit passaqe of
6" sphere provided
in areas used by
the public
Intecmediate rails
that prohibit passage
of 6" sphere prwided
in areas used by the
public
Division I
Page 9 of 14
Division I - General
t1NIFM HUILDIIVG OODE, 1985 Editian (85 UBC)
MIIM.SOTA S"IIM BUILDIIdG OODE, 1985 miTIatd (85 IsSBC)
TOPICS RDQUIREMENTS SECTIONS RFIMARKg
- 1-1/2" min. clear to wall
- 1-1/4" min., 2" max. cross
section
- 30"-34" above nosing of
treads
- Intermediate rails in open
guardrails to be less than
6" clear (or 12" clear in
areas not used by public)
12. MEZZANINE RF7(g7IREMEDI'PS
A. Size Max. 33-1/3% of the total 1716(3), pg 87
floor area of that room
B. Exits 2 stairways required 1716(5), pg 88
C. Enclosure Non-combustible constzuction; 1716(1), (4)
need not be open to the story Exception 2, pg
in which it occurs 86
13. CORRIDOR RE'QiIIREMENTS
A. Width
B. Heiqht
C. Projections
44" min. for 10 or more
occupants
71-0" clear min.
Handrails and doors when
fully opened shall not reduce
required width by more than
7". Doors in any position
3305(b), pg 561
3305(c), pg 561
3305(d), Exception,
pg 561
T-360
OR
Actual size 3.5% of
total area; not open to
stozy it occurs in
2 provided
OR
44" min, provided
8'-0" prwided
Division I
Page 10 of 14
mrr m mr ? ? ? ? #MMMMMMMMr M
? MiviswI w&ne? M M M
tRilBtTILDnHG QODE, 1985 Sdition (85 UBC)
MIItWMfA STATE H[JILDII9G CODE, 1985 F,DITIQI (85 lSHC)
SR
DOPICS RDQUIRFMEN15 SECTIOTIS REMARKS
shall not reduce the
required width by more than
1/2. Other nonstructural
projections may project into
required width 1-1/2" on
each side.
D. Dedd End 201-0" max.
14. SPRINRLERS Required for area to be un-
limited, shall comply with
Chapter 38
15. ROOF ACCESS Buildings with any heatinq or
air conditioning equipment in-
stalled an roof require access
by stairway that meets the
followinq:
Max. Angle of Stair = 60 deg.
Treads = 6" wide and 24" long
Riser = 9" max.
Handrails both sides
Opening to roof must be at
least 9 sf with min. dimen-
sion of 21
16. SANITATIoN Fixture requirements based on
occupant load
3305(e), pg 561
506(b), pg 32
Chapter 38, pg 596
No dead end corridor
is greater than
20'-0"
T-360
Prwided with
sprinkler system
throughwt
SS MSBC Roof access prwided
1305.1750, Sect. 514 via ship's ladder
from mezzanine through
siderrall access hatch
85 rtssC
1305.1795, Table 5E
Division I
Page 11 of 14
bivision I - General
[IDiIEUt2I BUIIaD16 CnDE, 1995 Editian (85 UBC)
MII3ES0'IIk STA7'E BOILDING QODE, 1985 IDITICN (85 lLSBC)
SR
10PICS REQUIRIIRSITS SECTIOTIS RQMARKg
Sales/Office:
89,030 sf - 200 sf/occ = 945 occ.
Warehouse:
25,149 sf r 500 sf/occ = 50 occ.
Fixture Count:
water Closets
Urinals
Lavatories
Drinking Fountains
Service Receptacles
Req'd Prwided
16 10
-* 3
17 12
9 4
2 2
* Urinals can ceplace up to 1/3 of required
water closets
T-360
Request that the
required number of
water closets and
urinals be reduced
to the number
prwided
RSP/SLL to send Building
Dept. info about
Target's typical hourly
transactians for occtr
pancy. They will review
to deteimi.ne if rnmber
of fixtures provided is
adequate.
Division I
Page 12 of 14
? ? ?. ? .i¦? ? .? ? ?. ? ? ? ? r r ?rr wr? r ?
? mivAmI wanem = m r M
[]NIFORM B[TIIaI23G CODE, 1985 Editiai (85 iIDC)
MIINNESOM STATE &7ILDING CbDE, 1985 IDITIQN (85 1lSBC)
SR
'POPICS REQUIREMENTg gQMARKg
17. ARCHITEC'PORAL CEECItLIST
A. Rear wall of sales (wall
comon to sales and
stock/marking)
B. Corridor 132 and corridor
through side stock
C. Traffic vinyl doors at
rear wall of sales
D. Type of door hardware
( S ) No requirement
( ) Required as hour construction
( x) Not required as exit corridors
( ) Required as exit corridors
( R) Acceptable as double acting vinyl
doors as long as they meet flame
spread
( ) Special requicements
( R) No special requirements at man door,
at truck dock
( ) Special requirements
E. Stair A or B- Enclosure ( x) No enclosure requirement (Sec. 3301(a) )
requirement ( j Enclosure required - verify any
special requirements
F. Circulation 200 - Enclosure ( x) No enclosure requirement (Sec. 3305(g) )
requireroent ( ) Enclosure required - verify any
special requirevents
G. Lounge/Training Room 203
T-360
( x ) No enclosure requirement
( ).Enclosuce required - verify any
special requirements
See Div. II, handicapped
accessibility for require-
ments for tactile hardware.
