Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
1964 Safari Tr
01/25/2011 09:47 9527589171 City of Ea 3830 Pilot Knob Road Eagan MN 55122 Phone: (651) 875-5675 Fax: (651) 675-5694 UPGRADE MECHANICAL PAGE 03103 Use BLUE or BLACK Ink MEM G Pemrit # / 3 -2- Permit Fee: 6iC70 bats Received: Staff. 1 2011 RESIDENTIAL t PLUMBING PERMIT AP}PUCATION p Oats: 1) # 1) Site Address: 1 ` 1 'i ' 1-r`'' Tenant: RESIDENT / OWNER Name: .., Suite 8: Phone: Address / City / Zip: CONTRACTOR TYPE OF WORK PERMIT TYPE Awe; 117 Wes-}• Ol to c24- 5 u L e rLicense #: 443E4. P 17") : Pyr e a TICCRy: Ncc 1 crag Slate: i N Zip: ,g>D7) 4 16 11 Phone: J 57- 191-00 d Contact:. ' 1_ Entail 13ei< . U er j Q yvl 4 a� . CD New Replacement _ R it Rebuild ►/ Modify Spate Work inAt.O_W. Desenlpfion of work: .-11(1/611 /k /IL r14.bA AZ/7 - .64.7i -A6( RES . r NTIAL ater Heater Lawn Irnyation ( RPZ / _ PVB) Septic System New Abandonment Water Softener Add Plumbing Fixtures Main I. Lower Level) Water Turnaround RESIDENTIAL FEES: $55.00 Minimum Water Heater, Water Softener, or Water Heater Ood Softener (includes $5.00 State Surcharge) $35.00 Lawn Irrigation (includes $5.00 State Surcharge) $55.00 Add Plumbing fixtures, Septic System &mamma Water Tumaroundt (includes 55.00 State Surcharge) "Water Turnaround (add $166.00 If a 5!5' meter Is required) $105.00 Septic System (510.00 per as butt) (indudes County fee and 55-00 State Surcharge) $95.00 Flre Repair (replace burned Out appliances, ductwork, etc.) (includes 55.00 State Surcharge) TOTAL. FEES $ CALL BEFORE YOU DIG. Call Gopher Stan One Call at (651) 454-0002 for protection against underground utility damage. Call 48 hours before you intend to dig to receive locates of underground ut6ities. www.gopherstateonecaliorg I hereby acknowledge that this information is complete and accurate; that the work wwl be In cenfomrence with the ordinances and aides of the City of Eagan; that I trderstand this is not a perms, but only an appYcauon for a puma, and work Is not to start without a permit; that the wink Nil be In accordance wllh the approved plan in the case of work which requires a review and appealed of pier>a. ;eery+ R o `,'t v. 4&.* Appliceat i Printed Name Applicant's Signature FOR OFFICE USE Required Inspections: Linder Ground Rough -In _Air Test Gas Teat Final Reviewed By: Date: 01/25/2011 09:47 9527589171 CityofEall a 3830 Pilot Knob Road Eagan MN 55122,, Phone: (681) 675-5675 Fax: (6511675-5694 Daus: 1 ) 1/) UPGRADE MECHANICAL PAGE 02/03 Use BLUE or BLACK Ink 1�IA Pemlit. q7q:5.7 Permit Fee: 0 Date Received: Staff: 2011 MECHANICAL PERMIT APPLICATION Stgrr Adidroas: Tenant Suite 0: RESIDENT / OWNER Name; Phone: AddressCity! Zip: CONTRACTOR A/ , �y ` �Q Name: U f C Q Y} r 14� V)r�c` I rl ;cense # ) '4 J�Y� .�1 c We.4- O)Q► d _ may; N +P P 0e_ Addrese::�1 `_ p,G State: t T 1`i Zip: 5oril I Phone: !." ti ` 006 Contact: j`' TC..- Emdll: ' - 4-C . u * # d. r 4 ;) . C AP. TYPE OF WORK .. New Replacement Alteration Dem/oiitivn nn _--Additional Description of INCA: Med 441' G I . -1 /j� I i �i11 /421 L # T7 NOTE: Roof mounted and ground mounted msdfardcal equipment Is required to be screened by City Cods. Please Contact the [M.cbanlcel Inspector for information on permitted screening methods. PERMIT TYPE RESIDENTIAL 1111808, - Conditioner Exchanger COMMERCIAL New Construction_ Interior improvement install Piping _ Processed Gans Exterior HVAC Unit Heat Purnp Under! Above ground Tank (_... Intel I Remove) Other _ ^ " When instaebgfrenwving tank(a). call for Inspection by Fire and Plumbing Inspector RESIDENTIAL FEES: $55.00 MInit!! ern Add-on or alteration to an existing unit (includes $95.00 Fire repair (replace burned out appliances. ductwork, etc.) (includes �fdarshal W $5.00 State Surcharge) $5.00 State Surcharge) $ TOTAL FEE COMMERCIAL FEES: $75.00 Underground tank 555.00 Minimum (Includes installation/removal OR State Surcharge) S10,010, surcharott is $ 5.00 sunt urge increases by L-50 far each S1 ,000 Permit Fee requires a $ 5.50 surcharge) - Contract Value $ x 1% $ Permit Fee - If the Permit E is tess than - if the Euturl Fig is $10,010, (ie, a $10,010-$11,010 Permit Fee = $ Surdtarge = $ TOTAL FEE CALL BEFORE YOU DIG. Call topes State One Call at (ff51) 45440002 for protection against urrdaroround uogty damage- Caen 45 tours beton: you Intend o dig to receive locates of underground utilities, sztuarmuddegemolai Ihereby edarowladpe that pus information is complete and ante; that the work vIlI be In conformance vrtin the Ordinances and codes of the City of Sagan; that I understand this 1s not a permit, but only an application for a permit, and work is natio start vA haul a permit mat the wok v6Il be in accordance with tt* approved plan in the case of work whkt requires a review any approval of piens. N_Wi1(,A2^ tooc,,f ✓AL.. Applicant', Printed Name FOR OFFICE usE x R. -0214J Appl'icant's Signature Reviewed By: Date: �— Required knspectiont a Under Ground Rough In Alr Test Gas Service Test `in-flgw Meat Final Exterior HVAC Screening Inspection _0' 77Y9(v zUlzte 5201 hi. Rive' Road Slow 308 Mijweapoli,. MiN 55421 w 763571-'-5011 c.... 763-571 .1 Ills w%m.ul lei glum Date: December 19, 2008 To: Chad Hess w/ Advance Wall Systems 16927 231st Avenue NW Big Lake, MN 55309 From: Trevor Axner, PE Subject: Swedberg Residence -Safari Trail, Eagan, MN ?Glb Project Number: 207.0443 Ulteig previously performed a structural engineering review of the ICF construction, steel beams, and concrete footings for the above residence. Refer to the drawings prepared by Ulteig dated 4-19-07 for more information. During construction, an ICF lintel at the front of the house over the bay window in the den / guest room was modified for an incorrectly placed top of rough opening elevation. The lower reinforcement and concrete was cut out due to the modification. AWS, the contractor, consulted with Ulteig prior to making the necessary concrete removal. The residence is nearing completion and issuing of a Certificate of Occupancy. The City Building inspector is requesting documentation of our review. The following information was reported during construction by the contractor: 1. The ICF concrete lintel spans approximately nine feet. 2. The concrete depth between the top of the opening and the bottom of the window above is approximately four feet. This full depth was likely placed during two pours, the lower pour being approximately 32" in depth. 3. The lintel is non-bearing with the exception of mono-trusses from the adjacent porch roof, as well as minor tributary floor and roof loading. Upon review, Ulteig determined that the modified lintel is structurally adequate to support all required design loads in accordance with the Code. Please contact Ulteig Engineers if you have any questions or comments. I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly licensed professional engineer under the laws of the State of Minnesota. Trevor Axner Minnesota Registration No. 45470 Date: 12-19-08 _ k L -77y9& 8)?,yy, 7q I? LL -7 `76197 610'_'50 2007 RESIDENTIAL BUILDING PERMIT APPLICATION If l? 1 - 09 co . C5,0 City Of Eagan 3830 Pilot Knob Road, Eagan AIN 55122 Telephone # 651-675-5675 FAX # 651-675-5694 nn? VewConsimcdon Re uirements RemodeVRegair Requirements L office (fee only Ced of Survey Recd - 3 registered site surveys showing sq. ft. of lot, sq. ft of house; and all roofed areas 2 copies of plan showing foofings, beams, joists _Y (20%mmimum lot coverage allowed) 1 set of Energy Calculations for heated additions _Y Soils Report_ 1 Soils Report if proposed building is lo be placed on disturbed sail 1 site survey for additions & decks , copies of plan showing beam &window sizes; poured found design, etc. Addition - indicate if on-site septic system _Y, Plans Wm Joist Detail are Options selection sheet considered (buildings public with 3 or less units) information C unless you state the are trade secret and the reason. 1 set of Energy calculations r/ _Y 3 copies of Tree Preservation Plan if lot platted after 7/1N3 `7 ? ??? ? y/Mlnnegasco mechanical ventilation tam _> T- Date ? / / Q Construction Cost Site Address T' r C? ! UniUSte # ?- C? c4 a- n 44 AZ 2-2- Description of Work Ale- e- L+J No m e- Con S / r u n 11) Multi-Family Bldg - V Y N - 1 - 2 - Fireplace(s) A 0 P O t rk c ' hode # (?OS ><) ?j a - 9 ,o f q f u? - 1'el roper wner y p b e r I (..- b b -Cam! ! Contractor a-r t L F--s Lo f- clk e v- t Address a 10 / vt M JV Rd. - Ci /? Q a d_ State M A/ /i Zip 5rj 12- Z Telephone # (/pSj)?y ' ? to g' COMPLETE THIS AREA ONLY IF CONSTRUCTING A NEW BUILDING N - Minnesota Rules 7670 Category I - Minnesota Rules 7672 spy Energy Code Category • Residential Ventilation Category 1 Worksheet New Energy Code Wow (J submission type) Submitted Submitled? . Energy Envelope Calculations Submitted In the last 12 month has the City of Eagan issued a permit for a similar plan based on a master plan? - Y N If yes, date and address of master plan: Licensed Plumber 1 _ tt.fl 5 o t'N e l lu?M 6 f rl A C tea {l h? Telephone # 176 ? Y a 7 - 7 ? go Mechanical Contractor La f 5 on I- I u w\ ?? t Telephone # (N) a 7- 7 (e Sewer/Water Contractor (AN d.L)ftri.i A44-4(A,0% AJ Telephone I hereby apply for a Residential Building Permit and acknowledge that the ?sr7y C ???Cl ?-7 Tree Pres Plan Recd Tree Pros Required „. On-si0e Septic System accurat e; that the work will be in conformance with the ordinances and codes of the City of Eagan and the State of MN Statutes; I understand this is not a permit, but only an application for a permit, and work is not to start without a permit; that the work will be in accordance with the approved plan in the case of work which requires a review and approval of plans. /?ru E. P.? Appll ?Vs AAAA?1Rlicant's rinture DO NOT WRITE BELOW THIS LINE Sub Tvpes ? 01 Foundation ? 07 05-plex ? 13 16-plex ? 20 Pool ? 30 Accessory Bldg 0 02 SF Dwelling ? 08 06-piex ? 16 Fireplace ? 21 Porch (3-sea.) ? 31 Ext. Alt - Multi ? 03 01of_plex ? 09 07-piex ? 17 Garage ? 22 Porch/Addn.(4-sea.) ? 33 Ext. Alt - SF ? 04 02-piex ? 10 08-plex ? 18 Deck ? 23 Porch (screen/gazebo/pergola) ? 36 Mufti Misc. ? 05 03-piex ? 11 10-piex ? 19 Lower Level ? 24 Storm Damage ? 06 04-piex ? 12 12-plex % nc) V Pe5 ? 25 Miscellaneous SifYc)-e peclt WorkT es 31 New ? 35 Int Improvement ? 38 Demolish Interior ? 44 Siding ? 32 Addition ? 36 Move Building ? 42 Demolish Foundation ? 45 Fire Repair ? 33 Alteration ? 37 Demolish Building" ? 43 Reroof ? 46 Windows/Doors ? 34 Replacement 'Demolition (Entire Bldg) - Give PCA handout to applicant Description: Water Damage _ Yes Valuation 323 j Z)C?0 .10_'Z?-Occupancy R -3 MCES System Plan Review 't-0 100% or - 25% Census Code U t Zoning 9? - City Water SAC Units ?Z l Stories Z Booster Pump # of Units ( Sq. Ft. 3 c.)a? PRV # of Bldgs O ) Length (10 S_ Fire Sprinklered Type of Const Y9 Width 7.!?_ REQUIRED INSPECTIONS YP Footings (new bldg) _ Sheetrock Footings (deck) ?- Final/C.O. _ Footings (addition) _ Final/No C.O. Foundation _ HVAC Drain Tile Other _ Roof ?'4 Ice & Water Pool _ Figs _ Air/Gas Tests Final _ Final Framing _ _ Siding X Stucco Lath A Stone Lath -Brick Windows p Fireplace L° R.I. ? Air Test ;4 Final Insulation _ _ Retaining Wall Approved By: Building Inspector --- ---------- ----- - - - - - - - --- - - Base Fee Surcharge Plan Review MC/ES SAC City SAC Utility Connection Charge S&W Permit & Surcharge Treatment Plant License Search Copies Other Total ?ec?? u PPeR >?D ?owC'?- F-1/-Y+ ?eG 3?ot?: G-,?2Rge (zya sy.r<-t.?c 33.6$ ST FlooR Zppo?R s9 rYY.? .78 and 79.7.8 CaJepze% 5( X gfi_5emcofi 59.Pt-X/s .5a s? 'Ft' r 33 6? ?e¢ ??,e1G?tlz ? 36-7 Address: 1964 Safari Trail Zip: 55122 THE FOLLOWING ITEMS WERE/WERE NOT COMPLETE AT FINAL INSPECTION QN : 6? -7-760 Permit: 77496 • Verify with your builder that roof test caps from the plumbing system have been removed. • Turn off water supply to the outside lawn faucets before freeze potential exists. • Call the City's Engineering Department at 651-675-5646 prior to working in right-of-way or installing irrigation system. BUILDING INSPECTOR. GBldg Insp/Forms/2007/Checklists Yes No Comments Final grade - 6" from siding Y Permanent steps - garage Permanent steps - main entry Y Permanent driveway Permanent gas '[ Retaining Wall or 3:1 Max Slope Sod/Seeded lawn Trail/curb damage Porch )G Lower level finish Deck 7c 6a6,A0 Fireplace x • Verify with your builder that roof test caps from the plumbing system have been removed. • Turn off water supply to the outside lawn faucets before freeze potential exists. • Call the City's Engineering Department at 651-675-5646 prior to working in right-of-way or installing irrigation system. BUILDING INSPECTOR. GBldg Insp/Forms/2007/Checklists Date: 4/16/07 Revision Date: 04/16/2007 New Construction Site Information Address 1: Project #: Address 2: 1964 Safari n Lot: Block: City: County: Dakota Subdivision: Application Information Business Name: MN Contractor License #: Contact Person: Office Ph: Fax: Cell Ph: Address 1: City: State: Zip Code: House Details Square Feet: 5590 sq. ft. Avg. Ceiling Ht: 8.5 ft. Number of Bedrooms: 6 Ventilation : Balanced Total Ventilation Capacity : 208 cfm. Minimum Continuous Ventilation :105cfm. Intermittent Ventilation: 103 cfm. Combustion Appliance Water Heater 1: Power Vent Input BTUs: 40,000 Independently Vented Water Heater 2: Power Vent Input BTUs: 40,000 Independently Vented Furnace/Boiler: Direct Vent/Sealed Combustion Input BTUs: 120,000 Independently Vented Other Combustion Appliances Gas Fired Direct Vent Fireplace(s): No Gas Fired Power Vent Fireplace(s): No Gas Fired Natural Draft Fireplace(s): No Solid Fuel Appliance(s): No Exhaust Equipment Continuous Exhaust Ventilation Capacity (cfm): NA Clothes Dryer (cfm): 135 Exhaust Fan Rating (cfm): 400 Make -Up Air No Make -Up Air Required by Code Combustion Air Round Rigid Required: 5 inches or Insulated Flex: 6 inches Applicant Name (print) 1P SignaturelDate L •.•4 T- 2-07 Code Official (print): Signature/Date: © 2004 CenterPoint Energy Minnegasco. 2004 Mechanical Code Guidelines. Page 1 Project Title: SWEDBERG RESIDENCE Report Date: 02126107 Data filename: Untitled.rck Energy Code: 2006 IECC Location: Eagan, Minnesota Construction Type: Single Family Conditioned Floor Area: 1975 ft2 Glazing Area Percentage: 15% Heating Degree Days: 7981 Climate Zone: 6 Construction Site: Owner/Agent: Designer/Contractor: ADVANCED WALL SYSTEMS STOCK BUILDING SUPPLY EAGAN Ceiling 1: Raised or Energy Truss: 1975 44.0 0.0 53 Wall 1: Insulated Concrete Forms: 4394 32.0 119 Window 1: Vinyl Frame:Double Pane with Low-E: 662 0.330 218 SHGC: 0.35 Door 1: Solid: 130 0.350 46 Basement Wall 1: Insulated Concrete Forms: 1800 32.0 50 Wall height: 9.0' Depth below grade: 8.0' Insulation depth: 9.0' Compliance Statement.., The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed bu ilding has been designed to meet the 2006 IECC requirements in REScheck Version 4.0.1 and to comply with the mandatory require rents listed in the REScheck Inspection Checklist. Name - Title Signature T Date SWEDBERG RESIDENCE Page 1 of 1 LOT SURVEY CHECKLIST FOR RESIDENTIAL BUILDING PERMIT APPLICATION i n 1 1, ? --T1 - G C, ? rd nom) PROPERTYLEGAL: DATE OF SURVEY: .Vis1o7 LATEST REVISION: 41 J?W m m c m t U a Oz Q ,a o ? z ? ? .0' ? ? W 9 ? 0 D0 B ? ? ,0 ? ? $ D ,0' ^ /}3 ? ? Nom' ? yJ J3 ? 'z DOCUMENT STANDARDS • Registered Land Surveyor signature and company • Building Permit Applicant • Legal description • Address 1 ' • North arrow and cafe ?.6w SnKYX4J Lb- 4X. /7 • House type (ram walkout, split w/o, split entry, lookout, etc.) • Directional drainage arrows with slope/gradient % • Proposed/existing sewer and water services & invert elevation • Street name • Driveway (grade & width - in R/W and back of curb, 22' max.) • Lot Square Footage • Lot Coverage ELEVATIONS Existing ? ? Property comers 'K ? ? Top of curb at the driveway and property line extensions .0 0 ? Elevations of any existing adjacent homes '?? ? ? • Adequate footing depth of structures due to adjacent utility trenches ? e 0 Waterways (pond, stream, etc.) Prooosed ? 