1345 Towerview Rdy Al (Urtifiratt of (Orrupaury citp of (Eagan a,epartwnd of biag attnn This Certificate issued pursuant to the requirements of Section 306 of the Uniform Building Code certifying that at the time of issuance this structure was in compliance with the warlous ordinances of the City regulating building construction or use. For the following: U.a..ot SF DWG/GAR etas. %.it N.. 16580 O-r•-r T* R3/M 1 Zonis Di.trict Type cons. VN OWnrofB,,;a;JOBBY %W= Add= 3911 VMM VIM, EWAN ftUng AA&m 1345 1C WER9M FM Lmlity L4. B2, IDW LA14E HMM z : %Y 2, Dw: 0GrDM 192 1989 morns Offcwx, POST IN A CONSPICUOUS PLACE r1 DATE: 6/6189 RE:1345 TOWERVIEW ROAD, L4. B2, LEMAY LAKE HILLS Kx Your Sever & Water Permit for the above property has been completed. It will be held at the Public W s Garage (3501 Coachman Road) until the meter is picked up. BE SURE TO CALL PUBLIC WORKS (454-5220) FOR YOUR PERMANENT WATER TURN ON. Your Sewer & Water Permit for the above property cannot be completed for the following reasons: M Your Sewer & Water Permit for the above property has been completed, but the meter cannot be Issued 2' occupancy allowed until further notice. COMMERCIAL PROJECTS ONLY: Please pay for meter at City Hall. Meter size must be confirmed by Bill Adams or Dirk House (Plumbing Inspectors - 454-8100) before issuance. WARNING: BEFORE DIGGING, CALL LOCAL UTILITIES - TELEPHONE, ELECTRIC, GAS, ETC. - REQUIRED BY LAW. CONTACT COMMUNITY DEVELOPMENT DEPARTIOENT FOR WATER TURN ON POLICY. Secretary, Building Inspections Dept. DATE: 6/6/89 RE- 1345 TOWERVIEW ROAD. L4. E2, LEMAY LAKE H1LLS XX Your Sewer & Water Permit for the above property has been completed. It will be held at the Public Works Garage (3501 Coachman Road) until the meter is picked up. BE SURE TO CALL gi11BLIC WORKS (4545220) FOR YOUR PERMANENT WATER TURN ON. Yo6r Sewer & Water Permit for the above property cannot be completed for the following reasons: Your Sewer & Water Permit for the above property has been completed, but the meter cannot be issued or occupancy allowed until further notice. COMMERCIAL PROJECTS ONLY: Please pay for meter at City Hall. Meter size must be confirmed by Bill Adams or Dirk House (Plumbing Inspectors - 454-8100) before issuance. WARNING: BEFORE DIGGING, CALL LOCAL UTILITIES - TELEPHONE, ELECTRIC, GAS, ETC. - REOUIRED BY LAW. CONTACT COMMUNITY DEVELOPMENT DEPARTMENT FOR WATER TURN ON POLICY. Secretary, Building Inspections Dept. CITY OF EAGAN j n 3830 Pilot Knob Road, P.O. Box 21-199, Eagan, MN 55121 PHONE: 454-8100 PERMIT r,L uc I GAR Est. Value $114,000 Receipt # OFFICE Occupancy USE ONLY FEES Zoning (Actual) Const - Bldg. Permit W. m (Allowable) Surcharge 57.00 N of Stories Length Plan Review 364.00 Depth SAC, City ! S.F. Total 575,00 ` S.F. Footprints SAC, MCWCC 56C.00 On Site Sewage Water Conn On Site Well Water Meter • MWCC System City Water X Atct. Deposit lf) .I PRV Required SNU Permit 2d . Or Booster Pump S/W Surcharge i Treatment PI APPROVALS Road Unit Planner Park Ded. Council Bldg. Off. Variance Copies TOTAL Lot Block y Sec/Sub. Parcel No. W Name LOBBY WARYIELD j Address '5! V A LLFY VI E W1 City NGAtd Phone 888-7197 c Name Address City Phone WW Name Address i W City Phone I hereby acknowlege that I have read this application and state that the information is correct and agree to comply with all applicable State of Minnesota Statutes and City of Eagan Ordinances. Signature of Permitee A Building Permit is issued to: DUBL t' VAP r I ELD on the express condition that all work shall be done in accordance with all applicable State of Minnesota Statutes and City of Eagan Ordinances. Building Official Permit No. Permit Holder Date Telephone # 'WATER z SEWER PLUMBING / 'f q H.V.A.C. 02. C ?iP ELECTRIC y 4/O3k J ' / p /`f 0 ?O Inspecum Date Insp. Comments Footings1 "N" Foundation Framing QS Roofing Rough PIbg. - Rough Htg. Q Isul. / S Fnoace g C ICIC vna e Q ,..a , f• Final Hip. / ale Final Plbg. 0 Cant. Meter Plbg. Inspector - Notify Plumber Engr./Ptan Bldg. Final 7 a Deck Fig. be& Final Well Pr. Disp. MECHANICAL PERMIT PERMIT # ' CITY OF EAGAN RECEIPT # 3830 PILOT KNOB ROAD, EAGAN, MN 55122 DATE: CONTRACT PRICE PHONE: 454-8100 For Office Use Only: Site Address BLDG. TYPE WORK DESCRIPTION Lot Block / u4 V Res. New I X_kA, 4L _ Name "?` ?• , , ,fir. Mutt Add-on G m Address Comm. Repair c City _,-'`• z Phone Other v E FEES •! Name RES. HVAC 0-100 M BTU -$24.00 Address <-, • %r"'I ADDITIONAL 50 M BTU 800 • *cv city; - Phone (RES. HVAC INCLUDES A/C ON NEW , 7 CONSTRUCTION) k GAS OUTLETS (MINIMUM 1 PER PERMIT 50 EA 1 - ) - . . TYPE OF WORK COMM/IND FEE - 1% OF CONTRACT FEE Forced Air ` M BTU ! c{ APT. BLDGS. - COMM. RATE APPLIES TOWNHOUSE & CONDOS - RES. RATE APPLIES Boiler M BTU MINIMUM RESIDENTIAL FEE - ALL ADD-ON 5 Unit Heater M BTU REMODELS - 12.00 Air Cond. M BTU MINIMUM COMMERCIAL FEE - 20.00 STATE SURCHARGE PER PERMIT - .50 Vent G P t # O CFM T (ADD $.50 S/C IF PERMIT PRICE GOES BEYOND $1 000) as iping lets u , Other FEE ' SIGNATURE OF PERMITTEE SIC: TOTAL ?' FOR: CITY OF EAGAN CONTRACT PRICE Site Address Add c City CITY OF EAGAN 3830 PILOT KNOB ROAD, EAGAN, MN 55122 PHONE 4548100 Phone FEES COMMAND. FEE -1% OF CONTRACT FEE APT. BLDGS. - COMM. RATE APPLIES TOWNHOUSE & CQNDO - RES. RATE APLLIES MINIMUM - RESIDENTIAL FEE $12.00 MINIMUM - COMM.IND.IFEE $20.00 STATE SURCHARGE PER PERMIT .50 (ADD $.50 SIC PER EACH $1,000 WERMIT FEE) Res. Mult. Comm. Other PERMIT # DATE: New Add-on Repair NO5 FIXTURES TOTAL Water Closet - $3.00 ?