Loading...
896 Sunwood Ct CITY OF EAGAN ~Q 1698' • . 3830 Pilot Knob Road, P.O. Box 21-199, Eagan, MN 55121 PH ON E: 454-8100 BUILDING PERMIT Receipt # To be used for Sp DWG/G" Est. Value $99,000 Date AUG 28 ,1989 Site Address 896 Sl![iW00D CT 2 Block 1 Sec/Sub. SUNRFSE HII.LS 2 OFFICE USE ONLY Lot Parcel No. occupancy R-3 ~'¢-1 FEES zoning R" i ¢ Name JOS$PH Ij !}ILLER CONSTRUCTl ON (,4ctual) Const V~N aldg. Permit f~36.1~0 o Address 1$133 CSDAR AVE S {Allowable) y"N Surcharge 4g•~ Cit F~IN~N Phone 431-2001 # or scories y Lenglh -We Plan Review 318.00 1 Zo Name SAME oeprn - sac, ciiy 100•00 OU ¢ Address S.F. Total - SAC, MCWCC S7S.00 City PhOn@ S.F. Foolprints - F On Site Sewage _ ~Nater Conn ~Q' ~ W W Name On Site Well Waler Meter 90.00 Address Mwcc system ~ 30.00 5City Water Acct. Oeposit W City Phone - PRV Required _ S1W Permit 20' ~ I hereby acknowlege that I have read this application and state that the Boosler Pump - SIW Surcharge 1.00 inlormation is correct and agree to comply with all applicable State ol 228•~ Minnesota Statutes and City of Eagan Ordinan Treatment PI Signature ot Permitee APPROVALS Road Unit 340• 00 A Building Permit is issued to: JO E HI I.I.BR C0NST Planner - Park Ded. on the express condition that all work shall be done in accordance with ail Co+ncil appiicable State of Minnesota Statutes and City o( Eagan Ordinances. Bldg. 011. _ CopieS Variance - ToTAL 2.967.50 BuikJing Official Permit No. Permit Holder Date Telephone # WQTER G-' SEWER PLUMBING C ~D ' ~ ~ S/ H.V.A.C. EIECTRIC Inspection Date Insp. Comments Footings 1 9!l .3 ezie Foundation c Framing C ~ pST' G n,aG_ - Roofing Rough Plbg. Rough Htg. Isul. ~ Fireplace ~ Final Ht9. ~ Jr 0 ~ %'r T1 r Final Plbg. /7•,~,.-- i~ ~r ~ • ~.~,7J~ i~, ~ i`. -•r ~y~C:_ a c Const. Meter Plbg. Inspector - Notify Piumber Engr.IPlan Bldg. Final ~r S Deck Ftg. Deck Fnal weu Pr. Disp. ti' a', (Errtifiratt uf COrr~parrr~ titp of (eagan Drpttrtmm# n# lWd'mg J.prrtimt This Gerticate issuedpursuant to 1he requirements of Sectton 306 o}the U?riform Buitding Code certifying that at the time af issuance this structure was in campliance with the various ordinances of the City regulating beeilding cairstructian or use. For the fallowing.• u,cimiscation S F D GI G/ G A R Bldg. Pernift No. 16987 pccnpspcy Typc RA/M I Znning Divvia Ri Typc Const VN oWna oreu;iaing JOSEPH KMUR W467. Add,. 18133 CFlIAR AVE. S., FARMUDCN ' s„ila' naerar 896 SUNWOCD 00[lRT L-fity L.2, B1, SEMSE HII.iS 2DID ' 77 Da,e: NDVIIM 2. 1989 awaaing oW,; POST IN A GONSPICUOVS PLACE . . . - • . ~ . ~ ~ PERMIT.# MECHANICAL PERMIT AECEIPT # CITY OF EAGAN ' 3830 PILOT KNOB ROAD, EAGAN, MN 55122 DATE: CONTRACT PRICE: PHONE: 454-8100 i For Office Use Only: Site A ress BLDG. TYPE WORK DESCRIPTION Lot ~ Block Sec/Sub Res V, NeW ? m Name r~ ri'r Mult. Add-on Address ~ ~ • Comm. Repair ~ P. Other ~ c;ry F~]rmiro-l~r~ Phone a Name e i.° ' FEES ~ RES. HVAC 0-100 M BTU -$24.00 c Addr 8 L!I" Gn G ADDITIONAL 50 M BTU - 6.00 p City 7 4n Phone ~ I (RES. HVAC INCLUDES A/C ON NEW 1+ CONSTRUCTION) . . GAS OUTLETS (MINIMUM - 1 PER PERMIT) - 1.50 EA TYPE OF WORK ~ COMM/IND FEE - 1% OF CONTRACT FEE Forced Air l.Qs,Mn BTU , APT. BLDGS. - COMM. RATE APPLIES TOWNHOUSE & CONDOS - RES. RATE APPLIES Boiler M BTU MINIMUM RESIDENTIAL FEE - ALL ADD-ON & Unit Heater M BTU REMODELS - 12.00 Air Cond. 3 TON M BTU MINIMUM COMMERCIAL FEE - 20.00 STATE SURCHARGE PER PERMIT - .50 Vent CFM (ADD $.50 S/C IF PERMIT PRICE GOES Gas Piping Outlets # 4~ ~ BEYOND $1,000) Other FEE: 33-co S/C: Eo SIGNATURE OF PERMITTEE ' TOTAL• 'S0 FOR: CITY OF EAGAN PERMIT # ~ PLUMBING PERMIT CITY OF fAGAN RECEIPT # 3830 PILOT KNOB ROAD, EAGAN, MN 55122 DATE: CONTRACT PRICE HONE: 454-8100 " Site Addre,ss , BLOG. TYPE WORK DESCRiPT10N lot 1< Block -Sec/Sub ' es. v New Mult. Add-on m Name Comm. Repair ~ Addre~s ~ Other c City 'Phone RES. PLBG. ONLY - COMPLETE THE FOLLOWIMG: N . FIXTURES TOTA#? Water Closet - $3.00 S Nam 3 8 ~=c~ r~...• v Bath Tubs -$3.00 Add ~ Lavatory - $3.00 p Ciry"ISS` Phone"`,'` / av° 4Shower -$3.00 Kitchen Sink - $3.00 FEES Urinal/Bidet - S3.00 COMM/IND FEE - 196 OF CONTRACT FEE -~Laundry Tray -$3.OQ APT. BLDGS - COMM RATE APPUES ~Floor Drains -$1.50 TOWNHOUSE 8 CONdO - RES. RATE APPLIES Water Heater -$t.50 MINIMUM - RESIDENTIAL FEE - $12.00 --7-Whirlpool - $3.00 j MINIMUM - COMM/IND FEE - $20.00 -/-Gas Piping Outlets - $1.50 STATE SURCHARGE PER PERMIT - .50 (MINIMUM - 1 PER PERMIT) (ADD a.50 S/C IF PERMIT PRICE GUES SoRener -$5.00 BEYOND $1,000.00) Well - $10.00 Private Disp. - $10.00 Rough Openings - $1.50 ~ a SIGNATURE OF PERMITTEE FEE STATE S/C: FOR CITY OF EAGAN GRAND TOTAL: - T1~TC~PECTIN ~'~O~ I Control No. 11\*7 vl ~ ~ CITY OF EAGAN PERMIT TYPE: Ati I 1 132MN ' 3830 Pilot Knob Road Permit Number: 001619 Eagan, Minnesota 55123 Date Issued: 10113142 (612) 681-4675 SITE ADDRESS: Etil, . HLvCK,I APPLICANT: 1340 suMUaQa cr ~ aOETZ cQNSt rHnNAS !3i l LS 200 (612) 852-9269 P E R V L~ S TY q 1 i, rP TYPE OF WORK: T ; rr~i~ ntrr RArYON FRAM! NA VTNAI ~F+r~ -~'~)'bt _•.C~' L' ~ f.' i~~~]~~ ~~•?~~~'~~j~~G-J . - - . K~T y :it ~ ~ - ~ ` ~ ~k ~i i.. : ~ ~ ~ ~ _ . _ : • r _ ~ *t i p~ I 'f"+'A~'~' r.~ ~ ~'3- _ _ ~ -::e-.y~ • } . . :JS`~ ~ ' ? i _ :~i- ~ S ~ t !S a' ~+r? -r~ ~~~1 1 ti~L~ .f ~ ~..~.~:sr ~~l'~ T'::~ .i.-.-~ . . . . . .~-.i - F4nn11 No. Permk Heldar Dab TeNphons # SNV PLUMBINC3 , HVAC ELECTRlC a`' ELECTRIC Inapactlon Daq Insp. " Commenta Footings I Foundetion Framinp Roolinp Rough Plbg. Rou9h Ht9• Istd. Freplace Fktal Ft~. OrsatT9et Finei PIb9• Plbg. Inspectw - NotMy Plum6er Conat. Meter F.ngrJPlan Bldg. Firmf Ueek Ftg. Oedt Finai Well Pr. Disp. SEWEA dc WATER PERMIT ~-.~,1.. OFFICE USE ONLY CITY OPEAGAN MEfER #*~If 70~ PERMIT DATE 8/30/89 3830 Pilot Knob Rd. Eagan, MN 55122-1897 CHIP # 9Q 9/zo PERMIT # 10835 METER SIZE oC' B.P. RECEIPT # 3630 6/zgtug DATE ISSUE DATE ~'?'r~ B.P. RECEIPT DATE _ PRV - BOOSTER PUMP ITE ADDRESS PERMIT REQUESTED LOT Z BLOCK SEC/SUB 4 ~ ! ~ . ~ - • ~ ~SEWER ATER _ TAPS ' i' . r _ APPLICANT: _ ADDRESS: i COMM/IND RESIDEfJTIAL CtTY, STATE ~ J~ P -45- .2- NEW _ EXISTING PHONE:~rn / ZT~J ~ Lawn Sprinkler Meters are to be Installed PLUMBER: Ahead of Domestic Meters on Water Line. ADDRESS: Credit WILL NOT be given for Deduct Meters. CITY, STATE ' - ZIP PHONE: I AGREE TO COMPLY WITH CITY OF OWNER: EAGAN ORDiNANCE ADDRESS: ~ CITY, STATE ZIP PHONE: SIGNATURE HEN METER ISSUED PLEASE ALLOW TWO WORKING DAYS FOR PROCESSING. CALL 0545220 FOR INSPECTIONS. FQR STOR SEWER PERMRS, CONTACT ENGINEEAINO DEPT. I 0_ . . . _ . , ~ = , SEWM & WATER PERMIT OFFICE USE ONLY CITY OP EAGAN METER # PERMIT DATE b/ 'W 'U 3830 Pibt Knob Rd. 10835 Eagan, MN 55122-1897 CHIP # PERMIT # , METER SIZE B.P. RECEIPT # DATE ISSUE DATE B.P. RECEIPT DATE - PRV - BOOSTER PUMP SITE AqDRESS PERMIT REGIUESTED LOT BLOCK ~ SEC/SU6Q4- 1 - ` xSEWER Y- WATER - TAPS APPUCANT:'-~~ j • ADDR~SS: ' ` = - ' ' ' - COMM/IND - RESIDENTIAL CIN, STATE. ZIP'- NEW EXISTING ~ ~ - PHOIVI!: ~ = ~T~ I Lawn Sprinkler Meters are to be Installed C<. f r/__6 .t:7. t LL.r, t ~-l sc_1 PLUMBER: Ahead of Domestic Meters on Water Line. ADDRESS: , Credit WILL NOT be given for Deduct Meters. , CITY, STATE ZIP=~-`? ' ~ J • PHONE:' / I AGREE TO COMPLY WITN CITY OF OWNER: EAGAN ORDINANCES ADDRESS: CITY, STATE ZIP PHONE: SIGNATURE WFIEN METER ISSUED PLEASE ALLOW TWO WORKING DAYS FOR PROCESSING. CALL 454-5220 FOR INSPECTIONS. FOR STORIIA SEWER PERMITS, CONTACT ENGINEERINC,s DEPT. CITY OF EAGAN NO 16987 3830 Pilot Knob Road, P.O. Box 27-199, Eagan, MN 55121 • PHONE:454-8100 (1 ~0 BUILDING PERMIT Receipt a 15(0 To be used for SF DWG/GAR Est. Value $99. 