0 • Garage floor 0 ff • Basementfloor- i4;hi mOd, AGUAe p).,- ?o+?sL'a1a,r S-t psUS S(, ? 5?? hi ? _ ? ? ? • Lowest exposed elevation(walkout/window) W1JP?r jig, 4swr} 9 Property comers Mn/ ? • Front and rear of home at the foundation - (raf pyoSea? eiKl. 5 L 'nt ld ACtiA Lo wes4 q /%or 6J -o, -rrcoEC? e s kAq ?Iocvl eIM. PONDING AREA (if applicable) 0 )d ? • Easement line - ? 0 ? • NWL D 'z ? • HWL 0 'z ? • Pond # designation ? 'z ? • Emergency Overflow Elevation 0 0 0 • Pond/Wetland buffer delineation y • Shoreland Zoning Overlay District Y Jv? • Conservation Easements 0 ? ? X • Lot lines/Bearings & dimensions and street width (to back of curb) Ri ht f E 9 ? ? 9 . g -o -way osed home dimensions including any proposed decks, overhangs greater than porches, tc. • Pro J p (i.e. all structures requiring permanent footings) 'z ? ? • Show all easements of record and any City utilities within those easements ,' ? ? Setbacks of proposed structure and dey r se ack of adjacent existing structures pr ? ? Retaining wall requirements: ?, ' Date d B i R , y: ev ewe G:/FORMSBuilding Permit Application Rev. 11-26-04 i54 T DRAWING INDEX " M SA-1A INDEX & CERTIFICATION / SA-1B SCOPE & USE GUIDELINES 9 SA-1C GENERAL NOTES ? SA-2A TYPICAL ABOVE GRADE WALL SECTION ? SA-26 LEDGER CONNECTIONS ? SA-3 NON-BEARING WALL BLOCKING ? SA-4 LEDGE DETAILS ? SA-5A LINTEL SECTION AND REINFORCEMENT TABLE ? SA-513 LINTEL SECTION AND REINFORCEMENT TABLE ? SA-5C LINTEL SECTION AND REINFORCEMENT TABLE ? SA-5D LINTEL SECTION AND REINFORCEMENT TABLE ? SA-5E LINTEL SECTION AND REINFORCEMENT TABLE ? SA-51F LINTEL SECTION AND REINFORCEMENT TABLE I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Professional Engineer under the laws of the States of Minnesota & Wisconsin. Print Name: CRAIG L. OSWELL Signed: ?i -mac Date: 01/01/06 MN License Number: 42341 WI License Number: E-37911 tpULLl(11 3GOly: CRAIG L. OWL Ot MN /ANAL rluntrll 2006 MASTER INSULATED CONCRETE I ADVANCED WALL SYSTEMS, INC. I 5309 BIG LAKE, MN 9 16927 231st AVENUE NW FORM ABOVE GRADE WALL DRAWINGS , 1 Phone: (763) 263-8512 Fax: (763) 263-5912 INDEX & CERTIFICATION 5201 East River Road Suite 300 M'mrwapdis, Minnesota 55421 Phone: 763.571 25W Fax: 763.571.1159 9kM. Druid, Ukda - F.,W - Werbi,k5 - Sera Falk Web: www Mte'pcan Joe SITE INFORMATION (lo be Filed out by the conl[Wor) Ownet'. Sheet Address: Dare engineers orawney,Treyoacram PmlectNUnmar'.. e? SA-1A CM1eGed Oy: Tlevor Axner Oete', Januer 1.2008 ' 1 ARFRVd Sy: Craigoswel Clly: Slate:-ZIP CCde:_ SM1eels: 1 .'1 13 DRAWING SCOPE & USE GUIDELINES SCOPE OF WORK THESE YEAR 2006 INSULATED CONCRETE FORM (I.C.F.) ABOVE GRADE WALL DRAWINGS, CONSISTING OF SA-1 THROUGH SA-5 AND DATED 1-1-06, ARE PREPARED BY ULTEIG ENGINEERS, INC. THESE DRAWINGS CONTAIN STRUCTURAL DESIGN INFORMATION AND DETAILS TO BE USED IN THE CONSTRUCTION OF I.C.F. ABOVE GRADE WALLS FOR VARIOUS CONDITIONS COMMON WITHIN THE RESIDENTIAL MARKET ONLY. THE INFORMATION IS INTENDED FOR THE I.C.F. CONTRACTOR, AS WELL AS THE GENERAL CONTRACTOR AND THE FRAMING CONTRACTOR. THESE DRAWINGS ARE CERTIFIED AND PREPARED TO THE REQUIREMENTS OF THE INTERNATIONAL RESIDENTIAL CODE (IRC), AS WELL AS THOSE OF THE MINNESOTA AND WISCONSIN STATE BUILDING CODES. THESE DRAWINGS ARE VALID THROUGH DECEMBER 31, 2006. THESE DRAWINGS ARE LICENSED THROUGH AN AGREEMENT BETWEEN ULTEIG:AND THE LICENSEE NOTED IN THE TITLE BLOCK BELOW. THESE DRAWINGS ARE TO :BE USED SOLELY FOR PROJECTS IN WHICH THE LICENSEE IS DIRECTLY RESPONSIBLE. THESE DRAWINGS MAY BE RELEASED BY THE LICENSEE TO ITS AUTHORIZED AGENTS ! USE IN PROCUREMENT OF BUILDING PERMITS AND CONSTRUCTION INVOLVING THEIR I.C.F. INSTALLATION ONLY. ALL OTHER USES ARE PROHIBITED. USE GUIDELINES FOR EACH PROJECT, THE LICENSEE IS TO INDICATE THE APPLICABLE SHEETS OF THE DRAWINGS ON THE INDEX SHEET AND THEN SUBMIT THEM WITH THE FULL CONSTRUCTION DOCUMENT PACKAGE TO THE APPROPRIATE CITY BUILDING DEPARTMENT AT THE TIME OF PERMIT APPLICATION OR IN ACCORDANCE WITH AN ALTERNATIVE METHOD APPROVED BY THE CITY. THE CITY BUILDING INSPECTIONS DEPARTMENT WILL REVIEW THE DRAWINGS AND USE THEM DURING INSPECTIONS TO ENSURE COMPLIANCE. THESE DRAWINGS ARE PRIMARILY APPLICABLE TO THE FOLLOWING CONDITIONS:', 1. ABOVE GRADE WALLS TWELVE FEET OR LESS IN HEIGHT 2. OVERALL BUILDING HEIGHT NOT EXCEEDING TWO STORIES PLUS A BASEMENT 3. FLOOR SPANS NOT EXCEEDING TWENTY FEET CLEAR (ELSE ADJUST LEDGER CONNECTIONS AS REQUIRED) 4. WOOD JOIST, LUMBER, OR TRUSS FLOOR AND ROOF SYSTEMS SPECIAL CONSIDERATION AND DESIGN MAY BE REQUIRED FOR CONDITIONS' BEYOND THESE LIMITS. 12006 MASTER INSULATED CONCRETE I ADVANCED WALL SYSTEMS, INC- I FORM ABOVE GRADE WALL DRAWINGS 16927231st AVENUE NW, BIG LAKE, MN 515309 SCOPE & USE GUIDELINES Phone: (763) 263-9512 Fax: (763) 263-5912 5201 East River Road Suile 363 MleneaPois, Miallesola 55621 Phone: 763.571.2500 Fax: 763571 11U Bahri - DekoftLakes Fargo N'nnarai-Sioux Fwia Wet: www.ulteigcorh engineers Drawn By. Troy DaGrow Chearae By: Trevor Axner Avoro By: Craig OSwell JOB SITE INFORMATION Do lee 1111 out by the oontre,lorl O hin: slreel ABOress' cAy: state:-no c-._ Dar. Naman:iua zos.1966 SA-1B Dale: Jan ry 1.2006 $11ee16: 2 01113 GENERAL STRUCTURAL NOTES NOTES 1. THESE DRAWINGS APPLY TO ABOVE GRADE WALLS 12 FEET OR LESS IN HEIGHT. BUILDING HEIGHT IS NOT TO EXCEED TWO STORIES PLUS A BASEMENT. FOR LEDGER CONNECTIONS, ANCHOR SPACING SHOWN IS BASED ON A MAXIMUM FLOOR SPAN OF 20 FOOT CLEAR. IF FLOOR SPANS ARE IN EXCESS OF THIS DISTANCE OR IF ADDITIONAL LOADS SUCH AS LIGHT WEIGHT CONCRETE TOPPING ARE APPLIED, DECREASE LEDGER CONNECTION SPACING (ANCHORS OR ICFVL'S) ACCORDINGLY. 2. THESE DETAILS APPLY EQUALLY TO THE 4" AND GREATER FLAT FORMS, UNLESS SPECIFICALLY NOTED OTHERWISE. 3. HORIZONTAL WALL REINFORCING, UNLESS NOTED, CAN BE PLACED ANYWHERE WITHIN THE WIDTH OF THE WALL, ASSUMING MINIMUM COVER REQUIREMENTS ARE MET. PER ACI 318 CHAPTER 7, MINIMUM CLEAR COVER IS -/4". 4. SPLICES NEED NOT BE TIED PROVIDED BAR CENTERLINES ARE WITHIN 2 INCHES OF EACH OTHER. ALL BAR SPLICES SHOULD BE A MINIMUM OF 48 BAR DIAMETERS. 5. BARS MAY BE BUNDLED UP TO THREE TO A BUNDLE. 6. UNLESS SPECIFICALLY NOTED, DOWELS MAY BE DRILLED AND SNUGGLY FIT IN PLACE. DOWELS DO NOT NEED TO BE TIED TO THE VERTICAL STEEL. 7. PLACE BARS SUCH THAT THEIR FINAL POSITION IS WITHIN 'A" OF THAT SHOWN IN THE DETAILS. TYING OF BARS IN PLACE IS NOT REQUIRED PROVIDED THAT SUFFICIENT CARE IS TAKEN TO ENSURE THAT THE BARS DO NOT MOVE OUT OF TOLERANCE POSITION AND ALL CLEAR COVER REQUIREMENTS ARE MET. 8. PROVIDE MATCHING HOOK BARS FOR ALL HORIZONTAL BARS AT ALL WALL; CORNERS AND INTERSECTIONS. LAP ALL HOOKS AND HORIZONTAL BARS PER NOTE 4. HORIZONTAL BARS MAY BE CONTINUOUS AND BENT AROUND CORNERS IN PLACE OF HOOKS. 12006 MASTER INSULATED CONCRETE I ADVANCED WALL SYSTEMS, INC. FORM ABOVE GRADE WALL DRAWINGS 16927231st AVENUE NW, BIG LAKE, MN 515309 GENERAL NOTES Phone: (763) 263-8512 Fax: (763) 263-59112 5201 East River Read SUlta 30 MmeapbU.Mirmeaola 55x21 Phone: 70.571 Me Fax: 769.571.1160 Baran i oalrO Lakes - Farno - WrWaiars - B'ear, Fans Web: www Nlaig.carn engineers Drawn By: Troy Dai Che ej By. Trevor Axrar A,..d By: Craig Oewe11 JOB SITE INFORMATION (10 be lino pvt by ew conpacmrl I p.m. UmLec ,1 BB SA-1 C ele: January t Beim; CM: Slate:-Zp OO6e:- BMele: 30113 NOTES 1, INSTALL A MINIMUM OF (2) ANCHORS PER PORTION OF SILL PLATE AS WELL AS AN ANCHOR WITHIN 12" OF EACH END. 2. SPECIAL REVIEW 1S REQUIRED FOR WALLS HIGHER THAN 12 FEET, 3. INCREASE VERTICAL REBAR TO °4 BARS @ 24" O.C. FOR THE 4" FLAT 1CF WALL OPTION. REINFORCEMENT MAY BE "4 VERTICAL BARS @ 48" D.C. FOR WALL HEIGHTS LESS THAN 10 FEET, 1/2 "0 x 10" LONG ANCHOR BOLTS w/ (1) NUT & HEAVY DUTY WASHER @ 72" O.C. (7" MIN. EMBED) OR SIMPSON MAB15 OR APPROVED EQUAL @ 72" D.C. I °4 HORIZONTAL I,i BARS @ 48" O.C. I i14 VERTICAL °i- BARS @ 48" O.C. CENTERED IN WALL VERTICAL BARS MAY BE OMITTED AT WALL HEIGHTS LESS THAN 10'-0'1 1 I ICF FLAT FORM i° WALL (6" MIN. CONCRETE PORTION) e _ I 44 x 2'-0" i ° DOWELS @ 72" D.C. 1 (5" MIN, EMBED) ? SEE DETAILS -- ON SHEET SA-2B FOR LEDGER CONNECTION GROUT CUT -? OUT SOLID BEHIND LEDGER IF ANCHOR BOLTS ARE USED MATERIALS CONCRETE (28 DAY); 3500 PSI AGGREGATE; WALLS - 3/4" MAX REINFORCING; ASTM A615 GRADE 60 ADS LIVE LOAD; 42 PSF ROOF MAX, LIVE LOAD; 40 PSF FLOOR DEAD LOAD; 15 PSF ROOF DEAD LOAD; 12 PSF FLOOR WIND LOAD; 90 MPH EXPOSURE B ROOF OR FLOOR SYSTEM AND CONNECTION TO PLATE BY OTHERS SEE BELOW GRADE T PACKAGE FOR WALL REINFORCING 0 01 DO NOT PASS VERTICAL BARS FROM FOUNDATION INTO HIGH WALL WALL SECTION 12006 MASTER INSULATED CONCRETE I ADVANCED WALL SYSTEMS, INC. I FORM ABOVE GRADE WALL DRAWINGS 16927 231st AVENUE NW, BIG LAKE, MN 55309 TYPICAL ABOVE GRADE WALL SECTION Phone: (763) 263-8512 Fax: (763) 263-5912 5201 E6et Rlver R.W Sidle" 14nnii.We. Aim,eE S 21 PI 763.571.25M Fax: 763.571 1168 8ama -Diteo3 L6Ye6 Faryo Naveapo4s Siwn Falls Weh: wWw.ultft.. engineers prawn By. Troy Do,3.1 Clm, c By. TrevorAmer AWroveh By Craig [Mwe11 -' Psolect NU r,hec Dale: Janu Zg CoOe' SMetc: SA-2A JOB SITE INFORI&TION Bo De IIIIeE W by the..l..rl StrW ApV,ee6: NpIES 1. INSTALL A MINIMUM OF (2) ANCHORS PER PORTION OF LEDGER BOARD AS WELL AS AN ANCHOR WITHIN 12" OF EACH END. 2, PLASTIC BOLT HOLDERS MAY BE USED TO ALIGN ANCHOR BOLTS FOR LEDGER BOARD, 3. ANCHOR BOLTS MAY BE PLACED IN PAIRS AT 2 X THE SPACING SHOWN. 4, LEDGER MAY BE UNTREATED AT FOAM CUT OUT PROVIDED ADEQUATE MEMBRANE IS USED, MATERIALS CONCRETE (28 DAY); 3500 PSI AGGREGATE; WALLS - 3/4" MAX REINFORCING; ASTM A615 GRADE 60 LOAN LIVE LOAD; 42 PSF ROOF MAX.- LIVE LOAD; 40 PSF FLOOR DEAD LOAD;15 PSF ROOF DEAD LOAD; 12 PSF FLOOR WIND LOAD; 90 MPH EXPOSURE B HANGER CONNECTION BY OTHERS ° FLOOR J01STS BY OTHERS - ° t/z"o x B" LONG ANCHOR BOLTS w/ a ! HEAVY DUTY WASHERS @ 12" O.C. STAGGERED OR SIMPSON ICFVL @ 48" O.C. I' 6wl (6) SIMPSON D3 SCREWS 2 x 10 NO. 2 GRADE DETAIL MIN. LEDGER BOARD I-JOIST OR 2 x FLOOR SYSTEM SPACING = 24" O.C. MAX ACTUAL SPACING BY OTHERS BOTTOM CHORD BEARING TRUSS CONNECTION SIMILAR w/ APPROPRIATE ;HANGER INCREASE LEDGER DEPTH & WIDTH AS REQUIRED FOR TRUSS CONNECTION 16d TOENAILS @ EACH TRUSS r I a I; .1 r i n I tA DETAIL TRUSS FLOOR SYSTEM SPACING = 24" O.C. MAX ACTUAL SPACING BY OTHERS TOP CHORD BEARING FLOOR TRUSSES BY OTHERS AS REQUIREDIFOR ADDITIONADGER BEARING w/ (2> ROWS IOd NAILS @ 6" O,C, STAGGERED OR EXTEND ANCHOR BOLTS AS REQUIRED TO SUPPORT ADDITIONAL LEDGERS 1/k"O ANCHOR BOLTS w/ HEAVY DUTY WASHERS @ 12" O.C. STAGGERED Wt MIN. EMBED) OR SIMPSON ICFVL @ 48" D.C. w/ (6) SIMPSON D3 SCREWS 2 x 10 NO. 2 GRADE MIN. LEDGER BOARD BOTTOM CHORD BEARING TRUSS AND MID-CHORD BEARING TRUSS CONNECTIONS SIMILAR BEAR ON TOP OF LEDGER(S) 12006 MASTER INSULATED CONCRETE I ADVANCED WALL SYSTEMS, INC. FORM ABOVE GRADE WALL DRAWINGS 16927 231st AVENUE NW, BIG LAKE, MN 5309 LEDGER CONNECTIONS Phone: (763) 263-6512 Fax: (763) 263-5912 5201 East River Road Suile 308 Mlnneapolle,Mlnnexora 55921 Plwne: 763.5712500 Fax: 763.571 Bismarck -OetraX lakes Fargo Mirneapo4a S. Falk Vi www.ullep.mm engineers Drawn By: Troy DeGmt Clwcked By: Trevor Axner All. By: Crab Cri JOB SITE INFORWIlCiU (to be tilled out by Re contractarl C%x.: City: State: Zip Code'._ pro Date NUJand ,,1.2X SA-2B Dale'. Stree15: 5 of. 13 (16) 8d NAILS INTO BLOCKING WOOD FLOOR JOISTS BY OTHERS-' MANUFACTURED OR - MIN, 2 x 10 BLOCKING 2 72" O.C. IN FIRST (2) J131ST SPACES w/ (4) 8d TOE NAILS EACH END THESE DETAILS APPLY TO ABOVE GRADE WALLS ONLY ' DO NOT USE THESE DETAILS AT THE TOP OF BASEMENT WALLS. REFER TO THE BELOW GRADE PACKAGE FOR BASEMENT BLOCKING. (16) Bd NAILS INTO BLOCKING WOOD FLOOR TRUSSES J BY MANUFACTURER 2x4 BLOCKING T &B- OF TRUSSES IN FIRST (2) TRUSS SPACES E 72" O.C. w/ (4) ed TOE NAILS EACH END 1/2" PLYWOOD ONE SIDE- OF BLOCKING IN FIRST (2) TRUSS SPACES w/ (8> 8d NAILS TOP & BOTTOM ° v a ° k g ° k I , ?I ?"kg 8d NAILS E 6" O.C. I, MANUFACTURED 00 MIN. 2 x 10 NO, 2 GRADE LEDGER BOARD w% 1/2"0 ANCHOR BOLTS i w/ HEAVY DUTY :WASHERS l E 24" O.C. STAGGERED OR SIMPSON 1CFVLB 48" D.C. I% w/-(6) SIMPSON D3 SCREWS I. ° r" <I I r ? I v n" 1 ° Ifs, V I, gi v i I a I" v I/ ° J?° v I, ° CUT OUT FORM &'GROUT SOLID BEHIND LEDGER IF ANCHOR BOLTS ARE USED SEE SHEET SA-2 FOR WALL REINFORCEMENT REBAR NOT SHOWN . Bd NAILS 2 6" O.C. LOWER HALF OF! BLOCKING MAY BE OMITTED; IF FLOOR TO FLOOR HEIGHT IS LESS THAN 12' 2 x 4 LEDGER TOP & BOTTOM w/ Ve"O x 8" LONG ANCHOR BOLTS R 48" D.C. CUT OUT FORM II< GROUT SOLID BEHIND LEDGER L BOLTS SEE SHEET SA-2 FOR WALL REINFORCEMENT REBAR NOT SHOWN WALL SECTION PARALLEL TO FRAMING FLOOR JOISTS SHOWN AT TOP & TRUSSES SHOWN AT BOTTOM 2006 MASTER INSULATED CONCRETE ADVANCED WALL SYSTEMS, INC. FORM ABOVE GRADE WALL DRAWINGS 16927231st AVENUE NW, BIG LAKE, MN 55309 NON-BEARING WALL BLOCKING - Phone: (763) 263-6512 Fax: (763) 263-5912 5201 Eesi River goa0 S"Ite 3G6 5201 Ent Sh,a ibeat JOB SITE MF I I R Tl J O Rewaim Dale D¢so0plron l 55421 l by the on out y be filed contractor) Ila Phone: 763.571.2500 Fax: 763571 1168 p ner: Neiravd-Deaok Lakes-Fargp Minneapa,.Simx Falls wee: www.ultey.wm Seel Aa rate engineers De.. B Tro De3mM PialeolNSlMar: 2rt 1]99 y , CM1ecketl W TrevorAVner Approvep By: Craig OSwell Clly: Slale:_ Zip coca: Dale: Jenvary1.2006 SM1eels: 6 01l, 13 SA-3 NOTES 1. THESE DETAILS APPLY TO ALL FORM SIZES, 2, PLACE AN EXTRA #4 HORIZONTAL BAR IN THE BOTTOM OF ANY LINTELS LOCATED BELOW LEDGES. IN ADDITION, LINTELS BELOW LEDGES MUST HAVE SHEAR REINFORCEMENT. 3, LEDGES MAY BE PLACED ANYWHERE ALONG HEIGHT OF WALL PROVIDED GRADE IS NO GREATER THAN 8" ABOVE THE TOP OF THE LEDGER & WALL IS REINFORCED ASSUMING FULL HEIGHT GRADE. 4, REFER TO THE APPROPRIATE DETAILS FOR WALL REINFORCEMENT & LEDGER/FLOOR FRAMING CONNECTIONS. WALL REINFORCEMENT IS NOT SHOWN. 5. MAXIMUM ALLOWABLE BRICK HEIGHT IS 14 FEET, BRICK HEIGHT MAY BE UP TO 22 FEET IF LEDGE IN DETAILS 1 OR 2 IS REINFORCED SIM. TO DETAIL 3. 6. MAXIMUM FLOOR SPAN FOR DETAIL 03 IS 20 FEET, BRICK SLOPE GRADE ° AWAY FROM i? FOUNDATION .`. I1-111_ e 'i F.u 4" ICF e I BRICK LEDGE FORM OR 4" LEDGE w/ MIN. B"O HOLES TO CONCRETE PORTION @ 24" O.C. DETAIL 1 UNREINFORCED BRICK LEDGE @ ABOVE GRADE ICF MATERIALS CONCRETE; 3500 PSI @ 28 DAYS AGGREGATE; WALLS - 3/4" MAX REINFORCING ASTM A615 GRADE 60 WOOD FRAME BY OTHERS BRICK VENEI SLOPE GRADE AWAY FROM i' FOUNDATION el. ; I I-1 I I_ ? ;1111,111=1 l a A jO I 4" ICF BRICK LEDGE FORM OR 4" LEDGE w/ MIN. Bi10 HOLES TO CONCRETE PORTION @ 24" O.C. DETAIL ;2 UNREINFORCED BRICK LEDGE @ ABOVE GRADE WOOD FRAME CONTINUOUS 44 - HORIZONTAL BAR I ° I 1 , I y I I I e I' I I, le. I ° THE REINFORCER OR ° #4 HOOKS @ 24" O.C. w/ 130' BEND AROUND , CONTINUOUS a4 HORIZONTAL BAR IN LEDGE ° LAP HOOK 24" INTO WALL 6" 1CF -J BRICK LEDGE FORM OR 6" LEDGE w/ MIN. B"O HOLES TO CONCRETE PORTION DETAIL 3 @ 24" O.C. REINFORCED FLOOR LEDGE AT OR ABOVE GRADE 12006 MASTER INSULATED CONCRETE I ADVANCED WALL SYSTEMS, INC. I FORM ABOVE GRADE WALL DRAWINGS 16927 231st AVENUE NW, BIG LAKE, MN 55309 LEDGE DETAILS Phone! (763) 263-6512 Fax: (763) 263-591,2 5201 East River Road Suite 308 Minneapolis, Mlnn95oto 55121 Phone: 70 5712500 Fax: 763.571.1168 Beanara DelloAli es Fargo-Milneapolu Sbla Falk Web: www.ulleg.wnn engineers Drawn By: TroyO dol Checked By Trevor Amer Approved By: Craig Cbmal JOB SITE INFORMATION (to be filled out by the con°azlorl Owner: StualAddreas: Coae:_ Data Dale: Number: 2(15.1399 I /"? A _? Dale: Jdnua,v 1.211L6 $Ilbela: v`nu 1 01113 NOTES 1, HORIZONTAL REINFORCING IS TO BE CENTERED IN WALL & EXTEND A MINIMUM OF 24" PAST THE OPENING AT EACH END, 2,LINTELS THAT SPAN 4 FEET OR LESS & SUPPORT 2100 PLF OR LESS, OR LINTELS THAT SPAN 6 FEET OR LESS & SUPPORT 900 PLF OR LESS, DO NOT REQUIRE SHEAR REINFORCING, 3. ALL WALL OPENINGS ARE TO HAVE A MIN. OF 24" OF CONCRETE WALL BETWEEN THEM. ADJACENT 6-FOOT WIDE MAX, OPENINGS MAY HAVE A MINIMUM OF 12" OF CONCRETE WALL BETWEEN THEM, 4, PLACE AN ADDITIONAL (1) #5 BAR VERTICAL OR A TOTAL OF (1) "6 BAR VERTICAL FULL HEIGHT EACH SIDE OF ALL OPENINGS. 