- $ Bath Tubs - $3.00 Lavatory - $3.00 ?- Shower - $3.00 -? Kitchen Sink - $3.00 Udnal/Bidet - $3.00 ?- Laundry Tray - $3.00 1 I Floor Drains - $1.50 - ? Water Heater - $1.50 Whirlpool - $3.00 ?- Gas Piping Cutlets - $1.50 (MINIMUM -1 PER PERMIT) Softener - $5.00 Well - $10.00 Private Disp. - $10.00 Rough Openings - $1.50 PERMIT FEE: STATES SIC: ,5U GRAND TOTAL: D U SEWER & WATER PERMIT CITY OF EAGAN 3830 Pilot Knob Rd. Eagan, MN 55122-1897 OFFICE USE ONLY METER #F !Y'l I " PERMIT DATE 616/89 CHIP #E 40? ! g 7 WATER PERMIT # 10488 METER SIZE A B.P. RECEIPT # C 2316 ISSUE DATE 20=f-19 B.P. RECEIPT DATE 616181) - PRV _ BOOSTER PUMP SITE ADDRESS ILL 1',."I V' i w at - PERMIT REQUESTED LOT ?BLOCK*12_SEC/SUB -4'_4=1 - SEWER TER -TAPS APPLICANT" L r J'' ADDRESS: 1 COMM/IND RESIDENTIAL CITY, STATE / - ?! r • ZIP PHONE: NEW _ EXISTING PLUMBER: ADDRESS: I AGREE TO COMPLY WITH CITY OF CITY, STATE ZIP EAGA ORDINANCES: r PHONE:., 1OWNER: s) c ADDRESS: I ^ SIGN WHEN METE ISSUED CITY, STATE F Ali ^ ZIP <5"LT Z PHONE: 7 \ PLEASE ALLOW TWO WORKING DAYS FOR PROCESSING. FOR STORM SEWER PERMITS, CONTACT 1 ENGINEERING DEPT. APPLICANT AND PLUMBER WILL BE NOTIFIED WHEN PERMIT IS PROCESSED. t ?? SEWER & WATER PERMIT CITY OF EAGAN 3830 Pilot Knob Rd. Eagan, MN 55122-1897 SITE LOT. APPLICANT!'. ADDRESS:- CITY, STATE PHONE: METER # OFFICE PERMIT DATE 6 / 6 / 89 WATER PERMIT #E 10488 B.P. RECEIPT # C 2316 B.P. RECEIPT DATE )/6/89 CHIP #E METER SIZE ISSUE DATE _ PRV -BOOSTER PUMP LJ ", V ' w K'Iy l PERMIT REQUESTED JB 4, Z/ /1; SEWER -J RATE R; - TAPS '? - COMMAND - RESIDENTIAL I ZIP - Z NEW - EXISTING PLUMBtR: STA L, 1 ADDRESS: - l c l y 11 L? I AGREE TO COMPLY WITH CITY OF CITY, STATE ZIP EAGAN,ORDINANCES: PHONE: 4 ? r %? / i G . OWNER: r ADDRESS: CITY, STATE ZIP PHONE: I `7 SIGNATURE WHEN METER ISSUED PLEASE ALLOW TWO WORKING DAYS FOR PROCESSING. FOR STORM SEWER PERMITS, CONTACT ENGINEERING DEPT. APPLICANT AND PLUMBER WILL BE NOTIFIED WHEN PERMIT IS PROCESSED. CITY OF EAGAN X830 Pilot Knob Road Eagan, Minnesota 55122-1897 (612) 681-4675 SITE ADDRESS: 1J 11?r s 1' ; iiwi rv i rw RCS tl;, F t tl I t I `• PERMIT SUBTYPE: PERMIT TYPE: Permit Number: Date Issued: arr--Wsf%7--n; APPLICANT: 4 HIOC TYPE OF WORK: Ivl 11 03 147 L?!ue + a ?'- s 1 r ---- - - - - - - - - - - - - I Rf MARVS: PLAN Rf;VTfWVIj BY ;Jill' V(11•k`. Permit Holder Date Telephone Y PLUMBING HVAC Inspection Date Insp. Comments FOOTINGS FOUND FRAMING ROOFING ROUGH PLUMBING PLBG AIR TEST ROUGH HEATING GAS SVC TEST INSUL GYP BOARD FIREPLACE FIREPLACE AIR TEST FINAL PLBG FINAL HTG ORSAT TEST BLDG FINAL DOMESTIC METER IRRIGATION METER FLUSH MAINS CONDUCTIVITY TEST HYDROSTATIC TEST BSMT R.I. BSMT FINAL DECK FTG DECK FINAL p n/rte/h y C,! 40385 Rer?uest Dat%? 1/Yt Fire No nspedion be ned? ? Ready Now Will Notify Inspector 0 yes ? No When Ready? licensed contractor ? owner hereby request inspection of above electrical work at: Job Address (Street, Box or Route No.) City Section No Township Name or No Range No County ^t Occupant (PRIM) ? Phone No. G Power SupP?ar r & 1 Atltlrass .(: , Electrical Contractor (Company Name) CNo Mailing Addre(Contractor Making Making Installation) : Audgnzed ignature (COnI? /Owner bng Instal n) Pi Number MINNESOTA STATE BOARD OF ELECTRICITY THIS INSPECTION REQUEST WILL NOT Odgge-Midway Bldg. - Room S473 BE ACCEPTED BY THE STATE BOARD 1821 Univenlty Ave., SL Paul, MN 55100 UNLESS PROPER INSPECTION FEE IS Phone J612) 602-0800 ENCLOSED F 40385 REQUEST FOR ELECTRICAL INSPECTION ? See msWCeons for completing this form on back of yellow copy X" Below Work Covered by This Request !. EB-00001-07 New Add Rep. Type of Building Appliances Wired Equipment Wired Home Range Temporary Service Duplex Water Heater Electric Heating Apt Building Dryer Other (Specify) Comm./Industrial Furnace Farm Air Conditioner Other (specify) Contrecto is Remarks Compute Inspection Fee Below: # Other Fee # Service Entrance Size Fee # Clrcuits/Feedem Fee Swimming Pool 0 to 200 Amps ? 13 0 to 100 Amps sZ - Transformers Above 200 _ Amps Abo _ Amps Signs Inspectors Use Only: r)? TOTAL Irrigation Booms a , Special Inspection V A larm/Communication Other Fee I, the Electrical Inspector, hereby Rough-In f k ^ /I-&,- certify that the above inspection has been made. Final Date ( 6-414 OFFICE USE ONLY This request void 18 months from CITY OF EAGAN N? 16580 3830 Pilot Knob Road, P.O. Box 21-199, Eagan, MN 55121 PHONE: 454-8100 BUILDING PERMIT SF DWG/GAR Est. Value $114,000 Site Address 1345 TOWERVIEW RD Lot 4 Block 2 Sec/Sub. LEMAY LAKE HILL Parcel No. Name BOBBY WARFIELD o Address 3911 VALLEY VIEW City EAGAN Phone 688-7197 Name _ Address City - Name _ Address City - Phone I hereby acknowlege that I have read this application and state that the information is correct and agree to comply with all applicable State of Minnesota Statutes and Civ?g (7 an rdi a e ce t Signature of Permi ee 1 r 1---? A Building Permit is issued to: BOBBY WARFIELD on the express condition that all work shall be done in accordance with all applicable State of Minnesota Statutes and City of Eagan Ordinances. Building Official r 1 Phone Receipt # Date JUNE 5 1g$2 OFFICE USE ONLY Occupancy R-3 M-1 FEES Zoning (Actual) Const V=N Bldg Permit 688.00 (Allowable) VVN Surcharge 57.00 # of Stories Length -6! Plan Review 344.00 Depth 60' SAC. City 100.00 S.F. Total SAC, MCWCC 575.00 S F. Footprints On Site Sewage Water Conn 580.00 On Site Well Water Meter 90.00 MWCC System XX XX Acct. Deposit 30-00 City Water PRV Required SW Permit 20.00 Booster Pump SiW Surcharge 1 . 