Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
1708 Terra Glenn Ct
INSULATION INSPECTION CHECKLIST FOR RESIDENTIAL BUILDING PERMITS PROPERTY LEGAL: ©+ PROPERTY ADDRESS: /L -7() -r-Om G i e mn-) C i' INSPECTOR: Le1AI LC?e (0.1)d INSPECTION DATE: U) o ¢ } z z SITE GRADING ? ? All slopes 3:1 or flatter? ? ;K ? Slopes steeper than 3:1 require retaining wall. Are retaining walls present? ? ? Does grading conform to As-Built Grading Plan (+/- 1 foot approximately)? ? ? Does perimeter grading tie in well with adjacent properties/undisturbed land? ? ? ? r Is there proper grading and/or drainage around Lookout or Egress Windows? EROSION CONTROL ? ? ix Is Silt Fence (or approved equal) installed and in good working order? ? ? Is Sod/Fiber Blanket installed behind curb? ? ? Is the Rock Construction Entrance/Driveway installed and in good working order (proper type/size of aggregate, clean-not covered with soil, etc.)? 75 ? ? Is temporary vegetative cover w/ mulch present? ? ? Is permanent vegetative coverQw or w/o mulch present? (circle one) CITY EASEMENTS AND UTILITIES ? ? Are all easements clear-no part of any building/deck/porch/retaining wall/etc. encroaching in easement? ? ? Are catch basins present within the property or in the street in front of the property, if so are they clean, do they have the proper erosion control in and/or around them? ? ? $i, Does the property have an Emergency Over Flow (EOF)? This can be found on the / Certificate of Survey. If so, is it present and has it been graded properly? MISCELLANEOUS ITEMS ? ? Is there tracking present on Public Right-of-Way/Street from construction site? ? ? Is the driveway at the proper width at ROW line? (22 ft. max.)(Curb stop is at ROW line) ? ? Is the site clean, no trash and/or construction debris lying around? ? ? Was the proper type of building constructed according to the approved grading plans? (LO, WO, FB, R, etc.) Address: 1708 Terra Glenn Ct Zip: 55122 Permit: 81558 THE FOLLOWING ITEMS WERE/WERE NOT COMPLETE AT FINAL INSPECTION ON: Yes No Comments Final grade - 6" from siding Permanent steps - garage Permanent steps - main entry Permanent driveway 1C) Permanent as ?o Retaining Wall or 3:1 Max Sloe fp Sod/Seeded lawn Trail/curb damage Porch Lower level finish Deck Fireplace lf)O 24Z ?CAM d-/1' A;el ?? • Verify with your builder that roof test caps from the plumbing system have been removed. • Turn off water supply to the outside lawn faucets before freeze potential exists. • Call the City's Engineering Department at 651-675-5646 prior to working in right-of-way or installing irrigation system. y BUILDING INSPECTOR: 2G/Bldg Insp/Forms/2007/Checklists 952 445 7487 Line I Date: 112117/2007 Revision Date: 1 211 7/2 0 07 Slte Information Address 1: 1708 Terra Glen Ct Address 2: City: Eagan County: Application Information Business Name: Elander Mechanical Inc. Contact Person: Todd 09 00:26 a m 12-17-2007 1 .'1 New Construction Project 9: Lot: Block: Subdivision: MN Contractor License #: Office Ph: 952-445-4692 Fax: 952-445-7487 Cell Ph: Address 1: 591 Citation Drive City: Shakopee State: Minnesota Zip Code: 55379 House Details Square Feet: 5443 sq. ft. Avg. Ceiling Ht: 9 ft. Number of Bedrooms: 4 Ventilation : Balanced Total Ventilation Capacity : 214 cfm. Minimum Continuous Ventilation :75cfm. Intermittent Ventilation: 139 cfm. Combustion Appliance Water Heater: Power Vent Input BTUs: 75,000 Independently Vented Furnace/Boiler: Direct VentlSealed Combustion Input BTUs: 110,000 Independently Vented Other Combustion Appliances Gas Fired Direct Vent Fireplace(s): Yes Gas Fired Power Vent Fireplace(s): No Gas Fired Natural Draft Fireplace(s): No Solid Fuel Appliance(s): No Exhaust Equipment Continuous Exhaust Ventilation Capacity (cfm): NA Clothes Dryer (cfm): 135 Exhaust Fan Rating (cfm): 640 Make-Up Air No Make-Up Air Required by Code Combustion Air Round Rigid Required: 5 inches or Insulated Flex: 6 inches Applicant Name (print): J D A-RQrc! SignatureiDate lz (l J ?9 ? -- Code Cificial © 2004 CeuterPoint Energy hlim;egasco. 