5r SEE SA-1 FOR FURTHER NOTES AND CONSTRUCTION GUIDELINES. 6, SPECIAL REVIEW 1S REQUIRED FOR LINTELS BEYOND THESE LIMITS. 7. LOADS SHOWN ARE IN ADDITION TO LINTEL SELFWEIGHT, "3 SHEAR RE1NF. - @ 8" O.C. MATERIALS CONCRETE; 3500 PSI @'28 DAYS AGGREGATE: WALLS - 3/4" MAX HORIZONTAL REINFORCEMENT: ASTM A615 GRADE 60 SHEAR REINFORCEMENT;': ASTM A615 GRADE 60 LOADS LIVE . LOAD: 42 PSF ROOF MAX, LIVE LOAD: 40 PSF FLOOR DEAD LOAD: 15 PSF ROOF DEAD LOAD 12 PSF FLOOR WIND LOAD: 90 MPH EXPOSURE B Z HORIZONTAL REBAR •" TOP & BOTTOM 4" PER TABLE MIN, TYPICAL CONCRETE LINTEL HORIZONTAL LINTEL SPAN IN FEET BARS T& B 4 5 6 7 8 9 10 12 (1) 45 5700 3600 2500 1800 1400 1000 800 600 <2> `4 6000 4600 3200 2300 1800 1400 1100 700 (1) #6 6000 5000 3500 2500 1900 1500 1200 800 (1) °7 OR (2) #5 6000 6000 4600 3400 2600 1900 1400 800 FOR 4" LINTELS 2006 MASTER INSULATED CONCRETE ADVANCED WALL SYSTEMS, INC. FORM ABOVE GRADE WALL DRAWINGS 16927 231st AVENUE NW, BIG LAKE, MN 55309 LINTEL SECTION AND REINFORCEMENT TABLE Phone: (763) 263-8512 Fax: (763) 263-5912 5201 East River Road SUire 3DB JOB SITE INFORMATION R¢m. Dale Oea?plion MiMeap0116, MInne3olB 55621 (100e filled out by the conlro,W) Phone: 763.571 2500 Fax: 7" 571.1168 Owner BGna1d1-Derallakes- FeryO. M6meeppks. Sian Fair, VAR, wwwLnteg.com Been Address: p` engineers Drawn By: TroyDeGroot ProleaNumbm:?2L.1 @. Checked By: ThnnrNrer - Approved By: Crag Oswel Ctry: Stale: ? Zlp Code: Dale: January 1. 2006 Shoals: eM 13 SA-5A t HORIZONTAL REINFORCING IS TO BE CENTERED IN WALL & EXTEND A MINIMUM OF 24" PAST THE .OPENING AT EACH END. 2, THE FOLLOWING TABLE COVERS ONLY LINTELS SUPPORTING A MAXIMUM OF 20 FEET OF ROOF LOADS AND NO WALL LOADS. IN ADDITION, THESE WALL OPENINGS ARE TO HAVE A MINIMUM OF 12i1 OF CONCRETE WALL BETWEEN THEM, 3, PLACE AN ADDITIONAL (1) 3$5 BAR VERTICAL OR A TOTAL OF (1) #6 BAR VERTICAL FULL HEIGHT EACH SIDE OF ALL OPENINGS. 4. SEE SA-1 FOR FURTHER NOTES AND CONSTRUCTI' GUIDELINES, 5. SPECIAL REVIEW IS REQUIRED FOR LINTELS BEYOND THESE LIMITS. 6. LOADS SHOWN ARE IN ADDITION TO LINTEL SELFWEIGHT, a3 SHEAR REINF, @ 6" O.C. HORIZONTAL REBAR TOP & BOTTOM PER TABLE MATERIALS CONCRETE; 3500 PSI @ 28 DAYS AGGREGATE; WALLS - 3/4 MAX HORIZONTAL REINFORCEMENT; ASTM A615 GRADE 60 SHEAR REINFORCEMENT; ASTM A615 GRADE 60 S LIVE LOAD; 42 PSF ROOF iMAX, DEAD LOAD; 15 PSF ROOF WIND LOAD; 90 MPH EXPOSURE B 4'k MIN. F FRAMING OTHERS LINTEL SPAN IN FEET HORIZ. REBAR REQUIRED SHEAR REINF. REQUIRED 3 (1) a5 NONE 4 (1) 45 YES 5 (1) 45 YES 6 (1) #5 YES 2006 MASTER INSULATED CONCRETE FORM ABOVE GRADE WALL DRAWINGS LINTEL SECTION AND REINFORCEMENT TABLE 5201 Eon RWer Road SW. XG Minneapolle. WiloesDla 55421 Phone: 7635712500 Fu: 761571.1168 o tGVreapeks S"ux Falk loom web. k "Winn.uheeig.mm Web; www engineers Orawn By: Troy D6Oroon Checked B, 71e AXW ANWwed ByCrag Oswek ADVANCED WALL SYSTEMS, I 16927231st AVENUE NW, BIG LAKE, MN 5 Phone: (763) 263-8512 Fax: (763) 263-59 JOB SITE INFORMATIIX4 (lo be lined me by the conlraclor) Slreet Address' CIfY Slala:-zip COtle:_ Project NUpber: SA-5B Dater January 1. 2CG6 Sbeels: 9 of 13 NOTES 1, HORIZONTAL REINFORCING IS TO BE CENTERED IN WALL & EXTEND A MINIMUM OF 24" PAST THE OPENING AT EACH END. 2.LINTELS THAT SPAN 6 FEET OR LESS & SUPPORT 6000 PLF OR LESS DO NOT REQUIRE SHEAR REINFORCING, 3. ALL WALL OPENINGS ARE TO HAVE A MIN, OF 24" OF CONCRETE WALL BETWEEN THEM, ADJACENT 6-FOOT WIDE MAX, OPENINGS MAY HAVE A MINIMUM OF 12" OF CONCRETE WALL BETWEEN THEM, 4. PLACE AN ADDITIONAL (1) #5 BAR VERTICAL OR A TOTAL OF (1) °6 BAR VERTICAL FULL HEIGHT EACH SIDE OF ALL OPENINGS, 5, SEE SA-1 FOR FURTHER NOTES AND CONSTRUCTION GUIDELINES, 6, SPECIAL REVIEW IS REQUIRED FOR LINTELS BEYOND THESE LIMITS, 7, LOADS SHOWN ARE IN ADDITION TO LINTEL SELFWEIGHT, (1) #5 HORIZONTAL BAR @ TOP & CENTER I y OF LINTEL #3 S-HOOK SHEAR REINF, I < ° @ is" D.C. HORIZONTAL REBAR @ BOTTOM OF LINTEL MATERIALS CONCRETE: 3500 PSI @ 28 DAYS AGGREGATE: WALLS - 3/4" MAX HORIZONTAL REINFORCEMENT: ASTM A615 GRADE 60 SHEAR REINFORCEMENT: ASTM A615 GRADE 60 LOADS, LIVE LOAD: 42 PSF ROOF MAX. LIVE LOAD: 40 PSF FLOOR DEAD LOAD:15 PSF ROOF DEAD LOAD:12 PSF FLOOR WIND LOAD: 90 MPH EXPOSURE B I? z f I (U (U m SEE TABLE 4" MIN. TYPICAL CONCRETE LINTEL HORIZ LINTEL SPAN IN FEET BARS 4 5 6 7 8 9 10 12 14 16 18 (1)"1 6000 6000 4700 3400 2500 1900 1500 1000 700 400 300 (1)a6 6000 6000 6000 4800 3700 2600 2300 1500 1100 800 600 FOR 4" AND THICKER LINTELS 2006 MASTER INSULATED CONCRETE ADVANCED WALL SYSTEMS, INC. FORM ABOVE GRADE WALL DRAWINGS 16927 231st AVENUE NW, BIG LAKE, MN 55309 LINTEL SECTION AND REINFORCEMENT TABLE Phone: (763) 263-8512 Fax: (763) 263-5912 5201 East River Road Suite 300 JOB SITE INFORMATION Ruvislon Dale DeSCripven Ito W filled out by the contracmrl Minneapolis, Minnesota SE121 Phone ]63571.2500 Fax_ 764571.1168 Owner. Bsmardl - DeOdt takes-Fargo Murree dell. Sioux Falb W.: www.ulleg.cnm Street Address: 'I engineers DrewnBy TroyDecrool ProtectNOmher: ClwckBd By, ToWor Mau: - Data January 1. 20% SA-5C Approval By: Crag OSwNI C,ry: Slate- Zip Coder Sneers: too i3 NOTES 1. HORIZONTAL REINFORCING IS TO BE CENTERED IN WALL & EXTEND A MINIMUM OF 24" PAST THE OPENING AT EACH END. 2.LINTELS THAT SPAN 4 FEET OR LESS & SUPPORT 3000 PLF OR LESS, OR LINTELS THAT SPAN 6 FEET OR LESS & SUPPORT 1200 PLF OR LESS, DO NOT REQUIRE SHEAR REINFORCING, 3. ALL WALL OPENINGS ARE TO HAVE A MIN. OF 24" OF CONCRETE WALL BETWEEN THEM, ADJACENT 6-FOOT WIDE MAX. OPENINGS MAY HAVE A MINIMUM OF 12" OF CONCRETE WALL BETWEEN THEM, 4. PLACE AN ADDITIONAL (1) 45 BAR VERTICAL OR A TOTAL OF (1) 06 BAR VERTICAL FULL HEIGHT EACH SIDE OF ALL OPENINGS. 5. SEE SA-1 FOR FURTHER NOTES AND CONSTRUCTION GUIDELINES. 6, SPECIAL REVIEW IS REQUIRED FOR LINTELS BEYOND THESE LIMITS. 7r LOADS SHOWN ARE IN ADDITION TO LINTEL SELFWEIGHT. "3 SHEAR RE1NF, @ 12" O.C. MATERIALS CONCRETE; 3500 PSI @ 28 DAYS AGGREGATE; WALLS - ?/4" MAX HORIZONTAL REINFORCEMENT; ASTM A615 GRADE 60 SHEAR REINFORCEMENT;: ASTM A615 GRADE 60 LOADS LIVE LOAD; 42 PSF ROOF MAX. LIVE LOAD; 40 PSF FLOOR DEAD LOAD; 15 PSF ROOF DEAD LOAD; 12 PSF FLOOR WIND LOAD; 90 MPH EXPOSURE B HORIZONTAL REBAR TOP & BOTTOM 51/2rl PER TABLE MIN, TYPICAL CONCRETE LINTEL HORIZONTAL LINTEL SPAN IN FEET BARS T& B 4 5 6 7 8 9 10 12 14 16 18 (1) 05 5800 3700 2500 1800 1400 1100 800 500 400 200 200 (2) #4 6000 4700 3200 2300 1800 1400 1100 700 500 300 200 (1) n6 6000 5700 3500 2600 1900 1500 1200 800 600 400 200 OR1( a2)7u5 6000 6000 4100 3500 2600 2100 1600 1000 600 400 200 FOR 6" AND THICKER LINTELS S, INC. ADVANCED WAL 2006 MASTER INSULATED CONCRETE MN 55309 16927 231st AVENUE NW FORM ABOVE GRADE WALL DRAWINGS Phone: (763) 263 -8512 3-591'le, LINTEL SECTION AND REINFORCEMENT TABLE nommo? JOB SITE INFORMATION le De?iDUan 5201 East River Road Suite 30B ito be filled oel by the conted.1) gid MimnaarAIS.Knnesola `3121 pMne: 7 571,2500 Fax: 763.571.1168 OwnIX: Bismar6F Delmn LaFes Fa,, Arveapolt -SloopFalk Web: www,Whr9.c= Sheer Adbre66'. a : 2 5 engineers Drawn By: TroyDe2loWt uarvL20dE SA-5D By: Trevor Arner Cheo,ed Cily. Stater ZIa CnCe: fl of {3 ; j AlooveE By: crag OSwatl l NOTES, 1. HORIZONTAL REINFORCING IS TO BE CENTERED IN WALL & EXTEND A MINIMUM OF 24" PAST THE OPENING AT EACH END. 2r THE FOLLOWING TABLE COVERS ONLY LINTELS SUPPORTING A MAXIMUM OF 20 FEET OF ROOF LOADS AND NO WALL LOADS. IN ADDITION, THESE WALL OPENINGS ARE TO HAVE A MINIMUM OF 12" OF CONCRETE WALL BETWEEN THEM. 3r PLACE AN ADDITIONAL (1) #5 BAR VERTICAL OR A TOTAL OF (1) #6 BAR VERTICAL FULL HEIGHT EACH SIDE OF ALL OPENINGS, 4. SEE SA-1 FOR FURTHER NOTES AND CONSTRUCTION GUIDELINES. 5. SPECIAL REVIEW IS REQUIRED FOR LINTELS BEYOND THESE LIMITS. 6, LOADS SHOWN ARE IN ADDITION TO LINTEL SELFWEIGHT, a3 SHEAR REINF. @ 8" O.C. MATERIALS CONCRETE: 3500 PSI @ 28 'DAYS AGGREGATE: WALLS - 3/4" MAX HORIZONTAL REINFORCEMENT: ASTM A615 GRADE 60 SHEAR REINFORCEMENT: ASTM A615 GRADE 60 LOADS LIVE LOAD: 42 PSF ROOF MAX. DEAD LOAD: 15 PSF ROOF WIND LOAD: 90 MPH EXPOSURE B v Z f - b? ROOF FRAMING BY OTHERS HORIZONTAL REBAR? f1' "1 -4- 51/2" & BOTTOM 51/2" PER TABLE MIN, TYPICAL CONCRETE LINTEL LINTEL SPAN IN FEET HORIZ, REBAR REQUIRED SHEAR REINF, REQUIRED 3 (1) 45 NONE 4 (1) #5 NONE 5 (1) #5 YES 6 (1) "5 YES 2006 MASTER INSULATED CONCRETE ADVANCED WALL SYSTEMS, INC. FORM ABOVE GRADE WALL DRAWINGS 16927231st AVENUE NW, BIG LAKE, MN 55309 LINTEL SECTION AND REINFORCEMENT TABLE Phone: (763) 263-8512 Fax: (763) 263-5912 5201 East River Road Suite 309 Mlnneapolie, Minnesola 55421 Phone: 153.571.2500 Far 763.571.1168 Bsroarak Dreol Lakes Fargo M'mreeydis Sser Fals Web: www.ulleig.¢ engineers prawn 8y: Trey OeG. Ctleaked By: Taw. A.. APWOVed By: Crae,OSVdl JOB SITE INFORMATION (to be Treed out by the Conlromr) Sead Dia. Number: 1M 1399 2066 SA-5E Gale: Jan ua,v 2W6 $M1eelc: 1201 13 I- UK b HNU I M1l.KLK LIN 1 LLJ 1, HOR ZONTAL REINFORCING IS TO BE CENTERED IN WALL & EXTEND A MINIMUM OF 24'1 PAST THE OPENING AT EACH END. 2. LINTELS THAT SPAN 8 FEET OR LESS & SUPPORT 5000 PLF OR LESS DO NOT REQUIRE SHEAR REINFORCING. 3. ALL WALL OPENINGS ARE TO HAVE A MIN. OF 24" OF CONCRETE WALL BETWEEN THEM. ADJACENT 6-FOOT WIDE MAX, OPENINGS MAY HAVE A MINIMUM OF 12" OF CONCRETE WALL BETWEEN THEM. 4, PLACE AN ADDITIONAL (1) #5 BAR VERTICAL OR A TOTAL OF (1) #6 BAR VERTICAL FULL HEIGHT EACH SIDE OF ALL OPENINGS, 5, SEE SA-1 FOR FURTHER NOTES AND CONSTRUCTION GUIDELINES. 6. SPECIAL REVIEW 1S REQUIRED FOR LINTELS BEYOND THESE LIMITS. 7, LOADS SHOWN ARE IN ADDITION TO LINTEL SELFWEIGHT, (1) a5 HORIZONTAL BAR @ TOP OF LINTEL 1 v a I' r F f" I> I #3 S-HOOK ? I° I. SHEAR REINF, ?< al @ 18" O.C. HORIZONTAL REBAR @ BOTTOM OF LINTEL .+ SEE TABLE 51/2 " MIN. MATERIALS CONCRETE; 3500 PSI @ 28 DAYS AGGREGATE; WALLS - 3/4'1 MAX HORIZONTAL RASNM A615 GRADE 60 SHEAR REINFORCEMENT; ASTM A615 GRADE 60 1nADS LIVE LOAD; 42 PSF ROOF MAX, LIVE LOAD; 40 PSF FLOOR DEAD LOAD;I5 PSF ROOF DEAD LOAD; 12 PSF FLOOR WIND LOAD; 90 MPH EXPOSURE B z f (U (U M LINTEL SPAN IN FEET 4 5 6 7 8 9 10 12 14 16 18 :15 16000 16000 14700 13400 12500 11900 11500 11000 1 700 1 400 1300 I(2)" 5I 6000 16000 16000 16000 15200 14100 13300 12200 11600 11100 1 800 ALLOWABLE ACTUAL LINTEL LOAD IN I FOR 6" AND THICKER LINTELS 2006 MASTER INSULATED CONCRETE ADVANCED WALL SYSTEMS, 16927 231st AVENUE NW, BIG LAKE, MN FORM ABOVE GRADE WALL DRAWINGS Phone: (763) 263-8512 Fax: (763) 263-5 LINTEL SECTION AND REINFORCEMENT TABLE 5201 Easl Rrver Road Spne 306 Minneapolis. Minneaole 55421 Plwne: 7635M2500 Fax: 763.571.1168 Namara, - DiMeM takee - Fargo Mnneapare - S v Fee Web'. www.Ulteip.com engineers Drawn By: Troy DeGloot Checked By: Trevor Amer Approved By: Cray Cswe4 JOB SITE INFORMATION ?t0 pa 11110 bin by Me con'bran) Street AtldRea'. D.W NUmoae: 2011399 Delel January L 2006 SA-5F 13 City: Slater Zlp Cotle:_ Sheets: 13 OF DRAWING INDEX SB-1A j? INDEX & CERTIFICATION , IDELINES ES rz SB-1C GENERAL NOTES SB-1D STRIP FOOTING TABLES ? SB-2A WALL SECTION - SAND BACKFILL (BELOW GRADE I.C.F. ONLY) ? W--2B WALL SECTION - SANDY-CLAY BACKFILL (BELOW GRADE I.C.F. ONLY) SB-2C WALL SECTION - CLAY BACKFILL (BELOW GRADE I.C.F. ONLY) ? SB-3A WALL SECTION - SAND BACKFILL (FULL HEIGHT I.C.F.) Q SB-3B WALL SECTION - SANDY-CLAY BACKFILL (FULL HEIGHT I.C.F.) ? SB-3C WALL SECTION - CLAY BACKFILL (FULL HEIGHT I.C.F.) ? SB-4A FOUNDATION WALL REINFORCEMENT TABLE (ACTUAL THICKNESS) ? SB-4B FOUNDATION WALL REINFORCEMENT TABLE (NOMINAL THICKNESS) ? SB-5A LOOKOUT WALL SECTION ? SB-56 FROST WALL SECTION ? SB-6 JUMP-FOOTING DETAIL ? SB-7A NON-BEARING WALL BLOCKING SECTION (BELOW GRADE I.C.F. ONLY) ? SB-7B NON-BEARING WALL BLOCKING SECTION (FULL HEIGHT I.C.F.); ? SB-8A LINTEL SECTION AND REINFORCEMENT TABLE ? SB-813 LINTEL SECTION AND REINFORCEMENT TABLE ? SB-9 WINDOW WELL SECTION I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Professional Engineer under the laws of the States of Minnesota & Wisconsin. Print Name: CRAIG L. OSWELL Signed:", Date: 01/01/06 MN License Number: 42341 WI License Number: E-37911 CRAIG L. MN 2006 MASTER INSULATED CONCRETE ADVANCED WALL SYSTEMS, INC. FORM BELOW GRADE WALL DRAWINGS 16927 231st AVENUE NW. BIG LAKE, MN 55309 INDEX & CERTIFICATION Phone' (763) 263-8512 Fax: (763) 283-591'.2 5201 East Piuar Rpad SA.908 Kl apotis. Minnesota 55421 Phone: 7635712500 Fax: 763.571.1188 Bismarck DeadLLaYS-Fargo Mlnneaaoli;-Sioux Falls Wept ww.v.ulleig.wm engineers D,ewnsy T,ovoeorot Cher e88y: Trevor Axner Ap.10Syr C1a10s aal JOB SITE INFORMATION Ilo Oe fillet 0u1 by the fAnwacaon Sveet AGNess' City Stab, _ zip 000e:_ Pmleq Nartber'. 2p6.1353 Janun,v 1.201M Sale: SB-1A Sneels: 1 d'20 DRAWING SCOPE & USE GUIDELINES SCOPE OF WORK THESE YEAR 2006 INSULATED CONCRETE FORM (I.C.F.) BELOW GRADE WALL DRAWINGS, CONSISTING OF SB-1 THROUGH SB-9 AND DATED 1-1-06, ARE PREPARED BY ULTEIG ENGINEERS, INC. THESE DRAWINGS CONTAIN STRUCTURAL DESIGN INFORMATION AND DETAILS TO BE USED IN THE CONSTRUCTION OF I.C.F. BELOW GRADE WALLS FOR VARIOUS CONDITIONS COMMON WITHIN THE RESIDENTIAL MARKET ONLY. THE INFORMATION IS INTENDED FOR THE I.C.F. CONTRACTOR, AS WELL AS THE GENERAL CONTRACTOR AND THE FRAMING CONTRACTOR. THESE DRAWINGS ARE CERTIFIED AND PREPARED TO THE REQUIREMENTS OF THE INTERNATIONAL RESIDENTIAL CODE (IRC), AS WELL AS THOSE OF THE MINNESOTA AND WISCONSIN STATE BUILDING CODES. THESE DRAWINGS ARE VALID THROUGH DECEMBER 31, 2006. THESE DRAWINGS ARE LICENSED THROUGH AN AGREEMENT BETWEEN ULTEIG AND THE LICENSEE NOTED IN THE TITLE BLOCK BELOW. THESE DRAWINGS ARE TO BE USED SOLELY FOR PROJECTS IN WHICH THE LICENSEE IS DIRECTLY RESPONSIBLE. THESE DRAWINGS MAY BE RELEASED BY THE LICENSEE TO ITS AUTHORIZED AGENTS FOR THE USE IN PROCUREMENT OF BUILDING PERMITS AND CONSTRUCTION INVOLVING THE LICENSEE'S I.C.F. INSTALLATION ONLY. ALL OTHER USES ARE PROHIBITED. USE GUIDELINES FOR EACH PROJECT, THE LICENSEE IS TO INDICATE THE APPLICABLE SHEETS OF THE DRAWINGS ON THE INDEX SHEET AND THEN SUBMIT THEM WITH THE FULL CONSTRUCTION DOCUMENT PACKAGE TO THE APPROPRIATE CITY BUILDING DEPARTMENT AT THE TIME OF PERMIT APPLICATION OR IN ACCORDANCE WITH AN ALTERNATIVE METHOD APPROVED BY THE CITY. THE CITY BUILDING INSPECTIONS DEPARTMENT WILL REVIEW THE DRAWINGS AND USE THEM DURING INSPECTIONS TO ENSURE COMPLIANCE. THESE DRAWINGS ARE PRIMARILY APPLICABLE TO THE FOLLOWING CONDITIONS!: 1. BELOW GRADE WALLS TEN FEET OR LESS IN HEIGHT 2. OVERALL BUILDING HEIGHT NOT EXCEEDING TWO STORIES PLUS A BASEMENT 3. FLOOR SPANS NOT EXCEEDING TWENTY FEET CLEAR (ELSE ADJUST LEDGER CONNECTIONS AND FOOTING SIZES AS REQUIRED) 4. WOOD JOIST, LUMBER, OR TRUSS FLOOR AND ROOF SYSTEMS SPECIAL CONSIDERATION AND DESIGN MAY BE REQUIRED FOR CONDITIONS BEYOND THESE LIMITS. 2006 MASTER INSULATED CONCRETE ADVANCED WALL SYSTEMS, INC. FORM BELOW GRADE WALL DRAWINGS 16927231st AVENUE NW, BIG LAKE, MN 55309 SCOPE & USE GUIDELINES Phone: (763) 263-8512 Fax: (763) 263-5912 5201 East Rlver Road Suite 308 Minneapolis. Mtraerdta 55,121 Phone: 763571,25W Fax: 763 we BismuG DeINX Lakes Fla,D Mlnnet,,dis- SIWr Few Web: wwwA09cotn engineers Drnwn By: Troy DaG,. Cheaed By: Trevor Axner ApptoveE By: Crag oewed JOB SITE INFORMATION Bp be filled out by the contractor) Owner. Street AdOress! I ProieaNmnber: 34i!?26. SB-1 B Oate: JenYdry 1,2006 City: Slaw: Zip co'.: Sheets: 2 o Ip GENERAL STRUCTURAL NOTES NOTES 1. THESE DRAWINGS APPLY TO FOUNDATION WALLS 10'-0" OR LESS IN HEIGHT FROM THE TOP OF SLAB (T.O.S.) TO THE TOP OF WALL (T.O.W.). BUILDING HEIGHT IS NOT TO EXCEED TWO STORIES PLUS A BASEMENT. FOR LEDGER CONNECTIONS, ANCHOR SPACING SHOWN IS BASED ON A MAXIMUM FLOOR SPAN OF 20 FOOT CLEAR. IF FLOOR SPANS ARE IN EXCESS OF THIS DISTANCE OR IF ADDITIONAL LOADING SUCH AS LIGHT WEIGHT CONCRETE TOPPING ARE APPLIED, DECREASE LEDGER CONNECTION SPACING (ANCHOR BOLTS OR ICFVL'S) PROPORTIONALLY. 