00 Treatment of 228.00 APPROVALS Road Unit 340.00 Planner Park Dad. Council _ Bldg Off Copies Variance TOTAL 3,053.00 , 1989 BUILDING PERMIT APPLICATION CITY OF EAGAN SINGLE FAMILY DWELLINGS 2 SETS OF PLANS 3 REGISTERED SITE SURVEYS 1 SET OF ENERGY CALCS. MULTIPLE DWELLINGS RENTAL UNITS COMMERCIAL 2 SETS OF ARCHITECTURAL 6 STRUCTURAL PLANS 1 SET OF SPECIFICATIONS 1 SET OF ENERGY CALCS. FOR SALE UNITS # OF UNITS NOTEt ADDRESSES FOR CORNER LOTS - CONTRACTOR1HO14EOWNER MOST DESIGNATE WHICH ADDRESS IS DESIRED. NO CHANGES WILL BE ALLOWED ONCE BUILDING PERMIT IS ISSUED.. SEWER It WATER PERMIT FEES AND ACCOUNT DEPOSIT FEES WILL BE INCLUDED WITH THE BUILDING PERMIT FEE. PROCESSING TIME FOR SEWER AND WATER PERMITS IS TWO DAYS ONCE A PERMIT HAS BEEN COMPLETED INDICATING A LICENSED PLUMBER. PENALTY APPLIES MR: PERMIT IS NOT PAID FOR IN SAME MONTH IT IS REQUESTED. LOT CHANGE IS REQUESTED ONCE PERMIT IS ISSUED. To Be Used For: S'ns)t f" w Valuation:,61?-? Date: 5 -30- 89 Site Address 13 15 l ou er kh tu7 Cc? . Lot Block Z Parcel/Sub L-emAY LAKe H)u-J Owner _ ynhh?? Uar-O;OW Address `s I1 1h,14 J;e' IJ City/Zip Code Lip, SSIZZ Phone to kK- :7)9 -7 Contractor RA? i ao-r?;'d 19 Address 3x711 Ila& ?,YnZI rd, City/Zip Code ?aor.n M.1, s5/ZZ Phone 6 fS rr- 7 / 9 7 Arch./Engr. MdC. TewrinC kc,s Address A70 Ar ka-A sas Gk, City/Zip Code :C&otr- ?rnve ?k,s??S yLh. 10510 !&TLTIPLE DWELLINGS 2 SETS OF PLANS REGISTERED SITE SURVEYS - (CHECK WITH BLDG DIV.) 1 SET OF ENERGY CALCS. i/q,OFFICE USE Occupancy K-3 M_1 Zoning Actual Const V- N Allowable VV-N # of stories Length _T Depth (00 S.F. Total Footprint S.F. On site sewage On site well MWCC System v City water v PRV required Booster Pump _ APPROVALS Planner _ Council Bldg. Off. Variance Bldg. Permit 688,CV Surcharge r 00 Plan Review ?I,00 SAC, City !00,00 SAC, MWCC 5 O a Water Conn .688,00 Water Meter O 00 Acct. Deposi t O O O S/W Permit 20,00 S/W Surcharge 1,00 Treatment Pl . 00 Road Unit O,OO '7? 44 Park Ded. Copies SUBTOTAL Penalty TOTAL Phone # x/52-1999, Q14 ,.•srioN52 ",( 1723- O73LI - 7ooD 1?n:?t?ns VALUAi IDN GARAGE ter?ggrnj?- 4. x? (2ox a4= y45a 1.• IOX22= z2o ?02? Xa? = Zo 3n ? 'BSrn a4 XS0= 17-00 ZX zo= y.D ?2xn?z= 139 1 37 if x)y = 19 92 H, l'sMT - 13 5 I??Z??nP 15 Iy'64 XS?:. ?yZoo 113_.?-- m N Nt?°1532 VJ l i ?O 9° O 3 u z + j _ e o z.. c N R 0 S'0 71 :0 aP1,f?3 DRA O'I INAGE ? A /BS 7 a Go 16 Z4 Z4 ? ? ? ? m o g, ,,.t u , e f , m i? g ,ru..a N / y ^ JJ i 'o i \o?P / .C CA I 1.4 to / N ^ I"I V los 'o b VI e. 0 D2AINAGE ANO N A_ ? ? 7 S O? ^ ? fl c ? ao r e 163.IZ . 1 L I ? , ?. Ty 1? E / ? N o'tS' 3z:' W A sE _ / N /Z 0 v W D m ? rn L ? D u o ? w T 0 o ? $ a j 3 I hereby certify that this is a correct representation of a survey of: Lot 4, Black 1, LEMAY LAYS HILLS, Dakota County, Minnesota, according to the recorded plat thereof. and that this survey and certificate was prepared by ma or under my direct supervision and that I am a duly registered land surveyor under the lave of the State of Minnesota. . Jacoba PI Reg'. No. 7734 Dated this 30th day of May, 1989 Elevation, shown are existing grades and are city datum. Arrows denote proposed direction of surface water runoff. Proposed tap of foundation a 909.8 Proposed garage floor w 909.5 Proposed lowest floor w 901.0 Proposed finished grade at garage corners and front of house v 909.1 Proposed finished grade at rear of house 900.3 Bauder and or owner to verify all prnposed grades and grade the lot so that the surface water does not pond or create drainage problems for this lot or adjoining lots. i R IEW By r Da e 3 EAGAN ENGINEERIN DEP I ' CERTIFICATE OF SURVEY PREPARED FOR: I Todd Phillips Box 13314 Minneapolis, MI 55414 JACOBSON SURVEYORS LAKEVILLE, MN 55044 TEL. 469-4328 DR. BY G L J GATE MAY 'BO, 1989 „ 17-4-4 a II'W%J L_IdI%j U jm 1 14E.AT LOSS 'C.1_CULATIONS DEPARTMM"17 Of BUILDINGS Wcalherltrips A.GuidL Construction No. nsu 1 lo`n Guido MEZ .lows Doors Re Icrenee f)ul. Wall Isl. Wall _Ceding 19__ Rouf _ floor hind_ I low Applied /? -Nn 1'No ?J.__ _ Room I Lengt1ily p' 1lcight FLT „J Rani I L.eugth ?e?eSidth irlaght Windu\ and Uoon-Cleo kage and Area Windows and Doors-Crackag_c and At et _- 1\'1.111+ IIr.IKlil Nor If I.II+r I (l. Ar_rx ? \\'I II1+ Ilrllt l-l- M1u, ul I.I ri i.? I II Alr.u I I+_+x? I_I I.^I xr lil:l?l• rrf rllr• II nil fl Nn of Vn n! IIFLIn 111 ul r xrN I1` p II. :TI_ ta? 'y 1 -1 clef. Btll ?hralion ? 'G u 113, ;L p. wall t cxp. wall wall ding - /? ,or ,al Blu. / ?i?f.GC suited sq. ft. E.D.R. or sq. ins. W.A. Loader area ii in I Length /a ?