000 Date AUG 28 , 1989 Site Address 896 SlTNW00D CT Lot Z Block 1 Sec/Sub. SUNRISE HILLS 2 OFFICE USE ONLY Parcel No. occupancy R-3 M=1 FEES Zoning R=1 W Name SOSEPH M MILLER CONSTRUCTION (Aclual) Cons[ V-N Btdg. Permit 636.00 o Addr2ss 18133 GEDAR AVE S (Allowable) V=N 49.50 pjtFARMINGTON phone 431-2001 x of Stories Surcnarge y Length 56' Plan Review 318.00 ~ Name SAME Oapth 5O ~ sac, ary 100.00 3 804 Address S.F.TOtal - SAC,MCWCC 575.00 m City Phone S.F. Footprims - On Site Sewage _ Water Conn 580.00 ~w Name OnSiteWell WaterMeler 90.00 ~i Addr05S MWCC Syslem xx aw Ciry Phone cirywacer 7~3~ ~cl Deposit 30.00 20. PRV Required - S/W Permit I hereby acknowlege ihat I have read this application and state ihat 1he Boosler Pump - SiW Surcharge 1.00 inlormation is corracl and agree to compiy wi all applica6le State of . Minnesota Statutes and Ciry of EaAan Treatment PI 228 • 00 /P6 OG Siqnature ol Permitee APPROYALS Road Unit 340. 00 A 6uilding Permil is issued to: .TOSEPH M MILLER CONST Planner - Park Dad. on Ihe express condition tfiaf all urork shall be done in accordance wrth aA Council applica6le State of Minnes~o,ta S~ L\ la[Nes and City of Eaqan Ordinances. gla9, pff, Copies Building Official L~Nd._Q-1A- I A Variance - TOTAL 2,967.50 5~957,~ / ~ Request 0 e / Flre Na. Roughtin Inspeclion Fequiretl4 ? Ready Now WII NaHfy Inspeclm 9-29-89 s ?NO wnaoaeaey? ~ I licensed contractor ? owner hereby request inspection of above electrical work at: Jab Adtlress (Streaq Bwc or Roule NoJ City 896 Sunwood Court ENK Ea an Seclion No. I Township Name or No. Rarge No. Couny Dakota Occupant(PRINn Phone M. Joe Miller Construction Co. 431-2001 Power Supplier pddress Dakota E1 ctr' Farmin ton MN 55024 Electrical Comrac[or (COmparty Name) ` Conbacbr§ Licenee No. Midland Electric Inc. 041610 Mail'vg ACdress (COn4aclor or Ownar Making Insleila4on) 14055 Grand Ave So, Suite E, Burnsville, MN 55337 AW (COntraclor/Owrier Makin W' n) Phone Number 892-6688 MINNESOTA STATE BOARO OF ELECTiiICRY , THIS INSPECTION ftEQUEST WILL NOT OrlggsMitlvrey BNp. - Haam 3-173 BE ACCEPTED BY THE STATE BOARD 1821 Univerelry Ave., SL Paul, MN 55101 UNLESS PROPEF INSPECTION FEE IS Phone(61P) 842411100 ENCLOSEO. REQUEST FOR ELECTRICAL INSPECTION .r' ee-oooo -o~ ? See instruCions tor completing Uis formyon back dryellow copy. 5.4957 X' Below Work Covered by This Request Add e;s.';jTypeofBuilding AppliancesWired EquipmentWired Home Range Temporary Service Duplex Water Heater Electric Heating Apt. Building Dryer Other (Specify) Comm./IndusVial Furnace Farm Air Cohdkioner 01her[specity) CoMractor§Remarks: Compute lnspection Fee Below: # Other Fee # ServiceEnirance5ize Fee # Circuits/Feeders Fee Swimming Pool 0 to 200 Amps 0 to 100 Amps Transformers A6ove 200 - amps e 700 _ Amps SIgnS Inspacror5 U5e Onty: DO TOTAL Irrigalion Booms Special Inspection Alarm/Communica4on Other Fee ( I, the Electrical Inspector, hereby Rough-in certity that the above inspection has Flnal ea ~ been made. rO G OFFICE I/SE ONLY This requast void 18 monMS irom 451 y2 v Fequest Dele Fire No. Foug~-in Inspec~i0n ` Re iretl? ea0y N. f7 Wil1 Notiry Inspedar Ves ~ No When FeatlY? licensed contractor p owner hereby request inspection ot above electrical work aC Job Atltlress IStreet Brn or Poute No,) Ciry " G N~~ ~cwrzc ~~.I Section No. Township Name w No. qaige W. Caunty~A^ IL OccupantlPRINT) 00 ~J ~ Phone No. "Ill-l.*"SLG~_ . Power Supplier AEtlress Co ElecMcal 'GonVector lCOmpany Namel A nirador§ License No. 1 Vl Mailing Atltlress IConVactor or Owner Making Mstallation) v Aullqrize0 SignaW trac~o Owner Making Inslallation) PFrone Number MINNESOTA STATE BOARU OF ELECTPICITV 1HIS INSPECTION REQUEST WILL NOT Grigge-MlEwsy BWy. - Room S173 BE ACCEPTED BY THE STATE 90ARD 1821 Unlvnsity Are., SI. Vaul. MN 55101 UNLES$ PROPER INSPECTION FEE IS Phone(6fY)662-0800 ENCIOSED. REQUEST FOR ELECTRICAL INSPECTION A°'~9 EB-p00pLOB K 4 513 2 $ee insfruc~ions lor completing this form on beck oi yellow copy, ;~o a~33 9 ~il" Below Work Covered by This Request ew Adtl Rep. TypeofBuilding AppliancasWired EquipmenlWired y,( Home Range Temporary Service Duplex Water Heater Electnc Heating Apt. Building Dryer Other-(Specify) Comm./Industnal Fumace Farm Air Conditioner Otner (specity) Comraaor's Remarks'. Compute Inspection Fee Be/ow: # Other Fee # ServiceEnirenceSize Fee # Circuits/Feeders Fee Swimming Pool 0 to 200 Amps 0 to t00 Amps Translormers Above 200 _ Amps Above 100 _ Amps Si9ns mspeaor's use oniy: Irrigation Booms 3 00 .5 ~ Special InSpection TOT Alarm/Communication THIS INSTALLATION MAY BE ORDEREO DISCONNECTED IF NOT Other Fee COMPLETED WITHIN 18 MONTHS. I, the Electrical Inspector, hereby Rough-in D818 p~,~G l certify that the above inspection has F;nai oa been made. ~r V OfFlCE USE ONLY This request vaitl 1B mOnths irom \ c^~ ~ vr ~ ' DATE: $/30/89 419$ COUNTRYSIDE DR1VE, i.3, B2. COUNTRY HOL[AW RE* 896 SUNk'OOD COURT. L2. Bl. SUNRISE N1GI.S 2nd XXplYOUr Sewer & Water Permit for the above property has been completed. It will be held at the 1 Public Works Garage (3501 Coachman Road) until ihe meter is picked up. BE SURE TO CALL PUBLIC WORKS (454-5220) FOR YOUR PERMANENT WATER TURN ON. Your Sewer & Water Permit for the above property cannot be completed for the following 'reasons: b - Your'Sewer & Water Permit for the above property has been completed, 6ut the meter cannot be issued or o~upancy allowed until further notiee. - COMMERCIAL, ROJECTS ONLY: Please pay for meter at City Hall. Meter size must be confirmed by Bill Adams or Dirk House (Plumbing Inspectors - 454-8100) before issuance. WARNING: BEFORE DIGGING, CALL LOCAL UTILITIES - TELEPHONE, ELECTRIC, GAS, ETC. - REQUIRED BY LAW. CONTACT COMMUNITY DEVELOPMENT DEPARTMENT FOR WATER TURN ON POLICY. Secretary, Building Inspections Dept. ~ Cl'14~ PLUMBING(RESIDENTIAL) ~ PermitApplication City Of Eagan 3830 Pilot Knob Road, Eagan Mn 55122 Telephone # E51-675-5675 FA.R # 651-675-5694 Please complete for: Single Family Dwellings Townhomes and Condos when permits are required for each unit Date l.!! Site Address ~i )nuocd C-L Unit # Property Owner I`-L-- cab nm cL'&~ Telephone #~,ny~ ~a Contractor W_P pIpEWORKS 3870 DODD ROAD Address cAGAN, MN 55123 CitY State (1151)365 1340 Zip Telep6one # ( ) The Applicant is Owner Contractor Other Septic System New _ Refurbished Suhmit 2 sets of plans and MPC license $ 100.00 Inciudes Counly fee. Additlonal consultant fees may apply. Alterations To Esisting Dwelling Unit, Including $ 50.00 _ Adding fixtures to lower levels or room additions, excluding water softener and water heater _ Abandonment of septic system _ Water tumaround 5/8" meter if needed -$121.00) Other: _ RPZ _ new installation _ repair _ rebuild $ 30.00 _ Lawn irrigation system _ Water sottener 1z'Water 6eater $ 15.00 Zeplacement _ additlonal State Surcharge $ .50 Total $ ? I hereby apply for a Residential Plumbing Pemut and aclmowledge that the information is complete and accurate; that the work will be in conformance with the ordinances and codes of the City of Eagan and with the Plumbing Codes; that I understand this is not a pernrit, but only an application for a permit, and work is not to start without a permit; that the work will be in accordance with the approved plan in the case of work which requires a review and approval of plans. ApplicanY Prited D anie App icl a t~s3i atur ~ ~ 2004 RESIDENTIAL BUII,DII~G PERMIT APPLICATION Czty OfEagan 3830 Pilot Knob Road, Eagah MN 55122 _.._Telephone# 651-675-5675----FAX#-651-675 5694---.----------- New Construction Re~+ui2ments 3 registered site surveys showing sq, ft, of bt, sq. it of house; aodall roofed areas RemodeVReoairReouiremenis (20% mapmum lof coverqge allowed) Zcopies of plan ' . 