Division i
Page 13 of 14
Division i - General
UEIPCJF44 B[TILDZNG CODE, 1985 Edition (85 USC)
MINNESOTA STATE BUILDING QODE, 1985 IDITION (85 17SBC)
SR
TOPICS gEQUjREMENTS
R
H. Local Aqencies ( ) No additional requirements by local
aqencies
( x) Additional requirements by Metropolitan
Waste Commission (contractor W handle
review)
2. Termite Control
J. Local Requirements
K. Security Platform
L. Toilet Fixture Count
T-360
( X ) Not required
( ) Required
( R ) No additional requirements
( ) Additional requirements
( R ) Wood framing acceptable
( ) Light-gauge steel framing with fire
retardant floor required
( ) Acceptable as shown
( ) Meet 85 MSBC, Table 5E requirements
City of Eaqan will review
Target's occupancy based on
average hourly transactions
to determine rnmber oE
fixtures required,
Division I
Page 19 of 14
m s m m .? ? m m .i. m m r i m m m ? ,rr m
m m ? m m m m wr m m m m m r onr m ? m r
Division II - Handicapped Accessibility
MMMMO'II°i STATE BUILDING CODE, 1987 mITiQ4, c3AP'tER 1390, FAGILITIFS Fm '1ffi ffifAIDICAPPED (87 MSHC)
SR
RnPICS REQUIRII'E1TS SECfIONS REMARRS
1. BUZLDING ACCESSIBILITY
A. Access
Required for primary flooc
Access provided to Main
Level only - OK
Access to Mezzanine
Not required for building
two stories or less which
have an occupant load of
less than 100 persons on
mezzanines other than floor
of building access
1390.0300, Suhp 4,
Exception 2, pg 167
B. Appcoaches Access to building entrances 1340.0300, Suhp 2,
shall be by walks. walks pg 166-167
shall be concrete ... with
slip-resistant surface, not
less than 48" wi.de, with
slope not to exceed 1 to 20.
C. Entrances Minimum of one primary 1340.0300, Subp 3,
entrance - accessible. Must pg 167
be identified for that use.
D. Parking One parking space pes 50 1340.0300, Subp S,
spaces shall be proposed foc pg 167
use by handicapped;
identified for that use.
Min. width of handicap
parking space - 12 ft.
Locate near to accessible
entry.
T-360
OR
Sidevmlk ramp with curb
cuts provided - OR
One provided - OlC
Parkinq will be shown on
civil drawinq - Cg
Divisian II
Page 1 of 4
Division II - Handicapped Accessibility
MINNESM STA1E 6[TILDING ODDE, 1987 EoITIaN, cRIpTIIt 1340, FACILITIES FOfft THE gMIDICAppED (87 MSEIC)
cR
TOPICS REQUIREMENTS SECTIONS gEMARgg
E. Door. Doorway and 31" min. cleat width in 1340.0300, Subp 6.A, 09 - 32" minimum
Thresholds open position. py 157 prwided
Thresholds shall not exceed 1340.0300, Subp 6.B, 1/2" max. provided
1/2" pg 167
Floor or landing at least 3304(h), pg 560
49" long required on each
side of door
F. Vestibule
7' must separate two sets
of doors in a vestibule
1340.0300, Subp S.D,
pg 167
1340.0300, Subp 6.B,
pg 167
OK - Provided
G. Door Hardware
H. Corridor Width
1. Aisles/Lanes
J. Checkout Lanes
T-36U
Door shall be operable by
a single effort with one
hand
Not addressed in UBC
where aisles or lanes are
defined with directional
barriers, rails ...
merchandise ... at least
one shall be not less than
31" clear for use of
handicapped
Not addressed hy MSHC
3315(b) 2, pg 572
1340.0300, Subp 8,
pg 168
OK
OR
7Wo 36" checkout
lanes provided. Should
be identified with
sicg?aqe.
Division II
Page 2 of 4
r ? ? ? ? ? ? m im ?M= mmm m mmm
? i¦n m m m r m M M m m m m m m r m m m
Division II - Handicapped Accessibility
lIIDIIOSORA SiT1E B[1ILDING ODDE, 1987 FDITIQV, aMPTffit 1340. FACILITiES FOfft THE ffiMICAPPEU (87 MW)
SR
TOPICS gDQUIgEMENTS SECTIONS ggMARKs
K
L.
M.
N.
Sanitation Accessible toilet facilities
that meet the requirements
of Section 1340.0500 shall
be provided on all accessible
floors. For buildinqs having
more than one toilet room for
each sex, at least two shall
comply with 1340.0500.
Telephone Where public telephones are
provided, min, of 1 shall
have handset, dial, and coin
receiver within 54" of floor.
Unobstnacted access at least
30" wide to be provided within
12" of telephone.
Drinking Frnmtain
Etiaergency Alacros
Where water fountains are
pravided, min. of 1 shall
have spout within 33" of
floor and upfront, hand-
operated controls. Alcove,
if any, shall be min. 32"
wide.