2004 Mechanical Code Guideline.a. Page l ? Site address: l-(o8 f e-pct G taKy /Lot Block fi=t Subd. On April 15, 2000 the Minnesota Energy Code, Category I Building Requirements for insulation protection, air tightness, and ventilation, was adopted. As a result, the City of Eagan is requiring that the following information be submitted prior to issuance of a Certificate of Occupancy. This structure: is constructed to meet minimum requirements of the Mn Energy Code, Chapter 7670 OR This structure: will be constructed to meal more restrictive requirements of Chapters 7672 or 7674 APPLIANCE GAS ELEC MANUFACTURER MODEL BTU'S VENTING TYPE Water Heater Furnace o S 80400 V c-, Dryer f=i nv 150 0 (00 12 0 \100 Tiv C. G L b c-\f 'A v. a v- W UD 2-1 100 EXHAUST SYSTEM LOCATION TYPE MODEL CFM's VENTED YES NO Kitchen kitchen ?'E J qbb b 55 Bathroom 1 lvo0 Bathroom 2 3 ror V-- A& SS,o Sb >C Bathroom 3 -? Bathroom 4 izF M SD So x S?ev- ?jgoak L7- hl 6-0 ( l00 Other FIREPLACES LOCATION GAS WOOD MANUFACTURER MODEL BTU'S- DIRECT NTI AGMOS ^^`? ?.'v Z3b 30 000 X r. r. MAKE-UP AIR MODEL F TYPE kE Qr. ! E 2•Z_ 4w-a H Mtl I hereby acknowledge that the above Information is correct and agree to comply with the Minnesota Energy Code and City ol'Eagan requirements. _ 1 . 5-06 + Sign ure Company Name Date This form-is the responsibility of the General Contractor. City of Eagan Mike Maguire MAYOR Paul Bakken Peggy Carlson Cyndee Fields Meg Tilley COUNCIL MEMBERS Thomas Hedges CITY ADMINISTRATOR MUNICIPAL CENTER 3830 Pilot Knob Road Eagan, MN 55122-1810 651.675.5000 phone 651.675.5012 fax 651.454.8535 TDD MAINTENANCE FACILITY 3501 Coachman Point Eagan, MN 55122 651.675.5300 phone 651.675.5360 fax 651.454.8535 TDD www.cityoteagan.com THE LONE OAK TREE The symbol of strength and growth in our community. January 2, 2008 Lennar 545 Indian Mound Blvd. E Wayzata, MN 55391 RE: Incorrect SAC Fee 1708 Terra Glenn Court To Whom It May Concern: While performing our month end report for December 2007, it was noticed that Lennar was incorrectly charged on the Metropolitan Council SAC fee. You were charged the 2008 fee of $1,825, instead of the 2007 fee of $1,675. To correct this error, you will receive a check in the amount of $150.00 under separate cover. Please accept our apologies for this inconvenience. If you have any questions regarding this refund, please do not hesitate to call me at (651) 675-5671. Sincerely, Sarah Brandel Office Supervisor Cc: Dale Schoeppner, Chief Building Official City of Eap Make Check Payable to Address: Permit #: EA081558 Site Address: 1708 Terra Glenn Court Reason for Refund: Incorrect SAC Fee Lennar 545 Indian Mound Blvd. E Wayzata, MN 55391 Claim Vo tk TYPE OF REFUND Building Permit Base Fee 0801.4085 $ Construction Meter Dep Refund 9220.2254 $ Curb Box Deposit Refund 9220.2253 $ Fire Suppression Permit 0801.4096 $ Mechanical Permit 0801.4088 $ Plan Review Fee 0720.4222 $ Plumbing Permit 0801.4087 $ SAC (MCES) 9220 2275 $ 150.00 SAC (City) 9379.4681 $ SAC Admin 0801.4246 $ Sewer Permit 6201.4532 $ Surcharge 9001.2195 $ Treatment Plant 6101.4685 $ Water Permit 6101.4507 $ Water Meters & Radio Read 6101.4509 $ Water Supply & Storage 6101.4680 $ Copies 0201 4230 $ Total $ 150.00 h b en aid I declare under the penalties of law that this account, claim, or demand is lust and that no part of it as e p l SIGNATURE DATE - P? ?rss?j ?io.so ©s0 2006RESIDENTIALBUILDINGPERMITAPPLICATIONI" City Of Eagan CL/ 3830 Pilot Knob Road, Eagan MN 55122 Telephone # 651-675-5675 FAX # 651-675-5694 New Construction Requirements RemodeilReoan Requirements 3 registered site surveys showing sq. ft. of lot, sq ft. of house; and all rooted areas 2 copies of plan showing feelings, beams, joists (20%maximum lot coverage attend) 1 set of Energy Calculations for heated additions 2 copies of plan showing beam & window sizes, poured found design, etc 1 site survey for additions & decks t set of Energy Calculabons Addition - indicate if on-site septic system 3 copies of Tree Preservaeori Plan if eel plaited after 771!93 Rim Joist Detail options selection sheet (buildings wiN 3 or less units) S- cy ' Minnegasco mechanical ventilation form 7 Office Use Cot Ced of Survey Recd _• 1, j_ N Tree Pies Plan Recd i-Y _ N Tree Pres Required tCY N On-site Sepllc System _Y _'N Date _ Construction Cost Site Address ( v-v- Unit/Ste # to I if 0 Description of Work 15C D ` Multi-Family Bldg _ Y _, N Fireplace(s) _ 0 _ 1 ? 