2 copies of plan showing 6eam & window sizes; poured found desi9n, eta 1 set of Epeyy Calculations for heated additions 1 set of Energy Calculations 1 site survey foP additions & decks 3 copies of T~ee Preservafion Plan if lot platted after 7A/93 Addfion-indicafe ifon-sife septic sysfem Rim Joist De}ail Options selecfion sheet (bldgs witlt 3 or less un'rfs . Date Construction Cost L9 ~°S~j~ ~ Site Address Unit/Sfe # Description of Work Multi-Family Bldg _ y~ n* Fireplace(s) _ 0 _ 1 2 Property Owner ~ Telephone # 0~5l A/ • ~ lc) 'Renewal By Andersen Contracwr _ 1920 County Rd. "C" West Address Roseville, MN 55113 state 651-264-4777 C`~ License#20130983 ' Telephone#( ) COMPLETE THIS AREA ONlY IF CONSTRUCTING A NEW BURDING Energy Code Category M~nesota Rules 7670 Cate orv 1 Minnesota Rules 7672 (dsubmission lype) - Residenfial Ventilation Category 1 Worksheet . New Energy Code Worksheet . Submitted - SubmitEed • Energy Envelope Calculations Submitted Have you previously constructed n building in Eagan with p similar plan? Y_ N if so, 25% plan review fee applies. - Licensed Plumber ~ u~ Telephone # ( Mechanical Confractor Telephone 1 3 Sewer/Water Contractor Telephone Y I hereby apply, for a Residential Building Pernut and aclmowledge that the information is complete and accurate; that the work will be in conformance with the ordiuauces and codes of the City of Eagan and the State of MN Statutes; I understand this is not a pemiit, but only an application for a perinit, and work is not to start without a permit; that the work will be in accordance with the approved p in the case of work which requires a review and approval ofplans. 4~ Apphcant's Pnnted Name ~ App cant's Signature ~ MiFZr.E usE oivr,Y Sub Types Ot -Foundation-----0-07-05=plez---l3i- 13-16=pfex °b.--`20--Pool--- L7- 30--Accessory Bld _ 9_ ? 02 SF Dwelling ? 08 06-plex ? 16 Fireplace ? 21 Porch (3-sea.) ? 31 Ext. AIt - MWti q - 0301 of_plex,0 09 07-plex 017 Garage ?22 Porcfi/Addn. (4-sea.) 33 Ezt.AIt - SF ?04: 02-plex ? 10 08-plex ? 18 Deck ? 23 Porch (screen/gazeho) ? 36 Multi Misc. ? 05` 03-plex ? 11 10-plex ? 19 Lower Level ? 24 Storm Damage ? 06 04-plex ? 12 12-plex' Pibg_Yor_N ? 25 Miscellaneous Work Types ? 31.New ? 35 Int Improvement ? 38 Demolish Interior ? 44 Siding ? 32 Addition ? 36 Move Building [1 42 Demolish Foundation ? 45 Fire Repair ? 33.Alteration ? 37 Demolish Building" ? 43 Reroof ? 46 Windows(Doors ? 34 Replacement ' •Demolltion (Entire Bldg) - Give PCA handout to applicant Valuation Occupancy MCES System Census Code Zoning City Water , SAC Units Sfories Booster Pump . # of Units Sq. Ft. PRV # of Bldgs Length Fire Sprinklered Type of Const Width REQUIItED INSPECTIONS _ Footings (new bldg) _ FinaUC.O. _ Footings (deck) _ FinaVNo C.O. _ Footings (addition), Plumbmg _ Foundation . IIVAC-.' Drain Tile Other Roof Ice & Water Final _ Pool. Ftgs Air/Gas Tests Fina1 _ Frazriing _ Sidmg _ Stucco Stone _ Bnck Fireplace _ R.I. ° Air'Test Final Windows Insulation _ RBfaiiung 4Va11" Approved By: , Building Inspectar - Base Fee Surcharge Plan Review MC/ES SAC City SAC Utility Connection Charge , - S&W Permit & Surcharge Treatment Plant Llcense Search Copies Other Total ""•~•,d~••~ iuu R6.JV rna ~oa o/1 -q4ty0 tC~LYL`tTAL dSk'@CtUtit47ff[Y . _ . ~ : - " • ~81Up 3une'7, 2A07 - • . CY Of Eagan 3836 Rilof S.ttob Rogd F-ft$M MN 55122 . To VGhom A May Crntoern: IIder 7ones is authorized tA pt~ baildlag Iermits €orRennwal by Aadersei- piexse aIIow Eider Iones to prm•ido tfiis servicc for ns in Hagan. It;a enthotizaticin is vaiid for any date bcyond 06101: untit a~'onawa! bY Andersan munager upms1Y revokes ft in wiiBng tA tha City I rcquest tfiis sutfzodzation be accTted.axpedi@ously, as to aot deIay in rhe processsi%tg of auc baildinS Pcanits baY furt$cz. Picasc caII mc I£thcro acn en coRtacted at 7b3-SO?,1t7p6_ Y 9am[ons.. I can Ua ° _ r. Your immqdiate xttcnt3ott to this msttcr i.y ate& ` - SinceialY> _ . ' . yviond R Rau ostallation Ma~nagor . Rettowai by Andascn CorPorafivtz . . rc.: Kmn_F.icte.r Snncc VoL~ . G - '7 -sc~j ~,H Received 7ime Jun. 1. 1~01P}d • RESIDENTIAL BUILDING PERMIT APPLICATION CITY OF EAGAN 3830 PILOT KNOB RD, EAGAN MN 55122 651-687-4675 NawConstructionReaulrements RemodellReoairReauirements l ~ -7. 4,5 • 3 regislered site surveys shmving sq. ft, of lot, sq. ft. of house; and all mofed areas • 2 copies of plan (20% maximum lot coverage allowed) . t set of Eneigy Calculations for healed additions • 2 copies of plan showirg 6eam 8 windovr s¢es; poured fouiW desgn, eic.) . t site survey tor exterior additiorks & decks • 1 sel of Energy Calculatbns . IMipte rf home served by septic system (or additions • 3 wpiw of Tree Preservation Plan'rf lo[ platted aRer 711/93 • Rim Joisl DeNail Optlons selectlon sheel (bldgs with 3 or less un'rtS) DATE VALUATION t l G31J !P, ~ 4A(,cDOaCl CT, MULTI-FAMILYBLDG _Y ~1V SITEIApD~Dy~6FWRES cJ TYPE rG-(-00*- 3%qs _ FIREPLACE(S) _ 0_ 1_ 2 APPLICANTAr'o";Ca'l ~46yz7~Ycl~d!S STREETADDRESS Idd 417 AI/CDI CITY G"n6Ji~It- STATEA/1) ZIPSS3,3 - ; TELEPHONE # I~a ~ID7~~l~ CELL PHONE # FAX # PROPERTYOWNER ~e- C-Yo`rn'~4,-1 TELEPHONE# (OSI - ~ri 8rI -021cJ COMPLETE THIS SECTION FOR "NEW" RESIDENTIAL BUILDINGS ONLY Energy Code Category _ MINNESOTA RULES 7670 CATEGORY 1 MINNESOTA RULES 7672 (d submission lype) • Residential Ventllation Category 1 Worksheet Submitted • Ne . ~ I ed . Energy Envelope Calculations Submitted D _ D JUL 1 7 200Z Plumbing Conhactor: Phone # _ _ Plumbing system includes: Water SofCener _ Lawn Sprinkler BY P'ee: $90.00 _ Water Healer _ No. of R.I. 13alhs No. of Baths Mechanlcal Contractor: Phone # Vlechanical systcm includes: Air Conditioning Pee: $70.00 Hcat Recovery Syslem Sewer/Water Contractor: Phone # I hereby acknowledge ihat I have read this application, state that the information is correct, and agree to comply with all applicable State of Minnesota Statutes and City of Eagan rdinancesk ^ ~ Signature of Applicant OFFICE USE ONLY Certificates of Survey Received _ Tree Preservation Plan Received _ Not Required _ Updated 4102 OFFICE USE ONLY = • O 01 Foundation ? 07 OSplex ? 13 16-plex ? 20 Pool ? 30 Accessory Bidg ? 02 SF Dwelling ? 08 06-plex ? 16 Fireplace ? 21 Porch (3-sea.) ? 31 Ext. Alt- Multi ? 03 01 of _ plex O 09 07-plex ? 17 Garage ? 22 Porch/Addn. (4-sea.) ? 33 6ct. Alt - SF ? 04 02-plex ? 10 08-plex ? 18 Deck ? 23 Porch (screened) ? 36 Multi ? OS 03-plex ? 11 10.plex ? 19 Lower Level 0 24 Storm Damage ? 06 04-plex ? 12 12-plex Plbg_Y or _ N ? 25 Miscellaneous O 31 New ? 35 Int Improvement ? 38 Demolish (Interior) ? 44 Siding ? 32 Addition ? 36 Move Bldg. ? 42 Demolish (Foundation) ? 45 Fire Repair ? 33 Alteration ? 37 Demolish (Bldg)• ? 43 Reroof ? 46 Windows/Doors ? 34 Replacement "Demoiition (Entire Bldg only) - Give PCA handout to applicant Valuation Occupancy MC/ES System Census Code Zoning City Water SAC Units Stories Booster Pump Nbr. of Units Sq. Ft. PRV Nbr. of Bldgs Length Fire Sprinklered Type of Const Width REQUIRED INSPECTIONS _ Footings (new bldg) FinaUC.O. _ Footings(deck) FinaUNo C.O. _ Footings (addition) _ Plumbing _ Foundation HVAC _ Drain Tile Other Roof _ Ice & Water _ Final _ Pool _ Ftgs _ Air/Gas Tests Final _ FIanll°g _ Siding Stucco Stone _ Fueplace _ R.I. _ Air Test _ Final _ Windows (new/replacement) _ Insularion _ Retaining Wall Approved By , Building Inspector Fee Base Surcharge Plan Review MC/ES SAC City SAC Water Supply $ Storage SRW Permit & Surcharge Treatment Plant Plumbing Permit Mechanical Permit License Search Copies Other Total • 1989 HOILDIPG PERIiIT APPLICA2ION CITY OF 1 L9 Is ti SII7GLE FAMILY DiiELLffiGS !lJLTIPLE DWELLINGS COt4'lERCIAL 2 SETS OF PLlNS 2 SSTS 0F FLdN3 2 SETS OF IRCSTfECTURiL 3 HEGI3TEAED SITS HORVEYS BBGIST6RED SZtE 3II8YES3 - i S?80CTQAAL PLENS ;ET OF EbEAGY CiLCS. (CHEC% 1T17H BLDG DIY.) 1 SSf OF $PECIFIC9TION5 1 3Sf OF E6EBt3S CILCS. 1 8ET OF ENERf3T CALC3. l4ULTIPLE DWELLIN(iS AENTAL DNITS FOB SILE UBITS 1OF OBITS IOTEs WDR£SSES FOE CORNER LOT3 - COPTA?CPOA/HOMEOiiNEA !IDS! DLSIGSITE IiBICH IDDRESS IS DESIAED. 80 CH?NGES TiiILL BE ALLflWED OPCE SUILDIPG PEAHIT 13 I3SQED.