Not addressed hy MSHC
1340.0500, Subp 1, 2,
aznd 3, pg 168-169
511(d), pq 36
511(c), pg 36
0. Controls The top of controls for 1340.0800,
thermostats, manual fire pg 170
alarms, and similac equip-
ment shall be no higher
than 5' above floor.
T-360
2 for each sex
provided - OR
Provided by Owner
OR
1 prwided
OK
No requirements.
OR
Division II
Page 3 of 4
Division II - Handicapped Accessibility
KUMESOTA S'1'ATE HtJILDIIM CME. 1987 IDITICN, CmPrIIt 1340, FACILITtffi EuR T9E
(87 MSEIC)
TOPICS REQUIRENENPS SECTIONS RFMARI($
P. Signage Not addressed hy MSHC prwided by Owner
0. Tactile Identification Spaces normally used by the 1340.9000, Subp 1, See Architectural
qeneral public shall have pg 171 Checklist, Div. I
tactile identification. Spaces requiring tao-
Tactile identification shall tile identification will
be raised or recessed letter, be determined as part of
labels or plaques; maunted plan review
at 9-1/2' to 5-1/2, above
the floor, adjacent to the
space identified on the side
nearest the door handle.
Door to stairs other than 1340.9000, Subp 4, Riwrled hazdles required
exit stairs, loading plat- pg 171 oai doors to Mech. and
forms, boiler rooms, and Elec. itooos, Ccapactor.
doors serving other
hazardous locations shall Mrninq stripe in floor-
have knurled or similarly ing acceptable at stairs
marked door handles.
R. Fitting Rooms Not addressed by MSHC 2Wo accessible fitting
rooms provided - OR
T-360 Division II
Page 4 of 4
m rw mm m mr m No smrmmmimmr
? viSion II Structural
INIEM B[JILDING QODE, 1985 Edition (85 UBC)
PONNESOmk STATE 6UILDIIVG CODE, 1985 Editian (85 175BC)
'1t7P2CS REQUIREMENTS SECfI0A15 ' gEMAR[(S
1. FLOOR DESIQV
A. Office Mezzanine Live Load SO psf plus 20 sf 2304 108
P
partition load
2. ROOF DESIIN
A. Roof Live Load
Minimum - 20 psf with
allowable reductions
B. Snow Load
C. Water Accumulation
D. Roof Member Deflection
3. WINp DESIGN
A. Wind Pressure
T-360
As prescribed by local
jurisdiction:
( ) D psf
( ) 10 psf
( ) 20 psf
! 1 30 psf
( X ) 40 psf
( X ) Occasional pondinq of
water
( ) Positive Drainage
, pg & Desiqned for 50 psf - 09
Table 23-A, pg 124, LL plus 20 psf
2306, pg 110 part. load (DL)
Includin4 Lam9e/
Training
2305(a), pg 109 & Designed for 40 psf
Table 23-C, pq 128 09
2305(d), pg 109
Designed for
( ) 0 psf
( ) 20 psf
( ) 30 psf
( X ) 40 psf
OR
2305(f), pg 110
Flat roof with internal
roof drains & overflow
scuppers - IXC
Max. L/240 Live Load Defl. 2307, pg 111 & Desiqned for LL
Table 23-D, pg 129 Defl = L/240 - OK
Sasic wind speed =( X) 80 mph 2311, pg 112 & Designed for 80 mph
( ) other; Figure No. 4, Exposure C- OdC
_ mph pg 137
Division III
Page 1 of 2
Division iSI - Structural
[ANiFM B[TILDING CODE. 1985 Editi(m (85 UBC)
KHOZSOmk STATE BUILDING OODE, 1985 Fditian (85 PISHC)
SR
TOPICS gEOMgEMENTs
SECTIOqJS' gEMARKg
4. PARTITIODI DESIGN 5 psf Lateral Load 2309(b), pg 112 OR
5. ANCHORAGE OF CODICRETE pR Positive direct connection 2310, pg 112 OK
MASONRY iULLS between walls and floor and
coof to develop a minimm
horizontal force of 200# per
lineal foot
6. EAR'LZIQUARE REG[JLATIOZVS
7. FOUNpATI0N INVESTICdATIOAI
8. FOOTINGS & FOUNDATIOAIS
T-360
m m m m m m m
Building located in seismic 2312, pg 114
Zone No:
( ) 0, No Damage
( X ) 1, Minor Damage
( ) 2, Moderate Damaqe
( ) 3, Major Damage
( ) 4, Major Damage, Proximity
of Major Fault System
Soil irrvestigation has been 2905(a-f), pg 522
made by licensed soil testing
laboratory
Recoffinended fovndation type
by soil consultant is:
( X ) Spread Footings
( ) Drilled Piers
( ) Piles
Allowable foundation pressure 2906, pg 523
is 4,000 psf
Designed for Zone 0,
Earthquake. Require-
ments are not enforced
under Minn. State Bldg.