2 Property Owner ?@YsvWV-• Telephone#( ) Contractor ?QY?,nec'I- Address ScIJ ?u.c4 tcVrn 1 w1GLA,<O/ 13 WCt City UJo_•{ 2CL4 - State VW\V?, Zip .5S 30) ( Telephone#(9524 c4-1 13 COMPLETE THIS AREA ONLY IF CONSTRUCTING A NEW BUILDING Minnesota Rules 7670 Category 1 _ Minnesota Rules 7672 Energy Code Category • Residential Ventilation Category 1 Worksheet New Energy Code Worksheet (J submission type) Submitted Submitted • Energy Envelope Calculations Submitted in the IQS1 12 months, has the City of Eagan issued a permit for a similar plan based on a master plan? ,>1 Y N If yes, date and address of master plan: Licensed Plumber `fir c?nr V??s • Mechanical Contractor Eel, ?`''l ? CL Sewer/Water Contractor -) v Q1,` Telephone # (q? T `1V S {b `{ 2 Telephone #(?SZ? Yid 4bcji2- Telephone # NS24 f5M`4 y 149141 I hereby apply for a Residential Building Permit and acknowledge that the information is complete and accurate; that the work will be in conformance with the ordinances and codes of the City of Eagan and the State of MN Statutes; I understand this is not a permit, but only an application for a permit, and work is not to start without a permit; that the work will be in accordance with the approved plan in the case of work wh (? approval of plans. 101 T l N ? Il ,) p\,?h C7 I iv vc V C3 , Applicant's Printed Name Signature 1 7 2007 2007 "SIDENTIAL BUILDING PERMIT APPLICATION . City Of Eagan 3830 Pilot Knob Road, Eagan MN 55122 Telephone # 651-675-5675 FAX 9 651-675-5694 New construction Requirements 3 registered site surveys showing sq. ft. of lot, sq. ft. of house; and all roofed areas (20% maximum lot coverage allowed) 1 Soils Report if proposed building is to be placed on disturbed sal 2 copies of plan showing beam & window sizes; poured found design, etc. I set of Energy Calculations 3 copies of Tree Preservation Plan if lot platted after 711193 Rim Joist Detail options selection sheet (buildings with 3 or less units) Minnegasco mechanical ventilation form Remodel/Repair Requirements 2 copies of plan showing footings, beams, foists 1 set of Energy Calculations for heated additions 1 site survey for additions & decks Addition - indicate don-site septic system Telephone #( Plans are considered public information unless you state thev are trade secret and the reason. Date Site Address Construction Cost Unit/Ste # Description of Work Multi-Family Bldg _ Y _ N Fireplace(s) _ 0 - 1 - 2 Property Owner Telephone # ( ) Contractor Address State City Zip Telephone # ( ) COMPLETE THIS AREA ONLY IF CONSTRUCTING A NEW BUILDING - Minnesota Rules 7670 Category I _ Minnesota Rules 7672 Energy Code Category . Residential ventilation Category 1 Worksheet New Energy Code Worksheet (J submission type) Submitted Submitted •. Energy Envelope Calculations Submitted In the last 12 months, has the City of Eagan issued a permit for a similar plan based on a master plan? - Y. - N If yes, date and address of master plan: Licensed Plumber Mechanical Contractor Sewer/Water Contractor Telephone #( Office Use Only Cen of Survey Recd _Y _N Soils Report -Y -N Tree Pres Plan Recd _ Y _ N. Tree Pres Required _Y _N On-site Septic System _Y _N Telephone #( I I hereby apply for a Residential Building Permit and acknowledge that the information is complete and accurate; that the work will be in conformance with the ordinances 'and codes of the City of Eagan and the State of MN Statutes; I understand this is not a permit, but only an application for a permit, and work is not to start without a permit; that the work will be in accordance with the approved plan in the case of work which requires a review and approval of plans. Applicant's Printed Name • + Applicant's Signature DO NOT WRITE BELOW THIS LINE Sub Types ? 01 Foundation ? 07 05-plex ? 13 16-plex ? 20 Pool ? 30 Accessory Bldg 02 SF Dwelling ? 08 06-plex ? 16 Fireplace ? 21 Porch (3-sea.) ? 31 Ext Alt -Multi ? 03 01 of_ plex ? 09 07-plex ? 17 Garage ? 22 Porch/Addn. (4-sea.) ? 33 Ext Alt - SF ? 04 02-plex ? 10 08-plex ? 18 Deck ? 23 Porch (screen/gazebo/pergola) ? 36 Multi Misc. ? 