- SEi1ER 6 iiATER PEAHIT FEES lAD ,CCOUNT DEP06IT l66S WII.L B8 INCLODED VIT6 THE 3IIILDINf1 PERMTT FEE. PROC£SSIHG iDO FOB SEWEA tAD IiATEfl PEAMIT3 I3 TWO DAYS 0lICE l PERMIT 6?3 BEEN COMPLEfED INDIC9TING A LICEPSfiD PLDMER. PENALTB APPLIFS WHENs PERMIT IS NOT PAID FOR IN SAME MONTA IT IS RE4IJESTED. LOT C6ANGE IS REQUESTED ONCE PERMZT IS ISSUED,., U 6 2 u lq89 ~ 06 fio Be Used For: Valuation: Date* U z Z-`~ ~ Site Address ~ C1lo &n~ &-e_ "J ~ Dco" OFFICE D5fi ONLI Lot ~ Block ! Oceupancy -R 3 M-I ~Fs 7onin6 R- I Pareel/Sub Coxaw~ V~N Bldg. Permit 36.oD ,:.i.c~abae _Surcharge eIG,So Otimer of atories ~ zan Aeviex 31 R, na Length t_ kC, City 17)D. Address Depth 50 "AC, MWCC ri C~.r S.F. Total -aater Conn 6,80k On City/Zip Code Footprint S.F. iiater Heter 9 o rr lect. Deposit ,oa Phone On aite aevage S/W Permit z-,.oo J On site xell 3/ii Surcharge 1.00 Contracto MWCC Syatem ~ Treatment Pl. ZLY, 00' p City vater ~ Road Unib 3 0 oa Addresa ~4_6 • PRV reqnired _ Yerk Ded. Hooster Pump _ Copies City/Zip Code~ 5 to Zq 311BTOTlL lPPA0YAL3 Penaltq Phone '7 3 / " 'Z-~ / Planner _ iOTAL Council ) . ~~TZ3~5 Arch./Engr. Bidg. Off Qariance Address City/Zip Code Yhone f ~ V,LI L(,t.qTlOfV . . . ` ' . , GAr~a ~c- ~ ~ ~ 2y x 24d = s7(, z X l2 ~ zy h~o x i~"% ~7vov m`~- ab~ sl = I 3Z~ /yx s_ '70 13~ ~ x/y ` _ • 1 ~~C 1 V - I O I Ll 0 (x5h= ~)C~~ou ~~84 ~1 ` . M32-2lR-239 / CERT/F/CATE OF S7A4Wr/ ' SuNWOOD ~ I~~~s / , 0I 25'~, tn cv F2 s~. o y. 585°40'4I'E ps239 ^ lb s~12Yltr, ~ ' , p \ 2')H 6L.9°~,4' ,o Z ~~32~` ZS,OO O ~ ~ 6 • ,k- P ez~4%" . „ vvr~ Q~~~,y \ ~°~+~~•A ~ \ 3 . . m •'t. ktiP~ 1 ~E EAGPV ERIAT DEPT ' ; . .,g Scale: 1" = 30' ~ D SCRIPTION / NEREBY CERT7fY TNAT TN/S SGPVFY, fR.AN' AR REPOVP/ Lot Z, B1oCk I, WAS PREPARED BY ME OR (/NGER MY O/RECT SYA°ERV/S/AM SUNRISnIILLS 2fl-AbDITION AHD TNATJ AAl A DULY R£G/STERED LANO SURVEYqR Dakota Coimty, MinneSOt& UNUER TNf LAMS Of THE STATf QF AI/NNESOTA. Plat bearings shown o Denotes iron monwnent OAT£ l qEG Aoa 8140 (,~xistiny, Pro ose brandt anginaaring P. iurvaying 2105 WOOdI tfajl ~ burnivllla, minnaiota S5331 (vIR) 43501966 A32-21 d -89 azTx og ~ ~ ; . . HUZLbINd bEPAri11•IE11T .-4, • ! 1 XXTEEtI012 ENYF.tOPD AYEfiAaE IIUII COIdPUTATIoN (a (To be subroitited nitih building permib applicatiion) one or Two Family Dwelling G Owner lI].1 oliter Bite llddrese _ t-.oT Z -1~Q.c-c1f I {4i 11c Z Contrdotor DaLe ~ ; Phone ' LIIIERL fEGm OF EXPO6Eb YlALL 4- M above grade I/ . TOTAL EXPOSED WALL AREA Qs FT+ oPAqUE WA1,L Cott5'TqUCTiUNI l'U'l Yalue x Areu 's oataii floll ,nqx sq. Fr. /87z1I: 1S (u)(A) re[erenoe Z~y-• . 0'71o x gR, FT. / Lo'3 =-M(A) : [rom -f 1 H~ pu-_' 04 v x Sq. F'T. ' . ~ ~U~ ~A~ at . tached x s@. FT. = p)(4) slieots x 8Q. FT. = (p) (A). . npn x Sq. FT. _ (U)(A)• 1I1NDDti931 "Ull Value x Ares • • Flalce & Type Ix S F'T? . 'z.~1175, IZo-4. (u) (A) u n npn x eq. FTi = (U)(A) Ux tiQ. M = ~U~ ~A) . x Sq. FT: ~ (U)(A) DoOltg! ".U" Yalus x Area , Flalte & T ' yra ~ 5 4- x sQ: Fm+ ~135 Iu)( e) ~~pu x SRi Fr. ~ (A) npu Q. . (U)(A) - - x Sg. FT. (U)(A) ToTAts ~EJ s@. E'T._ 0(1157, ZI (u) (A) TOTAL I~~(A) VALUEB AVERAUE Itpll 4 l~ ~i F. I n . DIVIDED BY TOTN, {7ALL A1tEA " AVENAaL ~~Ul~ ~ 5 leoe ior 1&2 family dryei nge KOOF'/OEILINa! / . ToTlu, AFtEA t Delail reierence IOull irom ~~~n x sQ. FT?3,~ (U) (A) uEtnched slleete. - tiull x 3Q, FT. ~ (U)(A) Dedetib9 oponiugo apn x ~Q• ° ~~)~A~ in roofs • npu XsR• FTc = (U)(A) . x 3Q~ M (U) (A) TOTAL (U)(A) VdLUEB DIVIllLD HY . "tOTAL AOOF/ClUa AllEA llab I AVEIiAqB ~~enbilttted roofe. . . , , . p'l l6~~= ,~E#~il, ~ I -:i~ ' iy I ~ 1.~ . !i M ~7,~ i ~ ~r ~ i . q 4 ~ i 'y ~,.PJ . ~ [ ti _ . ~ $~3 X( Zz;-ZZ-I- 4v-F4d) _ , : . . , ? ~ Y ' __~4..~, •I' . ~ h . . N~ ~ I . . i.. , _ ;/0~0, , . ~ ' ~ . . . . . . ..1... . ~ 1 1.L . , ~ ~ y . j . ~ . . . . . . _ . _ : _ . . , . _ . . .~~.:7 -e74-x~g _ : _ . I... __...?r Z4 X(o~ 6.2s i _Y~ . : , ~ ; y•~ , ~ a;=;s; ~ . _ ~ _ . ~eori, Ir.(L, ~v~ St,. 3?~5_, ~?~S -.~..~kld~ ~ ~r~ ~ .l.o IL'~~x1N~1 Wo"1 ~xPb~P 2bll~l8 IehM~_202d~. ~ _ Ob ~ ; . ~ _ . _ . ~ W~pu~ ~ i 75' ~ ...T , ` ~ , t 3la 5' r--~ : 7~ = g~,~ ; ~~s ~1 , , . ~~~/"X~ ~ i 4hl . ~ • ' `„'1' t _ /I I~ ~ . i : ~ +~,~Tt I`' . i ~..i. ~ " 1 y r..r^• . . . t I' -1~ . . t , ~ , ~ t '~i ~ ~s~_ ~ ~5 •:l h;~ ~ ~ . ~ : . •'"'WALIi SEC_ TIOB--' ~ Determining I+UII valuea at Roofi Wa11j Aim; bnd Conaa Blook ' . i ROOF/CEILIN(1 R VALU 14) Interior Air l'ilm 0461 . 2.) 5/8 " ayp, sd: 456 3: ) Insulation ¢4+vo 4.) Exterior Air Film 461 I 2 3 lBTILL) . 6 • ItuIl a 1/R= .,'LbTAL (R)a ~ 7,43 8 WALL R YALU q 6.) Interior Air Fills 0;68 7+1 1" aYP. Sd• ~45 86) Inaulation 19~00 • . , 9.) $~jL-r-P-4TE Z•p9- to:) Masonite siding a61 W 110 Exterior Air Film 617 l'U,t is ,/au . 043 ToTw (x)= 23.or ~Z RIM R YALUP 12,) Interior Air irilm , 0468 ' 14 j~,) Z°e Fir tRim Jo~st 11488 16.) Maeonite Biding 467 17:) Exterior Air Film . i17 0 ~ n , d • . . Itvit e 1/Ra >64D TOTAL (R)a ~+7•gT U . De • ~ FOUHDATION ~ R VALU 184) Interior Air Filot 0468 1g 190) 20: ) 12-r1 yTk1Pi~D 1l ~rx~ n d g°' ~ 21.) 12" Conorele B2ook 1t28 ' d . n 10 224) :234) Exterior Air Film ' 07 e l.j° nUu y 1/R= ,07(0 T9T1lL )3.1Zi . ~ ; . ~ 7U.1, TY OF EAGAN PERMIT C°"t ° 1171 PERMIT TYPE: 3830 Pilot Knob Road B U I L fJ .T. N G Eagan, Minnesota 55123 Permit Number: 001619 (612) 681-4675 Date Issued: 10 / 13 / 9 2 SITE ADDRESS: e9e suNwooo rr Lor: z BLOCK: 1 SUNRISE HILLS 2ND DESCRIPTION: --Buildihc~ Parmit 7ype BASEMENT FINISH ~Building-'Work Type RITERATION UBC Qccupancy- R-3 ~ i J ~.lil Jr.. , f . ..G. C REMARKS: a h ^ ; ,/I ~ ~ v FEE SUMMARY: Base Fee $35.00 COPY $.50 5urcharge , .50 Total Fee $36.00 5ubtotal $35.50 CONTRACTOR: - Applicant - S7. LI pyyNER: GOETZ CONST THOMAS 18519258 000347 1`HOMAS GOETZ CONST 9030 11TH AVE S 9030 11TH AVE S BLOOMTNGTON MN 55420 BLOOMfINGTON MN 55420 (612) 852-9258 (612)851-9258 I hereby acknowledge that I have read this application and sL'ate that the infiormation is correct and agree to comply with all applicable State of Mn. Statutes and City of Eagan Ordinances. L - APPLICANT/PERMITEE SIGNATURE ISSUED II)Y. S NA7UFi~- INSPECTION RECORD C°"tr°' 1171 CITY OF EAGAN PERMIT TYPE: B tJ z L D I N 3830 Pilot Knob Road Permit Number: 0 e 1 6:I. 9 Eagan, Minnesota 55123 Date Issued: 1 B/ 13 J 9 2 (612) 681-4675 SITE ADDRESS: Lo T: z B L 0 C K: 1 APPLICANT: $96 SUNW00D CT GQETZ CUNST THQMAS SUNRISE HILLS 2ND (612) 852-9258 PERMIT SUBTYPE: TYPE OF WORK: BASEMENT FINISH ALTERATION iNSPECTION . .A FRAMTNG FINAL ~ T ~ PEw~:"'*W cinr oF EAc,aN 1992 BUILDING PERMIT APPLICATION 681-4675 SINGtE & Mt1LTI-FAMIlY 2 se•;s of plans, 3 registered site surveys, 1 copy of energy calcs. COMMERCIAL 2 sets of architectural 8 structural plans, 1 set of specifications, 1 copy of energy calcs. Penalty applies when typing of permit is requested, but not picked up by last working day of month in which re uest is made lot chan e is re uested once ermit is issued. Date ln / g 1 2 Yaluation of work " 5ite Address: SsYG 54'--a'n c6vn7- - STREET . STE t Tenant Name: STf„f_ c~.azcsiC £ LOT BLOCK ~ SU6D. P.I.D. N / UxUv 1 L ; ,l,Qd Descri tion of work: The applicant is: ? Owner 19 Contractor ? Other (oeserine) Name s-cT~ ut- Phone L&c.- L3(x Property LAST FIRST Owner Address 9-1 r. c ~ . STREET STE / City State [+p .<6'1z3 Company Phone W-42sfr ContreCtar Address 403o S~. License EXp.3 )City State V~r wu. Zip SS~czo ~ Company Phone Architect/ Engineer Name Registration # Address ~ City State Zip ~ Sewer & water licensed plumber . Processing time for sewer & water permits is two days once area has been approved. I hereby acknow1edge that I have read this application and state that the informaiian is cnrrect and agree to comply with all applicable State of Flinneaota Statutes and City of Eagan Ordinances. Signature of Applicant: vrrwc u~~ vn~~ ~ BUILDING PERMIT TYPE ? 01 Foundation ? 05 Apt. Bldg *09 Basement Finish El 13 Public Fac. ? 02 SF Dwg. ? 06 Garage/Accessary O 10 Swim Poal O 14 Agffcultural ? 03 Two family ? 07 Fireplace ? 11 Res. Add./Porch ? 15 Miscellaneous ? 04 Multi-fam. T.H. ? 08 Deck ? 12 Comm./Ind. WORK TYPE 1~31 New ? 34 Repair ? 37 Demolish b 32 Addition ? 35 Tenant Finish ? 99 Undefined ? 33 Alterations ? 