Code. - OR
OK
Footinqs to extend below 2907(a), pg 523 Footings to extend
frost line. Maximim 42 inches below
depth is 42 inches finished qrade
Division III
Page 2 of 2
m
? EftivMn IrMecWKcaAM M M M M M M M M M M M M M
lmREso'PH STATE BUILDIIVG OODE, 1987 mITiON
G'EII4PTER 1345, HVAC OME (87 MSBC )
SR
7i0PICS REQiJIRDMENTS SECTIODIS REMARKS
1. APPLICATIOTI FOR PERMIT
A. Plans & Specifications
2. EQIIIPMENT - GIINE,'RAL
A. Fuel Connections
Plans and specifications
to the administrative authority
as required
A manual main shut-off valve
shall be provided ahead of all
controls
1345.0120, pg 5
1345.2250, pg 144
mlhmit energy calcula-
tians (heat loss and
building ernelope calcs)
3. INDIREC"P FASTE CODIIVECTION
4. VEP7'PING APPLIANCES
Provided as required
by code - OiC
Indirect wastes from equipment MSPC 4715.1510, Request that condensate
not regularly classed as plinnbing from rooftop units be
fixtures, but having drainage allowed to drain onto
outlets, must be trapped, but roof (See Item 10.C,n
need not be vented Div. IV) - OR
A. Vent Terminals Shall he located at least 20 ft. 1345.1530, pg 90 Building is in
(Unit Heaters) horizontally or 10 ft. vertically compliance - aC
from any outside air intake
opening
T-360 Division IV
Page 1 of 7
bivision IV - Mechanical
!mm90TA STATE &TIIDING CODE, 1987 EDITIQd
CMPTER 1345, HVAC CODE (87 FISBC)
SR
TOPICS REQUIREMEN'PS SECTIONS gEMARKg
5. GINERATOR EXHPdJST PIPING
A. Flue Gas Temperatures Engine exhaust discharge 85 NFPA 37, Flue qas temperatures do
systems shall be designed on 6-1 not exceed 950 deg. F
the basis of flue gas temp- OK
eratures. When such teuper-
atures do not exceed 1000 deg. F.
(538 deg. C) except for infrequent
brief periods, the engines shall
be classified as low heat
appliances.
B. Exhaust Pipe Material Exhaust pipes shall be of SS NFPA 37, Schedule 40 steel pipe
wrought iron or steel and of 6-1.2 provided
sufficient strength to with-
stand the service.
C. Insulation Where necessary, exhaust 85 NE'PA 37, 2 inch thick calciinn
systeros shall be quarded to 6-2.4 silicate insulation
prevent personnel burns. provided; terminated
3 feet akwve roof
surface
T-360
Division IV
Paqe 2 of 7
m w ? m m ? ? m m m m m m m m m r m m
? ww
mutMM 1?Me???? E' 1987
EDmcm
cH14PfIIt 1345, HVAC OME (87 MSBC)
SR
TOPICS REQUIREMEN'PS SECTIONS REMARgg
6. COPffMEl2CIAL HOODS AND RITCHIIV VENTILATIOb7
A. Duct Enclosure Exhaust ducts shall be enclosed
in a onrhour rated shaft ex-
tending from the ceiling above the
hood through or to the roof.
Clearance from non-combustible
construction shall he not less
than 6".
B. Air Velocity
Hood Capacity
Exhaust ducts shall be sized to
maintain a velocity of 2000
to 3000 feet per minute
Island type hoods:
Q= 125 cfa/sf of hood area
Min. 50 cfm/sf office area
1345.1460, pg 87 Snack bar contains an
85 NePA 96, 3-5 island-type hood;
contiriuous 1-hour shaft
prwided from ceilinq to
eachaust fan on roof; 3"
clearance between duct-
work and shaft construc-
tion. 3" clearance is
acceptable.
liirnt. Eealth Dept.
inspector requires that
exhaust hood overlap all
equipment belvw by at
least 6".
1345.1460, pg 86 2000 FPM provided
for exhaust
1345.1770, pg 98 Hood exhaust area:
A = 31.5 sf, therefore,
Q = 3940 cfm;
xood exhaust face area:
80 sf, therefore, min.
Q= 9025 cfm; 4725 c5n
exhaust provided
T-360 Division IV
Page 3 of 7
Division IV - Mechanical
MIAP1M7A STATE BTJILDING i'ODE, 1987 mITION
CH4PTIIt 1345, HVAC OODE (87 MSBC)
SR
'1OPICS REQUIREMENTS SECTIONS gETIAM
7. INIItGY CONSERVATIOV
Comply with 1983 Model
Energy Code
MSBC 4215.0400
See Checklist Item
10.A,s Div. IV - Verify
aziy local requirements
8. DUCT SMOKE DETECTpRS
Systems between 2,000 cfm
and 15,000 cfm shall shut dvwn
automatically when the air
temperature becomes excessive, by
thermostatic devices or smoke
located as follows: (1) in the
return air stream ahead of any
outside air intake, and (1) in
the main supply duct dawmstream
of the filters.
1395.3300, pg 188
Smoke detectors are pro-
vided in the supply
duct. Will provide
in return if necessary.
(See Checklist Item
10.E., Div. IV).
9. GAS METER
A. Location Shall be such that the meter can 1395.2630
be easily read and the connec-
tions are readily accessible for
servicing and shall be acceptable
to qas supplier.