05 03-plex ? 11 10-plex ? 19 Lower Level ? 24 Storm Damage ? 06 04-plex ? 12 12-plex ? 25 Miscellaneous Work T es 31 New ? 35 Int Improvement ? 38 Demolish Interior ? 44 Siding ? 32 Addition ? 36 Move Building ? 42 Demolish Foundation ? 45 Fire Repair ? 33 Alteration ? 37 Demolish Building' ? 43 Reroof ? 46 Windows/Doors ? 34 Replacement 'Demolition (Entire Bldg) - Give PCA handout to applicant Description: Water Damage _ Yes Valuation ?gS,lxfl Occupancy S 2C - I MCES System Plan Review !b 100%or 25% Census Code / D) Zoning PD City Water SAC Units f Stories 2 Booster Pump # of Units 1 Sq. Ft. Z 7 Z LD PRV # of Bldgs I Length 66 . Fire Sprinklered Type of Const Width Footings (new bldg) Footings (deck) Footings (addition) Id Foundation _ Drain Tile Roof wit lee&Water Final Framing j Fireplace _iZ R.I. _gAirTest ZdFinal LO Insulation h A. Approved Base Fee Surcharge Plan Review MC/ES SAC City SAC Utility Connection Charge S&W Permit & Surcharge Treatment Plant License Search Copies Other Total REQUIRED INSPECTIONS _ Sheetrock Final/C.O. _ Final/No C.O. _ HVAC Other Pool _ Ftgs _ Air/Gas Tests -Final Siding _ Stucco Lath -)4 Stone Lath -Brick Windows Retaining Wall Building Inspector eoyexep 5;bae 63 ,9.f,. x y5.0 o (0 AR4.1a4 OCy`D o°f9 ss•r4 x 33.68 unFcntsyea BASe.neht-/B 38s?•f*• x 15-5'0 7y7µ q Fl.p R l 8 S? --^-t - X X9.7 E? ?A9 r?oo2 I?L'1 S9•i`tx 79.7$ $3 qq, 61EYO . rz) P ' •A Permit # Permd Date REScheck Software Version 3.7.3 Compliance Certificate Project Title: Wakefield "C" - French Inventory Report Date 12/13107 Data filename. G:ICADVEI%TRADIT-11WAKEFI-1\C-FREN-11WAKEFI-1\FULLAN-1.RCK Energy Code: 2003 IECC Location' Eagan, Minnesota Construction Type Single Family Glazing Area Percentage 15% Heating Degree Days: 7981 Construction Site Owner/Agent: Designer/Contractor' 1708 Term Glenn Court Lennar Eagan, MN 545 Indian Mound East Wayzata, MN 952-249-4500 GompllencQ:Passes t`+ xi; Masiit»4mUAr689°,. Ypur:FiorrretlA.QOM,``k;;t1.T%BatterThan,CQde,(UAf` Ceiling 1. Flat Ceiling or Scissor Truss. 1971 44.0 00 53 Wall (egress): Wood Frame, 16" ox 83 19.0 0.0 3 Window 1: Wood Frame Double Pane with Low-E' 32 0.330 11 Wall 2: Wood Frame, 16" o c 1983 190 0.0 94 Window 2: Wood Frame Double Pane with Low-E 373 0 330 123 Door 1: Solid: 38 0.067 3 Wall 3: Wood Frame, 16" o.c.' 1452 190 00 77 Window 3: Wood Frame Double Pane with Low-E. 166 0.330 55 Wall 4' Wood Frame, 24" o c' 188 0.0 6.5 24 Wall 5: Wood Frame, 24" o .c . 180 0.0 65 23 Basement Wall (egress) Solid Concrete or Masonry: 52 0.0 50 6 Basement Wall (full). Solid Concrete or Masonry ' 1562 0.0 50 125 Floor 2. All-Wood Joist(fruss.Over Outside Air. 48 24.0 00 2 Floor 3: All-Wood Joist/Truss:Over Unconditioned Space: 84 44.0 00 2 Furnace 1: Forced Hot Air. 90 AFUE Compliance Sfafement The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2003 IECC requirements in REScheck Version 3.7.3 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. Builder/Designer Company Name Date Project Notes. 9' Full Foundation Wakefield "C" - French Inventory Page 1 of 1 _? . City-Inspection-Dept-Copy City Forester Copy Applicant/Builder Copy Development ?L ?? (flN N Zw'ta? Lot Number Block Number 3 Address Builder WN (71'1\) t3 (A CCQl TN Phone Number: Tree Protection Requirements: Tree Protection Fencing Installed On Site Oak Tree Pruning (Im mod lately seal wounds during April 1 to July 31) y ( Therapeutic Pruning Required Retaining Wall To Be Installed Other: Replacement Trees Not Required _ „_._....• -•°°°"'"'•....•?.-Y DIVI$?ON I As Follows: EAGAN FORESTRY D'V'S'ON Attachments: r REVIEWED _ Yes BY No DATE Additional Notes: H. \ghove\2006fileWeepres\Tree Preservation Plan Summap-2006 (BUILDER, PLEASE READ ATTACHMENTS) 1708 TERRA GLENN COURT CERTIFICATE OF SURVEY For: LUNDGREN BROS. of 6 Block 3 Pre House Proposed Post House TERRA GLENN 2ND ADDITION Development Const. Tree Preservation Constructio Tree Preservation plan Const. As-Built Post House Const. As-Built OINT NO. LEV. YPE IA w > u¢i (D O (/1 v > O :2 Of z cn w a w o w Z O w > coil p cn v > O :5 z F_ N w w Z O z x nea z x 1789 873.9 MAPI IF 2 x x 1790 872.9 OAK z x x x 1791 2" 1 x x x 17 z x x x 1793 8134.6 SPRUCE 2 