36 Move - 'aENERAL INFORMATION Const. (Actual) Basement sq. ft. MWCC System (AlYowable) lst F1. sq. ft. . City Water UBC Occupancy 2nd F1. sq, ft.. PR4 Required Zoning Sq. Ft. total Booster PumP f of Stories Footprint Sq. ft. _ fire Sprinkler Length On-site well Census Code ~ Depth On-site sewage SAC Code APPROVALS C"$"S I~J-1 ~ G~»+s., Planning Building Assessments Engineering Yariance REGIUIRED INSPECTIONS ? Site ? Footing ~Framing ? Insulation ? Mallboard ~Final rp Draintile ? Fireplace Permi t Fee ~ C. ny v.imc;m: s Surc-f+ar'-4e-- I'lari Review I ic ns 7 T City SAC Mater Conn. Water Meter Ace:t. Deposit S/W Permit 5/W Surcharge Treatment P1. Road Unit Park Ded. Trails Ded. Copies -3s Uther Total: SAC % SAC Units w 1999 BUILDING PERMIT APPLICATION (RESIDENTIAL) ciTY oF Enaax c r 3830 PILOT KNUB RD - 55122 ~ 0 C) (651) 681-4675 ~ New Construdion Reauirements RemodeVReuair Reauirements 3_ . 9 ? 3 registered site surreys ? 2 copies of plan ? 2 copies af plans (inGUde beam & window sizes; poured fnd. design; eta) ? 1 site surveys (exterior addkions & decks) ? t energy calculations ? 1 energy calwlations for heated additions ? 3 copies af tree preservation plan 'rf lot platted aRer 7/7l93 requiretl: _Yes _ No DATE: 3" I~) - 7 `Y CONSTRUCTION COST: ~C960+ DESCRIPTION OF WORK: ~~.nrlC.VaC7i/''V"7~t STREET ADDRESS: LOT: ~ BLOCK: SUBD./P.I.D. S LA Vs. nL~ CR 1`S 7e' Name: ko- ck^j pait' Phone#: PROPERTY [.est Firsc OWNER O ~ !~o G I Street Address: City &QZa- State: A,l VL Zip: Company: fotll" e" r1A-,, f~~~vt C- Phone ik: 73/- 3~ ~l c) CONTRACTOR Street Address: r~ 4nl214 r e avi(Q-_ License # 33 3t Exp. City J ~ a. k. ( S[ate: Vh P't Zip; ARCHITECT/ ENGINEER Company: Phone Name: Registration !t: Street Address: Ciry State: Zip: Sewer 8 water licensed plumber (new construcGon only): . Penalty applies when address change and lot change is requested once permit is issued. I hereby acknowledge that I have read this application, state that the information is corcect, and agree to comply with all applicable State of Minnesota Statutes and City of Eagan Ordinances. Signature of Applicant: V 14 G UFFICE USE ONLY Certificates of Survey Received _ Yes _ No Tree Preservation Plan Received _ Yes _ No _ Not Required OFFICE USE ONLY BUILDING PERMIT TYPE O 01 Foundation ? 06 Duplex 0 11 Apt./Lodging ? 16 Basement Finish ~02 SF Dwelling O 07 4-plex ? 12 Muiti RepaidRem. ? 17 Swim Pool 03 SF Addition ? 08 8-plex ? 13 Garage/Accessory ? 20 Public Facility ? 04 SF Porch ? 09 12-plex ? 14 Fireplace ? 21 Miscellaneous ? 05 SF Misc. ? 10 _-plex O 15 Deck WORK TYPE ?31 New 0 33 Alterations ? 36 Move ~[X 32 Addition ? 34 Repair ? 37 Demolition GENERAL INFORMATION Const. (Actual) 4ZJ2 Basement sq. ft. Census Code 44f (Allowable) Main level sq. ft. SAC Code -ey UBC Occupancy sq. ft. ~ Census Units Zoning sq. ft. Census Bldg # of Stories sq. ft. MC/ES System Length sq. ft. City Water Width Footprint sq. ft. Booster Pump PRV APPROVALS Fire 5prinklered Planning Building " Engineering Variance Permit Fee Co 1.0 0 Valuation: $ ,557OZ5~1 Surcharge / _ O Plan Review IJ xet =,36 ?r5 y°/ 9yy License MC/ES SAC City SAC Water Conn. Water Meter Acct. Deposit S/W Permit S/W Surcharge Treatment PI. Park Ded. Trails Ded. Other Capies . 7otal: 2 C) - 0~0 % SAC SAC Units PERMIT City of Eagan Permit Type: Building 3830 PILOT KNOB RD Permit Number: EA034720 EAGAN, MN 55122 D3tC ISSUPd: 03/17/1999 (651) 681-4675 Site Address: 896 Sunwood Ct Lot: 2 Block: 1 Addition: SLJNRISE HILLS 2ND ADDITION Description Sub Type: Porch/Addn. (4-season) ~ 3"'~Y UBC Oceupancy Work Type: New Z Canstruction Type: Descripfion: pilr Zoning: Census Code: Addition/Bsmt fin/Decks/Porch Sqg3ge Fe5;k:* OR, ~ stUtWtpNN,:°. T A 7i(Ed Remarks: Plan reviewed bv Wavne Miller. Separate permit required for any plumbing work. ;ctrical permit and inspections. ~ irge 1.00 69.00 $70.00 L"[7Y pG` L.n,r..;AN ii}111::.Fti, S 7L.fiM].N.A(.. ?,I0 g 9'19 ar=~ 0a/V3i99 rr.Mr. i..=oc4:!.-, 'JAi41=.. GUf:MElN IKlC ~-.1,`.i '300:I 896 Sl)idWClpLi f;r i.OD Owner: 3i'!.0 90r:l1. R'3F StJtJ1•Inr.7i7 LT 69 00 - Mike Gorman 896 Sunwood Ct ~ Eagan, MN 55123 651-687-0719 and state that the information is correct and agree to comply with all ;an Ordinances. i'oF,.a7. iP! Arcm~.:ritc 77:I.p0 CR 1. t14 065 is~ued By: Signature / 2 eL ~ CITY OF EAGAN CITY USE ONLY PLUMBING PERMIT SUBD. (612) 681-4675 RECEIPT # O ~O ' DATE RESIDBNTIAL PLEASE COMPLETE UPPER PORTION ONLY FOR SINGLE FAHILY DWELLINGS. ALSO, FOR TOWNHOMES AND CONDOS WHEN PERMITS ARE REQUIRED FOR EACH UNIT. WORK DESCRIPTION COMPLETE THE FOLIAWING: N0. FIXTURES EA. TOTAL NEW CONST ~ - REPAIR/ADD ON 15.00 /d.U7 ADD ON SHOWER 3.00 REPAIR WATER CIASET 3.00 BATH TIJB 3.00 LAVATORY 3.00 pyNEg pAME; KITC!{EN SINK 3.00 3.00 SITE ADDRESS: HOT~TUB/SPAY 3.00 WATER HEATER 3.00 FIAOR DRAIPI 3.00 GA3 PIPING OUT. INSTALLER: _ (MINIMUM - 1) 3.00 TOM HESSIAN PLUMBING, INC. _ ROUGH OPENINGS 1.50 ADDRESS: 404 ecnie.rnrm n,oAgrz _ OTHER - APPLE VAL! EY, MN 55124 _ WATER SOFfENER 5.00 CITY: ~ ZIP: ' _ PRIVATE DISP. 15.00 PHONE U.G. SPRINKLER 3.00 W. TURNAROUND 15.00 ` STATE SURCHARGE .50 ~ -~'SIGNATU E OF PERMITTEE TOTAL: S ~Sr.SZ~ ' COMMERCIAL PLEASE COMPLETE THIS PORTION FOR ALL COMMERCIAL/INDUSTRIAL BUILDINGS. ALSO FOR MULTI-FAMILY BUILDINGS WHEN SEPARATE PERMITS ARE NOT REQUIRED FOR EACH DWELLING UNIT. WOAK DESCRIPTION: OWNER NAME: CONTRACT PRICE: SITE ADDRESS: 1% OF CONTRACT FEE. . STATE SURCHARGE - $.50 FOR TENANT NAME: EACH $1,000 OF PERMIT FEE. SUITE $25.00 MINIMUM FEE. INSTALLER: CONIRACT PRICE x 1% $ ADDRESS: STATE SURCHARGE $ CITY: ZIP: TOTAL: S PHONE FOR. (SIGNATURE) CITY OF EAGAN . BRAU H ENVIFONMENTAL LABORATORIES Services Since 7957 ' MINNESOTA ENVIRONMENTAL TESTING Minneapolis AND CONSULTING SERVICES Hi6bing St. Cloutl Reply to address/phone p: Rachester St Paul RFFIIJFTED OfFICES „ NOATNOAROTp 6800 South TH-169 Bismarck wiuisron POSt Off1Ce BOX 35108 Minot M1III12dp0113, MN 54635 MONTAXA (612) 941-6491 Billings . 5` • - Bozeman ICY, ILLIM01$ Cnicaeo JdI1110 7 k'' 198~ u:"•--:',-~ - 71 ~ c_.i ~t WISCONSIX b:.".~.-, Milwaukee f Samerset - - h:'_:". Gi.'.h ? City of Eagan PaulRogerR V. Book.CPGBlomquist.Ph.D383O Pilot Knob Road . J.S. Braun. P.E. EdCJdII , MN 55123 Anne L OchsE AttEIltlOR: Mr. Mike Foertsch , D/~ p Gregory GAlson F• /Q f ~ Svn ~C: Sa ADDmo pFFILIFTEO COMPANIES BraunEngineering RE: E88-785 ENVIRONMENTAL SOIL BORING iesting INVESTIGATION 8raun PavemeM Technoloqies.lnc. SII71WOOd COII2't CIIl-dE-SdC Wescott Hills Drive Eagan, MN Dear Mr. Foertsch: In accordance with your authorization, Braun Environmental Laboratories, Inc. (BRAUN) conducted environmental soil borings at the referenced site (Site). The location of the Site is shown on the attached map. The purpose of these environmental soil borings was to identify the presence or absence of contaminated soil associated with the fuel pipeline on the Site. Three standard test penetration borings (ST-1, ST-2, and ST- 3) were completed at the Site. The results of the borings are summarized in this report. Soil samples obtained during the boring operations were scanned for the presence of volatile organic compounds (VOCs) by an on-site technician using an Organic Vapor Analyzer (OVA). No indications of existing soil contamination were encountered during the boring operations at the Site. OVA results are summarized on the attached OVA Field Data Sheets. Please refer to the attached report for a complete discussion of our analyses and conclusions. . E88-785 City of Eagan -2- January 17, 1989 We appreciate the opportunity to provide our professional services on this project. Should you have any questions regarding the contents of this report, please do not hesitate to contact us at (612) 941-5600. Very truly yours, BRAUN Environmental Laboratories, Inc. Gregg~ ~ Roch ford Environmental Geologist Paul R. Book, CPG Environmental Geology Manager Attachments: Site location map Site sketch Soil boring logs ASTM D 2487 GAR/PRB:jas\E88-785 Fumun~~ E88-785 City of Eagan -3- January 17, 1989 RE: E88-785 ENVIRONMENTAL SOIL BORING INVESTIGATION Sunwood Court Cul-de-sac Wescott Hills Drive Eagan, MN A. INTRODUCTION A.I. PurAOSe: The purpose of the environmental soil borings was to identify existing subsurface contamination at the Site based on the Scope of