2. THESE DETAILS APPLY EQUALLY TO THE 6" AND GREATER FORMS, UNLESS SPECIFICALLY NOTED'OTHERWISE. CONCRETE WIDTHS ARE ACTUAL DIMENSIONS. 3. WALLS ARE NOT TO BE BACKFILLED UNTIL THE CONCRETE HAS REACHED A COMPRESSIVE STRENGTH SUFFICIENT TO SUPPORT ALL DESIGN LOADS. 4. HORIZONTAL WALL REINFORCING, UNLESS NOTED, CAN BE PLACED ANYWHERE WITHIN THE WIDTH OF THE WALL, ASSUMING MINIMUM COVER REQUIREMENTS ARE MET. PER ACI 318 CHAPTER 7, MINIMUM CLEAR COVER IS %". 5. SPLICES NEED NOT BE TIED PROVIDED BAR CENTERLINES ARE WITHIN 2 INCHES OF EACH OTHER. ALL BAR SPLICES SHOULD BE A MINIMUM OF 48 BAR DIAMETERS. 6. REINFORCING BARS MAY BE BUNDLED UP TO THREE TO A BUNDLE. 7. STRIP FOOTINGS MAY BE PLACED AT AN ELEVATION LOWER THAN SHOWN IN THE DETAILS TO PROVIDE ADEQUATE FROST COVER OR ADEQUATE SOIL BEARING, WHEN REQUIRED. 8. UNLESS SPECIFICALLY NOTED, DOWELS MAY BE DRILLED AND SNUGGLY FIT IN PLACE. DOWELS DO NOT NEED TO BE TIED TO THE VERTICAL STEEL. 9. PLACE BARS SUCH THAT THEIR FINAL POSITION IS WITHIN %" OF THAT SHOWN IN THE DETAILS. TYING OF BARS IN PLACE IS NOT REQUIRED PROVIDED SUFFICIENT CARE IS TAKEN TO ENSURE THE BARS DSO NOT MOVE OUT OF TOLERANCE POSITION AND ALL CLEAR COVER REQUIREMENTS ARE MET. 10. PROVIDE MATCHING HOOK BARS FOR ALL HORIZONTAL BARS AT ALL WALL CORNERS AND INTERSECTIONS. LAP ALL HOOKS AND HORIZONTAL BARS PER NOTE 5. HORIZONTAL BARS MAY BE CONTINUOUS AND BENT AROUND CORNERS IN PLACE OF HOOKS. 11. FLOOR JOISTS AND TRUSSES ARE TO BEAR A MINIMUM OF 3%" ON SILL PLATE AT TOP OF WALL. INSTALL CONTINUOUS RIM BOARD AND CONNECTORS AS SHOWN IN DETAILS. CENTER OF ANCHOR BOLTS MUST BE 2%" FROM EDGE OF SILL PLATE OR CONCRETE WALL. INCREASE SILL PLATE SIZE AS NEEDED. 12. THE CENTER OF FOOTINGS MAY BE OFFSET UP TO 1" FROM THE CENTER OF THE WALL BEFORE SPECIAL REVIEW IS REQUIRED. 13. SLOPE GRADE AWAY FROM FOUNDATIONS A MINIMUM OF 6" WITHIN THE FIRST 10 FEET OR PROVIDE ADEQUATE DRAINS OR SWALES TO ENSURE SUFFICIENT DRAINAGE AWAY FROM THE STRUCTURE.' 14. SILL PLATES DO NOT NEED TO BE TREATED IN ACCORDANCE WITH IRC SECTION 323. ULTEIG RECOMMENDS INSTALLING A VAPOR BARRIER BETWEEN THE SILL AND TOP OF CONCRETE WALL. 12006 MASTER INSULATED CONCRETE I ADVANCED WALL SYSTEMS, INC. I FORM BELOW GRADE WALL DRAWINGS 16927 231st AVENUE NW, BIG LAKE, MN 55309 GENERAL NOTES Phone: (763) 2638512 Fax: (763) 263-591,2 5201 East Rlver Road Sulk 908 Mlnneap011e.awnnaeol. 55421 Phone: 76&571.2500 Fax: 70,571 110 Bismarck-DdniftlAna-FmW.Mixmpofc-So Farb Web: www.ulteig.wm ee 11 l engineers Drawn By: TroyD h,oi } x. Checxed By: Trevor Axner Approved By: Csalg Oewell JOB SITE INFORMATION (to be lolled out by the contractor) Street .city: state: ? Zip Ceder Didecl NUnnu T. ' SB Date: Januan 1 . 2Q08 S?/_ 1 C SM1e01s: _ 9 Mi20 MATERIALS CONCRETE: 2500 PSI @ 28 DAYS AGGREGATE: FTG - 11/2" MAX TABLE 1; FULL-HEIGHT I.C.F. TABLE 2; BELOW-GRADE I.C.F. WOOD-FRAMED ABOVE CONCRETE STRIP FOOTING TABLE STRUCTURE HEIGHT FULL HEIGHT BRICK VENEER FOOTING SIZE 1 FLOOR SYSTEM + ROOF NO 20" x 8" 1 FLOOR SYSTEM + ROOF YES 2 x " 2 FLOOR SYSTEMS + ROOF NO 28" x 1 2 FLOOR SYSTEMS + ROOF YES 30' x 10 NON-BEARING ALL LEVELS NO 20" x 8" NON-BEARING ALL LEVELS YES 22" x B" CONCRETE STRIP FOOTING TABLE STRUCTURE HEIGHT FULL HEIGHT BRICK VENEER FOOTING SIZE 1 FLOOR SYSTEM + ROOF NO 16" x 8" 1 FLOOR SYSTEM + ROOF YES 18" x 8" 2 FLOOR SYSTEMS + ROOF NO 20" x B" 2 FLOOR SYSTEMS + ROOF YES 22" x 8" NOTES 1, A FLOOR SYSTEM PERTAINS TO WOOD TRUSSES, JOISTS, OR LUMBER - SPANNING A MAXIMUM OF 20 FEET, 2. A ROOF PERTAINS TO WOOD TRUSSES SPANNING A MAXIMUM OF 40 FEET. BONUS ROOMS ARE TO BE CONSIDERED A FLOOR SYSTEM, 3. VENEER MAY BE UP TO 22 FEET IN HEIGHT, VENEER MAY BE BRICK OR STONE, BUT MUST BE A MAXIMUM THICKNESS OF 4 INCHES. 4. FOOTING SIZES APPLYING TO STRUCTURES WITHOUT FULL HEIGHT VENEER MAY STILL HAVE UP TO SIX FEET OF VENEER FOR THESE SIZES. 5, FOOTING SIZES SHOWN ARE LABELED AS 'WIDTH' x 'DEPTH' x CONTINUOUS.: 6. ABOVE GRADE I.C.F. 1S ASSUMED TO BE A MAXIMUM OF 6" THICK CONCRETE! PORTION, BELOW GRADE I.C.F. 1S ASSUMED TO BE A MAXIMUM OF 10" THICK CONCRETE PORTION. 7, ALL FOOTING SIZES ARE BASED ON AN ASSUMED ALLOWABLE SOIL BEARING', CAPACITY OF 2000 PSF. INCREASE OR DECREASE FOOTING WIDTH AS REQUIRED FOR SPANS AND CONDITIONS VARYING FROM THESE ASSUMPTIONS. CONCRETE STRIP FOOTING TABLES 2006 MASTER INSULATED CONCRETE ADVANCED WALL SYSTEMS, INC. FORM BELOW GRADE WALL DRAWINGS 16927 231 si AVENUE NW, BIG LAKE, MN 55309 STRIP FOOTING TABLES Phone: (763) 263-8512 Fax: (763) 263-5912 5201 East Filter Roatl Stale 900 JOB SITE INFORMATION Revision Data Dmcnptm E Minneapolis. Mlnnesota 55921 (to DB tllldpul by lM1e convador7 PM1ane: 2571.2500 Fax: 763.5711166 Omer 6iPNnk Detal kJams-Fall - Miveapas - Soux Falk Web: w.ew Wap mm Street Address' engineers Drawn By: Troy Del Project NOmbar: 405.1399 Ctml By: Trav«Axner Dare. Jail 1. 2006 SB-1 D Apprm dBy: Crag OSwell Cily: Stale:.Zip Cmm: SbeM 4 o1120 NOTES 1. PRIOR TO BACKFILLING, FOUNDATION WALLS MUST BE LATERALLY SUPPORTED BY FLOOR CONSTRUCTION AT TOP & SLAB AT BOTTOM OR BY ADEQUATE TEMPORARY BRACING. 2. SPECIAL REVIEW 1S REQUIRED FOR WALLS HIGHER THAN 10'-0" T.O.S. TO T.O.W. 3. SEE SB-4 FOR PLACEMENT OF VERTICAL REBAR. 4. PROVIDE A MINIMUM OF TWO ANCHORS PER SECTION OF SILL PLATE, AS WELL AS AN ANCHOR WITHIN 12" OF EACH END. 5, DRAIN TILE, DAMPROOFING AND/OR WATERPROOFING, & INSULATION, AS WELL AS THEIR INSTALLATION, ARE TO BE IN ACCORDANCE WITH THE CODE. 6, SEE SB-1 FOR FURTHER NOTES AND CONSTRUCTION GUIDELINES. MATERIALS CONCRETE (28 DAYS): 3500 PSI AGGREGATE: FOOTING - 11/2" MAX WALLS - 3/4" MAX REINFORCING: ASTM A615 GRADE 60 BACK 100 % GRANULAR - GROUP 1 FILL: EQUIVALENT FLUID PRESSURE (Yeq) = 30 PCF GROUPS BASED ON THE CODE 1/2"0 x 10" LONG ANCHOR BOLTS w/ (1) NUT & HEAVY DUTY WASHER (711 MIN, EMBED)' E 60" O.C. OR SIMPSON MAB15 OR APPROVED EQUAL 8 24" O.C. -\ SLOPE GRADE AWAY FROM FOUNDATION ?-. I 1=I I I- 1, I I' I I, n ? I I I y "4 HORIZONTAL ' BARS 2 48 O.C. i w I 1 1 y VERTICAL STEEL , SEE SB-4 f ICF FLAT of FORM WALL a P c 44 x 2'-0" DOWELS L R 4B" O.C. " = MIN, EMBED) (5 r ?R J J CUT OUT FOAM i° I 3 R SLAB FOR 6" SLAB ON EVERY 24" & i GRADE PLACE 04 x 2'-0' DOWELS 11 72" O.C. (5'1 MIN, EMBED) ^. ° CONCRETE STRIP FOOTING' SEE SHEET SB-1D JOIST HANGER (USP W MLL JLL 111111 OR SIMPSON) w/ (4) IOd x 11/E" NAILS TO PLATE & NO NAILS TO 2 x 4 MIN. CONTINUOUS JOIST Iff RIBBON BRACE ?-SIMPSON A35 ANCHOR w/ (4) 8d x 11/2" NAILS EACH LEG 2x6 MIN, WOOD EITHER SIDE OF TRUSS SILL PLATE 2 x 6 MIN. WOOD SILL PLATE t--m1ST OR LL?Q FLCrii SYSTEM SPACING = 24i1 O.C. MAX ACTUAL SPACING BY OTHERS 2006 MASTER INSULATED CONCRETE FORM BELOW GRADE WALL DRAWINGS WALL SECTION - SAND BACKFILL TRUSS OM SYSTEM SPACING = 24" O.C. MAX ACTUAL SPACING BY OTHERS 5201 East River Roatl Sune 306 Minneapolis. Minnesota 55421 Phone: 763.5712500 Fab: 763.571.1166 PiSmartA Darr it LaMrti Mlninaglil-Som Ftlls Wac: w.w.unelsmin engineers Drawn By: Troy Dei Cinexion By: Trevor Axnel Approved By: Clap Oav¢II ADVANCED WALL SYSTEMS, INC. 16927231st AVENUE NW, BIG LAKE, MN 55309 .Phone: (763) 263-8512 Fax: (763) 263-5912 JOB SITE INFORMATKM4 (ID be filled out by the mnirBi Owne: Spent Amre¢¢: Dale I eq at' 2?txa' /\1"1/51 '11y: State Zlp GDtl¢: PeoDale:l JanuarvL2006 -LH _ Snoods: 5 of 120' J7?,.,(/ NOTES 1, PRIOR TO BACKFILLING, FOUNDATION WALLS MUST BE LATERALLY SUPPORTED BY FLOOR CONSTRUCTION AT TOP & SLAB AT BOTTOM OR BY ADEQUATE TEMPORARY BRACING. 2r SPECIAL REVIEW IS REQUIRED FOR WALLS HIGHER THAN 10'-0" T.O.S. TO T.O.W. 3. SEE SB-4 FOR PLACEMENT OF VERTICAL REBAR. 4, PROVIDE A MINIMUM OF TWO ANCHORS PER SECTION OF SILL PLATE, AS WELL AS AN ANCHOR WITHIN 12" OF EACH END. 5. DRAIN TILE, DAMPR13OFlNG AND/OR WATERPROOFING, & INSULATION, AS WELL AS THEIR INSTALLATION, ARE TO BE IN ACCORDANCE WITH THE CODE. 6r SEE SB-1 FOR FURTHER NOTES AND CONSTRUCTION GUIDELINES- MATERIALS CONCRETE (28 DAYS); 3500 PSI AGGREGATE: FOOTING - 11/Q" MAX WALLS - 3/4" MAX REINFORCING: ASTM A615 GRADE 60 BACK GRANULAR & LIGHTCLAY - GROUP 11 FILL: EQUIVALENT FLUID PRESSURE (Yeq) = 45 PCF GROUPS BASED ON THE CODE 112"0 x 10" LONG ANCHOR BOLTS w/ (1), NUT & HEAVY DUTY WASHER (T' MIN, EMBED) @ 36" O.C. OR SIMPSON MAB15 OR APPROVED EQUAL @ 16" O.C. --\ SLOPE GRADE AWAY FROM FOUNDATION 8r' I° MIN I l l=III-1 % I I I I I° I I I #4 HORIZONTAL 'i BARS @ 48" D.C. r I I. VERTICAL STEEL SEE SB-4 i° 1CF FLAT FORM WALL 44 x 2'-0" DOWELS @ 36" O.C. (5" MIN, EMBED) OR CUT OUT FOAM @ SLAB FOR 6" EVERY 24" & PLACE 44 x 2'-0" DOWELS @ 72" O.C. (5" MIN. EMBED) CONCRETE STRIP FOOT SEE SHEET SB-SD JOIST HANGER CUSP OR SIMPSON) w/ (6) 10d x 11/2" NAILS TO PLATE & NO NAILS TO JOIST 2 x 6 MIN, WOOD SILL PLATE T- mST DR 1NMR MR SYSTEM SPACING = 24" O.C. MAX ACTUAL SPACING BY OTHERS WALL SECTION 2 x 4 MIN. CONTINUOUS RIBBON BRACE I oa N W N X i 0 I 0 x w W x J J Q D, a ? SIMPSON A35 ANCHOR w/ 4 I. (4) 8d x 11/2" NAILS EACHILEG I I BOTH SIDES OF TRUSS I I 4 2 x 6 MIN. WOOD SILL PLATE TRUSS ELEER SYSTEM SPACING = 24" D.C. MAX ACTUAL SPACING BY OTHERS 2006 MASTER INSULATED CONCRETE I ADVANCED WALL SYSTEMS, IN, C. I FORM BELOW GRADE WALL DRAWINGS 16927231st AVENUE NW, BIG LAKE, MN 55309 WALL SECTION - SANDY-CLAY BACKFILL Phone: (763) 263-8512 Fax: (763) 253-5912 5201 East River Road Suite 309 Minneapolis. Minnesota 55421 Phone: 763.5712500 Fax: 763.571.1168 Bismarck Beb,Nt kxa Fargo.Wnn,xaa?SxWx Fell[ Web: eww.ullegcpm engineers p,pwe By, T,pyB?,pp, Checked By Trevor Axrer Approved By. Craig Csxell JOB SITE INFORMATION (to Ee 011ed out by the contractor) Snell Address: r1h Urrber: o tneH /?I1- /pl1 Januprv l.2fA6 v`I`„f( LI`•f( City: State- Zip code- 6 0 20 NOTES 1. PRIOR TO BACKFILLING, FOUNDATION WALLS MUST BE LATERALLY SUPPORTED BY FLOOR CONSTRUCTION AT TOP & SLAB AT BOTTOM OR BY ADEQUATE TEMPORARY BRACING, 2. SPECIAL REVIEW IS REQUIRED FOR WALLS HIGHER THAN 10'-0" T.O.S. TO T.O.W. 3, SEE SB-4 FOR PLACEMENT OF VERTICAL REBAR. 4, PROVIDE A MINIMUM OF TWO ANCHORS PER SECTION OF SILL PLATE, AS WELL AS AN ANCHOR WITHIN 12" OF EACH END. 5. DRAIN TILE, DAMPROOFING AND/OR WATERPROOFING, & INSULATION, AS WELL AS THEIR INSTALLATION, ARE TO BE IN ACCORDANCE WITH THE CODE. 6. SEE SB-1 FOR FURTHER NOTES AND CONSTRUCTION GUIDELINES. MATERIALS CONCRETE (28 DAYS): 3500 PSI AGGREGATE; FOOTING - 11/2" MAX WALLS - 3/4" MAX REINFORCING; ASTM A615 GRADE 60 BACK HEAVYCLAY - GROUP III FILL; EQUIVALENT FLUID PRESSURE (Yeq> = 60 PCF GROUPS BASED ON THE CODE 1/2"0 x 10" LONG ANCHOR BOLTS w/ (1). NUT & HEAVY DUTY WASHER (7" MIN. EMBED) @ 24" O.C. OR SIMPSON MAB15 OR APPROVED EQUAL @ 12" O.C. -\ SLOPE GRADE AWAY FROM FOUNDATION 1. I I a I, Y ) 1 w I I y 44 HORIZONTAL BARS @ 48" O.C. i y l 1. VERTICAL STEEL----//: SEE SB-4 ICF FLAT FORM WALL a I I; I 0 '+ `? I I I I ? = '14 x 2'-0" DOWELS i 0 @ 24" O.C. Li (S' MIN. EMBED) _ OR I I J Q CUT OUT FOAM @ SLAB FOR 6" SLAB ON EVERY 24" & i GRADE PLACE 44 x 2'-0' n I, DOWELS @ 72" O.C. -1' (5" MIN. EMBED) e ° a ° CONCRETE STRIP FOOTING- SEE SHEET SB-ID JOIST HANGER CUSP WALL SECTION OR SIMPSON> w/ (8) IOd x 11/2" NAILS TO PLATE & NO NAILS TO 2 x 4 MIN. CONTINUOUS JOIST RIBBON BRACE ?- SIMPSON A35 ANCHOR w/ '1 d !' (6) 8d x I VE" NAILS EACH !LEG 2 x 6 MIN, WOOD BOTH SIDES OF TRUSS SILL PLATE 2 x 6 MIN. WOOD SILL PLATE T-JMST OR Taro FLMR SYSTEM T tcc mR SYSTEM SPACING = 24" O.C. MAX SPACING = 24" O.C. MAX ACTUAL SPACING BY OTHERS ACTUAL SPACING BY OTHERS 2006 MASTER INSULATED CONCRETE ADVANCED WALL SYSTEMS, INC. FORM BELOW GRADE WALL DRAWINGS 169272315[ AVENUE NW, BIG LAKE, MN 55309 WALL SECTION - CLAY BACKFILL Phone: (763) 263-8512 Fax: (763) 263-59112 5201 East Rlyer Road Buite 308 JOB SITE INFORMATIONI gevieron Date D$ea"pbon Ito he eel out by Me pp rbeA-I) Minneapolis, Minnesota 55421 Phone: 763511.29)0 Fax: 763.5711169 Owmx:. 6hma"k-Deho61a1w FeW Mioeaped, Siena FaIS Wet:..ull.l,. Street A00reex b Drain By: Troy DoGmol Prole:ol NUmter: STl _/?/? "engineers CbeUCCd By: Trevor A,rer Date Jenua 1 J??L?•,j(JJ LL IV. AppreveE By' Craig Oewee Lily: S1ate:- Z'p COJa:_ Sheets: cr 11-=I a 1, NOTES 1. PRIOR TO BACKFILLING, FOUNDATION WALLS MUST BE LATERALLY SUPPORTED BY FLOOR CONSTRUCTION AT TOP & SLAB AT BOTTOM OR BY ADEQUATE TEMPORARY BRACING. 2. SPECIAL REVIEW IS REQUIRED FOR WALLS HIGHER THAN 10'-0" T.O.S- TO TAW. 3. SEE SB-4 FOR PLACEMENT OF VERTICAL REBAR. 4. PLASTIC BOLT HOLDERS MAY BE USED TO ALIGN ANCHOR BOLTS FOR LEDGER BOARD. ANCHOR BOLTS MAY BE PLACED IN PAIRS AT 2 X THE SPACING SHOWN. 5. DRAIN TILE, DAMPROOFING AND/OR WATERPROOFING, & INSULATION, AS WELL AS THEIR INSTALLATION, ARE TO BE IN ACCORDANCE WITH THE CODE. 6.LEDGER MAY BE UNTREATED AT FOAM CUT OUT PROVIDED ADEQUATE MEMBRANE 1S USED. 7, SEE SB-1 FOR FURTHER NOTES AND CONSTRUCTION GUIDELINES. MATERIALS CONCRETE (28 DAY): 3500 PSI AGGREGATE: FOOTING - 11/2" MAX WALLS - 3/4" MAX REINFORCING; ASTM A615 GRADE 60 BACK 100 % GRANULAR - GROUP 1 FILL; EQUIVALENT FLUID PRESSURE (Yeq) = 30 PCF GROUPS BASED ON CODE FIT i CHANGER CONNECTION 01/ TOP OF WALL= OFLJOISTGHT dI JOISTS BY OTHERS 1/2"0 x Be LONG ANCHOR BOLTS w/ HEAVY DUTY WASHERS @ 12" D.C. STAGGERED OR SIMPSON 1CFVL @ 48" O.C. w/ (6) SIMPSON D3 SCREWS 2 x 10 NO. 2 GRADE MIN. LEDGER BOARD 1- MST OR 2 x ELOOR SYSTEM SPACING = 24" Q.C. MAX ACTUAL SPACING BY OTHERS BOTTOM CHORD BEARING TRUSS CONNECTION SIMILAR III APPROPRIATE HANGER INCREASE LEDGER DEPTH & WIDTH AS REQUIRED FOR TRUSS CONNECTION ACTUAL SPACING BY OTHERS BOTTOM CHORD AND MIDDLE CHORD BEARING TRUSS CONNECTION SIMILAR BEAR ON TOP OF LEDGER(S) 12006 MASTER INSULATED CONCRETE ADVANCED WALL SYSTEMS, INC. I FORM BELOW GRADE WALL DRAWINGS 16927231st AVENUE NW, BIG LAKE, MN 55309 WALL SECTION - SAND BACKFILL Phone: (763) 263-8512 Fax: (763) 2635912 5201 Earn River Road SWIe300 Minnaapolle. vanneegla 55121 Phone: 763571.2500 Fax: 763.571.11M Bimlanl Deliat Laker-Fargo elnnewom-Slpu Falk Verdi: www 0wi, dorm engineers Drawn By: Troy DeGrool Checked By: Trevor Axner Approved By Crxlg Orwell JOB SITE INFOaMAT10N (lo be Iillecl out by the contacl0rl Owner' Sheer Addrad: CM: Pre,eollwmb& SB 3A Dale: Januan L 2 Shaer. 8 of !20 SEE ABOVE GRADE PACKAGE FOR WALL REDFO DO NOT PASS VERTICAL BARS FROM FOUNDATMN 1N TO HIGH WALL '14 x 2'-0" DOWELS @ 72" O.C. GROUT CUT (5" MIN. EMBED) OUT SOLID ' BEHIND ;LE: SLOPE GRADE @ BOLTS AWAY FROM FOUNDATION .11- x4 HORIZONTAL BARS @ 48' O.C. VERTICAL STEEL SEE SB-4 1CF FLAT - FORM WALL 04 x 2'-0" DOWELS @ 48" O.C. (5" MIN. EMBED) CUT OU?T RFOAM @ SLAB FOR 6" EVERY 24" & PLACE 44 x 2'-0" DOWELS @ 72" O.C. (5" MIN. EMBED> CONCRETE STRIP FOOTING SEE SHEET SB-ID IT a `SEE DETAILS ° FOR LEDGER pq J CONNECTION rn W3 W t` to C3 of d l Xo I I L ,I I r r' I t I r t a l ,I a k I SLAB ON " ' GRADE a (4) 346'0 x 6" LONG HARDENED NAILS OR A SIMPSON A35 ANCHOR w/ (6)j8d x 11/2" NAILS EACH LEG EITHER SIDE OF TRUSS TOP CHORD BEARING d I FLOOR TRUSSES BY OTHERS i of TOP OF WALL = TOP OF LEDGER -e ------ INSTALL ADDITIONAL 2 x LE, GER w/ (2) ROWS lOd NAILS @i 6 O.C. In STAGGERED OR EXTEND ANCHOR BOLTS AS REQUIRED TO SUPPORT %I d ADDITIONAL LEDGERS 1/2"O ANCHOR BOLTS @ 12j O.C. STAGGERED (6" MIN. EMBED) OR SIMPSON 1CFVL @ 48" O.Cl w/ (6) SIMPSON D3 SCREWS 2 x 10 NO. 2 GRADE MIN. TRUSS FLOOR SYSTEM LEDGER BOARD SPACIN-? D.C, MAX NOTES 1. PRIOR TO BACKFILLING, FOUNDATION WALLS MUST BE LATERALLY SUPPORTED BY FLOOR CONSTRUCTION AT TOP & SLAB AT BOTTOM OR BY ADEQUATE TEMPORARY BRACING. 2. SPECIAL REVIEW 1S REQUIRED FOR WALLS HIGHER THAN 10'-0" T.O.S. TO T.O,W. 3. SEE SB-4 FOR PLACEMENT OF VERTICAL REBAR. 