x x 1794 386.5 SPRUCE z x x x 1795 882.9 SPRUCE 2 X X X 1796 888.1 SPRUCE 2 x x X 1797 888.8 SPRUCE 3 x x X ' 8873 SPRUCE z x x x r7 ?9 8900 PIN 1 x x x 6o 88315 SPRUCE z x x x 1 1 1 SPRUCE 2 x x x ASH 3 X X IRM 8900 AK 2 X X 11 APPIF 2 X X X iRnS 8844 PINE 2 X X X z x x x 7 8921 SPRUCE 2 X 889.0 SPRUCE z A x x 1809 884j 2 X X 1810 8874 SPRUCE x 1849 395.1 LINDEN 2 X X 1850 8946 PINE 3 x x X 18 INDEN X 1854 8909 H RY 2 X X 891.9 PINE 1 X X X 1855 893.6 PINE 2 X x x 1 57 894.9 MAPLE X X 8943 PINE 1 - X X 1 X X 8 3 X x 1861 8921 ASH X X 81962 PINE 3 X X 04 8903 M 4 X X X M 12 14 X X Preliminary Tree Certification During a site visit on November 1, 2007, all significant trees designated to be saved on the Tree Preservation Plan prepared by James R. Hill, Inc., were present and in good health, except as noted in the table above. ?olw-O? ?QJ? Date: /l-/o'b7 BY By. John L. Benner, Minnesota L.S. No, 26708 Signature of Owner Date: ri 0 zL 0 11 Scale: i"=30' Page 2 of 2 James R. Hill, Inc. LOT SURVEY CHECKLIST FOR RESIDENTIAL PLICATION BUILDING PERMIT A P I II PROPERTYLEGAL: ?t)r b %1'cI 3 -r*'rR-??enY% J?dd DATE OF SURVEY: LATEST REVISION: m c A t U_ Q p Z ? Q DOCUMENT STANDARDS ? ? . Registered Land Surveyor signature and company ? ? • Building Permit Applicant r? ? ? . Legal description /? ? ? • Address g ? ? . North arrow and scale ? ? • House type (rambler, walkout, split w/o, split entry, lookout, etc.) J2 ? ? • Directional drainage arrows with slope/gradient % ? ? • Proposed/existing sewer and water services & invert elevation 'f ? ? . Street name ? ? . Driveway (grade & width - in R/W and back of curb, 22' max.) ? ? . Lot Square Footage g ? ? . Lot Coverage ELEVATIONS Existing ? ? . Property corners 0 ? ? • Top of curb at the driveway and property line extensions y7 ? ? • Elevations of any existing adjacent homes ? 7 ? . Adequate footing depth of structures due to adjacent utility trenches ? "d ? • Waterways (pond, stream, etc.) Proposed ? ? Garage floor ?' ? ? Basement floor ? ? Lowest exposed elevation (walkout/window) ,g ? ? . Property corners ? ? . Front and rear of home at the foundation PONDING AREA (if applicable) ? Jd ? • Easement line ? ? . NWL ? ? . HWL ? 2 ? . Pond # designation ? ? . Emergency Overflow Elevation ? z • Pond/Wetland buffer delineation Y ' • Shoreland Zoning Overlay District Y • Conservation Easements DIMENSIONS ,H ? ? • Lot lines/Bearings & dimensions A4 ? "Yf . Right-of-way and street width (to back of curb) SLOW f c-di ks d;f4f ?s; tin f° 1>4k - ? 'Pl • Proposed home dimensions including any proposed decks, overhangs greater than 2', porches, etc. 5614 14m? li mS, (i.e. all structures requiring permanent footings) rg.sP kb-// dots A00 SeoJL ? 34.21 - SC.a.ft1 +o4oI +? {r/{t;?j, ; f ? ? . Show all easements of record and any City utilities within those easements corru.-F? ? ? • Setbacks of proposed struct:114 k of adjacent existing structures ,g ? ? Retaining wall requirements: / Reviewed By: Date /Zh8! 07 Iz1Z?/o7 G:lFORMSBuilding Permit Application Rev. 11-26-04 rartiii 17t1CS?3doo nr=m+ 890.9 w A Denotes set spike O Denotes set iron monument • Denotes found iron monument x927.6 Denotes existing elevation (930.0) Denotes proposed elevation X [851.2] Denotes as-built elevation Denotes rear of building pod Denotes proposed drainage TC Denotes top of curb Bench Mark: 863.51 -Lots 4 & 5. Block 3 Proposed Garage Floor= 865. 2 Proposed Garage Top of Block= 865. 6 Proposed House Top of Block= 865. 6 Proposed Lowest Floor= 856. 9 Proposed Top of Block at Egress Window= 860.1 864.9 N ? o' v: I /1 T 864.2 L.U I ?864. 1 O„ E ' ?g6z.? N? ?68?4 g64?4.8 g6 5i33 ?/? / S 4\0j Bw l ?? b ?0 d.7 ?... - ? + o?F f9 a 101 DATE J 66't BUILDING INSPECTIONS DIVIWAI LOT 6' \ d ? AFPO9'P ?8s cP9o,?l c? WED C A &I Maximum Slopes or Retaining Wall Will Be Required J ?#a imp m D n o= I MWD 0 om ; ca J Ql ,0 N / 0 \ No n? q J,T 00 I By 9 ? ?