Services outlined below. A.2. Scone The services provided for this project consisted of the following: - Three standard test penetration borings (ST-1, ST-2, and ST-3) were conducted on the Site, and - Visual inspection and on-site monitoring of the soil borings with an orqanic vapor analyzer (OVA). Based on the results of these activities, this environmental soil boring report was prepared. A site history investigation was not within the scope oP services for this project. A.3. General Geoloaic Conditions: Surface deposits in the area of the Site consist of end moraine deposits associated with the St. Croix Moraine of the Superior Lobe, Late Wisconsin Glaciation (Hobbs, Goebel, 1982, Geologic Map of Minnesota, Quarternary Geology). The Ordovician bedrock surface below the area of the Site lies at an elevation of approximately 600 feet above mean sea level. The surface elevation at the Sita is approximately 900 feet above mean sea level, which indicates a depth of approximately 300 feet of unconsolidated glacial till. B~un E88-785 City of Eagan -4- January 17, 1989 Local groundwater flow was not determined. However, regional groundwater flow may be toward the Mississippi River to the north. B. TESTING B.I. Borina Locations and Elevations: The boring locations were selected on the basis of underground utilities and the location of the pipeline. Locations of the borings are shown on the attached site sketch. Elevations for these borings were taken using the manhole, located in the cul-de-sac of Sunwood Court, as a 100-foot reference. B.2. Field Testina and Samnlina: The penetration test borings were performed with a truck-mounted core and auqer drill. Sampling for the borings was conducted in accordance with ASTM D 1586 "Penetration Test and Split-Barrel Sampling of Soils". Using this method, the bore hole was advanced with the hollow-stem auger to the desired test depth. Then, a 140-pound hammer falling 30 inches drove a standard, 2-inch OD, split-barrel sampler a total penetration of 1~ feet below the tip of the lead flight of the hollow-stem auger. The blows for the last foot of penetration were recorded and are used as an index of soil strength characteristics and for stratigraphic correlation. Samples were taken at 5-foot intervals to the termination depth of the borings. B.3. Groundwater Measurements: Immediately after taking the final sample in the bottom of the boring, the bore hole was probed through the hollow-stem auger to check for the presence of groundwater. Immediately after withdrawal of the auger, the bore hole was again probed and the depth to water or cave-in was noted. The boring was finally checked and then backfilled in accordance with the Minnesota Department of Health Water Well Construction Code prior to leaving the Site. B.4. Soil Classification: Soils encountered in the borings were unTM BRA E88-785 City of Eagan -5- January 17, 1989 visually and manually classified in the field by the crew chief in accordance with ASTM D 2487 "Unified Soils Classification System° and ASTM D 2488 "Recommended Practice for Visual and Manual Description of Soils". A copy of ASTM D 2487 is attached. All samples were then returned to the laboratory for review of the field classifications by an environmental geologist. Representative samples will remain in our Minneapolis office for a period of 60 days to be available for your examination. B.5. Contamination Detection Procedures: During the field sampling, soils were inspected visually for unusual staining as well as scanned with an OVA to determine if hydrocarbon vapors were present. C. RESULTS C.1. Loas: Log of Boring sheets indicating the depths and descriptions of the various soil strata, the penetration resistances, and water level information are attached. The depths shown as changes between the strata are approximate. The actual changes may be transitional, and the depths of the transitions likely vary horizontally. C.2. Groundwater Measurements: Groundwater was encountered in the soil borings at depths ranginq from 16 to 18 feet with the hollow-stem auger in the ground. C.3. Soils Encountered: Generally, the soil borings encountered sandy silt, fine- to medium-qrained with some roots and pebbles. ST-2, taken in the bituminous pavement of the cul-de-sac, encountered approximately three inches of bituminous and the underlying sandy silt fill. Below this fill was approximately 18 feet of poorly graded sand which was considered to be fill, added pursuant to pipeline leak associated soil abatement. The mottled soils encountered in ST-3 may have been displaced from the area of ST-2. BRAun'4 E88-785 City of Eagan -6- January 17, 1989 C.4. Contamination Detected: Hydrocarbon contamination was not detected in the soil borings with the OVA meter. Further analysis, therefore, was not conducted. (See attached OVA Data Sheets.) D. CONCLUSIONS Our on-site observations revealed no unusual staining in the soils sampled. In addition, the scanning of soil samples did not indicate detection of hydrocarbon vapors in the soil borings. It appears that the soils sampled are not contaminated with VOCs or petroleum product. E. GENERAL The analysis and recommendations submitted in this report are based upon the data obtained from the soil borings performed at the locations indicated on the attached site sketch. Subsurface contamination was not detected in our borings. Based on the existing pipeline locations, the borings were placed in areas that would not disrupt underground utilities and, in our opinion, would best intercept subsurface contamination. Services performed by the geologists and environmental scientists for this project have been conducted in a manner consistent with that level of care and skill ordinarily exercised by members of the profession currently practicing in this area under similar budget and time restraints. No warranty, expressed or implied, is made. BRAuR- . . Page 1 of 2 OVA. Field Data Sheet , Project Number: E88-758 Date• 12/21/88 Location: Sunwood Court Cul-de-sac Auqer Steam Cleaned? Y N weather Conditions: Split-Spoon Cleaned between Calibration: samples? Y N Boring ID: ST-1 Method: Head Space Depth of Auger Cuttings Split-Spoon Analysis SamDle (Apm) (nnm) (topml Notes 2.5 0 0 5. p p 10. 0 0 15. 0 0 20 0 0 Location: See sketch Date: _ 12/21/88 Weather Conditions: Auger Steam Cleaned? Y N Calibration: Split-Spoon Cleaned bween Boring I.D.: ST-2 samples? Y N Method: Aead Space Depth of Auger Cuttings Split-Spoon Analysis Samole fppml fppml (ppml Notes 2.5 0 p 5. 0 0 10. 0 0 15. 0 0 20. 0 0 iiRAunj . Page 2 of 2 UVA Field Data Sheet Project Number: E88-785 Date: 19171 /RR Location: See sketch Auger Steam Cleaned? Y N Weather Conditions: Split-Spoon Cleaned between Calibration: samples? Y N Boring ID: Method: Head Space Depth of Auger Cuttings Split-Spoon Analysis Samvle fooml fopml (ppml Notes 2.5 0 0 5. 0 0 10. 0 0 15. p p 20. 0 0 Location: Date: Weather Conditions: Auger Steam Cleaned? Y N Calibration: Split-Spoon Cleaned between Boring I.D.: samples? Y N Method: Head Space Depth of Auger Cuttings Split-Spoon Analysis Samole fppml (npm) (aoml _ Notes GRAUR V r / u~ tV ~ J l ~ ~ • Vfi ~ 1 V ` .4~~~i I ~.1 a 4 ~ ~ i 1'v i ~ f •/I( ~ l ~ ~ 1~ ~I U - \1 GFevelPi! U~ I iQ ) T fo, P~ . ~ - .m~~~`~c,, ~~l ~Q~'.~' v.~`'°~,•-,' ` f2Cl ~ ~ ~ ~C..~`~> `,~,11 ~ p r ~ _ . '~a H ~ p ~ ~ i ~ , ~ _ . • ~ p - C ~ . ee~ _ °'Z ~ i '~t ~ o Carr aea MiAS' 'Cavntry C " - O ~~:.q~:. m / .:-.n~ i ~ . . _ . ~ ^tJ• ~ Fzali~,,,, Site Locationr E88-785 • ' en ~ • _ ' O ~ ,~.