-?'Widlll As Yindows and Doors-Crackaue and Arc ' W lplIn of V+r+n 11,10t of Dx+ N.. Df IIY hI< l.lurel ll. uI rrucN A,u •V. fl. 3 a _ / -? I _ Cne(. Btu lration Is H O 1 wall . exp. wall /r ll wa _ ? ?tllg 1 r ? /? L1_? SL 7S'" 11 Btu. oiled sq. ft. E.D.R. or sq. ins. W.A. Leader area ?,? ? Roorn Length Width// 4indows and Doors-Crackage and Area \Vldlk Vf pane 11<Ix ht pf pen. No. or lxhle LIn<al ft. .1 creek Ar<n ul. It. a v 2<-1- /7 tration ,s wall cxp. wall wall Ig I"*'- Coef.1 Btu I' _- d Btu. aired au. fl. L.D.R. or su. ins. W.A. Fader ate. Cocf.l Btu I nft II ra t inn J - - - Glass ----- Exp. wall '------ - Net exp. wall -------- - --- Int, wall -----?_-- ceiling Floor Total Btu. ?L :quired sq. ft. E.D.R. or sq. ins. W.A. Leader area EI.?Qs/¢3 Roo1rlILength / "Width Windows and Door s-Craeka ac and Area I N.. 1V Ia 111 of Verse IIe1Kht of Vane Nu of 1111111 Llwxl fl 0 rock Arun eV n. 7 Co<L Btu Infiltration _ 110 5yo Glass ./' (/6 a4 wall Ex - p. 1714 Net cxp. wall 77 _ ? 555 Int. Wall ceding - An 34 7?-^ . floor _ Dotal Btu. Required .q. ft. E.D.R. or sq. ins. W.A. Lcadcr aloe Fl.l Room I Length 1-leight Windows and Door:r Crackage and Area - tVlalh ItelYht Nn. of LInnll it, Are• N.. yf Dene of pane Ilalnl of cock 1y 1'1. _ Coef. Btu Infiltration Glean Exp. wall _ 71 mo (G -2 01 Net exp. wall Int. wall Ceiling I loar --?-?- lotal Btu. W _ Required sq. ft. L.U.R. or sq.ins. W.A. Uarkr area /? 5 ?.r.s-'-'"-rrtyV•?.?1 VJ. V 1 i _HEAT LOSS CALCUTA'fIONS DI=PARTMENT OF BUILDW ! 1 Construumn No. Wrpthns rin A GuideL rfRIIl, on rclows Doors IZeierence Out. Wall Ito. Wall Ceding Roof Floor -F:ind_ I low Applied --- .-No YesNo Iq_- '--- - ----- - -- _-? - - ==I -- I_I.? Rooln Length / Width 2://1 icighl -t--_ ?s hLf?l? Roma I Lrngdl id111 Tye I Icight S71' Windows and Doors-Crackagr and Area Windows and Doors---Crack,gc and Alca Ai ---- ? \\'Llln Ilriq Ll No u! Llurul !1_F_ . An'n f 1•n Yr ..I 1'•rru' LFlil+ n(i ru. Ir nil 11, Nn cif I'.rn^ n! H`e'r IINL(n ul rr xr_ n•I II. •? mac? <,z ? _3?. y -I - -1 `? ?? _1- _tl? 39-- -- - C_.ef. Bt 1. - /- _ c.'f l-I?11 (rllralmll ?/r ?/? /?j Yf I wall pv t exp. wall . . wall .S' ?7Ciq d?- dulg ? Ur l Btu. :,uircd sq. It. E.D.R. or sq. ins. W.A. Leader area -* ' ? a rSQ oorn I Length G idlll '?Bldcighl s ? r W indows a nd Doors -Cracka ge and Ar ea w'hllh Y( h•I ern IIelNlrl Y( ygnn NY.YI nelll• LI7,111E pr CrBCII Alex Q. 11, ? z 7 L Caef. Btu .lration _ f b ya is ?. ?c :. wall up. wall wall )9L9LA - 'f - --P??- ng Al Btu. -?-- luircd sq. ft. E.D.R. or sq. ins. W.A. Leader area / !. Room Length / ? idlhG2 d Height / / 7A f/indows and Doors-Crackage and Area Wldlh W Vana 1l ale hl or yxnn NY of Ighlq Llnenl N. oI crxck Arta nV. IL 3 G/' f. Qtu .lsalion ss wall a e exp. wall wall ing ? 20 ,r 'Al 11111. cited sq, ft. E.D.R. or Q. ins. W.A. L,radcr area I nfl It r at ion Glass c?(J Exp. wall ----- -? -?- - _ - L2%. Net exp. wall ------- //7e-1/- 0 Int. wall Id 9- ceiling floor Total Btu. Required sq. ft. E.D.R. or sq. ins. W.A. Leader arca FLIP ,&,y Room I Length S w Width Fleighl Q Windows and Doors-Crackage and Area \Vi. 111 II nINhI No YI Llnenl (1 Area No oI y.nn O( yxnn 11(ILL• of a'Ixfh en It. j Infiltration Class 7 0 ?6 ? Eap. wall ZML - _ Net exp. wall / gO? wall Int . ceilin g Flom 21 Total Btu. Required sq. ft. E.D.R. or 57. ins. W.A. Leader arca ] F1.1 Room I Length Width I'leiglu Windows and Doors-Cruckage and Area Na. l5'Idllr Yf yxnn it rlYM of pwa N7 n! IlNhlx 1.17...1 n oI cncM I are. o fl. Coe I. Btu Infiltration Glass Exp. wall Net exp. wall Int. wall - Criling I IUnr Total Btu. Required sq. ft. C.D.R. or sq. ms. W.A. Ieadr are. r "'TTY OF ?A,3AN -AF4IERz i -r , t'c Drw'Ifi? r_ inR T? In -. 'w, ? 1/.' Ira PERMIT CITY OF EAGAN 3830 Pik; Knob Road Eagan, Minnesota 55122-1897 (612) 681-4675 SITE ADDRESS: 1345 TOWERVIEW RD LOT: 4 BLOCK: 2 LEMAY LAKE HILLS P.I.N.: 10-44650-040-02 DESCRIPTION: Building Permit Type DECK Building Work Type NEW Census Code 434 ALT. RESIDENTIAL REMARKS: PLAN REVIEWED BY JOE VOLES FEE SUMMARY: Base Fee $50.00 Surcharge $.50 Total Fee $50.50 PERMIT TYPE: BUILDING Permit Number: 032147 Date Issued: 06/04/98 CONTRACTOR: i L OWNER: - Applicant - WARFIELD BOBBY J 1345 TOWERVIEW RD EAGAN MN 55121 (612)995-5142 I hereby acknowledge that I have read this application and state that the information is correct and agree to comply with all applicable State of Mn. Statutes and City of Eagan Ordinances. APPLICANT/PERMITEE SIGNATURE ISSUED B . S G ATURE A New Construction Requirements CITY OF KAGAN 3830 Pn OT KNOB RD - 55122 681-4675 ? 3 registered site surveys ? 2 copies of plans (include beam 6 window saes; poured intl. design; etc.) ? 1 energy calculations ? 3 copies of has preservation plan if lot planed after 7/1/93 required: _ Yes _ No DATE: 5 -?A-T? DESCRIPTION OF WORK: 1998 BUILDING PERMIT APPLICATION (RESIDENTIAL) RemodeVReoair Requirements V ? 2 copies of plan ? 2 site surveys (exterior additions d decks) ? 1 energy calculations for heated additions CONSTRUCTII IeU3 0 - STREET ADDRESS: It_34S IcxJe?(),2()J U LOT: _L? BLOCK: SUBD./P.I.D. #: 1-e o) T L LE, Hl I I S nn (1, / 996'-5141 t5 IV Name: Phone #: 4?I Z- 6J?