- Date Z 2 ti EXISTING r EAGAN ENG G DBP1: RETAINING WALL / Io `,? DRAINAGE & UTILITY = /s L_- EASEMENT PER PLAT _N' o i M 75,ov /(0o5,0) ?N TERRA GLENN COURT For: PROP Lot 6 2ND f OR SOD i 00 N s6., N X0-9 - I OF LOT 6 = 43,179 SQ. FT. PROPOSED HOUSE =2,738 SQ. FT 6.37 OF LOT AREA T -7 L-v I DRIVEWAY = 894 SQ. FT. SAN. SERVICE INVERT CoWRo`ELEV'-850.0 223.99 SPX IT EXISTING PERMIT City of Eagan Permit Type:Building Permit Number:EA126551 Date Issued:08/29/2014 Permit Category:ePermit Site Address: 1708 Terra Glenn Ct Lot:6 Block: 3 Addition: Terra Glenn 2nd PID:10-75401-03-060 Use: Description: Sub Type:Reroof Work Type:Replace Description: Census Code:434 - Zoning: Square Feet:0 Occupancy: Construction Type: Comments:Please print pictures of ice and water protection and leave on site. Carbon monoxide detectors are required by law in ALL single family homes . Robert Day Valuation: 4,000.00 Fee Summary:BL - Base Fee $4K $103.25 0801.4085 Surcharge - Based on Valuation $4K $2.00 9001.2195 $105.25 Total: I hereby acknowledge that I have read this application and state that the information is correct and agree to comply with all applicable State of Minnesota Statutes and City of Eagan Ordinances. Contractor:Owner:- Applicant - Anthony C Phelps 1708 Terra Glenn Ct Eagan MN 55122 (952) 297-6928 Prohome Services Llc 13482 Martin St NW Andover MN 55304 (763) 205-2678 Applicant/Permitee: Signature Issued By: Signature PERMIT City of Eagan Permit Type:Building Permit Number:EA138997 Date Issued:10/04/2016 Permit Category:ePermit Site Address: 1708 Terra Glenn Ct Lot:6 Block: 3 Addition: Terra Glenn 2nd PID:10-75401-03-060 Use: Description: Sub Type:Siding Work Type:Replace Description: Census Code:434 - Zoning: Square Feet:0 Occupancy: Construction Type: Comments:Please leave printed pictures of house wrap on site for the final inspection. When installing ventilated soffit material, remove existing material (i.e. debris that could block vents) and take steps to ensure maximum ventilation to attic. Call for final inspection after installation. Valuation: 4,000.00 Fee Summary:BL - Base Fee $4K $103.25 0801.4085 Surcharge - Based on Valuation $4K $2.00 9001.2195 $105.25 Total: I hereby acknowledge that I have read this application and state that the information is correct and agree to comply with all applicable State of Minnesota Statutes and City of Eagan Ordinances. Contractor:Owner:- Applicant - Anthony C Phelps 1708 Terra Glenn Ct Eagan MN 55122 (952) 297-6928 Austad Construction 182 A Ryan Ln Little Canada MN 55117 (913) 651-4820 X070 Applicant/Permitee: Signature Issued By: Signature PERMIT City of Eagan Permit Type:Building Permit Number:EA149654 Date Issued:06/04/2018 Permit Category:ePermit Site Address: 1708 Terra Glenn Ct Lot:6 Block: 3 Addition: Terra Glenn 2nd PID:10-75401-03-060 Use: Description: Sub Type:Reroof Work Type:Replace Description:Does not include skylight(s) Census Code:434 - Residential Additions, Alterations Zoning: Square Feet:0 Occupancy: Construction Type: Comments:Please print pictures of ice and water protection and leave on site. Carbon monoxide detectors are required within 10 feet of all sleeping room openings in residential homes (Minnesota State Building Code). Valuation: 4,000.00 Fee Summary:BL - Base Fee $4K $103.25 0801.4085 Surcharge - Based on Valuation $4K $2.00 9001.2195 $105.25 Total: I hereby acknowledge that I have read this application and state that the information is correct and agree to comply with all applicable State of Minnesota Statutes and City of Eagan Ordinances. Contractor:Owner:- Applicant - Anthony C Phelps 1708 Terra Glenn Ct Eagan MN 55122 Gold Star Contracting 2124 Swallowtail Dr. Shakopee MN 55379 (612) 221-4553 Applicant/Permitee: Signature Issued By: Signature L D �TT� T .9 JC�1 V For Office Use ! E AGA N APR 16 2019 Permit#: ISS 11, Permit Fee: Date Received: I (c t I 3830 PILOT KNOB ROAD I EAGAN, MN 55122-1810 (651)675-5675 I TDD: (651)454-8535 I FAX:(651)675-5694 Staff: buildinginspections a cityofeagan.com 2019 RESIDENTIAL BUILDING PERMIT APPLICATION Date: V/</10 Site Address: 1708 74:0-"ra C/pi' (c -rT 4‹,6447 Unit#: Name: �i'/''% 610601 Phone: Resident/ / Owner Address/City/Zip: 170(.1 ✓r Kmac? 66/ellCC.