4. PLASTIC BOLT HOLDERS MAY BE USED TO ALIGN ANCHOR BOLTS FOR LEDGER BOARD. ANCHOR BOLTS MAY BE PLACED IN PAIRS AT 2 X THE SPACING SHOWN. 5. DRAIN TILE, DAMPROOFING AND/OR WATERPROOFING, & INSULATION, AS WELL AS THEIR INSTALLATION, ARE TO BE IN ACCORDANCE WITH THE CODE, & LEDGER MAY BE UNTREATED AT FOAM CUT OUT PROVIDED ADEQUATE MEMBRANE IS USED. 7. SEE SB-1 FOR FURTHER NOTES AND CONSTRUCTION GUIDELINES. MATERIALS CONCRETE (28 DAY); 3500 PSI AGGREGATE; FOOTING - 11/e" MAX WALLS - 3/4" MAX REINFORCING; ASTM A615 GRADE 60 BACK GRANULAR & LIGHTCLAY - GROUP 11 FILL; EQUIVALENT FLUID PRESSURE (Yeq) = 45 PCF GROUPS BASED ON CODE °t - TOP OF WALL= I° OFLJOISTGHT LA ? I BY OTHERS Ill APPROPRIATE HANGER 2006 MASTER INSULATED CONCRETE FORM BELOW GRADE WALL DRAWINGS WALL SECTION - SANDY-CLAY BACKFILL SEE '14x2'-0" I CUT LEDGER Z , r 1=111 1- I O I-111- c "4 HORIZONTAL SEE DETAILS v ? BARS @ 48" O.C. FOR LEDGER CONNECTION rn a VERTICAL STEEL 3 SEE SB-4 a Ld 0 C4 ICF FLAT FORM WALL i, xa f v t14 x 2'-0" DOWELS _ X @ 36" O.C. o w (5" MIN, EMBED) I, oC3 ?R I 1 F CUT OUT FOAM @ SLAB FOR 6" i r LL3 EVERY 24" & w w? PLACE '14 x 2'-0" i. _ DOWELS @ 72" D.C. ° J w (5' MIN. EMBED) I I SLAB ON ¢ w CONCRETE STRIP FOOTING i i GRADE 3 w SEE SHEET SB-ID y I I I ; e e e° WALL SECTION (5) 3/16'0 x 6" LONG HARDENEDI NAILS OR A SIMPSON A35 ANCHOR w/ (6) 8d x 11/2" NAILS EACH LEG BOTH SIDES OF TRUSS TOP CHORD BEARING FLOOR TRUSSES BY OTHERS TOP OF WALL = TOP OF LEDGER ° INSTALL ADDITIONAL 2 x LE,?GER w/ (2) ROWS 10d NAILS @ 6 STAGGERED OR EXTEND ANCHOR BOLTS AS REQUIRED TO SUPPORT ADDITIONAL LEDGERS 1/2"0 ANCHOR BOLTS @ 12" O.C. STAGGERED (6" MIN. EMBED) OR i SIMPSON 1CFVL @ 48" O.C, w/ (6) SIMPSON D3 SCREWS 2 x 10 NO. 2 GRADE MIN, TRUSS FLOOR SYSTEM LEDGER BOARD SPACING = 2 O.C. MAX ACTUAL SPACING BY OTHERS F BOTTOM CHORD AND MIDDLE CHORD BEARING TRUSS CONNECTION SIMILAR BEAR ON TOP OF LEDGER(S) ADVANCED WALL SYSTEMS, 16927231st AVENUE NW, BIG LAKE, MN Phone: (763) 2638512 Fax: (763) 263-5 5201 East Rivet Redd Suite 308 Minneapoes. Mlnneeate 55421 Phone: 763 571.2500 Fax: 7W.571.1 168 Blsmeek.Desel Lakes-FaW Milmeapo" S*W falls Web: www ul[egmm engineers Drawn By, Troy OeGroof Checked By Trevor Axner Appovedl By: Cray Oswee JOB SITE INFORIAATION Ito be filled out by the Cohnadbur) Street Address' cut: I DOWELS @ 72" O.C. GROUT (5" MIN. EMBED) OUT SO EBOLT SLOPE GRADE1 S AWAY FROM FOUNDATION ? Pmlem SM1eets: NUmbm z Bds0l1120 3es Dete: Jan"nrv 1. ztidfi ZipCotle' I SB-3B i/2"0 x 8" LONG ANCHOR BOLTS w/ HEAVY DUTY WASHERS @ 12" O.C. STAGGERED OR SIMPSON 1CFVL @ 48" D.C. w/ C6> SIMPSON D3 SCREWS 2 x 10 NO. 2 GRADE MIN, LEDGER BOARD i-.rtwSi n12 2 x?J,CY1R SYSTEM SPACING = 24 O,C. MAX ACTUAL SPACING BY OTHERS BOTTOM CHORD BEARING TRUSS CONNECTION SIMILAR INCREASE LEDGER DEPTH & WIDTH AS REQUIRED FOR TRUSS CONNECTION NOTE SEE ABOVE GRADE PACKAGE FOR WALL REINFORCING DO NOT PASS VERTICAL BARS FROM 1. PRIOR TO BACKFiLLING, FOUNDATION WALLS FOUNDATION INTO NIGH WALL MUST BE LATERALLY SUPPORTED BY FLOOR 44 x 2'-0" CONSTRUCTION AT TOP & SLAB AT BOTTOM OR DOWELS @ 72" O.C. i I GROUT CUT BY ADEQUATE TEMPORARY BRACING. (5 MIN. EMBED) OUT SOLID r BEHINDiLEDGER 2. SPECIAL REVIEW 1S REQUIRED FOR WALLS @ BOLTS HIGHER THAN 10'-0" T.O.S. TO TAW. SLOPE GRADE 3. SEE SB-4 FOR PLACEMENT OF VERTICAL REBAR. AWAY FROM°' FOUNDATION 4. PLASTIC BOLT HOLDERS MAY BE USED TO z ALIGN ANCHOR BOLTS FOR LEDGER BOARD. I ANCHOR BOLTS MAY BE PLACED IN PAIRS I„III l r AT 2 X THE SPACING SHOWN. 44 HORIZONTAL . o SEE DETAILS d 53 5. DRAIN TILE, DAMPROOFING AND/OR BARS @ 48" O.C. ° FOR LEDGER pq WATERPROOFING, & INSULATION, AS WELL CONNECTION 0 AS THEIR INSTALLATION, ARE TO BE VERTICAL STEEL L33 IN ACCORDANCE WITH THE CODE. SEE SB-4 o 6r LEDGER MAY BE UNTREATED AT FOAM CUT N 0 1CF FLAT 1 - OUT PROVIDED ADEQUATE MEMBRANE IS USED. FORM WALL-` AI X 0- 7. SEE SB-1 FOR FURTHER NOTES AND CONSTRUCTION GUIDELINES. 44 x 2'-0' DOWELS a MATERIALS e 24" O.C. CONCRETE (28 DAY): 3500 PSI (5" MIN. EMBED) AGGREGATE: FOOTING - 11/2" MAX ° OR WALLS - 3/4 r' MAX 1 1 '? CUT OUT FOAM r ? REINFORCING: ASTM A615 GRADE 60 @ SLAB FOR G" BACK HEAVYCLAY - GROUP III EVERY 24" & I I .-r W PLACE 44 x 2'-0" 1 r FILL: EQUIVALENT FLUID PRESSURE i, DOWELS @ 72' O.C. (Yeq) = 60 PCF (5" MIN. EMBED) i J GROUPS BASED ON CODE SLAB ON ¢ w e / HANGER CONNECTION CONCRETE STRIP FOOTING i. GRADE 3 J w BY OTHERS SEE SHEET SB-1D W p 1? I fn I- -? TOP OF WALL= ° HALF HEIGHT f , ,1 1 OF JOIST a WALL SECTION I ° I! (6) 3/ib'o x 6" LONG HARDENED: NAILS OR /I FLOOR JOISTS BY OT HERS A SIMPSON A35 ANCHOR w/ (6) ed x 11/2" 1/2"0 x 8" LONG ANCHOR NAILS EACH LEG BOTH SIDES OF TRUSS BOLTS w/ HEAVY DUTY n TOP CHORD BEARING - WASHERS @ 12" O.Cr FLOOR TRUSSES BY OTHERS STAGGERED ?R SIMPSON p1'' STOP OF WALL TOP OF LEDGER ICFVL @ 48" O.Cr I"-- -- ----.-? w/ (6) SIMPSON o INSTALL gDDITIONAL 2 x LE{IGER ' D3 SCREWS w/ (2) ROWS 10d NAILS @, 6 O.C. 2 x10 NO. 2 GRADE M1Nr? ai STAGGERED OR EXTEND ANCHOR BOLTS AS REQUIRED TO SUPPORT LEDGER BOARD ;I ADDITIONAL LEDGERS a 1 T- ST oR=2 x rQC. rotMAX sysrrM SPACING 1 1/2"O ANCHOR BOLTS @ 126' O.C. 1 " ACTUAL SPACING BY OTHERS STAGGERED (6 MIN. EMBED) OR / SIMPSON ICFVL @ 48" O.CI w/ (6) BOTTOM CHORD BEARING SIMPSON D3 SCREWS 2 x10 N0. TRUSS CONNECTION SIMILAR 2 GRADE MIN. N? E? LEDGER BOARD SPACi 24 OCi MAX w/ APPROPRIATE HANGER INCREASE LEDGER DEPTH & ACTUAL SPACING BY OTHERS WIDTH AS REQUIRED FOR BOTTOM.GHORD AND MIDDLE CHARD BEARING TRUSS TRUSS CONNECTION CONNECTION SIMILAR BEAR ON TOP OF LEDGER(S) I 12006 MASTER INSULATED CONCRETE I ADVANCED WALL SYSTEMS, INC. I FORM BELOW GRADE WALL DRAWINGS 16927 231st AVENUE NW, BIG LAKE, MN 55309 WALL SECTION - CLAY BACKFILL Phone: (763) 263-8512 Fax: (763) 263-591'2 5201 Ea d River Road Suite 308 Minnealaelis.Minneseld 55421 Ptlnne: 763,571,2500 F= 763.5711168 Bumxck-Wroil Lakea-FA,o?MmnegcfiS-Sbus FdI Web: v,vi, telg.com engineers omwn By: Trey DeGrool Ctyokad By: Trevor A.r,er Approved By: Crag Oawell JOB SITE INFORMATION (I. be idled out by the Contract.) Omer: Street Adidreas: CIIy: Slale:_ zip Cpde:? Project NUmAer: MIM Darn Janunre 1. 2p SB-3C Sheers: 100i20 lo 1,. r?. I? ti7 I?, 6't & GREATER ICF FLAT FORMS BASEMENT WALL VERTICAL REINFORCING REQUIREMENTS Clear Height of Backfill Height Above 6" FLAT FORM 8" FLAT FORM 10" FLAT FO_R.M_ --- ___ . IC F Wall Top of Slab 30 GROUPI 45 GROUP II 60 GROUP III 30 G R 0 U P I 45 GROUP II 60 GROUP III 30 G R 0 U P I 45 GROUP II 60 GROUP III 5'-0" NONE NONE #5@36 NONE NONE NONE NONE NONE NONE NONE #5@36 #5@36 NONE NONE NONE NONE NONE 7'0" #5@36 #5@36 #5@24 NONE NONE #5@36 NONE NONE 8'-0" #5@36 #5@24 #4@12 NONE #5@36 #5@24 NONE NONE 5'-0° NONE NONE #5@36 NONE NONE NONE H NONE NONE 6'-0" NONE #5@36 #5@36 NONE NONE NONE ON NONE NONE #5@36 #5@24 #5@24 NONE NONE #5@24 NONE NONE @36 #5@24 12 NONE #524 #5@24 NONE #5@24 9'-0° #5@ 24 #4@ 12 #5@ 12 #5@ 36 #5@ 24 #5@ 24 #5@ 24 #5@24 51-0" NONE NONE #5@36 NONE NONE NONE NONE NONE NONE 6'-0" NONE #5@36 #5@24 NONE NONE NONE NONE NONE NONE 10'-0" 7'-0" #5@36 #5@24. #5@24 NONE #5@36 #5@24 NONE NONE NONE #5@36 #4@12 #5@12 NONE #5@24 #5@24 NONE NONE _ #5@24 9'-0" #5@ 24 #4@ 12 #5@ 12 #5@ 36 #5@ 24 #4@ 12 N ON E #5 @2 4 #5@ 24 10'-0" #4@ 12 #5@ 12 S.E.R. #5@ 24 #4@ 12 S.E.R. NONE #5@ 24 S.E.R. NOTES: 1. The full outside dimension of the 6", 8", and 10" flat form walls are approximately t1", 13°, and 15" respectively. 2. Concrete thicknesses shown are actual dimensions. 3. Wall height is measured from the top of stab (T.O.S ) to the top of wall (T.O.W.). See the details on sheets SB-2 and SB-3 for the top of wall location. 4. All steel reinforcing is to be Grade 60 Taber. 5. Steel rebar sizes may be substituted using the following ratios: #4@12 = #6@24, #4@24 = #5@36, and #5@24 = #6@36, Alternative substitutions are to be made using equivalent area of steel. Substituted sizes are not to exceed 48" on center. 6. Horizontal reinforcing is to be a in inim um of #4 @ 48" O.C. for all wall conditions. 7, Use concrete with a minimum 28 days compressive strength of 3500 psi. 8. The basem ant floor slab is to be in place and the first floor framing installed prior to the baCkfilling of the walls unless adequate temporary bracing is used. 9. The vertical rather is to be placed 1'/z" from the inside face of the concrete portion of the ICF wall. 10. See note 1 on sheet SS - 1 for the limitations of the structure associated with these tables. 11. Special inspection is NOT required for standard wall construction builtin accordance with this table and this drawing package. 12. Maximum concentrated vertical load to be applied to the wall, such a$ from girder trusses or beams, is 20,000 pounds for the six-inch farm and 40,000 pounds for the eight-inch or greater form. This load capacity assumes that all concentrated loads bear within the center 4' of the wall. This load is the actual load applied to the wall, note factored load. 13. S.E.R.: Special engineering review is required for these conditions. 2006 MASTER INSULATED CONCRETE I ADVANCED WALL SYSTEMS, INC. FORM BELOW GRADE WALL DRAWINGS 16927 231st AVENUE NW, BIG LAKE, MN 55309 J FOUNDATION WALL REINFORCEMENT TABLE Phone: (763) 263-8512 Fax: (763) 263-5912 5281 East Riser Road Suite 308 Minneapohe,Mixtearra 55021 Phone: 763.571.2500 Fax: 763571 1168 Norack Deaoit"aw-Fargo?MnnsaWis?Slaux Falb Web: www.ultelg.eoT JOB SITE INFORMATION gevlyon Ito be filled out by the contra dop Owner Street Address' engineers Drawn By. Troy DeGroot Checked By'. T'. A.. Approved By: Craig Oswell aiaptN mda, . Dale: Ja„uar 1.20M' D ` SB-4A Sheets: 110M XILLIX 6" & 8" FLAT FORMS BASEMENT WALL VERTICAL RFTNFnRr1Nr RF011TR17MF'K1TC Clear Backfili Height Height 6" FLAT 8"FLAT of Above FORM FORM ICF W all Top of Slab 30 G R O U P I 45 G R O U P I I 60 G R O U P I I I 30 G R O U P I 45 G R O U P 1 1 60 G R O U P I I I n 5'-D' ' " N O N E N O N E # 5@ 36 N O N E - N O N E N 0 N E 8 -o 6 -0 " ' N 0 N E #S@ 36 #5@ 36 WO N E N 0 N E N O N E -0 7 " 1 #5@36 #5@24 #5@24 NONE #5@36 #5@36 8 -0 ' " #5@36 #5 24 #4@12 NONE #5@'36 #5@24 5 -0 NONE NONE #5@36 NONE NONE NONE " ' 6'-0" #5@48 #5@36 #5@24 NONE NONE #5@36 -0 9 ' " #5@ 36 #5@ 24 #4@ 12 N 0 NE #5@ 36 #5@ 24 8 -0 ' " #5@ 24 #4@ 12 #5@ 12 N 0 NE #5@ 24 #5@ 24 9 -0 #5@ 24 #5@ 12 #5@ 12 #5@ 36 #5@ 24 #4@ 12 N O N E 95@ 48 45@ 36 N 0 N E N O N E N O N E ' " 6'-0" ' ' #5@48 #5@36 #5@24 NONE NONE #5@36 10 -0 7 -0 ' " #5@ 36 #5@ 24 #4@ 12 -NO N E #5@ 36 #5@ 24 8 -0 ' #5@ 24 #4@ 12 95@ 12 5 @ 38 #5@ 24 #5@ 24 9 #5@ 24 #5@ 12 #6@ 12 @ L!5 36 #5@ 24 #4@ 12 100 #4@ 12 #5@ 12 S.E.R 5@ 24 #4@ 12 S.E.R. NOTES: 1. The full outside dimension of the 6" Xillix flat form wall is 9%". The full outside dim erasion of the 8" Xillix flat form wall is l1'/." 2. Concrete thicknesses shown are nom inal dimensions. The concrete thickness for the 6" Xillix flat form wall is 5%"'. The concrete thickness for the 8" Xillix flat form wall is 7y1". 3. Wall height is measured from the top of slab (T.O.S )to the top of wall (T.O.W .). See the details on sheets SB-2 and 3 3-3 for the top of wal location. , 4. All steel reinforcing is to be Grade 60 rebar. 5. Steel rebar sizes may be substituted using the following ratios: 44@ 12 = #6@ 24, #4@ 24 = #5@ 36, and #5@ 24 = #6@ 35. Alternative substitutions are to be in ade using equivalent area of steel, Substituted sizes are not to exceed 48' an center, 6. H orizontal reinforcing is to be a mi nim um of #4@4B" O. C. for all wall conditions. 7. U se concrete with a m inim um 28 days compressive strength of 3500 psi: B. The basem ant floor slab is to be in place and the first floor fram ing installed prior to the backfilling of the walls unless adequate tem porary bracing is used. 9. The vertical rebar Is to be placed 1X' from the inside face of the concrete portion of the ICF wall. 10. See note l on sheet 56 - 1 for the limitations of the structure associated with these tables. 11. Special inspection Is NOT required for standard wall construction built in accordance with this table and this drawing package. 12. Maximum concentrated vertical load to be applied to the wall, such as from girder trusses or beams, is 20,000 pounds for the six-inch form and 40,000 pounds for the eight-inch form. This load capacity assumes that all concentrated toads bear within the center 4" of the wall. This load is the actual load applied to the wall, not a factored load. 13. S.E.R.; Special engineering review is required for these conditions. 2006 MASTER INSULATED CONCRETE ADVANCED WALL SYSTEMS, INC. FORM BELOW GRADE WALL DRAWINGS 16927231st AVENUE NW, BIG LAKE, MN 55309 FOUNDATION WALL REINFORCEMENT TABLE Phone: (763) 263-8512 Fax: (763) 263-5912 5201 East Rivcv Boost Suite 30a Minneapolis. Minnesota 55421 Pbonet 763.571.2500 Fax: 763.571.1188 Element ]i Lakes Flp Annuli Sioux Falk Web: www.ultsi0.coln engineers prawn ey: Troy Deomm Checked By TreVar Ames Approved By: Cratgl]swa0 JOB SITE INFORMATION (to be filled Out by the contracmd Stan, -' P Done . e [Number Jap er t 2006 sot I SB-4B City: State:. Zp OWe: Sheers: 12 of 20 NnTEs 1. PRIOR TO BACKFILLING, FOUNDATION WALLS MUST BE LATERALLY SUPPORTED BY FLOOR CONSTRUCTION AT TOP AND SLAB AT BOTTOM OR BY ADEQUATE TEMPORARY BRACING. 2. USE A MINIMUM OF (2) ANCHORS FOR EACH PORTION OF SILL PLATE, PLACE AN ANCHOR WITHIN 12" OF EACH END, 3. DRAIN TILE, DAMPROOFING AND/OR WATERPROOFING, & INSULATION, AS WELL AS THEIR INSTALLATION, ARE TO BE IN ACCORDANCE WITH THE CODE. 4. DOWELS ARE TO BE WET SET OR DRILLED IN AND EPOXY GROUTED TO FOOTING. 5. SEE S3-1 FOR FURTHER NOTES & CONSTRUCTION GUIDELINES. 1/2"m x 10" LONG ANCHOR BOLTS w/ (1) NUT & HEAVY DUTY WASHER (7'r MIN, EMBED) OR SIMPSON HAB15 ANCHOR OR APPROVED EQUAL @ 72" O.C. SLOPE GRADE AWAY FROM FOUNDATION (1) 44 HORI BAR @ TOP 1CF FLAT - FORM WALL 44 x 2'-0" DOWELS @ 48" O.C. (SAND SOILS) 36" O.C. (SANDY-CLAY 24" O.C. (CLAY SOILS) (5" MIN, EMBED) 20" WIDE x 8" THICK STRIP FOOTING (MIN.) PROVIDE CODE REQUIRED FROST PROTECTION TO BOTTOM OF FOOTING MATERIALS CONCRETE WO: 3500 PSI @ 28 DAYS AGGREGATE: FOOTING - 11/2" MAX WALLS - 3/4" MAX REINFORCING: ASTM A615 GRADE 60 GROUPS BASED ON CODE 2 x 4 MIN, WOOD FRAME WALL BY OTHERS 2 x 4 MIN. WOOD SILL PLATE 1 ? 1 r i I °r a I? I' ? I I ? i t, t° t e? 1 ? I r o eA WALL SECTION 2006 MASTER INSULATED CONCRETE ADVANCED WALL SYSTEMS, INC. FORM BELOW GRADE WALL DRAWINGS 16927 231st AVENUE NW, BIG LAKE, MN 55309 LOOKOUT WALL SECTION Phone: (763) 263-8512 Fax: (763) 263-5912 5201 East Roar Roadl Sped 306 JOB SITE INFORMATION Mmson Dale 0laiption De be NNE out by me mmrador) Ml nneapotiS, Minnesota YK21 Phone763.571.2500 Fax: 769.571,1166 Owner: axrhs k Detmil Laoax-Fargo-Minneapolh-Siouw Falk Webwww.utleipmm E SVeet Address: engineers ?l PmlecrNUrMe, o t399 DrarnBy: Troy De rA at. 2006 . 'lama SB-5A AlMrovetl BY: Crdip OSweII City: .State: Zip Code: 'A n She ers NOTES 1. CARE IS TO BE TAKEN DURING BACKFILLING TO MAINTAIN A PLUMB WALL ALIGNMENT. BRACE AS REQUIRED, 2. USE A MINIMUM OF (2) ANCHORS FOR EACH PORTION OF SILL PLATE. PLACE AN ANCHOR WITHIN 12" OF EACH END. 3. DRAIN TILE, DAMPROOFING AND/OR WATERPROOFING, & FRAMEWALL INSULATION, AS WELL AS THEIR INSTALLATION, ARE TO BE IN ACCORDANCE WITH THE CODE. 4. DOWELS OR OTHER FOOTING TO WALL CONNECTIONS ARE NOT REQUIRED IF BACKFILL 1S PLACED EQUALLY ON BOTH SIDES IN ALTERNATING LIFTS NOT EXCEEDING 24" IN HEIGHT, 5. SILL PLATE & FRAMEWALL NAILING ARE TO BE IN ACCORDANCE WITH THE CODE. 6. SEE SB-1 FOR FURTHER NOTES & CONSTRUCTION GUIDELINES. 1/2 "O x 10" LONG ANCHOR BOLTS w/ (1) NUT & HEAVY DUTY WASHER (7" MIN, EMBED) OR SIMPSON MAB15 ANCHOR OR APPROVED EQUAL @ 72" O.C. SLOPE GRADE AWAY FROM FOUNDATION MATERIALS CONCRETE (F'c): 3500 PSI 1 28 DAYS AGGREGATE: FOOTING - 11/2 MAX WALLS - 3/4" MAX REINFORCING: ASTM A615 GRADE 60 2x4 MIN, WOOD FRAME WALL BY OTHERS 2 x 4 MIN. WOOD SILL PLATE SLAB ON GRADE e ° ° e ° •.3,-Drl li ?-t ? 