- / ?? PROPERTY Last First OWNER ++ II T r _ 1 Street Address: ) `1 S I FX `) y t Y tJ J City 1EAC, 3 State: " l? Zip: 5S)2- ) Company: ?W Phone #: CONTRACTOR Street Address: /i? ?L 7 6 tT d (E- city State: ARCHITECT/ ENGINEER Company: Phone #: Registration #: Zip: Street Address: City Sewer S water licensed plumber (new construction only): and lot change is requested once permit is issued. I hereby acknowledge that I have read this application and sta State of Minnesota Statutes and City of Eagan Ordinances. OFFICE USE ONLY Certificates of Survey Received _ Yes Signature of Tree Preservation Plan Received Yes State: ?5b5° J Oc7` COST; a S License # Zip: . Penalty applies when address Chang J?% % OFFICE USE ONLY BUILDING PERMIT TYPE ? 01 Foundation ? 06 Duplex ? 02 SF Dwelling ? 07 4-plex ? 03 SF Addition ? 08 8-plex ? 04 SF Porch ? 09 12-plex ? 05 SF Misc. ? 10 _-plex WORK TYPE New ? 33 Alterations ? 32 Addition ? 34 Repair GENERAL INFORMATION Const. (Actual) (Allowable) UBC Occupancy Zoning # of Stories Length Depth APPROVALS Planning ? 11 Apt./Lodging ? ? 12 Multi Repair/Rem. ? ? 13 Garage/Accessory ? ? 4 Fireplace ? 15 Deck ? 36 Move ? 37 Demolition f 16 Basement Finish 17 Swim Pool 20 Public Facility 21 Miscellaneous Basement sq. ft. Main level sq. ft. sq. ft. sq. ft. sq. ft. sq. ft. Footprint sq. ft. Building Permit Fee Surcharge Plan Review License MC/WS SAC City SAC Water Conn. Water Meter Acct. Deposit S/W Permit S/W Surcharge Treatment PI. Park Ded. Trails Ded. Other Copies Total: MC/WS System City Water Fire Sprinklered PRV Booster Pump Census Code. SAC Code Census Bldg Census Unit Engineering Variance -lL Valuation: $ % SAC SAC Units } J I m r Nm°153ZW 14 Z. 00 N o J 9 Y 0 S."o ?/ O )/:0 8?1(f ?3 ?2A NACaE 0 + A,o e ro r /, _ 3o I° p j $ F --? 16 I o V o (D D ? o : o°',,,a X 4 A 4 w ul IO • N `8 Y -? u ?a N ` :o i a?P ° ,.«ea do ; a°1' ? e. 0 ?z/a ? ,+AG? An10 e c ? ao r? ? IB3.IZ. u CL '?' •I i N o??s' 3z: W 0 v m o P ? m D N Z a U r - o m D m o D n W 0 - { T N ?` o -F?'S9 E ?s5- 9 S EE: ^?T H nN TIL,Ty ?_ ? A its _..,;5 s4 59.E /G 0 A n ^ Y Ik i i 1 hereby certify that this is a corract reprssancation of • survey of: Luc 4, Block 2, LBMAY LAKe M1LI3, Dakota County, Miuuesota, according to the recorded plat thereof. and that this survey and cartlficato was prepared by m or under my direct supervision and that I am a duty registered Land surveyor under the laws of the State of Minnesota. 4? lacnbs + Beg'. No. 7714 Dated this 10th day of May, 1989 Elevations shown are existing grades and are city datum. Arrows denote proposed direction of surface water runoff. prnpeaad top of inundation - 909.8 Proposed garage flo,,r - 909.5 Proposed lowest floor - 9oh,0 Proposed finished grade at garage corners and front of house - 909.1 Proposed finished grade at rear of house - -)o).5 builder dud or owner to verify all proposed grades and grade the for su that the surface water does nut pond or create drainage problems for this lot or adjoining lob. R IE W D By Da a 3 EAGAN ENGINEERTM _ r,nnm I h I i CERTIFICATE OF SURVEY PREPARED FOR; Todd Phillips Box 13314 Minneapolis, W 55414 JACOBSON SURVEYORS LAKEVILLE, MN 55044 TEL. 469-4328 CITY USE ONLY LOT BL oC RECEIPT #: SUBD. /J RECEIPT DATE: 1996 MECHANICAL PERMIT (RESIDENTIAL) CITY OF EAfiAN 3830 PILOT KNOB RD EAGAN MN 55122 Date: Ilqg (612) 681-4675 ? ?! 9 Complete this section only if you are installing HVAC in single family, townhomes or condos under construction and not owner /occupied • HVAC: 0-100 M B T U $ 24.00 ADDITIONAL 50 M BTU 6.00 • Gas outlets ( minimum of one required @ $3.00 ea.) • State Surcharge: .50 • TOTAL: Complete this section only if you are remodeling, adding to, or repairing existing single family dwellings, townhomes, or condos. Note: Mechanical permit is not required for alteration/add-on to ductwork in existing residential units; but is required for the following: Install furnace Install air conditioning Install air exchanger, i.e. Vanee system, etc. Other Minimum fee applies to all remodel or add-ons of existing residences $ 20.00 State Surcharge 0 Total: $ 20.50 SITE ADDRESS: 134-7 TO W per' VI ° t W q OWNER NAME: 6o Ib. 11W c-f-7? c l o(? 11 ?? PHONE #: bff- 7/27 INSTALLER NAME: U?l)f1lPr.C S0LL`Irl,lde, a±j ruC'nC.ONE#: 4`3I 7b°lj STREET APDRESS: 55?a9 CITY: J9pte- Uall-CU STATE: Al zip: ?h-?2??? SIGNATURE OF PERMITTEE JS/FORMS BLD/MECH PERMIT (RES) - 1998 L BL SUBD. APPROVED BY: CITY USE ONLY INSPECTOR RECEIPT #: _ RECEIPT DATE: Please complete for DATE: 1998 MECHANICAL PERMIT (COMMERCIAL) CITY OF EAGAN 3830 PILOT KNOB RD EAGAN, MN 55122 (612) 681-4695 all commercial/industrial buildings multi-family buildings when separate permits are not required for each dwelling unit CONTRACT PRICE: WORK TYPE: NEW CONSTRUCTION INTERIOR IMPROVEMENT DESCRIPTION OF WORK: FEES: 1% of contract price OR $25.00 minimum fee, whichever is greater. Processed piping - $25.00 CONTRACT PRICE x 1% PROCESSED PIPING PERMIT FEE STATESURCHARGE TOTAL SITE ADDRESS: OWNER NAME: PHONE #: TENANT NAME (IMPROVEMENTS ONLY): INSTALLER: ADDRESS: PHONE #: CITY: ($.50 per $1,000 of permit fee due on all permits.) STATE: ZIP: SIGNATURE OF PERMITTEE .., CITY OF EAGAN EXTERIOR ENVELOPE AVERAGE 'U' COMPUTATION OWNER: SITE ADDRESS: 1,54S CONTRACTOR: 461 }r ?lr rQ DATE: IO- Z -$q PHONE: 19-7 Determine working square footage of each: 1. Total exposed wall area ... 