-01/d-f/2er,pa j /2-7it/ f 4.22 Applicant is: Owner / Contractor Type of Work Description of work: rr-)•S/) geo,SP Construction Cost: Multi-Family Building:(Yes ' � /No I ) Company: 74/114.5/-,-. m t,? ' r or /-tx Contact: �0///4" Contractor Address: 3/8 7 ijr v,; 4 e/,/, C.), A/ City:,i d oA Jj#Y7 / cti State: MPZip: 5 5.917_3 Phone: 6/1.1/3d-,r//c/ Email: 0..41., ••0..41., ••,/,�' License#: U 7Z/63517 Lead Certificate#: v:7(Y9-II-0007 If the pro'ect is exempt from lead certification, please explain why: ' 4 7 - /dyi Cid COMPLETE THIS AREA ONLY IF CONSTRUCTING A NEW BUILDING In the last 12 months,has the City of Eagan issued a permit for a similar plan based on a master plan? Yes No If yes,date and address of master plan: Licensed Plumber: Phone: Mechanical Contractor: Phone: Sewer&Water Contractor: Phone: Fire Suppression Contractor: Phone: NOTE:Plans and supporting documents that you submit are considered to be public information. Portions of the information may be classified as non-pubiic if you provide specific reasons that would permit the City to conclude that they are trade secrets. You may subscribe to receive an electronic notification from the City of proposed ordinances by signing up for an email update on the Citys website at www.citvofeagan.com/subscribe. Exterior work authorized by a building permit issued in accordance with the Minnesota State Building Code must be completed within 180 days of permit issuance. CALL BEFORE YOU DIG. Call Gopher State One Call at(651)454-0002 for protection against underground utility damage. Call 48 hours before you intend to dig to receive locates of underground utilities. www.nogherstateonecall.orq I hereby acknowledge that this information is complete and accurate;that the work will be in conformance with the ordinances and codes of the City of Eagan; that I understand this is not a permit, but only an application for a permit, and work is not to start without a permit; that the work will be in accordance with the approved plan in the case of work which requires a review and approval of plans. x N/ r- PT/�r x „ � App. an`tys Printed e A r tur DO NOT WRITE BELOW THIS LINE 1 -7 0 re W2� 61Eilil Ch / oo '-- .SUB TYPES Foundation — Fireplace _ Porch(3-Season) _ Exterior Alteration(Single Family) Single Family _ Garage _ Porch(4-Season) _ Exterior Alteration(Multi) — Multi _ Deck _ Porch(Screen/Gazebo/Pergola) _ Miscellaneous _ 01 •of Plex ••74 Lower Level _ Pool Accessory Building WORK TYPES / New _ Interior Improvement _ Siding _ Demolish Building* _ Addition Move Building Reroof Demolish Interior Alteration _ Fire Repair _ Windows _ Demolish Foundation Replace _ Repair Egress Window Water Damage Retaining Wall *Demolition of entire building-give PCA handout to applicant DESCRIPTION Valuation Occupancy t,(f it MCES System Plan Review Code Edition li a I( SAC Units (25%_100% 1,) Zoning A I City Water Census Code Stories Booster Pump #of Units Square Feet PRV #of Buildings Length Fire Suppression Required Type of Construction *f Width REQUIRED INSPECTIONS Footings(New Building) Meter Size: Footings(Deck) Final I C.O. Required Footings(Addition) Final I No C.O. Required Foundation — Foundation Before Backfill HVAC Service Test Gas Line Air Test Hood Roof:_Ice&Water _Final Pool:_Footings Air/Gas Tests _Final t Framing l 30 Minutes 1 Hour Drain Tile Fireplace:_Rough In _Air Test Final Siding:_Stucco Lath _Stone Lath Brick_EFIS Insulation Windows Sheathing Retaining Wall:_Footings_Backfill_Final Sheetrock Radon Control Fire Walls Fire Suppression:_Rough In_Final Braced Walls Erosion Control Shower Pan Other: �y eviewed By: /� , Building Inspectr, 1 1' RESIDENTIAL FEES (1)0 Base Fee Surcharge Plan Review MCES SAC City SAC Utility Connection Charge q 76 \n- 0 .../ ) 7 5 19 v S&W Permit&Surcharge ( Treatment Plant Radio Meter Read Copies TOTAL Page 2 of 3 r For Office Use ' ::::e: l Q(/t r�/ Date Received: �1 ,30 I 1 3830 PILOT KNOB ROAD I EAGAN, MN 55122-1810 (651)675-5675 I TDD: (651)454-8535 I FAX: (651)675-5694 Staff: buildinoinspectionsAcitvofeagan.com 2019 RESIDENTIAL PLUMBINGPERMIT APPLICATION Date: 00/20 1/ Site Address: I -70 $ fiE2+' G- -Er Cauit-r Tenant: Suite#: Resident/OwnerName: 2`(Y C r-C- V) Phone: Address/City/Zip: 171 ✓L- Name: Ph i•//, 75 001-).1b/ License#: P C qt 2I/S B 22-SB" V).S Contractor Address: �D UPJ 2 City: R State: /7 '7 Zip: -6533 7 Phone: /Z Gyy Zf Contact: be/ii>4 PLt 1 