T-360
Proposed location -
within 5 ft. of rear of
building (see Checklist
Item 10.G.-J., Div. IV)
Division IV
Page 4 of 7
r m m m m m m m m m m m m m m m m m m
_ ovivow ?Mecmca? r M m m m m m m m m m m m
MIfwSO'rA STATE BUILDING OmE, 1987 EDITIaN
aMPTER 1345, HVAC CODE (87 t4SBC)
TOPICS REQUIRIIMENTS SECTIONS gp+IARKg
B. Main Shutoff When meter is installed on the 1345.2660
exterior of the lruilding, a main
shutoff valve shall be installed
on the inside of the building
between the meter and the first
branch gas line.
T-360 Division IV
Paqe 5 of 7
bivision IV - Mechanical
[IIQIEM MECMMCAL CODE, 1985 Bdition (85 iH4C)
SR
TOPICS gE=gEMENpS
REMP.RRS
10. CHECKI,IST
A. Compliance with
energy code
B. Submittal of Energy Code
Compliance Forms
( ) Not required
( X ) Required
( ) Not required
( % ) Required (ohtain forms or specify
information required)
1983 Model Fnergy Code and 1985
Mirm. F.nergy Code, chapters
1325 and 4215
Energy Calculatians are
required to be sulmitted.
Building emvelope and heat loss
calculations.
C. Draining of condensate
froan rooftop units to
roof
D. Water-cooled condenser
for ice machine
E. Smoke detectors in
main air duct downstream
side of filter only
F. Combining of exhaust
from toilet rooms and
janitor's closet.
G. Gas mter location
T-360
? R ) Acceptable
( ) Not acceptable (specify
alternative method)
( ) Acceptable
( R ) Not Acceptable
( 7C ) Acceptable
( ) Other requirements, specify
( x ) Acceptable
( ) Not Acceptahle
( x) Within 5 ft. of rear of building
( ) Other (specify)
Division IV
Page 6 of 7
r m m m m m m m m m m m m m m m r m m
? §MviM IVMechMal M M r M M M r M M M M M M
iIIdIFOtM MXMWICAL CODE, 1985 Edition (85 tA4C)
SR
TOPIC5 gEQ7lgEpENTS REMARKS
H. 2 psi qas system
2
J
Submittal of calculations
for two psi qas sytem
2 psi gas piping inside
building
( x 1 Approved
( ) Not approved
( ) Not required
{ R } Required
( X ) Acceptable
( ) Not acceptable
T-360 Division IV
Page 7 of 7
? swivIm VMWlwM m m m m m M M M M M M M M M
OEP1R'II'ffiW OE' HEALTH, PMMSO9A STATE PLUMING OODE, 1987 IDITICN
(H1PPER 4715 (87 19SPC)
SR
TDPICS REQUIREMENTS SECTIObIS REMARKS
1. WATER SERVICE PIPING
A. Freezing
2
3.
B. Separation of Services
I4dI:+:1 &.APM
Shall be installed below 9715.0390, pg 18
normal frost penetration
10 ft. of undisturbed or com- 4715.1710, pg 53
pacted earth between building
drain or sewer and water service
A. Size Shall be the same size as the
pipe being sexved up to 4" and
not less than 4" for larger
pipinq
4715.1010, pg 38
B. Location 50' apart for 3" diameter pipe or 4715.1010, pg 38
smaller and not more than 100'
apart for 4" diameter and over.
A. Snack Bar To be prwided when, in the
judgment of the P,dministrative
Authority, waste pre-treatment
is required.
4715.1110, pg 39
71-0" cover for irater
senrice pipinq
Buildinq in compliance
Provided - OR
Gtease trap not req,; red
Zt has been Target's
expecience in the past
that the snack bar dces
not have enough qrease
T-360 Division V
Page 1 of 6
Division V - Plwnbing
DEeAR'IIg1NT OF EiEALTH, Ammw1A SrATL PLtAmBnG CME, 1987 FDITI(m
(HAP7ER 4715 (87 MSPC)
SR
'POPICS REQUIREPffiVTS SECTIONS RFMARKS
shall be equipped with a flow producing equipment to
control device. requite a grease trap
and, therefore, it
is preferred not to
provide a grease trap.
(See Checklist Items
7.A, 1)-3), Div. V)
4. GRADE OF HORIZONTAL
DRAINAGE PIPING Less than 3" Pipe - 1/4"/ft slope 9715.2400, pg 65 Building in compliance
3" to 6" pipe - 1/8"/ft slope OaC
5. INDIRECT WASTES
A. Connections No device which is intended to be 4715.1500, pg 49 OR
used for the storage or holding of
food oc drink shall have any drain
pipe directly connected to any
soil, waste or vent pipe and shall
be discharged through an air break,
except a dishwashing or culinary
sink in a food prep room.
B. Piping Indirect waste pipes from equip- 4715.1510, pg 50
ment not regularly classed as
plumbing fixtures, trut have
drainage outlets, must be trapped,
but need not be vented.
T-360 Division V
Paqe 2 of 6
m ? ? ? m m ¦? ? ? m m m r m m m m m m
? ?vim V mwn? ? ? ? ? ? ? ? ? ? ? ? ? ? M
DEPAtt'IIMU OF HEAG1H, pm*ESOTR STATE PIUII+mIIE CODE, 1987 IDITIQN
CHAP7ER 9715 (87 MSPC)
SR
TOPICS REQUIREMED]TS SECTIONS RF.MARR3
6. vENTiI3G
A. Location of Terminals Terminate not less than 12" above 9715.2530, pg 76 Building in compliance
roof, at least 10' horizontally, 09
or 2' above, window, door, or
other opening.