1-I I MAX. -l (1) 44 HORIZONTAL i ° BAR @ TOP OF WALL ICF FLAT i ` FORM WALL l° I e °4 x 2'-0" i CONCRETE STRIP FOOTING DOWELS @ 72 O.C. SEE SHEET SB-ID (5" MIN. EMBED) ' PROVIDE CODE REQUIRED FROST PROTECTION TO ,1 r BOTTOM OF FOOTING e ° a WALL SECTION 2006 MASTER INSULATED CONCRETE ADVANCED WALL SYSTEMS, INC. FORM BELOW GRADE WALL DRAWINGS 16927 231st AVENUE NW, BIG LAKE, MN 55309 FROST WALL SECTION Phone: (763) 263-8512 Fax: (763) 263.5912 Rol East River Road Sum 3011 JOB SITE INFORMATION Reyislon Date Das iption hinneapdi5. Minnesota 55a21 110 be filled0u1 ty Ne Wnlra lar) Phone: 761.5712500 Faa: 763.571.11611 Oenec Bieoarca DeVshiolas Fargo-Wnneapo6 Sider Falls Web: www.ulleig.cgm Street Address' engineers Drawn By: Tro, D¢G.1 Projest NU,rbec 5 9 Chewed By: Trevor A.ner Approved By: Craig Devel clry: slate -zip coal Dale: JanOerv 1 _2obe Sllee6: last YO SB-56 Nrl T ES: 1. PROVIDE BEAM DEPTH TO GIVE CODE REQUIRED FROST PROTECTION BELOW FINAL GRADE OR PROVIDE 4" THICK x THE WIDTH OF THE WALL POLYSTYRENE INSULATION UNDER THE BEAM- MATERIALS CONCRETE (F'c); 3500 PSI 2 28 DAYS AGGREGATE: FOOTING - it/e" MAX WALLS - 3/4" MAX REINFORCING; ASTM A615 GRADE 60 SEE OTHER DETAILS FOR WALL REINFORCEMENT GRADE BEAM CAPACITY= GRADE BEAM CAN SUPPORT A UNIFORM SERVICE LOAD OF 6000 PLF OR A POINT LOAD OF 12000 POUNDS AT ANY LOCATION ALONG THE GRADE BEAM. 6" WIDE GRADE BEAM MIN. EXTEND BARS 24" INTO WALL EACH END CONCRETE FOOTING COMPACTED FILL OR VIRGIN MATERIAL SEE NOTE 1 MAX. SPAN 6'-0" z (2) 45 HORIZONTAL BARS TOP & w BOTTOM OF WALL M CONCRETE FOOTING COMPACTED FILL OR VIRGIN MATERIAL COMPACTED FILL OR STABLE BANK GRADE BEAM STEP FOOTING 2006 MASTER INSULATED CONCRETE ADVANCED WALL SYSTEMS, INC. FORM BELOW GRADE WALL DRAWINGS 16927231st AVENUE NW, BIG LAKE, MN 55309 JUMP-FOOTING DETAIL Phone: (763) 263.8512 Fax: (763) 263-5912 5201 East River Road Suite 308 Mimmusiati6. Minne50ta 5$21 Phone: ]63.91.2500 Fax: 763 571,1160 B6neaxl-obese takes Fatio- klltvwapols, Said Falls web: wwwudeg... engineers Drawn By: Troy DeGroot Cheoked By: Trevor Mne, Approval By: Crag OxweO JOB SITE INFORMATION (lo be lilkd out by the conVdClorl Owner. City: State:_ Zip Code:_ Dale P,olaot Notes, 20513% SB-6 Data: Januerv 1 M06 Breaux: 15 d'zz (16) 10d NAILS INTO BLOCKING 10d NAILS E 6" D.C. MANUFACTURED OR MIN. 2 x 10 RIM JOIST JOIST HANGER CUSP OR SIMPSON) w/ (8) lOd x 11/8" NAILS TO PLATE & NO NAILS TO JOIST 2 x 6 MIN. WOOD SILL PLATE SEE SHEET SB-2 FOR ANCHORS WOOD FLOOR JOISTS BY OTHERS MANUFACTURED ORS MIN, 2 x 10 BLOCKING 8 48" O.C. (SAND) 8 36" O.C. (SANDY-CLAY) OR 24" D.C. (CLAY) OR IN FIRST (2) JOIST SPACES w/ (4) 10d TOE NAILS EACH END TO JOIST BLOCKING SPACING MAY BE INCREASED TO 6'-0" O.C. WHEN GRADE DROPS TO LESS THAN 6'-0" ABOVE BASEMENT SLAB- ON-GRADE ALL DETAILS (16) 10d NAILS INTO BLOCKING WOOD FLOOR TRUSSES -? BY MANUFACTURER 2 x 4 BLOCKING T 8 B- OF TRUSSES IN FIRST (2) TRUSS SPACES 2 48" O.C. (SAND) 8 36" O.C. (SANDY-CLAY) OR 2 24" O.C. (CLAY) OR w/ (4) 10d TOE NAILS EACH END 3/4" PLYWOOD ONE SIDE) OF BLOCKING IN FIRST (2) TRUSS SPACES w/ (8) Bid NAILS TOP & BOTTOM SEE SHEET SB-2 FOR WALL REINFORCEMENT REBAR NOT SHOWN SLOPE GRADE IOd NAILS 2 6" O.C. t -' AWAY FROM FOUNDATION °. ?; ?illll??ll -I 1 I- ENGINEERED RIM TRUSS BY OTHERS INSULATE PER CODE ATTACH BOTTOM CHORD OF TRUSS TO SILL w/ MIN (6)' 10d NAILS EACH SIDE OF BLOCKING 2 x 6 MIN. WOOD SILL PLATE 4 SEE SHEET SB-2 FOR ANCHORS SEE SHEET SB-2 FOR WALL REINFORCEMENT i REBAR NOT SHOWN rSLOPE GRADE ?? I AWAY FROM r a a I FOUNDATION ? III- 11.= tit WALL SECTION PARALLEL TO FRAMING FLOOR JOISTS SHOWN AT TOP & TRUSSES SHOWN AT BOTTOM 12006 MASTER INSULATED CONCRETE I ADVANCED WALL SYSTEMS, INC. I FORM BELOW GRADE WALL DRAWINGS 16927 231st AVENUE NW, BIG LAKE, MN 55309 NON-BEARING WALL BLOCKING SECTION Phone: (763) 263-8512 Fax: (763) 263-591 5201 East River Road Sere 308 Minneapolis, Minnesota 55x21 Pfwne: 7635712500 Fax'. 763.571.1168 Bizmarck.0eed1 LakM Fargo-Mimeapols Sioux Ras web: www.utteg com engineers Drown By: Troy oecmol Checked By: Tre Axnatr Approved By: Crag OZ ell JOB SITE INFORMATION (lo be filled out 0, ;he conlracWp Coiner Street kddreds: city: Shte:_ Zip Cade:_ 205 1399 Data: Nu= drr x12 66 Date: Jaou. SPA Bheelz: 16 "f f F. 10d NAILS 8 6" D.C. NAILS (16) 10d INTO BL OCKDJG I ° WOOD FLOOR JOISTS BY OTF MANUFACTURED OR MIN. 2 x 10 BLOCKING E 48" D.C. (SAND) 8 36" O.C. (SANDY-CLAY) OR B 24" O.C. (CLAY) OR IN FIRST (2) JOIST SPACES w/ (4) 10d TOE NAILS EACH END I NAILS INTO BLOCKING WOOD FLOOR TRUSSES BY MANUFACTURER 2 x 4 BLOCKING T & B'/ OF TRUSSES IN FIRST (2) TRUSS SPACES 2 48" O.C. (SAND) B 36" O.C. (SANDY-CLAY) OR 8 24" O.C. (CLAY) OR w/ (4) 10d TOE NAILS EACH END 3/4" PLYWOOD ONE SIDE OF BLOCKING IN FIRST (2) TRUSS SPACES w/ (8) 8d NAILS TOP & BOTTOM MANUFACTURED OR MIN. 2 x 10 NO. 2 GRADE LEDGER BOARD CUT OUT FORM & GROUT SOLID BEHIND LEDGER 8 BOLTS r I SLOPE GRADE AWAY 7'. I ' FROM FOUNDATION ° ANCHOR BOLTS OR ° ANCHOR SEE SE-3 FOR MORE INFORMATION ,I r ?', SEE SHEET SB-3 FOR WALL REINFORCEMENT REBAR NOT SHOWN I ¢ BLOCKING SPACING,MAY BE INCREASED TO 6'-0" O.C. WHEN GRADE DROPS TO LESS THAN 6'-6" ?I ABOVE BASEMENT SLAB- / ON-GRADE ALL DETAILS 10d NAILS 2 6' D.C. GRADE I, FROMEFOUNDATI NAY I I; J°°° I ?I ? ?I I I„I? I I 2 x 4 LEDGER TOP & B13TT13N w/ 1/2,0 x B" LONG ANCHOR BOLTS R 24" O.C. CUT OUT FORM & GROUT I SOLID BEHIND LEDGER . °' I B BOLTS I' SEE SHEET SB-3 FOR WALL REINFORCEMENT REBAR NOT SHOWN WALL SECTION PARALLEL TO FRAMING FLOOR JOISTS SHOWN AT TOP & TRUSSES SHOWN AT BOTTOM 12006 MASTER INSULATED CONCRETE I ADVANCED WALL SYSTEMS, INC. I FORM BELOW GRADE WALL DRAWINGS 16927231st AVENUE NW, BIG LAKE, MN 55309 NON-BEARING WALL BLOCKING SECTION Phone: (763) 263-8512 Fax: Q63) 263-5912 52D1 East River HOW Suite 308 Mlm¢aFees Minnesota 55¢21 763.571.2500 Fax: 763.571.1169 Mae: Bismerdo Devo2 taker -Fargo - MinrnaNuS SUm FBAs Web: w u9elg.com ° engineers Drawn By: Troy DeBi xhQ1} .?:,. CheclW18y: Tt¢vor Axner ApprovWl By Cray Oswell JOB SITE INFORNATION Flowe. Data Oescnpepn IM be lilMU Wt OF me COntrdlt0l) Dwner SI(WR Add esa: Proles =i. M 1SB-7B Date: 1.2Ciry: Slele:_Zip COtle:? Shaete: OmSep NOTES 1. HORIZONTAL REINFORCING IS TO BE CENTERED IN WALL & EXTEND A MINIMUM OF 24" PAST THE OPENING AT EACH END. 2r LINTELS THAT SPAN 4 FEET OR LESS & SUPPORT 3000 PLF OR LESS, OR LINTELS THAT SPAN 6 FEET OR LESS & SUPPORT 1200 PLF OR LESS, DO NOT REQUIRE SHEAR REINFORCING. 3. ALL WALL OPENINGS ARE TO HAVE A MIN, OF 24" OF CONCRETE WALL BETWEEN THEM, ADJACENT 6-FOOT WIDE MAX, OPENINGS MAY HAVE A MINIMUM OF 12" OF CONCRETE WALL BETWEEN THEM. 4. PLACE AN ADDITIONAL (1> "5 BAR VERTICAL OR A TOTAL OF (1) "16 BAR VERTICAL FULL HEIGHT EACH SIDE OF ALL OPENINGS. 5, SEE SB-1 FOR FURTHER NOTES AND CONSTRUCTION GUIDELINES. 6. SPECIAL REVIEW IS REQUIRED FOR LINTELS BEYOND THESE LIMITS. 7, LOADS SHOWN ARE IN ADDITION TO LINTEL SELFWEIGHT. t13 SHEAR REINF @ I2rl D.C. MATERIALS CONCRETE; 3500 PSI @.28 DAYS AGGREGATE; WALLS - 3/4" MAX HORIZONTAL REINFORCEMENT; ASTM A615 GRADE 60 SHEAR REINFORCEMENT; ASTM A615 GRADE 60 LOADS LIVE LOAD; 42 PSF ROOF MAX. LIVE LOAD; 40 PSF FLOOR DEAD LOAD;15 PSF ROOF DEAD LOAD;12 PSF FLOOR WIND LOAD; 90 MPH EXPOSURE B I Z f v I? 'N-1 HORIZONTAL REBAR J 1 1 " , ° 1 TOP & BOTTOM 51/2" PER TABLE MIN, TYPICAL CONCRETE LINTEL HORIZONTAL BARS LINTEL SPAN IN FEET T& B 4 5 6 7 8 9 10 12 14 16 18 0) "5 5800 3700 2500 1800 1400 1100 B00 500 400 200 1200 (2) #4 6000 4700 3200 2300 1800 1400 1100 700 500 300 200 (1) ^6 6000 5700 3500 2600 1900 1500 1200 800 600 400 200 U) #7 OR (2) 45 6000 6000 4100 3500 2600 2100 1600 1000 600 400 1200 NT FOR 6" AND THICKER LINTELS 2006 MASTER INSULATED CONCRETE FORM ABOVE GRADE WALL DRAWINGS LINTEL SECTION AND REINFORCEMENT TABLE ADVANCED WALL SYSTEMS, INC. 16927231st AVENUE NW, BIG LAKE, MN 55309 Phone: (763) 263-8512 Fax: (763) 263-59112 5201 Eaai BBmamd Suite 306 JOB SITE INFORMATION (lo be filled oW b the wnQM l Q Rci'la. Dare Deaedp. XlinneaWi t. wannes. 55121 - Pli 763 57 y . o 1 . 1.250D Fax: 763.91.1166 owna, Samara O."d I.A.-Fargo. Minneei &i,,, Falha Web: www.Wtelg Cnm Steel kfdu S' B ?dengineers OrawuBy:TpyDeGroOt Pmjee,NunUee 1 CM1 Y. cl By: Trevor Amer Approved By: Craq DSwell CiW SIaa:_Zlp COde:_ 3 Dale: January 1.20M Sh.i 1PMJll 1HA NOTES 1. HORIZONTAL REINFORCING IS TO BE CENTERED IN WALL & EXTEND A MINIMUM OF 24" PAST THE OPENING AT EACH END. 2.LINTELS THAT SPAN 8 FEET OR LESS & SUPPORT 5000 PLF OR LESS DO NOT REQUIRE SHEAR REINFORCING, 3. ALL WALL OPENINGS ARE TO HAVE A MIN, OF 24" OF CONCRETE WALL BETWEEN THEM. ADJACENT 6-FOOT WIDE MAX. OPENINGS MAY HAVE A MINIMUM OF 12" OF CONCRETE WALL BETWEEN THEM. 4. PLACE AN ADDITIONAL (1) 45 BAR VERTICAL OR A TOTAL OF (1) 46 BAR VERTICAL FULL HEIGHT EACH SIDE OF ALL OPENINGS. 5. SEE SB-1 FOR FURTHER NOTES AND CONSTRUCTION GUIDELINES. 6, SPECIAL REVIEW IS REQUIRED FOR LINTELS BEYOND THESE LIMITS. MATERIALS CONCRETE: 3500 PSI @ 28 DAYS AGGREGATE; WALLS - 3/4." MAX HORIZONTAL REINFORCEMENT; ASTM A615 GRADE 60 SHEAR REINFORCEMENT; ASTM A615 GRADE 60 LOADS LIVE LOAD; 42 PSF ROOF MAX. LIVE LOAD; 40 PSF FLOOR DEAD LOAD;15 PSF ROOF. DEAD LOAD; 12 PSF FLOOR WIND LOAD; 90 MPH EXPOSURE B 7. LOADS SHOWN ARE IN ADDITION TO LINTEL I v SELFWEIGHT, a (1) 45 HORIZONTAL I I BAR @ TOP OF LINTEL 1 yl' 43 S-HOOK : M SHEAR REINF. iu @ 18" O.C. I a I. 1° HORIZONTAL REBAR I @ BOTTOM OF LINTEL SEE TABLE 5 Me ., MIN, TYPICAL CONCRETE LINTEL HORIZ LINTEL SPAN IN FEET BARS 4 5 6 7 8 9 10 12 14 16 18 (1)45 6000 6000 4700 3400 2500 1900 1500 1000 700 400 300 (2)45 6000 6000 6000 6000 5200 4100 3300 2200 1600 1100 800 FOR AND THICKER LINTELS 2006 MASTER INSULATED CONCRETE ADVANCED WALL SYSTEMS, INC. FORM ABOVE GRADE WALL DRAWINGS 16927231st AVENUE NW, BIG LAKE, MN 55309 LINTEL SECTION AND REINFORCEMENT TABLE Phone: (763) 263-8512 Fax: (763) 263-5912 5201 EaaIRlver Road Suite 308 Minneapolla. Minneaola 55,121 Phone: 9635712500 Fax: 763.91.1166 05,adk 0¢YOY Late. - Fargo - AYrneapofs. Sion FaAs web: www.ultep.mm engineers pawn By: Troy Oeemo, Checked By: Trevor M. AMoyad By: Cmig owed JOB SITE INFORMATION (lo Ce filled out by t" conhadar) Street Addreee: dtbax ele: City' Stater Zip Code Can.: ja x 2051n. 10513% 3 SB-8B Shele, t9 of '20 NOTES 1, MINIMUM WINDOW WELL SIZE TO BE 36" x 36" INSIDE. MAXIMUM WINDOW WELL SIZE TO BE 40" x 72" INSIDE. 2. PERPENDICULAR WALLS TO HAVE LAPPED HOOK BARS AROUND CORNERS AND INTO BASEMENT WALL. 3. JAMB EACH SIDE OF OPENING TO HAVE ADDITIONAL (1) 05 BAR MINIMUM FULL HEIGHT, 4. CARE 1S TO BE TAKEN DURING BACKFILLING TO MAINTAIN A PLUMB WALL ALIGNMENT, BRACE AS REQUIRED. 5. SEE SB-1 FOR FURTHER NOTES & CONSTRUCTION GUIDELINES. 6. LADDER OR ALTERNATIVE MEANS OF ESCAPE TO BE IN ACCORDANCE WITH THE rnnr. WINDOW WELL SLOPE GRADE AWAY FROM 8711 FOUNDATION 6" WALL HOR1Z. BARS 44 @ 12" O.C. CENTERED IN WALL 8" WALL HOR1Z. BARS -? NONE REQUIRED #4 VERTS. @ 48" O.C. TYP. GRANULAR - MATERIAL 04 x 2'-0" DOWELS @ CORNERS OF WELL ONLY (5' MIN, EMBED) 12" WIDE x 8" THICK STRIP FOOTING (MIN,) MATERIALS CONCRETE: 3500 PSI @ 28 DAYS AGGREGATE: FTG - 11/2" MAX WALLS - 3/4" MAX REINFORCING; ASTM A615 GRADE 60 3' -0.1 MIN. FLOOR SYSTEM BY OTHERS CONCRETE LINTEL \ SEE SB-8 FOR 0 7 DETAILING WALL BEYOND (1) 44 HORIZONTAL 6" MIN. BAR OW CIP OR OPENING K 1CF WALL DPE m f 6" MIN. 1CF WALL SEE WALL SECTIONS =II FOR REINFORCEMENT a 2? -X - - ?. ? FLOOR SLAB a SEE NOTE 3 FOR JAMB REINFORCEMENT CONCRETE STRIP FOOTING SEE SHEET SB-1D PROVIDE CODE REQUIRED FROST PROTECTION TO BOTTOM OF FOOTING WALL SECTION WINDOW WELL 2006 MASTER INSULATED CONCRETE ADVANCED WALL SYSTEMS, INC. FORM BELOW GRADE WALL DRAWINGS 16927231st AVENUE NW, BIG LAKE, MN55309 WINDOW WELL SECTION Phone: (763) 263-8512 Fax: (763) 263-5912 5201 East Rrver Road Suile 308 Minnaapollb, Minnesota 55421 Phone: 763,571,2500 Fax: 763,571 1166 Bismarek-Datrovlakes'F81pa' Marrea,es-Sign Fa115 Wet: e. men, Pam engineers Drawn fly: 7h, De Groot Checked By: Trevor Axner Approved By. Craig Orwell I lNumber: Janu; Dare, Zip Code: Sneers: SB-9 JOB SITE INFORMATION po be filled out by the contactor Street Adorers: S LL) Uy 32 4 _ 199cv4 DRAINAGE AND UTILITY EASEMENT THIS INDENTURE, made and entered into this 214?- day of , 1987, by and between OTTO G. BONESTROO, unmarried, ROBERT W. ROSENE and JOYCE H. ROSENE, husband and wife, JOSEPH C. ANDERLIK and ELIZABETH A. ANDERLIK, husband and wife as Grantors, and the CITY OF EAGAN, Dakota County, Minnesota, as Grantee, WITNESSETH WHEREAS, said Grantors, in consideration of One Dollar ($1.00) and other good and valuable consideration, to them paid by Grantee, receipt of which is hereby acknowledged, hereby grant an easement to said Grantee, its heirs and assigns, for permanent drainage purposes, including the normal practice of filling with water from storm sewer runoff, and for utility line purposes over a tract of land 5.00 feet in width adjacent to and southeasterly of a line described as follows: Commencing at the southerly common lot corner between Lot 6 and Lot 7, Block 2, The Safari Third Addition according to the recorded plat thereof, Dakota County, Minnesota, thence South 41 degrees 17 minutes 30 seconds East (assumed bearing) along the southwesterly line of said Lot 7, a distance of 6.41 feet to the point of beginning; thence North 44 degrees 02 minutes 50 seconds East a distance of 148.12 feet; thence North 32 degrees 13 minutes 12 seconds East a distance of 31.17 feet to the northerly common lot corner between said Lot 6 and Lot 7 and there terminating. The Grantee shall have the right to do whatever is necessary for the enjoyment of the rights herein granted, including the right of clearing the easement area to allow for the use of the land as stated herein, and for ingress and egress to and from said tract of land and over and across said easement only for the purpose of constructing and maintaining, operating and repairing said drainage facilities and utility lines. And the said Grantors, for themselves, their heirs, executors, administrators and assigns do hereby release the said CITY OF EAGAN, its successors and assigns, from all claims for any and all damages resulting to said land by reason of the location of said drainage easement and utility lines. By acceptance of these easements, the Grantee agrees that it shall restore the property located outside the anticipated perimeter of moving water to as near the existing grade as is reasonably possible and further agrees to replace existing cultivated shrubs or sod and to seed all other areas not covered with moving water. IN WITNESS WHEREOF, the Grantors have hereunto set their hands and seals the day and year first above written. Jif ?JAitJ Otto G•. B estroo W&I -,j ? - Robert W. Rosene J H. Rosene Jos ph C. Anderlik El' beth A. Anderlik STATE OF MINNESOTA) / ss. COUNTY OF ?,J? ) On this ?? day of ? 1W, before me a Notary Public within and for said County, personally appeared OTTO G. BONESTR00, unmarried, to me personally known to be the person described in and who executed the foregoing instrument and acknowledged that he executed the same as his free act and deed. Asub M. E 11" 11 Notary FLblic-M. esota ( "`CCC..000C...I'??Mll ..-•• Washington County . Notary Public .c. M Ccmmissian Expires - November 15: 19W STATE OF MINNESOTA) ss. COUNTY OF ) On this o2 day_, of , 19U, before me a Notary Public within and for--said County, personally appeared ROBERT W. ROSENE and JOYCE H. ROSENE, husband and wife, to me personally known to be the-persons described -in and- who executed: the foregoing instrument, and acknowledged that they executed the "same as their free act and deed. y?/ Q: S EA A L) Rive. /l?? ? vC? G(? lic Notary Public SUSAN M. EBmm ` Notary PUMk-Minnesoh +.