7, 1 $ $ sq. ft. x .11 = 366,0 2. Total roof/ceiling area .. )513 sq. ft. x .026 31 3Y Total exposed wall area above floor = /YzY a. Total wall window area ............................ b. Total door area ................................... c. Total sliding glass area .......................... d. Total fireplace wall area ......................... e. Total wall framing area (average 10%) ............. f. Total net wall area above floor ................... g. Total rim joist area .............................. Total exposed foundation area = 21610 177, P1 37, 9z- Q Q(,-iUM nw,'S ;n W, S 5R,S0 /YZ, q 1007, Y /97 h. Total foundation window area ....................... IZO,LJ i. Total net foundation area above grade .............. 10Y0.6 Determine 'U' value of each wall segment: a. 121,9) x 'u' `13 = R3.&o b. 37. RZ x 'U' 13 _ 14192 c, x 'U' - d. x 'U' , OYS - e. x 'U' n9L f. x 'U' OY3 - g. /92 x 'U' 0YJ - h. x 'U! y) _ i. x 'U' Yo 3 . ................................................... Total = ZLO.3 7 If item 03 is the same as or less than item p1, you have met the intent of SBC 6006(c)2. Total exposed roof/ceiling area = %,$13 52, 4b j. Total skylight area ............................... _4 _ k. Total roof/ceiling framing area (average 10%) ..... __ 1. Total net insulated roof/ceiling area .............. 1B OVER Determine 'U' value for each roof/ceiling segment: .) x ' U' _ k. x 'U' 1. )5/3 x IU' , VZ3 = 4 . ...................................................... Total = 3 y,gC7 If total of 04 is the same as or less than #2, you have met the intent of SBC 6006(c)1. Alternate Building Envelope Design To utilize the total envelope system method, the values established by the sum of Items 03 and (14 shall not be greater than the sum of Items #1 and #2. 1. + 2. - 3. + i 4. - 2 SINGLE & DOUBLE FAMILY HOMES 1984 ENERGY CODE REQUIREMENTS On or about March 1, 1984, the following energy code requirements should be calculated and included with a building permit application. 1. Roof - ceiling assemblies - R-38 U = 0.025 Average 2. Exterior walls & rim joists - R-20 U = 0.11 Average 3. Floors over unheated spaces - R-20 U = 0.05 Average 4. Exterior overhangs will be considered as exterior wall. 5. Foundations (all exterior walls) - Minimum of R-5 insulation. 6. All insulated areas must be separated from the heated space by a well-lapped or sealed vapor barrier with a minimum perm rating of 0.1. A 4 mil. polyethlene sheet or equivalent meets this requirement. A Kraft face R-19 type insulation will be accepted in the rim joist areas. Air chute baffles are to be placed in every rafter space. P,. .. GUIDELIIIE TO (R) i'ACIURS FP.OII ASHRid MANUAL OF TYPICALLY USED PP.OOUCTS (R) (R) Interior Air Film (halls) 0.68 Gypsum or plaster board 3/8" 0.32 Exterior Air F11m (halls) 0.17 Gypsum or plaster board 1/2" 0.45 Interior Air Film (Vented Ceiling) 0.61 Gypsum or Plaster board 5/8" 0.56 Extcri,.r Air Film (Vented Ceiling) 0.61 Plywood 3/8" 0.4 Interior Air Film, (Ilcn Vented) 0.61 Plywood 1/2" 0.62 Exterior Air Film hlou Vented) 0.17 Plywood 3/4" 0,93 Sheathing, reg. density 1/2" 1.32 Aluminum Siding 0.61 Sheathing, reg. density 25/32" 2.06 Aluminum with Backer 1.82 Nail-base sheathing 1/2" 1.14 Aluminum with Backer L Foiled 2.96 1/2 x 8 Lao Sidinn (hood) 0.81 Built-up Roofs 0.33 7/16 x 12 Ilardhoard Siding 0.67 Asbestos-cement shinnlts 0.21 Asbestos Si Ainns 1/4 Lapped 0.21 Asphalt roll roofing 0.15 Stucco (or,.,,. and Finish Coat) --. Aspaalt Shingles 0.44 3/4" hood Subfloor or Sheathing 0.94 Insulation 2-2 3/4" Fiberglass 7.00 1/2" Plywood hoathinq 0.62 Insulation: 3 1/2" Fiberglass IF.DO 1/2" Particle Bu..rd 0.66 Insulation: 6" Fiberglass 19.00 WOODS: BLOW IIIG WOOLS Fir, pine L similar soft Woods 1 1/2" 1.89 Approx. 3" 9.00 2 1/2" 3.12 Approx. 4 1/2" 13.00 3 1/2" 4.35 Approx. 6 1/4" 1900 5 1/2" 6.87 Approx. 7 1/4" 24.00 Approx. 14" 30.00 Approx. 18" 4o.00 All other insulation materials must be Filled verified (R Factor) (R) Vermiculite 8" Concrete Block (S L G Reg.) 1.11 1.9; 12" Concrete Block (S L G Reg.) 1.28 3.15 ' 8" Light Weight 2.18 5.03 12" Light height 2.48 5.82 as>?na eta-aeee.: It*. e_nexa el NOTE: (U) x Area Square Feet qy l All Windows (w/Storns 1" to 4" Space) .56 Removal Double Glaring (ROG) .55 Thermo or welded 3/16" air space .69 1/4" air space .65 1/2" air space .58 (Other windows specifically tested can use better ratings) 1 3/4 Solid core door .46 w/storm, wood .31 w/storm, metal .26 Pease Steel Door Insl/I:/GL 7.458 .13 Stlding Glass Door, hood .65 Metal .715 CITY OF PAGAN / /- MINIMUM "U" VALUE AND R-FACTOR AT ROOF, WALL, RIM AND CONCRETE BLOCK ROOF J C:E 10J6 (Y-) VAL IQ lt1 jER(D? AlR Fll? 0 518" G-?P• P-D. Q (NSULA?1oN C4i . . OO EX?EtZ;oIC A1R FILC'I ' (STILL -? T°TAL (R)- WALL (_T?) VAL Q IN IEPIo(= AIfL FILM o. Ge O ILI GNrP•,BD., .'. ® ?? ?` if15ULATlor' Sias' Q9 25 ?jzR Yo17; ?J?c: MA `oNlTc S1Dir'(a u EX;;W-10t` AtFc FJUJ . i it . 1 l I V 2 - .(R) VALU: Alf, Fluff G S l?i iN5ULA71C,a 2 FICA Rtt?i ?Dje V n 105 Z-5sz :0'=7-i?47?5 . u• CSF;?r'ITE slob(; 0 ?-)7EAtID(L Aii; FILh Hull •Top..L (R)- fO:Jt?DATl?ti Ctz) VALU I3 IN TEI7lDi? Alrt FILt1 0 R-5 EX EI`loz Alit FILM uUu = ?