B. Sizing Shall be determined from its 4715.2500, pg 73 euilding in compliance
length and total number of
fixture units
C. Floor Drains Floor drains used for recessed 4715.1300, pg 45
slop or similar receptors shall
be vented as a fixture. Floor
drains installed more than 25'
from a vented main or branch
shall be prwided with a vent
installed on the floor drain
branch.
D. Island Fixtures Traps for island sinks and 4715.2650, pg 79 Request apprwal to pro-
similar equiFanent may be vide island venting at
vented by extending the direct connected threr
vent as high as possible, ..., compartment sink (See
and then returning downward and Checklist Ztem 7.G.,
connecting to the horizontal Div V.). - 0IC
drain downstream from the verti-
cal from the vertical fixture If flaor dxains and
drain. funnel drains are re-
quired to have indivi-
A horizontal vent shall he taken dual vents request
off the vertical section of the apprwal to prwide
T-360 Division V
Page 3 of 6
bivision V - Plumbing
DEPAIYIIMENT OF HFALTH, NDRESOTPL STRM pi;pygM L,ppg, 1987 IDITICIV
(MUPl'ER 4715 (87 17SPC )
DUPICS gEQUIRQMFN'fs
SECTIO[VS gQMARg$
fixture vent.., and extended to
the partition where it can be
extended to the open air or con-
nected to another vent at least
6" abave the flood level of the
fixture served. Cleanouts shall
be provided on the vent piping.
T-360
island vents (See Check-
list item 7.G., Div V).
Division V
Paqe 4 of 6
m m m m m m m m m m m m m m m m m m m
? MMUvINn vo-Mltm% m m m m m m m m m m m - m m
[1NIFCM PLtHOIIG CODE, 1985 Edition (85 UPC)
SR
TOPICS REQUIRIIMENTS REMARRS
7. CHECKLIST
A. Grease trap (for
Snack Bar)
( R ) Not required
( ) Required
1) Fixtures required to be (?( ) 3-compartment sink
connected ( ) Other sinks
( ) Floor/funnel drains, specify
2) Size of grease trap
3) Special details for
gcease trap
B. Water lines for fire and
domestic water
( ) gallons
( ) Prwided by Building Official
( ) Use A/E Consultant typical detail
( R) Use separate lines for fire
protection and for domestic water
( ) Combined fire and domestic watec
1) eackflow prevention on ( R) Check valve required
fire protection line ( ) Double check valve required
( ) other, specify
C. Location of domestic ( ) Vault wtside building
water meter ( x) Inside buildinq
( ) Other, specify
( ) Special piping arrangement tequired,
specify
D. Indicect Wastes Required ( ) Vegetable sink Direct rraste acceptable for
( ) Hand sink these fiatures. All other
( ) 3-compartment sink Snack Bar equipment requires
ixxdirect waste.
T-360 Division V
Page 5 oE 6
Division V - Plumbing
t]TiICM PLtMnwG CODE, 1985 Editioat (85 UPC)
SR
MPICS gIXQi7IgIIyENTS
RFd9F.RK5
E. Funnel Drains { g) Acceptable ( ) Not acceptable, specify alternate nrethod
F. Rooftop Unit Condensate to ( R) Acceptable
Drain on Roof ( ) Not acceptable, specify alternate method
( R ) Traps required
G. Ventinq ( S) Floor drains and funnel drains within
25' of vented main need not have
individual vents
( ) Floor drains and furmel drains required
to be individually vented
( x ) "ISland Venting" acceptable
( ) Other
H. Depth of Cover
T-360
m m m m m m
Water secvice 71-0"
Sanitary/storm 31-6"
Health Department requires
cleanouts aai each leg. Recvd,
a detail from Health Department
for island venting.
Division V
Page 6 0£ 6
m m m m m m m m m m m m m
? =*iviFW VlWirAWbtefflW = = = = = = = = = _ _ = =
iIIdlFURM FIRE OODE, 1982 Editiaat (82 UFC)
mIIESO'1T STATE &TILDING CODE. 1986 EDITIQd
CMlPTER 7510, FIItE SAFL"P7t (86 t75FC)
TOPICS REQUIREMENTS SECTION75 " REMARKS
1. OCCUPANCY
A. Occupancy Classification Graup e-2 occupancy - Retail 82 UFC, 9.1170 OK
Stores, Office Buildings pg 30
2. A[.1TOMATIC SPRINRLER SYSTEMS
A. Location
Group B-2 occupancies more than
12,000 square feet floor area
82 UFC, 10.309(d) OR
pg 96
3. SAFETY DEVICES
A. Fire-Extinguishing Equip. Apprwed equipment shall be
provided for protection of
cooking type hoods.