• Washington County '.a= Mq Ccmnossion Extern November 15, 19% STATE OF MINNESOTA) ? ss. COUNTY OF O(G+44/ ) On this f day of 19 97, before me a Notary Public within and for said County, personally appeared JOSEPH C. ANDERLIK and ELIZABETH A. ANDERLIK, husband and wife, to me personally known to be the persons described in and who executed the foregoing instrument and acknowledged that they executed the same as their free act and deed. 1', P 2L Tj SUSAN M. FBERIIN Notary Public Notary Public-Mimiesbd 1c WashmRlon County My Ccmmission ExDUes November 15, 1950 THIS DOCUMENT DRAFTED BY: Hauge, Eide & Keller, P.A. 1260 Yankee Doodle Road, #200 Town Centre Professional Bldg, Eagan, MN 55123 (612) 956-9000 EXEMPT FROM STATE DEED TAX STAMPS c Certificate For: Sheet 1 of 3 Bonestroo Rosene Anderlik 6 Associates 2335 West Highway 36 St. Paul, MN 55114 10-22-86 11-1Y-86 DELMAR H. SCHWANZ L*,m rw...ero.. W- •.rrrr U WW Um r tr rr 0 mmn r UMSOYT"WORRTTRAL -p0*NWWff.N NIMTANN" 4124th N OZ ? i?C ?1 . h M o ? h 07=? 9 ,v r? gyn. ? Q O sz o/ UMV[110R'S CERTWWATI G y y Y 0 W i N M GI .Gi I +r 0 A ~ ti 9 d 0 N o ro 3 ? a 8 8E" u .+ o s I u 0 W as to d ? / or c w r -m g?y fa .0 to Aj to U " 41 4-j \ U \ W Yl Y 1 0 W N rd ,q 4 ) w, 4 ) 4 ) \ r4 N \ \ ? 111 ?v Ti e y r c9 y ? ?? ? O F QqN R N Nu O 10 ,T. 3 i -S /£p o if„ ?` I O ?Z/ 0/0 0/v °c ,10 0 \1 8 H F M N x? y s? '`Ny O (? V _r V a w 0 xe ro T N WNN[BOTA M01fTNAY1004 NO. NN V) 4 G 4r Y _ Q N v D V1 R tt ? O nD , ,? 1 i DD YAS 15=^"b ®rm? 1964 SAFARI TRAIL Denotes set spike "n Slopa o Denotes set iron monument orRoWning WaILWAI- 0 Denotes found iron monument R x927.6 Denotes existing elevation o-- ( 930.0) Denotes proposed elevation Denotes proposed drainage / TC Denotes top of curb B 1 jlk TNH- LOT 7 BLOCK 2 Bench Mark: 953.86 _ SAFARI TRAIL Proposed Garage Floor= 957.8 Proposed Garage Top of Block= 958.2 Proposed House Top of Block= 958.2 Proposed Low Floor= 949.2 PROPOSED HOUSE = 3,253 SQ. FT. OR 17.0% OF LOT AREA X DRIVEWAY = 1033 SQ. FT. \ ??\ P/0 LOT 7 = 19,172 SQ. FT. As-Atu&-!?eeVeq Je? 3HGl6t?e {?'? 5,,. sera- Elgo. 2LCW, Rc-k"hi-f wa//mr yf`O? d0 ?Q ?CC/? 9op? in Es ! 1k C A)tw NatiSG Fl¢J. CRw'r?d C? 0 Chrml_4ed Sal heW4-4-?_k P i` O? 19 co So ???? of / A9 0 p FSp ?i// ??C ? S/ 1 c°???? F?F e93 Aq?? ?? 11 ' tp .°3F 4} O hd / n i ? )o a n n sS4 4 .?1 (sue -• =S^__ moo' ? si3 \?9 ? ORptN ENZ pER 0-N lSS A ;'! EPSEM ?. i 954.0 u O 5C3 EROSION SAFARI s®RM.H. TRAIL 4- R?6 Jr? o • 00 5 X60 ?8?7'49" MEgg y/ a,? s ,? ?? X36 ? ?6 moo Yeize? ,?• BS?S) ?o l 9S> 3x LOT 7, 95 6.v 957 a ((955.0) x Property Description 4' PINE* ?C r? J That part of Lot 7, Block 2, The Safari Third Addition,)according to the recorded plat thereof, 'Daxora rvrmnesoua, rYCIr f roar pMT of f,uf f described as follows: Beginning at the northwest comer of said Lot 7; thence South 44 degrees 02 minutes 50 seconds West (assumed bearing) along the westerly line of said Lot 7 a distance of 178.11 feet to the southwesterly comer of said Lot 7; thence South 41 degrees 17 minutes 30 seconds East along the southwesterly line of said Lot 7 a distance of 6.41 feet; thence North 44 degrees 02 minutes 50 seconds East, parallel with the westerly line of said Lot 7, a distance of 148.12 feet; thence North 32 degrees 13 minutes 12 seconds East a distance of 31.17 feet to the point of beginning, Dakota County, Minnesota We hereby certify that this is a true and correct survey of the above described property and that it was performed by me or under my direct supervision and that I am a duly Licensed Surveyor under the laws of the State of Minnesota. That this survey does not r purport to show all improvements, easements or encroachments, to the property except as shown thereon. s Q 44, 2007 yb . Signed this day of -- it y r ?s l, By: John L. Benner, Minnesota L.S. No. 26708 CqR ? 1 a 1 c`°r; . ? ? N o ". W P. s S7 ? ?I ? 1 m o° 1 1 x(956 ?? 1 COQ &t E, W-1 ED -r 1 1 r- By, I /1 n l I r l L_ \ '` at n I ??a¢? /'l LJ LJ I I I ?J I v EAG& EIS ?G DEPT. L Notes: p 1. Building dimensions shown are for p m W horizontal & vertical placement of structure only. See architectural plans for building o & foundation dimensions. Z 2. No specific soils investigation has been (Tl completed on this lot by James R. Hill, Inc. N The suitability of soils to support the specific C N Thouse proposed is not the responsibility of M n J MQJames R. Hill, Inc. or the surveyor. O 0~ Z3. No specific title search for existence or non- y m existence of recorded or un-recorded easements g 0 has been conducted by the surveyor as a part of this survey. Only easements per the recorded y' plat are shown. Z 4. Proposed grades shown were taken from the grading &/or development plan prepared by JAMES R. HILL. INC. SCALE IN FEET 0 30 60 90 1 inch = 30 feet SAN. SERVICE INVERT ELEV.=TO BE DETERMINED C (X _ at N •? Ln r i1 • W m4 C.D A? WON ZE 3.i W `zop I I U3 O U DRAWN BY RWD DATE 2/06/07 REVISIONS CAD FILE 270028 PROJECT NO. 270028 FILE NO. FOLDER SHEET 1 OF 1 D M RIMU ED 1964 SAFARI TRAIL Denotes set spike 9:1 AASATIUM Slopes o Denotes set iron monument or Retaining Wall Will • Denotes found iron monument Be Required tau x927.6 Denotes existing elevation 4 Denotes proposed elevation I ??'-- (930.0) Denotes proposed drainage f pS `I;- 1i (Q®g?®m SAFARI TC Denotes top of curb ; 1 ?? U Q1 O M.H. TR A 1 L 1i?e Sew ?`???? r? ?- ? ? TNH- LOT 7 BLOCK 2' Bench Mark: 95 3.86 - SAFARI TRAIL Q ?O •? o ?F`t o?'?jO?Q?\ Proposed Garage Floor= 957.8 o ? c, ??v r?1 Proposed Garage Top of Block= 958.2 958 2 C' N• 'S ?' Proposed House Top of Block= . ?• ; - % Proposed Low Floor= 949.2 ,? ToQtic ` PROPOSED HOUSE = 3,253 SQ. FT. r C,i G OR 17.0% OF LOT AREA X \ ?C 'J? DRIVEWAY = 1033 SQ. FT. ' P/O LOT 7 = 19,172 SQ. FT. \\ °h? A A v oo oL \ ??2 °F / 79 NF co / 01Z 61 19 d?S 060 00 47' ? 0 85 P °? ?2 MEAS 1 i WATER SEe .? 4q OR OPOSe[ i .236 0 p SWAY s a? 60%I Ve Ze?i n (95j5 0? ?? 5, 61 ?Rqi 88 ry1 ?? o ?1t s ?> I M?1` 14-0 1 ° \ PRO'e .r85' 11`f 1 H USSei (9 12 3 3 575 ) LOT 7 9se6x x 95j 8 --?_ (955 0) x / ?' ?moo°°' ,o ? ry. ? n 54 0 4 ? (sue s v. ?/ cu \ AINPGE PER PLAT `Oy mss \-a-;?EpSEV`EN?? ?' SSA ?`' LP - I n T A 0 T i i r- \ I F IL 95> 3x bearing) along the westerly line of said Lot 7 a distance of 178.11 feet to the southwesterly comer N76' That part of Lot 7, Block 2, The Safari Third Addition, according to the recorded plat thereof, Dakota County, Minnesota, EXCEPT that part of Lot 7 described as follows: Beginning at the northwest comer of said Lot 7; thence South 44 degrees 02 minutes 50 seconds West (assumed of said Lot 7; thence South 41 degrees 17 minutes 30 seconds East along the southwesterly line of said Lot 7 a distance of 6.41 feet; thence North 44 degrees 02 minutes 50 seconds East, parallel with the westerly line of said Lot 7, a distance of 148.12 feet; thence North 32 degrees 13 minutes 12 seconds East a distance of 31.17 feet to the point of beginning, Dakota County, Minnesota- .0 / r? J? 0F-PG?o95 6k We hereby certify that this is a true and correct survey of the above described property and that it was performed by me or under my direct supervision and that I am a duly Licensed Surveyor under the laws of the State of Minnesota. That this survey does not purport to show all improvements, easements or encroachments, to the property except as shown thereon. Signed this /441, day of _______, 2007. By. "John L. Benner, Minnesota L.S. No. 26708 ?5?house proposed is not the responsibility of S 3. No specific title search for existence or non- M existence of recorded or un-recorded easements has been conducted by the surveyor as a part Notes: 1. Building dimensions shown are for horizontal & vertical placement of structure .?. only. See architectural plans for building CIO h \ & foundation dimensions. ? 2. No specific soils investigation has been completed on this lot by James R. Hill, Inc. The suitability of soils to support the specific 671G)James R. Hill, Inc. or the surveyor. of this survey. Only easements per the recorded plat are shown. 4. Proposed grades shown were token from the grading &/or development plan prepared by JAMES R. HILL, INC. Property Description M ^ \ v o ` = o, Z 0 W W CO. 11 ?L 5 co 1-14 Z W r\ 0 N M J J cm r 0 /z rn SCALE IN FEET 0 30 60 90 1 inch = 30 feet mgm:g Iona a cc MOD SAN. SERVICE INVERT ELEV.=TO BE DETERMINED N N N ?iZ w` W a bzI z35? aN°xaax O c.? 270028 FILE NO. DRAWN BY RWD DATE 2/os/o7 REVISIONS CAD FILE PROJECT NO. 270028 FOLDER SHEET 1 OF 1 SCOPE: MATERIALS LOADS DESIGN OF I.C.F. LINTELS AND CONCRETE FOOTINGS, AS WELL CONCRETE: F'c = 3500 PSI @ 28 DAYS LIVE LOAD: 35 PSF ROOF AS A PLAN REVIEW OF I.C.F. WALL CONSTRUCTION FOR A REINFORCING STEEL: ASTM A615 GRADE 60 LIVE LOAD: 40 PSF FLOOR PROPOSED RESIDENCE. CONSTRUCTION IS TO BE DONE IN STEEL: I-BEAMS Fy = 50 KSI DEAD LOAD: 15 PSF ROOF ACCORDANCE WITH THESE DRAWINGS AND STANDARD AGGREGATE: FOOTINGS - 1 112" DEAD LOAD: 15 PSF FLOOR INDUSTRY PRACTICE. WALLS - 3/4" WIND LOAD: 90 MPH EXPOSURE B NOTES: _ ?? BACKFILL: CLAY (GROUP III) CODES 1 ,,-REFER-TO ADVANCE WALL SYSTEMS 200&rF MASTER EFFECTIVE PRESSURE = 60 PCF/FT ACTIVE 2003 MINNESOTA STATE BUILDING CODE DRAWINGS PREPARED. BY_.ULTEIG-ENGINEERS-FORS W/ AMMENDED 2000 IBC/IRC MORE INFORM ATIONI THE DETAILS REMAIN ALLOWABLE SOIL BEARING: 2000 PSF (ASSUMED) APPLICABLE TO CURRENT CODES. ADVANCE WALL SYSTEMS WILL BE ISSUED 2007 MASTER DRAWINGS UPON COMPLETION. THE 2006 DRAWINGS ARE AUTHORIZED TO BE USED IN CONJUNCTION WITH THESE SITE SPECIFIC ELEMENTS. 2. THESE DOCUMENTS APPLY TO STRUCTURAL ONLY. REFER TO ARCHITECTURAL DRAWINGS PREPARED BY PHILLIPS PLANNING FOR MORE INFORMATION, 3. DRAIN TILE, DAMPPROOFING AND/OR WATERPROOFING, & INSULATION, AS WELL AS THEIR INSTALLATION, ARE TO BE IN ACCORDANCE WITH THE CODE. 4. BAR SPLICES ARE TO BE LAPPED A MINIMUM OF 48 BAR DIAMETERS. 5. PROVIDE MATCHING HOOK BARS FOR ALL HORIZONTAL BARS AT ALL WALL CORNERS AND INTERSECTIONS. LAP HOOKS IN ACCORDANCE WITH NOTE 4. 6. CONTRACTOR AND BUILDER ARE TO VERIFY ALL CONDITIONS SHOWN. NOTIFY ENGINEER IS DISCREPENCIES ARISE PRIOR TO PROCEEDING WITH THE AFFECTED WORK. 7. ADEQUATE SHORING / BRACING IS THE RESPONSIBILITY OF THE CONTRACTOR. 8. PLEASE PROVIDE ULTEIG w/ A ROOF AND FLOOR TRUSS LAYOUT ONCE AVAILABLE FOR FINAL REVIEW OF BEARING LOCATIONS. THE DESIGN OF ALL WOOD TRUSSES, BEAMS, AND CONNECTIONS IS BY THE MANUFACTURER. 9. HOUSE FOUNDATION WALLS HAVE A 9'-0" CLEAR HEIGHT. THE DESIGN HEIGHT USING A 2x10 LEDGER WITH THE BOTTOM OF THE LEDGER EVEN WITH THE BOTTOM OF THE MIDDLE-CHORD BEARING FLOOR TRUSSES IS 9'-10". GRADE IS TO BE KEPT A MINIMUM OF 8" BELOW THE TOP OF THE LEDGER. THE WALLS SUPPORTING FULL GRADE ARE TO BE 13" CIF w/ AN 8" CONCRETE PORTION REINFORCED w/ EITHER #5 VERTICAL BARS @ 18" O.C. OR #6 VERTICAL BARS @ 24" O.C. LOCATED ty" FROM THE INSIDE FACE. REFER TO SB-2C-FOR ALL OTHER CONSTRUCTION INFORMATION. BELOW THE STOOP SLAB-ON-GRADE, THE CONTRACTOR IS TO BACKFILL WITH A MINIMUM OF FOUR FEET OF GRANULAR MATERIAL. 1., ?i l Advance Wall Systems, Inc. 16927 231st Avenue NW Big Lake, MN 55309 A.... d Dale Deednp0pn GENERAL NOTES & FOUNDATION PLAN )q611 hereby,or, Nal Inbplan,apadloatlodardebad wax prepared by me ar under my Errec1 iuperrision and IIIa1I adult' exdional Ergineer under the le Mws Anne State of Minnerand Not Mama: Trevor Axner Sgned: Date: 4/19/07 Udenx Number: 45470 engineers 5201 Ent RNer Road Suite 308 Minneapolis, M-rennle'55421 Pb00e7635712500 Fax: 763511,1160 Web'. wwwulleigcom Bathar&-DajddUkax-Ferpo,Mndo=lie Sioux Falls Drawn By. RPM Cracked! By RPM Apphwad By: TRP Swedberg Residence Safari Trail 116Y Eagan, MN CONCRETE PAD FOOTING TABLE MARK SIZE REINFORCEMENT F1 -6" x ' " NONE ' X 1 -0 F2 Y-0" X Y-0" (3) 44 HORIZ. BARS X I'-0" EACH WAY 4'-6 x 3'-0" (3) "4 LONGITUDINAL F3 x BARS & ($) A4 TRANSVERSE BARS EVENLY SPACE REBAR AND PLACE 3" FROM BOTTOM OF PAD FOOTING. PLACE PAD FOOTINGS MONOLITHICALLY WITH STRIP FOOTINGS AS APPLICABLE. `ALL PADS MAY BE 14" THICK UNREINFORCED ButLDING YV4,rev I 1W. - -- PnOx NunLer 207,OH3 Dale. Aera Is. 2007 `- she.% I of 3 J (1) #4 HORIZ. (1) #4 HORIZ. _- (1) #4 HORIZ (1) #4 HORIZ. BAR AT TOP d (1) #4 HORIZ. BAR AT TOP . BAR AT OP BAR AT TOP OF LINTEL BAR AT TOP ° OF LINTEL OFLINTEL OF LINTEL OF LINTEL ? ; b #3 SHEAR REINF- I Z a ? #3 SHEAR REINF. a ) I Z N cli @ 12" O.C. 1 /) r @ 12" O.C. o i A Y N )(1)#5HORIZ. () #5 HORIZ. BAR AT (2) #5 HORIZ. ? (1)#5HORIZ. BAR AT Is I/ (2) #5 HORIZ. /I' I BAR AT B T BOTTOM BARS @ BOTTOM BARS @ / O TOM MIN4" . Li 12 LINTEL 0 4" MIN' L2 LINTEL BOTTOM 4" L3 ° 6" M L4 BOTTOM M6" L5 24 24 LINTEL 24 LINTE L 24 LINTEL EL I w ' TABLE I\Y' 1. HORIZONTAL REINFORCING IS TO BE CENTERED IN WALL EXTEND A MINIMUM OF 24" PAST THE OPENING AT EACH END. 2. PLACE A MINIMUM OF (2) #4 OR (1) #6 VERTICAL BARS FULL HEIGHT EACH SIDE OF ALL OPENINGS. CONCRETE BETWEEN ADJACENT OPENINGS IS TO HAVE MIN. (4) #4 OR (2) #6 VERTICAL BARS TOTAL. CENTER BARS IN WALL THICKNESS. Advance Wall Systems, Inc. 16927 231st Avenue NW Big Lake, MN 55309 Revision Dale Deso ption MAIN LEVEL PLANS & LINTEL DETAILS I hereby out that this plan. saddhoatipn m report Was prepared by me or under my slowed supervision and that I am a duly Licensed Professional Passional under the laws of the State of Minnesota. Print Name: TreVOr A%D r &,art, ' Advance Wall Systems, Inc. 16927 231st Avenue NW Big Lake, MN 55309 Revision Date Desdhptipn . WOOD HAND-FRAMING BY OTHERS 4 E r a ? a 21""' ' ' 1 . ,.._., :.....?. _ _ UPPER LEVEL PLAN & WALL ELEVATIONS I hereby comfy that this plan, spacrlicetlpn ormppd as prepared by me or under my cored supervision and that I am o duly Licensed Pmtesseii E,hewr under the laws of Ibe State of Minnesota. - Print Name: TraV/OIr A%Der Signed: V/ oate"4/19/07 License umber: 45470 r PROVIDE MIN. 8 X4 E f L1 G engineers t i CONCR TE COLUMNS w/ (1) #5 VERTICAL BAR I Q t k k 5201 East River Rovil Bull, 336 M M v .V? Li dp J F : From: 1168 00 Fa 763 511 571 2 63 FLOOR ,SPACE n PLAN LAYOUT II 7m3apo b ..,[to ? Sipuxf is a rma<k 2F s Fa, Dirtier 3 S3 ARCHITECTURAL 2ND FLOOR PLAN SHOWN Drawn By RPM hocked 9y: RPM Approved By: THA ELEVATION Swed6erg Residence S3 Safari Trail Eagan, MN r : f Nu er. 2070443 ^ 7 43 D b 4 Dote: Anri11 ` V sheets. 3 of 3 City otEapn 3830 Pilot Knob Road Eagan MN 55122 Phone: (651) 675-5675 Fax: (651) 675-5694 RECEIVED JAN 1 1 2011 2011 RESIDENTIAL BUILDING PERMIT APPLICATION z i( Use BLUE or BLACK Ink Permit#: q -7-6V Permit Fee: / • Date Received: / r,/ 1/ Staff: Date: /4/ —/ / Site Address: 7661 Tenant: /('t f K 4,47-SDA....) Suite #: RESIDENT / OWNER Name: A -'I / Kr li,f14.S0 Phone: 97 5)- .5.)-rs--s Address / City / Zip: /C6 S`+ 7�Q', ,,' Applicant is: x Owner Contractor TYPE OF WORK Description of work: 00,-...-71,471--;6—, cd .S`f,‘✓ c_7 `- . Construction Cost: # 70 K Multi -Family Building: (Yes / No ) ) CONTRACTOR Name: mss'-=----` License #: Address: City: State: Zip: Phone: Contact: Email: COMPLETE In the last 12 months, has No If yes, THIS AREA ONLY IF CONSTRUCTING A NEW BUILDING the City of Eagan issued a permit for a similar plan based on a master plan? date and address of master plan: _Yes Licensed Plumber: 7() pig ...,cij Phone: �'f 5?,- 36-7- - ��68 Mechanical Contractor: Ulpc ✓`rA�/�-- WA --1'.