/(Z= 'j", TONAL (Ct)= Floors over unheated spaces must have minimum R-factor'of R-20 (tuck-under garages). Floors over outdoor air (overhangs) must Have a minimum P.-factor of R-33. 11 SUBJECT: VARIANCE APPLICANT: BOBBY AND DENISE WARFIELD LOCATION: LOT 4, BLOCK 2, LEMAY LAKE HILLS 1345 TOWERVIEW ROAD - EXISTING ZONING: PD R-1, SINGLE FAMILY DATE OF PUBLIC HEARING: APRIL 18, 1989 DATE OF REPORT: APRIL 11, 1989 APPLICATION SUMMARY REPORTED BY: PLANNING AND ENGINEERING DEPARTMENTS An application has been submitted requesting a 10' Variance to the 30' front yard setback. The applicant is intending to construct a home and attached garage on lot 4, block 2, LeMay Lake Hills Addition. The proposed garage location would encroach 10'into the front yard setback area, a total of 281 square feet. Lots 1 through 3, block 2, LeMay Lake Hills, have not received front yard setback variances. Both lots in the Holmes Addition have received 10' variances to the front yard setback. Holmes Addition is located to the east of the parcel in this request. The applicant feels that, due to the steep grade on his property, it is necessary to move the building closer to the front property line, alleviating the burden of construction on the slope. The proposed house meets all other setback and building coverage requirements. If approved, this Variance shall be subject to all other Code requirements. ^??iV51iL l ONE AY; ?l•a > a J•%i` W n FO ?Ir ??t! II II PFD i 1 ' RD I m ••'I. ?\/222 } //J?Y1(? ?^.,,:. o i• . x X\ d 4 LEMAI ` 1 fpe ` ?r 6 1', ?. A T ?r RVI W t ROAD A q 7 ,. LU KA -?.., ...r, i e ADD TION _ t 3 »n +¢ T`E o„ u d A '... QUARRY J -ANE a ' AQ? "•1 'y,• 71 .•• r '?c? PARK ,>.11A I ' .1 '1 ''??J rte: •x 'n g?q`l u. ,?......• 0. `. q P, • i»:=, / rr,e •r? r fc, ?. I a p, L `r. e O 4 ¢ •? .r JFJ?1 YYY"' » ? ,r till' 74 , ? n,o ,> .,n ,r E ? p •': 6 e /? gin. •'• ••'a'•.. ,+ A•., . ' '.. sue- 444 , eu-1. nod {- ?? I i F , al\ {j a r1A r?? ¢ -nnn nu, CERTIFICATE OF SURVEY L o--F 4 u. t!rr•,.. r ti It I' ?1 11 d ,. r.,,..1 •.! ew .,r urnlor I^•c .!i r. ,: i ,it aii,I tin r I am a lu Iv rr•?i err!:'! l a?,,I curvev,r Undor tho IaIJS „i t1l, titah ,f tti lineaotta. !;I v I - r r r N SNbudc line Bic c K 2 9?\ _ X02, ri 4 .. _ - 41 ' S 1 VI ?- 2 J8 ? ,?oY wl 81-1 44• ZP:' - 85. LSO ... 9.8_aa << <E l=.' TowECZ?/«w RoAo 11 ?9,c P_ C'P. 9Y' ?LJ SCALE 1 :30 0 )EN( TES IRON MCt;. BEARIrJ3' ARE ASSUMED DATUM. PREPARE^ FOP: JACOEISON SURVEYORS r...Ill i,miiip, P, ox 1131"'. _aI?EVILLE, PAN 55044 ?linn capnlie, ?C: i15IA , PH,C)HE - 469-4328 4 4 Sy a ,it .0 N 28=8" ?t ? I ? I a I I I .I g" rGe lao(r tlmyul E f z4 / ¢. = /,o y 716ea n/ b.L. _101 s AV fSP_-- r .P I hereby cur* 8ma thi yWn tPecificadmy me of under tnT direel suD?w oad. that I am a duly gegistared I clonal -Engineer under the laws of the State of Kuihesot . n_//1 /J / Dcft r/I4Z,E.Q, rim *1 RLEXICO'RK sCHROUL[ MAM M, srm wsrArase _ /Vj,'So/u/7E SA& fADS : eXt:;O .G,F, 4" 3q2?? bAd 9 net. 8•HAK, 4- o 0- o - - - 8 ?kiAt? 244. _ -. -- . n PLEASE NOTE Yttmmomr otuwtues Apo ocmKmA m et1AN. asnotrt ar as wn.um= wnnt COPMTWM ew M CT Pm 7 teO zpj j ALL tfAT. AL %V M A" ` et7amUtm Cmf OIItTbwv 8 Off ttllOr atMMO wt ntsY IWVAL i AOGMTcx tATMY alOalls A!lMOVAL - -_- aaliVOt i - _n11 CIlatl ARCHli _. . l7CT COP17'RA?"T^o H/?/?1 vra7o-v MOLIN CONCRETE PRODUCTS CO. D Pitt- t?tw. ?.r?- uu.u..w..?? _ "? ?: Pair / a>f 2 l 8' FlExlCa/ee w/Z?CO.YCTb/°i? r .. . N AS &,o" • I an/e,.? « sole /SSVNr z .2 01^03r mac. ,. L, 3oo?los,' E aTrS?r I hereby certify that this plan, specification, or report was prepared by me or under my N direct supervision and that I am a duly Registered Professional Engineer under the laws of the State of Minnesota. Date 41,13 /?Oj Reg. No. B 3 ¢¢ -. I I . t w o" I I v )?toJ. Ggrayr G '? _ ? 13 4 T rOW" vAx w xL ..J -,- I 1 I _ ?¢Re bar =2=C d.a.l .-r ? . ? rC I onc I '_T _ Ynrn i- p?n I 1 I ? j -1- Q 21p. ' oo0?s; •a -- - - - ? e i ? ? ? ?_ mac- X i o ?? _ I _ J, L • •t ,• 1 _ _ e s - -?- - - -rt -- i -- - - - - - - - -- - I--- fi- -- - - r- ? - i - - - - -?- - YN B 0- F ti o 1 - - i I i ? Pjl ) A ' - - -{ - _ r 1 -i "Al i he ox.x reby po ceztzfy that th?plan? t w s..pxepazG. ?Y_LnC spd ? _oE ctitoaitpn, under_m ? ? ? ixpct j ' upgxvp on I and teat - i ai n a duiy d - I A g?stei a?vs o Engir eox 6d?xofessfana? nne of , the Slog o N un er e _ f j ;- -- - n - L- ` ?1 Dato (o /3/B 9 Re I i I g. No. ' 1 - I - - -- -? -`- -- - I ? - - - --------------------------------------------------------------PARTIALLY SHOWN SCREENS 26,29830 XINPNO03 D A K O T A 0 0 0 N T Y R E A L E S T A T E I N Q U I R Y N A M E/ A D D R E 8 S/ L E S A L PARCEL IDi 10 44900 020 01 SPECIAL HOMESTEAD CARD ENTEREDe FIRST DIVISIONi LAST DIVISIONi FEE CURRENT OWNERi MARSIE L OTIS 1743 YANKEE DOODLE RD PLAT NANEi LETENDRE ADDITION 02 16 1969 EAOAN MN 53121 TRANSFER TO SCREEN NUMEERs PFB-SCROLL FORWARD LESAU LOT 2 BLK 1 SUBJ TO HWY ESMNT OVER 8 SO FT 2 1 ALSO ? q6-00 22y56 2006 RESIDENTIAL BUILDING PERMIT APPLICATION > 6 vz) City Of Eagan 3830 Pilot Knob Road, Eagan MN 55122 CIA- Telephone # 651-675-5675 FAX # 651-675-5694 i New Construction Requirements Remodel/Repair Requirements Office Use OnN 3 registered site surveys showing sq. it of lot, sq. ft. of house; and all roofed areas 2 copies of plan showing footings, beams, joists Cart of Survey Recds (20% maximum lot coverage allowed) 1 set of Energy Calculations for heated additions Soils Report.