`T~7 ~ r ~ p1 ~ o e~ w rr xo •~e»~1 ~i7 -;5 Ftso G~ -,o't C ~ ~J ! \ ] 0.,~V - cCarthy;~ a v ~j}0 q' 'ty ~ ~ ,rF" . ~ ' X = • ; ee~ _z y~. ' p _ e /"j • ' ~ l- ~ ,o Y T , ! ~ u'" ~ ~ - enG' '00 ~ ST. PALfL SW QUADRANGLE MINNESOTA 7.5 MIIVUTE SERIES (TOPOGRAPHIG) SM'N 5T. PAUI 13 ' DUADRANGLE E88-785 City Of Eagaa Sunwood Court, Cul-de-sac to west BRAUP] of P7escott Hills Drive Fagan, Ydinaesota o.te:Jan 188 Ravird: Dnwn: 3a$ SaN1'20 000 N ~ ~ - Boring Locations ST-3 ~t ~ H a A m 51' a H H O sotawoon COURT u ul 54 93' 29,' ~ A. ST-~/ ~ 91 ST-1 w`Q Jan 188 E88-785 City of Eagatt Sunwood Court, Cul-de-sac to west of Ravimd: BRAH ~ Wescott Aills Drive °"w"GAR Eagan, P7innesota Not to Scale nommom . LOG OF BORING [BKAUH • ENGINEERINfi TESTING PROJECT: E88-785 INVIRONPIENTAL SOIL BORINGS BORING: ST-1 City of Eagan LOCATION: 3830 Pilot Knob Road Eagan, h4V 55123 See Attached Sketch DATE: SCALE: = t,' ASTM Tests or Notes Elev. Depth D2487 Description of Materials BPF WL 100.4 0.0 Symbol (ASTM D2488) 98.9 1.5 SM FILL: SILTY SAND, brown, frozen. BIIVCH MARK: Hydrant at west end of cul- hII. FILL: SILT, with Roots, black, de-sac on Stmwood 97.4 3.0 d Tonsoi.l) Court. hII, SANDY SILT, fine- to mediian- grained, brown, moist, stiff. 95.4 5.0 (Glacial ' 14 h1L SANDY SILT, fine- to meditmi- grained, with Gravel, brown, o moist, very stiff. o (Glacial Till) c E . a~ ~ 90.4 10.0 21 a hII. SAIVDY SILT, fine- to mediiun- y grained, with Roots and Gravel, D brown, wet, very stiff. v (Glacial Till) c m • c 0 ~ 85.4 15.0 27 m d ML SANDY SILT, fine- to mediLnn- o grained, with Gravel, brown, ; waterbearing, very stiff. a (Glacial Till) 'R A ~ o 30 r~5 ~ END OF BORING m a Water level down 16' with 20' of d hollow-sten auger in the ground. ¢ v~i Water level down 16' imnediately after wi.thdrawal of auger. Boring irtmediately backfilled. . LOG OF BORING BRAVII ENGINEERING TESTING PROJECT: g88_785 FNVIRONMENTAL SOIL BORINGS BORING: ST-2 , City of Fagan LOCATION: 3830 Pi1ot Knob Road Eagan, hIIV 55123 See Attached Sketch. DATE: 12/21/88 SCALE:1" = 4' ASTM Tests or Notes Eiev. Depth D2487 Description of Materials BPF WL 98.1 0 Symbol (ASTM D2488) SM FILL: 3' BITUMINOUS Pavement overlying SILTY SAND, brown. 96.1 2.0 SP FILL: POORLY GRADID SAND, mediian- to coarse-grained, with Gravel, brown, moist, dense. 93.1 5.0 23 SP FILL: POORLY GRADED SAND, mediian- to coarse-grained, witn rn Gravel, brown, moist, mediian 0 o dense. a E . a~ > 88.1 10.0 15 n 5P FILL: POORLY GRADED SAND, ~ medit¢n- to coarse-grained, with ~ Gravel, brown, moist, loose. ~ c ~ c 0 ~ 83.1 15.0 8 SM SILTY SAPID, mediinn- to coarse- o grained, with Gravel, brown, wet, loose. (Glacial Till) m a a ~ A ~ 77.6 20.5. 5 ~ ETdD OF BORING. a Water level down 18' with 20' of ¢ hollow-stan auger in the ground. m cn Water level down 18' imiediately after withdrawal of auger. Boring 'umediately backfilled. . . LOG OF BORING [IIKAU~1 . ENGINEERING TESTINO PROJECT: E88-785 INVIRONMENTAL 50IL BORINGS BORING: ST-3 City of Fagan LOCATION: ' 3830 Pilot Knob Road Eagan, MN 55123 See Attached Sketch. DATE: 1,2/91/88 1 SCALE: _ 1 ASTM Tests or Notes Elev. Depth D2487 Description of Materials BPF WL 105,4 0,0 Symbol (ASTM D2488) SM FILL: SILTY SAND, brown, moist. 7 SP FILL: POORLY GRADED SAND, T medium to coarse-grained, moist, o loose. 'o c E ~ m m 95.4 10.0 Zg ML FILL: SANDY SILT, meditm- m grained, with Gravel, brown a mottled with cdnite, moist, very ~ stiff. c 0 ~ 90.4 15.0 ; 25 ~ hII., FILL: SANDY SILT, meditun- .R grained, brown, mottled with m white, moist, very stiff. m `a a m ~ C 84.9 ~ - *grained, brown, wet, ~ IND OF BORING. very stiff. (Glacial Till) ~ $ Water level down 18' with 20' of cc hollow-stem auger in the ground. m rn Boring i.nmediately backfilleri. Descriptive Terminology Designalion D 2487 - 83 , Standard d Test Method for CLASSIFICATION OF SOILS FOR ENGINEERING PURPOSES :oi~ aassincano. PARTICLE SIZE IDENTIFICATION I CYItA4 f00. 4IIIGx:NG fR00> SYMBULS AYD pWV I GR00P XAfS US:XG UBWAIOtY if5i5 a SYMBpI q10UY XH1F e Boulders , overi ' ranveu nerm r~e~~cis a .a i a c< < 3 e r~ rn-q.eaea q.,.el r I Cobbles 3" to 12.. ~a - i _ ro.< <n.. sm al . a,: :nan si rne, ~ Gravel .«e1o, . .~aio. l cv oeo.lr 9..em Coarse . 14.• - 3.. e . ..t.+e~a ~ I W: s I m. a sI<.e 1 anv[~s ~rtx ruts ' n1 es <ins~I as ri o. nx ea sm ....i ~•s" I Fine.............................. No. 4-1/4" ;ro.emen;nrmuc r. _ ~mn cpr:~rr a: tt o. a u u.xi 9.a~~ 9•n ~ Sand ! ^ I s4xoz RGx snxps > 6 a.a I < cc < 3 e 5y yNi I-ynleo zme I . . . . . . . . . . . . . . . . . . . . . . . . . I sas o, u.. m.N ss n'.l a Coerse . N0. 4- No. 10 ~ ~ e.:vc„ 1 a.oaie. i; c, > 3< sr eoonr c•W•a ..na ~ Medium . . No. 10 - No. 40 s ° a ! se.os unx vixes ~ rsn.: Ci.,sn e: xL o. nx sn mi ..ee Fine No. 40 - No. 200 A IE ' lbre tMn 114 M1nes 0 f'nes olasv~ly as Cl ot C. SC Cl~~e~ tmE 9.41 . . Silt No.200 - .005 mm o1e1: o1 or mo.: a «r n.r A.I.I. I Clay ICSS ihan.005 mm ~ SitTS CI ~ 4 plc[5 E[1p. 'P' Iin< ) ML $lIt \.I m I RELATIVE DENSITY OF ~ . uW4 - a.'.a as.F~~ o.. I. I. COHESIONLESS SOILS orgm a L(Cm _ na~ Jr~M ` 0]S Ot (r9an f.lt 1, A. o I „ i ry oose .0- 46PF ve p, pio« o . i e_ . o. c.,: - s :.,e cx v.v ner . . . . . . . . . . . . . . . . ~T Ioose 5- 10 BPF medium tlense 11 - 30 BPF ~ Uaoi: : nn - v; ;ims oNo. A. l,rc nx uno,c suv W.m tlense 37 - 50 BPF i... v i very dense 50+ BPF w mz~^ ~fd""fimie - noi drTea `o.rs w~ 0. e ~ni . e II, 111:s.. 1,1~ 11 1.1.1. ~IA 'I v<•l ~gntporqan¢aarls w arga.n[ . n1` I CONSISTENCY OF COHESIVE SOILS I a. aa.ea o~ ~ne .,eu.a', o,.s.... me j.,, vs-mml ne.e. vZry Sott . 0- 1 BPF c. ~r r.ie ....o~. «~u~.< .ooo'es a~a:o. mween. aca -.11n meo:<x a1m~, w-,m..:- m s•o.o l..e. SOft 2- 3 BPF L. e....l.. ~ s io ~n rinea oual s,eAai. . 4- 5 BPF ~r 9.mec v,.ei ~n rather soft , a-a k. a-ec ..n g.m:a r.,.ei medium . . • • . • . • • • 6- 8 BPF 4~-4X Mo.IY 3rtle< 9~a~tl ~tt~ tlt 6a-e; ~aon> ~..i.e g.e.e',m o.r rather stiff 9 - 12 BPF A. se.a: .n, f ro.a . es ~ee~~e a+.~ :paois sy-v e~T 9.aaea se~e .lu ,u 51iff . 13 - 16 BPF . W ..:i y.aa.a 5a.a .rm ae. ver stiff . 77 - 30 BPF Sv.vn ooo.~y a~+~ee ..Fe nm srn Y sv-s: ooa•:y y..em s.na .111 01, h0rd 30+ BPP IoJOit Cu ~ D60ID14 C ~ ~ .aa -.It, ,..a. 9.0.~ DRILLING NOTES g. ~I llnes olasxly a:LJIL. u e Eual s~nOOl LC-4Y. SC-Y1. 11 fines e orgenrt. a4E '.iliN argOnl[ Hnes' to 9'ou0 n n. il so.l <o.tans ~ 152 yarp^, aE0 '.im qsove~^ te y~ouo~ . , 'i.,. Standard penetration test borings wereadvancetl by 3bs. or 6'/=" .p u>ae.e..A ~~m1~, io~ ..e,, u~. , as n w~ 'a ~s ~s vo z9: oi.s ~w. soo. ~aa ~.~m se•e~ .•.im ya• .n~rne..r o.eam~+~em. i: n,an ~o~~~;~: ~ 3m m~, m. :oo. ~m~+..~~~r „~e, .aa ,..er ~e n.a~o I.D. hollow-stemaugers unless noted otherwise. Jetting waterwas if w1 tonta~ns = 30i plus K. 'W. D~MminanUY 9nve1. aaE'9.~•e11Y to yroop nx. ,:,.".,aviatyo,o,no.e.p-„ne. usetltocleanoutaugerpriortosamplinqonlywhereindicatedon L. e.lo. 'n' un.. logs. Standard penetration test borings are designated by the a. vi o a"s cao :p„~.~ prefix "ST" (Split Tube). ~ Power auger borings were advanced by 4" or 6" diameter. I~o~ :~sss+~mro., o+ •~~e-~~o,~m sms ~ continuous-flite, solid stem augers. Soil classification and strain .,or depthsareinferredfromdisWrbedsamplesaugeredtothesuAace smis and are therefore somewhat approximate. Power auger borings i+ w F are designated by the prefix "B". x ' Hon:on.o~ a* ~L=a 255, ~„i o wF -0p. o;-'"' `•.ZG! `~i ~ -i~ Hand probings were advanced manually with a 1'h" diameter z eouot,on eF "u'-.~e -a probe and are limited to the depth from which the probe can be verriicoi at =ie rooi=' G~~ ~ manually withdrawn. Hand probings are indicated by the prefiz _ w H.. F tnen~i=09;1~-81 i . 