►..,/ Ls,f Phone: Sewer & Water Contractor: r Phone: NOTE: Plans and, supporting, documents that you submit are considered to be public information.Portions of;,. the information may be classified as non-public if you provide specific reasons that would permit the :City to conclude that they are trade secrets. CALL BEFORE YOU DIG. Call Gopher State One CaII at (651) 454-0002 for protection against underground utility damage. Call 48 hours before you intend to dig to receive locates of underground utilities. www.qopherstateonecall.orq I hereby acknowledge that this information is complete and accurate; that the work will be in conformance with the ordinances and codes of the City of Eagan; that I understand this is not a permit, but only an application for a permit, and work is not to start without a permi ; that the work will be in accordance with the approved plan in the case of work which requires a review and approval of plans. Applicant's Printed Name Page 1 of 3 DO NOT WRITE BELOW THIS LINE SUB TYPES Foundation ySingle Family Multi 01 of_Plex Accessory Building WORK TYP New Addition Alteration Replace Retaining Wall DESCRIPTION Valuation Plan Review Fireplace Garage Deck Lower Level Porch (3 -Season) Porch (4 -Season) Porch (Screen/Gazebo/Pergola) Pool F N O1-' // rr Interior Improvement Move Building Fire Repair Repair 9(60 ,025%_ 100%0) Census Code # of Units * of Buildings Type of Construction V 6 REQUIRED INSPECTIONS Footings (New Building), Footings (Deck) Footings (Addition) Foundation Drain Tile Roof: Ice & Water __-Final Framing Fireplace: _Rough In __Air Test Insulation Meter Size: Reviewed By: Occupancy Code Edition Zoning Stories Square Feet Length Width Siding Storm Damage Exterior Alteration (Single Family) Exterior Alteration (Multi) Miscellaneous 77 qq(to Demolish Building* Reroof Demolish Interior Windows _ Demolish Foundation Egress Window Water Damage *Demolition of entire building — give PCA handout to applicant 4414-007 Final MCES System SAC Units City Water Booster Pump PRV Fire Sprinklers Sheetrock X- Final / C.O. Required Final / No C.O. Required HVAC Other: Pool: __Footings Air/Gas Tests Fina Siding: Stucco Lath Stone Lath Brick Windows Retaining Wall: _ Footings _ Backfill _!Final Radon Control Erosion Control , Building Inspector RESIDENTIAL FEES Base Fee Surcharge Plan Review MCES SAC City SAC Utility Connection Charge S&W Permit & Surcharge Treatment Rant Copies TOTAL rW.5(11 )4190 el/yr,/ r, 1,V-vieo eAt ( 9,012-9 Page 2 of 2 ` Use BLUE or BLACK Ink f I For Office Use I Permit 1 City of Ea 1 , I Permit Fee: I 3830 Pilot Knob Road 0115113- I Eagan MN 55122 I Date Received: 1 Phone: (651) 675-5675 1 I Fax: (651) 675-5694 1 Staff: I I I 2013 RESIDENTIAL BUILDING PERMIT APPLICATION Date: Site Address: L, Unit Name: ~ IE RI~~_ LAJ?_.<44 Phone: Resident! ~ ( Owner Address/ City /Zip: 1 (A Aen~ 7PAIL- abvW Applicant is: Owner Contractor T Of Work Description of work: ~ Ye~ ySf OI~S~~ Ype Multi-Family Building: (Yes / No Construction Cost: * X0 Company: U~c-ll.FJN'!S Use, Contact: Address: L ~L `ii /~?~~1~! L City: OW-m4hill I Contractor State: Zip: Z.Z Phone: tY~ Z '70~-1 i License Lead Certificate If the project is exempt from lead certification, please explain why: (see Page 3 for additional information) 00 COMPLETE THIS AREA ONLY IF CONSTRUCTING A NEW BUILDING i In the last 12 months, has the City of Eagan issued a permit for a similar plan based on a master plan? _Yes _No If yes, date and address of master plan: Licensed Plumber: Phone: Mechanical Contractor: Phone: I I Sewer & Water Contractor: Phone: NOTE: Plans and supporting documents that you submit are considered to be public information. Portions of a the information may be classified as non-public if you provide specific reasons that would permit the City to .a conclude that they are trade secrets. CALL BEFORE YOU DIG. Call Gopher State One Call at (651) 454-0002 for protection against underground utility damage. Call 48 hours before you intend to dig to receive locates of underground utilities. www.gol)herstateonecall.org I hereby acknowledge that this information is complete and accurate; that the work will be in conformance with the ordinances and codes of the City of Eagan; that I understand this is not a permit, but only an application for a permit, and work is not to start without a permit; that the work will be in accordance with the approved plan in the case of work which requires a review and approval of plans. Exterior work authorized by a building permit issued in accordance with the Minnesota S to Building Codelmisl be co pleted within 180 days of permit issuance. X x -91 e~,, M&Kzi O-J/ Applicant's Pri ted Name A cant's Sig tur Page 1 of 3 1~~77~ In Tr- DO NOT WRITE BELOW THIS LINE //,5/ SUB TYPES Foundation Fireplace Porch (3-Season) _ Exterior Alteration (Single Family) Single Family _ Garage _ Porch (4-Season) _ Exterior Alteration (Multi) Multi Deck _ Porch (Screen/Gazebo/Pergola) _ Miscellaneous 01 of - Plex Lower Level Pool Accessory Building WORK TYPES New Interior Improvement _ Siding _ Demolish Building* Addition Move Building _ Reroof _ Demolish Interior Alteration Fire Repair - Windows _ Demolish Foundation Replace _ Repair _ Egress Window _ Water Damage Retaining Wall *Demolition of entire building - give PCA handout to applicant DESCRIPTION Valuation Occupancy t~ MCES System Plan Review Code Edition ' -:)I SAC Units (25%_ 100% Zoning City Water Census Code Stories Booster Pump # of Units Square Feet PRV # of Buildings Length Fire Sprinklers Type of Construction Width REQUIRED INSPECTIONS Footings (New Building) Meter Size: Footings (Deck) Final / C.O. Required Footings (Addition) Final/ No C.O. Required Foundation HVAC Gas Service Test Gas Line Air Test Drain Tile Other: Roof: -Ice & Water -Final Pool: -Footings -Air/Gas Tests -Final Framing Siding: -Stucco Lath -Stone Lath -Brick Fireplace: -Rough In -Air Test -Final Windows Insulation Retaining Wall: _ Footings _ Backfill _ Final Sheathing Radon Control Sheetrock Erosion Control Reviewed By: , Building Inspector RESIDENTIAL FEES R~ ~f oil Base Fee 0(, Surcharge 0 Plan Review MCES SAC City SAC , /K ! ~ a C7 ~ u C~ Utility Connection Charge x S&W Permit & Surcharge Treatment Plant Copies TOTAL Page 2 of 3 ~p7 0 Q O -u ~X D> .00 000 :3 C-) to U:) "D -0 -0 0 C~ ^ zs bto 0 0 O 000 3 O v ' -u to w w U) O^ y~~ / O y 0 O roll.. Q Q 00) y rn O O w T M J Ooo 6 / M s4; 9ee-a / ''vE+ 3 II ~i ° _ con :jE C~ 30, r 6 A d o roIn ~ ooaQQ©c~ f<;• o r- c roro rororororororo ° oD > > > o o c,, o O ~7 ---I ,n m o o -i -q rn 000000, 0 CD 0 1M 0 IM 0 CD \40 wwwowow Z M -D (D --I, Co 0 -Pa dc`s O D @ v o o- °c c~°- C 7 / ° ~0,~3 J- \ 0ic " W 0 n V10 000 CL M Lo U) 0 (n (D =v 5 it >14 o_D_ro o 3 ro 5Zo ' , r- i7• ro 0 C ~C~~/ O cv co ca ca o Q 3 416 •Sj ~~0,~ C/ cD oo •~o.v DN a'o 3 NNN00 M -v :3 3 3 c: CD 9> Cb 19 %3~ U, F.~s w„~~`~3ia tJ • ~j ~l~, r'o ti D 40 to r - Z m-A (A p / !v (9 / c0 I W k .10 0;0 :00 ti in lam -1631 v M 00 .0 %Z1 C4 ;Fo L" CD 0) N 70 1 10 9,00 v ti > a C)AI _0 lo, x r3 gS ,a~o•g D 'ro ~N 6 11A R~ 6 7 •L 'lS~~O'~A ~'d~ N P~ ~A N O C D Cn ,p !~Ly- Lr y o: w =r r- \ H it Z ~NOISIAIa SN01103dSNP JNicninE3 M a L4 (f- r 4JLZ) 1-7 •3i~►Q ~yC ro y CD CD 0 w o Cl) aw ° •o "ME w D o (n c a CD -ON. -O O CD W 3 C7 N O S O ro O ry rot rn N, n t- o -moo x• o o ~o o ~I acn~,o°'~ ~.~cRy° to Rp D rn c cD 3 , c I I , + w co t'"o a lfa 8- Cb CD en 'CJ Z C') • I 1 6n O CL C1 N D ~n t~. N • rn a o° m =3 zcn r- 03 c r1 ~ *~3ro0 O •Wa~c y o F SS 2 O CD N CD 0 O G . O C/) r+- r+ :3 wC co Ul ~G b` bi z 3 _°o CD ~-0 Q CL COD Co I ° o- tD r Cy 'vJ o ij''''d a • ~G Z,- C o O CD z O Cr CD ro I . r cn 6? co o w P ti. q CD A= q= O 7 cD 3 O ro C ro p N ca. p~ r Ou~ A cO~ a~ C I Z3~ N Q'C3 o oAoro o5 o' a O o _ C-) O a cD+ CL ~j! O O o_ (~D b N• c V y co ° r Z c0D C cZ CD CD o in' F. ' rn a I VI ° CD 6~x CD L) < to Q n a F), CD C 1 C ro in c@o o Z N y ° o Z -°v S cn `C o o CD CD < =r Co ° p' O ju' rt rr CD Q•t lZ o'er Cr Cpa O CD CD I- O O (D O f I (p co S 1c o r. p' . r C v ii (n 3 3 v? o u- m to Q x N O~ ro G d m o ~M o CD rn I -,,o n 11 cnDrorn 0 CL ro•~° o~ =3 0 CD C: a S -o g n cv -Q 8- o o CD . iA r+ cn " O 0 =r Gi ~ c av o ~ ° cn CD 0 CD CD "6 MM Q% -v ° x• (D c 3 o N I o rnc(D•opoa co ew54 o _ O CD C 4 5 I CD O O Z~ ~ W ro te 1 cD N~ .n o. Q '~g CD 1 -0 (n M Z 'v C1 CD O . O 5) 1 of d ' < O q c°u o• o o• < CD O CD n vOi S I N to quo.` vQ M *1 T3 ( O O o CD Cr CD 0 (OD M ccn N ° to o CD R c~9 c~v Q' Z] cn co _ 0 cD v i O o toi~ 0 y~ 1 . d=;, 0 o~° ~ M=-cr c c o 1 ogo .arn.,ynuaCD M O " -0 CD O O 2. j N ~ r- -K DD 1 N r•a N O C C~ P,, CL . CD O b o o M 10 N M CERTIFICATE OF SURE James R. Hill, Inc. c o a PLANNERS /ENGINEERS /SURVEYORS \ M z N -1 N 0 \ F01t: LMBY ff=BMG 2500 W. C1Y. ft 42, Sall 120, Bwww. MN 55337 O oD OD Z ° w PHONE: (952)890-6044 FAX' (952)690-6244 z 1264 SAFM1 ML 19 PHONE 43 94(763 792E & FAX (763)7M 2-157439 City of Eaaall 3830 Pilot Knob Road Eagan MN 55122 Phone: (651) 675-5675 Fax: (651) 675-5694 RECEIVED FEB 102014 Use BLUE or BLACK Ink For Office Use Permit #: Permit Fee: Date Received: Staff:: Zilo /let -X2,e(a 014 RESIDENTIIAL BUIL INQ PERMIT APPLICATION Date: '� _/(9.47'2°/V Sie Address: ` Unit #: Name: it/i( kte Resident/ Owner Type of Work Contractor Address / City / Zip: Applicant is: Description of work: Construction Cost: /qa Owner Phone: 95-,2 -,2%2 ' S-S� Contractor Company: Se. Address: State: Zip: Phone: License #: Multi -Family Building: (Yes / No Contact: City: Lead Certificate #: If the project is exempt from lead certification, please explain why: (see Page 3 for additional information) COMPLETE THIS AREA ONLY IF CONSTRUCTING A NEW BUILDING In the last 12 months, has the City of Eagan issued a permit for a similar plan based on a master plan? Yes No If yes, date and address of master plan: Licensed Plumber: Mechanical Contractor: Sewer & Water Contractor: Phone: Phone: Phone: NOTE: Plans and supporting documents that you submit are cohsidered to be public information. Portions of the information may be classified as non-public if you provide specific reasons that would permit the City to conclude that the are trade secrets. CALL BEFORE YOU DIG. Call Gopher State One Call at (651) 454-0002 for protection against underground utility damage. Call 48 hours before you intend to dig to receive locates of underground utilities. www.qopherstateonecall.orq I hereby acknowledge that this information is complete and accurate; that the work will be in conformance with the ordinances and codes of the City of Eagan; that I understand this is not a permit, but only an application for a permit, and work is not to start without a permit; that the work wit be in accordance with the approved plan in the case of work which requires a review and approval of plans. Exterior work authorized by a building permit issued in accordance with the Minnesota State Buildin• Co. - st be co r eted within 180 days of permit tiissuance. E /70? -r - Applicants Printed Name Applicanature Page 1 of 3 DO NOT WRITE BELOW THIS LINE SUB TYPES Foundation Fireplace Porch (3 -Season) Exterior Alteration (Single Family) Single Family Garage Porch (4 -Season) Exterior Alteration (Multi) Multi Deck Porch (Screen/Gazebo/Pergola) Miscellaneous 01 of _ Plex k Lower Level Pool Accessory Building WORK TYPES New Interior Improvement Siding Demolish Building* Addition Move Building Reroof Demolish Interior ✓f Alteration Fire Repair Windows Demolish Foundation Replace Repair Egress Window Water Damage Retaining Wall *Demolition of entire building - give PCA handout to applicant DESCRIPTION Valuation Plan Review (25%_ 100% {/ ) Census Code # of Units # of Buildings Type of Construction Occupancy Code Edition Zoning Stories Square Feet Length Width 2497 R-1 MCES System SAC Units City Water Booster Pump PRV Fire Sprinklers REQUIRED INSPECTIONS Footings (New Building) Meter Size: Footings (Deck) Final / C.O. Required Footings (Addition) ,$ Final / No C.O. Required Foundation �L. HVAC _ Gas Service Test Gas Line Air Test Roof: Ice & Water Final Pool: _Footings _Air/Gas Tests Final Framing Drain Tile Fireplace: _Rough In _Air Test _Final Siding: _Stucco Lath _Stone Lath _Brick Insulation Windows Sheathing Retaining Wall: _ Footings _ Backfill _ Final Sheetrock Radon Control Fire Walls Erosion Control Braced Walls Other: Reviewed By: , Building Inspector RESIDENTIAL FEES Base Fee Surcharge Plan Review MCES SAC City SAC Utility Connection Charge S&W Permit & Surcharge Treatment Plant Copies TOTAL i1614 9v4# 1.31.1io Page 2 of 3 ANY 17641 Sial TX, THE 2407rN'<F.SOTA STATE BUILDING CO tfGC Appendix E, Worksheet E-1 Resident,al Combustion kr Ca' sicn'-ic,n „' if r Furnace, Bol?er. rd c 'dater h ai :r in the Sarre Spaco) Sep 1 Complete vented combustion appliance informaion. FumaceiBollec Fan Assisted Direct Vent Input. Btuthr _ Draft Hood _ (Not tan assisted) & Power Vent Water Heater: Hood Fan Assisted /� Direct >,t ��'�iG tnput: Btuthr _'Draft _ (Nat fan assisted) & Power Ven; Calculate the volume of the Combustion Afp tce Space (GAS) cantau' ng comtxlstion appliances, includes to by code rmpliant o CAS volume: Eta The CAS all spaces contracted one another Determine Air Changes per Hour (ACH)' Default ACH values have been incorporated into Table E-1 for use with Method 4b (KAIR Method). If the year of construction or ACH is not known, use method 4a (Sfardard Method). .W.41 Determine Required Volume for CombustionAir 4a. Standard Method Total Btu'hr input of alt combustion appliances (D0 NOLCOUNT DIRECT VENTAPPj.jANCE.) input: Btuthr Standard Method in Table E -t to find Total Required Volume (TRV) TRV: ft3 Use column If CAS Volume (from Step 2) is greater than TRV then no outdoor openings are needed. If CAS Volume (from Step 2) is less than TRV then go to STEP 5. 4b. Known Air Infiltration Rate (IKAIR) Method Total BIu'hr input of all fan -assisted and power vent apiances NOT COUNT DIRECT VENT APPLIANCES) input: Btunr (DO Use Fan -Assisted Appliances column in Table E-1 to find Volume RVFA: ft3 Required Fan Assisted (RVFA) Total But hr input of all non -fan -assisted appliarvyes Input: Btu'hr Use Non -Fan -Assisted Appliances column in Table E-1 to find Required Volume Non (RVNFA) RVNFA: ft' -Fan -Assisted Total Required Volume (TRV) = RVFA : RVNFA TRV : } = ft3 If CAS Volume Pam Step 2) is greater than TRV then . utd openings are needed. If CAS Volume (from Step 2) is less than TRV then go to STEP 5, Ste}, L Calculate the ratio of available interior volume to the total required volume. Ratio = CAS Volume (from Step 2) divided by TRV (from Step 4a or Step 4b) Ratio = ! _ e Calculate Reduclon Factor (RF). RF = 1 Ratio RF = 1 - minus Calculate single outdoor opening as sf all combustion air is from outside. Total Blulhr input of all Combustion Appliances in the same CAS (EXCEPT DIRECT VENT) input Blu'hr Combustion Air Opening Area (CAOA) Total Btuhr divided by 3000 Btuthr per CAOA =, i 3000 Btuthr per in =`in1 Calculate Minimum CAOA, Minimum CAOA = CAOA multiplied by RF Minimum CAOA = x = int Calculate Cornbustion Air Opening Diameter (CAOD) CAOD = 1,13 multiplied by the square root of Minimum CADDDA CAOD = 113 .inimum CADA = in ' If desir ACH C sA RAE calculation or blower d 382 "te, Fo'v p ures in Section 304. PERMIT City of Eagan Permit Type:Building Permit Number:EA172052 Date Issued:09/14/2021 Permit Category:ePermit Site Address: 1964 Safari Tr Lot:072 Block: 2 Addition: The Safari 3rd PID:10-75852-02-072 Use: Description: Sub Type:Reroof Work Type:Replace Description:Does not include skylight(s) Census Code:434 - Residential Additions, Alterations Zoning: Square Feet:0 Occupancy: Construction Type: Comments:Please print pictures of ice and water protection and leave on site. If water damage is encountered, please call (651) 675-5675 to schedule a site visit to verify the extent of the damage. Any repairs must be inspected prior to covering. The inspector will determine if an additional permit will be required to repair the water damage. Valuation: 5,000.00 Fee Summary:BL - Base Fee $5K $118.00 0801.4085 Surcharge - Based on Valuation $5K $2.50 9001.2195 $120.50 Total: I hereby acknowledge that I have read this application and state that the information is correct and agree to comply with all applicable State of Minnesota Statutes and City of Eagan Ordinances. Contractor:Owner:- Applicant - Michael & Kristin Larson 1964 Safari Trl Eagan MN 55121 All Craftsmen Exteriors Llc 1020 East 146th St Ste 226 Burnsville MN 55337 (952) 898-4680 Applicant/Permitee: Signature Issued By: Signature