` art.`'= Y;'? ?nN 1 Soils Report if proposed building is to be placed on disturbed soil '1 site survey for additions & decks Tree Pres PIan_R`( dSr V_77Y,-,, 2 copies of plan showing beam & window sizes; poured found design, etc. Addition • indicate If onsRe septic system Thiii`PreiRequit "ad' ; aV Y'`I"-? N 1 set of Energy Calculations 3 copies of Tree Preservation Plan if lot platted after 711193 Rim Joist Detail Options selection sheet (buildings with 3 or less units) Minnegasm mechanical ventilation form Obs'ite Septic Systerpi'1,': N Date Construction Cost ?) Z 3 ? Site Address 17'I ) Towei view R- Unit/Ste # Description of Work /P TC a Iv p 7 F f k2 > 06 Multi-Family Bldg - Y - N Fireplace(s) _ 0 - 1 _ 2 / Property Owner t)6 b4 (Na. ?",p I Telephone # (& S I) SO 3 - 77 $ 2 ??/G/7 Gy CCfd'(? GG/7 s G Contractor L??C/C?d Q Address ? " 1 1 / City 5-/? ??C_4LlZk - State Zip hj_6e' i ?V Telephone # (//137) -i 31;1 y3 ? o COMPLETE THIS AREA ONLY IF - Minnesota Rules 7670 Cateeor¢-1 Energy Code Category . Residential Ventilation Category 1 Worksheet (J submission type) Submitted i . Energy Envelope Calculations Submitted A NEW BUILDING _ Minnesota Rules 7672 New Energy Code Worksheet Submitted in the last 12 months, has the City of Eagan issued a permit foF a similar plan based on a master plan? - Y - N If yes, date and address of master plan: Licensed Plumber Mechanical Contractor Sewer/Water Contractor Telephone #( Telephone #( Telephone #( I hereby apply for a Residential Building Permit and acknowledge that the information is complete and accurate; that the, work will be in conformance with the ordinances and codes of the City of Eagan and the State of MN Statutes; I understand this is not a permit, but only an application for a permit, and work is not to start without a permit; that the work will be in accordance with the approved plan in the case of work which requires a review and approval of plans. j l?lA Aire Applicant's Pri ted Name Applic is Signature CASH RECEIPT tfTY OF*EAGAN ' 3830 PILOT KNOB ROAD • EAGAN, MINNESOTA 555.122 DATE 19 RECFHEO FROM AMOUNT (? ?'r" ' C G & DOLLARS O CASH CHECK 1 ??- BV C my- copy YONow-POW9 Copy Thank You BLDG. PERMIT NO. 01-3210 ?.. 01-3422 01-3445 01-3446 01-2155 75-3860 20-2275 20-3865 I' 20-3868 20-3716 i 20-2252 20-3713 20-3743 79-3866 28-3855 Bldg. Permit Plan Check Surch./Adm. SAC/Adm. Surcharge Road Unit SAC Water Conn. Water Trmt. Water Meter Acct. Dep. Water Permit Sewer Permit Sewer Conn. Park Ded. TOTAL C t) uu J,. CASH RECEIPT CITY OF EAGAN 3830 PILOT KNOB ROAD EAGAN, MINNESOTA 55122 s WN® FROM j-, AMOUNT $ 6 DOLLARS 100 ? CASH CHECK ron -, FUND OBJECT Thank You BY AMOUNT )t.; r-l ? C' i \ Whh*-Payws Copy vdow- kotft Copy Pb*--Fls Copy PERMIT City of Eagan Permit Type:Building Permit Number:EA147422 Date Issued:01/08/2018 Permit Category:ePermit Site Address: 1345 Towerview Rd Lot:4 Block: 2 Addition: Lemay Lake Hills PID:10-44650-02-040 Use: Description: Sub Type:Fireplace Work Type:Gas Insert Description: Census Code:434 - Residential Additions, Alterations Zoning: Square Feet:0 Occupancy: Construction Type: Comments:Improvements to the home may require smoke detectors in all bedrooms. Chimney / flue must be inspected prior to concealing. Carbon monoxide detectors are required within 10 feet of all sleeping room openings in residential homes (Minnesota State Valuation: 3,000.00 Fee Summary:BL - Base Fee $3K $88.50 0801.4085 Surcharge - Based on Valuation $3K $1.50 9001.2195 $90.00 Total: I hereby acknowledge that I have read this application and state that the information is correct and agree to comply with all applicable State of Minnesota Statutes and City of Eagan Ordinances. Contractor:Owner:- Applicant - Bobby L Warfield 3911 Valley View Dr Eagan MN 55122 Fireside Hearth & Home 2700 Fairview Ave N Roseville MN 55113 (651) 633-2561 Applicant/Permitee: Signature Issued By: Signature PERMIT City of Eagan Permit Type:Plumbing Permit Number:EA151029 Date Issued:08/06/2018 Permit Category:ePermit Site Address: 1345 Towerview Rd Lot:4 Block: 2 Addition: Lemay Lake Hills PID:10-44650-02-040 Use: Description: Sub Type:Residential Work Type:Replace Description:Water Heater Meter Size Meter Type Manufacturer Serial Number Remote Number Line Size Comments:Please call Building Inspections at (651) 675-5675 to schedule a final inspection. Allow an 18" minimum radius clearance to the water meter from all appliances (i.e. furnace, water heater, water softener). Fee Summary:PL - Permit Fee (WS &/or WH)$59.00 0801.4087 Surcharge-Fixed $1.00 9001.2195 $60.00 Total: I hereby acknowledge that I have read this application and state that the information is correct and agree to comply with all applicable State of Minnesota Statutes and City of Eagan Ordinances. Contractor:Owner:- Applicant - Bobby L Warfield 3911 Valley View Dr Eagan MN 55122 (651) 353-5546 Genz Ryan Plumbing & Heating 2200 West Highway 13 Burnsville MN 55337 (952) 767-1000 Applicant/Permitee: Signature Issued By: Signature