LG/P - ' Email: /01"/41.1p10 r1.1i n �nC, ct i -ii i I , Type of Work New _Replacement _Repair _Rebuild _Modify Space _Work in R.O.W. Description of work: Water Heater Lawn Irrigation( RPZ/_PVB) Water Softener DescriptionAdd Plumbing Fixtures( Main/.Lower Level) Septic System Description: 5'A0W y /Gr t/I Mde, �a✓ S/u �` New Abandonment Connection to City Water from Well RESIDENTIAL FEES $60.00 Water Heater, Water Softener, or Water Heater and Softener(includes State Surcharge) $60.00 Lawn Irrigation (includes State Surcharge) $60.00 New fixtures, adding or removing piping (includes State Surcharge) $60.00 Septic System Abandonment $100.00 New Residential (fee collected with Building Permit) $115.00 New Septic System (includes County fee and State Surcharge) $60.00 Connecting to City Water from Well*+$290 for Meter and $190 for Radio Read = $540 *Sewer&Water Permit also required for connection charges TOTAL FEES $ CALL BEFORE YOU DIG. Call Gopher State One Call at(651)454-0002 for protection against underground utility damage. Call 48 hours before you intend to dig to receive locates of underground utilities. www.qopherstateonecall.orq You may subscribe to receive an electronic notification from the City of proposed ordinances by signing up for an email update on the City's website at www.citvofeagan.com/subscribe. I hereby acknowledge that this information is complete and accurate; that the work will be in conformance with the ordinances and codes of the City of Eagan; that I understand this is not a permit, but only an application for a permit, and work is not to sta without a permit; that the work will be in accordance with the approved plan in the case of work which requires a review and approval plans. x t) ?k/Lam/ x ./21171744d16 Applicant's Printed Name Applicant's SignIMM Page 1 of 2 PERMIT City of Eagan Permit Type:Plumbing Permit Number:EA161765 Date Issued:06/11/2020 Permit Category:ePermit Site Address: 1708 Terra Glenn Ct Lot:6 Block: 3 Addition: Terra Glenn 2nd PID:10-75401-03-060 Use: Description: Sub Type:Residential Work Type:Replace Description:Water Softener Meter Size Meter Type Manufacturer Serial Number Remote Number Line Size Comments:Please call Building Inspections at (651) 675-5675 to schedule a final inspection. Allow an 18" minimum radius clearance to the water meter from all appliances (i.e. furnace, water heater, water softener). Fee Summary:PL - Permit Fee (WS &/or WH)$59.00 0801.4087 Surcharge-Fixed $1.00 9001.2195 $60.00 Total: I hereby acknowledge that I have read this application and state that the information is correct and agree to comply with all applicable State of Minnesota Statutes and City of Eagan Ordinances. Contractor:Owner:- Applicant - Derrick L Green 1708 Terra Glenn Ct Eagan MN 55122 Dakota Water Treatment 17484 Goodland Path Lakeville MN 55044 (952) 953-4643 Applicant/Permitee: Signature Issued By: Signature PERMIT City of Eagan Permit Type:Plumbing Permit Number:EA179279 Date Issued:09/27/2022 Permit Category:ePermit Site Address: 1708 Terra Glenn Ct Lot:6 Block: 3 Addition: Terra Glenn 2nd PID:10-75401-03-060 Use: Description: Sub Type:Water Heater Work Type:Replace Description:Tankless Water Heater Meter Size Meter Type Manufacturer Serial Number Remote Number Line Size Comments:Carbon monoxide detectors are required within 10 feet of all sleeping room openings in residential homes (Minnesota State Building Code). Please call Building Inspections at (651) 675-5675 to schedule a final inspection. Fee Summary:PL - Permit Fee (WS &/or WH)$59.00 0801.4087 Surcharge-Fixed $1.00 9001.2195 $60.00 Total: This permit shall be null and void if work does not start within 180 days of issuance, or if work is suspended for 180 days or more after started. I hereby acknowledge that I have read this application and state that the information is correct and agree to comply with all applicable State of Minnesota Statutes and City of Eagan Ordinances. Contractor:Owner:- Applicant - Derrick L Green 1708 Terra Glenn Ct Eagan MN 55122 (205) 296-5196 Dean's Home Services 6701 Parkway Circle Suite 600 Brooklyn Center MN 55430 (763) 428-1321 Applicant/Permitee: Signature Issued By: Signature