2 SAMPLING - All samples are taken with the standard 2" O.D. ~V I split tube sampler, except where noted. TW indicates thin-wall a 20 i 8 MH a' OH (undistur6ed) 5ample. i BPF - Numbers indicate blows per fool recorded in standartl ~o penetration test, also known as "N" value. The sampler is set 6' ML OL into undistur6ed soil below the hollow-stem auger. Driving e-- - resistances are then counted for second and third 6" increments °o 10 1 s zo ao .o so so IFo w vo ~oo uo antl added to get BPF. Where they differ significantly, they are LIOUID l~M1T ILL) reportedinthefollowingform-2n21orthesecondandthird6" increments respectively. WH - WH in0icates that sampler penetrated soil under weigM of hammer and rods alone, tlriving not required. NOTE - All tests run in accordance with applicable ASTM LABORATORY TESTS standards. DD Dry Density.. pct OC Organic Conten[, % WO Wet Density, pcf 5 Percent of Sawration, % MC NaWral Moisture ConrenL % SG Specific Graviry LL Liquid Limit. % C Cohesion PL Plastic Limit. % 0 Angle of Intemal Friction PI Plasticiry Index, °ro qu Unconfinetl Compressive Strength RESIDENTIAL BUII.DING Permit Application City Of Eagan 3830 Pilot Knob Road, Eagan Mn 55122 ~ Telephone # 651-675-5675 FAX # 651-675-5674 NawConshucdonReauiremenb RemodeVReoairReauirements OlficeUseOnN 3 registered site surveys sha.viig sq. ft ol bt sq. R af house; arM II roofed areas 2 copies of plan _ Cert of Survey Recd (20% maximum bt coverage allovred) t set of Eneyy CalaMons tor heated addNOns Tree Pres PWn Rerd 2 capies of plan showing beam 8 vrindax sixes; poured found design, etc. t sHe survey far additlons 8 decks Tree Pres Not Reqd 1 set of Energy CakulaNons Addition - indicafe Han,site septic system _ On-sile SepGc System 3 wpies of Tree P2sena6on Plan if bt platted afler 7l1193 Rim Joist Dehad Options selection sheet (bklgs wBh 3 or less unils Date ~-7 /~~t•1/ Construction Cost l, ~ ~ Site Address 9/(9 JU'SI~Od C()IJ'C-L UniUSte # Descriptlono(Work ~CQ a t~~.o~~~ ty~~{l~.v1.PJ1uS'~'1'(~ Multi-FamilyBldg _ Y_ N Fireplace(s) _ 0 _ 1 _ 2 Property Owner (n lik.Q., 6-16(frlul.( v Telephone # ~11751 Q Contractor RENEWAL BY ANDERSEN Address 1920 COLJN'IY ROAD "C" WEST City ROSEVILLE, MN 55113 - State 651-264-4777 zphone # ( ) LICENSE #20130983 EW BUILDING RUCTING A N COMPLETE THIS AREA ONLY IF CONST - Minnesota Rules 7670 Cate o - ~esota Rules 7672 Energy Code Category • ResidenUal VenGlation Calegory 1 r orksheet . 1:I . j New Energy Code Worksheet (J submission type) Submitted I Ji~ SubmiUed . EnergyEnvelopeCalculationsSu~ilOedl~~r i 5 I L Licensed Plumber ! Telephone ( ) Mechanical Contractor Telephone ) Sewer/WaterContractor Telephone#( ) I hereby apply for a Residential Building Permit and acknowledge that the infortnation is complete and accurate; that the work will be in conformance with the ordinances and codes of the City of Eagan and the State of MN Statutes; I understand this is not a permit, but only an application for a permit, and work is not to start without a permit; that the work will be in accordance with the approved plan in the case of work which requires a review and approval of plans. ~GI.~CA 4n.OL~~ ApplicanYs Printed Name pplicanYs Signature zoos RESIDENTIAL PLUMBlNG PeRnniTaPPUCaTtoN ' CITY OF EAGAN , 3830 PILOT KNOB ROAD, EAGAPI MN 55122 651-675-5675 Piease complete for modifications to existing residential dweliings. Date _10 9 2~_ I _ SCHMIDT, KRISTINE Site Street Address $95 SUNWOOD COURT - EAGAN, MN 55123 Ulll! # ' (651) 452-2762 Property Owner Telephone # ( ) Contractor NorLil(7YY1 I'~~.L{'YCbI n q Telephone# ((dIY) 9'17-q0;~:3 Address 29D5 C~ar-~ e~d t~-v. 50. ciri rYt aIs State rY1 N zip r-f-108 The Applicant is: _ Owner V Contractor _Other Sept(c System _ New Refurbished Submit 2 sels of pians and MPC license Includes County fee $ 100.00 ' Per as-built $ 10.00 Alterations to existing dwelling $ 50.00 _ Add plumbing fixtures. This fee includes installation of a water softener and/or water heater at the same time. !f you are (nstalling anly a water so(fener and/or water heater, do not complete this section; move to the next section and check the appliance(s) you are installing. . _Septic System Abandonment ~_Water Tumaround (add $130.00 if a 5/8" meter is required) Other: Water Sokener /Water Heater $ 15.00 _ new V repiacement Lawn Irrigation _RPZ _PVB _new _repair _rebuild $ 30,00 State Surcharge $ .50 Total $ ~ 5 .5~ I hereby apply for a Residential Plumbing Permit and acknowledge that the information is complete and accurate; that the work will be in conformance with the ordinances and codes of the City' of Eagan and the plumbing codes; ihat I understand this is not a pertnit, but only an application for a permit, work is n t to start without a permit and work will be in accordance with the approved pian in the event a plan is required"to be vi ed a approved. Jef;FreLi L. N o rWoryi Appkicant's Prin d Name AppliCanYs Signature y ~ CASH REUIPT.,., CITY OF EAGAN 3830 PILOT KNOB ROAD EAGAN, MINNESOTA 55122 DATE 19 ' RECEIYED f1101I na+ourrr $ 8 DOUARS loo ? CASH C~ CHECK _ FUND OB.IECT AMOUNT Thank You BY C f wwoa--Pft-8 cwy reIWw-Posunu CqPr ftIc--Fia Copy City of Eagan 3830 Pilot Knob Rd Eagan, MN 55122 (651) 675 -5675 www.ci.eagan.mn.us Site Address: 896 Sunwood Ct Lot: 2 Block: 1 Addition: Sunrise Hills 2nd PID:10- 72983 - 020 -01 Use: Description: Sub Type: Work Type: Description: Census Code: Zoning: Square Feet: 0 Comments: Fee Summary: Valuation: 3,000.00 Contractor: Renewal Andersen 1920 County Road C West Roseville MN 55113 (651) 264 -4777 e- Windows/Doors Windows/Doors-New/Replacement House 434- Applicant/Permitee: Signature PERMIT City of Eaan Improvements to the home require smoke detectors in all bedrooms. If altering window openings, call for framing inspection. Call for final inspection after installation. Carbon monoxide detectors are required by law in ALL single family homes. BL - Base Fee $3K Surcharge - Based on Valuation $3K Construction Type: Occupancy: $88.50 $1.50 Total: $90.00 - Applicant - Owner: Michael L Gorman 896 Sunwood Ct Eagan MN 55123 Permit Type: Permit Number: Date Issued: Permit Category: 0801 9001 I hereby acknowledge that I have read this application and state that the informa of Minnesota Statutes and City of Eagan Ordinances. on is correct and agree to comply h all applicable State Issued By: Signature Building EA089474 06/02/2009 ePermit Use BLUE or BLACK Ink r For Office Use CC____ Permit#: 2/61:2 --> City of Eaaari Permit Fee: /G" - - 3830 Pilot Knob Road Eagan MN 55122 Date Received: Phone: (651)675-5675 Fax: (651)675-5694 Staff: 2016 RESIDENTIAL BUILDING PERMIT APPLICATION Date: //-/ "//‘ Site Address: �/ -Ck 1 w00d G �c` L` Unit#: Name: 1(� P/ i ��-U�� IA) Phone: 6/z, 7YO 3070 Resident/ Owner Address/City/Zip: 0 p[ b 5 u/Arw ' O e Applicant is: Owner Contractor Type of Work Description of work: J .e YO(_)T yp i (�J� I Construction Cost: t /fi, OU O Multi-Family Building: (Yes / ) s, Company: S0/AT P-01'01 ( $i l'/) ..TNCContact. �yGt/4 4rGP /4QQ / Address: /L//Cb 49/(6/0/i' 6 All& City: i?(--) e-ril CAA fA Contractor VIA D sO�i - 6 Y/6¢s' s 5�r41`f. . State: Zip: Phone: Email as , 4 License#:136-6369 Z v Lead Certificate#: If the project is exempt from lead certification, please explain why: COMPLETE THIS AREA ONLY IF CONSTRUCTING A NEW BUILDING In the last 12 months, has the City of Eagan issued a permit for a similar plan based on a master plan? Yes No If yes, date and address of master plan: Licensed Plumber: Phone: Mechanical Contractor: Phone: Sewer&Water Contractor: Phone: Fire Suppression Contractor: Phone: NOTE: Plans and supporting documents that you submit are considered to be public information. Portions of the informationmay be classified as non-public if you provide specific reasons that would permit the City to conclude that the are trade secrets, CALL BEFORE YOU DIG. Call Gopher State One Call at(651)454-0002 for protection against underground utility damage. Call 48 hours before you intend to dig to receive locates of underground utilities. www.gopherstateonecall.orq I hereby acknowledge that this information is complete and accurate; that the work will be in conformance with the ordinances and codes of the City of Eagan; that I understand this is not a permit, but only an application for a permit, and work is not to start without a permit; that the work will be in accordance with the approved plan in the case of work which requires a review and approval of plans. Exterior work authorized by a building permit issued in accordance with the Minnesota tate Building Code must be completed within 180 days of rmit issuance.. x ;(--c`�(�`J Qqfx jy� �G�/✓ Appli ant's Printed Name Appli tsSignature Page 1 of 3