B. Smoke Detectors
Shall be placed in the main air
duct on the downstream side of
the filters
C. Fire Dampers
D. Fire Extinguishers
9. SPRINKLER SPACING
A. Distance Between
Sprinklers and
eetween Branch
Lines
Provide in walls of 2-hour
rating or more
Prwide throuqhout buildinq
per NFPA standards
Light hazard
85 NFPA 96, 7-1.1 Prwidinq wet chemical
system - OK
85 NFPA 90A, 4-3
85 NFPA 90A,
3-3.2.1
85 [1E'PA 10
OK
No 2-hwr rraLis
Provided - OR
85 NFPA 13, Sprinkler subcantractor
4-2.1.1 to su6mit sprinkler
system drawings to
city
T-360 Division VI
Page 1 of 6
Division VI - Fire Protection
(JNIECtM IrIRS OODE, 1982 E7ditimt (82 DE1C)
!'III3NESm ST!?TE H[JILDING CODE, 1986 EDITIQN
(MP'lER 7510, FIRE SAFEP7t (86 MSFC)
SR
TDPICS REQiTIREME[dT5 SECTIONS ' REMARRS
B. Distance Between Wall
and End Sprinklers
Distance Setween Wall
and End Branch Line
S. HOSE CABINETS
Ordinary hazard 85 NFPA 13,
9-2.1.2
1/2 the distance between 85 NePA 13,
sprinklers on branch lines 4-2.1.5
1/2 the distance between
branch lines
Not required - _ _
6. SPRINKLER fEADS IN No piping, ducts or equipment 84 NEC, 384.2,
EI.ECTRICAL AND TELEPHONE ROOM foreign to this room shall be pg 70-265
permitted to be installed in,
entex or pass thcwgh.
7. AREA LIMITATI0N The maxiimmm floor area to be 85 NFPA 13,
protected by sprinklers on each 3-3
system riser on any one floor
shall be:
Light Fiazard - 52,000 sf
Ordinary Hazard - 52,000 sf
Palletized Rack Storage in
excess of 12 ft high - 90,000 sf
(Palletized Rack Storage not
used in Target store)
T-360
09
OiC
Provided as per
client's criteria - OR
Stub pipinq in and plug
off heads
Protected Areas
Sales: 83,077 sf
Warehouse/Stock:
25,149 sf
Offices/Mechanical/
Circ./Snack Bar/
Restrooms: 6.006
Total: 119,232
Three risers required
nivision VI
Page 2 of 6
m m m m m m m m m m m m m m m m m m m
? ?ivANW V=FicMotEMn M M M M M
I1NIF0M FIRE OODE, 1982 F7dition (82 UFC)
lIIlOMSO'fA STA7E HUILDIAIGG CODE, 1986 EDITIQN
CHAY= 7510, FIRE SAFE17f (86 ASYC)
SR
TOPICS REQUIREMENTS SECI'ZON5' RIIMARKS
Note: Office
Mezzanine (3,500 s#)
is a separate Ievel
and not considered
in the acea
calculations.
8. FIRE LANES-APPARA'IUS ACCESS Fire lanes are uaxier
RQADS
Placming Dept.
jurisdictian
A. Requirement Fire apparatus access roads are 82 UF'C, 10.207
cequired and shall extend to with- (a,c), pg 40
in 150' of all portions of the ex-
terior walls of the first story.
B. Clearances Access roadways shall be not less
than 20' of unobstnacted width,
with adequate turning radius,
and 131-6" of vertical clearance.
The chief shall have the authority 82 UFC, 10.207
to require an increase in the (e), pg 40
minimum access widths where such
width is not adequate for fire or
rescue operations.
C. Signaqe The marking of fire lanes on pri- MSFC 7210.1500,
vate and public property shall pg 6
be designated and approved by the
chief and the chief of police.
T-360
Division VI
Page 3 of 6
Division VI - Fire Protection
UNIPOm FIRB ODDE, 1982 Editian (82 UF'C)
rmaEsoTr, sTaE scrzr,nnac caDE, 1985 EDiTTaa
MAPTER 7510, FIRS SAFEiy (86 MSFC)
SR
TOPICS RE4tTIRECIENTS SECTION5 REMARKS
D. Obstructions 'ihe required width of access 82 UFC, 10.207 (b)
roadways shall not be obstructed
in any manner.
Parking of motor vehicles in, or MSFC 7510.1500,
othecwise obstructing, fire lanes pq 6
shall be prohibited at all times.
T-360
Division VI
Page 4 of 6
m m m m m m m m m m = m m m m m m m m
? M%iviM VPWirPWteRL M M M M M M M M M M M M M
UNIFQM FIRE CODfi, 1982 Edition (82 UFC)
PMR&50TA STATE BUILDING CODE, 1986 IDITION
CH4PPER 7510, F1RE SAFE'PY (86 MSFC)
SR
TDPICS REQJIRII+IEN'PS ' REMARRS
9. CEECKLIST
A. Security platforms ( x) Not required to }x sprinklered
under platform
Required to be sprinklered
under platform
B. Electrical and ( ) Acceptable to have smoke detection
Telephone Rooms device only
( ) Required to both be sprinklered
( R) Stub in sprinkler piping so heads could
be acHed later
C. Security Stocage ( ) Not required to be sprinklered
( x) Required to be sprinklered
D. Fire and domestic (?) Combined system acceptable
water service ( x) Separate systems reguired
E. Detectoc check valve ( x) Check valve only required
.for fire service (%„/) Detector check valve required
F. Fire protection system ( ) Two required
risers ( x ) Three required
G. Fire extinguisher ( x) Acceptable
locations ( ) Not acceptable
T-360 Division VI
Page 5 of 6
Division VI - Fire Protection
UNIFCM FIRE CODE, 1982 Edition (82 UFC)
MIICQSOTA STATE H[7ILDING CODE, 1986 mITION
(MPTER 7510, FIRS SAFL"17[ (86 17SE'C)
TOPICS gEQUIgEMMT5 •
REMARKS
H. Fire protection for
hood at Snack Bar
1. Smoke Detectors
for air handlinq units
J. Flannable liquids stocked
in huildinq
R. Access to post indicator
valves ancl siamese fire
department coruiection
T-360
( R) Wet chemical system acceptable
( ) Dry system required
( R) Locate per NE'PA 90-A dawnstream of
filters (in supply duct)
( ) Other requirements, specify
Building Official and Pire
Inspector received summazy of
quantities
5' maximum height above
exterior grade for PiVrs
and fire dept. connection.
Slopinq asphalt up to a
flat area for fire dept.
access to PiV and
siamese accepta6le.
Division VI
Page 6 of 6
m m m m m m m m m m m m m m m m m m m
m m m m m m m m m m m m m m m m m m m
Division viS - Electrical
MIIfmS07!? STATE HIJII.DIIM QODE, 1987 EDITION, fSM,Fl'ER 1315, 6[.F7CmICAL LCDE (87 MSEC)
SR
TOPICS REQUIREMENTS SECTIONS RII4ARKS/AC1'IKqN
1. GII9ERAL
A. Wiring Methods
2. EXIT ILLUMINATIODJ
Comply with the National
Electrical Code, 1987
A. General Exits shall be illwninated
at any time the building is
occupied with light having
the intensity of not less
than 1 footcandle at flooc
level
B. Power Supply
The power supply for exit illwa-
ination shall normally be pro-
vided by the premises wirinq
' system. In the event of its
failure, illuoination shall be
automatically pravided from an
emergency system where the
occapant load served by the
exitinq system exceeds 500.
Emergency systems shall be supplied
from storage batteries or from
an on-site generator set and
the system shall be installed in
accordance with the requirements
of the National Electric Code.
T-360
3313(a), pg 570
3313(b)2, pgs 570
and 571
K?l
Prwided - OK
Emergency swrce
prwided. See
Checklist Item C
at end of this
division. - 04C
Division VII
Paqe 1 of 3
Division vIi - Electrical
MII3VE90M STATE HUILDIHIG OODB, 1987 EDITIQQ, aMpTIIt 1315, E.WTCAL CME (87 ASBC)
TOPICS REQUIREMENTS SECTIONS gEMARR,g/ACTIpN
3. EXIT SIGNS
A. Where Required Install at required exit doorways 3314(a), pq 571 Prwided - 0!C
and where othen,Tise necessary to
clearly indicate the direction of
eqress.
S. Graphics Color of lettecing, arrows, etc., 3314(b), pq 571 Provided
shall be in high contrast to
their background, and use block
letters 6" in height and a
stroke of not less than 3/4".
C. Illwaination Internally or externally illimmi- 3314(c), pg 571
nated by two electric lamps, or
be of an approved self-luminous
type.
D. Power Supply When separate sources of power
are required foc exit illumina-
tion by Section 3313(b) Z,
power to one of the lamps for
exit siqns shall be from
storage batteries or an om
site generator set, and the
system shall be installed in
accocdance with the National
Electrical Code.
T-360
3314(d) 2, pg 571
Prwided; with
internal lamps.
Elmergency saurce
provided. See Check-
list Item C at the end
of this division.
Division VII
Page 2 of 3
m m m m m m m m m m m m m m m m m m m
m m m m m m ? m m m m m m m m m i m m
Division VII - Electrical
MDNESCIT& STATE &IILDING CME, 1987 IDITICN, CHAPTER 1315, EGEX.`II2ICAI. OOpE (87 NSFx)
SR
10PIC5 gEQqIgg"ENN'pS REMARKS/ACTIIXN
4. CEECKLIST
A. Telephone wiring and low (%) Not in conduit
voltage wirinq ( ) Required in conduit
B. Manufactured wiring ( R) Acceptable in ceiling space
system is used for inter- ( ) Not acceptable
connection of lighting
and telephone/pawer poles
in accordance with NEC
Article 604
C. Prototype fuel source for ( R) Acceptable (per NEC Article
on-site, emergency 700-12(b)(3) Exception)
generator is natural gas ( ) Not acceptable
supplied fzaaa the local
utility.
D. Service disconnecting ( R) Multiple main disconnects acceptable
means is prwided (per NEC Article 230-71)
thraugh multiple discon- ( ) Single main disconnect means
nect switches required
E. Reset of snack bar hood ( R) Acceptable
exhaust fan and electrical ( ) Require a readily accessible reset
equipment under hood after for hood only
shutdown, due to activation
of hood fire suppression
system, is done simultaneously
with the ability to reset hood
first, then the electrical
equiFsnent inder the hood
Ceiling space is not used as
an air plernm
T-360
Division VII
Page 3 of 3